1. r E i Embec ded debris cannot be removed rcl NO YES Prior iiu h IED FIBER Before Embedding Debris 99 USER MANUAL WHERE INSPECTION SHOULD OCCUR Inspection of fiber end faces is CRITICAL at EVERY STAGE of handling fiber Connector Manufacturing Aircraft Assembly Maintenance ww e Harness Test Flight Line BOEING 787 FIBER INSPECTION AND CLEANING 9 INSPECT BULKHEAD Single Fiber Connectors INSPECT INSTALL TIP AND BARREL ASSEMBLY 1 Install the appropriate inspection tip and barrel assembly FBPP BAP1 to the probe microscope Note Standard tips require barrel assembly Inspection Barrel Assembly INSPECT BULKHEAD 2 Insert the probe into the bulkhead to inspect 3 Turn the focus control on the probe to focus the fiber image on the display 4 Determine whether clean or dirty Focus Control If clean do not touch it and CONNECT If dirty and if cleaning is required CLEAN 10 USER MANUAL INSPECT PATCH CORD Single Fiber Connectors INSPECT INSTALL TIP AND BARREL ASSEMBLY 1 Install the appropriate inspection tip and barrel assembly FBPP BAP1 to the probe microscope Note Standard tips require barrel assembly INSPECT PATCH CORD 2 Attach the patch cord to the probe microscope to inspect 3 Turn the focus control on the probe to focus the fiber
2. BOEING 787 FIBER INSPECTION AND CLEANING Inspect with FBP Probe and HD series Display Clean with CleanBlast System USER MANUAL ZP PKG 0554 REV 0 ii Notice Copyright Trademarks Patents Tested Equipment FCC Information European Union Independent Laboratory Testing Every effort was made to ensure that the information in this document was accurate at the time of printing However information is subject to change without notice and JDSU reserves the right to provide an addendum to this document with information not available at the time that this document was created Copyright 2010 JDSU LLC All rights reserved JDSU Enabling Broadband and Optical Innovation and its logo are trademarks of JDSU LLC All other trademarks and registered trademarks are the property of their respective owners No part of this guide may be reproduced or transmitted electronically or otherwise without written permission of the publisher JDSU is a trademark of JDSU in the United States and other countries CleanBlast is a registered trademark of JDSU RibbonDrive is a trademark of JDSU Hirose is a trademark of Hirose Electric Group MTP is a registered trademark of US Conec Ltd IBC is a trademark of US Conec Ltd Molex is a registered trademark of Molex Incorporated OptiTip and OptiTap are trademarks of Corning Incorporated Sony is a registered trademark of Sony Corporation Specifications terms
3. when using guides Align the ARINC alignment guide for plug FBPT A801 2001P and insert into either side of the receptacle pins or socket INSPECT 3 4 Insert the probe into the alignment guide to inspect Turn the focus control on the probe to focus the fiber image on the display Determine whether clean or dirty If clean do not touch it CONNECT If dirty and if cleaning is required CLEAN Note For Cleanliness Acceptance Criteria see the Aircraft Maintenance Manual AMM for the Boeing 787 BOEING 787 FIBER INSPECTION AND CLEANING INSPECT Barrel Assembly FBPP BAP3 shown Alignment Guide J 9 FBPT A801 2001P Focus Control HD1 Video Display 13 CLEAN COMMON METHODS Note For Cleanliness Acceptance Criteria see the Aircraft Maintenance Manual AMM for the Boeing 787 CLEAN BULKHEAD SWAB Use the swab to clean the bulkhead by inserting into bulkhead applying slight pressure and twisting the swab 2 to 3 times Inspect again and repeat if necessary Note Be sure to follow the recommended cleaning procedures defined in the Aircraft Maintenance Manual AMM CLEAN PATCH CORD REEL STYLE CLEANERS OR CLOTHS When cleaning with the reel style cleaners or cleaning cloths push the latch lever to expose the cleaning area cloth and wipe the patch cord end along
