1. 1 7 1 Introduction 1 5 Online manual On the NBMS hardware documentation CD R59770184 this manual R59770204 can also be found in electronic form Insert the NBMS hardware documentation CD R59770184 in the CD ROM drive of your PC If autorun is enabled on your computer the start page of the CD comes up If the CD does not start automatically use Win dows Explorer to open the file index htm from the CD Follow the links to the documentation of the NGC 105 and choose the related documentation Acrobat Reader can be used to view R59770204_XX_owners pdf Adobe Acrobat Reader is free and freely distributable software that lets you view and print Adobe Portable Document Format PDF files If Acrobat Reader is already installed the manual can be viewed just by a click on the link Else the Acrobat Reader must be installed first Its setup program can be found on the CD in section 3rd party tools The NBMS hardware documentation CD provides also access to the individual user s manuals of the NGS boards and further NBMS documentation Barco NGC 105 R59770204 Revision 01 October 2008 1 8 2 Summary 2 Summary This chapter gives an overview about the features of NBMS in general and NGC 105 in particular Barco NGC 105 R59770204 Revision 01 October 2008 2 4 2 Summary 2 1 Properties Barco s Networked Broadcast Monitoring System NBMS enables operators to monitor their broadcast processes and visualize video
2. after startup indicates a defective component or a component with critical operating condition green operating F1 F5 numbering of the NGS processing boards PSU1 2 slots 1 and 2 for power modules Figure 3 2 Front view of NGC 105 with open front flap Barco NGC 105 R59770204 Revision 01 October 2008 3 3 3 The device and its components 3 1 2 The rear ATTENTION 6a b Fan module 1 2 with ventilation grille for board cooling airflow is from front to back 7a b Mains connection for PSU1 PSU2 with cord retaining strain relief 8 connection for equipotential bonding conductor 9 ventilation grille for power supply cooling airflow is from front to back ShMg SMC 101 optional R1 R5 rear slots for connection boards Figure 3 3 Rear view of NGC 105 To protect NGC 105 from overheating the air supply openings in the case shall be kept free of obstructions To disconnect the NGC 105 from the power supply all power cords have to be pulled of the mains connections 7 The back panel has to be easily accessible To ensure power redundancy take care to connect each two power modules to an independent power net The connection board slots There are 5 slots for connection boards at the rear side of NGC 105 R1 R5 They are numbered from bottom to top A corresponding label is printed on the device Slots which are not equipped with connection boards are covered by a bracket In th
3. at the handle 2 Picture 2 below Take a new fan module out of its packaging Take care of the orientation of the fan module Fan module 1 must be rotated until knurl screw and handle are on the upper part of the fan module Fan module 2 must be rotated until knurl screw and handle are on the lower part of the fan module Push the fan module carefully into the slot until the front sheet of the fan touches the sheet of the housing Fasten the knurl screw until it is tightened If an SMC 101 is used check that the LED 3 of the fan is off indicating normal operation and that the status LED at the front shines green again Figure 5 4 Two steps to exchange a fan module Barco NGC 105 R59770204 Revision 01 October 2008 5 6 5 Maintenance 5 3 Cleaning 5 3 1 Ventilation pads The dust filters consist of fine metal mesh These filters cannot be exchanged but are meant to be cleaned with a vacuum cleaner from time to time There are two procedures to clean the filters The first procedure can be chosen if it is possible to have a vacuum cleaner at the NGC 105 The second procedure explains how to remove the front cover and take it away for cleaning Vacuum cleaning the filters on the device If the device is not operating while being cleaned the front flap can simply be cleaned with the vacuum cleaner During operation there is strong suction on the filter mesh Therefore the flap must be opened to remove the suction o
4. cccccscssscsescscscscscscsesesssesesesesscscecscscsescsesesesssaaacaeseees 5 5 5 2 2 Exchanging the defective fan MOdUIe ce ccescccccssssesescscscscscsesesesesesesesessssececsescsesesessssnssececseseaes 5 6 5 3 Clean e e uaa ua aad tie 5 7 5 31 Ventilation Pads iia a Bete 5 7 5 3 2 CADINC bitin a ado erat cb Tih 5 8 ACA n i a aa 6 1 reaL E Aa F e A E EEA 6 2 6 2 Older codecs alaba 6 3 7 Troubleshooting ala 7 1 TA Ea E e NA 7 1 SS Taa LEY A OO 8 1 Barco NGC 105 R59770204 Revision 01 October 2008 vi 1 Introduction 1 Introduction This chapter explains the structure of the manual itself and the used typographic styles and symbols Safety in formation is provided concerning the operation of computer systems from Barco Barco NGC 105 R59770204 Revision 01 October 2008 1 1 1 Introduction 1 1 Application and target group This documentation is aimed for operators of NGC 105 devices 1 2 How this manual is organized This manual describes design and operation of NGC 105 from Barco It is divided into eight chapters Introduction explains the structure of the manual itself and the used typographic styles and symbols Safety information is provided concerning the operation of computer systems from Barco Summary gives an overview about the features of NGC 105 The device and its components describes the look of NGC 105 and its components Operating explains the operation of NGC 105 Mai
