        1K/2K/3K Online UPS Uninterruptible Power Supply System User
         Contents
1.                              The UPS is equipped with intelligent slot perfect for either SNMP or AS400 card  When installing  either SNMP or AS400 card in the UPS  it will provide advanced communication and monitoring  options    PS  USB port and RS 232 port can   t work at the same time     Step 4  Network connection  Network  Fax  Phone surge port    IN OUT    Connect a single modem phone fax line into surge protected    IN    outlet on the back panel of the  UPS unit  Connect from    OUT    outlet to the equipment with another modem fax  phone line cable     Step 5  Disable and enable EPO function  Keep the pin 1 and pin 2 closed for UPS normal operation  To activate EPO function  cut the wire  between pin 1 and pin 2     It   s in closed status for UPS  normal operation        Step 6  Turn on the UPS   Press the ON Mute button on the front panel for two seconds to power on the UPS   Note  The battery charges fully during the first five hours of normal operation  Do not expect  full battery run capability during this initial charge period     Step 7  Install software   For optimal computer system protection  install UPS monitoring software to fully configure UPS  shutdown  You may insert provided CD into CD ROM to install the monitoring software  If not   please follow steps below to download and install monitoring software from the internet    1  Go to the website http     www power software download com   2  Click ViewPower software icon and then choose your required OS
2.    1K  2K  3K Online UPS    Uninterruptible Power Supply System    Table of Contents    1  Important Safety WarningG         sccssseesnseesnsenseeenenes    1 1  Transportation   1 2  Preparation   1 3  Installation   1 4  Operation   1 5  Maintenance  service and faults    2  Installation and SCCUP       ccesenceeneeesnseeeneeesneeeensenes    2 1  Rear panel view  2 2  Setup the UPS    J ODEaALION Seanina aiei    3 1  Button operation   3 2  LCD Panel   3 3  Audible Alarm   3 4  LCD display wordings index  3 5  UPS Setting   3 6  Operating Mode Description  3 7  Faults Reference Code   3 8  Warning indicator    4  TrOUDIESNOOTING        ceccesneesneesnseesneesneesneessensensnens  5  Storage and Maintenance        1csscesseeesseesssensnensnees    6  SPSCIMCALIONS siririna    U NN N N    1  I mportant Safety Warning    Please comply with all warnings and operating instructions in this manual strictly  Save this manual  properly and read carefully the following instructions before installing the unit  Do not operate this  unit before reading through all safety information and operating instructions carefully    1 1  Transportation    Please transport the UPS system only in the original package to protect against shock and  impact     1 2  Preparation    Condensation may occur if the UPS system is moved directly from cold to warm  environment  The UPS system must be absolutely dry before being installed  Please allow  at least two hours for the UPS system to acclimate the environ
3.   VER LOAD Indicates overload   SHORT Indicates the load or the UPS output is short circuit     Programmable outlets information   Indicates that programmable management outlets are working   ode operation information  Indicates the UPS connects to the mains        ii    Indicates the battery is working   Indicates the bypass circuit is working     Indicates the ECO mode is enabled        0    Indicates the Inverter circuit is working        Indicates the output is working     Battery information    Indicates the Battery level by 0 25   26 50   51 75   and    76 100      i                    BATT  FAULT Indicates the battery is fault   LOW BATT  Indicates low battery level and low battery voltage     Input  amp  Battery voltage information    HAA Uae Indicates the input voltage or frequency or battery voltage      Hz    mei A Vac  Input voltage  Vdc  battery voltage  Hz  input frequenc          3 3  Audible Alarm    3 4  LCD display wordings index    mma EAR       ENA  1S      3 5  UPS Setting       There are three parameters to set up the  Parameter 1 UPS     Parameter 1  It   s for program  alternatives  There are 8 programs to set  up  Refer to below table    Parameter 2 and parameter 3 are the  setting options or values for each  program        Parameter 2 Parameter 3    10       O1  Output voltage settinc                         Parameter 3  Output voltage   For 208 220 230 240 VAC models  you may choose the  following output voltage    208  presents output voltage is 20