4. BE CLEANED from the end face prior to mating in order to optimize the efficiency of an optical signal or interconnect CleanBlast eliminates the user sensitivity and inconsistencies experienced with other cleaning tools by removing loose debris at the push of a button With more than 8 000 cleaning cycles between refills this automated system cleans faster more effectively and is less cost per clean than conventional methods Faster more effective and less cost per clean than using other methods Provides repeatable results e Eliminates user sensitivity e Removes instead of spreading loose debris from fiber optic end faces Cleans both patch cords and bulkheads e Multiple system configurations for a variety of applications e Clean multiple connector types by changing the precision cleaning tips 22 USER MANUAL BOEING 787 CONFIGURATIONS FBP 787 1 Boeing 787 Basic Avionics Inspection Kit Part Number Qty Description FBP HD1 HD1 Handheld Video Display 3 5 inch LCD FBP P5 H P5 Probe Video Inspection Probe 200 400X EMI Hardened 4 pin Out FBPT C130 Interface Tip for Standard Video Probe P5 for Use with Locking Guides FBPP BAP3 Barrel Assembly for P5 Probe Narrow Type for Use with Guides FBPP BAP3 A6 Barrel Assembly for P5 Probe Narrow Type w 60 Angle for Use with Guides FBPT A801 1002R Guide ARINC Type 1 Size 15 06 Shell Re
5. and Measurement Regional Sales NORTH AMERICA LATIN AMERICA ASIA PACIFIC EMEA www jdsu com inspect 1 SOO 228 5762 TEL 1 954 688 5660 TEL 852 2892 0990 IEIECEZOPAPIUIESOE 222 FAX 1 301 353 9216 FAX 1 954 345 4668 FAX 852 2892 0770 FAX 49 7181 86 1222 Product specifications and descriptions in this document subject to change without notice 2010 JDS Uniphase Corporation August 2010 ZP PKG 0554 REV 0
6. broad range of connector types located in The 4 pin connector output interfaces with the HD1 handheld video display The design of the FBP3 BLX probe incorporates an imaging system integrated light source video camera and focus mechanism The handle and barrel components of the probe are easily assembled and is powered by the HD1 display Handle Barrel m Focus Control 124 4pin Connection to HD1 Display FBP3 TIPS AND BARREL ASSEMBLY Tips and barrel assemblies such as the FBP3 C130 are specifically designed to work with the FBP3 long reach probe microscope and are typically used to inspect receptacles in the back tray of CCR cabinets de BOEING 787 FIBER INSPECTION AND CLEANING 21 CLEANBLAST SYSTEM OVERVIEW The patented JDSU CleanBlast fiber end face cleaning systems provide a fast effective and cost efficient solution for removing dirt and debris from connectors in most common applications CleanBlast is a non contact system that uses a highly filtered stream of pressurized gas with a vacuum circuit to create a high flow rate jet across the surface of the fiber A cleaning solvent is injected into the airflow and the contamination from the end face along with the solvent are then removed through the retrieval circuit The precise highly efficient non contact air solvent air stream blasts and removes loose debris with nearly 100 percent effectiveness CONTAMINATION MUST
7. image on the display 4 Determine whether clean or dirty If clean do not touch it and CONNECT If dirty and if cleaning is required CLEAN BOEING 787 FIBER INSPECTION AND CLEANING Inspection Tip Barrel Assembly Focus Control 11 INSPECT ARINC RECEPTACLE Mil Aero INSTALL BARREL ASSEMBLY TIP 1 Install the barrel assembly FBPP BAP3 or FBPP BAP3 A6 to the probe microscope Note No additional inspection tip is necessary when using guides 2 Align the ARINC alignment guide for receptacle FBPT A801 2002R and insert into either side of the receptacle pins or socket INSPECT 3 Insert the probe into the alignment guide to inspect 4 Turn the focus control on the probe to focus the fiber image on the display 5 Determine whether clean or dirty If clean do not touch it CONNECT If dirty and if cleaning is required CLEAN Note For Cleanliness Acceptance Criteria see the Aircraft Maintenance Manual AMM for the Boeing 787 12 INSPECT t Barrel Assembly FBPP BAP3 shown Alignment Guide FBPT A801 2002R Focus Control HD1 Video Display USER MANUAL INSPECT ARINC PLUG Mil Aero INSTALL BARREL ASSEMBLY TIP 1 Install the barrel assembly FBPP BAP3 or FBPP BAP3 A6 to the probe microscope Note No additional inspection tip is necessary
