1. 238400 rw root dev ram initrd 0x80800000 5m ramdisk_size 12288 rootfstype ext2 CONFIG MTD PARTS b Analyze the configuration files of compilation kernel make adstrubog5 defconfig analysis cat Makefile grep rn defconfig actual executable configuration files are arch arm configs adsbitsyg5 defconfig c mx31 small system programming download u boot tftp 0x84000000 u boot bin to memory protect off 0xa0000000 0xa003ffff erase 0xa0000000 0x40000 cp b 0x84000000 0xa0000000 0x40000 Download tftp 0x84000000 zl mage to memory 32 Vantron VT HM1 5101 erase 0xa0080000 0x200000 cp b 0x84000000 0xa0080000 0x200000 Download ramdisk tftp 0x84000000 ramdisk gz erase 0xa0280000 0x500000 cp b 0x84000000 0xa0280000 0x500000 Download jffs2 tftp 0x84000000 flashfs1 tftp 0x84000000 rootfs jffs2 erase 0xa0780000 0x1880000 cp b 0x84000000 0xa0780000 0x1880000 bootm 0xa0080000 boot from the kernel Original parameter configuration bootargs console ttyS0 38400 SERIALGETTY ttySO SERIALBAUD 38400 rw root dev ram initrd 0x80800000 5m ramdisk_size 12288 rootfstyp e ext2 mtdparts flash0 256k boot 256k bootvars 2m zlmage 5 m ramdisk gz flashfs1 wherein initrd designates the storage address of ramdisk in memory uboot loads ramdisk images to memory the ramdisk images are not compressed but loaded to root file system by the kernel Modify root dev mtdblock4 rootfstyp e jffs2 noinitrd se
2. 6 2 Ethernet Interface oe eeeeeeeeeeeseeeeeeeeeeteteeeeeeeeeneeees 18 3 6 3 DSub 9 RS232 Connector sse 19 3 6 4 USB Host Connector sse 20 3 6 5 CAN CONNECTON eicere ettet rnit tatnen in 20 3 7 1 0 Interface Instructions eeeeeenenntrnnnnntnnnnnne 21 3 7 1 RS485 42 A t ete dies 21 3 8 PACK AG List ia sees terree ever ei 23 Software InstructiOn S nan enenenenenenenenenenenenenenenenenenenenenenenennensenenennn 24 41 Brief IntroductiOn nnnnenansennenrenneneeeervenenseeneneeeennenenenenenene 24 4 1 1 Serial Port Instructions eene 24 4 2 WinCE Instructions ertt trt taha s anda ee 25 4 2 1 Windows CE Application Development 25 4 2 2 Windows CE Firmware Update 25 4 2 3 Instructions for Windows CE Configuration Files 27 4 2 4 Notice of Touch Screen in WinCE 29 43 Linux instruct Ons iere ter ro rrr ee e Pero eua e 31 4 3 1 Linux Application Development neen 31 4 3 2 Linux Image Programming esee 32 4 3 3 Instructions for Linux Configuration Files 34 A34 SIart Cause rte nitrate eis 34 4 3 5 tty config txt 4 3 6 hw config txt 4 3 7 root c nfig Atsine iniiis iiien aa 35 4 3 8 Notice of Touch Screen in Linux sesser 36 Vantron VT HMI 5101 1 Foreword 1 1 Copyright Notice While all information contained herein have been carefully checked to assure its accuracy
3. ODL Mounting Window Size 294x201mm 15 Vantron VT HM1 5101 3 5 Hardware Installation The product supports standard VESA mounting 75 x 75mm x 3mm as well as side mounting The left and right sides of the device housing have two mounting slots respectively for inserting mounting brackets to needed positions by tightening screws as shown below Waterproof Cushion Mounting N a Mounting Locatin and Screw y 2 16 Vantron VT HMI 5101 3 6 Interface Description 3 6 1 DC24V Power Input 3 pins 5 08mm pitch terminal with screw lock 17 Vantron VT HMI 5101 3 6 2 Ethernet Interface Standard RJ45 interface supporting 10 M 100M self adaptation TX TX 18 Vantron VT HMI 5101 3 6 3 D Sub 9 RS232 Connector Standard vertical DB 9 male connector baud rate up to 921 600bps f a O 0 T GC J DCD RXD TXD DTR DSR RTS 19 Vantron VT HMI 5101 3 6 4 USB Host Connector Standard USB host connector type A TO Po USB NEG 3 6 5 CAN Connector 2 Pins 3 81mm pitch terminal CANBus 1 VH ales di 20 Vantron VT HM1 5101 3 7 I O Interface Instructions 3 7 1 RS485 422 3 7 1 1 485 Cable Connection VT HI 485 Device 3 7 1 2 422 Cable Connection VT HMI 422 Device 3 7 1 3 RS422 485 RS422 and RS485 share the same RJ11 interface
4. VT HMI 5101 User s Manual VAS Sy Pc Iso ARM E em AD 9000 Vantron Technology www vantrontech com All Rights Reserved Vantron VT HMI 5101 Revision History versen ben be No E M E NN m NI me Vantron Table of Contents A Me 1 13 Copyright Notie coepere terreri nero rete ea k in etaient 1 AM LI 2 1 3 Statements etn tertie rere iron in eae ek 2 14 Disclaimer i e Petre dai 3 1 5 Limitation of Liability Non warranty nennen ennenenenennn 3 1 6 Safety Instructions cocinan neris ertet eria e ces cae ivi 3 A severserdetegnnseederdenvieenverdaerdenveednd 4 1 8 Safety Instructions for Power Cables and Accessories 5 Overview P 7 2 3 Introducir ce ear andas 7 2 2 Product Seri ES nani eot oem iii 8 2 2 1 Product Order Coding Rule sss 8 2 2 2 Ordering Information 9 VT HMI 5101 Hardware Instructions 3 1 Product APpearance ccscsssssesssssessssessscsessssscssesessessasessesseesasees 10 3 2 Specifications naaa nne rneneenenveneenenvenenvenvenensenvenennenvenenvene 11 3 3 Interface Instructions nanne nen enenenenenenenenenenenenenenvenen 13 3 3 1 Bottom VIEW csi inci 33 2 Left View 34 Dimension 3 5 Hardware Installation 3 6 Interface Description 3 6 1 DC24V Power Input 5 Vantron 3