5. controller controller controller ES Workstations with LAN Network switching Workstations E Central server o al E a NGC 105 with NGS input boards Sources Figure 2 1 NBMS architecture with NGC 105 for input modules Barco NGC 105 R59770204 Revision 01 October 2008 2 3 3 The device and its components 3 The device and its components This chapter describes the setup of the NGC 105 Barco NGC 105 R59770204 Revision 01 October 2008 3 1 3 The device and its components 3 1 NGC 105 3 1 1 The front 1 power switch status LED only operable with SMC 101 off power switched off red during startup while SMC 101 is still booting after startup indicates a defective component or a component with critical operating condition green operating 3 vision panel giving view to the status LED s of the NGS processing boards 4a air supply for power supply airflow is from front to back 4b air supply for boards cooling airflow is from front to back 5 fixation screws for front flap F1 F5 numbering of the NGS processing boards Figure 3 1 Front view of NGC 105 Barco NGC 105 R59770204 Revision 01 October 2008 3 2 3 The device and its components With the front flap opened the device looks like the figure below or similar 1 power switch status LED only operable with SMC 101 off power switched off red during startup while SMC 101 is still booting
6. occurs this causes the status LED at the front to shine red until the reason for the alarm is resolved In case of a major alarm i e the status LED at the front shines red and the LED major alarm at the SMC 101 shines red the following should be checked 4 2 1 Housing fans The LED s at the fan modules are off if they are working properly If a fan spins too slowly or fast or if it is bro ken then its LED shines red and you have to replace this fan please refer to section 5 2 Replacing Fans 4 2 2 Processing boards of NGS xxx Look at status LED L1 at the processing board please refer to Figure 3 4 e A major alarm of an NGS xxx changes the state of the LED L1 to red In case of a major alarm contact instruct authorized personnel to check whether the board needs to be ex changed or not and in case to exchange it 4 2 3 Power modules Each power module has two LEDs Both LEDs should shine green If this is not the case i e one or both are off then please refer to section 5 1 Replacing power modules 4 2 4 SMC 101 The status LED L1 of the SMC 101 does not indicate a critical state of the board like the status LEDs L1 for the processing board do but it shines red when the board is not in its proper operating state e g during boot up If the boot process has been stopped somehow or other then it might be necessary to reboot the SMC 101 This can be done in two ways e If the operation of the NGC 105 may be interrupted t
7. remove the power module The cover of the power module is been used as heat sink for cooling usually the temperature is around 50 60 Celsius under full operation While exchanging a power module at a running NGC 105 the other power modules must remain in operation to ensure operation e Open the front flap by unscrewing the screws 5 on the top of the front please refer to Figure 3 1 Front view of NGC 105 e Locate the defective power module by examining the Z Ds 1 2 on the individual power modules please see above e Remove the defective power module by pulling at the handle 3 e Take a power module with the order number r9832282 or R9861200 out of its packaging Make sure it is a power module of type Unipower TPCM3000 Z 1107 e Take care of the orientation of the power module please refer also to the pictures above The handle bar must be more to the right and the LED s must be on the top e Push the power module carefully into the slot e The power module must be inserted unless the handle bar is so far inside the device that the front flap can easily be closed The closed front flap serves to fix the power module Press the power module firmly into its slot e Check that both Ds 1 2 shine green e Check that the status LED 2 at the front of the NGC 105 shines green again e Close the front flap again and tighten the screws 5 working well the status LED will also turn to
8. symbol there is a risk of damage to parts which are sensitive towards electrostatic charge Or If you do not heed instructions indicated by this symbol there is a risk to get harmed by sharp objects FA If you do not heed instructions indicated by this symbol there is a risk that parts may explode If you do not heed instructions indicated by this symbol there is a risk that hot parts impact persons or objects D The sheet icon indicates additional notes A Next to this icon you find further information This icon marks tips Next to this icon you find important notes HO Barco NGC 105 R59770204 Revision 01 October 2008 1 3 1 Introduction 1 4 Safety instructions This section describes safety precautions which must be observed when installing and operating a product from Barco 1 4 1 Standards Safety regulations NGC 105 is built in accordance with the requirements of the international safety standard IEC 60950 1 UL 60950 1 and CSA 22 2 No 60950 1 06 which are the safety standards of information technology equipment including electrical business equipment These safety standards impose important requirements on the use of safety critical components materials and isolation in order to protect the user or operator against the risk of electric shock and energy hazard and having access to live parts Safety standards also impose requirements to the internal and external tempe
9. EMA 5 15 plug Power cord with GB 2099 plug The wires of the power cord are colored in accordance with the following code yellow green Earth Ground blue Neutral brown Line Live Figure 1 3 GB 2099 plug 1 5 Barco NGC 105 R59770204 Revision 01 October 2008 1 Introduction e Do not allow anything to rest on the power cord Do not locate this product where people will walk on the cord To disconnect the cord pull it out by the plug Never pull the cord itself e If an extension cord is used with this product make sure that the total of the ampere ratings on the products plugged into the extension cord does not exceed the extension cord ampere rating e Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock e Never spill liquid of any kind on the product Should any liquid or solid object fall into the cabinet unplug the set and have it checked by qualified service personnel before resuming operations e Lightning For extra protection for this video product during a lightning storm or when it is left unattended and unused for a long period of time unplug it from the wall outlet This will prevent damage to the unit due to lightning and AC power line surges Due to high touch current the NGC 105 is intended to be used in a location having equipotential bonding e The bu
