Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide

image

Contents

1. Everything to the right of the trigger point is called post trigger information The amount of delay range pre trigger and post trigger information available depends on the time div selected and memory depth The horizontal position knob works in the Normal time mode while acquisitions are running or when they are stopped When running adjusting the horizontal scale knob changes the sample rate When stopped adjusting the horizontal scale knob lets you zoom into acquired data See Panning and Zooming Single or Stopped Acquisitions on page 46 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 45 2 Horizontal Controls Note that the horizontal position knob has a different purpose in the Zoom display See To display the zoomed time base on page 50 Panning and Zooming Single or Stopped Acquisitions When the oscilloscope is stopped use the horizontal scale and position knobs to pan and zoom your waveform The stopped display may contain several acquisitions worth of information but only the last acquisition is available for pan and zoom The ability to pan move horizontally and scale expand or compress horizontally an acquired waveform is important because of the additional insight it can reveal about the captured waveform This additional insight is often gained from seeing the waveform at different levels of abstraction You may want to view both the big picture and the specific little picture de
2. Automotive serial decode and trigger UART RS232 serial decode and trigger Segmented Memory Mask limit testing 200MHz 100MHz Bandwidth Education kitticense WaveGen license Remote Log Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 273 21 Web Interface Setting a Password 274 Whenever you connect the oscilloscope to a LAN it is good practice to set a password The password prevents someone from remotely accessing the oscilloscope via a Web browser and changing parameters Remote users can still view the Welcome screen view network status etc but they can t operate the instrument or change its setup without the password To set a password 1 Access the oscilloscope s web interface see Accessing the Web Interface on page 262 2 When the oscilloscope s web interface is displayed select the Configure Network tab from the instrument s Welcome page 3 Click the Modify Configuration button Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Web Interface 21 KEYSIGHT TECHNOLOGIES ical vy Current Network Configuration Modify Configuration Parameter Currently in use toma on on Configure on Network Agilent MSOX2024A InfiniiVision US50210029 tab E ra 156 140 24 15 156 140 24 47 aaa of 7 on on Keysight InfiniiVision 2000 X Series Oscilloscopes
3. 278 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Reference 22 CAUTION A Maximum input voltage at digital channels 40 V peak CAT transient overvoltage 800 Vpk Environmental Conditions Environment Indoor use only Ambient temperature Operating 0 C to 55 C non operating 40 C to 71 C Humidity Operating Up to 80 RH at or below 40 C Up to 45 RH up to 50 C Non operating Up to 95 RH up to 40 C Up to 45 RH up to 50 C Altitude Operating and non operating to 4 000 m 13 123 ft Overvoltage Category This product is intended to be powered by MAINS that comply to Overvoltage Category Il which is typical of cord and plug connected equipment Pollution Degree The InfiniiVision 2000 3000 X Series oscilloscopes may be operated in environments of Pollution Degree 2 or Pollution Degree 1 Pollution Degree Definitions Pollution Degree 1 No pollution or only dry non conductive pollution occurs The pollution has no influence Example A clean room or climate controlled office environment Pollution Degree 2 Normally only dry non conductive pollution occurs Occasionally a temporary conductivity caused by condensation may occur Example General indoor environment Pollution Degree 3 Conductive pollution occurs or dry non conductive pollution occurs which becomes conductive due to condensation which is expected Example Shelter
4. The output frequency shifts between the original carrier frequency and this hop frequency 3 Press the FSK Rate softkey and turn the Entry knob to specify the rate at which the output frequency shifts The FSK rate specifies a digital square wave modulating signal The following screen shows an FSK modulation of a 100 kHz sine wave carrier signal 50 005 Channels Naveform Generator Modulation Menu Modulation FSK Rate SK 10kH2 To restore waveform generator defaults 1 Ifthe Waveform Generator Menu is not currently displayed on the oscilloscope s softkeys press the Wave Gen key 2 In the Waveform Generator Menu press the Settings softkey 220 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Waveform Generator 17 3 In the Waveform Generator Settings Menu press the Default Wave Gen softkey The waveform generator factory default settings 1 kHz sine wave 500 mVpp O V offset High Z output load are restored Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 221 17 Waveform Generator 222 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data Saving Setups Screen Images or Data 223 Recalling Setups Masks or Reference Waveforms 231 Recalling Default Setups 232 Performing a Secure Erase 233 Oscilloscope setups reference waveforms and mas
5. Channel sensitivity trigger level measurement results and math functions will reflect the measurement units you have selected To specify the probe attenuation The probe attenuation factor must be set properly for accurate measurement results To set the probe attenuation factor 1 Press the channel key 2 Press the Probe softkey until you have selected how you want to specify the attenuation factor choosing either Ratio or Decibels 3 Turn the Entry knob tto set the attenuation factor for the connected probe When measuring voltage values the attenuation factor can be set from 0 1 1 to 1000 1 in a 1 2 5 sequence When measuring current values with a current probe the attenuation factor can be set from 10 V A to 0 001 V A When specifying the attenuation factor in decibels you can select values from 20 dB to 60 dB If Amps is chosen as the units and a manual attenuation factor is chosen then the units as well as the attenuation factor are displayed above the Probe softkey To specify the probe skew When measuring time intervals in the nanoseconds ns range small differences in cable length can affect the measurement Use Skew to remove cable delay errors between any two channels 1 Probe the same point with both probes Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Vertical Controls 2 Press one of the probes associated channel key 3 Inthe Channel Menu press Probe 4 Inthe Chan
6. Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 51 2 Horizontal Controls To position the time reference left center right Time reference is the reference point on the display for delay time horizontal position 1 Press Horiz 2 Inthe Horizontal Menu press Time Ref then select Left the time reference is set to one major division from the left edge of the display Center the time reference is set to the center of the display Right the time reference is set to one major division from the right edge of the display A small hollow triangle V at the top of the display grid marks the position of the time reference When delay time is set to zero the trigger point indicator W overlays the time reference indicator The time reference position sets the initial position of the trigger event within acquisition memory and on the display with delay set to 0 Turning the Horizontal scale sweep speed knob expands or contracts the waveform about the time reference point V See To adjust the horizontal time div scale on page 44 Turning the Horizontal position knob in Normal mode not Zoom moves the trigger point indicator W to the left or right of the time reference point V See To adjust the horizontal delay position on page 45 Searching for Events 52 You can use the Search key and menu to search for Serial events on the analog channels Setting up sea
7. ec t this to print horizontally on the page instead of vertically To specify the palette option In the Print Configuration Menu press the Palette softkey to change the following options 238 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Print Screens 19 Color Select this to print the screen in color The oscilloscope s print driver cannot print color images to color laser printers so the Color option is not available when connected to laser printers Grayscale Select this to print the screen in shades of gray rather than in color Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 239 19 Print Screens 240 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 20 Utility Settings 1 0 Interface Settings 241 Setting up the Oscilloscope s LAN Connection 242 File Explorer 245 Setting Oscilloscope Preferences 247 Setting the Oscilloscope s Clock 250 Setting the Rear Panel TRIG OUT Source 250 Performing Service Tasks 251 Configuring the Quick Action Key 256 Adding an Annotation 257 This chapter explains oscilloscope utility functions I O Interface Settings The oscilloscope can be accessed and or controlled remotely via these I O interfaces USB device port on the rear panel square shaped USB port LAN interface when a LAN VGA module is installed in the rear pane
8. local Minimum Overshoot Channels x Measurements Measurement Menu Source Add Settings Clear Meas Measurement a ad gt Figure 34 Automatic Overshoot measurement Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Measurements 14 Preshoot Preshoot is distortion that precedes a major edge transition expressed as a percentage of Amplitude The X cursors show which edge is being measured edge closest to the trigger reference point local Maximum D Top Rising edge preshoot Amplitude x 100 _ Base D local Minimum Falling edge preshoot Amplitude x 100 s Preshoot local Maximum N Preshoo local Minimum Average Average is the sum of the levels of the waveform samples divided by the number of samples Xi Average j Where x value at ith point being measured n number of points in measurement interval The Full Screen measurement interval variation measures the value on all displayed data points The N Cycles measurement interval variation measures the value on an integral number of periods of the displayed signal If less than three edges are present the measurement shows No edges The X cursors show what interval of the waveform is being measured Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 183 14 Measurements 184 DC RMS AC RMS DC RMS is the root mean square value of the waveform over one or more full periods n 2 ae RMS dc
9. 4 In the Network Printer Setup Menu press the Modify softkey then turn the Entry knob to select the network parameter you want to enter The setting that must be entered is Printer Address this is the printer or print server s address in one of the following formats IP address of a network enabled printer for example 192 168 1 100 or 192 168 1 100 650 Optionally a non standard port number can be specified following a colon IP address of a print server followed by the path to the printer for example 192 168 1 100 printers printer name or 192 168 1 100 650 printers printer name Path to a Windows network printer share for example server share When the Printer Address is a Windows network printer share the Modify softkey also lets you enter these settings Network Domain this is the Windows network domain name Username this is your login name for the Windows network domain Password this is your login password for the Windows network domain To clear an entered password press the Clear Password softkey 5 Use the Spell Enter and Delete Character softkeys to enter the network printer settings Spell press this softkey and turn the entry knob to select the character at the current position Enter press this softkey to enter characters and move the cursor to the next character position Delete Character press the Enter softkey until the desired character is highlighted then press
10. 4 Press the Mode softkey and select the TV field of the line you want to trigger on You can choose Line Field1 Line Field2 or Line Alternate 5 Press the Line softkey and select the number of the line you want to examine Alternate Triggering If Line Alternate is selected the oscilloscope will alternately trigger on the selected line number in Field 1 and Field 2 This is a quick way to compare the Field 1 VITS and Field 2 VITS or to check for the correct insertion of the half line at the end of Field 1 Channels Video Trigger Menu Mode Field Holdoff Line Fld1 O Oflds Figure 15 Example Triggering on Line 136 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 133 10 Triggers To trigger on all sync pulses To quickly find maximum video levels you could trigger on all sync pulses When All Lines is selected as the Video trigger mode the oscilloscope will trigger on all horizontal sync pulses 1 Press the Trigger key 2 Inthe Trigger Menu press the Trigger softkey then turn the Entry knob to select Video 3 Press the Settings softkey then press the Standard softkey to select the appropriate TV standard 4 Press the Mode softkey and select All Lines 20 008 Vid Lines Channels Field Holdoff All Lines O Oflds Figure 16 Triggering on All Lines To trigger on a specific field of the video signal To examine the components of a video signal trigger on either Field 1 or Field 2 av
