1. COMMAND Data length XOR SUM Byte Head 02 Fixed OxAA 0xBB Length 02 There are several effective bytes that including FF 00 XOR follows this column Node ID 02 Destination Node Address Number X S XX Xx Low byte first 00 00 Broadcast to each reader Function 02 It will be transmission ability of each different X S code command Low byte frist Data 00 DO Data length is not fixed according to its purpose X S XOR each byte from Node ID to Last Data byte with OxFF REPLY DATA FORMAT Data length XOR SUM Byte Head 02 Fixed OxAA 0xBB Length 02 There are several effective bytes that including FF 00 XOR follows this column Node ID 02 Destination Node Address Number X S XX xX Low byte first 00 00 Broadcast to each reader Function 02 It will be transmission ability of each different X S code command Low byte frist Status 1 Reply result if succeed is 0 other fail Data 00 DO Data length is not fixed according to its purpose X S XOR 01 XOR each byte from Node ID to Last Data byte S S J NOTE if from Length to XOR have a data is AA data 0x00 but length don t changed then should follow a While a command send and after 100ms no reply then consider this command failed Command List 1 Initialize port 0x0101 2 Set device node number 0x0102 Ignore 3
2. aa bb 05 00 00 00 02 02 00 Respond aa bb 0a 00 52 51 02 02 00 46 ff a6 b8 a4 46 ff a6 b8 is card serial number 11 Mifare Select 0x0203 Function Select card Format aa bb 09 00 00 00 03 02 xx xx xx xx XOR Ninth to twelfth is card serial number Sample Host to Reader aa bb 09 00 00 00 03 02 46 ff a6 b8 a6 Respond aa bb 07 00 52 51 03 02 00 08 Oa 12 Mifare Hlta 0x0204 Function Hlta card Host to reader aa bb 05 00 00 00 04 02 06 Respond aa bb 06 00 52 51 04 02 00 05 13 Mifare Authentication1 0x0206 Ignore Function authenticate Card Key Stroe in RC500 Format aa bb xx 00 00 00 06 02 Auth mode Block KeyEE CHK Auth mode Authenticate mode 0x60 Key A 0x61 Key B Block Authenticate block KeyEE Key store in RC500 EEPROM group from 0 to 31 total 32 Sample Host to Reader aa bb 08 00 00 00 06 02 60 04 01 61 Authenticate Block4 Key group 01 Respond aa bb 06 00 11 12 06 02 00 07 14 Mifare Authentication2 0x0207 Function authenticate Card Format aa bb xx 00 00 00 07 02 Auth_mode Block xx xx xx xx xx xx XOR Auth_mode Authenticate mode 0x60 KEY A 0x61 KEY B Block Authenticate block Sample Host to Reader aa bb Od 00 00 00 07 02 60 04 ff ff ff ff ff ff 61 Authenticate Block 4 Key A FF FF FF FF FF FF Respond aa bb 06 00 52 51 07 02 00 06 15 Mifare Read 0x0208 Function Read block Format aa bb 06 00 00 00 08 02 Block XOR Block which block want read
3. Read device node number 0x0103 Ignore 4 Read device Mode 0x0104 SO Set buzzer beep 0x0106 Ignore 6 Set Led color 0x0107 7 Set reader working status 0x0108 Ignore 8 Set antenna status 0x010c 9 Mifare Request 0x0201 100 Mifare anticollision 0x0202 10 Mifare Select 0x0203 120 Mifare Hita 0x0204 130 Mifare Authentication1 0x0206 Ignore 140 Mifare Authentication2 0x0207 15 Mifare Read 0x0208 16 Mifare Write 0x0209 17 Mifare Initval 0x020A 18 Mifare Read Balance 0x020B 19 Mifare Decrement 0x020C 20 