10. Figure 3 1 Front view of NGC 105 If an SMC 101 is used the status LED 2 at the front of the NGC 105 first shines red while the SMC 101 is boot ing When the SMC 101 is operable it shines green provided that there are no alarms in the system please refer to section 4 2 Alarms with SMC 101 The fans start spinning and the NGS boards start booting They require only short time to boot and initialize as soon as they are operable the status LED L1 on each board shines permanently green Switching off Switch the power switch on the front of NGC 105 to the O position to switch the device off please refer to Figure 3 1 Front view of NGC 105 Barco NGC 105 R59770204 Revision 01 October 2008 4 2 4 Operating 4 2 Alarms with SMC 101 If an SMC 101 is used in the NGC 105 then LEDs indicate a critical state of a component The LEDs are on the one hand the status LED 2 at the front of the NGC 105 which then shines red please refer to Figure 3 1 and on the other hand the alarm LEDs on the SMC 101 at the rear of the NGC 105 Further notification of alarms can be con figured on the SMC 101 please refer to the SMC 101 user s manual Alarms on SMC 101 The SMC 101 knows three different alarm states minor alarms major alarms and critical alarms For each of these states there is an LED on the SMC 101 to indicate this alarm With default configuration of the SMC 101 only two of them are used minor and major alarms If an alarm
11. TRM La PE Ni TT DARAT oo Ea E 04 Number Interface LED assignment L1 LED status green board status OK red critical operation state over temperature voltage out of range or board failure with the need to exchange it N1 RJ45 connector stream net net 1 N2 RJ45 connector stream net net 2 Figure 3 4 Location of general interfaces on processing board top and connection board bottom Barco NGC 105 R59770204 Revision 01 October 2008 3 5 3 The device and its components 3 3 SMC 101 shelf management module The shelf management module SMC 101 is an optional board to control the working of the NGC 105 and for board management of all additionally inserted NGS xxx boards It is accessible on the rear of NGC 105 For detailed information on usage and technical specifications of the SMC 101 please refer to the user manual see section 1 5 Online manual 3 3 1 General interfaces and control elements The SMC 101has multiple LEDs at its front panel The LED far right is the status LED The connection board is in the upper part equipped with board specific connectors In the lower part at the very bottom there are two RJ45 connectors for the connection to a redundant network They are labeled MANAGEMENT 11 Barns 8 E E Number Interface LED assignment L1 LED status green SMC 101 is running red SMC 101 is not running e g during boot up N1 RJ45 connector stream ne
12. User s manual NGC 105 R59770204 Current Version Title NGC 105 User s Manual ID no R59770204 Revision 01 Date October 2008 Main issue update chapter 1 chapter 2 chapter3 add chapter 4 add chapter5 add chapter 6 chapter 7 corr chapter 8 new The corresponding chapters are new or completely revised corr Passages of the corresponding chapter were corrected see modification bars add Passages of the corresponding chapter were added see modification bars This manual refers to the following hardware NGC 105 R9832305 Document History Modifications which result in a new version are indicated by a vertical bar Barco NGC 105 R59770204 Revision 01 October 2008 Trademarks Brand and product names mentioned in this manual may be trademarks registered trademarks or copyrights of their respective holders All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products or their manufacturers Copyright 2008 by Barco Die Weitergabe sowie die Vervielf ltigung aller Unterlagen die von uns berlassen werden deren Verwertung und Mitteilung ihres Inhaltes an Dritte ist nicht gestattet soweit dies nicht ausdr cklich zugestanden ist Urheberrechte insbesondere auch solche an Software werden nur insoweit bertragen als es f r die Erreichung des speziellen Vertragszwecks erforderlich ist Zuwiderhandlungen k nnen
13. a huge display wall to monitor hundreds of signals e The networked hardware platform may be divided into 3 physical components the source capturing units the interconnecting IP network with the central server and the display generating units All components are designed as standard rack mountable chassis e The BMS software package allows complete system control and is accessible from any system network con nection Barco NGC 105 R59770204 Revision 01 October 2008 2 2 2 Summary NGC 105 The NGC 105 is a 5 slot chassis capable to house all NGS type source capturing units The NGS boards capture the sources connected to them and convert them into streams These streams are fed to the video network and can be displayed on any NBMS display generation unit on the same network The NGC 105 provides 5 slots for NGS processing and connection boards 1 slot for optional SMC 101 shelf management module 1 or 2 power modules for standard or redundant power operation 2 fans all components are hot swappable extensive monitoring functions via the optional SMC 101 Production control and desktop workstations Master Control Audio control ae ain a E Display Display i P controller controller Display Display pa controller controller n A A e EE ee ee Display Display Display
