1. 1171 0000 52 06 Page 6 Basic Safety Instructions Should a fire occur the product may release hazardous substances gases fluids etc that can cause health problems Therefore suitable measures must be taken e g protective masks and protective clothing must be worn Laser products are given warning labels that are standardized according to their laser class Lasers can cause biological harm due to the properties of their radiation and due to their extremely concentrated electromagnetic power If a laser product e g a CD DVD drive is integrated into a Rohde amp Schwarz product absolutely no other settings or functions may be used as described in the product documentation The objective is to prevent personal injury e g due to laser beams EMC classes in line with CISPR 11 Class A Equipment suitable for use in all environments except residential environments and environments that are directly connected to a low voltage supply network that supplies residential buildings Class B Equipment suitable for use in residential environments and environments that are directly connected to a low voltage supply network that supplies residential buildings Repair and service 1 The product may be opened only by authorized specially trained personnel Before any work is performed on the product or before the product is opened it must be disconnected from the AC supply network Otherwise personnel will be exposed
2. Para evitar da os personales o da os en el producto siga las instrucciones de seguridad del fabricante del medio de transporte o elevaci n utilizado 1171 0000 52 06 Page 18 Instrucciones de seguridad elementales 3 Si se utiliza el producto dentro de un veh culo recae de manera exclusiva en el conductor la responsabilidad de conducir el veh culo de manera segura y adecuada El fabricante no asumir ninguna responsabilidad por accidentes o colisiones No utilice nunca el producto dentro de un veh culo en movimiento si esto pudiera distraer al conductor Asegure el producto dentro del veh culo debidamente para evitar en caso de un accidente lesiones u otra clase de da os Eliminaci n protecci n del medio ambiente 1 Los dispositivos marcados contienen una bater a o un acumulador que no se debe desechar con los residuos dom sticos sin clasificar sino que debe ser recogido por separado La eliminaci n se debe efectuar exclusivamente a trav s de un punto de recogida apropiado o del servicio de atenci n al cliente de Rohde amp Schwarz Los dispositivos el ctricos usados no se deben desechar con los residuos dom sticos sin clasificar sino que deben ser recogidos por separado Rohde amp Schwarz GmbH amp Co KG ha elaborado un concepto de eliminaci n de residuos y asume plenamente los deberes de recogida y eliminaci n para los fabricantes dentro de la UE Para desechar el producto de manera respetuosa con el
3. 01 7 R amp S RT ZD01 Product Description 1 4 Precautions Precautions Shock hazard caused by high voltages To avoid electric shock and personal injury and to prevent damage to the probe or any other products connected to it observe the following instructions 1 5 The probe and the measurement instrument must be grounded The probe is grounded with the shell of the BNC connector or an auxiliary ground connector through the grounding of the measurement instrument Never use the probe in measurement environments higher than measure ment category Ill Do not apply effective voltages greater than 1000 V RMS between either input of the probe and earth ground or between both inputs Make sure that all accessories comply with measurement category III 1000 V RMS Do not operate the probe without covers Do not use the probe in wet damp or explosive atmospheres Make sure that the surface of the probe is completely dry before connect ing the inputs Avoid exposed circuitry Do not touch exposed connections and compo nents when power is on Remove jewelry watches and other metallic objects Do not operate the probe if any part is damaged or with suspected failures If you detect or suspect any damage to the probe have it inspected by qualified service personnel Unpacking the Instrument The following items are included in the delivery e R amp S RT ZD01 high voltage differential probe e Carrying case e Sprung
4. 06 Page 12 Instrucciones de seguridad elementales Estados operativos y posiciones de funcionamiento El producto solamente debe ser utilizado seg n lo indicado por el fabricante respecto a los estados operativos y posiciones de funcionamiento sin que se obstruya la ventilaci n Si no se siguen las indicaciones del fabricante pueden producirse choques el ctricos incendios y o lesiones graves con posible consecuencia de muerte En todos los trabajos deber n ser tenidas en cuenta las normas nacionales y locales de seguridad del trabajo y de prevenci n de accidentes 1 Si no se convino de otra manera es para los productos Rohde amp Schwarz v lido lo que sigue como posici n de funcionamiento se define por principio la posici n con el suelo de la caja para abajo modo de protecci n IP 2X uso solamente en estancias interiores utilizaci n hasta 2000 m sobre el nivel del mar transporte hasta 4500 m sobre el nivel del mar Se aplicar una tolerancia de 10 sobre el voltaje nominal y de 5 sobre la frecuencia nominal Categor a de sobrecarga el ctrica 2 ndice de suciedad 2 2 No sit e el producto encima de superficies veh culos estantes o mesas que por sus caracter sticas de peso o de estabilidad no sean aptos para l Siga siempre las instrucciones de instalaci n del fabricante cuando instale y asegure el producto en objetos o estructuras p ej paredes y estantes Si se realiza la instalaci n de modo distinto al
5. Calibration Intervall cccceeceeceeceeceececceceeceeceeseeeseeseeceseeueeeseuseeeaneass 29 5 Functional Check AA AA KEAREII EAE AERRENRK uA AERE 30 To gt PROPERE PT 32 R amp S RT ZD01 Product Description Key Features and Key Characteristics 1 Product Description 1 1 Key Features and Key Characteristics The R amp S RT ZD01 high voltage differential probe is designed to safely measure high voltage floating circuits using a grounded oscilloscope The probe extends the measurement capability of oscilloscopes in measuring electronic power converters inverters motor speed controls switch mode power supplies and many other appli cations The R amp S RT ZD01 high voltage differential probe conforms to the safety require ments for CAT Ill measurement instruments and pollution degree 2 according to IEC 61010 The maximum working voltage is 1000 V RMS between each input lead and earth ground This limit applies for all attenuation settings 1 2 Measurement Categories To ensure safe operation of measurement instruments IEC 61010 2 030 defines particular safety requirements for testing and measuring circuits The standard introduces measurement categories that rate instruments on their ability to resist short transient overvoltages that occur in addition to the working voltage of the instrument and can exceed the working voltage many times over Measurement categories are distinguished as follows e O Instruments without
6. Cleaning 4 3 Cleaning To clean the exterior of the probe use a soft cloth moistened with either distilled water or isopropyl alcohol Before using the probe again make sure to dry it com pletely Instrument damage caused by cleaning agents Cleaning agents contain substances that may damage the instrument for example solvent may damage the labeling or plastic parts Never use cleaning agents such as solvents thinners acetone etc acids bases or other substances 4 4 Calibration Interval The recommended calibration interval is two years For servicing send the probe to your nearest Rohde amp Schwarz service center See chapter 4 2 Returning the Probe for Servicing on page 28 EIM User Manual 1422 0732 02 01 29 R amp S RT ZD01 Functional Check 5 Functional Check The functional check is used to confirm the basic operation of the R amp S RT ZD01 high voltage differential probe using simple measurement equipment The functional check is not suitable for verifying compliance with the probe speci fications since the test results are influenced by the oscilloscope used ER I BS 0805 D Baje o A S 30 User Manual 1422 0732 02 01 R amp S RT ZD01 Functional Check Set the att
7. como p ej al desplazarlo de un lugar fr o a otro caliente La entrada de agua aumenta el riesgo de choque el ctrico 18 Antes de la limpieza desconecte por completo el producto de la alimentaci n de tensi n p ej red de alimentaci n o bater a Realice la limpieza de los aparatos con un pa o suave que no se deshilache No utilice bajo ning n concepto productos de limpieza qu micos como alcohol acetona o diluyentes para lacas nitrocelul sicas 1171 0000 52 06 Page 15 Instrucciones de seguridad elementales Funcionamiento 1 El uso del producto requiere instrucciones especiales y una alta concentraci n durante el manejo Debe asegurarse que las personas que manejen el producto est n a la altura de los requerimientos necesarios en cuanto a aptitudes f sicas ps quicas y emocionales ya que de otra manera no se pueden excluir lesiones o da os de objetos El empresario u operador es responsable de seleccionar el personal usuario apto para el manejo del producto Antes de desplazar o transportar el producto lea y tenga en cuenta el capitulo Transporte Como con todo producto de fabricaci n industrial no puede quedar excluida en general la posibilidad de que se produzcan alergias provocadas por algunos materiales empleados los llamados al rgenos p ej el n quel Si durante el manejo de productos Rohde amp Schwarz se producen reacciones al rgicas como p ej irritaciones cut neas estornudos conti