4.   its ECO mode function allows cost effective operation           3  Installation and setup    NOTE  Before installation  please inspect the unit  Be sure that nothing inside the package is  damaged  Please keep the original package in a safe place for future use    NOTE  There are two different types of online UPS  standard and long run models  Please refer to  the following model table          IKL    Standard Long run     3KL      2 1  Rear panel view  1K L  TOWER                      Africa Type NEMA Type          2K L  TOWER          NEMA Type    India Type Africa Type    Schuko Type       NEMA Type    Africa Type             India Type       Schuko Type          UK Type    critical loads     1  Programmable outlets  connect to non    critical loads     2  Output receptacles  connect to mission     3  AC input    Input circuit breaker  5  Network Fax Modem surge protection    4     6  Emergency power off function connector  EPO     7  USB communication port   8  RS 232 communication port   9  SNMP intelligent slot   10  External battery connection  only available for L model   11  Output terminal   12  Output circuit breaker   13 Input terminal    2 2  Setup the UPS   Step 1  UPS input connection   Plug the UPS into a two pole  three wire  grounded receptacle only  Avoid using extension cords       For 208 220 230 240VAC models  The power cord is supplied in the UPS package       For 110 115 120 127VAC models  The power cord is attached to the UPS  The input plug is a  N
5.  icon AN  ng LOVER LOAD  UPS is overload Hp loads from    E ers i sid leche UPS is overloaded  Devices   Remove excess loads from  connected to the UPS are UPS output   fed directly by the electrical  network via the B  After repetitive overloads  Remove excess loads from  the UPS is locked in the UPS output first  Then shut  Bypass mode  Connected down the UPS and restart it   devices are fed directly by  the mains    Fault code is shown as 43 and The   The UPS shut down Remove excess loads from      NETES automatically because of UPS output and restart it   a euu n overload at the UPS output            display and alarm is continuously  sounding        Fault code is shown as 14 and the   The UPS shut down Check output wiring and if  icon is lighting on LCD automatically because short   connected devices are in  display and alarm is continuously   Circuit occurs on the UPS short circuit status   sounding  output     15    Fault code is shown as 1  2  3  4    A UPS internal fault has   Contact your dealer  11  12  13 and 41 on LCD display   occurred  There are two  and alarm is continuously possible results   sounding  1  The load is still Supplied   but directly from AC power  via bypass   2  The load is no longer  supplied by power   Battery backup time is shorter than   Batteries are not fully Charge the batteries for at  nominal value charged least 5 hours and then  check capacity  If the  problem still persists   consult your dealer     Batteries defect Contact your deal
6.  mode        12    3 6  Operating Mode Description    Operating mode LCD display    Online mode When the input voltage is within acceptable  range  UPS will provide pure and stable AC  power to output  The UPS will also charge  the battery at online mode    ECO mode Energy saving mode    When the input voltage is within voltage  regulation range  UPS will bypass voltage to  output for energy saving     Frequency  Converter mode                         When input frequency is within 40 Hz to 70  Hz  the UPS can be set at a constant output  frequency  50 Hz or 60 Hz  The UPS will  still charge battery under this mode     Battery mode When the input voltage is beyond the  acceptable range or power failure and  alarm is sounding every 4 second  UPS will  backup power from battery    Bypass mode When input voltage is within acceptable  range but UPS is overload  UPS will enter  bypass mode or bypass mode can be set by  front panel  Alarm is sounding every 10  second    Standby mode UPS is powered off and no output supply  power  but still can charge batteries     3 7  Faults Reference Code    Fault event Fault code Fault event Fault code   Ic                                  on  11   x    Overtemperature  41   x     Inverter soft start fail    1  2  3  4  11  Inverter voltage high       13    3 8  Warning indicator    T Sounding every second  Over Charge      Sounding every second    EPO enable AN Sounding every second    Sounding every second  Charger failure Sounding every secon
7.  to download the software   3  Follow the on screen instructions to install the software    4  When your computer restarts  the monitoring software will appear as an orange plug icon  located in the system tray  near the clock     Step 8  External battery connection  for long run models only   Follow the right chart to make external  battery connection        To external battery    3 1  Button operation    Turn on the UPS  Press and hold ON Mute button for at least 2 seconds  to turn on the UPS   Mute the alarm  When the UPS is on battery mode  press and hold this  button for at least 5 seconds to disable or enable the alarm system  But  its not applied to the situations when warnings or errors occur   Down key  Press this button to display previous selection in UPS setting  mode   Switch to UPS self test mode  Press ON Mute buttons simultaneously for  5 seconds to enter UPS self testing while in AC mode  ECO mode  or  converter mode   Turn off the UPS  Press and hold this button at least 2 seconds to turn  off the UPS in battery mode  UPS will be in standby mode under power  normal or transfer to Bypass mode if the Bypass enable setting by  pressing this button   Confirm selection key  Press this button to confirm selection in UPS  setting mode   Switch LCD message  Press this button to change the LCD message for  input voltage  input frequency  battery voltage  output voltage and  output frequency  It will return back to default display when pausing for  Select Button 10 se