14. al values e If you are not sure of the type of AC power available consult your dealer or local power company e This product is equipped with a 3 wire grounding plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the purpose of the ground ing type plug e This equipment must be grounded earthed via the supplied 3 conductor AC power cable If the supplied power cable is not the correct one consult your dealer Barco NGC 105 R59770204 Revision 01 October 2008 1 4 1 Introduction Mains lead AC power cord with CEE 7 plug The wires of the mains lead are colored in accordance with the following code yellow green Earth Ground blue Neutral brown Line Live Figure 1 1 CEE 7 plug Power cord with NEMA 5 15 plug e The cord set must be UL approved and CSA certified The minimum specification for the flexible cord is No 18 AWG Type SVT or SJT 3 conductor o e The cord set must have a rated current capacity of at least 10 A The attachment plug must be an Earth grounding type with a NEMA 5 15P 10 A 125 V configuration The wires of the power cord are colored in accordance with the following code green or yellow green Earth Ground blue or white Neutral brown or black Line Live Figure 1 2 N
15. at the appropriate quality for the viewing application without using bandwidth unnecessarily e Application management The extended metadata monitoring and alarming capabilities of NGC 105 enable proactive monitoring by ex ception Fault conditions on the incoming video and audio feeds can be detected and the operator can be no tified of these errors in a variety of ways The controller communicates the alarm to network management systems via Web services e Redundancy Redundant networking based on Ethernet technology duplication of the central processing machine and N 1 redundancy on the output modules when combined with dual input projection modules e Serviceability The NGC 105 comprises a rack mountable chassis featuring redundant power supplies and an optional SMC 101 shelf management module and is equipped with hot swappable auto sensing NGS input boards supporting both standard and high definition video feeds e High flexibility To distribute sources to any viewer from rear projection displays to PCs to enable remote monitor ing viewing System architecture Barco s NBMS solution consists of high quality rear screen projection modules or LCD panels a networked hard ware platform and a Broadcast Monitoring Suite software package e A single screen is capable of simultaneously displaying multiple sources together with related metadata audio metering information and computer applications Two or more modules can be combined into
16. condensing Table 6 1 Barco NGC 105 R59770204 Revision 01 October 2008 6 2 6 2 Order codes Documentation R59770204 R59770205 R59770184 Hardware R9832305 R9852467 R9852468 GBP 2688 21 Spare parts R9832295 R9832282 Barco NGC 105 R59770204 Revision 01 October 2008 user s manual NGC 105 English installation and service manual NGC 105 English NBMS hardware documentation CD ROM NGC 105 base unit dummy rear bracket dummy front board with bracket grounding kit spare fan module spare power module 650W 6 Technical appendix Table 6 2 6 3 7 Trouble shooting 7 1 Contact Helpdesk Feel free to contact us if you have any further questions e Barco N V Europe President Kennedypark 35 B 8500 Kortrijk Phone 32 56 262 350 Fax 32 56 233 013 E mail support smd barco com Web www barcocontrolrooms com 7 Trouble shooting 7 1 Barco NGC 105 R59770204 Revision 01 October 2008 8 Index 8 Index alarm handliMg oonononinininononononononononononononononoso 4 3 technical dina 6 2 cabinet NGS AA A Bae eas 5 8 CONNEC G nic icine ace 3 8 ClEANING rata das ees tate 5 7 connection bOaTdO oocconininininoninononononononononononos 3 5 calera at a E a 5 8 processing board 0 eeeeeccscscscsesesesssetseeteeeeeeees 3 5 A aa 5 7 online Manual siina a 1 8 ventilation Pads oonocinnononinonononononononononononoso 5 7 OldEl COdES alitas 6 3 connec
17. content in real time from anywhere in the facility This innovative solution allows high quality low latency distribution of video sources and metadata over an IP network towards multiple screens even in separate control rooms hereby offering ultimate flexibility for broadcast and distribution monitoring The distributed architecture of the Networked Visualization solution enables video content to be captured once in any location and distributed and displayed as many times as required in any location The system s extended metadata monitoring and alarm capabilities enable proactive monitoring by exception improving operational efficiency and reducing downtime The Networked Broadcast Monitoring System comprises e Anew network approach Networked Visualization breaks down the traditional AV equipment functionality and enables complete solu tions to be built using intelligent displays high performance encoders decoders and management and con trol software built on industry standard IT infrastructures This enhances the flexibility scalability and reach needed in today s broadcast environments at significantly lower costs e Network streaming Industry standard technologies and protocols including IP multicasting and JPEG2000 are used as far as pos sible JPEG2000 compression enables visual information to be scaled to the appropriate size for the display being used This means video signals can be streamed over the Ethernet network
18. e slot on the very top ShMg an SMC 101 can be used Otherwise it is also covered by a bracket Barco NGC 105 R59770204 Revision 01 October 2008 3 4 3 The device and its components 3 2 NGS XXX NGS boards are used to convert and encode video or data sources to JPEG2000 streams which are provided to the video network One NGS consists of a processing board which is visible on the front and of a connection board which is accessible on the rear The active processing board performs data conversion and provides visual feedback about the operation of the board by means of the LEDs on its front plate The passive connection board provides connectors for video input and streaming output For detailed information on usage and technical specifications of the NGS boards please refer to the individual user manuals see section 1 5 Online manual 3 2 1 General interfaces and control elements The processing boards have multiple LEDs at the front panel The number of the LEDs depends on the type of the NGS The LED far left is the status LED Its function is identical for all NGS types It also provides feedback on the operation the NGC 105 The connection board is on its right part equipped with board specific connectors In the left part at the very left edge there are two RJ45 connectors for the connection to the video net The exact position of these two connec tors may vary slightly on different NGS types They are labeled STREAM or S