5. and the electrical 21 Vantron VT HM1 5101 properties thereof are determined according to different connection modes O RS 422 wiring suggestion VT HMI3081 3101 422 Device RX422 EIA485 RX422 EIA485 TX422 TX422 RS485 wiring suggestion VT HMI 3081 3101 485 Device RX422 EIA485 RX422 EIA485 TX422 TX422 22 Vantron VT HMI 5101 3 8 Packing List No PartDesciption Quantity we Install Mechanical tools 140040 0017EV VANTRON Cushion for Enclosure s Front 1pc 2 140010 0036EV VANTRON Panel Protection N Power Terminal 1pc 210071 01041EV 3pins ANYTEK VM 3 81 3P 23 Vantron VT HMI 5101 4 Software Instructions 4 1 Brief Introduction VT HMI 3081 has been pre loaded with WinCE5 0 or embedded Linux image so that the system can automatically run WinCE 5 0 or embedded Linux when powered up 4 1 1 Serial Port Instructions e j VT HMI 5101 As a default debug serial port COM1 cannot be used by application software normally But it can be used after the debug serial port is set to O or other ports by setting DebugPort parameters in ADSLOAD HWT see 4 2 3 1 e RS485 422 is COM3 24 Vantron VT HMI 5101 4 2 4 2 1 4 2 1 1 WinCE Instructions Windows CE Application Development Development Environment To create Win32 and MFC applications with EVC4 0 and create Win32 MFC and C applications with VS2003 VS2005 and VS2008 the integrated de
6. better double tap touch control effect by setting double tap sensitivity and physical distance parameter between two taps Set according to Double Tap selection in Stylus Properties The physical distance between two taps is recommended to be as great as possible for better finger touch effect Run Regflushkeys exe command after the setting so as to save the updated registry settings 30 Vantron VT HMI 5101 43 Linux Instructions 4 3 1 Linux Application Development 4 3 1 1 Linux Application Environment The operation environment of VT HMI application system is a QT Embedded open system with the following structure Qt Embedded Applications QWS Server Graphic Event Service Qt Embedded Frame Buffer Input Device Driver Linux Operating System Low level Hardware Platform Users can develop or transplant Qt Embedded based applications to HMI platform 4 3 1 2 Linux Application Operation O Manual operation Copy applications to relevant directory and operate by double clicking O Automatic operation Copy applications to directory etc rcS d and the system will automatically operate during the next system startup 31 Vantron VT HMI 5101 4 3 2 Linux Image Programming a Analyze u boot and MTD partition to determine programming partition u boot config include configs adstrubog5 h MTD driver drivers mtd maps ads flash c Hd efine CONFIG_BOOTARGS console ttyS0 38400 SERI ALGETTY ttySO SERIALBAUD
7. cessories N Proper power source only Start only with power source that satisfies voltage label and the voltage necessary according to this manual Please contact technical support personnel of Vantron for any uncertainty about the requirements of necessary power source N Use tested power source This product still contains a button lithium battery as a real time clock after its external power source is removed and therefore should not be short circuited during transportation or placed under high temperature N Place cables properly Do not place cables at any place with extrusion danger o gt gt gt lt gt Vantron VT HM1 5101 Naa ning Instructions Please power off before cleaning the device Do notuse spray detergent Clean with a damp cloth Do not try cleaning exposed electronic components unless with a dust collector Support for special fault Power off and contact technical support personnel of Vantron in case ofthe following faults gt Thedeviceis damaged gt Thetemperatureis excessively high gt Fault is still not solved after the operation according to the manual Vantron VT HMI 5101 2 Overview 2 1 Introduction Thank you for choosing Vantron It is our commitment to provide our valued customers with the embedded devices equipped with the state of the art technology and the best product services HMI the abbreviation for Human Machine Interface enables the interaction betwe