8. 8Vac   220  presents output voltage is 220Vac   230  presents output voltage is 230Vac   240  presents output voltage is 240Vac   For 110 150 120 127 VAC models  you may choose the  following output voltage    110  presents output voltage is 110Vac   115  presents output voltage is 115Vac   120  presents output voltage is 120Vac   127  presents output voltage is 127Vac    Parameter 2  amp  3  Enable or disable converter mode  You  may choose the following two options    CF ENA  converter mode enable   CF DIS  converter mode disable    Parameter 2  amp  3  Output frequency setting     You may set the initial frequency on battery mode    BAT 50  presents output frequency is 50Hz   BAT 60  presents output frequency is 60Hz   If converter mode is enabled  you may choose the following  output frequency    CF 50  presents output frequency is 50Hz   CF 60  presents output frequency is 60Hz    Parameter 3  Enable or disable ECO function  You may  choose the following two options    ENA  ECO mode enable   DIS  ECO mode disable    Parameter 2  amp  3  Set the acceptable high voltage point and  low voltage point for ECO mode by pressing Down key or Up  key    HLS  High loss voltage in ECO mode in parameter 2    For 208 220 230 240 VAC models  the setting range in  parameter 3 is from  7V to  24V of the nominal voltage   For 110 115 120 127 VAC models  the setting range in  parameter 3 is from  3V to  12V of the nominal voltage        LLS  Low loss voltage in ECO mode in parameter 2   Fo
9. EMA 5 15P for 1K  1KL  1 5K and 1 5KL models  NEMA 5 20P for 2K and 2KL models    Note  for Low voltage models  Check if the site wiring fault indicator lights up in LCD panel  It will   be illuminated when the UPS is plugged into an improperly wired utility power outlet  Refer to   Troubleshooting section      Step 2  UPS output connection     For socket type outputs  there two kinds of outputs  programmable outlets and general  outlets  Please connect non critical devices to the programmable outlets and critical devices  to the general outlets  During power failure  you may extend the backup time to critical  devices by setting shorter backup time for non critical devices      For terminal type input or outputs  please follow below steps for the wiring configuration   a  Remove the small cover of the terminal block  b  Suggest using AWG14 or 2 1mm  power cords  Suggest using WG12 10 or  3 3mm  5 3mm  power cords for NEMA type   c  Upon completion of the wiring configuration  please check whether the wires are securely   affixed    d  Put the small cover back to the rear panel     Step 3  Communication connection  Communication port   USB port RS 232 port Intelligent slot          To allow for unattended UPS shutdown start up and status monitoring  connect the  communication cable one end to the USB RS 232 port and the other to the communication port of  your PC  With the monitoring software installed  you can schedule UPS shutdown start up and  monitor UPS status through PC
10. conds   Setting mode  Press and hold this button for 5 seconds to enter UPS  setting mode when UPS is in standby mode or bypass mode   Up key  Press this button to display next selection in UPS setting mode   Switch to bypass mode  When the main power is normal  press ON Mute  ON Mute   Select and Select buttons simultaneously for 5 seconds  Then UPS will enter to  Button bypass mode  This action will be ineffective when the input voltage is  out of acceptable range     ON Mute Button    OFF Enter Button       3 2  LCD Panel    BackupTimelnfo Fault Info       Input  amp  Battery Mute Operation    Voltage Info        Output  amp  Battery  ALES M Voltage Info    bweur       _ _oureur     Load into       Battery Info         j o    fed  Programmable  Mode Sowa Outlet Info    Info    Display  Backup time information    Indicates the backup time in pie chart   Hoc Indicates the backup time in numbers   S LILI H  hours  M  minute  S  second    Fault information       Indicates that the warning and fault occurs     E Indicates the warning and fault codes  and the codes are listed in  details in 3 5 section     i    M         te operation  x    Out        I  m    Indicates that the UPS alarm is disabled     ut  amp  Battery voltage information    O    mpa a ys Indicates the output voltage  frequency or battery voltage   lal LIS Hz Vac  output voltage  Vdc  battery voltage  Hz  frequency    ad information  Lf  Indicates the load level by 0 25   26 50   51 75   and 76 100              