19. eled STREAM or STRM Connect the plug STREAM NET1 to the stream network If redundancy is desired connect also plug STREAM NET2 to this network Please see the figure below HH Figure 3 7 Network connection Additional network connectors on a board labeled CTRL SERVICE or SRVC are intended for ser vice interactions and are not used in standard operation Do not connect them 3 5 2 Video and data connection Connection of video and data to the NGS connection boards depends on the type of the used board Please refer to the individual NGS XXX user s manuals see section 1 5 Online manual Barco NGC 105 R59770204 Revision 01 October 2008 3 8 3 The device and its components 3 5 3 Power supply NGC 105 is designed to operate with single phase power systems having a grounded neutral conductor To reduce the risk of electric shock do not plug into any other type of power system The NGC 105 must be connected to an equipotential bonding conductor 8 see Figure 3 3 Rear view of NGC 105 If it is not connected ask authorized personnel to establish the connection Check the power rating on the wall outlet before connecting NGC 105 to the wall outlet or to a power strip Contact the facilities manager or a qualified electrician if you are not sure what type of power is supplied to the building To connect the NGC 105 to the power supply follow the steps below e Make sure that the pow
20. enononunesuaune 1 1 1 1 Application and target GrOUP ccccccccscscscscscscscsesesesssssssssssscsssesesesesesesesssssesssecscscsssesesssauesasacseseseseseecseeees 1 2 1 2 How this manual is OGaniZed n a aa aa EE E a aieeaa 1 2 LS Styles and Symbol S ii a a a t A a a St 1 3 MASON UC enr i ee A a Shes ROS epee Rad ae eS 1 4 TAA Standa dS cessive cates RON 1 4 W422 PLEGAULIONS tiniest dite kien A halla o E ae kee eee 1 4 1 4 3 Unpacking Of devies cc ccceseseeseseesessssesescscscscscscsesesesssssssesscassssssesesesesesesssssesesesececscsesesesesasasaeaeaees 1 6 1A AllnstallatiO taa iaa 1 6 1245 SEI ic catas 1 7 T46 Cleaning at IE Sn eee Sete oa ee SS 1 7 MARE DaAGKIN irs as sacs sates t t ESE toa stat saeser otc ec DSi emcee Re sages E ese 1 7 15 Online Manal s ense E a en es ann beeen wads ae ees 1 8 D SUMMARY A O 2 1 A A de SUS TEs 2 2 3 The device and its coMponentsS sesesssessesesesessesesesessesesesesseseseesesessesesesessesesesessesesesessesesesesosseseseses 3 1 S31 NGGCTOS se A EN O E R E S ee E a e ion edt EE A a a 3 2 Ad RRE E oe OEE 3 2 BZ TM EEA A EA a E E EEATT 3 4 IX NGOS iia 3 5 3 2 1 General interfaces and control elements ccccscscsesescscscscscscsesesesssesasscassesesesesescsesessescececeteeseees 3 5 3 3 SMC 101 shelf management Module uu ceeeesesesesesessescscscscscscscsesesesssesssssasssasseseseseseseseseesessssasaaeeeseees 3 6 3 3 1 General interfaces and control elements ce cccc
21. er switch on the front is in the off position On the rear of NGC 105 there are two mains connections labeled PSU1 and PSU2 Each of which connects only to the corresponding power module Therefore for each equipped power module the corresponding mains con nection must be connected to a power supply e Plug the female end of the power cord into the mains connections at the rear picture 1 below e Fix the cord retaining strain relief Take care that it interlocks with the ribbing of the cable picture 2 below Figure 3 8 Mains connection e Plug the male end of the power cord into a power outlet To ensure power redundancy take care to connect the present power modules to independent power nets Barco NGC 105 R59770204 Revision 01 October 2008 3 9 4 Operating 4 Operating This chapter provides an instruction for the interactions you may do with the NGC 105 WARNING Operation actions not explained in this section bear the risk of electric shock If an operation action is needed that is not mentioned in this chapter instruct authorized personnel with it Barco NGC 105 R59770204 Revision 01 October 2008 4 1 4 Operating 4 1 Switching on and off The NGC 105 is set up configured and connected to the mains connection at your site by trained service person nel Switching on Switch the power switch on the front of NGC 105 to the I position to switch the device on please refer to
22. front flap and close it again Barco NGC 105 R59770204 Revision 01 October 2008 5 7 5 Maintenance 5 3 2 Cabinet Never clean the case of NGC 105 without first switching off the device and disconnecting all power supply cords Do not use liquid cleaners or aerosol cleaners Use a soft cloth to periodically clean the cabinet Stubborn stains may be removed with a cloth lightly dampened with mild detergent solution Never use strong solvents such as thinner or benzine or abrasive cleaners since these will damage the cabinet Unplug the device from the wall outlet before cleaning Barco NGC 105 R59770204 Revision 01 October 2008 5 8 6 Technical appendix 6 Technical appendix This chapter provides tabular overviews about the technical details of NGC 105 its components and of their inter faces Barco NGC 105 R59770204 Revision 01 October 2008 6 1 6 Technical appendix 6 1 Technical data NGC 105 chassis type 19 rackmount 5U dimensions h w d 222 mm 483 mm 509 mm 8 7 in 18 9 in 20 0 in dimensions h w d with handles 222 mm 483 mm 551 mm 8 7 in 18 9 in 21 7 in weight with standard power supply 19 kg 41 Ibs weigth with redundant power supply 20 kg 44 Ibs Power mains 100 240V 14 6A 50 60Hz power consumption 700 W inrush current standard power supply 1 x 30A redundand power supply 2 x 30A operating conditions 0 C to 40 C at max 80 humidity non
