Home
INSTALLATION MANUAL NOTICE D'INSTALLATION
Contents
1. SELF CONTAINED ICE MAKER FM 120EE MACHINE A GLACE A BACINTEGRE FM 120EE N EISBEREITER MIT EINGEBAUTEM VORRATSBEH LTER CM 110EE IJSMACHINE MET INGEBOUWDE BUNKER FM 120EE 50 MAQUINA DE CUBITOS DE HIELO AUT NOMA FM 120EE 50 N MACCHINA PER LA PRODUZIONE DI GHIACCIO AUTOCONTENUTA FM 80EE FM 80EE N INSTALLATION MANUAL NOTICE D INSTALLATION INSTALLATIONSANLEITUNG INSTALLATIE VOORSCHRIFT MANUAL DE INSTALACION MANUALE PER L INSTALLAZIONE FOR QUALIFIED INSTALLER ONLY RESERVE AL INSTALLATEUR FUR DEN INSTALLATEUR VOOR DE BEVOEGDE INSTALLATEUR SOLAMENTE PARA INSTALADOR CUALIFICADO SOLTANTO PER INSTALLATORI QUALIFICAT 290177 Power Supply Cord IMPORTANT 1 In order to carry out safe and proper installation of the product please read this booklet carefully beforehand and follow the instructions contained within On completion of the installation start up the icemaker to check for any abnormalities and instruct the user on how to use and maintain the icemaker in accordance with the Instruction Manual This booklet should be handed over to the user after the installation and be preserved by the user together with the Instruction Manual for any further consultation that may be necessary WARNING The installation must be carried out by qualified personnel in accordance with current regulations according to the manufacturer s instructions 1 UNPACKING WARNING Children should not
2. 35 Operation of the icemaker for extended periods outside of these normal temperature ranges may affect production capacity 2 The icemaker should not be located next to ovens grills or other high heat producing equipment ENGLISH 3 The location should provide a firm and level foundation for the equipment 4 Allow 15 cm clearance at rear sides and top for proper air circulation and ease of maintenance and or service should they be required 5 This appliance is not suitable for installation in an area where a water jet could be used and where dripping is not allowed 6 Do not place anything on top of the icemaker or in front of the Louver 7 This icemaker will not work at subfreezing temperatures To prevent damage to the water supply line drain the icemaker when air temperature is below zero see Il 2 PREPARING THE ICEMAKER FOR LONG STORAGE in the instruction manual 8 The noise from this icemaker is 55 dB or less 3 INSTALLATION Incorrect installation can cause harm to people animals or things for which the manufacturer cannot be held responsible 1 Position the icemaker in the selected permanent site 2 Level the icemaker in both the left to right and front to rear directions by adjusting the legs 4 ELECTRICAL CONNECTIONS WARNING THIS APPLIANCE MUST BE EARTHED This icemaker requires an earth that meets the national and local electrical code requirements To prevent possib
3. a Water Reservoir will fill b Gear Motor will start c Compressor will start IMPORTANT 1 Check the conditions and quality of the ice production Do not use ice produced in the trial run It might be contaminated with foreign matter in the water circuit Discard or flush down the drain Clean the Storage Bin before use see Ill 1 CLEANING in Instruction Manual 7 FINAL CHECKS 1 Is installation free of water leaks 2 Is the icemaker free from vibration 3 Are all the panels fixed and secure 4 Has the user been instructed on correct machine use and handed the Instruction Manual HOSHIZAKI HOSHIZAKI EUROPE LTD UNIT A STAFFORD PARK 18 TELFORD SHROPSHIRE TF3 3DJ ENGLAND PHONE 01952 291777 92E2EB20B 050321
4. ation site not be suitable for the plug supplied with your product the plug must be removed cut off if it is moulded on plug and an appropriate plug fitted If the non rewirable plug has been cut from the power supply cord it must be disposed of There should be no attempt to reuse it Inserting such a plug into a socket elsewhere presents a serious risk of electrical shock The non rewirable plug must never be used without a fuse cover being fitted The correct replacement for the detachable fuse cover is identifiable from the manufacturer s reference number stamped on the plug Supply of replacement fuse covers can be obtained from Hoshizaki Parts Service Centres Fuses should be rated at 13A and approved to BS 1362 5 WATER