11. 7i Where x value at ith point being measured n number of points in measurement interval The Full Screen measurement interval variation measures the value on all displayed data points The N Cycles measurement interval variation measures the value on an integral number of periods of the displayed signal If less than three edges are present the measurement shows No edges The X cursors show the interval of the waveform being measured AC RMS is the root mean square value of the waveform with the DC component removed It is useful for example for measuring power supply noise The N Cycles measurement interval measures the value on an integral number of periods of the displayed signal If less than three edges are present the measurement shows No edges The X cursors show the interval of the waveform being measured The Full Screen Std Deviation measurement interval variation is an RMS measurement across the full screen with the DC component removed It shows the standard deviation of the displayed voltage values The standard deviation of a measurement is the amount that a measurement varies from the mean value The Mean value of a measurement is the statistical average of the measurement Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Measurements 14 The following figure graphically shows the mean and standard deviation Standard deviation is represented by the Greek letter sigma o For a Ga
12. Load from 230 localized front panel overlay 37 Location 230 246 logic presets waveform generator 215 logic threshold 90 low frequency noise rejection 144 M mask files recall 232 MASK license 283 mask test trigger output 199 251 mask testing 195 mask TRIG OUT signal 251 Math key 34 math operators 68 math transforms 70 math 1 2 69 math 1 2 69 math addition 68 math divide 69 math FFT 70 math functions 65 math multiply 69 math offset 67 math scale 67 math subtract 68 math transform functions on arithmetic operations 66 math units 67 math using waveform math 65 MATLAB binary data 285 Maximum measurement 180 342 maximum sample rate 154 Meas key 35 175 Measure controls 35 measure Quick Measure All 256 measurement category definitions 278 measurement definitions 177 measurement record 227 measurement thresholds 191 measurement window with zoom display 193 measurements 177 measurements automatic 175 measurements delay 178 measurements overshoot 178 measurements phase 178 measurements preshoot 178 measurements time 186 measurements voltage 179 MegaZoom IV 4 mem4M 283 memory depth and sample rate 154 memory segmented 161 menu line 41 Minimum measurement 180 missing acknowledge condition 12C trigger 313 Mode Coupling key trigger 141 model number 254 261 Modify softkey 244 mod
13. external trigger 146 external trigger input impedance 147 external trigger probe attenuation 147 external trigger probe units 147 F f t 66 factory default settings 233 Fall time measurement 188 fast debug AutoScale 249 FFT aliasing 75 FFT DC value 75 FFT measurement hints 74 FFT measurements 70 FFT resolution 74 FFT spectral leakage 77 FFT units 75 FFT vertical units 72 FFT window 71 file explorer 245 file format ASCII 224 file format BIN 224 file format BMP 224 file format CSV 224 file format PNG 224 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide File keys 35 file name new 230 file save recall load 245 fine adjustment horizontal scale 51 firmware updates 284 firmware upgrade files 273 firmware version information 261 firmware versions 272 flash drive 36 Flat top FFT window 72 FM frequency modulation waveform generator output 218 folding frequency 151 forcing a trigger 121 frame trigger I2C 314 freeze display 257 freeze display Quick Freeze Display 257 French front panel overlays 38 French user interface and Quick Help 42 frequency deviation FM modulation 219 Frequency measurement 187 frequency modulation FM waveform generator output 218 frequency requirements power source 25 frequency Nyquist 151 frequency shift keying modulation FSK waveform generator output 219 front panel co
14. softkeys 6 31 software updates 284 software version 254 Span FFT 71 Spanish front panel overlays 38 Spanish user interface and Quick Help 42 specifications 277 spectral leakage FFT 77 SPI serial decode 324 SPI trigger 323 square waveform generator output 213 square waves 152 stand alone connection 244 start acquisition 33 start condition I2C 313 344 statistics mask test 200 status line 41 status User Cal 255 Std Deviation measurement 184 stop acquisition 33 stop condition I2C 313 storage locations navigate 230 subnet mask 243 subtract math function 68 sync pulse waveform generator 214 T template front panel 37 test mask 195 Thai front panel overlays 38 theory sampling 151 threshold analog channel measurements 191 threshold digital channels 90 thumb drive 36 tilt for viewing 24 time measurements 186 time reference indicator 52 time re arm 163 timebase 46 times for saving data 228 Tools keys 32 Top measurement 180 totalizer CAN 301 totalizer UART rs232 335 tracking cursors 166 trademarks 2 Traditional Chinese front panel overlays 38 Traditional Chinese user interface and Quick Help 42 transforms math 70 transient withstand capability 278 Transparent backgrounds 248 TRIG OUT connector 39 250 Trig d trigger indicator 143 Trig d trigger indicator 143 Trigger controls 32 trigger coupling 143
15. trigger indicator Auto 143 trigger indicator Trig d 143 trigger indicator Trig d 143 trigger level 120 trigger mode auto or normal 142 trigger mode Quick Trigger Mode 257 trigger output 250 trigger output mask test 199 251 trigger type CAN 297 trigger type edge 121 trigger type glitch 126 trigger type hex bus 126 trigger type 12C 312 trigger type LIN 305 trigger type pattern 124 trigger type pulse width 126 trigger type RS232 331 trigger type slope 121 trigger type SPI 323 trigger type UART 331 trigger type video 129 trigger types 119 trigger definition 120 trigger external 146 trigger forcing a 121 trigger general information 120 trigger holdoff 145 trigger mode coupling 141 trigger source 121 triggers TRIG OUT signal 250 TTL threshold 90 turn channel on 35 U UART totalizer 335 UART trigger 331 UART RS232 frame counter 335 UART RS232 license 283 UART RS232 serial decode 333 under sampled signals 151 units cursor 167 units external trigger probe 147 units math 67 units probe 61 updating software and firmware 284 upgrade files 273 upgrade options 283 upgrading the oscilloscope 284 upload new firmware 261 usb 247 USB device port 40 USB device port remote control 241 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide USB host port 40 235 USB host ports 36 USB printer 235 USB
16. wh location as 0 Ratio en selected use the Use X Cursors softkey to set the current X1 degrees and the current X2 location as 360 degrees when selected use the Use X Cursors softkey to set the current X1 location as 0 and the current X2 location as 100 You can press the Y Units softkey to select Base the Ratio same units used for the source waveform wh en selected use the Use Y Cursors softkey to set the current Y1 location as 0 and the current Y2 location as 100 For phase or ratio units once the O and 360 degree or 0 and 100 locations are set adjusting cursors will display measurements relative to the set locations 7 Adjust the selected cursor s by turning the Cursors knob Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Cursors 13 Cursor Examples Channels Cursors Cursors Menu Mode Cursors Manual wil Figure 28 Cursors used to measure pulse widths other than middle threshold points Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 169 13 Cursors 100 08 KEYSIGHT TECHNO Acquisition Channels Cursors Mode Source Cursors Manual X2 Figure 29 Cursors measure frequency of pulse ringing Expand the display with Zoom mode then characterize the event of interest with the cursors 170 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 20 008 Source Cursors Units Manual 2 Fig
17. 186 persistence 109 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide persistence clearing 110 persistence infinite 150 Phase measurement 178 190 phase X cursor units 168 PNG file format 224 point to point connection 244 Polish front panel overlays 38 pollution degree 279 pollution degree definitions 279 Portuguese front panel overlays 38 Portuguese user interface and Quick Help 42 position digital channels 91 position knob 91 position analog 59 post processing 175 post trigger information 45 power consumption 25 power cord connector 39 power requirements 25 power supply 39 power switch 26 31 power on 25 predefined labels 114 Preshoot measurement 178 183 Press to go 230 246 pre trigger information 45 print 256 Print key 35 print options 238 print screen 235 print landscape 238 print Quick Print 256 printer USB 36 235 printing the display 235 probe attenuation 62 probe attenuation external trigger 147 probe compensation 36 probe units 61 probes 279 280 282 probes connecting to oscilloscope 26 probes current 281 probes differential 281 probes digital 83 probes passive 280 probes passive compensating 29 programmer s guide 269 pulse polarity 127 pulse waveform generator output 213 pulse width trigger 126 Q qualifier pulse width 128 Quick Action key 32 256 Quick Clear Display 25
18. 2 Press the softkey in the second position and use the Entry knob to navigate to the file to recall See To navigate storage locations on page 230 3 Press the Press to Recall softkey Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 231 18 Save Recall Setups Screens Data A message indicating whether the recall was successful is displayed 4 lf you would like to clear the display press Clear Display To recall mask files Mask files can be recalled from one of four internal Keysight Flash locations or from an external USB storage device 1 Press Save Recall gt Recall gt Recall then turn the Entry knob to select Mask msk Press the softkey in the second position and use the Entry knob to navigate to the file to recall See To navigate storage locations on page 230 Press the Press to Recall softkey A message indicating whether the recall was successful is displayed If you would like to clear the display or clear the recalled mask press Clear Display or Clear Mask To recall reference waveform files from a USB storage device Press the Save Recall key 2 Inthe Save Recall Menu press the Recall softkey 3 In the Recall Menu press the Recall softkey and turn the Entry knob to select Reference Waveform data h5 Press the To Ref softkey and turn the Entry knob to select the desired reference waveform location Press the softkey in the second position and use t
19. 283 Other Options Available 284 Upgrading toan MSO 284 Software and Firmware Updates 284 Binary Data bin Format 284 Binary Datain MATLAB 285 Binary Header Format 286 Example Program for Reading Binary Data 288 Examples of Binary Files 288 CSV and ASCII XY files 291 CSV and ASCII XY file structure 292 Minimum and Maximum Values in CSV Files 292 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Acknowledgements 293 23 CAN LIN Triggering and Serial Decode Setup for CAN Signals 295 CAN Triggering 297 CAN Serial Decode 298 Interpreting CAN Decode 300 CAN Totalizer 301 Interpreting CAN Lister Data 302 Searching for CAN Data in the Lister 303 Setup for LIN Signals 303 LIN Triggering 305 LIN Serial Decode 306 Interpreting LIN Decode 308 Interpreting LIN Lister Data 309 Searching for LIN Data in the Lister 310 24 2C SPI Triggering and Serial Decode Setup for 12C Signals 311 12C Triggering 312 I2C Serial Decode 316 Interpreting I2C Decode 317 Interpreting 12C Lister Data 318 Searching for 12C Data inthe Lister 318 Setup for SPI Signals 319 SPI Triggering 323 SPI Serial Decode 324 Interpreting SPI Decode 326 Interpreting SPI Lister Data 327 18 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Searching for SPI Data in the Lister 327 25 UART RS232 Triggering and Serial Decode Setup for UART RS232 Signals
20. Address values appear at the start of a frame Write addresses appear in light blue along with the W character Read addresses appear in yellow along with the R character Restart addresses appear in green along with the S character Data values appear in white A indicates Ack low A indicates No Ack high Decoded text is truncated at the end of the associated frame when there is insufficient space within frame boundaries Pink vertical bars indicate you need to expand the horizontal scale and run again to see decode Red dots in the decode line indicate that more data can be displayed Scroll or expand the horizontal scale to view the data Aliased bus values undersampled or indeterminate are drawn in pink Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 317 24 2C SPI Triggering and Serial Decode Unknown bus values undefined or error conditions are drawn in red Interpreting 12C Lister Data 1 00 1 00 384 05 101 5857 Stop 2c 1 40 Time Restart Address Data Missing Ack KEYSIGHT 26 84ms TECHNOLOGIES 3 234ms t2 662m Acquisition 1 522ms gt 138 0us he Channels 1 482ms 2 162ms Data FF 80 Options w In addition to the standard Time column the I2C Lister contains these columns Restart indicated with an X Address colored blue for writes yellow for reads Data data bytes Missing Ack i
21. Press to go when you can push the Entry knob to navigate to a new folder or storage location Location when pointing to a directory that is currently selected Selected when pointing to a file that can be loaded or deleted When this label appears you can press the Load File or Delete File softkeys to take the action Pushing the Entry knob is the same as pressing the Load File softkey A file that has been deleted from a USB storage device cannot be recovered by the oscilloscope Use your PC to create directories on a USB storage device Most USB mass storage devices are compatible with the oscilloscope However certain devices may be incompatible and may not be able to be read or written to When the USB mass storage device is connected to the oscilloscope s front or rear USB host port a small four color circle icon may be displayed briefly as the USB device is read Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Utility Settings 20 You do not need to eject the USB mass storage device before removing it Simply ensure that any file operation you ve initiated is done and remove the USB drive from the oscilloscope s host port Do not connect USB devices that identify themselves as hardware type CD because these devices are not compatible with the InfiniiVision X Series oscilloscopes If two USB mass storage devices are connected to the oscilloscope the first one is designated usb and t