8. contact one of our Customer Support Centers A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation programming or applications of Rohde amp Schwarz equipment Up to date information and upgrades To keep your instrument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care that you will get the right information Europe Africa Middle East Phone 49 89 4129 12345 customersupport rohde schwarz com North America Phone 1 888 TEST RSA 1 888 837 8772 customer support rsa rohde schwarz com Latin America Phone 1 410 910 7988 customersupport la rohde schwarz com Asia Pacific Phone 65 65 13 04 88 customersupport asia rohde schwarz com China Phone 86 800 810 8228 86 400 650 5896 customersupport china rohde schwarz com ROHDE amp SCHWARZ 1171 0500 22 06 00 R amp S RT ZD01 Contents Contents 1 Product DeScrIpUOP ies ocaeca aria ida id 5 1 1 Key Features and Key CharacteristiCS rrrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnn 5 1 2 Measurement Categories ccccccccceeeeeseeeeeeeeeeeeeeseeeseeeeeeeeeeseneeeeeeeees 5 1 3 Pollution Degrees aa nadia 6 14 Preca auti nS caspase cnn ci emcees G 8 1 5 Unpacking the InstruMent coooonnnnnnnn
9. delivered on the service kit CD ROM All service accessories and items can be ordered from your Rohde amp Schwarz service center R amp S RT ZD01 Putting into Operation Connecting the Probe to R amp S Oscilloscopes 2 Putting into Operation 2 1 Connecting the Probe to R amp S Oscilloscopes Shock hazard caused by high voltages To avoid electric shock and personal injury and to prevent damage to the probe or any other products connected to it make sure that the shell of the BNC output connector is safely connected to earth ground Never connect the probe to the DUT before grounding is ensured Usually the outer cable of the measuring instrument is connected to protec tive ground and ensures the grounding of the instrument and the probe If the probe is used together with an ungrounded instrument the auxiliary ground connector 4 mm banana plug must be used to ground the probe Avoiding measurement errors The probe must only be connected to measuring instruments with high impe dance signal input at least 10 kQ termination Do not use instruments that have only 50 Q terminated inputs 1 Connect the BNC output connector to an input channel of the oscilloscope Turn the collar until it clicks and check that it is locked securely 2 Make sure that the measuring instrument and the probe are grounded If you use a measuring instrument without grounded input use the auxiliary ground connector to ground t
10. hooks black and red E User Manual 1422 0732 02 01 8 R amp S RT ZD01 Product Description Unpacking the Instrument e USB power cord e User manual e R amp S RT Zxx data sheet e Calibration certificate e Documentation of calibration values if ordered B GG menia aeo wA OSCILLOSCOPE ACCESSORY gt Fig 1 2 R amp S RT ZD01 probe with accessories 1 5 4 Inspecting the Contents e Inspect the package for damage Keep a damaged package and the cushioning material until the contents have been checked for completeness and the instrument has been tested If the packaging material shows any signs of stress notify the carrier as well as your Rohde amp Schwarz service center Keep the package and cushioning mate rial for inspection e Inspect the probe If there is any damage or defect or if the R amp S RT ZD01 high voltage differential probe does not operate properly notify your Rohde amp Schwarz service center e Inspect the accessories If the contents are incomplete or damaged notify your Rohde amp Schwarz service center Accessories supplied with the instrument are listed in chapter 1 7 Accessories and Items on page 14 SS SSeS SSS SSS 7 T TlTlfffrc XA User Manual 1422 0732 02 01 9 R amp S RT ZD01 Product Description Description of the Probe 1 6 Description of the Probe
11. indicado en la documentaci n del producto se pueden causar lesiones o en determinadas circunstancias incluso la muerte 3 No ponga el producto sobre aparatos que generen calor p ej radiadores o calefactores La temperatura ambiente no debe superar la temperatura m xima especificada en la documentaci n del producto o en la hoja de datos En caso de sobrecalentamiento del producto pueden producirse choques el ctricos incendios y o lesiones graves con posible consecuencia de muerte Seguridad el ctrica Si no se siguen o se siguen de modo insuficiente las indicaciones del fabricante en cuanto a seguridad el ctrica pueden producirse choques el ctricos incendios y o lesiones graves con posible consecuencia de muerte 1 Antes de la puesta en marcha del producto se deber comprobar siempre que la tensi n preseleccionada en el producto coincida con la de la red de alimentaci n el ctrica Si es necesario modificar el ajuste de tensi n tambi n se deber n cambiar en caso dado los fusibles correspondientes del producto 1171 0000 52 06 Page 13 Instrucciones de seguridad elementales Los productos de la clase de protecci n con alimentaci n m vil y enchufe individual solamente podr n enchufarse a tomas de corriente con contacto de seguridad y con conductor de protecci n conectado Queda prohibida la interrupci n intencionada del conductor de protecci n tanto en la toma de corriente como en el mismo producto La
12. rated measurement category For measurements performed on circuits not directly connected to mains for example electronics circuits powered by batteries and specially protected sec ondary circuits This measurement category is also known as CAT I e CAT Il For measurements performed on circuits directly connected to the low voltage installation by a standard socket outlet for example household appliances and portable tools e CAT Ill For measurements performed in the building installation such as junction boxes circuit breakers distribution boards and equipment with permanent connection to the fixed installation M SSS User Manual 1422 0732 02 01 5 R amp S RT ZD01 Product Description Pollution Degrees e CAT IV For measurements performed at the source of the low voltage installation such as electricity meters and primary overcurrent protection devices Low voltage High voltage 0 CATI I 1 Power supply Wall socket Main fuse Transformer Fig 1 1 Examples of measurement categories The higher the category the higher the expected transient overvoltage Overvol tages can overload a circuit and cause electrical and physical damage Therefore use the measurement instrument only in electrical environments for which the instrument is rated The measurement categories correspond to the overvoltage categories of the IEC60664 standards Working voltages stated in context with measurement cate gories are alw
13. 1 6 1 Parts of the probe The R amp S RT ZD01 consists of the probe amplifier box an output lead and two input leads Fig 1 3 R amp S RT ZD01 probe 1 Probe amplifier box 2 Input leads 3 Safety banana plug 4 mm 4 Sprung hooks 5 Output lead 6 BNC output connector 7 Auxiliary ground connector SSS ee User Manual 1422 0732 02 01 10 R amp S RT ZD01 Product Description Description of the Probe Probe amplifier box Contains the high voltage divider the active differential amplifier and other elec tronic components All components are designed to ensure safe operation at haz ardous contact voltages within the specified working voltage and measurement category In particular all air gaps and creeping distances comply with all current safety standards to protect the user the measurement object and the probe against any harm or damage The active differential amplifier takes the difference between the positive and neg ative signal input voltages The probe transfers this difference signal to the oscillo scope Common mode voltages are rejected The controls and indicators of the amplifier box are described in chapter 1 6 2 Controls and Indicators on page 12 Output lead Connects the amplifier box to the oscilloscope or other measurement instruments using aBNC connector Its length of 90 cm allows for a comfortable wor
14. R amp SRT ZDO1 High Voltage Differential Probe User Manual JADE AAR ALSO 1422 0732 02 01 c ab EB o gt gt e D O D 215 o D Test 8 M This User Manual describes the following R amp S RT ZD models and options e R amp S RT ZD01 1422 0703 02 2012 Rohde amp Schwarz GmbH amp Co KG Muehldorfstr 15 81671 Munich Germany Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 E mail info rohde schwarz com Internet http www rohde schwarz com Printed in Germany Subject to change Data without tolerance limits is not binding R amp S is a registered trademark of Rohde amp Schwarz GmbH amp Co KG Trade names are trademarks of the owners The following abbreviations are used throughout this manual R amp S RT ZD01 is abbreviated as R amp S RT ZD01 R amp S9RTO is abbreviated as R amp S RTO Basic Safety Instructions Always read through and comply with the following safety instructions All plants and locations of the Rohde amp Schwarz group of companies make every effort to keep the safety standards of our products up to date and to offer our customers the highest possible degree of safety Our products and the auxiliary equipment they require are designed built and tested in accordance with the safety standards that apply in each case Compliance with these standards is continuously monitored by our quality assurance system The product described here has been des