23. hen just switch the NGC 105 off and on again Thus rebooting the SMC 101 e If the operation of the NGC 105 may NOT be interrupted then instruct authorized personnel to remove the SMC 101 from the shelf and re insert it in order to initiate a reboot Barco NGC 105 R59770204 Revision 01 October 2008 4 3 5 Maintenance 5 Maintenance NGC 105 requires very little maintenance Some maintenance operations are nevertheless necessary to maintain distortion free operation of NGC 105 They can be done by means of the following descriptions WARNING Maintenance operations not explained in this section bear the risk of electric shock If a maintenance operation is needed that is not mentioned in this chapter instruct authorized personnel with it Barco NGC 105 R59770204 Revision 01 October 2008 5 1 5 Maintenance 5 1 Replacing power modules The power modules are hot swappable They are located behind the front flap The two slots for power modules are located on the upper part on the front of the NGC 105 There is a labeling next to each slot PSU1 and PSU2 indicating the number of the slot please see the figure below PSU1 PSU2 WARNING ress ihe poner supply Figure 5 1 Location and numbering of the slots for power modules The NGC 105 can get equipped with one power module for non redundant operation or with two power supplies for redundant operation In non redundant operation it is recom
24. ilding installation shall provide a means for connection to protective earth e The equipment is to be connected to that means e A service person shall check whether or not the socket outlet from which the equipment is to be powered provides a connection to the building protective earth If not the service person shall arrange for the installa tion of a protective earthing conductor from the separate protective earthing terminal to the protective earth wire in the building 1 4 3 Unpacking of devices Note advises on the packaging for unpacking 1 4 4 Installation Only authorized personnel may install the device e Use only the power cord supplied with your unit While appearing to be similar other power cords have not been safety tested at the factory and may not be used to power the unit For a replacement power cord contact your dealer e Slots and openings in the cabinet and the sides are provided for ventilation to ensure reliable operation of the unit and to protect it from overheating these openings must not be blocked or covered The openings should never be blocked by placing the product on a bed sofa rug or other similar surface This product should never be placed near or over a radiator or heat register This unit should not be placed in a built in in stallation or enclosure unless proper ventilation is provided e The maximum recommended ambient temperature for this equipment is 40 C e When using the unit i
25. ing Of oococococococococicnonananononononononononononononononos 4 2 O cooocococcococcoconcononcnononononnconononncnnononncnnos 3 8 SWitching OM dl 4 2 NGC 105 video MON ed lid 3 2 connect cidad 3 8 COMO Msn 3 3 vide NETWOKK sanien ins 3 8 POA EA T E E EIA 3 4 Barco NGC 105 R59770204 Revision 01 October 2008 8 1
26. m or independent services will be deemed invalid provided the damage is not proven to be attributed to the absence of properties quaranteed in writing or due to the intent or gross negligence on the part of Barco If the purchaser or a third party carries out modifications or repairs on good delivered by Barco or if the goods are handled incorrectly in particular if the systems are commissioned or operated incorrectly or if after the transfer of risks the goods are subject to influences not agreed upon in the contract all guarantee claims of the purchaser will be rendered invalid Not included in the guarantee coverage are system failures which are attrib uted to programs or special electronic circuitry provided by the purchaser e g interfaces Normal wear as well as normal maintenance are not subject to the guarantee provided by Barco either The environmental conditions as well as the servicing and maintenance regulations specified in this manual must be complied with by the customer Barco NGC 105 R59770204 Revision 01 October 2008 ill Revision sheet To e Barco Control Rooms GmbH An der Rossweid 5 D 76229 Karlsruhe Phone 49 721 6201 0 Fax 49 721 6201 298 E mail docu de bcd barco com Web www barcocontrolrooms com From Date Please correct the following points in this documentation R59770204 page wrong correct Barco NGC 105 R59770204 Revision 01 October 2008 Contents A unos oie non on
27. mended to use PSU1 for the power module This enables self evident cabling even though from technical point of view both slots are equivalent Barco NGC 105 R59770204 Revision 01 October 2008 5 2 5 Maintenance 5 1 1 Determining a defective power module If an SMC 101 is used with the NGC 105 then in case of the failure of a power module the status LED 2 at the front of the NGC 105 shines red please refer to section 4 2 Alarms with SMC 101 A defective power module can be determined by examining the LEDs at the power modules If a power module is operating well both LEDs at the front should shine green If this is not the case you can first check whether the mains connection of this power supply is connected to a wall outlet The corresponding mains connection on the rear of the device is labeled identically like the slot of the power supply If this connection is all right and the connected power net has not failed then the power supply is defective and must be replaced green LED AC power OK green LED DC power OK handle bar air supply openings hwWN Figure 5 2 Power module Barco NGC 105 R59770204 Revision 01 October 2008 5 3 5 Maintenance 5 1 2 Exchanging a power module Never touch the contacts on the backside of a power module There is the danger of being harmed by residual voltage Furthermore the operation of the power module might be impacted by impurities Use gloves to