Mifare Increment 0x020D 21 Mifare Restore 0x020E Ignore 220 Mifare Transfer 0x020F Ignore 23 Mifare UltraLight Anticoll 0x0212 24 Mifare UltraLight Write 0x0213 250 Write key store in RC500 EEPROM Ignore 26 Set Reader to Sleep Mode 270 Set Reader to Halt Mode 1 Initialize port 0x0101 Function set baud rate Format aa bb 06000001 01 Baud para xor Chk Baud parameter 20 30 40 sy ol 70 sp 0 4800 1 9600 2 14400 3 19200 4 28800 5 38400 Don t use this module 6 57600 7 115200 Don t use this module sample Host To Reader aa bb 06 00 00 00 01 01 03 03 Set Baud Rate as 19200 Respond aa bb 06 00 bf ff 01 01 00 40 Set device node number 0x0102 not use of this version Read device node number 0x0103 not use of this version Read device Mode 0x0104 function read device mode and version Host
4. Sample Host to Reader aa bb 06 00 00 00 08 02 04 Oe Respond aa bb 16 00 52 51 08 02 00 00 00 00 00 00 00 00 00 00 00 00 00 12 34 56 78 01 Tenth to sixteenth byte is Data 16 Mifare Write 0x0209 Function write block Format aa bb 16 00 00 00 09 02 Block DO D1 D2 D3 D4 D5 D6 D7 D8 D9 Da Db Dc Dd De Df XOR Sample write data to Block4 Host to Reader aa bb 16 00 00 00 09 02 04 00 00 00 00 00 00 00 00 00 00 00 00 12 34 78 56 07 Respond aa bb 06 00 52 51 09 02 00 08 17 Mifare Initval 0x020A Function initialize purse Format aa bb 0a 00 00 00 0a 02 Block VO V1 V2 V3 XOR 18 Mifare Read Balance 0x020B Function read balance Format aa bb 06 00 00 00 OB 02 Block XOR Return four byte balance 19 Mifare Decrement 0x020C Function decrease balance Format aa bb 0a 00 00 00 Oc 02 Block VO V1 V2 V3 XOR 20 Mifare Increment 0x020D Function increase balance Format aa bb 0a 00 00 00 OD 02 Block VO V1 V2 V3 XOR 21 Mifare Restore 0x020E Ignore Function Restore a mifare_one block data to buffer Format aa bb 06 00 00 00 OE 02 Block XOR 22 Mifare Transfer 0x020F Function Transfer buffer data to a block Format aa bb 06 00 00 00 OF 02 Block XOR 23 Mifare UltraLight Anticoll 0x0212 Function UltraLight anticollision respond ultralight ID Format aa bb 05 00 00 00 12 02 CHK Sample Host to Reader aa bb 05 00 00 00 12 02 10 Respond aa bb Od 00 52 51 12 02 00 04 Ifae 11 14 7a 00 d9
5. to Reader aa bb 05 00 00 00 04 01 05 Respond aa bb 12 00 52 51 04 01 00 43 52 35 30 30 4c 52 2d 31 32 30 33 11 C R5 0 0 LR 1 2 03 This module should be CRO28 xxxxx Set buzzer beep 0x0106 Ignore Function beep format aa bb 06 00 00 00 06 01 Delay XOR Delay 10ms beep time XOR is xor check Sample Host to Reader aa bb 06 00 00 00 06 01 64 63 Respond aa bb 06 00 52 51 06 01 00 04 Set Led color 0x0107 Host To Reader aa bb 06 00 00 00 07 01 03 05 set Red amp green LED on Respond aa bb 06 00 bf bf 07 01 00 06 Tenth data is LED parameter function as below 0 LED RED Off LED GREEN Off 1 LED RED On LED GREEN Off 2 LED GREEN Off LED RED On 3 LED GREEN On LED RED ON Set reader working status 0x0108 Ignore Set antenna status 0x010c Host To Reader aa bb 06 00 00 00 Oc 01 00 OD set antenna off Tenth data is Antenna status parameter 0 Close Filed 1 Open Filed 9 Mifare Request 0x0201 Function Request Type a Card Format aa bb 06 00 00 00 01 02 req_code XOR req_code Request mode req_code 0x52 request all Type A card In filed req_code 0x26 request idle card sample Host To Reader aa bb 06 00 00 00 01 02 52 51 Respond aa bb 08 00 52 51 01 02 00 04 00 04 TagType 0x4400 ultra light 0x0400 M fare _Qre S50 0x0200 Mf are Oe S70 0x4403 Mfare DESFi re 0x0800 Mfare Pro 0x0403 Mfare Prox 10 Mifare anticollision 0x0202 Function card anticollision Format