22. SPI Master In Slave Out Menu MISO Data Threshold Display Info 1 44V In the SPI Master In Slave Out Menu a Press the MISO Data softkey then turn the Entry knob to select the channel that is connected to a second SPI serial data line If the channel you selected is off switch it on The MISO label for the source channel is automatically set b Press the Threshold softkey then turn the Entry knob to select the MISO signal threshold voltage level The threshold voltage level is used in decoding and it will become the trigger level when the trigger type is set to the selected serial decode slot 8 Press the CS softkey to open the SPI Chip Select Menu 5 00 5 00V 5 00V SP 1 44 KEYSIGHT TECHNOLOGIES Acquisition Channels Trigger Paint T DATA TaN XN _X FF FF FF FF FE FF FF 7F X FR Fr O2 FF FF FF 02 10 4D 53 4F SPI Chip Select Menu 06 05 FFX02 20 21 Threshold Display Info 1 44y Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 321 24 2C SPI Triggering and Serial Decode In the SPI Chip Select Menu a Press the Frame by softkey to select a framing signal that the oscilloscope will use for determining which clock edge is the first clock edge in the serial stream You can set the oscilloscope to trigger during a high chip select CS a low chip select CS or after a Timeout period during which the clock signal has been idle If the framing signal is set to CS or CS t
23. Segment lof 3 0 0s Segmented Current Seg of Segs 1 25 See Also Navigating Segments on page 162 Infinite Persistence with Segmented Memory on page 163 Segmented Memory Re Arm Time on page 163 Saving Data from Segmented Memory on page 163 Navigating Segments 1 Press the Current Seg softkey and turn the Entry knob to display the desired segment along with a time tag indicating the time from the first trigger event You can also navigate segments using the Navigate key and controls See To navigate segments on page 54 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Acquisition Control 12 Infinite Persistence with Segmented Memory When data has been acquired to segmented memory you can also turn on infinite persistence in the Display Menu and press the Analyze Segments softkey to create an infinite persistence display The Analyze Segments softkey appears when the acquisition is stopped and the segmented memory feature is on Segmented Memory Re Arm Time After each segment fills the oscilloscope re arms and is ready to trigger in about 8 US Remember though for example if the horizontal time per division control is set to 5 us div and the Time Reference is set to Center it will take at least 50 us to fill all ten divisions and re arm That is 25 us to capture pre trigger data and 25 us to capture post trigger data 2 0005 500 08 Segment Sof 25 4 00050ms Segment 1
24. Symbols Width measurement 188 Width measurement 188 A About Oscilloscope 254 AC channel coupling 60 AC RMS Full Screen measurement 184 AC RMS N Cycles measurement 184 accessories 21 279 280 282 acquire 149 159 Acquire key 35 acquisition memory 120 acquisition memory saving 227 acquisition mode 155 acquisition mode averaging 158 159 acquisition mode high resolution 160 acquisition mode normal 156 acquisition mode peak detect 156 acquisition mode preserve during AutoScale 249 acquisition modes 149 active serial bus 300 308 317 326 334 activity indicator 89 actual sample rate 154 adding digital channels license 284 addition math function 68 address with no ack condition 12C trigger 313 Addresses softkey 244 aliasing 151 aliasing FFT 75 alternating edge trigger 123 AM amplitude modulation waveform generator output 217 Amplitude measurement 180 amplitude modulation AM waveform generator output 217 analog channel probe attenuation 62 analog channel setup 57 analog filters adjusting 71 Analyze key 32 Analyze Segments 161 163 annotation adding 257 ASCII file format 224 attenuation probe 62 attenuation probe external trigger 147 Auto Increment 231 AUTO Option 283 Auto Scale key 33 Auto Setup FFT 72 Auto trigger mode 142 Auto trigger indicator 143 AutolP 243 244 automatic measurements 175 177 automat
25. The displayed waveform will expand about the center of the display To disable enable transparent backgrounds There is a preference setting for whether measurements statistics reference waveform information and other text displays have transparent or solid backgrounds 1 Press Utility gt Options gt Preferences 2 Press Transparent to toggle between transparent and solid text display backgrounds To load the default label library See To reset the label library to the factory default on page 117 To set up the screen saver The oscilloscope can be configured to turn on a display screen saver when the oscilloscope has been idle for a specified length of time 1 Press Utility gt Options gt Preferences gt Screen Saver to display the Screen Saver Menu Wait 180min Preview 2 Press the Saver softkey to select the screen saver type The screen saver can be set to Off to display any of the images shown in the list or can display a user defined text string If User is selected press the Spell softkey to select the first character of the text string Use the Entry knob to choose a character Then press the Enter softkey to advance to the next character and repeat the process You can use a connected USB keyboard instead of using the Spell and other character editing softkeys Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Utility Settings 20 The resultant string is displayed i
26. Trigger Menu Press the Field Holdoff softkey and use the Entry knob to adjust the holdoff in half field increments until the oscilloscope triggers on only one phase of the color burst A quick way to synchronize to the other phase is to briefly disconnect the signal and then reconnect it Repeat until the correct phase is displayed When holdoff is adjusted using the Field Holdoff softkey and the Entry knob the corresponding holdoff time will be displayed in the Trigger Mode and Coupling Menu Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 137 10 Triggers Table 4 Half field holdoff time Standard Time NTSC 8 35 ms PAL 10 ms PAL M 10 ms SECAM 10 ms 424 05 500 08 MEEN Video Trigger Menu Mode Field Holdoff Field1 3 0000flds Figure 20 Using Field Holdoff to Synchronize to Color Field 1 or 3 Field 1 mode Serial Trigger With serial decode option licenses see Serial Decode Options on page 101 you can enable serial trigger types To set up these triggers see CAN Triggering on page 297 I2C Triggering on page 312 LIN Triggering on page 305 138 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Triggers 10 SPI Triggering on page 323 UART RS232 Triggering on page 331 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 139 10 Triggers 140 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysigh
27. key is off The waveform generator output is always disabled when the instrument is first turned on The waveform generator output is automatically disabled if excessive voltage is applied to the Gen Out BNC KEYSIGHT TECHNOLOGIES 211 17 Waveform Generator 2 In the Waveform Generator Menu press the Waveform softkey and turn the Entry knob to select the waveform type 500 05 Acquisition rmal Channels Ramp Pulse DC a velenu m v Sine Waveform Frequency Amplitude Offset Settings AS Sine 1 000kHz 500mVpp 0 0v v 3 Depending on the selected waveform type use the remaining softkeys and the Entry knob to set the waveform s characteristics 212 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Waveform Type Sine Waveform Generator 17 Characteristics Use the Frequency Frequency Fine Period Period Fine Amplitude High Level and Offset Low Level softkeys to set the sine signal parameters The frequency can be adjusted from 100 mHz to 20 MHz Square Use the Frequency Frequency Fine Period Period Fine Amplitude High Level Offset Low Level and Duty Cycle softkeys to set the square wave signal parameters The frequency can be adjusted from 100 mHz to 10 MHz The duty cycle can be adjusted from 20 to 80 Ramp Use the Frequency Frequency Fine Period Period Fine Amplitude High Level Offset Low Level and Symmetry softkeys to set the ramp signal parameters The freque
28. negative pulse the trigger will occur on the low to high transition of the pulse if the qualifying condition is true 6 Press the qualifier softkey lt gt gt lt to select the time qualifier The Qualifier softkey can set the oscilloscope to trigger on a pulse width that is Less than a time value lt For example for a positive pulse if you set t lt 10 ns K 10 ns oe k 10 ns gt Trigger Greater than a time value gt For example for a positive pulse if you set t gt 10 ns K 10 ns 10 ns __ Tigger Within a range of time values gt lt For example for a positive pulse if you set t gt 10 ns and t lt 15 ns k 10ns 4 H 15 ns gt k 12ns __ Trigger m L l 7 Select the qualifier time set softkey lt or gt then rotate the Entry knob to set the pulse width qualifier time The qualifiers can be set as follows 2 ns to 10 s for gt or lt qualifier 5 ns to 10 s for 350 MHz bandwidth models 10 nsto 10 s for gt lt qualifier with minimum difference of 5 ns between upper and lower settings When the less than lt qualifier is selected the Entry knob sets the oscilloscope to trigger on a pulse width less than the time value displayed on the softkey When the time range gt lt qualifier is selected the Entry knob sets the upper time range value Keysight InfiniiVision 2000 X Series O
29. oscilloscopes have a Gaussian frequency response 152 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Acquisition Control 12 OdB 3dB 2 w c o lt i Aliased frequency components i fg4 fN fs FrequenCy me Limiting oscilloscope bandwidth few to 1 4 the sample rate fs 4 reduces frequency components above the Nyquist frequency fn Figure 23 Sample Rate and Oscilloscope Bandwidth So in practice an oscilloscope s sample rate should be four or more times its bandwidth fs 4fgw This way there is less aliasing and aliased frequency components have a greater amount of attenuation SeeAlso Evaluating Oscilloscope Sample Rates vs Sampling Fidelity How to Make the Most Accurate Digital Measurements Keysight Application Note 1587 http literature cdn keysight com litweb pdf 5989 5732EN pdf Oscilloscope Rise Time Closely related to an oscilloscope s bandwidth specification is its rise time specification Oscilloscopes with a Gaussian type frequency response have an approximate rise time of 0 35 fgy based on a 10 to 90 criterion An oscilloscope s rise time is not the fastest edge speed that the oscilloscope can accurately measure It is the fastest edge speed the oscilloscope can possibly produce Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 153 12 Acquisition Control 154 Oscilloscope Bandwidth Required See Also The oscilloscope bandwidth required to
30. 104 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Serial Decode 7 Each serial decode option lets you find protocol specific headers data errors etc See Searching for CAN Data in the Lister on page 303 Searching for I2C Data in the Lister on page 318 Searching for LIN Data in the Lister on page 310 Searching for SPI Data in the Lister on page 327 Searching for UART RS232 Data in the Lister on page 336 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 105 7 Serial Decode 106 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Display Settings To adjust waveform intensity 107 To set or clear persistence 109 To clear the display 110 To select the grid type 110 To adjust the grid intensity 111 To freeze the display 111 To adjust waveform intensity You can adjust the intensity of displayed waveforms to account for various signal characteristics such as fast time div settings and low trigger rates Increasing the intensity lets you see the maximum amount of noise and infrequently occurring events Reducing the intensity can expose more detail in complex signals as shown in the following figures 1 Press the Intensity key to illuminate it This key is located just below the Entry knob 2 Turn the Entry knob to adjust the waveform instensity Waveform intensity adjustment affe
31. 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter The Digital Voltmeter DVM analysis feature provides 3 digit voltage and 5 digit frequency measurements using any analog channel DVM measurements are asynchronous from the oscilloscope s acquisition system and are always acquiring To enable the digital voltmeter analysis feature order Option DVM at time of oscilloscope purchase or order DSOXDVM as a stand alone item after oscilloscope purchase The DVM display is a seven segment readout like you would see on a digital voltmeter It shows the selected mode as well as the units Units are selected using the Units softkey in the channel s Probe Menu After pressing the Analyze key the DVM display also appears in the graticule along with a scale and the frequency counter value The DVM scale is determined by the channel s vertical scale and reference level The scale s blue triangle pointer shows the most recent measurement The white bar above that shows the measurement extrema over the last 3 seconds KEYSIGHT TECHNOLOGIES 207 16 Digital Voltmeter 208 Source DYM The DVM makes accu 100 057 Auto 6259 TECHNOLOGIES DVM Channels Frequency Mode Transparent Auto Range AC RMS rate RMS measurements when the signal frequency is between 20 Hz and 100 kHz When the signal frequency is outside this range lt BW Limit
