1. FIRST Valve Assembly Operating Instructions    FIRST Valve Assembly Components    e  566475 24V double solenoid valve    VUVG L10 B52 T M7 1P3  1 pc   e  183740 push pull fitting  M5 thread     QSM M7 1 4 1 U M    3 pcs   e  566716  e box     VAVE L1 1H2 LR    2 pcs     e  566654  1 2 meter cable     NEBV H1G2 KN 0 5 N LE2  2 pcs     Basic Valve Data   The VUVG L10 B52 T M7 1P3 is a 5 2 dual solenoid piloted valve  The valve has M7 ports and is  operated with a 24V DC signal  The maximum air flow is 13 4 cfm  The weight of the valve including the  fittings and cables is 0 2 lbs      183740     push pull fittings  3pcs     mM       3    Typical Pneumatic Connection  The pneumatic connection for  typical cylinder would be as  follows        1         t     a    Port 4      To cylinder back end   insert fitting here    Port 2      To cylinder front end   insert fitting here     Port 5     Exhaust from port 4                  gt    to atmosphere    Port 1      Pressure supply   insert fitting here     Port 3     Exhaust from port 2   to atmosphere     VIVEAGA AMIR     Electrical Connection  Connect the e box   s  seperate component VAVE     to  each end of the valve as shown in the picture below   After this connection is secured connect the supplied  cables to the connectors  Attached one end of each cable  to a 24V DC signal and the other to a OV DC signal   When the valve is switched on the LED will turn on     Wiring   Red   24V DC  Black  OV DC    Operation   To extend the c
2. ylinder activate coil 14 for at least 30 mSec  To retract cylinder ativate coil 12 for at least  30 mSec  Following the activation time the coil can be deactivated without switching positions  Verify  that both coils are not activated simultaneously  A minimum of 25 psi should be supplied Port 1     Manual Override   To operate the valve without electrical current depress the blue button for a temporary time or depress  and turn to maintain the activation  The valve will not return to original state unless it receives an  electrical signal at the coil or manual override operation     FESTO    Festo Corporation    For ordering assistance  or to find  your nearest Festo Distributor   Call  1 800 99 FESTO   Fax  1 800 96 FESTO   Email  customer service us festo com  Visit  www festo com us    For technical support   Call  1 866 GO FESTO  Fax  1 800 96 FESTO  Email  product support us festo com    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Visor LCD  SHM-NPR and SHM-NPR/RJ    CLIMAFLEX® STABIL    Trident Aegis  Radio SD MP3 WMA Canberra SD27 Melbourne  CNC PILOT 4290 Asse B e Y  Niles Audio NILES C5-VGA User's Manual  Respirator ABV - Intensive - Frank`s Hospital Workshop    Copyright © All rights reserved. 
   Failed to retrieve file