8. claimer Vantron assumes no legal liability of accidents resulting from failure of confor ming to the safety instructions 1 5 Limitation of Liability Non warranty For direct or indirect damage to this device or other devices of Vantron caused by failure of conforming to this manual or the safety instructions on device label Vantron assumes neither warranty nor legal liability even if the device is still under warranty 1 6 Safety Instructions Keep and comply with all operation instructions warnings and information lt gt Pay attention to warnings on this device lt gt Read the following precautions so as to decrease the danger of injury electric shock fire or any da mage to the device 1 7 Vantron VT HMI 5101 Precautions Pay attention to the product labels safety instructions printed on silk screens Do not try repairing this product unless declared in this manual Keep away from heat source such as heater heat dissipater or engine casing Do not insert other items into the slot if any of this device Keep the ventilation slot ventilated for cooling System fault may arise if other items are inserted into this device Installation ensure correct installation according to instructions from the manufacturer with recommended installation tools Ensure ventilation and smoothness according to relevant ventilation standard Vantron VT HMI 5101 1 8 Safety Instructions for Power Cables and Ac
9. e before using the touch screen The calibration comprises steps of selecting Start Settings Control Panel to step into the control panel interface tapping Stylus icon to step into Stylus Properties interface and tapping calibration to start calibrating You may use an auxiliary USB mouse for stepping into Stylus Properties interface After the calibration run Regflushkeys exe command immediately and save calibration parameters You can either input command Regflushkeys exe in Start Run or find the program in NWindows directory run it to update registry 29 Vantron VT HMI 5101 Stylus Properties ki OK x Double tap this grid to set the double tap sensitivity for both Lx the speed and physical distance between taps Double tap this icon to test your double tap settings If this icon doesn t change adjust your settings using the grid above Stylus Properties Picture 4 2 4 2 Setting Touch screen sensitivity and speed sensitivity The identification precision differences between finger touch and pen touch may results in different touch screen identification effects Pen touch has better identification effect while finger touch especially finger pulp touch gets relatively poorer precision Therefore it is recommended to operate with fingertips or pen especially at four corners and four sides so as to get optimal touch control effect Meanwhile you can get
10. en operators users and applications connects industrial control products such as PLC transducer DC speed regulator meter etc HMI adopts a display for displaying and input units such as touch screen keyboard mouse etc for writing working parameters or inputting operation commands As a digital device for realizing information interaction between human and machine HMI is composed of hardware and software Based on its ample function interfaces and powerful user operational interface it is very suitable for control units such as medical device intelligent transportation industrial field etc Vantron s VT HMI products are based on the most advanced ARM and Intel Atom processors and have low power consumption and high integration The products are designed for applications such as industrials medicals and transportations etc Vantron VT HMI 5101 2 2 Product Series 2 2 1 Product Order Coding Rule VT HMI A BB C Type suffix 1 Basic type 2 Enhanced type or other types Screen size 07 08 10 15 for LCD in 7 8 10 15 inches Product series 3 PXA270 ARM10 processor platform 5 IMX31 ARM11 processor platform 6 Intel ATOM x86 processor platform Vantron VT HMI 5101 2 2 2 Ordering Information Series 3 PXA 270 ARM10 processor based 8 4 TFT PXA270 520MHz Ethernet RS232 SERIA Dar RS422 485 USBH USBD 8 4 TET PXA270 520MHz Ethernet 5xRS232 VISHIMESOB 2xRS422 RS485 4xUSBH CAN TM 0 Hz E
11. in technical details and printing Vantron assumes no responsibility resulting from any error or features of this manual or from improper uses of this manual or the software Please contact our technical department for relevant operation solutions if thereis any problem that cannot be solved according to this manual Vantron reserves all rights of this manual including the right to change the content form product features and specifications contained herein at any time without prior notice The latest version of this manual is at www vantrontech com cn Please contact Vantron for further information Vantron Technology Vantron E mail sales vantrontech com Vantron VT HMI 5101 The trademarks and registered trademarks in this manual are properties of their respective owners No part of this manual may be copied reproduced translated or sold No changes or other purposes are permitted without the prior written consent of Vantron Vantron reserves the right of all publicly released copies of this manual 1 2 Notes Applicable notes are listed in the following table Important information and regulations Caution for latent da mage to system or harm Caution to personnel 1 3 Statement It is recommended to read and comply with this manual before operating VT HMI which provides important guidance and helps decreasing the danger of injury electric shock fire or any damage to the device Vantron VT HMI 5101 1 4 Dis