8. interchangeable and designed with a unique optics architecture that enables the probe to interface with every connector and application in your network INSPECT BEFORE YOU CONNECT Implementing a simple yet important process of proactively inspecting and cleaning before mating can prevent poor signal performance and equipment damage BENEFITS OF PROACTIVE INSPECTION Proactively inspecting fiber optic connectors will CONNECT 2 Reduce Aircraft On Ground Instances Reduce Troubleshooting Optimize Signal Performance Prevent Damage to Network Hardware I USER MANUAL FIBER OPTIC CONNECTORS SINGLE FIBER CONNECTORS Also called simplex connectors these types contain a single fiber located in the center of a ceramic zirconia ferrule The alignment of the mated connectors fibers is achieved inside a ceramic or bronze mating sleeve within the bulkhead adapter Body Houses the ferrule that secures the fiber in place utilizes a latch and key mechanism that aligns the LC Connector Core fiber and prevents the rotation of ferrules of two Cladding mated connectors Ferrule Ferrule Thin cylinder where the fiber is mounted that acts as the fiber alignment mechanism the end of the fiber is located at the end of the ferrule Fiber Cladding Glass layer surrounding the core that prevents the signal in the core from escaping Core The critical center layer of the
9. P BAP3 Barrel Assembly Narrow Type FBPT A801 1002R Guide ARINC Type 1 Size 15 06 Shell Receptacle w Pins FBPT A801 1002P Guide ARINC Type 1 Size 15 06 Shell Plug w Sockets FBPT A801 2001P Guide ARINC Type 2 F12 Plug w Pins FBPT A801 2001R Guide ARINC Type 2 F12 Receptacle w Sockets FBPT A801 2002R Guide ARINC Type 2 F12 Receptacle w Pins FBPT A801 2002P Guide ARINC Type 2 F12 Plug w Sockets FBPT A801 4001P Guide ARINC Type 4 12 Contact Plug w Pins FBPT A801 4001R Guide ARINC Type 4 12 Contact Receptacle w Sockets FBPP DPAC2 m md ee a re i re ee Md Converter Cable 4 pin Probe FBPT A801 4002P Boeing 787 In Flight Entertainment PANASONIC Inspection Tips Guide ARINC Type 4 36 Contact Plug w Pins FBPT A801 4002R Guide ARINC Type 4 36 Contact Receptacle w Sockets FBPT RQX8 P Boeing 787 In Flight Entertainment THALES Inspection Tips Tip Radiall Quadrax Size 8 Pin FBPT ROX8 S Tip Radiall Quadrax Size 8 Socket FBPT A801 1001R Guide ARINC Type 1 Size 13 04 Shell Receptacle w Pins FBPT A801 1001P 2 2 Guide ARINC Type 1 Size 13 04 Shell Plug w Sockets FCLT C130 1 Cleaning Tip for CleanBlast System Rugged for LUX24 Guides Miscellaneous Accessories BOEING 787 FIBER INSPECTION AND CLEANING 23 Test
10. UUUUEUUATUUUUUUUUS INPENUYUEPKTEN UY TUNE 2 eere ns Back Reflection 67 5 dB Back Reflection 65 3 dB 1 Back Reflection 32 5 dt Total Loss 0 250 d Total Loss 0 243 dB Total Loss 3 2 dE Back Reflection Total Loss 0 2 Back Reflection 32 5 dl Total Loss 3 2 d This OTDR trace illustrates a significant decrease in signal performance when dirty connectors are mated BOEING 787 FIBER INSPECTION AND CLEANING 7 INSPECT BEFORE YOU CONNECT INSPECT IS IT CLEAN THE SOLUTION INSPECT BEFORE YOU CONNECT e By implementing a simple yet important process of proactively inspecting and cleaning before mating you can prevent poor signal performance and CLEAN CONNECT equipment damage D qz PROACTIVE INSPECTION Loose debris and dirt are much easier to clean prior to mating the 2 connector sides By visually inspecting fiber connectors at every stage of dee before mating them idee are e in NM os ang equipment damage ors are er to clean mating before embedding debris into the fiber 5 REACTIVE INSPECTION If dirty connectors are not inspected and cleaned prior to mating dirt and debris can embed into the fiber surface causing Penne Mais de a after is discovered sa are taking a reactive approach B FIBER Prior Mating i N