32. 329 UART RS232 Triggering 331 UART RS232 Serial Decode 333 Interpreting UART RS232 Decode 334 UART RS232 Totalizer 335 Interpreting UART RS232 Lister Data 336 Searching for UART RS232 Data in the Lister 336 Index Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 20 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 1 Getting Started Inspect the Package Contents 21 Tilt the Oscilloscope for Easy Viewing 24 Power On the Oscilloscope 25 Connect Probes to the Oscilloscope 26 Input a Waveform 27 Recall the Default Oscilloscope Setup 27 Use Auto Scale 28 Compensate Passive Probes 29 Learn the Front Panel Controls and Connectors 30 Learn the Rear Panel Connectors 38 Learn the Oscilloscope Display 40 Access the Built In Quick Help 41 This chapter describes the steps you take when using the oscilloscope for the first time Inspect the Package Contents Inspect the shipping container for damage If your shipping container appears to be damaged keep the shipping container or cushioning material until you have inspected the contents of the shipment for completeness and have checked the oscilloscope mechanically and electrically Verify that you received the following items and any optional accessories you may have ordered KEYSIGHT TECHNOLOGIES 21 1 Getting Started InfiniiVision 2000
33. 6 Begin the Self Cal by pressing the Start User Cal softkey To perform hardware self test Pressing Utility gt Service gt Hard ware Self Test performs a series of internal procedures to verify that the oscilloscope is operating properly It is recommended you run Hardware Self Test After experiencing abnormal operation For additional information to better describe an oscilloscope failure To verify proper operation after the oscilloscope has been repaired Successfully passing Hardware Self Test does not guarantee 100 of the oscilloscope s functionality Hardware Self Test is designed to provide an 80 confidence level that the oscilloscope is operating properly To perform front panel self test Pressing Utility gt Service gt Front Panel Self Test lets you test the front panel keys and knobs as well as the oscilloscope display Follow the on screen instructions To display oscilloscope information Press Help gt About Oscilloscope to display information about your oscilloscope Model number Serial number Bandwidth Module installed Software version Installed licenses See also Loading Licenses and Displaying License Information on page 282 204 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Utility Settings 20 To display the user calibration status Pressing Utility gt Service gt User Cal Status displays the summary results of the previous User Cal and the status of prob
34. Base 53 The horizontal controls include The horizontal scale and position knobs The Horiz key for accessing the Horizontal Menu The zoom key for quickly enabling disabling the split screen zoom display The Search key for finding events on analog channels or in serial decode The Navigate keys for navigating time search events or segmented memory acquisitions The following figure shows the Horizontal Menu which appears after pressing the Horiz key KEYSIGHT TECHNOLOGIES 43 2 Horizontal Controls Trigger Time Delay Time Trigger Trigger level point reference time div source or threshold N 100 05 Sample rate Channels XY or Roll ral il mode x Time Mod TLIUN SSG KiB Time Ref Normal Center Fd J J Normal Zoomed Fine Time time mode time base control reference Figure 2 Horizontal Menu The Horizontal Menu lets you select the time mode Normal XY or Roll enable Zoom set the time base fine control vernier and specify the time reference The current sample rate is displayed above the Fine and Time Ref softkeys To adjust the horizontal time div scale 1 Turn the large horizontal scale sweep speed knob marked N Ay to change the horizontal time div setting Notice how the time div information in the status line changes 44 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Horizontal Controls 2 The V symbol at the top of t
35. CSV data This analysis record or measurement record is much larger than 640 and may in fact contain up to 65536 points Still once the of acquired points gt 65536 some form of decimation is required The decimator used to produce a CSV record is configured to provide a best estimate of all the samples that each point in the record represents Therefore the min and max values may not appear in the CSV file Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Reference 22 Acknowledgements RealVNC HDF5 CUPS mDNSResponder Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide RealVNC is licensed under the GNU General Public License Copyright C 2002 2005 RealVNC Ltd All Rights Reserved This is free software you can redistribute it and or modify it under the terms of the GNU General Public License as published by the Free Software Foundation either version 2 of the License or at your option any later version This software is distributed in the hope that it will be useful but WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU General Public License for more details This license is located on the Keysight InfiniiVision Oscilloscopes Documentation CD ROM RealVNC source code can be obtained from RealVNC or by contacting Keysight Keysight will charge for the cost of physically performing the source distribution
36. Channel 2 ground ___ level Channel 1 Menu Coupling BW Limit DC The ground level of the signal for each displayed analog channel is identified by the position of the icon at the far left side of the display To turn waveforms on or off channel or math 1 Press an analog channel key turn the channel on or off and to display the channel s menu When a channel is on its key is illuminated Turning channels off You must be viewing the menu for a channel before you can turn it off For example if channel 1 and channel 2 are turned on and the menu for channel 2 is being displayed to turn channel 1 off press 1 to display the channel 1 menu then press 1 again to turn channel 1 off 58 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Vertical Controls 3 To adjust the vertical scale 1 Turn the large knob above the channel key marked A N to set the vertical scale volts division for the channel The vertical scale knob changes the analog channel scale in a 1 2 5 step sequence with a 1 1 probe attached unless fine adjustment is enabled see To change the vertical scale knob s coarse fine adjustment setting on page 60 The analog channel Volts Div value is displayed in the status line The default mode for expanding the signal when you turn the volts division knob is vertical expansion about the ground level of the channel however you can change this to expand about the center of the
37. Interface on page 262 2 When the oscilloscope s web interface is displayed select the Save Recall tab from the left side of the Welcome screen 3 Click the Recall link 270 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Web Interface 21 4 On the Recall page a Click Browse b Inthe Choose file dialog select the file you want to recall then click Open c When recalling reference waveform data files select the To Reference Waveform location Support KEYSIGHT i Another wq pea x Mala C Temp web_interface scope h5 Cee aoe R1 v R1 d Click Recall Get Image To save or print the oscilloscope s display from the web interface 1 Access the oscilloscope s web interface see Accessing the Web Interface on page 262 2 When the oscilloscope s web interface is displayed select the Get Image tab from the left side of the Welcome screen After a delay of several seconds the oscilloscope s screen image will be displayed 3 Right click on the image and select Save Picture As or Print Picture 4 Select a storage location for the image file and click Save Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 271 21 Web Interface Identification Function The Identification web interface feature is useful when trying to locate a specific instrument in a rack of equipment 1 Access the oscilloscope s web interface see Accessing the Web Interface o
38. Meas key and set the Source softkey to Math f t You can make peak to peak maximum minimum and average dB measurements on the FFT waveform You can also find the frequency value at the first occurrence of the waveform maximum by using the X at Max Y measurement The following FFT spectrum was obtained by connecting a 4 V 75 kHz square wave to channel 1 Set the horizontal scale to 50 us div vertical sensitivity to 1 V div Units div to 20 dBV Offset to 60 0 dBV Center frequency to 250 kHz frequency Span to 500 kHz and window to Hanning Channels hi Measurements MELE Freq 1 74 63kHz Pk Pk 1 FFT Ch1 Scale 20dB ffset 60 000dBY FFT Resolution 763H2 Window Vertical Units Hanning Decibels Auto Setup See Also To perform a transform function on an arithmetic operation on page 66 FFT Measurement Hints on page 74 FFT Units on page 75 FFT DC Value on page 75 FFT Aliasing on page 75 FFT Spectral Leakage on page 77 Units for Math Waveforms on page 67 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 73 4 74 Math Waveforms FFT Measurement Hints The number of points acquired for the FFT record can be up to 65 536 and when frequency span is at maximum all points are displayed Once the FFT spectrum displayed the frequency span and center frequency controls are used much like the controls of a spectrum analyzer to examine the frequency of interest i
39. Mode Coupling key to set options that affect all trigger types see Chapter 11 Trigger Mode Coupling starting on page 141 KEYSIGHT TECHNOLOGIES 119 10 Triggers Triggers General Information You can save trigger setups along with the oscilloscope setup see Chapter 18 Save Recall Setups Screens Data starting on page 223 A triggered waveform is one in which the oscilloscope begins tracing displaying the waveform from the left side of the display to the right each time a particular trigger condition is met This provides stable display of periodic signals such as sine waves and square waves as well as nonperiodic signals such as serial data streams The figure below shows the conceptual representation of acquisition memory You can think of the trigger event as dividing acquisition memory into a pre trigger and post trigger buffer The position of the trigger event in acquisition memory is defined by the time reference point and the delay horizontal position setting see To adjust the horizontal delay position on page 45 Trigger Event Pre Trigger Buffer Post Trigger Buffer Pi y Acquisition Memory Adjusting the Trigger Level 120 You can adjust the trigger level for a selected analog channel by turning the Trigger Level knob You can push the Trigger Level knob to set the level to the waveform s 50 value If AC coupling is used pushing the Trigger Level knob sets the trig
40. Press the Source softkey and turn the Entry knob to select the source waveform 5 Press the softkey in the second position and use the Entry knob to navigate to the save location See To navigate storage locations on page 230 6 Finally press the Press to Save softkey A message indicating whether the save was successful is displayed To save masks Mask files can be saved to one of four internal Keysight Flash locations or to an external USB storage device 1 Press Save Recall gt Save gt Format then turn the Entry knob to select Mask msk 2 Press the softkey in the second position and use the Entry knob to navigate to the save location See To navigate storage locations on page 230 3 Finally press the Press to Save softkey A message indicating whether the save was successful is displayed Mask files have the extension MSK Masks are also saved as part of setup files See To save setup files on page 225 See Also Chapter 15 Mask Testing starting on page 195 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 229 18 Save Recall Setups Screens Data To navigate storage locations When saving or recalling files the softkey in the second position of the Save Menu or Recall Menu along with the Entry knob are used to navigate to storage locations The storage locations can be internal oscilloscope storage locations for setup files or mask files or they can be external s
41. Reference Waveform files use HDF5 HDF5 was developed by The HDF Group and by the National Center for Supercomputing Applications at the University of Illinois at Urbana Champaign Network printing uses the CUPS Common Unix Printing System library The CUPS and CUPS Imaging libraries are developed by Apple Inc and licensed under the GNU Library General Public License LGPL Version 2 This license is located on the Keysight InfiniiVision Oscilloscopes Documentation CD ROM CUPS network printing uses the mDNSResponder library The mDNSResponder library is developed by Apple Inc and licensed under the Apache License Version 2 0 This license is located on the Keysight InfiniiVision Oscilloscopes Documentation CD ROM 293 22 Reference 294 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 23 CAN LIN Triggering and serial Decode Setup for CAN Signals 295 CAN Triggering 297 CAN Serial Decode 298 Setup for LIN Signals 303 LIN Triggering 305 LIN Serial Decode 306 CAN LIN triggering and serial decode requires Option AUTO or the DSOX3AUTO upgrade Setup for CAN Signals Setup consists of connecting the oscilloscope to a CAN signal using the Signals Menu to specify the signal source threshold voltage level baud rate and sample point To set up the oscilloscope to capture CAN signals use the Signals softkey which