11. d  Out of bypass voltage range Sounding every second    Sounding every second       14    4  Troubleshooting    If the UPS system does not operate       _  a please solve the a e by using the table below     Possiblecause       Remedy        No indication and alarm even The AC input power is not   Check if input power cord   though the mains is normal  connected well  firmly connected to the  mains    The AC input is connected   Plug AC input power cord to   to the UPS output  AC input correctly     EPO function is activated  Set the circuit in closed  position to disable EPO  function         The icon Aana the warning code  EP flashing on LCD display and  alarm is sounding every second   Line and neutral conductors   Rotate mains power socket      Crh  The icon Aand ve flashing on   of yps input are reversed    by 180   and then connect to  LCD display and alarm is sounding UPS system     every second    The icon Pana flashing on The external or internal Check if all batteries are  battery is incorrectly connected well    connected        LCD display and alarm is sounding  every second   Fault code is shown as 27 and the   Battery voltage is too high   Contact your dealer     oa or the charger is fault   icon is lighting on LCD 3    display and alarm is continuously  sounding   Fault code is shown as 28 and the   Battery voltage is too low or   Contact your dealer       oe the charger is fault   icon is lighting on LCD 3    display and alarm is continuously  sounding     The
12. e electrically live even if the UPS system is not  connected to the building wiring outlet    In order to fully disconnect the UPS system  first press the OFF Enter button to  disconnect the mains    Prevent no fluids or other foreign objects from inside of the UPS system     1 5  Maintenance  service and faults     The UPS system operates with hazardous voltages  Repairs may be carried out only by   qualified maintenance personnel      Caution   risk of electric shock  Even after the unit is disconnected from the mains   building wiring outlet   components inside the UPS system are still connected to the  battery and electrically live and dangerous    Before carrying out any kind of service and or maintenance  disconnect the batteries and   verify that no current is present and no hazardous voltage exists in the terminals of high   capability capacitor such as BUS capacitors      Only persons are adequately familiar with batteries and with the required precautionary  measures may replace batteries and supervise operations  Unauthorized persons must  be kept well away from the batteries       Caution   risk of electric shock  The battery circuit is not isolated from the input voltage   Hazardous voltages may occur between the battery terminals and the ground  Before  touching  please verify that no voltage is present      Batteries may cause electric shock and have a high short circuit current  Please take the  precautionary measures specified below and any other measures nec
13. er to  replace the battery     Check fans and notify  dealer      The icon Land the warning code      FFA flashing on LCD display and Fan is locked or not working  alarm is sounding every second        16    5  Storage and Maintenance    5 1  Operation    The UPS system contains no user serviceable parts  If the battery service life  3 5 years at  25  C ambient temperature  has been exceeded  the batteries must be replaced  In this case   please contact your dealer            Be sure to deliver the spent battery to a recycling facility or ship it to your dealer  in the replacement battery packing material        Storage    Before storing  charge the UPS 5 hours  Store the UPS covered and upright in a cool  dry  location  During storage  recharge the battery in accordance with the following table     Storage Temperature Recharge Frequency Charging Duration     25  C   40  C Every 3 months  40  C   45  C Every 2 months       17          6  Specifications       INPUT   170 VAC   150 VAC   130 VAC   110 VAC  5    Voltage   based on load percentage 100    80    80    70    70   60     60     0   Range    0 99   220 230 VAC  full load   OUTPUT       utput voltage 208 220 230 240VAC  C Voltage Regulation   3   Batt  Mode     eae ena ge 47   53 Hz or 57   63 Hz  Synchronized Range     Frequency Range  Batt  Mode          50 Hz   0 25 Hz or 60Hz   0 3 Hz    100   110   audible warning  110   130   UPS shuts down in 30 seconds at battery mode or transfers to bypass    mode when the uti
14. essary when  working with batteries       remove wristwatches  rings and other metal objects     use only tools with insulated grips and handles      When changing batteries  install the same number and same type of batteries      Do not attempt to dispose of batteries by burning them  This could cause battery  explosion      Do not open or destroy batteries  Escaping electrolyte can cause injury to the skin and  eyes  It may be toxic      Please replace the fuse only with the same type and amperage in order to avoid fire  hazards      Do not dismantle the UPS system     2  Introduction   Thank you for purchase the online UPS  This online UPS applies double conversion technology to  offer extremely tight voltage and frequency regulation for critical applications  With built in  isolation transformer  the UPS will offer full isolation and complete common mode noise rejection  for connected precious equipment  It becomes an ideal power source with 100  protection  against unexpected AC power problems  Besides  this series also provides programmable power  management outlets and multiple operation modes  emergency power off  EPO  function   eco mode operation  ECO  and converter modes     Equipped with programmable power management outlets  it can extend available battery time to  critical devices by shutting down unnecessary devices  It also accepts wide input voltage range  and offers configurable frequency converter mode for harsh applications such as generators  In  addition