28. n a multi unit rack assembly or closed assembly the ambient temperature inside the assembly may not succeed the maximum rated ambient temperature e When installed in a rack the installation should be such that the amount of air flow required for safe opera tion of the equipment is not compromised The mounting of the equipment should be such that no hazardous condition is achieved due to uneven mechanical loading Barco NGC 105 R59770204 Revision 01 October 2008 1 6 1 Introduction 1 4 5 Servicing Mechanical or electrical modifications others than described in this manual must not be made to the devices Barco is not liable for damages resulting from modified devices Only authorized personnel should carry out other maintenance work not explicitly mentioned in this users manual Never open the case of NGC 105 Measurements and tests with the opened device may be carried out only in the factory or by specially trained personnel due to the dangers of electric shock 1 4 6 Cleaning Unplug this product from the wall outlet before cleaning Do not use liquid cleaners or aerosol cleaners See sec tion 5 3 Cleaning for a cleaning instruction 1 4 7 Re packing Keep the original shipping carton and packing material they will come in handy if you ever have to ship your unit For maximum protection repack your set as it was originally packed at the factory Barco NGC 105 R59770204 Revision 01 October 2008
29. n the filter mesh before cleaning e Open the front flap by unscrewing the screws 5 on the top of the front please refer to Figure 3 1 e Use a vacuum cleaner to remove the dust from the filter mesh It is advisable to vacuum clean the flap from both sides outside and inside to receive good results e Close the front flap again Removing the front flap for cleaning The front flap can easily be demounted from the NGC 105 and taken to a place where it can be cleaned more easily Open the front flap by unscrewing the screws 5 on the top of the front please refer to Figure 3 1 The hinges of the front flap are established with an angular bolt at each side please see the figure below It is additionally hold by a chain 1 knurl screw 2 angular bolt 3 strap hinge Figure 5 5 Opened front flap with fixation elements Unscrew the knurl screw 1 to remove the chain from the front flap Take care the front flap is then no longer supported and it might be necessary to retain it e The bolts 2 are pressed outwards by springs To remove the flap press both bolts together and turn them upwards into the strap hinges 3 This releases the front flap from the hinge e Now you can carry the flap to a location where you want to clean it e Use a vacuum cleaner to remove the dust from the filter mesh It is advisable to vacuum clean the flap from both sides outside and inside to receive good results e Reinstall the
30. ntenance describes the maintenance of NGC 105 Technical Appendix gives tabular overviews about the technical details of NGC 105 Troubleshooting gives advice if NGC 105 does not operate properly Index lists the keywords of the manual Chapters pages figures and tables are numbered separately Chapters are indicated by a point syntax e g 4 2 3 pages by a dash syntax e g 2 1 as figures and tables are e g figure 5 4 Barco NGC 105 R59770204 Revision 01 October 2008 1 2 1 Introduction 1 3 Styles and symbols The typographic styles and the symbols used in this document have the following meaning Bold Labels menus and buttons are printed in the Bold font Condensed Links to both other chapters of this manual and to sites in the Internet are printed condensed In the on line version of this manual all hyperlinks appear teal Courier Names of files and parts from programs are printed in the Courier font Courier bold Inputs you are supposed to do from the keyboard are printed in Courier bold font Within a piece of programming code this arrow marks a line that must be made up in two lines though meant to be one line S If you do not heed instructions indicated by this symbol there is a risk of damage to the equipment If you do not heed instructions indicated by this symbol there is a risk of electric shock and danger to personal health If you do not heed instructions indicated by this
31. rature variations radiation levels mechanical stability and strength enclosure construction and protection against risk of fire Simulated single fault condition testing ensures the safety of the equipment to the user even when the equip ment s normal operation fails Electromagnetic interference Electromagnetic emission of NGC 105 complies with EN55022 EN61000 3 2 EN61000 3 3 and the limits for a class A digital device pursuant to Part 15 of the FCC Rules Electromagnetic immunity of NGC 105 complies with EN55024 This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 1 4 2 Precautions For your own protection observe the following safety precautions when operating and servicing your device e Before operating the units please read this manual thoroughly and retain it for future reference e Observe all warnings and instructions printed on the devices e Servicing not explicitly mentioned in this manual should never be carried out by unauthorized personnel Never open the case of the unit without first disconnecting the power supply cord e To prevent fire or electric shock hazard do not expose this unit to rain or moisture e This product should be operated from an AC power source e Check that the voltage and frequency of your power supply match those printed on the device label with the rated electric
32. scscsesescscccecscsesesesescsesscasassesesesesesesesesseecececeeeeseees 3 6 3 4 Power MOUSE E eat nae A eee a a 3 7 3 5 CONNEC NG sca AR A A T A EES 3 8 35V NEW K usina dali lis 3 8 3 5 2 Video and data CONMECHION cccceccsssssscscsesesesesesesesesescsccssscscscscscsesssessssssssscsssssesececscsesesesessnssaeasaaeaes 3 8 3 5 3 POWT SUDDIW si scien octet niin Ii a i E 3 9 A OPETItNG oriinornicsrncrirssoirrrirrreroerirroriiro siris si sektit E tssk SEEE CEECEE EE ES EEEE EEEE 4 1 AN SwWitehing omand Occitan 4 2 4 2 Alarms WItH SMG 1 0 decai sE 4 3 422A HOUSING TANS a Rane arta stated 4 3 4 2 2 Processing boards Of NGS XXX cccccscscscscscscscscsesesesesesesesesssssesecececscsesesesssssscesasssesesesesesesesssecececaceeseaes 4 3 42 3 PoOWer modules tio das dr Ir ba fitter eet SAT 4 3 ADA SMG O A pe 4 3 LE ya PORO AE AER cas E EA A data tata cue tach A A E O 5 1 5 1 Replacing power MOUIES 0 ccccscscscscscscsescsesesesesesesesesesescsssesssscsescsesssssssssacavasssssacesecacscessesesesecececeeaeass 5 2 Barco NGC 105 R59770204 Revision 01 October 2008 Vv 5 1 1 Determining a defective power module uc cccccscscsessscscscccscscsesesssssasscasaesesescecsescsesesesesasaeaecseaes 5 3 5 1 2 Exchanging a power MOUIE cceccscscscsesesesesesesesesesesecsescscscscscsesesesesssasasessssssesesesesessseeecesaaeaeseees 5 4 5 2 Replacing FANS ii A Mediation bndadan Hanna anda dion 5 5 5 2 1 Determining the defective fan module 0