42. Serial Decode To display digital channels using AutoScale 87 Interpreting the digital waveform display 88 To change the displayed size of the digital channels 89 To switch a single channel on or off 89 To switch all digital channels on or off 89 To switch groups of channels on or off 90 To change the logic threshold for digital channels 90 To reposition a digital channel 91 To display digital channels asabus 91 Digital channel signal fidelity Probe impedance and grounding 94 Input Impedance 94 Probe Grounding 96 Best Probing Practices 98 To replace digital probe leads 98 Serial Decode Options 101 Lister 102 Searching Lister Data 104 8 Display Settings To adjust waveform intensity 107 To set or clear persistence 109 To clear the display 110 To select the gridtype 110 To adjust the grid intensity 111 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide To freeze the display 111 9 Labels To turn the label display on or off 113 To assign a predefined label to a channel 114 To define anew label 115 To load a list of labels from a text file you create 116 To reset the label library to the factory default 117 10 Triggers Adjusting the Trigger Level 120 Forcing aTrigger 121 Edge Trigger 121 Pattern Trigger 124 Hex Bus Pattern Trigger 126 Pulse Width Trigger 126 Video Trigger 129 To trigger on a specific line of video 132 To
43. Test Menu then press the Clear Mask softkey If infinite persistence display mode see To set or clear persistence on page 109 is on when mask test is enabled it stays on If infinite persistence is off when mask test is enabled it is switched on when mask test is switched on then infinite persistence is switched off when mask test is switched off Troubleshooting If you press Create Mask and the mask appears to cover the entire screen check the Mask Setup Y and X settings in the Automask Menu If these are set to zero the resulting mask will be extremely tight around the waveform If you press Create Mask and it appears that no mask was created check the Y and X settings They may be set so large that the mask is not visible Mask Test Setup Options From the Mask Test Menu press the Setup softkey to enter the Mask Setup Menu Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 197 15 Mask Testing 198 Run Until The Run Until softkey lets you specify a condition on which to terminate testing Forever The oscilloscope runs continuously However if an error occurs the action specified using the On Error softkey will occur Minimum of Tests Choose this option and then use the of Tests softkey to select the number of times the oscilloscope will trigger display the waveform s and compare them to the mask The oscilloscope will stop after the specified number of tests have b
44. User s Guide 4 Enter your desired password and click Apply Changes 275 21 Web Interface Support Pro Ww KEYSIGHT PRT another web TECHNOLOGIES _ from Keysight Modify Network Configuration Undo Changes LANReset Apply Changes Parameter Configured Value Edit Configuration IP Settings may be configured using the following Automatic ON OFF ON IP Settings to use in non automatic mode 49 aa5 IP Address 141 121 237 192 Subnet Mask 255 255 248 0 Default Gateway 141 121 232 1 Name service settings a mx2024a 10029 gt Help with ad this Page Hostname a mx2024a 10029 Requires reboot to take effect DNS Server 156 140 24 15 156 140 24 15 Multicast DNS ON OFF ON Other settings Agilent MSOX2024A InfiniiVision r aiaia aN Description US50210029 Agilent MSOX2024A InfiniiVision L Enter password GPIB Address 7 7 Set to blank for factory default value When accessing the password protected oscilloscope the user name is the IP address of the oscilloscope Toresetthe Do one of these things to reset the password password Using the keys on the front panel of the oscilloscope press Utility gt 1 0 gt LAN Reset Using the web browser select the Configure Network tab select Modify Configuration erase the Password and select Apply Changes 2 6 Keysight InfiniiVision 200
45. a Keysight proprietary format that can be read by Keysight InfiniiVision oscilloscopes A mask data file includes some oscilloscope setup information but not all setup information To save all setup information including the mask data file choose Setup scp format instead See To save masks on page 229 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Save Recall Setups Screens Data 18 You can also configure the Quick Action key to save setups screen images or data See Configuring the Quick Action Key on page 256 To save setup files Setup files can be saved to one of 10 internal Keysight Flash locations or to an external USB storage device 1 Press Save Recall gt Save gt Format then turn the Entry knob to select Setup scp 2 Press the softkey in the second position and use the Entry knob to navigate to the save location See To navigate storage locations on page 230 3 Finally press the Press to Save softkey A message indicating whether the save was successful is displayed Setup files have the extension SCP These extensions appear when using the File Explorer see File Explorer on page 245 but they do not appear when using the Recall Menu To save BMP or PNG image files Image files can be saved to an external USB storage device 1 Press Save Recall gt Save gt Format then turn the Entry knob to select 8 bit Bitmap image bmp 24 bit Bitmap image b
46. a reference waveform file on a USB storage device See To save reference waveform files to a USB storage device on page 229 You can recall a reference waveform file from a USB storage device into one of the reference waveform locations See To recall reference waveform files from a USB storage device on page 232 82 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels To connect the digital probes to the device under test 83 Acquiring waveforms using the digital channels 87 To display digital channels using AutoScale 87 Interpreting the digital waveform display 88 To switch all digital channels on or off 89 To switch groups of channels on or off 90 To switch a single channel on or off 89 To change the displayed size of the digital channels 89 To reposition a digital channel 91 To change the logic threshold for digital channels 90 To display digital channels as a bus 91 Digital channel signal fidelity Probe impedance and grounding 94 To replace digital probe leads 98 This chapter describes how to use the digital channels of a Mixed Signal Oscilloscope MSO The digital channels are enabled on MSOX2000 X Series models and DSOX2000 X Series models that have the DSOX2MSO upgrade license installed Digital channels and serial decode cannot be on at the same time The Serial key takes precedence ove
47. a stop condition EEPROM Data Read The trigger looks for EEPROM control byte value 101 Oxxx on the SDA line followed by a Read bit and an Ack bit It then looks for the data value and qualifier set by the Data softkey and the Datais softkey When this event occurs the oscilloscope will trigger on the clock edge for the Ack bit after the data byte This data byte does not need to occur directly after the control byte Read a ai SDA N 1010xxx JN X scl T 1 1 7 JS 11 8 ao ioe L J L J L ft J J Startor Control R Ack Data Ack Restart byte Trigger point Condition Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 313 24 314 12C SPI Triggering and Serial Decode Frame Start Addr7 Read Ack Data or Frame Start Addr7 Write Ack Data The oscilloscope triggers on a read or write frame in 7 bit addressing mode on the 17th clock edge if all bits in the pattern match For triggering purposes a restart is treated as a start condition neac Write _ SDA N m a aera scL 1 7 8 8 B SINS Start or Address R Bok Data Rok Stop Pies Trigger point Condition 17th clock edge Frame Start Addr7 Read Ack Data Ack Data2 or Frame Start Addr7 Write Ack Data Ack Data2 The oscilloscope triggers on a read or write frame in 7 bit addressing mode on the 26th clock edge if all bits in the pattern match For triggering purposes a restart is treated as a s
48. accurately measure a signal is primarily determined by the signal s rise time not the signal s frequency You can use these steps to calculate the oscilloscope bandwidth required 1 Determine the fastest edge speeds You can usually obtain rise time information from published specifications for devices used in your designs 2 Compute the maximum practical frequency component From Dr Howard W Johnson s book High Speed Digital Design A Handbook of Black Magic all fast edges have an infinite spectrum of frequency components However there is an inflection or knee in the frequency spectrum of fast edges where frequency components higher than fknee are insignificant in determining the shape of the signal fknee 0 5 signal rise time based on 10 90 thresholds fknee 0 4 signal rise time based on 20 80 thresholds 3 Use a multiplication factor for the required accuracy to determine the oscilloscope bandwidth required Required accuracy Oscilloscope band wid th required 20 few 1 0 x fknee 10 few 1 3x fiee 3 few 1 9x tine Choosing an Oscilloscope with the Right Bandwidth for your Application Keysight Application Note 1588 http literature cdn keysight com litweb pdf 5989 5733EN pdf Memory Depth and Sample Rate The number of points of oscilloscope memory is fixed and there is a maximum sample rate associated with oscilloscope s analog to digital converter however the actual
49. be taken on an analog channel or math waveform Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 191 14 Measurements Changing default thresholds may change measurement results The default lower middle and upper threshold values are 10 50 and 90 of the value between Top and Base Changing these threshold definitions from the default values may change the returned measurement results for Average Delay Duty Cycle Fall Time Frequency Overshoot Period Phase Preshoot Rise Time Width and Width 1 From the Measurement Menu press the Settings softkey then press the Thresholds softkey to set analog channel measurement thresholds You can also open the Measurement Threshold Menu by pressing Analyze gt Features and then selecting Measurement Thresholds 2 Press the Source softkey to select the analog channel or math waveform source for which you want to change measurement thresholds Each analog channel and the math waveform can be assigned unique threshold values Measurement Thre Source 3 Press the Type softkey to set the measurement threshold to percentage of Top and Base value or to Absolute absolute value Percentage thresholds can be set from 5 to 95 The units for absolute threshold for each channel is set in the channel probe menu When the Source is set to Math f t the threshold Type can only be set to Percent TIP Absolute threshold hints Absolute threshold
50. data SDA line and the serial clock SCL line and then specifying the input signal threshold voltage levels To set up the oscilloscope to capture 1 C signals use the Signals softkey which appears in the Serial Decode Menu 1 Press Label to turn on labels 2 Press Serial KEYSIGHT TECHNOLOGIES 311 24 12C SPI Triggering and Serial Decode 3 Press the Mode softkey then select 12C trigger type 4 Press the Signals softkey to open the IC Signals Menu PC Signals Menu SCL Threshold Threshold 1 40V 1 40V 5 For both the SCL serial clock and SDA serial data signals a Connect an oscilloscope channel to the signal in the device under test b Press the SCL or SDA softkey then turn the Entry knob to select the channel for the signal c Press the corresponding Threshold softkey then turn the Entry knob to select the signal threshold voltage level The threshold voltage level is used in decoding and it will become the trigger level when the trigger type is set to the selected serial decode slot Data must be stable during the whole high clock cycle or it will be interpreted as a start or stop condition data transitioning while the clock is high The SCL and SDA labels for the source channels are automatically set I2C Triggering 312 To set up the oscilloscope to capture 12C signals see Setup for 12C Signals on page 311 After the oscilloscope has been set up to capture I2C signals you ca
51. digit channel number to D The indicates that two channels are overlaid To display digital channels as a bus Digital channels may be grouped and displayed as a bus with each bus value displayed at the bottom of the display in hex or binary You can create up to two buses To configure and display each bus press the Digital key on the front panel Then press the Bus softkey Digital Channel Menu D ttt ttttD om nm sf Channel Turn off Thresholds Bus v D7 DO mou lt Next select a bus Rotate the Entry knob then press the Entry knob or the Bus1 Bus2 softkey to switch it on Use the Channel softkey and the Entry knob to select individual channels to be included in the bus You can rotate the Entry knob and push it or push the softkey to select channels You can also press the Select Deselect D7 D0 softkey to include or exclude groups of eight channels in each bus Digital Bus Menu D ttt ttt2D Channel Deselect Base D7 DO Hex Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 91 Digital Channels Using cursors to read bus values If the bus display is blank completely white or if the display includes you need to expand the horizontal scale to allow space for the data to be shown or use the cursors to display the values see Using cursors to read bus values on page 92 The Base softkey lets you choose to display the bus values in hex or binary The buses are shown at t