15. and the common mode input voltage is totally supressed 3 1 Common Mode Rejection Ratio CMRR An deal differential probe outputs a voltage that depends only on the differential input voltage Vi between positive and negative input and suppresses the common mode voltages This is equivalent to an infinite common mode rejection ratio CMRR In contrast real probes have a finite CMRR resulting in a small part of the common mode voltage visible in the output signal The CMRR is defined as the ratio of the amplifications of differential and common mode input signals CMRR ram cm Example If a differential input voltage of 1 V yields an output voltage of 10 mV Ayam 0 01 and a common mode input voltage of 1 V an output voltage of 0 1 mV Avcom 0 0001 the CMRR is 100 or 40 dB A high CMRR is important if significant common mode signals are encountered at the probe input for example e DC voltages for setting the operating points of active DUTs e Different ground levels of probe and DUT e g floating DUTs e An interference that couples equally to both conductors of a differential trans mission line Se e User Manual 1422 0732 02 01 24 R amp S RT ZD01 Characteristics of Differential Probes Dynamic Range and Operating Voltage Window e Probing on ground referenced signals In this case the common mode compo nent is always equal to half of the input voltage 3 2 Dynamic Range and Operating Voltage Wind
16. applications It is therefore essential to make sure that the signal words described here are always used only in connection with the related product documentation and the related product The use of signal words in connection with unrelated products or documentation can result in misinterpretation and in personal injury or material damage Operating states and operating positions The product may be operated only under the operating conditions and in the positions specified by the manufacturer without the product s ventilation being obstructed If the manufacturer s specifications are not observed this can result in electric shock fire and or serious personal injury or death Applicable local or national safety regulations and rules for the prevention of accidents must be observed in all work performed 1 Unless otherwise specified the following requirements apply to Rohde amp Schwarz products predefined operating position is always with the housing floor facing down IP protection 2X use only indoors max operating altitude 2000 m above sea level max transport altitude 4500 m above sea level A tolerance of 10 shall apply to the nominal voltage and 5 to the nominal frequency overvoltage category 2 pollution severity 2 1171 0000 52 06 Page 3 Basic Safety Instructions Do not place the product on surfaces vehicles cabinets or tables that for reasons of weight or stability are unsuitable for this purpose Always fol
17. artes relevantes para la seguridad deber realizarse un control de seguridad control a primera vista control del conductor de protecci n medici n de resistencia de aislamiento medici n de la corriente de fuga control de funcionamiento Con esto queda garantizada la seguridad del producto Bater as y acumuladores o celdas Si no se siguen o se siguen de modo insuficiente las indicaciones en cuanto a las bater as y acumuladores o celdas pueden producirse explosiones incendios y o lesiones graves con posible consecuencia de muerte El manejo de bater as y acumuladores con electrolitos alcalinos p ej celdas de litio debe seguir el est ndar EN 62133 1171 0000 52 06 Page 17 Instrucciones de seguridad elementales 1 No deben desmontarse abrirse ni triturarse las celdas 2 Las celdas o baterias no deben someterse a calor ni fuego Debe evitarse el almacenamiento a la luz directa del sol Las celdas y baterias deben mantenerse limpias y secas Limpiar las conexiones sucias con un pa o seco y limpio 3 Las celdas o bater as no deben cortocircuitarse Es peligroso almacenar las celdas o bater as en estuches o cajones en cuyo interior puedan cortocircuitarse por contacto rec proco o por contacto con otros materiales conductores No deben extraerse las celdas o bater as de sus embalajes originales hasta el momento en que vayan a utilizarse 4 Las celdas o bater as no deben someterse a impactos mec nicos fuertes ind
18. arz products this will be indicated at the appropriate place in the product documentation Keep the basic safety instructions and the product documentation in a safe place and pass them on to the subsequent users Observing the safety instructions will help prevent personal injury or damage of any kind caused by dangerous situations Therefore carefully read through and adhere to the following safety instructions before and when using the product It is also absolutely essential to observe the additional safety instructions on personal safety for example that appear in relevant parts of the product documentation In these safety instructions the word product refers to all merchandise sold and distributed by the Rohde amp Schwarz group of companies including instruments 1171 0000 52 06 Page 1 Basic Safety Instructions systems and all accessories For product specific information see the data sheet and the product documentation Symbols and safety labels Meaning Symbol Meaning Notice general danger location O ON OFF supply voltage Observe product documentation Caution when handling heavy Standby indication equipment Danger of electric shock Direct current DC Warning Hot surface Alternating current AC Protective conductor terminal Direct alternating current DC AC Ground Device fully protected by double reinforced insulation Ground terminal EU labeling for batteries a
19. ays specified as effective voltages V RMS against earth ground 1 3 Pollution Degrees The pollution degree classifies the amount of dry pollution and condensation that may occur in the environment Products must be used only in the environment for which they are rated e Pollution Degree 1 No pollution or only dry nonconductive pollution occurs The pollution has no effect Products of this category are generally encapsulated hermetically sealed or used only in clean rooms e Pollution Degree 2 Normally only dry nonconductive pollution occurs Occasionally a temporary conductivity that is caused by condensation must be expected Temporary con ETR U BMEBEENENNNN NNUS User Manual 1422 0732 02 01 6 R amp S RT ZD01 Product Description Pollution Degrees densation occurs only when the product is out of service The typical location is an office laboratory or home environment e Pollution Degree 3 Conductive pollution or dry nonconductive pollution that becomes conductive due to condensation The typical environment are sheltered locations where neither temperature nor humidity is controlled for example industrial manufac turing areas The location is usually protected from direct sunshine rain and direct wind e Pollution Degree 4 The pollution generates persistent conductivity caused by conductive dust rain or snow This is typical for outdoor locations TE User Manual 1422 0732 02
20. be Differential probes provide multiple input voltages e Differential mode input voltage Vin Voltage between the positive and negative signal sockets e Positive single ended input voltage Vp Voltage between the positive signal socket and the ground socket e Negative single ended input voltage V Voltage between the negative signal socket and the ground socket e Common mode input voltage Vem Mean voltage of positive and negative signal sockets referred to the ground socket respectively Two of these voltages are independent values the other two can be calculated Vin V V V Va V 2 Typically the differential and the common mode input voltages are used to describe the behavior of a differential probe E User Manual 1422 0732 02 01 23 R amp S RT ZD01 Characteristics of Differential Probes C A EE Common Mode Rejection Ratio CMRR The output voltage Vou which is displayed on the base unit is generally obtained by superimposing the voltages generated from the differential mode input voltage and from the common mode input voltage Vos AV A o Y vdm in vem cm In this equation Ayam is the amplification of the differential mode input voltage and A cm IS the amplification of the common mode input voltage An ideal differential probe is expressed as um 1 and A O In this case the displayed voltage exactly corresponds to the differential input voltage Vin between the two signal sockets
21. by the probe and displayed by the base unit Common mode signals are suppressed by the probe Therefore the user does not initially recognize that the operating voltage window is exceeded owing to inadmissible common mode voltages If unexpected clip ping occurs check the positive or negative input voltage relative to ground 3 3 Maximum Voltage Input The R amp S RT ZD01 high voltage differential probe is rated for CAT Ill environments with a maximum working voltage of 1000 V RMS between each input lead and earth ground Thus it can be used to measure electrical devices or installations of categories O 1 II or III if the effective value of the measured voltage against earth ground does not exceed 1000 V RMS See also chapter 1 2 Measurement Categories on page 5 The rating ensures that the probe is protected against short transient overvoltages as long as the maximum working voltage limit is observed Shock hazard caused by high transient overvoltages Never use the R amp S RT ZD01 probe for measurements in a higher category or at higher effective working voltages Do not use the probe to measure effective working voltages higher than 1000 V RMS between each input lead and earth ground even if the effective differential voltage is lower than 1000 V RMS The maximum working voltage is derated for higher frequencies Refer to the R amp S RT Zxx data sheet for the specification of voltage derating over fre quency aT Use