33. shine green It only indicates if a defective component was found in the shelf O As soon as the defective power module is removed and the remaining power modules are Barco NGC 105 R59770204 Revision 01 October 2008 5 4 5 Maintenance 5 2 Replacing Fans The two fans are located at the right side on the rear of the NGC 105 The fans are not dimensioned for redundant operation Therefore if one fan fails it must be replaced immediately or the NGC 105 must be switched off With only one fan running critical temperatures are reached after 10 to 15 minutes 1 knurl screw 2 handle bar 3 LED only operable with SMC 101 off fan OK red fan too slow too fast or failed number of the fan module on the housing 5 air supply openings Figure 5 3 Fan module 5 2 1 Determining the defective fan module If an SMC 101 is used with the NGC 105 then in case of a fan failure the status LED 2 at the front of the NGC 105 and the LED of the failed fan shines red please refer to section 4 2 Alarms with SMC 101 If no SMC 101 is used the defective fan can be detected watching the fans spinning through the air supply open ings If a fan spins too slow or not at all it is defective Barco NGC 105 R59770204 Revision 01 October 2008 5 5 5 Maintenance 5 2 2 Exchanging the defective fan module Loosen the knurl screw 1 of the defective fan module Picture 1 below Remove the fan module by pulling
34. t net 1 N2 RJ45 connector stream net net 2 Figure 3 5 Location of general interfaces on the SMC 101 Barco NGC 105 R59770204 Revision 01 October 2008 3 6 3 The device and its components 3 4 Power module The power modules have two LEDs each The LEDs are located on the upper side The power modules are located behind the front flap 4 4 3 4 1 green LED AC power OK shines when power is connected 2 green LED DC power OK shines after NGC 105 is switched on Figure 3 6 Power module Barco NGC 105 R59770204 Revision 01 October 2008 3 7 3 The device and its components 3 5 Connecting The NGC 105 is set up and configured at your site by trained service personnel Also the power and data cables are connected The following section serves as a description if you need to make changes on the operable sys tem O Network and data cables can be plugged while the system is running 3 5 1 Network To be able to transfer the streamed video and control data to other NBMS devices and to receive control com mands all connection boards of the NGC 105 provide redundant network connectivity for connection to a 1Gbit network for stream and data transfer This network is referred as video network Video network The video network is used to interconnect NBMS devices for data exchange Visual data is encoded to JPEG2000 streams The plugs that are used for the connection to the stream network are lab
35. ting power AA pean eae 3 8 CODING E id 3 9 POWET SUDPDIY cooooocococococococonocnonononononononononan aran nn anos 3 9 GISCONNE Ct atand a 5 8 VideO ANd data c ooooococococococononananannononononononononononoso 3 8 POWER Odin 1 5 connection board AE TETERA TON 1 4 MO ido 3 5 power module data POSO a AAA 3 3 CONNEC earann a e aii 3 8 power modules defective Mio at ia 5 5 AA aoar e 5 4 defective power module ooconononininicocinononononononoso 5 4 PED Sims aaa a eie 3 7 GOCUMENtATION 0 ee eeceeeceseeeeeeeeeeseseseseeetecneneeeeeeeees 1 8 orientation oo ee eeeeeeeeeccnceeesceceececnceceaeseseeeeaeeees 3 7 exchanging POSITION a seein ceee cert NE 5 2 MA ee cc echoes sem 5 5 power supply fan CONNEC CHING E EE 3 9 A aan a aa 5 5 poWerWitthiiocona n aa 3 2 3 3 hot swap elements processing board Mi ia a ia tido 5 5 NO iia io dan 3 5 housing luis a Bio IS Be 3 4 NGG 105 unitaria diia 3 2 redundant network connection oooocoocicininnnicnc 3 8 LEDs redundant power connection eceeeeeeeeeeeeees 3 9 fan MOQU ES 0 ae eaaa ori 4 3 removing power Modules ccccescscccscsesesssseseeeeeeees 3 7 4 3 AA aineas 5 7 processing boards oococonocococonononononononanonanaran nono 4 3 shelf management module See SMC 101 MUSA A AEE aeeens 3 5 3 6 Slots for NGS b0ardS cece cece eens 3 2 3 3 3 4 MAINTENANCE nenese aeii 5 1 SMC AO ari E E 3 6 MANUAL tii 1 8 Std tS LED Saree ii eee ee he 3 5 3 6 network switch
36. zu Schadensersatz verpflichten Alle Rechte aus der Erteilung eines Patents oder der Eintragung eines Gebrauchsmusters verbleiben bei uns Copyright 2008 by Barco All rights reserved No part of this document may be copied reproduced or translated It shall not otherwise be recorded transmitted or stored in a retrieval system without the prior written consent of Barco Guarantee and Compensation Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee On receipt the purchaser must immediately inspect all delivered goods for damage incurred during transport as well as for material and manufacturing faults Barco must be informed immediately in writing of any complaints The period of guarantee begins on the date of transfer of risks in the case of special systems and software on the date of commissioning at the latest 30 days after the transfer of risks In the event of justified notice of complaint Barco can repair the fault or provide a replacement at its own discretion within an appropriate period If this measure proves to be impossible or unsuccessful the purchaser can demand a reduction in the purchase price or cancellation of the contract redhibition All other claims in particular those relating to compensation for direct or indirect damage and also damage attributed to the operation of software as well as to other services provided by Barco being a component of the syste