52. displayed on the analog input channels including math functions Binary and Hex modes apply to digital signals of MSO oscilloscope models n Hex and Binary modes a level can be displayed as 1 higher than trigger evel O lower than trigger level indeterminate state 1 or X don t care n Binary mode X is displayed if the channel is turned off n Hex mode the channel is interpreted as 0 if turned off 4 Press Source or X1 Source X2 Source in the Track Waveform mode then select the input source for cursor values 5 Select the cursor s to be adjusted Push the Cursors knob then turn the Cursors knob To finalize your selection either push the Cursors knob again or wait about five seconds for the popup menu to disappear Or Press the Cursors softkey then turn the Entry knob The X1 X2 linked and Y1 Y2 linked selections let you adjust both cursors at the same time while the delta value remains the same This can be useful for example for checking pulse width variations in a pulse train The currently selected cursor s display brighter than the other cursors 6 Tochange the cursor units press the Units softkey In the Cursor Units Menu Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 167 168 13 Cursors Cursor Units Menu X Units Phase Use X Cursors Y Units As 360 ase You can press the X Units softkey to select Seconds s Hz 1 s Phase
53. displayed analog and digital channels Labels are displayed at the left edge of the displayed traces The figure below shows an example of displayed labels KEYSIGHT TECHNOLOGIES 113 9 Labels 2 05V KEYSIGHT TECHNOLOGIES Acquisition Channels ew labe l Channel Delete Apply New Library c Character Label ACK 2 To turn the labels off press the Label key again To assign a predefined label to a channel 1 Press the Label key 2 Press the Channel softkey then turn the Entry knob or successively press the Channel softkey to select a channel for label assignment 114 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Labels 9 2 05 KEYSIGHT TECHNOLOGIES Acquisition Channels Delete Apply New Library Character Label ACK The figure above shows the list of channels and their default labels The channel does not have to be turned on to have a label assigned to it 3 Press the Library softkey then turn the Entry knob or successively press the Library softkey to select a predefined label from the library 4 Press the Apply New Label softkey to assign the label to your selected channel 5 Repeat the above procedure for each predefined label you want to assign to a channel To define a new label 1 Press the Label key 2 Press the Channel softkey then turn the Entry knob or successively press the softkey to select a channel for label assignment The channel does
54. is enabled information about the selected signal sources and their threshold voltage levels as well as a waveform diagram appears on the screen 322 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide I2C SPI Triggering and Serial Decode 24 SPI Triggering To set up the oscilloscope to capture SPI signals see Setup for SPI Signals on page 319 After the oscilloscope has been set up to capture SPI signals you can then trigger on a data pattern that occurs at the start of a frame The serial data string can be specified to be from 4 to 32 bits long When you select the SPI trigger type and Display Info is enabled a graphic is displayed showing the current state of the frame signal clock slope number of data bits and data bit values 1 Press Trigger 2 Inthe Trigger Menu press the Trigger softkey then turn the Entry knob to select the serial slot Serial 1 on which the SPI signals are being decoded Trigger Menu Trigger Trigger Setup Display Info S SPI 3 Press the Trigger Setup softkey to open the SPI Trigger Setup Menu SPI Trigger Setup Menu Trigger HBits X Set all Bits Display Into MOSI Data 16 0 4 Press the Trigger softkey then turn the Entry knob to select the trigger condition Master Out Slave In MOSI Data for triggering on the MOSI data signal Master In Slave Out MISO Data for triggering on the MISO data signal 5 Press the Bits softkey and turn the Entr
55. like to view help Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 41 1 Getting Started Quick Help message To select the user interface and Quick Help language 42 KEYSIGH TEC Acquisition 12 Channels Fast Debug Channels Acq Mode All Normal Press and hold front panel key or softkey or right click softkey when using web browser remote front panel Quick Help remains on the screen until another key is pressed or a knob is turned To select the user interface and Quick Help language 1 Press Help then press the Language softkey 2 Repeatedly press and release the Language softkey or rotate the Entry knob until the desired language is selected The following languages are available English French German Italian Japanese Korean Portuguese Russian Simplified Chinese Spanish and Traditional Chinese Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls To adjust the horizontal time div scale 44 To adjust the horizontal delay position 45 Panning and Zooming Single or Stopped Acquisitions 46 To change the horizontal time mode Normal XY or Roll 46 To display the zoomed time base 50 To change the horizontal scale knob s coarse fine adjustment setting 51 To position the time reference left center right 52 Searching for Events 52 Navigating the Time
56. multiply V A or W Volt Amp FFT dB decibels See also FFT Units on page 75 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 67 4 Math Waveforms When the FFT source is channel 1 2 3 or 4 FFT units will be displayed in dBV when channel units is set to Volts and channel impedance is set to 1 MQ FFT units will be displayed in dBm when channel units is set to Volts and channel impedance is set to 50 FFT units will be displayed as dB for all other FFT sources or when a source channel s units has been set to Amps A scale unit of U undefined will be displayed for math functions when two source channels are used and they are set to dissimilar units and the combination of units cannot be resolved Math Operators Math operators perform arithmetic operations add subtract or multiply on analog input channels Add or Subtract on page 68 Multiply or Divide on page 69 Add or Subtract When you select add or subtract the Source 1 and Source 2 values are added or subtracted point by point and the result is displayed You can use subtract to make a differential measurement or to compare two waveforms If your waveforms DC offsets are larger than the dynamic range of the oscilloscope s input channels you will need to use a differential probe instead 68 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Math Waveforms 4 500 05 o 2 08V KEYSIGHT TECHNO
57. oscilloscope The oscilloscope must remain grounded through its power cord Defeating the ground creates an electric shock hazard Input a Waveform The first signal to input to the oscilloscope is the Demo 2 Probe Comp signal This signal is used for compensating probes 1 Connect an oscilloscope probe from channel 1 to the Demo 2 Probe Comp terminal on the front panel 2 Connect the probe s ground lead to the ground terminal next to the Demo 2 terminal Recall the Default Oscilloscope Setup To recall the default oscilloscope setup 1 Press Default Setup The default setup restores the oscilloscope s default settings This places the oscilloscope in a Known operating condition The major default settings are Table2 Default Configuration Settings Horizontal Normal mode 100 us div scale 0 s delay center time reference Vertical Analog Channel 1 on 5 V div scale DC coupling 0 V position Trigger Edge trigger Auto trigger mode 0 V level channel 1 source DC coupling rising edge slope 40 ns holdoff time Display Persistence off 20 grid intensity Other Acquire mode normal Run Stop to Run cursors and measurements off Labels All custom labels that you have created in the Label Library are preserved not erased but all channel labels will be set to their original names Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 27 1 Getting Started In th
58. packet frame Mid level blue lines show an idle bus The number of clocks in a frame appears in light blue above the frame to the right Decoded hexadecimal data values appear in white Decoded text is truncated at the end of the associated frame when there is insufficient space within frame boundaries Pink vertical bars indicate you need to expand the horizontal scale and run again to see decode Red dots in the decode line indicate that there is data that is not being displayed Scroll or expand the horizontal scale to view the information Aliased bus values undersampled or indeterminate are drawn in pink Unknown bus values undefined or error conditions are drawn in red Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide I2C SPI Triggering and Serial Decode 24 Interpreting SPI Lister Data 5 00 5 00 5 00 5 00 33 605 216 358 Stop SP 1 44 Time 9 872ms 7F EF 49 4C 45 4E 54 03 06 00 00 00 00 00 00 00 KEYSICHIT 6 590ms 06 5 850ms 05 FF 4 565ms FF FF FF 02 10 4D 53 4F gt FF 7F 7F 03 10 00 00 00 1 7 1ms 2 948ms FF 5 410ms E 03 20 00 MOSI FF FF FF 7F 7F Options w In addition to the standard Time column the SPI Lister contains these columns Data data bytes MOSI and MISO Aliased data is highlighted in pink When this happens decrease the horizontal time div setting and run again Searching for SPI Data in the Lister The oscilloscop
59. persistence see To set or clear persistence on page 109 clear the display and adjust the display grid graticule intensity see To adjust the grid intensity on page 111 14 File keys Press the Save Recall key to save or recall a waveform or setup See Chapter 18 Save Recall Setups Screens Data starting on page 223 The Print key opens the Print Configuration Menu so you can print the displayed waveforms See Chapter 19 Print Screens starting on page 235 15 Help key Opens the Help Menu where you can display overview help topics and select the Language See also Access the Built In Quick Help on page 41 16 Vertical controls The Vertical controls consist of Analog channel on off keys Use these keys to switch a channel on or off or to access a channel s menu in the softkeys There is one channel on off key for each analog channel Vertical scale knob There are knobs marked Ny N for each channel Use these knobs to change the vertical sensitivity gain of each analog channel Vertical position knobs Use these knobs to change a channel s vertical position on the display There is one Vertical Position control for each analog channel Label key Press this key to access the Label Menu which lets you enter labels to identify each trace on the oscilloscope display See Chapter 9 Labels starting on page 113 For more information
60. power supply N2782A Current probe 50 MHz 30 A AC DC use with N2779A power supply N2783A Current probe 100 MHz 30 A AC DC use with N2779A power supply Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 281 22 Reference Accessories Available In addition to passive proves Passive Probes on page 280 differential probes Differential Probes on page 281 and current probes Current Probes on page 281 the following accessories are available for the InfiniiVision 2000 X Series oscilloscopes Table 8 Accessories Available for InfiniiVision 2000 X Series Oscilloscopes Model Part Description DSOXLAN LAN VGA connection module DSOXGPIB GPIB connection module N6456A Rack mount kit N6457A Soft carrying case and front panel cover N2786A 2 leg probe positioner N2787A 3D probe positioner 1180CZ Testmobile N6458A Hardcopy user s guide various Front panel overlays see Front Panel Overlays for Different Languages on page 37 N6459 60001 8 channel logic probe and accessory kit standard with MSO models and with DSOX2MSO upgrade You can find these items at www keysight com or at Www parts keysight com Loading Licenses and Displaying License Information Licensed Options Available on page 283 Other Options Available on page 284 Upgrading to an MSO on page 284 282 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Gu
61. press Trig Out then turn the Entry knob to select from Triggers Each time the oscilloscope triggers a rising edge occurs on TRIG OUT The rising edge is delayed 30 ns from the oscilloscope s trigger point The output level is 0 5 V into an open circuit and 0 2 5 V into 50 Q See Chapter 10 Triggers starting on page 119 250 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Utility Settings 20 Mask The pass fail status is evaluated periodically When the evaluation of the testing period results in a failure the trigger output pulses high 5 V Otherwise the trigger output remains at low 0 V See Chapter 15 Mask Testing starting on page 195 Waveform Generator Sync Pulse All of the waveform generator output functions except DC and Noise have an associated Sync signal The Sync signal is a TTL positive pulse that occurs when the waveform rises above zero volts or the DC offset value See Chapter 17 Waveform Generator starting on page 211 The TRIG OUT connector also provides the User Cal signal See To perform user calibration on page 251 Performing Service Tasks The Service Menu under Utility gt Service lets you perform service related tasks Service Menu rt Hardware Front Panel User Cal Self Test Self Test To perform user calibration on page 251 To perform hard ware self test on page 254 To perform front panel self test on page 254 To di
62. probe leads and 1 pod ground lead qty 1 5959 9333 Replacement probe leads qty 5 also contains 01650 94309 probe labels 5959 9334 Replacement 2 inch probe grounds qty 5 5959 9335 Replacement pod ground leads qty 5 5090 4833 Grabbers qty 20 01650 94309 Package of probe labels For other replacement parts consult the nfiniiVision 2000 3000 X Series Oscilloscopes Service Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 99 6 Digital Channels 100 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Triggering on Serial Data Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Serial Decode Serial Decode Options 101 Lister 102 Searching Lister Data 104 Digital channels and serial decode cannot be on at the same time The Serial key takes precedence over the Digital key Serial triggers can be used when digital channels are on n some cases such as when triggering on a slow serial signal for example 12C SPI CAN LIN etc it may be necessary to switch from the Auto trigger mode to the Normal trigger mode to prevent the oscilloscope from Auto triggering and stabilize the display You can select the trigger mode by pressing the Mode Coupling key then the Mode softkey Also the threshold voltage level must be set appropriately for each source channel The threshold level for each serial signal can be set in the Signals Menu Press the Seria
