1. www koreix com 3 2 JetCon 6350 System CPU 16 bits 100MHZ RISC Based SDRAM 32K bytes Flash ROM 512K bytes EEPROM 2K bytes Watchdog embedded watchdog to auto reset system when system failure LED PWR Power Input plugged and On Green RDY System startup ready Yellow STS System failure Red Network Interface Ethernet IEEE 802 3 10Base T IEEE 802 3u 100Base TX Connector 1 RJ45 Auto MDI MDI X Protection Built in 1 5 KV magnetic isolation protection LED LAN Activity Green On amp Blinking Network Speed 10M Green Off 100M Green ON Digital Input Input Channels 12 Channels Input Type source type Input Mode D I or event counting DC Input 30V max Threshold Voltage 3 8V Responding Time to Host PC Request lt 2ms Isolation Voltage 3 75KVrms Digital Output Output Channels 4 Channels Output Type FET output sink type Output Mode Level or pulse output with programmable pulse width korenix Working Range 5 30VDC Driving Capacity 200mA 23 C Responding Time to Host PC Request lt 2ms Output Initial State Programmable Isolation Voltage 3 75KVrms Protection over current 400mA channel trip 23 C Isolated Power supply Power supply 5V 200mA power on off with Configuration Isolation Voltage 3KVdc Features Network Protocols IP TCP UDP HTTP BOOTP DHCP Modbus TCP Configuration Network I O setting Watchdog Firmware update Windows Utility
2. JetCon 6300 Commander Logic Rules Conditions of the Dl Counter values Actions include DO Pulse and Counter Peer to peer Power Requirements System Power external unregulated 24V 10 30V Power Consumption Max 2W Mechanical Dimensions 120 H x 55 W x 99 D mm Mounting Din Rail Material Aluminum Environmental Regulatory Approvals EMI FCC Class B CE EN55022 2003 Class B CE EN61000 3 2 2000 Harmonic test KoreCARE korenix com JET amp eIxy Industrial Smart Ethernet I O Converter CE EN61000 3 3 1995 Flicker test EMS EN61000 4 2 2001 ESD test Level 3 Contact 6KV Air 8KV with criterion performance A EN61000 4 3 2002 RS test Level 3 10V m with criterion performance A EN61000 4 4 2004 EFT test Level 3 Power supply 2KV 5KHz UO 1KV 5KHz with criterion performance A EN61000 4 5 2001 Surge test Level 3 L N 2KV with criterion performance A EN61000 4 6 2003 CS test Level 3 with criterion performance A Vibration IEC60068 2 6 Shock IEC60068 2 27 Free Fall IEC60068 2 32 Operating Temperature 25 70 C Operating Humidity 20 90 non condensing Storage Temperature 40 85 C www koreix com korenix 4 Further Support Korenix Technologies Co Ltd 9F No 100 1 Ming Chuan Rd Shing Tien City Taipei Taiwan Tel 886 2 82193000 Fax 886 2 82193300 Business service sales korenix com Customer service koreCARE korenix com
3. L dE EE DO GND jo Internal Circuitry l Isolated Circuitry Picture 8 DO Circuit Structure www koreix com a korenix 2 6 5 DO Interface Wiring Digital Output ON State Readback as 1 OFF State Readback as 0 Sink Type Short to GND vt Tsolation 3KVdc Picture 9 DO Channel Wiring 2 6 6 DI DO Wiring and On Off Logic Table JetCon 6300 provides an internal isolated voltage called Viso for DI DO contacts Viso can be turn on off through management The relationship of Viso state DI DO wiring and the result of channel is summarized below iso ON iso OFF ON State OFF State OFF State DI DI Vt 3 5 30Vdc SW Open Vt 3 5 30Vdc SW Open and Or and Or SW Close Vt 3Vdc SW Close Vt 3Vdc Load Load with Vt Load POSEE NU without Vt 4Vdc without 200mA max current 200mA current Viso an isolated power supply Wet Contact Vt The power voltage from an external device KoreCARE korenix com JEtisel ft Industrial Smart Ethernet I O Converter Table 1 DI DO Wiring and On Off Logic Table 2 7 Wiring Fast Ethernet Port The fast Ethernet port of JetCon 6300 series supports either 10Base T or 100Base TX full or half duplex modes The port detects the signal from the peer device to negotiate the link speed and duplex mode automatically The port is also capable of Auto MDI MDIX which allows connect another switch hub or workstation by either a straight through
4. Voltage 3 75KVrms korenix Isolated Power supply Power supply 5V 200mA power on off with Configuration Isolation Voltage 3KVdc Features Network Protocols IP TCP UDP HTTP BOOTP DHCP Modbus TCP Configuration Windows Utility Web browser Firmware update Windows Utility JetCon 6300 Commander Logic Rules Conditions of the Dl Counter values Actions include DO Pulse Counter Peer to Peer Peer to Peer One to one multiple to one or one to multiple peers Power Requirements System Power external unregulated 24V 10 30V Power Consumption Max 2W Mechanical Dimensions 120 H x 55 W x 99 D mm Mounting Din Rail Material Aluminum Environmental Regulatory Approvals EMI FCC Class B CE EN55022 2003 Class B CE EN61000 3 2 2000 Harmonic test CE EN61000 3 3 1995 Flicker test EMS EN61000 4 2 2001 ESD test Level 3 Contact 6KV KoreCARE korenix com JETI Industrial Smart Ethernet I O Converter Air 8KV Free Fall IEC60068 2 32 EN61000 4 3 2002 RS test Level 3 10V m Operating Temperature 25 70 C EN61000 4 4 2004 EFT test Level 3 Power supply Operating Humidity 20 90 non condensing 2KV 5KHz I O 1KV 5KHz Storage Temperature 40 85 C EN61000 4 5 2001 Surge test Level 3 L N 2KV Warranty 3 years EN61000 4 6 2003 CS test Level 3 Vibration IEC60068 2 6 Ordering Information Shock IEC60068 2 27 JetCon 6330 16 CH DI Smart Ethernet I O Converter