11. and conditions are subject to change without notice All trademarks and registered trademarks are the property of their respective companies RibbonDrive Tips US Patent No 6 751 017 6 879 439 CleanBlast US Patent No 7 232 262 All pre qualification tests were performed internally at JDSU while all final tests were performed externally at an independent accredited laboratory This external testing guarantees the unerring objectivity and authoritative compliance of all test results JDSU s Commerce and Government Entities CAGE code under the North Atlantic Treaty Organization NATO is 018 3 Electronic test equipment is exempt from Part 15 compliance FCC in the United States Electronic test equipment is subject to the EMC Directive in the European Union The EN61326 standard prescribes both emission and immunity requirements for laboratory measurement and control equipment This unit has been tested and found to comply with the limits for a Class A digital device This unit has undergone extensive testing according to the European Union Directive and Standards CONTENTS Introduction to Fiber Inspection Fiber Optic Connectors Mil Aero Connectors Effect on Signal Performance Inspect Before You Connect Where Inspection Should Occur Inspect Clean Connect FBP Probe Microscope Inspection Tips Guides Barrel Assemblies Tips Guides and Barrel Assemblies Map HD1 Video Display FBP3 Long Reach Prob
12. can also be used with the JDSU CleanBlast system to clean away debris and dirt from the optical end faces of ARINC 801 connectivity 6 Receptacle Alignment Guide FBP Probe Microscope Socket USER MANUAL EFFECT ON SIGNAL PERFORMANCE THE PROBLEM Dirt is everywhere and a typical dust particle 2 15 um in diameter can significantly affect signal performance and cause permanent damage to the fiber end face Most field test failures can be attributed to dirty connectors and most of them are not inspected until the problem is detected after permanent damage has already occurred ER dirt E get on the core surface light becomes blocked creating unacceptable insertion loss and Furthermore these contamination particles can permanently damage the glass interface by digging into the glass and leaving pits when mated causing further signal loss Damage also occurs when large particles of dirt on the cladding layer and or the ferrule cause barriers that prevent physical contact creating air gaps between the fiber connection These large particles are also known to break apart and migrate across the fiber surface when mated Light Transmitted Core Cladding DIRTY CONNECTION FIBER CONTAMINATION AND ITS EFFECT ON SIGNAL PERFORMANCE 1310 nm 8126VLR IOR 1 46600 OTDR_tracel 0 59 8 7 004 dB B 220 00 m 17 175 dB A B 220 00 m 8 171 dB 25 807 dB m dB 77 UUREUUUURUUUUUUAAU
13. ceptacle w Pins FBPT A801 1002P Guide ARINC Type 1 Size 15 06 Shell Plug w Sockets FBPT A801 4001P Guide ARINC Type 4 12 Contact Plug w Pins FBPT A801 2001P Guide ARINC Type 2 F12 Plug w Pins FBPT A801 2001R Guide ARINC Type 2 F12 Receptacle w Sockets FBPT A801 2002R Guide ARINC Type 2 F12 Receptacle w Pins FBPT A801 2002P Guide ARINC Type 2 F12 Plug w Sockets FBPT LUX24 G001 Guide LUXCIS 24 In Line Plug w Sockets FBPT LUX24 G002 Guide LUXCIS 24 In Line Receptacle w Pins FBPT U12M Tip Universal 1 25 mm Patch Cord FBPT U25M Tip Universal 2 5 mm Patch Cord FBPT SC Tip SC Bulkhead FBPT LC Tip LC Bulkhead FBPP HSC15 Pelican 1550 Case with Custom Foam for 787 Kit 51 Case with Dividers for Boeing 787 Guides FBPP TACS2 Tip Case with Foam for Boeing 787 Tips and Barrel Assemblies FBP 787 CCR Boeing 787 CCR Cabinet Long Reach Upgrade Kit FBP3 P3L 1 P3 Probe Video Inspection Probe Long Reach Handle and Barrel FBP3 C130 1 Interface Tip for Long Reach Video Probe P3 for Use with Locking Guides FCL ARINC 01 Inspection and Cleaning Kit ARINC FCL P1102 CleanBlast Portable System Digital FCLT BAP3 125 Cleaning Tip ARINC Guides FBP P5 P5 Probe Video Inspection Probe 200 400X 4 pin Out FBP