63. see Chapter 3 Vertical Controls starting on page 57 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 35 1 36 Getting Started 17 Analog channel inputs Attach oscilloscope probes or BNC cables to these BNC connectors In the InfiniiVision 2000 X Series oscilloscopes the analog channel inputs have 1 MQ impedance Also there is no automatic probe detection so you must properly set the probe attenuation for accurate measurement results See To specify the probe attenuation on page 62 18 Demo 2 Ground and Demo 1 terminals Demo 2 terminal This terminal outputs the Probe Comp signal which helps you match a probe s input capacitance to the oscilloscope channel to which it is connected See Compensate Passive Probes on page 29 With certain licensed features the oscilloscope can also output demo or training signals on this terminal Ground terminal Use the ground terminal for oscilloscope probes connected to the Demo 1 or Demo 2 terminals Demo 1 terminal With certain licensed features the oscilloscope can output demo or training signals on this terminal 19 USB Host port This port is for connecting USB mass storage devices or printers to the oscilloscope Connect a USB compliant mass storage device flash drive disk drive etc to save or recall oscilloscope setup files and reference waveforms or to save data and screen images See Chapte
64. set to Video Video trigger mode is set to All Lines Display Grid type is set to IRE when Standard is NTSC or mV see To select the grid type on page 110 Horizontal time division is set to 10 us div for NTSC PAL SECAM standards Horizontal delay is set so that trigger is at first horizontal division from the left You can also press Analyze gt Features and then select Video to quickly access the video triggering automatic set up and display options 8 Press the Mode softkey to select the portion of the video signal that you would like to trigger on The Video trigger modes available are Field1 and Field2 Trigger on the rising edge of the first serration pulse of field 1 or field 2 interlaced standards only All Fields Trigger on the rising edge of the first pulse in the vertical sync interval All Lines Trigger on all horizontal sync pulses Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 131 10 Triggers Video Triggering Examples To trigger on a specific line of video 132 Line Field1 and Line Field2 Trigger on the selected line in field 1 or field 2 interlaced standards only Line Alternate Alternately trigger on the selected line in field 1 and field 2 NTSC PAL PAL M and SECAM only 9 If you select a line mode press the Line softkey then rotate the Entry knob to select the line number on which you want to trigger The following table lists
65. softkey press the Function sofkey and select f t Displayed 3 Use the Operator softkey to select an operator or transform For more information on the operators or transforms see Math Operators on page 68 Math Transforms on page 70 4 Use the Source 1 softkey to select the analog channel on which to perform math You can rotate the Entry knob or repetitively press the Source 1 softkey to make your selection If you choose a transform function FFT the result is displayed 5 If you select an arithmetic operator use the Source 2 softkey to select the second source for the arithmetic operation The result is displayed 6 To re size and re position the math waveform see To adjust the math waveform scale and offset on page 67 Math Operating Hints If the analog channel or math function is clipped not fully displayed on screen the resulting displayed math function will also be clipped Once the function is displayed the analog channel s may be turned off for better viewing of the math waveform The vertical scaling and offset of each math function can be adjusted for ease of viewing and measurement considerations The math function waveform can be measured using Cursors and or Meas To perform a transform function on an arithmetic operation 66 To perform a transform function FFT on an arithmetic operation add subtract or multiply 1 Press the Function softkey and select g t Internal 2 Us
66. the bit s time where the bit value is captured y One Bit X Press the Signal softkey and select the type and polarity of the CAN signal This also automatically sets the channel label for the source channel CAN_H The actual CAN_H differential bus Differential H L The CAN differential bus signals connected to an analog source channel using a differential probe Connect the probe s positive lead to the dominant high CAN signal CAN_H and connect the negative lead to the dominant low CAN signal CAN_L Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide CAN LIN Triggering and Serial Decode 23 Dominant low signals Rx The Receive signal from the CAN bus transceiver Tx The Transmit signal from the CAN bus transceiver CAN_L The actual CAN_L differential bus signal Differential L H The CAN differential bus signals connected to an analog source channel using a differential probe Connect the probe s positive lead to the dominant low CAN signal CAN_L and connect the negative lead to the dominant high CAN signal CAN_H CAN Triggering To set up the oscilloscope to capture a CAN signal see Setup for CAN Signals on page 295 The Controller Area Network CAN trigger allows triggering on CAN version 2 0A and 2 0B signals A CAN message frame in CAN_L signal type is shown below Field Field Field Field Field Bus Arbitration Control Data CRC ACK EOF Intermission Idl
67. the middle threshold points of two consecutive like polarity edges A middle threshold crossing must also travel through the lower and upper threshold levels which eliminates runt pulses The X cursors show what portion of the waveform is being measured The Y cursor shows the middle threshold point 186 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Measurements 14 Frequency Frequency is defined as 1 Period Period is defined as the time between the middle threshold crossings of two consecutive like polarity edges A middle threshold crossing must also travel through the lower and upper threshold levels which eliminates runt pulses The X cursors show what portion of the waveform is being measured The Y cursor shows the middle threshold point See Also To isolate an event for frequency measurement on page 187 To isolate an event for frequency measurement The following figure shows how to use Zoom mode to isolate an event for a frequency measurement You may need to change the measurement window setting so that the measurement is made in the lower Zoom window See Measurement Window with Zoom Display on page 193 If the waveform is clipped it may not be possible to make the measurement 50 008 1 00027 Channels x Measurements Measurement Menu Source Settings Clear Meas ap 5 Figure 35 Isolating an event for Frequency measurement Keysight InfiniiVision 2000 X Series Oscilloscopes U
68. triggers can be used when digital channels are on Multiplexed scale knob This scale knob is used with Math Ref or Digital waveforms whichever has the illuminated arrow to the left For math and reference waveforms the scale knob acts like an analog channel vertical scale knob Multiplexed position knob This position knob is used with Math Ref or Digital waveforms whichever has the illuminated arrow to the left For math and reference waveforms the position knob acts like an analog channel vertical position knob Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Getting Started 1 12 Measure controls The measure controls consist of Cursors knob Push this knob select cursors from a popup menu Then after the popup menu closes either by timeout or by pushing the knob again rotate the knob to adjust the selected cursor position Cursors key Press this key to open a menu that lets you select the cursors mode and source Meas key Press this key to access a set of predefined measurements See Chapter 14 Measurements starting on page 175 13 Waveform keys The Acquire key lets you select Normal Peak Detect Averaging or High Resolution acquisition modes see Selecting the Acquisition Mode on page 155 and use segmented memory see Acquiring to Segmented Memory on page 161 The Display key lets you access the menu where you can enable
69. 0 1 Press the Digital key so that the Digital Channel Menu is displayed 2 Press the Thresholds softkey 3 Press the D7 DO softkey then select a logic family preset or select User to define your own threshold Logic family Threshold Voltage TTL 1 4 V CMOS 2 5 V ECL 1 3 V User Variable from 8 V to 8 V The threshold you set applies to all channels within the selected D7 DO group Each of the two channel groups can be set to a different threshold if desired Values greater than the set threshold are high 1 and values less than the set threshold are low 0 If the Thresholds softkey is set to User press the User softkey for the channel group then turn the Entry knob to set the logic threshold There is one User softkey for each group of channels Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Digital Channels 6 To reposition a digital channel 1 Make sure the multiplexed scale and position knobs to the right of the key are selected for digital channels f the arrow to the left of the Digital key is not illuminated press the key 2 Use the multiplexed Select knob to select the channel The selected waveform is highlighted in red 3 Use the multiplexed Position knob to move the selected channel waveform f a channel waveform is repositioned over another channel waveform the indicator at the left edge of the trace will change from Dnn designation where nn is a one or two
70. 0 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference Specifications and Characteristics 277 Measurement Category 277 Environmental Conditions 279 Probes and Accessories 279 Loading Licenses and Displaying License Information 282 Software and Firmware Updates 284 Binary Data bin Format 284 CSV and ASCII XY files 291 Acknowledgements 293 Specifications and Characteristics Please see the InfiniiVision oscilloscope data sheets for complete up to date specifications and characteristics To download a data sheet please visit www keysight com find 2000X Series Then select the Library tab followed by Specifications Or go to the Keysight home page at www keysight com and search for 2000 X Series oscilloscopes data sheet To order a data sheet by phone please contact your local Keysight office The complete list is available at www keysight com find contactus or on To contact Keysight on page 255 Measurement Category Oscilloscope Measurement Category on page 278 Measurement Category Definitions on page 278 KEYSIGHT TECHNOLOGIES 277 22 Reference Transient Withstand Capability on page 278 Oscilloscope Measurement Category The InfiniiVision oscilloscopes are intended to be used for measurements in Measurement Category WARNING Use this instrument only for measurements within its specified measu
71. 15 b 2 November 1995 as applicable in any tech nical data Safety Notices CAUTION A CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met A WARNING notice denotes a haz ard It calls attention to an operat ing procedure practice or the like that if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide InfiniiVision 2000 X Series Oscilloscopes At a Glance AW KEYSIGHT InfiniVision MSO X 2024A Mans Spal Onitonuye mommu sosar MER Z oom ana WO B Al i By Ol u 0 m ta O E y Table 1 2000 X Series Model Numbers Band widths Bandwidth 70 MHz 100 MHz 200 MHz 2 Channel 8 Logic MSO X 2002A MSO X 2012A MSO X 2022A Channels MSO 4 Channel 8 Logic MSO X 2004A MSO X 2014A MSO X 2024A Channels MSO 2 Channel DSO DSO X 2002A DSO X 2012A DSO X 2022A 4 Channel DSO DSO X 2004A DSO X 2014A DSO X 2024A The Keysight InfiniiVision 2000 X Series oscilloscopes deliver these features 70 MHz 100 MHz
72. 18 You can use a connected USB keyboard instead of using the Spell and other character editing softkeys When available the Increment softkey can be used to enable or disable automatically incremented file names Auto increment adds a numeric suffix to your file name and increments the number with each successive save It will truncate characters as necessary when the file name length is at maximum and more digits are required for the numeric portion of the file name Recalling Setups Masks or Reference Waveforms 1 Press the Save Recall key 2 Inthe Save Recall Menu press Recall 3 In the Recall Menu press Recall then turn the Entry knob to select the type of file you want to recall Setup scp See To recall setup files on page 231 Mask msk See To recall mask files on page 232 Reference Waveform data h5 See To recall reference waveform files from a USB storage device on page 232 You can also recall setups and mask files by loading them using the File Explorer See File Explorer on page 245 You can also configure the Quick Action key to recall setups masks or reference waveforms See Configuring the Quick Action Key on page 256 To recall setup files Setup files can be recalled from one of 10 internal Keysight Flash locations or from an external USB storage device 1 Press Save Recall gt Recall gt Recall then turn the Entry knob to select Setup scp