5. or a crossover cable Plug one end of an Ethernet cable into the fast Ethernet port and connect the other end to the attached switch or host The link LED lights up if the cable is correctly connected Always make sure that the cable length is less than 100 meters 328 feet LED Indication of LAN Link Active Green On amp Blinking Link Speed Yellow off for 10Base T Yellow on for 100Base TX The wiring cable types are as below 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100 Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000 Base TX 4 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m www koreix com 3 Technology Data 3 1 JetCon 6330 System CPU 100MHZ RISC Based SDRAM 32K bytes Flash ROM 512K bytes EEPROM 2K bytes Watchdog embedded watchdog to auto reset system when system failure LED PWR Power Input plugged and On Green RDY System startup ready Yellow STS System fail Red Network Interface Ethernet IEEE 802 3 10Base T IEEE 802 3u 100Base TX Connector 1 RJ 45 Auto MDI MDI X Protection Built in 1 5 KV magnetic isolation protection LED LAN Activity Green On amp Blinking Network Speed 10M Yellow Off 100M Yellow ON Digital Input Input Channels 16 Channels Input Type source type Input Mode DI or event counting DC Input 30V max Threshold Voltage 3 8V Responding Time to Host PC Request lt 2ms Isolation
6. Industrial Smart Ethernet I O Converter a Insert the upper end of DIN Rail clip into the back of DIN Rail track from its upper side b Push the bottom of DIN Rail clip into the track c Check if DIN Rail clip is attached on the track It is recommended to reserve at least 5mm interval between two JetCon devices for heat dispersing To remove from the track reverse the steps above 2 4 Grounding There is an Earth Ground pin on the Power Input terminal block at the bottom of JetCon 6300 Series To prevent the system from being damaged by noise or electrical shock please make exact connection with JetCon devices with the Earth Ground 2 5 Wiring Power Input Follow the steps below for power input wiring 1 According the pin assignment insert the wires into the contacts on the terminal block connector 2 Tighten the wire clamp screws to prevent DC wires from being loosened 3 Connect to and turn on the power source The range of the suitable power source is from 12 to 24 AWG 4 When the unit is ready the PWR LED turns yellow the RDY LED turns green Note It is a good practice to turn off the power and unplug the IN terminal block before making wire connections Otherwise your screwdriver blade can inadvertently short the terminal connections to the grounded enclosure 2 6 Wiring I O Channels Follow the pin assignment to insert the I O wires into the front contacts of the terminal block Tighten the wire clamp screws
7. JETIS JetCon 6300 Series User Manual Hardware Installation First Edition July 2008 korenix www korenix com korenix Copyright Notice Copyright 2008 Korenix Technology Co Ltd All rights reserved Reproduction without permission is prohibited Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to assure its accuracy Korenix assumes no liabilities resulting from errors or omissions in this document or from the use of the information contained herein Korenix reserves the right to make changes in the product design without notice to its users Acknowledgments Korenix is a registered trademark of Korenix Technology Co Ltd All other trademarks or registered marks in the manual belong to their respective manufacturers KoreCARE korenix com JEtisel ft Industrial Smart Ethernet I O Converter Table of Contents 1 OVER VIEW 3 1 1 PACKAGE CHECKLIST elec eiee Seu SEN SEENEN SEENEN 3 1 2 ABOUT THIS MANUALE 3 2 HARDWARE INSTALLATION sivsssscssccsisssscccesucssess
8. KoreCARE korenix com