22. can be short circuited by other conductive materials Cells and batteries must not be removed from their original packaging until they are ready to be used 4 Cells and batteries must not be exposed to any mechanical shocks that are stronger than permitted 5 Ifa cell develops a leak the fluid must not be allowed to come into contact with the skin or eyes If contact occurs wash the affected area with plenty of water and seek medical aid 6 Improperly replacing or charging cells or batteries that contain alkaline electrolytes e g lithium cells can cause explosions Replace cells or batteries only with the matching Rohde amp Schwarz type see parts list in order to ensure the safety of the product 7T Cells and batteries must be recycled and kept separate from residual waste Rechargeable batteries and normal batteries that contain lead mercury or cadmium are hazardous waste Observe the national regulations regarding waste disposal and recycling Transport 1 The product may be very heavy Therefore the product must be handled with care In some cases the user may require a suitable means of lifting or moving the product e g with a lift truck to avoid back or other physical injuries 2 Handles on the products are designed exclusively to enable personnel to transport the product It is therefore not permissible to use handles to fasten the product to or on transport equipment such as cranes fork lifts wagons etc The u
23. ccccnnnnnnnccncnoncnnnnnnnnennnonanannnnnnenenos 8 1 5 1 Inspecting Ihe COMES veian aa 9 1 6 Description of the Probe anxrrrrnnnnnnnnnnnnnnnnnnnnevnnnnnnnnnnnnnnnnnnennnnnnnner 10 1 6 1 Parts of the DEO DG aa GA AA aa 10 1 6 2 Controls and NAG OS usadas 12 1 7 Accessories and ltems rrrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnne 14 2 Putting into OperatioOn rrrnvnnnnnnnvnvnnnnnnnnnnnnnnnnnnnnenennnnnnnnunrr 16 2 1 Connecting the Probe to R amp S Oscilloscopes 16 2 2 Connecting the Probe to the DUT 20 2 2 1 Reducing noise IndbNellOliuosou ui i e alioli 21 2 3 Alternative Battery OperatiON ccccconnnnccococononnceconnanonncrnnnnnannnnennnnnnos 21 3 Characteristics of Differential Probes 23 3 1 Common Mode Rejection Ratio CMRR 24 3 2 Dynamic Range and Operating Voltage Window 25 3 3 Maximum Voltage INput ooooonnccccccconncncnnncccnnnnnnnnnnncnnnennnanannenennnnnnnns 27 4 Maintenance and Service eeeeeeeesess 28 4 1 Service Strategy rrvnnnnnnnnnvnnnnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnnnr 28 4 2 Returning the Probe for Servicing sessessss 28 4 3 Me LS i T HH 29 EI User Manual 1422 0732 02 01 3 4 4
24. d they must be checked on a regular basis to ensure that they are safe to use If there is no power switch for disconnecting the product from the AC supply network or if the power switch is not suitable for this purpose use the plug of the connecting cable to disconnect the product from the AC supply network In such cases always ensure that the power plug is easily reachable and accessible at all times For example if the power plug is the disconnecting device the length of the connecting cable must not exceed 3 m Functional or electronic switches are not suitable for providing disconnection from the AC supply network If products without power switches are integrated into racks or systems the disconnecting device must be provided at the system level 1171 0000 52 06 Page 4 Basic Safety Instructions 5 Never use the product if the power cable is damaged Check the power cables on a regular basis to ensure that they are in proper operating condition By taking appropriate safety measures and carefully laying the power cable ensure that the cable cannot be damaged and that no one can be hurt by for example tripping over the cable or suffering an electric shock 6 The product may be operated only from TN TT supply networks fuse protected with max 16 A higher fuse only after consulting with the Rohde amp Schwarz group of companies 7 Do not insert the plug into sockets that are dusty or dirty Insert the plug firmly and a
25. differential input signal exceeds the dynamic range limit of the probe In this case the signal on the probe output may not accurately represent the signal on the probe input The overrange indicator does not detect overranges of common mode voltages at the probe inputs Power indicator The power indicator lights up continuously if the probe is switched on and powered correctly If the probe is powered by batteries the power indicator blinks if the volt age of the cells is too low eT User Manual 1422 0732 02 01 13 R amp SSRT ZD01 1 7 Accessories and Items Product Description Accessories and Items The following tables show the accessories supplied with the R amp S RT ZD01 high voltage differential probe and the optional service accessories Table 1 1 Accessories supplied Item Quantity Description Sprung hook Maximum rating 1000 V RMS CAT III USB power cord Carrying case with foam inlay 1044 Shock hazard caused by high voltages Always check the working voltage and measurement category of the acces sory If these values are smaller than the values of the R amp S RT ZD01 probe make sure not to exceed the accessory limits User Manual 1422 0732 02 01 14 Accessories and Items Table 1 2 R amp S RT ZD01 service accessories Service Manual The Service Manual contains a detailed description of the performance test for verifying the probe speci fications It is
26. e middle of the display Fig 2 6 Adjusting the offset ee User Manual 1422 0732 02 01 19 R amp S RT ZD01 Putting into Operation Connecting the Probe to the DUT 2 2 Connecting the Probe to the DUT Shock hazard caused by high voltages Before connecting the probe to the test circuit make sure that probe is con nected to the measuring instrument and the instrument is properly grounded Use the auxiliary ground connector if necessary Ensure a stable connection between the output leads and the sprung hooks Switch off the test circuit while connecting and disconnecting the sprung hooks Always use the slider to open the sprung hook The finger guard provides protection Keep your fingers behind the finger guard Connect the sprung hooks to the output leads 2 Using the slider connect the sprung hooks to the circuit Connect the red cable to the more positive voltage level than the black probe cable Slider Finger guard e EN AAA Es gt safe 3 unsafe ka Fig 2 7 Opening the sprung hook Shock hazard caused by high voltages Disconnect the sprung hooks from the DUT before disconnecting the probe from the measuring instrument Keep the probe amplifier box and the output lead away from the circuit being measured EE User Manual 1422 0732 02 01 20 R amp S RT ZD01 Putting into Operation Alternative Battery Operation 2 2 1 Red
27. ebidos 5 En caso de falta de estanqueidad de una celda el l quido vertido no debe entrar en contacto con la piel ni los ojos Si se produce contacto lavar con agua abundante la zona afectada y avisar a un m dico 6 En caso de cambio o recarga inadecuados las celdas o bater as que contienen electrolitos alcalinos p ej las celdas de litio pueden explotar Para garantizar la seguridad del producto las celdas o bater as solo deben ser sustituidas por el tipo Rohde amp Schwarz correspondiente ver lista de recambios 7 Las bater as y celdas deben reciclarse y no deben tirarse a la basura dom stica Las bater as o acumuladores que contienen plomo mercurio o cadmio deben tratarse como residuos especiales Respete en esta relaci n las normas nacionales de eliminaci n y reciclaje Transporte 1 El producto puede tener un peso elevado Por eso es necesario desplazarlo o transportarlo con precauci n y si es necesario usando un sistema de elevaci n adecuado p ej una carretilla elevadora a fin de evitar lesiones en la espalda u otros da os personales 2 Las asas instaladas en los productos sirven solamente de ayuda para el transporte del producto por personas Por eso no est permitido utilizar las asas para la sujeci n en o sobre medios de transporte como p ej gr as carretillas elevadoras de horquilla carros etc Es responsabilidad suya fijar los productos de manera segura a los medios de transporte o elevaci n
28. egun las normas de seguridad vigentes Nuestro sistema de garantia de calidad controla constantemente que sean cumplidas estas normas El presente producto ha sido fabricado y examinado seg n el certificado de conformidad adjunto de la UE y ha salido de nuestra planta en estado impecable seg n los est ndares t cnicos de seguridad Para poder preservar este estado y garantizar un funcionamiento libre de peligros el usuario deber atenerse a todas las indicaciones informaciones de seguridad y notas de alerta El grupo de empresas Rohde amp Schwarz est siempre a su disposici n en caso de que tengan preguntas referentes a estas informaciones de seguridad Adem s queda en la responsabilidad del usuario utilizar el producto en la forma debida Este producto est destinado exclusivamente al uso en la industria y el laboratorio o si ha sido expresamente autorizado para aplicaciones de campo y de ninguna manera deber ser utilizado de modo que alguna persona cosa pueda sufrir da o El uso del producto fuera de sus fines definidos o sin tener en cuenta las instrucciones del fabricante queda en la responsabilidad del usuario El fabricante no se hace en ninguna forma responsable de consecuencias a causa del mal uso del producto Se parte del uso correcto del producto para los fines definidos si el producto es utilizado conforme a las indicaciones de la correspondiente documentaci n del producto y dentro del margen de rendimiento definido ver h