12. listed below 4 2 3 1 Adsload HWT Hardware configuration files can be opened by text editor and you therefore only need the following items and keep other items as hardware compatible settings the keywords and values of which should be separated by one or more spaces TAGS MouseDetect 0x01 DebugPort 0x01 BootLogo 0x02 LogoBckGround 0x3B74 27 Vantron VT HMI 5101 lt gt MouseDetect 1 the mouse arrow can be seen after OS is started 0 other values are invalid without mouse arrow DebugPort designate serial port for debugging default serial port 1 0 without debug serial port lt Bootlogo 0 Bootloader dose not display Logo 1 display Logo consolidated in system 2 display Adsload bmp 24bits or 16bits of bitmap files only lt LogoBckGround designate background color RGB565 format of Logo displayed in Bootloader 4 2 3 2 Adsload REG User s registry files can be opened by text editor and are standardized for example HKEY_LOCAL_MACHINE SOFTWARE CERDISP HostName 192 168 8 88 RefreshTi me dword 32 AllowRemote dword 0 The system automatically loads when started and you can add system registry information therein according to your own needs i Notice The last row of this file must be followed by an Enter 28 Vantron VT HM1 5101 4 2 4 Notice of Touch Screen in WinCE 4 2 4 1 Touch Screen Calibration i To get better touch precision you need to calibrat
13. livered to specialized electrical amp electronic waste recycling disposal center Proper disposal of this sort of waste helps avoiding harm and adverse effect upon surroundings and people s health Please contact local organizations or recycling disposal center for more recycling disposal methods of related products Comply with the following safety tips AN Do not use in combustible and explosi ve environment Keep away from combustible and explosive environment for fear of danger 37 Vantron VT HMI 5101 AM Keep away from all energized circuits Operators should not remove enclosure from the device Only the group or person with factory certification is permitted to open the enclosure to adjust and replace the structure and components of the device Do not change components unless the power cord is removed In some cases the device may still have residual voltage even if the power cord is removed Therefore it is a must to remove and fully discharge the device before contact so as to avoidinjury N Unauthorized changes to this product or its components are prohibited In the aim of avoiding accidents as far as possible itis not allowed to replace the system or change components unless with permission and certification Please contact the technical department of Vantron or local branches for help A Pay attention to caution signs Caution signs in this manual remind of possible danger Please comply with relevant safe
14. shfs1 is for designating items that need updating U boot image boot Linux knernal image zlmage Linux Ramdisk file system image ramdisk gz Linux jffs2 file system image jffs2 i Files designated by image_to_flash variables must exist in the SD card or USB 35 Vantron VT HMI 5101 4 3 8 Notice of Touch Screen in Linux 4 3 8 1 Touch Screen Calibration gt To get better touch control precision it is needed to calibrate before using the touch screen generally get electrified on equipment for the first time The program prompts for automatic calibration if the touch screen is not calibrated The system automatically saves calibration parameter after the calibration Two methods for stepping into the calibration interface are listed below if further calibration is needed a select Start Recalibration command from the menu to step into calibration interface a b tap Stylus icon in setting bar to step into calibration interface 36 Vantron VT HMI 5101 5 Tips AN Waste Disposal It is recommended to disassemble the device before abandoning it in conformity with local regulations Please ensure that the abandoned batteries are disposed according to local regulations on waste disposal Do not throw batteries into fire explosive or put in common waste canister Products or product packages with the sign of explosive should not be disposed like household waste but de