9. em LED DIO Channels amp W ssen ait RDY Ready Pin Assignment eeo PWR Power DI CHO CH15 STS System Failure 20 Pins Pitch 3 8mm X Cc Model Name amp Major Features Industrial Smart Ethernet UO Converter 16 CH Digital Input Din Rail Din 35 35mm 10 100 Base TX Tus Fast Ethernet J Active Green On amp Blink Speed 10M Yellow Off 100M Yellw On JETA Power Input DC 24V 10 30V Picture 1 JetCon 6330 Appearance System LED DIO Channels amp Sen Ta RDY Ready Pin Assignment T CE Cee KE PWR Power DI CHO CH11 STS System Failure DO CHO DH3 M 20 Pins Pitch 3 8mm Model Name amp Major Features Industrial Smart Ethernet UO Converter 12 CH DI 4 CH DO Din Rail Din 35 35mm 10 100 Base TX gg GC Fast Ethernet NA on Active Green On amp Blink Speed 10M Yellow Off 100M Yellw On e Power Input DC 24V 10 30V Picture 2 JetCon 6350 Appreance www koreix com 2 2 Dimensions 106 20 ge ggsggggggg FEEF 120 00 7 20 m amp E oOoooooooooQo oooo0oo0oo0oo0oo0o0 v v PWR L_ aad Ed Picture 3 JetCon 6300 Dimensions 2 3 Din Rail Mounting JetCon 6300 Series is shipped with a DIN Rail clip Use the DIN Rail clip to mount JetCon 6300 on a DIN Rail track Picture 4 Din Rail Mounting step a and b KoreCARE korenix com JET amp eIxy
10. onnectivity In addition to remote data acquisition and channel control JetCon 6300 is programmable with smart I O rules An event of logic rule can be defined to modify the status of digital output channel either on the same device or to multiple JetCon 6300 series devices With the user defined logic rules multiple JetCon 6300 devices can execute the programmed control logic without further step in by user or other controls JetCon 6300 is constructed by aluminum case with IP31 protection for industrial environment and the Din Rail mounting is easy to install in control box with limited spaces The configuration is user friendly and the management interfaces include JetCon 6300 Commander Web as well as Modbus TCP protocol 1 1 Package Checklist JetCon 6300 is shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance e JetCon 6300 unit with attached mounting clip e Terminal blocks for power connecter and I O channels e Documentation and Software CD ROM e Quick Installation Guide 1 2 About This Manual This manual provides detailed information for both hardware installation and software configuration The software configuration is composed of JetCon 6300 Series Utility Web configuration and Modbus TCP configuration KoreCARE korenix com JETLS Industrial Smart Ethernet 1 0 Converter 2 Hardware Installation 2 1 Appearance Syst
11. sccsscssccesessesvsessaccvssdosccsesscescdeecasseanccesseceteossesss 4 2 1 IX PPE Pe 4 2 2 Ru OK e 5 2 3 DIN RAIL MOUNTING 6e chtoceet esecetv cuta eub eteveeeves EA eh eve Rue eU cU Y Eee Pee Y 5 2 4 GROUNDING ME Ee E Ee ee EE EENEG 6 2 5 WIRING POWER Iw 6 2 6 WIRING I O CHANNELS quu 6 2 0 1 SDE Circuitry Str ctire i eai RU HERE EE 7 2 6 2 DI Interface Dry Contact Wiring eese eene rennen rennen amp 2 6 3 DI Interface Wet Contact Wiring e eseeeeeeeseeeeeeeeee teen eterne entente nennen 9 2 0 4 DO Circuitry E 10 2 605 DO Interface Wiring eet ee tede est ce tutti se eio oo fede ren oce deMERRe 11 2 6 6 DI DO Wiring and On Off Logic Table essere eene Il PATA WIRING FAST ETHERNET Pop 12 3 TECHNOLOGY E H VM 13 3 1 ENEE 13 3 2 JerCoNoiat aa a a a a a EE E e a E EREA E 15 4 FURTHER SUPPORT win ciscsscccissssccosessessssectassssssocesoesceseocessesssceesessstesseessievssvonsessussessessdesssvseseosess 17 www koreix com korenix 1 Overview The Korenix JetCon 6300 series is a smart Ethernet I O converter with multiple digital input and output channels JetCon 6300 converts the signal of each I O channel into Ethernet messages The input channels support either digital input mode or event counter mode while the output channels provide digital output mode or pulse output mode User can monitor the real time status or control all the channels remotely through the built in Ethernet c
12. to prevent the I O wires from being loosened www koreix com 2 6 1 DI Circuitry Structure Controller DI Circuitry Structure korenix DI COM _ DI PwR C DLO bio DET CID Internal Circuitry Power SV Isolation 3KVdc V i Isolated Circuitry XP DI GND Picture 5 DI Circuit Structure DI GND KoreCARE korenix com JET Industrial Smart Ethernet I O Converter 2 6 2 DI Interface Dry Contact Wiring Digital Input OFF State Readback as 0 Dry Contact SW Open Power 5V Tsolation 3KVdc Digital Input ON State Readback as 1 Dry Contact SW Close to GND Power 5V Tsolation 3KVdc Picture 6 DI Dry Contact Wiring EN www koreix com 9 korenix 2 6 3 DI Interface Wet Contact Wiring Digital Input OFF State Readback as 0 Wet Contact SW Open or Vt lt 3 Vdc Power 5V Isolation 3KVdc Digital Input ON State Readback as 1 Wet Contact SW Close and Vt 3 5 30Vdc Power 5V Isolation 3KVdc Picture7 DI Wet Contact Wiring KoreCARE korenix com EN JETI Industrial Smart Ethernet I O Converter 2 6 4 DO Circuitry Structure DO Circuitry Structure 1 DO PWR Controller DO 0 AEN Viso Power OV Isolation 3KVdc