29. ene 13 Probe Calibration eene 29 Cleaning T 29 Control box ceeeemm 12 Returning poo sl 28 S ey AVA or gt AE GAEL Nai 28 Signal clipping ccccccccconnocccccccnnncnccnnnno 25 User Manual 1422 0732 02 01 32
30. enuation ratio on the probe to 100 1 2 Connect the R amp S RT ZD01 probe to an R amp S oscilloscope as described in chap ter 2 1 Connecting the Probe to R amp S Oscilloscopes on page 16 3 Connect the red sprung hook to the square wave output IL of the oscilloscope 4 Connect the black sprung hook to the probe ground connector L of the oscil loscope 5 Press the AUTOSET key on the oscilloscope A square wave with 1 V pp between 0 V and 1 V is displayed on the display 9g A User Manual 1422 0732 02 01 31 R amp S9RT ZD01 Index A Single ended input voltage 23 Attenuation ratio seeeessse 13 U B Unpacking aNG mann 8 Batteries aaa 21 SP power CONT sia 13 C Cleaning 29 Clipping AA 25 CMRR 11 meme ene rentrer rere 24 Common mode input voltage 23 Common mode range 25 Common Mode Rejection Ratio 24 Connecting Instrument cse 16 D Differential input voltage 23 25 Dynamic range ula 25 l Input voltages csi 23 M Maintenance rrarnnnnrnnnnnnnnnnnnnrnnnvnnvenernen 28 O Operating voltage window 25 Oscilloscope Connecting esses 16 Overrange indicator 13 P I T Lur 10 Power indicator eese 13 Power input 13 21 Power switch e
31. he probe EIM User Manual 1422 0732 02 01 16 R amp S RT ZD01 Putting into Operation Connecting the Probe to R amp S Oscilloscopes Fig 2 1 Connecting the BNC output connector and the auxiliary ground connector when using a measurement instrument without grounded inputs 3 Connect the USB power cord to the power input of the probe and to a free USB port of the oscilloscope You can also use a USB hub Alternatively the probe can be powered with batteries see chapter 2 3 Alter native Battery Operation on page 21 eoe 1805 Fig 2 2 Connecting the probe to the R amp S oscilloscope AAA cc V cqctvcc vvvvve ceeeegr CJZ j5ZJ5 8 966i 58T 8 686 User Manual 1422 0732 02 01 17 R amp S RT ZD01 Putting into Operation Connecting the Probe to R amp S Oscilloscopes 4 Switch the power switch of the probe to ON 5 Adjust the attenuation ratio on the probe If you measure signals below 140 V peak set the attenuation to 100 1 to get higher resolution and less noise Otherwise set the attenuation to 1000 1 6 If you use an R amp S RTO set up the oscilloscope as follows a On the Vertical menu select Probe Setup E gt Auto zero y ES Channel Channels Setup Use AutoZero Power Calcula
32. i n en la secci n Funcionamiento punto 7 Palabras de se al y su significado En la documentaci n del producto se utilizan las siguientes palabras de se al con el fin de advertir contra riesgos y peligros PELIGRO identifica un peligro inminente con riesgo elevado que provocar muerte o lesiones graves si no se evita ADVERTENCIA identifica un posible peligro con riesgo medio de provocar muerte o lesiones graves si no se evita 4 PELIGRO ATENCI N identifica un peligro con riesgo reducido de provocar lesiones leves o moderadas si no se evita AVISO indica la posibilidad de utilizar mal el producto y como consecuencia da arlo En la documentaci n del producto se emplea de forma sin nima el t rmino CUIDADO Las palabras de se al corresponden a la definici n habitual para aplicaciones civiles en el rea econ mica europea Pueden existir definiciones diferentes a esta definici n en otras reas econ micas o en aplicaciones militares Por eso se deber tener en cuenta que las palabras de se al aqu descritas sean utilizadas siempre solamente en combinaci n con la correspondiente documentaci n del producto y solamente en combinaci n con el producto correspondiente La utilizaci n de las palabras de se al en combinaci n con productos o documentaciones que no les correspondan puede llevar a interpretaciones equivocadas y tener por consecuencia da os en personas u objetos 1171 0000 52
33. igned built and tested in accordance with the attached EC Certificate of Conformity and has left the manufacturer s plant in a condition fully complying with safety standards To maintain this condition and to ensure safe operation you must observe all instructions and warnings provided in this manual If you have any questions regarding these safety instructions the Rohde amp Schwarz group of companies will be happy to answer them Furthermore it is your responsibility to use the product in an appropriate manner This product is designed for use solely in industrial and laboratory environments or if expressly permitted also in the field and must not be used in any way that may cause personal injury or property damage You are responsible if the product is used for any purpose other than its designated purpose or in disregard of the manufacturer s instructions The manufacturer shall assume no responsibility for such use of the product The product is used for its designated purpose if it is used in accordance with its product documentation and within its performance limits see data sheet documentation the following safety instructions Using the product requires technical skills and in some cases a basic knowledge of English It is therefore essential that only skilled and specialized staff or thoroughly trained personnel with the required skills be allowed to use the product If personal safety gear is required for using Rohde amp Schw
34. interrupci n puede tener como consecuencia el riesgo de que el producto sea fuente de choques el ctricos Si se utilizan cables alargadores o regletas de enchufe deber garantizarse la realizaci n de un examen regular de los mismos en cuanto a su estado t cnico de seguridad Si el producto no est equipado con un interruptor para desconectarlo de la red o bien si el interruptor existente no resulta apropiado para la desconexi n de la red el enchufe del cable de conexi n se deber considerar como un dispositivo de desconexi n El dispositivo de desconexi n se debe poder alcanzar f cilmente y debe estar siempre bien accesible Si p ej el enchufe de conexi n a la red es el dispositivo de desconexi n la longitud del cable de conexi n no debe superar 3 m Los interruptores selectores o electr nicos no son aptos para el corte de la red el ctrica Si se integran productos sin interruptor en bastidores o instalaciones se deber colocar el interruptor en el nivel de la instalaci n No utilice nunca el producto si est da ado el cable de conexi n a red Compruebe regularmente el correcto estado de los cables de conexi n a red Aseg rese mediante las medidas de protecci n y de instalaci n adecuadas de que el cable de conexi n a red no pueda ser da ado o de que nadie pueda ser dafiado por l p ej al tropezar o por un choque el ctrico Solamente est permitido el funcionamiento en redes de alimentaci n TN TT a
35. king distance to the base unit The output lead is specially qualified for high voltage usage Input leads Provide flexible contact to the DUT even in confined physical conditions The input leads are each 30 cm long thus the maximum distance of the measurement points is 60 cm The 4 mm safety banana plugs can be used to contact the DUT directly or to connect suitable contact accessories like the sprung hooks delivered with the probe See also chapter 2 2 Connecting the Probe to the DUT on page 20 Shock hazard caused by high voltages The input leads have a jacket wear indicator If the input lead s jacket is excessively worn a different jacket color becomes visible If you see this color indicator do not use the probe NTZS User Manual 1422 0732 02 01 11 R amp S RT ZD01 Product Description Description of the Probe 1 6 2 Controls and Indicators MAX DIFFERENTIAL INPUT 1400 V PEAK 1000 1 140 V PEAK 100 1 MAX INPUT EACH PIN TO GROUND 1400 V PEAK OPERATING WINDOW 1000 V RMS N cam A t Ll Lo DE amp SCHWARZ RT 2D01 HIGH VOLTAGE DIFFERENTIAL PROBE 35ns 100 MHz sko 35pF 100 1 I 1000 1 ATTENUATION RATIO H CONNECT TO GROUNDED INSTRUMENT ONLY USE 1 MQ INPUT COUPLING Fig 1 4 Probe control box 1 Attenuation ratio switch 2 Power input 3 Power switch 4 Offset adjustment 5 O