SUPPLY AND DRAIN CONNECTIONS For the U K only the connections must be in accordance with current requirements of the Model Water Byelaws 1986 SI No 1147 Only potable water should be used for the icemaker Water supply pressure should be minimum 0 5 bar and maximum 8 bar If the pressure exceeds 8 bar use a proper pressure reducing valve Do NOT throttle back the supply tap Aplumbing permit and services of a licensed plumber may be required in some areas The icemaker drain is gravity flow so ensure drain pipe has an adequate pitch or fall Water should drain into an open trap 1 Attach angled end of white flexible inlet hose accessory to the G3 4 fitting at the to
5. be allowed in reach of the packaging elements plastic bags and expanded polystyrene as they are potential sources of danger CAUTION Remove shipping carton tape s and packing If packing material is left in the icemaker it will not work properly mw Wi WW WW iw Front Panel Left p KUIN IWIWWWWW i WAWWW Fl Air Filter Fig 1 Front Cover AT ENGLISH 1 After removing the packaging make sure that the icemaker is in good condition If in doubt please do not use the equipment but apply to professionally qualified personnel 2 Remove the shipping tape holding the Door and Front Panel 3 Open the Door take out the package containing accessories and check the contents a Installation Kit Inlet Hose Outlet Hose Adjustable Leg b Scoop P 4 Remove the Front Panel Left and Top Panel See Fig 2 5 Remove the protective plastic film from the panels If the icemaker is exposed to the sun or to heat remove the film after the icemaker cools Top Panel Protective Plastic Film Front Panel Left Adjustable Leg Front Panel Left Remove the screws Lift up and pull toward you Top Panel Remove the screws and lift up Fig 2 2 LOCATION IMPORTANT 1 This icemaker is not intended for outdoor use Normal operating ambient temperature should be within 5 to 40 Normal operating water temperature should be within 5 to
6. le severe electrical shock to individuals or extensive damage to equipment install a proper earth wire to the icemaker Remove the plug from the mains socket before any maintenance repairs or cleaning is undertaken This icemaker must have a separate power supply or receptacle of 220 240V The main control box circuit breaker is rated at 6A and should only be replaced by a qualified service engineer Usually an electrical permit and services of a licensed electrician are required If the supply cord and the plug should need to be replaced it should only be done by a qualified service engineer For the U K and the Republic of Ireland only The wires in the mains lead are coloured in accordance with the following code Green amp Yellow Earth Blue Neutral Brown Live As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured Green and Yellow must be connected to the terminal in the plug which is marked with the letter E or by the symbol L or coloured Green or Green and Yellow The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red Should the socket outlets in the install
7. p rear of the icemaker as indicated ensuring rubber sealing washer is correctly positioned Hand tighten sufficiently to provide leak free joint 2 Attach the other end of inlet hose to the water tap noting washer is correctly positioned before hand tightening as above 3 Attach grey flexible outlet hose accessory to the R3 4 fitting at the bottom rear of the icemaker as indicated confirming fitment of rubber washer before finally hand tightening the joint This pipe can be cut to length as necessary to suit position of main drain Water Supply Inlet G3 4 Inlet Hose Drain Outlet R3 4 ENGLISH Water Supply Tap 9 Inlet Hose Fig 4 6 START UP PROCEDURE 1 Check that the power supply cord is disconnected 2 With the Front Panel Left removed check that the Operation Switch on the Control Box is turned on Front Panel Control Box Left Condenser Air Filter Fig 5 Circuit Motor Operation Breaker 6A Protector Switch RCUIT MOTOR OPERATION BAKER PROTECTOR SWITCH Ay G ON OFF Bx G Control Box amp 3A FM 120EE CM 110EE 1A FM 80EE Fig 6 3 Replace the Front Panel Left and Top Panel in their correct position 4 Open the water supply tap ENGLISH 5 Connect the power supply and energise 6 The following should occur in sequence