6. 04 If ae 11 14 7a 00 is card serial number 24 Mifare UltraLight Write 0x0213 Function write mifare Ultralight Format aa bb 0a 00 00 00 13 02 Page DO D1 D2 D3 XOR Page which page want write data DO D3 data XOR xor check Sample Host to Reader aa bb Oa 00 00 00 13 02 04 88 88 88 88 15 Respond aa bb 06 00 52 51 13 02 00 12 25 Write key store in RC500 EEPROM Ignore Format aa bb xx 00 00 00 1602 Auth mode group xx xx xx xx xx xx XOR Auth_mode 0x60 KEY A 0x61 KEY B ignore in this command Group 0 31 write RC500 Eeprom Address from 0x80 to Ox1FF total 32 group XX XX XX XX XX XX KEY should be writed to EEPROM Sample Host to Reader aa bb Od 00 00 00 16 02 60 01 ff ff ff ff ff ff 75 Write group01 Key FF FF FF FF FF FF Respond aa bb 06 00 11 12 16 02 00 17 26 Set Reader to Sleep Mode Format aa bb 06 00 00 00 11 01 Sleep Mode xor Sleep Mode 0x01 set RF chip sleep Aa bb 06 00 00 00 11 01 01 11 Sleep Mode 0x00 set RF chip work Aa bb 06 00 00 00 11 01 00 10 27 Set Reader to Halt Mode Format aa bb 05 00 00 00 12 01 13 After rececived this command reader should turn to Halt mode Need a Low Pull on INTO can wake up reader
7. CR028 Low Power Low cost Reader Module User Manual 1 Mifare Standard Support e Mifare s50 Ik memory e Mifare S70 4k memory e Mifare UltraLight e Mifare Pro x e Other ISO14443 A N Technical Specification e Power supply 2 5 3 6 V 30 50mA e Sleep Mode lt 10mA Halt lt 5uA e Interface TTL232 e Transmission speed Default 19200 bps e R W distance of up to 50mm e Storage temperature 40 C 125 C e Operating temperature 25 C 80 C 3 Communication setting The communication protocol is byte oriented Both sending and receiving bytes are in hexadecimal format The communication parameters are as follows Baud rate 19200 bps Data 8 bits Stop 1 bit Parity None Flow control None 4 Dimension SIZE 38 2 38 2 3 100 mm PIN PIN Nane descri pti on 1 N 2 VW 42 Sv 3 60 3 AD AD 4 RXD TIL Rx 5 TXD TIL Tx 6 IND Lowto V ke up Reader in Hilt 7 N 8 N 9 SC SPI_ SCL 10 MSO SPI_ SCL 11 MH SPI MA 12 SS SPI SS Charact er Paranet er Mn Type Mx Uits vol t age 20 5 316 V current 40 nA incl ude antenna Initialization tine 600 uS Qertating tenperature 25 0 85 C Storage tenperature 40 125 ke Transmission rate Default 192000 NO 80 1 Data format Binary HEX hexadecimal Data package Length Node ID Function Code Data XOR

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - yodobashi.com  User`s Guide A4910 – Lubri  Samsung 27 collu biznesa WQHD monitors maksimālai produktivitātei Lietotāja rokasgrāmata  here. - Sixnet    Télécharger le document  Jøtul I 150 FL - Kominki norweskie  Hedland Flow Alert Micro and Reed Flow Switches for  Adshield EBT- Fiche technique Teinture Transparente    