36. ll the way into the socket provided for this purpose Otherwise sparks that result in fire and or injuries may occur 8 Do not overload any sockets extension cords or connector strips doing so can cause fire or electric shocks 9 For measurements in circuits with voltages Vims gt 30 V suitable measures e g appropriate measuring equipment fuse protection current limiting electrical separation insulation should be taken to avoid any hazards 10 Ensure that the connections with information technology equipment e g PCs or other industrial computers comply with the IEC60950 1 EN60950 1 or 1EC61010 1 EN 61010 1 standards that apply in each case 11 Unless expressly permitted never remove the cover or any part of the housing while the product is in operation Doing so will expose circuits and components and can lead to injuries fire or damage to the product 12 1f a product is to be permanently installed the connection between the protective conductor terminal on site and the product s protective conductor must be made first before any other connection is made The product may be installed and connected only by a licensed electrician 13 For permanently installed equipment without built in fuses circuit breakers or similar protective devices the supply circuit must be fuse protected in such a way that anyone who has access to the product as well as the product itself is adequately protected from injury or damage 14 Use sui
37. low the manufacturer s installation instructions when installing the product and fastening it to objects or structures e g walls and shelves An installation that is not carried out as described in the product documentation could result in personal injury or even death Do not place the product on heat generating devices such as radiators or fan heaters The ambient temperature must not exceed the maximum temperature specified in the product documentation or in the data sheet Product overheating can cause electric shock fire and or serious personal injury or even death Electrical safety If the information on electrical safety is not observed either at all or to the extent necessary electric shock fire and or serious personal injury or death may occur 1 Prior to switching on the product always ensure that the nominal voltage setting on the product matches the nominal voltage of the AC supply network If a different voltage is to be set the power fuse of the product may have to be changed accordingly In the case of products of safety class with movable power cord and connector operation is permitted only on sockets with a protective conductor contact and protective conductor Intentionally breaking the protective conductor either in the feed line or in the product itself is not permitted Doing so can result in the danger of an electric shock from the product If extension cords or connector strips are implemente
38. ltage window and attenuation ratio are shown in figure 3 2 The dynamic range between the positive and negative signal pins depends on the selected attenuation but the operating voltage window between each of the signal pins and common ground is not affected by the attenu ation The figure 3 3 shows several examples for permissible and impermissible inputs 1000 1 setting Operating voltage window 1400 V Input voltage Time Voltage to gnd at pos signal input Vp Voltage to gnd at neg signal input Vn 1400 V Operating voltage window Fig 3 3 Signal curves a Two signals of 700 V and opposing phase are applied to positive and negative inputs At the peaks the probe is driven with an input voltage of 1400 V between the positive and negative signal pin The dynamic range limit is reached b The negative signal pin is connected to ground the positive pin is driven with an input voltage of 1400 V Dynamic range and operating voltage window are used completely Note that the oscilloscope displays the same waveform as with example a c Dynamic range limit is exceeded The oscilloscope displays a clipped signal d Operating voltage window is exceeded The oscilloscope displays a clipped signal Te User Manual 1422 0732 02 01 26 R amp S9RT ZD01 Characteristics of Differential Probes Hacc ee A EEE EE d Maximum Voltage Input Signal clipping Only differential input signals are detected
39. medio ambiente dir jase a su servicio de atenci n al cliente de Rohde amp Schwarz Si se trabaja de manera mec nica y o t rmica cualquier producto o componente m s all del funcionamiento previsto pueden liberarse sustancias peligrosas polvos con contenido de metales pesados como p ej plomo berilio o n quel Por eso el producto solo debe ser desmontado por personal especializado con formaci n adecuada Un desmontaje inadecuado puede ocasionar da os para la salud Se deben tener en cuenta las directivas nacionales referentes a la eliminaci n de residuos En caso de que durante el trato del producto se formen sustancias peligrosas o combustibles que deban tratarse como residuos especiales p ej refrigerantes o aceites de motor con intervalos de cambio definidos deben tenerse en cuenta las indicaciones de seguridad del fabricante de dichas sustancias y las normas regionales de eliminaci n de residuos Tenga en cuenta tambi n en caso necesario las indicaciones de seguridad especiales contenidas en la documentaci n del producto La eliminaci n incorrecta de sustancias peligrosas o combustibles puede causar da os a la salud o da os al medio ambiente Se puede encontrar m s informaci n sobre la protecci n del medio ambiente en la p gina web de Rohde amp Schwarz 1171 0000 52 06 Page 19 Customer Support Technical support where and when you need it For quick expert help with any Rohde amp Schwarz equipment
40. nd accumulators mug i I For additional information see section Waste disposal Environmental protection item 1 Be careful when handling electrostatic sensitive devices EU labeling for separate collection of electrical and electronic devices For additonal information see section Waste disposal Environmental protection item 2 i He ie d Warning Laser radiation gt gt For additional information see section Operation item 7 1171 0000 52 06 Page 2 Basic Safety Instructions Signal words and their meaning The following signal words are used in the product documentation in order to warn the reader about risks and dangers A DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury A WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury A CAUTION Indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates the possibility of incorrect operation which can result in damage to the product In the product documentation the word ATTENTION is used synonymously These signal words are in accordance with the standard definition for civil applications in the European Economic Area Definitions that deviate from the standard definition may also exist in other economic areas or military
41. ns who use the products are physically mentally and emotionally fit enough to do so otherwise injuries or material damage may occur It is the responsibility of the employer operator to select suitable personnel for operating the products 2 Before you move or transport the product read and observe the section titled Transport 3 As with all industrially manufactured goods the use of substances that induce an allergic reaction allergens such as nickel cannot be generally excluded If you develop an allergic reaction such as a skin rash frequent sneezing red eyes or respiratory difficulties when using a Rohde amp Schwarz product consult a physician immediately to determine the cause and to prevent health problems or stress 4 Before you start processing the product mechanically and or thermally or before you take it apart be sure to read and pay special attention to the section titled Waste disposal Environmental protection item 1 5 Depending on the function certain products such as RF radio equipment can produce an elevated level of electromagnetic radiation Considering that unborn babies require increased protection pregnant women must be protected by appropriate measures Persons with pacemakers may also be exposed to risks from electromagnetic radiation The employer operator must evaluate workplaces where there is a special risk of exposure to radiation and if necessary take measures to avert the potential danger
42. nuos enrojecimiento de la conjuntiva o dificultades respiratorias debe avisarse inmediatamente a un m dico para investigar las causas y evitar cualquier molestia o da o a la salud Antes de la manipulaci n mec nica y o t rmica o el desmontaje del producto debe tenerse en cuenta imprescindiblemente el cap tulo Eliminaci n protecci n del medio ambiente punto 1 Ciertos productos como p ej las instalaciones de radiocomunicaci n RF pueden a causa de su funci n natural emitir una radiaci n electromagn tica aumentada Deben tomarse todas las medidas necesarias para la protecci n de las mujeres embarazadas Tambi n las personas con marcapasos pueden correr peligro a causa de la radiaci n electromagn tica El empresario operador tiene la obligaci n de evaluar y se alizar las reas de trabajo en las que exista un riesgo elevado de exposici n a radiaciones Tenga en cuenta que en caso de incendio pueden desprenderse del producto sustancias t xicas gases l quidos etc que pueden generar da os a la salud Por eso en caso de incendio deben usarse medidas adecuadas como p ej m scaras antig s e indumentaria de protecci n 1171 0000 52 06 Page 16 Instrucciones de seguridad elementales Los productos con laser estan provistos de indicaciones de advertencia normalizadas en funci n de la clase de laser del que se trate Los rayos l ser pueden provocar da os de tipo biol gico a causa de las propiedades de