14. e and Tips JDSU CleanBlast System Boeing 787 Configurations BOEING 787 FIBER INSPECTION AND CLEANING Fiber Inspection Overview Inspect Before You Connect 4 Benefits of Proactive Inspection u Single Fiber Connectors 5 ARINC 8 their anna cad 6 etin mailto in duin iu nerit n 6 JDSU Alignment 6 The Problem ttem atate m orn The dat don nolite 8 Proactive Inspection vs Reactive 8 Inspect at Every Stage of Handling 9 Inspect Bulkhead Single Fiber 10 Inspect Patch Cord Single Fiber Connectors 11 Inspect ARINC Receptacle Mil Aero 12 Inspect ARINC Plug 2 2 1208 se 13 Clean Common Methods 14 Clean JDSU CleanBlast System 15 Good Fiber Connection 16 FBP Probe Overview tnnt 17 Specifications tette nnns 17 Inspection Tips and Guides sss 18 6 18 Tips Guide Installation Guide 19 HD1 Display Overview tte 20 Specifications asacas
15. eo out of the probe A conversion cable is also Shut down available for 6 pin QuickCapture analog probes ida FEATURES MM Hanging ER e 3 5 inch TFT LCD display Accessory Contrast control adjustment e Rechargeable Sony Li ion battery with 2 hours continuous run time extended when using i emovable auto shutoff feature Magnet Battery gauge LED showing remaining battery life Built in hanging accessory for hands free operation Rechargeable Li on Battery Specifications Dimensions 45 7 x 43 2 x 140 mm Weight 400g Video display 3 5 inch TFT LCD Connectors 4 pin for FBP probe microscopes pi AC Power Battery life 2 hours continuous use bn grad Input Charging time 2 hours 20 USER MANUAL FBP3 LONG REACH PROBE AND TIPS FBP3 PROBE OVERVIEW As system capacities have increased optical connectors have proliferated in backplane applications Increasingly those connectors are ribbon ferrule based The FBP3 series is purpose built for reaching between adjacent cards modules to reach optical connectors in the backplane The is a long reach backplane probe that is designed to inspect connectors that are otherwise difficult to access Its unique and complimentary design allows the probe to fit down a channel less than 1 inch wide making the inspectiOn of backplanes convenient and functional The Universal Adapter is compatible with all standard FBPT series inspection tips This allows the probe to inspect a
16. fect Core Alignment 2 Physical Contact 3 Pristine Connector Interface Light Transmitted Cladding Core Clean Connection Today s connector design and production techniques have eliminated most of the challenges to achieving core alignment and physical contact What remains challenging is maintaining a pristine end face As a result CONTAMINATION is the 1 reason for troubleshooting optical networks Systematic and Proactive Inspection is the only way to ensure that the connectors are truly clean before mating them INSPECT BEFORE YOU CONNECT 16 USER MANUAL FBP PROBE MICROSCOPE FBP PROBE OVERVIEW JDSU FBP series probes are portable video microscopes used to inspect fiber optic connectivity While most fiber microscopes are limited to inspecting male connectors JDSU s FBP probe is designed to inspect both simplex and multi fiber ribbon types of both male and female connectors as well as optical devices such as transceivers The probe is specially designed to fit and operate comfortably and easily in hand allowing the user to inspect hard to reach connectors that are installed on the backside of patch panels or inside hardware devices This eliminates the need to disassemble hardware devices prior to inspection Focus Control Inspection Tip Barrel Assembly CONTROLS The focus control on the probe allows the user to adjust focus manually of the live fiber end face