15. t bootargs console ttyS0 38400 SERIALGETTY ttySO SERIALBAUD 38400 rw root dev mtdblock4 rootfstyp e jffs2 noinitrd mtdparts flash0 256k boot 256k bootvars 2m zlmage 5 m ramdisk gz flashfs 1 set zi mage cp b 0xa0080000 0x84000000 0x200000 convey to 33 Vantron VT HMI 5101 memory from flash set start bootm 0x84000000 set bootcmd run zlmage run start 4 3 3 Instructions for Linux Config uration Files N Modification and updating of software configurations are dangerous and may cause system boot failure Do not modify on your own unless with a good knowledge of each updating files 4 3 4 start txt The system automatically updates and starts scrip without user s modification 4 3 5 tty config txt Configure debug serial port and baud rate for the device lt Sfconsole The debug serial port adopted by the device could be set with values such as ttySO ttyS1 ttyS2 etc lt S baudrate The baudrate adopted by the debug serial port could be9 600 38 400 115 200 etc 34 Vantron VT HMI 5101 4 3 6 hw_config txt Configure parameters for LCD driven by the device It functions differently according to different types of device N Hardware compatibility settings must be kept without random modification 4 3 7 root config txt Configure items for automatic updating and boot parameters that will be adopted during the boot of updated system for example images to flash boot zlmage ramdisk gz fla
16. thernet RS232 SS ON SE Series 5 iMX31 ARM11 processor based EN men e ME Series 6 x86 processor based AA AE 15 1 TFT ATOM 1 1GHz 512MB 1000M iii Ethernet RS232 RS422 485 4xUSBH2 0 VEHMiI 6151 2 151 TFT ATOM 1 6GHz 512MB 1000M Ethernet RS232 RS422 485 4xUSBH2 0 Vantron VT HM1 5101 3 VT HMI 5101 Hardware Instructions 3 1 Product Appearance Front amp Side View Top View Back 8 Side View 10 Vantron VT HMI 5101 32 Specifications 10 2 16 9 LVDS LCD 1024 x 600 Display Touch Screen 4 Wires resistance type Hardness 4H 1xSpeak Out 3 5 mm Software mi 11 Vantron Environment Condition VT HM1 5101 optional for other colors Temperature Operating 10 C 60 C ETR 30 C 70 C Optional Storage 20 C 70 C ETR 40 C 80 C Optional Humidity 10 85 RH Non Condensation operating and storage Vibration 2G 9 26Hz 10 times in X Y Z directions Front Panel IP54 IP65 12 Vantron VT HM1 5101 3 3 Interface Instructions 3 3 1 Bottom View D Sub 9 RS232 Serial Port RS 485 422 Serial Port 13 Vantron VT HM1 5101 3 3 2 Left View CAN Wirin gOut Hole Mounting Locating Holes 14 Vantron VT HM1 5101 3 4 Dimension pari Eds LIA 292 222 315 DOQUDUROOOUDOUE EURO ORRRGU
17. ty tips below each sign Meanwhile you should strictly conform to all safety tips for operation environment 38 Vantron VT HMI 5101 j Notice Considering that reasonable efforts have been made to assure accuracy of this manual Vantron assumes no responsibility of possible missing contents and information errors in contents citations examples and source programs Vantron reserves the right to make necessary changes to this manual without prior notice No part of this manual may be reprinted or publicly releasedin forms of photocopy tape broadcast e document etc 39 Vantron VT HMI 5101 Vantron Chengdu Vantron Technology Ltd www vantrontech com cn Phone 86 28 85123930 85123931 85157572 85156320 Fax 86 28 85123935 E mail sales vantrontech com cn 40
18. velopment environment IDE can be purchased from the agents of Microsoft Company 4 2 2 1 2 3 4 5 6 Windows CE Firmware Update Copy Bootloader adsload rom configuration files adsload hwt adsload Reg OS image nk bin and background pictures adsload bmp to the root directory of SD card Insert the SD card to relevant slot Power on so that the system can automatically read and update relevant files from the SD card The updating process can be observed via the debug serial port The system continues operating after the updating Power off Take out the SD card and delete files stored therein Power on so that the updated items can automatically load and Operate 25 Vantron N Cautions 1 It is our strong suggestion to update firmware carefully because VT HM1 5101 this product recognizes firmware only according to firmware name Therefore it is a must to ensure that firmware in the SD card is the reguired one You may have to return the product to Vantron for maintenance if the updating of Bootloader adsload rom fails which may cause loss of time and money 2 Do not power off during updating 26 Vantron VT HMI 5101 4 2 3 Instructions for Windows CE Config uration Files Windows CE has two configuration files adsload hwt adsload reg that can be modified according to your own needs It is recommended to use configuration files with our technical support Instructions are