43. oja de datos documentaci n informaciones de seguridad que siguen El uso del producto hace necesarios conocimientos t cnicos y ciertos conocimientos del idioma ingl s Por eso se debe tener en cuenta que el producto solo pueda ser operado por personal especializado o personas instruidas en profundidad con las capacidades correspondientes Si fuera necesaria indumentaria de seguridad para el uso de productos de Rohde amp Schwarz encontrar a la informaci n debida en la documentaci n del producto en el cap tulo correspondiente Guarde bien las informaciones de seguridad elementales as como la documentaci n del producto y entr guelas a usuarios posteriores 1171 0000 52 06 Page 10 Instrucciones de seguridad elementales Tener en cuenta las informaciones de seguridad sirve para evitar en lo posible lesiones o da os por peligros de toda clase Por eso es imprescindible leer detalladamente y comprender por completo las siguientes informaciones de seguridad antes de usar el producto y respetarlas durante el uso del producto Deber n tenerse en cuenta todas las dem s informaciones de seguridad como p ej las referentes a la protecci n de personas que encontrar n en el cap tulo correspondiente de la documentaci n del producto y que tambi n son de obligado cumplimiento En las presentes informaciones de seguridad se recogen todos los objetos que distribuye el grupo de empresas Rohde amp Schwarz bajo la denominaci n de produc
44. ow Two separate specifications are necessary in order to characterize the permissible input voltage range of a differential voltage probe e The dynamic range or differential mode range designates the maximum dif ferential voltage Vin that may occur between the positive and negative signal pin e At the same time the two voltage values at each of the two signal pins V und V referenced to the common ground must not exceed a specific limit value This limitation is referred to as the operating voltage window Some manufacturers also use the less precise term common mode range for the same parameter If one of these ranges is exceeded an unwanted signal clipping may occur 1000 1 setting 100 1 setting Operating voltage window 1400 V i Vin 140 V Vin 140 V d a 8 Dynamic range Dynamic range o x limit limit id gt gt 2 o LY a e e E T IL E Vem Vem OV gt gt Time gnd Dynamic range Dynamic range limit limit Voltage to gnd at pos signal input Vp Voltage to gnd at neg signal input Vn 1400 V Operating voltage window Fig 3 2 Dynamic range and operating voltage window for both attenuation ratios 100 1 and 1000 1 A EUM TE M E C T CP T Mn c User Manual 1422 0732 02 01 25 R amp S RT ZD01 Characteristics of Differential Probes FP REE A A A Dynamic Range and Operating Voltage Window The dependencies of dynamic range operating vo
45. r Manual 1422 0732 02 01 27 R amp S RT ZD01 Maintenance and Service Service Strategy 4 Maintenance and Service 4 1 Service Strategy The R amp S RT ZD01 high voltage differential probe is a high precision high perform ance instrument that extends the limits of today s technological possibilities Like all Rohde amp Schwarz instruments the R amp S RT ZD01 high voltage differential probe is of high quality and requires only minimum service and repair However if the probe needs to be serviced contact your Rohde amp Schwarz service center Return a defective probe to the Rohde amp Schwarz service center for diagnosis and exchange You can return the R amp S RT ZD01 high voltage differential probe for calibration The service personnel will then perform the required tests 4 2 Returning the Probe for Servicing Use the original packaging to return the R amp S RT ZD01 high voltage differential probe to your Rohde amp Schwarz service center If you cannot use the original packaging consider the following 1 Use a sufficiently sized box 2 Protect the probe from damage and moisture e g with bubble wrap 3 Use some kind of protective material e g crumpled newspaper to stabilize the probe inside the box 4 Seal the box with tape 5 Address the package to your nearest Rohde amp Schwarz service center AAA User Manual 1422 0732 02 01 28 R amp S RT ZD01 Maintenance and Service
46. seguradas con fusibles de 16 A como m ximo utilizaci n de fusibles de mayor amperaje solo previa consulta con el grupo de empresas Rohde amp Schwarz Nunca conecte el enchufe en tomas de corriente sucias o llenas de polvo Introduzca el enchufe por completo y fuertemente en la toma de corriente La no observaci n de estas medidas puede provocar chispas fuego y o lesiones No sobrecargue las tomas de corriente los cables alargadores o las regletas de enchufe ya que esto podr a causar fuego o choques el ctricos En las mediciones en circuitos de corriente con una tensi n Uef gt 30 V se deber n tomar las medidas apropiadas para impedir cualquier peligro p ej medios de medici n adecuados seguros limitaci n de tensi n corte protector aislamiento etc 1171 0000 52 06 Page 14 Instrucciones de seguridad elementales 10 Para la conexi n con dispositivos inform ticos como un PC o un ordenador industrial debe comprobarse que stos cumplan los est ndares IEC60950 1 EN60950 1 o IEC61010 1 EN 61010 1 v lidos en cada caso 11 A menos que est permitido expresamente no retire nunca la tapa ni componentes de la carcasa mientras el producto est en servicio Esto pone a descubierto los cables y componentes el ctricos y puede causar lesiones fuego o da os en el producto 12 Si un producto se instala en un lugar fijo se deber primero conectar el conductor de protecci n fijo con el conductor de protecci n del prod
47. ser is responsible for securely fastening the products to or on the means of transport or lifting Observe the safety regulations of the manufacturer of the means of transport or lifting Noncompliance can result in personal injury or material damage 1171 0000 52 06 Page 8 Basic Safety Instructions If you use the product in a vehicle it is the sole responsibility of the driver to drive the vehicle safely and properly The manufacturer assumes no responsibility for accidents or collisions Never use the product in a moving vehicle if doing so could distract the driver of the vehicle Adequately secure the product in the vehicle to prevent injuries or other damage in the event of an accident Waste disposal Environmental protection 1 Specially marked equipment has a battery or accumulator that must not be disposed of with unsorted municipal waste but must be collected separately It may only be disposed of at a suitable collection point or via a Rohde amp Schwarz customer service center Waste electrical and electronic equipment must not be disposed of with unsorted municipal waste but must be collected separately Rohde amp Schwarz GmbH amp Co KG has developed a disposal concept and takes full responsibility for take back obligations and disposal obligations for manufacturers within the EU Contact your Rohde amp Schwarz customer service center for environmentally responsible disposal of the product If produc
48. su radiaci n y debido a su concentraci n extrema de potencia electromagn tica En caso de que un producto Rohde amp Schwarz contenga un producto l ser p ej un lector de CD DVD no debe usarse ninguna otra configuraci n o funci n aparte de las descritas en la documentaci n del producto a fin de evitar lesiones p ej debidas a irradiaci n l ser Clases CEM seg n CISPR 11 Clase A dispositivo apropiado para el uso en cualquier zona excepto en reas residenciales y en aquellas zonas que se encuentran conectadas a una red de suministro de baja tensi n que alimenta un edificio de viviendas Clase B dispositivo apropiado para el uso en reas residenciales y en aquellas zonas que se encuentran conectadas a una red de suministro de baja tensi n que alimenta un edificio de viviendas Reparaci n y mantenimiento 1 El producto solamente debe ser abierto por personal especializado con autorizaci n para ello Antes de manipular el producto o abrirlo es obligatorio desconectarlo de la tensi n de alimentaci n para evitar toda posibilidad de choque el ctrico El ajuste el cambio de partes el mantenimiento y la reparaci n deber n ser efectuadas solamente por electricistas autorizados por Rohde amp Schwarz Si se reponen partes con importancia para los aspectos de seguridad p ej el enchufe los transformadores o los fusibles solamente podr n ser sustituidos por partes originales Despu s de cada cambio de p
49. table overvoltage protection to ensure that no overvoltage such as that caused by a bolt of lightning can reach the product Otherwise the person operating the product will be exposed to the danger of an electric shock 15 Any object that is not designed to be placed in the openings of the housing must not be used for this purpose Doing so can cause short circuits inside the product and or electric shocks fire or injuries 1171 0000 52 06 Page 5 Basic Safety Instructions 16 Unless specified otherwise products are not liquid proof see also section Operating states and operating positions item 1 Therefore the equipment must be protected against penetration by liquids If the necessary precautions are not taken the user may suffer electric shock or the product itself may be damaged which can also lead to personal injury 17 Never use the product under conditions in which condensation has formed or can form in or on the product e g if the product has been moved from a cold to a warm environment Penetration by water increases the risk of electric shock 18 Prior to cleaning the product disconnect it completely from the power supply e g AC supply network or battery Use a soft non linting cloth to clean the product Never use chemical cleaning agents such as alcohol acetone or diluents for cellulose lacquers Operation 1 Operating the products requires special training and intense concentration Make sure that perso