17. fiber the conduit that light passes through Fiber Ferrule Alignment Sleeve Fiber Connection Simplex Physical Contact BOEING 787 FIBER INSPECTION AND CLEANING 5 MIL AERO CONNECTORS ARINC 801 Mil Aero connectors are fiber optic connectors used in aerospace applications Established by the Airlines Electronic Engineering Committee AEEC ARINC 801 is part of the ARINC 800 series of fiber optic standards for avionics networking All ARINC 801 connectors utilize a 1 25 mm ferrule and are mated in a pin and socket configuration While all of the ARINC 801 connectors utilize a plug and receptacle design there are different design types within the standard KEY TERMS Plug The male interface of an ARINC 801 connection Receptacle The female interface of an ARINC 801 connection Pin The exposed 1 25 mm ferrule Socket The unexposed ferrule inside the alignment sleeve JDSU ALIGNMENT GUIDES JDSU offers a series of alignment guides that fit the shell sizes of the respective plug and receptacle of various ARINC 801 connectors These guides provide a compatible interface for the inspection and cleaning of pins or sockets specific to each type of connector With the JDSU FBP probe microscope and handheld video display JDSU s ARINC 801 alignment guides provide the means for a quick and easy inspection of these rugged multi termini connectors in a field or factory environment In addition these guides
18. image on the display The magnification control available only on dual magnification probes allows the user to switch between LOW and HIGH magnifications of the fiber end face image BOEING 787 FIBER INSPECTION AND CLEANING Specifications Dimensions Weight Optical magnification Focus control Cord length Connector Camera type Video output Light source Lighting technique Power source Magnification Control 140 x 46 x 43 mm 5 5 x 1 8 x 1 7 in 180 g 6 3 oz 200X 400X 200 400X Adjustable in probe 240 cm 94 in 4 Hirose male 1 3 in CMOS Sensor NTSC or PAL Blue LED 100 000 hour life Coaxial From the display device or USB module 17 JDSU INSPECTION TIPS GUIDES BARREL ASSEMBLIES INSPECTION TIPS AND GUIDES To optimize the performance and safety of fiber inspection the probe microscope is used in conjunction with various interchangeable tips and guides Each tip or guide is specifically designed to accessibility and accurate inspection for every connector on the aircraft without causing harm to the connections Standard Bulkhead Tips Standard bulkhead tips allow the user to inspect the fiber end face on the female side of FBPT SC the bulkhead e g inside hardware devices or on the back side of patch panels FBPT U25M Standard Bulkhead Tips Standard patch cord tips allow inspection of male ends of a fiber connection e g patch cords pigtail
19. isanteieiguidiiviternadinsstumcRis quisa idartiviis 20 FBP3 Probe Overview tte 21 FBP3 Tips and Barrel 21 CleanBlast System Overview 22 Configurations Table ttt 23 iii INTRODUCTION TO FIBER INSPECTION FIBER INSPECTION OVERVIEW Contamination is the number 1 reason for troubleshooting optical networks single particle mated into the core of a fiber can cause significant back reflection insertion loss and equipment damage Visual inspection is the only way to determine if fiber connectors are truly clean before mating them The JDSU video fiber inspection probe and handheld display system is used to quickly and easily inspect connector end faces which ultimately minimizes signal loss and optimizes test conditions FBP series video probes are dual magnification 200 400X high performance handheld microscopes designed for inspecting both female bulkhead and male patch cord connectors The probe microscope can also be combined with a USB converter module to inspect connectors via compatible test platforms and PC laptop This versatile system offers a wide range of configurable solutions that can meet the demands of any application Our comprehensive selection of precision stainless steel fiber inspection tips adapters and guides are carefully engineered to produce consistent and accurate results They are