15. lity is normal    gt 130   UPS shuts down immediately at battery mode or transfer to bypass mode  when the utilit    is normal     Overload                      urrent Crest Ratio 3 1  day    lt  3   THD  Linear Load   lt  4  THD  Linear Load   AMS Orn  lt  6   THD  Non linear Load   lt  7  THD  Non linear Load   Zero  Time 4 ms  Typical   Waveform  Batt  Mode   EFFI Cl ENCY    83   BATTERY  Numbers     3   A  extended      6   8 extended   6   8  extended     Standard 4 hours recover to 90  capacity  Typical   Model  1  1   1   1   1   1   reer  1  1   1   1   1   1     PHYSICAL    PHYSICAL  ae 465 X 210 X  525 X 210 X 465 X 210 X 525 X 210 X    Net Standard model 22 6 kgs 25 kgs 43 8 kgs 50 kgs 50 kgs 57 kgs  Weight  Long run model 17 1 kgs 17 5 kgs 34 3 kgs 36 kgs 34 3 kgs 36 kgs          ENVI RONMENT   20 90   RH   0  40  C  non condensing   MANAGEMENT   Power management from SNMP manager and web browser         Derate capacity to 60  of capacity in Frequency converter mode and to 80  when the output voltage is adjusted to 208VAC     18    
16. ment    Do not install the UPS system near water or in moist environments    Do not install the UPS system where it would be exposed to direct sunlight or near  heater    Do not block ventilation holes in the UPS housing     1 3  Installation    Do not connect appliances or devices which would overload the UPS system  e g  laser  printers  to the UPS output sockets    Place cables in such a way that no one can step on or trip over them    Do not connect domestic appliances such as hair dryers to UPS output sockets    The UPS can be operated by any individuals with no previous experience    Connect the UPS system only to an earthed shockproof outlet which must be easily  accessible and close to the UPS system    Please use only VDE tested  CE marked mains cable  e g  the mains cable of your  computer  to connect the UPS system to the building wiring outlet  shockproof outlet    Please use only VDE tested  CE marked power cables to connect the loads to the UPS  system    When installing the equipment  it should ensure that the sum of the leakage current of  the UPS and the connected devices does not exceed 3 5mA     1 4  Operation    Do not disconnect the mains cable on the UPS system or the building wiring outlet   shockproof socket outlet  during operations since this would cancel the protective  earthing of the UPS system and of all connected loads    The UPS system features its own  internal current source  batteries   The UPS output  sockets or output terminals block may b
17. r 208 220 230 240 VAC models  the setting range in    parameter 3 is from  7V to  24V of the nominal voltage   For 110 115 120 127 VAC models  the setting voltage in       parameter 3 is from  3V to  12V of the nominal voltage       06  Bypass enable  disable when UPS is off    Parameter 3  Enable or disable Bypass function  You may  choose the following two options    ENA  Bypass enable   DIS  Bypass disable    Parameter 2  amp  3  Set the acceptable high voltage point and  acceptable low voltage point for Bypass mode by pressing the  Down key or Up key    HLS  Bypass high voltage point   For 208 220 230 240 VAC models    230 264  setting the high voltage point in parameter 3 from  230Vac to 264Vac    For 110 115 120 127 VAC models    120 132  setting the high voltage point in parameter 3 from  120Vac to 132Vac   LLS  Bypass low voltage point   For 208 220 230 240 VAC models    170 220  setting the low voltage point in parameter 3 from  170Vac to 220Vac   For 110 115 120 127 VAC models    85 115  setting the low voltage point in parameter 3 from  85Vac to 115Vac          e 08  Programmable outlets enable  disable               OO  Exit setting          Parameter 3  Enable or disable programmable outlets   ENA  Programmable outlets enable  DIS  Programmable outlets disable    Parameter 3  Set up backup time limits for programmable  outlets    0 999  setting the backup time limits in minutes from 0 999  for programmable outlets which connect to non critical  devices on battery
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
One BIG Punch User Manual 06 MAR 2003  5.11 Technical Notes - Red Hat Customer Portal  User's Guide to JADAMILU - Personal Homepages  Samsung SGH-P520 Uživatelská přiručka  RLM-150 LCD Monitor Drawer User Manual  View / the Complete Manual    binvac accidentes de trabajo investigados  Oszilloskop HM 407  manuale istruzioni 1370818    Copyright © All rights reserved. 