50. tion Probe Setu Input impedance Bandwidth Set offset to mean TITE Probe Maintenance gt Digital Filter File Edit Horizontal Trigger Vertical Math Cursor Meas Masks Search Protocol Display Fig 2 3 Access to Probe Setup b Under Probe detection select the Manual tab Select the Predefined probe RT ZD01 100 1 or RT ZD01 1000 1 according to the setting on the probe 7 f you use an R amp S RTM set up the oscilloscope as follows a Inthe VERTICAL section on the front panel press the appropriate channel key b On the first page of the Channels menu set e Coupling DC e Termination 1 MQ e Press More Coupling Termination Bandwidth Offset Inet scale Scale Im nnn More 112 ca gt JE o Fig 2 4 RTM Channel1 menu 1st page c Press Probe on the second page of the Channels menu User Manual 1422 0732 02 01 18 R amp S RT ZD01 Putting into Operation Connecting the Probe to R amp S Oscilloscopes d In the Probe menu set e Unit V Volt e Attenuation x100 or x1000 according to the setting on the probe Fig 2 5 RTM Channel1 Probe menu attenuation 100 1 8 Adjust the offset level a Set the measuring instrument to the smallest vertical resolution vertical scale b Short the two input leads of the probe c Using a small screwdriver turn the Offset Adjust screw until the waveform meets exactly the 0 V position in th
51. to entre ellos tambi n aparatos instalaciones as como toda clase de accesorios Los datos espec ficos del producto figuran en la hoja de datos y en la documentaci n del producto S mbolos y definiciones de seguridad S mbolo Significado S mbolo Significado Aviso punto de peligro general Tensi n de alimentaci n de P PUESTA EN MARCHA PARADA Observar la documentaci n del producto Atenci n en el manejo de D Indicaci n de estado de espera dispositivos de peso elevado standby in Peligro de choque el ctrico Corriente continua DC AN Advertencia superficie caliente NI Corriente alterna AC Conexi n a conductor de Corriente continua Corriente protecci n alterna DC AC Conexi n a tierra lal El aparato est protegido en su L totalidad por un aislamiento doble reforzado Conexi n a masa Distintivo de la UE para bater as y acumuladores M s informaci n en la secci n Eliminaci n protecci n del medio ambiente punto 1 1171 0000 52 06 Page 11 Instrucciones de seguridad elementales Simbolo Significado Simbolo Significado Aviso Cuidado en el manejo de Distintivo de la UE para la dispositivos sensibles a la eliminaci n por separado de electrost tica ESD dispositivos el ctricos y electr nicos M s informaci n en la secci n Eliminaci n protecci n del medio ambiente punto 2 Advertencia rayo l ser M s informac
52. to the risk of an electric shock Adjustments replacement of parts maintenance and repair may be performed only by electrical experts authorized by Rohde amp Schwarz Only original parts may be used for replacing parts relevant to safety e g power switches power transformers fuses A safety test must always be performed after parts relevant to safety have been replaced visual inspection protective conductor test insulation resistance measurement leakage current measurement functional test This helps ensure the continued safety of the product Batteries and rechargeable batteries cells If the information regarding batteries and rechargeable batteries cells is not observed either at all or to the extent necessary product users may be exposed to the risk of explosions fire and or serious personal injury and in some cases death Batteries and rechargeable batteries with alkaline electrolytes e g lithium cells must be handled in accordance with the EN 62133 standard 1171 0000 52 06 Page 7 Basic Safety Instructions 1 Cells must not be taken apart or crushed 2 Cells or batteries must not be exposed to heat or fire Storage in direct sunlight must be avoided Keep cells and batteries clean and dry Clean soiled connectors using a dry clean cloth 3 Cells or batteries must not be short circuited Cells or batteries must not be stored in a box or in a drawer where they can short circuit each other or where they
53. ts or their components are mechanically and or thermally processed in a manner that goes beyond their intended use hazardous substances heavy metal dust such as lead beryllium nickel may be released For this reason the product may only be disassembled by specially trained personnel Improper disassembly may be hazardous to your health National waste disposal regulations must be observed If handling the product releases hazardous substances or fuels that must be disposed of in a special way e g coolants or engine oils that must be replenished regularly the safety instructions of the manufacturer of the hazardous substances or fuels and the applicable regional waste disposal regulations must be observed Also observe the relevant safety instructions in the product documentation The improper disposal of hazardous substances or fuels can cause health problems and lead to environmental damage For additional information about environmental protection visit the Rohde amp Schwarz website 1171 0000 52 06 Page 9 Instrucciones de seguridad elementales jEs imprescindible leer y cumplir las siguientes instrucciones e informaciones de seguridad El principio del grupo de empresas Rohde amp Schwarz consiste en tener nuestros productos siempre al dia con los estandares de seguridad y de ofrecer a nuestros clientes el maximo grado de seguridad Nuestros productos y todos los equipos adicionales son siempre fabricados y examinados s
54. ucing noise induction Twist the input leads to cancel noise that is induced into the input leads Input leads that form a large loop area pick up any radiated electromagnetic field that passes through the loop The fields induce noise in the input leads that appears as a differential mode signal Twisting the leads minimizes the loop area Fig 2 8 Leads untwisted P it al dg t gt E n bg mo verlas sarao 01152000 N Fig 2 9 Leads twisted 2 3 Alternative Battery Operation Usually the probe is powered by the USB power cord that is connected to a USB connector of the oscilloscope See also Power input on page 13 Alternatively you can use four AA batteries TE User Manual 1422 0732 02 01 21 Alternative Battery Operation Fig 2 10 Inserting batteries Note Batteries are not included in the delivery of the probe you have to purchase them separately If the voltage of the cells is too low the power indicator on the probe control box blinks R amp S9RT ZD01 Characteristics of Differential Probes eee AAA A dee el 3 Characteristics of Differential Probes A differential probe has three sockets the positive signal socket the negative signal socket and the ground socket Fig 3 1 Input voltages on a differential pro
55. ucto antes de hacer cualquier otra conexi n La instalaci n y la conexi n deber n ser efectuadas por un electricista especializado 13 En el caso de dispositivos fijos que no est n provistos de fusibles interruptor autom tico ni otros mecanismos de seguridad similares el circuito de alimentaci n debe estar protegido de modo que todas las personas que puedan acceder al producto as como el producto mismo est n a salvo de posibles da os 14 Todo producto debe estar protegido contra sobretensi n debida p ej a una ca da del rayo mediante los correspondientes sistemas de protecci n Si no el personal que lo utilice quedar expuesto al peligro de choque el ctrico 15 No debe introducirse en los orificios de la caja del aparato ning n objeto que no est destinado a ello Esto puede producir cortocircuitos en el producto y o puede causar choques el ctricos fuego o lesiones 16 Salvo indicaci n contraria los productos no est n impermeabilizados ver tambi n el cap tulo Estados operativos y posiciones de funcionamiento punto 1 Por eso es necesario tomar las medidas necesarias para evitar la entrada de l quidos En caso contrario existe peligro de choque el ctrico para el usuario o de da os en el producto que tambi n pueden redundar en peligro para las personas 17 No utilice el producto en condiciones en las que pueda producirse o ya se hayan producido condensaciones sobre el producto o en el interior de ste
56. verrange indicator 6 Power indicator aT ees User Manual 1422 0732 02 01 12 R amp S RT ZD01 Product Description Description of the Probe Attenuation ratio switch Sets the attenuation of the probe to 100 1 or 1000 1 The setting 1000 1 provides a maximum voltage range of up to 1 4 kV peak The setting 100 1 works with measurement voltages up to 140 V peak and is characterized by less noise The selected attenuation does not influence the allowed working voltage measure ment category and the usable common mode range Thus setting the attenuation does neither cause a hazardous situation nor a measurement error due to inad missible common mode voltages Power input The supplied voltage must be less than 12 V and greater than 4 4 V otherwise the probe could be damaged or cannot be operated properly Use the USB power cord to connect the probe to an unused USB port of the oscilloscope or another USB device e g USB hub Alternatively batteries can be used to power the probe Power switch Switches the probe on or off If you use batteries make sure to switch the probe off after use to extend the lifetime of the batteries Offset adjustment The rotary knob removes unwanted offset voltages of the probe or the measurement object from the measurement signal See also chapter 2 1 Connecting the Probe to R amp S Oscilloscopes on page 16 Overrange indicator The overrange indicator lights red if the voltage of the