20. s Universal tips include the FBPT U25M compatible with 2 5 mm ferrules e g FC SC ST and the FBPT U12M used to inspect 1 25 mm ferrules e g LC MU Alignment Guides Alignment guides enable the inspection of various military and aerospace connectors that use a plug and receptacle design In addition to providing an alignment channel for sockets these alignment guides work in conjunction with a barrel assembly to prevent FBPT A801 2001R the pins from breaking BARREL ASSEMBLIES The barrel assembly houses the objective lens and I men Yen works in conjunction with various FBPT inspection tips and alignment guides FBPP BAP1 FBPP BAP3 FBPP BAP3 A6 18 USER MANUAL TIPS GUIDES AND BARREL ASSEMBLIES MAP TIPS GUIDE INSTALLATION GUIDE FBPT Inspection Tips Barrel Assembly m Lamy Standard Patch Cord Tips FBPP BAP1 Standard Bulkhead Tips Alignment Guides FBP Probe Microscope FBPP BAP1 Attach this barrel assembly directly onto the P5 probe and use with the various inspection tips for inspecting fiber connectors FBPP BAP3 Attach this barrel assembly directly onto the P5 probe and use with FBPP BAP3 A6 the various alignment guides for inspecting avionics fiber Typical Use Inspecting the connectors Tray side of the AGU FBPP BAP3 A6 Attach this angled narrow barrel assembly directly onto the P5 probe and use with the various E T alignment guide
21. s for inspecting avionics fiber connectors The 60 degree angle allows access into tight areas such as the AGU tray FBPT C130 FBPT C130 Attach this tip directly onto the P5 Typical Use Inspecting the probe and use with select align Receptacle in the back tray ment guides of a CCR Cabinet FBP3 C130 Attach this tip on the end o the Long Reach Video Probe P3 for use with select alignment guides Alignment Guides FBP3 C130 FBP3 Long Reach Probe Microscope Typical Use Inspecting the Receptacle in the back tray of a CCR Cabinet BOEING 787 FIBER INSPECTION AND CLEANING 19 HD1 VIDEO DISPLAY HD1 DISPLAY OVERVIEW The JDSU HD1 Video Display is a durable 3 5 inch TFT lightweight ergonomic drop tested display for use LCD Screen with any NTSC FBP or FBP3 series probe It features a 3 5 inch TFT active matrix LCD screen which produces a bright clear and crisp high contrast image of the ee fiber end face It can be powered by 100 240V AC or a rechargeable Li on battery the Li on battery must be in the display for the unit to operate The HD1 Display features contrast adjustment auto shutoff function Battery Power AC Power LED LED to preserve battery life and a hanging accessory for hands free operation The display uses a 4 pin Hirose Auto Shut down Battery Interval and Status and connector which routes power into the probe and Auto Contrast Control vid
22. the cleaning cloth in the direction of the indicated arrow 2 to 3 times Note Be sure to follow the recommended cleaning procedures defined in the Aircraft Maintenance Manual AMM REUSEABLE CLEANING STICK Reuseable cleaning sticks clean both the bulkhead and patch cord sides 14 USER MANUAL CLEAN JDSU CLEANBLAST SYSTEM CLEANING WITH CLEANBLAST To clean receptacles with the CleanBlast system 1 install the appropriate cleaning tip to the CleanBlast handset 2 PRIMEthe nozzle if necessary see CleanBlast User Manual 3 Align the alignment guide and insert into either side of the receptacle or plug pins or socket Insert the handset into the alignment guide and push to disengage safety mechanism the POWER READY light will turn green and press the run button to initiate cleaning 5 INSPECT the receptacle or plug 6 Determine whether clean or dirty If clean do not touch it and CONNECT If dirty repeat CLEAN Note Embedded mated debris cannot be cleaned and bonded burned debris must be physically cleaned before using CleanBlast BOEING 787 FIBER INSPECTION AND CLEANING Run Button X Cleaning Tip Alignment Guide 1 FBPT A801 2002R Focus Control 15 CONNECT GOOD FIBER CONNECTION There are 3 basic principles that are critical to achieving an efficient fiber optic connection 1 Per

Download Pdf Manuals

image

Related Search

Related Contents

VGN-SZ140PC  MySQL Utilities - MySQL Community Downloads  Infocus IN5544 data projector  Millimess--2100--3756635--BA--DE-EN--2010-08-01  MORTIER 798 - Parexlanko  ALASBO Power Lunch  ProForm 380x User's Manual  Cirrus - Instrumentcompaniet AS  LG DLE2301R Accessories Catalogue  Archos Arnova 10 8GB Black  