73. 2 50 0 500 02 50 0 500 05 00 1 000 02 50 1 500 02 50 1 500 Region Number 4 Number of vertices 5 10 00 1 000 12 50 0 500 15 00 0 500 15 00 1 500 12 50 1 500 Region Number 5 Number of vertices 5 10 00 1 000 12 50 0 500 15 00 0 500 15 00 1 500 12 50 1 500 Region Number 6 Number of vertices 6 05 00 1 000 02 50 0 500 02 50 0 500 05 00 1 000 02 50 1 500 02 50 1 500 Region Number 7 Number of vertices 5 10 00 1 000 12 50 0 500 15 00 0 500 15 00 1 500 12 50 1 500 Region Number 8 Number of vertices 4 12 50 MIN 10 00 1 750 10 00 1 750 12 50 MIN setup MTES ENAB 1 CHAN1 RANG 4 00E 00 OFFS 0 0E 00 COUP DC IMP ONEM DISP 1 BWL 0 INV 0 CHAN1 LAB 1 UNIT VOLT PROB 1 0E 00 PROB SKEW 0 0E 00 STYP SING CHAN2 RANG 16 0E 00 OFFS 1 62400E 00 COUP DC IMP FIFT DISP 0 BWL 0 INV 0 CHAN2 LAB 2 UNIT VOLT PROB 1 0E 00 PROB SKEW 0 0E 00 STYP SING Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 205 15 Mask Testing CHAN3 RANG 40 0E 00 OFFS 0 0E 00 COUP DC IMP ONEM DISP 0 BWL 0 INV 0 CHAN3 LAB 3 UNIT VOLT PROB 1 0E 00 PROB SKEW 0 0E 00 STYP SING CHAN4 RANG 40 0E 00 OFFS 0 0E 00 COUP DC IMP ONEM DISP 0 BWL 0 INV 0 CHAN4 LAB 4 UNIT VOLT PROB 1 0E 00 PROB SKEW 0 0E 00 STYP SING EXT BWL 0 IMP ONEM RANG 5E 00 UNIT VOLT PROB 1 0E 00 PROB STYP SING T
74. 312 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Index identification function web interface 272 idle serial bus 300 308 317 326 334 impedance digital probes 94 indeterminate state 167 infinite persistence 109 150 156 information area 41 installed licenses 254 installed options 272 Instrument Utilities web page 272 intensity control 107 Intensity key 31 invert graticule colors 225 invert waveform 61 IP address 243 261 Italian front panel overlays 38 Italian user interface and Quick Help 42 J Japanese front panel overlays 38 Japanese user interface and Quick Help 42 K keyboard USB 116 231 237 248 258 keys front panel 30 Keysight I0 Libraries Suite 268 knobs front panel 30 Korean front panel overlays 38 Korean user interface and Quick Help 42 L Label key 35 label list 117 label list loading from text file 116 labels 113 labels auto increment 116 labels default library 117 LAN connection 243 LAN interface remote control 241 LAN port 39 LAN Settings softkey 243 244 341 Index LAN VGA module 24 39 LAN VGA module installation 24 landscape mode 238 language user interface and Quick Help 42 length control 227 length softkey 227 level trigger 120 LF Reject 144 library labels 115 licenses 283 284 LIN serial decode 306 LIN trigger 305 line voltage 25 Lister 102 load file 245
75. 4 Math Waveforms starting on page 65 Ref key provides access to reference waveform functions Reference waveforms are saved waveforms that can be displayed and compared against other analog channel or math waveforms See Chapter 5 Reference Waveforms starting on page 79 Digital key Press this key to turn the digital channels on or off the arrow to the left will illuminate When the arrow to the left of the Digital key is illuminated the upper multiplexed knob selects and highlights in red individual digital channels and the lower multiplexed knob positions the selected digital channel If a trace is repositioned over an existing trace the indicator at the left edge of the trace will change from Dn designation where n is a one digit channel number from 0 to 7 to D The indicates that two channels are overlaid You can rotate the upper knob to select an overlaid channel then rotate the lower knob to position it just as you would any other channel For more information on digital channels see Chapter 6 Digital Channels starting on page 83 Serial key This key is used to enable serial decode The multiplexed scale and position knobs are not used with serial decode For more information on serial decode see Chapter 7 Serial Decode starting on page 101 Digital channels and serial decode cannot be on at the same time The Serial key takes precedence over the Digital key Serial
76. 4 Measurements starting on page 175 Chapter 15 Mask Testing starting on page 195 Chapter 16 Digital Voltmeter starting on page 207 When using the built in waveform generator see Chapter 17 Waveform Generator starting on page 211 When saving recalling or printing see Chapter 18 Save Recall Setups Screens Data starting on page 223 Chapter 19 Print Screens starting on page 235 When using the oscilloscope s utility functions or web interface see For reference information see When using licensed serial bus triggering and decode features see Chapter 20 Utility Settings starting on page 241 Chapter 21 Web Interface starting on page 261 Chapter 22 Reference starting on page 277 Chapter 23 CAN LIN Triggering and Serial Decode starting on page 295 Chapter 24 I2C SPI Triggering and Serial Decode starting on page 311 Chapter 25 UART RS232 Triggering and Serial Decode starting on page 329 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Abbreviated instructions for pressing a series of keys and softkeys Instructions for pressing a series of keys are written in an abbreviated manner Instructions for pressing Key1 then pressing Softkey2 then pressing Softkey3 are abbreviated as follows Press Key1 gt Softkey2 gt Softkey3 The keys may be a front panel Key or a Softkey
77. 7 Quick Freeze Display 257 Quick Help 41 Quick Help language 42 Quick Measure All 256 Quick Print 256 Quick Recall 256 Quick Save 256 Quick Trigger Mode 257 R ramp waveform generator output 213 random noise 141 ratio X cursor units 168 ratio Y cursor units 168 raw acquisition record 227 Real Scope Remote Front Panel 264 rear panel connectors 38 re arm time 163 recall 256 recall files via web interface 270 recall mask files 232 recall setups 231 recall Quick Recall 256 Rectangular FFT window 72 Ref key 34 79 reference point waveform 247 reference waveforms 79 remote control 241 Remote Front Panel 267 remote programming Keysight I0 Libraries 268 remote programming web interface 267 replacement parts 98 required oscilloscope bandwidth 154 reset network password 276 restart condition 12C trigger 313 return instrument for service 255 Rise time measurement 188 rise time oscilloscope 153 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Index rise time signal 154 roll mode 47 RS232 trigger 331 Run Control keys 33 runt pulses 186 Russian front panel overlays 38 Russian user interface and Quick Help 42 S safety warning 27 sample rate 4 sample rate and memory depth 154 sample rate current rate displayed 44 sample rate oscilloscope 152 153 sampling theory 151 sampling overview 150 save 256 save file 245 save files via
78. 78 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 5 Reference Waveforms To save a waveform to a reference waveform location 79 To display a reference waveform 80 To scale and position reference waveforms 81 To adjust reference waveform skew 81 To display reference waveform information 82 To save recall reference waveform files to from a USB storage device 82 Analog channel or math waveforms can be saved to one of two reference waveform locations in the oscilloscope Then a reference waveform can be displayed and compared against other waveforms One reference waveform can be displayed at a time When the multiplexed knobs are assigned to reference waveforms this happens when you press the Ref key and the LED to the left of it is lit you can use the knobs to scale and position reference waveforms There is also a skew adjustment for reference waveforms Reference waveform scale offset and skew information can optionally be included on the oscilloscope display Analog channel math or reference waveforms can be saved to a reference waveform file on a USB storage device You can recall a reference waveform file from a USB storage device into one of the reference waveform locations To save a waveform to a reference waveform location 1 Press the Ref key to turn on reference waveforms 2 Inthe Reference Waveform Menu press the Ref
79. 99 65Hz Pk Pk 1 Delay 14 24 191 0us Measurement Menu Source Add Settings Clear Meas Measurement lt gt Phase Phase is the calculated phase shift from source 1 to source 2 expressed in degrees Negative phase shift values indicate that the rising edge of source 1 occurred after the rising edge of source 2 B Delay Phase Source Period 360 i4 Period gt Source 1 _ fy ff S gt Delay Source 2 NO A No O A o 1 Press the Meas key to display the Measurement Menu 2 Press the Source softkey then turn the Entry knob to select the first analog channel source 3 Press the Type softkey then turn the Entry knob to select Delay 190 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Measurements 14 4 Press the Settings softkey to select the second analog channel source for the phase measurement The default Phase settings measure from channel 1 to channel 2 5 Press the S Back Up key to return to the Measurement Menu 6 Press the Add Measurement softkey to make the measurement The example below shows a phase measurement between the channel 1 and the math d dt function on channel 1 Channels x Measurements Freq 1 499 15Hz Pk Pk 1 Delay 14 gt Phase 1 gt 35 9 Measurement Menu Source Type Add Settings Clear Meas Phase Measurement gt Measurement Thresholds Setting measurement thresholds defines the vertical levels where measurements will
80. A B Passive probe 10 1 150 MHz 1 2 m N2863A B Passive probe 10 1 300 MHz 1 2 m N2889A Passive probe 10 1 1 1 350 MHz 1 2 m N2890A Passive probe 10 1 500 MHz 1 2 m 280 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Reference 22 Differential Probes The following differential probes can be used with the InfiniiVision 2000 X Series oscilloscopes Table 6 Differential Probes Model Description 1141A Active differential probe 200 MHz 200 VDC peak AC max requires 1142A power supply 1144A Active probe 800 MHz requires 1142A power supply 1145A Active probe 750 MHz 2 ch requires 1142A power supply N2772A Active differential probe 20 MHz 1 2 kVDC peak AC max requires N2773A power supply N2791A High voltage differential probe 25 MHz 700 V 1 MOhm termination 10 1 or 100 1 switchable N2792A Differential probe 200 MHz 10 1 50 Ohm termination N2793A Differential probe 800 MHz 10 1 15 V 50 Ohm termination Current Probes The following current probes can be used with the InfiniiVision 2000 X Series oscilloscopes Table 7 Current Probes Model Description 1146A Current probe 100 kHz 100 A AC DC N2774A Obsolete replaced by N2782A with N2775A power supply N2780A Current probe 2 MHz 500 A AC DC use with N2779A power supply N2781A Current probe 10 MHz 150 A AC DC use with N2779A
81. Address Subnet Mask Gateway IP and DNS IP values When you are done go back up in the menu hierarchy c Press the Host name softkey Use the softkeys and the Entry knob to enter the Host name When you are done go back up in the menu hierarchy d Press the Apply softkey Connect the oscilloscope to the local area network LAN by inserting the LAN cable into the LAN port on the rear panel of the oscilloscope Stand alone Point to Point Connection to a PC The following procedure describes how to establish a point to point stand alone connection to the oscilloscope This is useful if you want to control the oscilloscope using a laptop computer or a stand alone computer 1 2 3 Press Utility gt 1 0 Press the LAN Settings softkey Press the Config softkey then turn the Entry knob to select Automatic and press the softkey again to enable it If your network supports DHCP or AutolP enabling Automatic lets the oscilloscope use those services to get its LAN configuration settings Connect your PC to the oscilloscope using a cross over LAN cable such as Keysight part number 5061 0701 available on the web at www parts keysight com Cycle power on the oscilloscope Wait until the LAN connection is configured Press Utility gt 1 0 and wait until the LAN status shows configured This may take a few minutes Now the instrument is connected and the instrument s web interface or remote control via LAN may b
82. Decibels or V RMS as the units for the FFT vertical scale Auto Setup sets the frequency Span and Center to values that will cause the entire available spectrum to be displayed The maximum available frequency is half the FFT sample rate which is a function of the time per division setting The FFT resolution is the quotient of the sampling rate and the number of FFT points fs N The current FFT Resolution is displayed above the softkeys Scale and offset considerations If you do not manually change the FFT scale or offset settings when you turn the horizontal scale knob the span and center frequency settings will automatically change to allow optimum viewing of the full spectrum If you do manually set scale or offset turning the horizontal scale knob will not change the span or center frequency settings allowing you see better detail around a specific frequency Pressing the FFT Auto Setup softkey will automatically rescale the waveform and span and center will again automatically track the horizontal scale setting 3 To make cursor measurements press the Cursors key and set the Source softkey to Math f t Use the X1 and X2 cursors to measure frequency values and difference between two frequency values AX Use the Y1 and Y2 cursors to measure amplitude in dB and difference in amplitude AY Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Math Waveforms 4 4 To make other measurements press the
83. IES Acquisition Channels m Math Menu f t Ch1 Ch2 i Operator Source 1 Source 2 Figure 5 Example of Subtract Channel 2 from Channel 1 See Also Units for Math Waveforms on page 67 Multiply or Divide When you select the multiply or divide math function the Source 1 and Source 2 values are multiplied or divided point by point and the result is displayed The divide by zero case places holes that is zero values in the output waveform Multiply is useful for seeing power relationships when one of the channels is proportional to the current Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 69 4 Math Waveforms 500 05 o 2 08V KEYSIGHT TECHNO IES Acquisition Channels m Math Menu f t Ch1 Ch2 Operator Source 1 Source 2 Figure 6 Example of Multiply Channel 1 by Channel 2 See Also Units for Math Waveforms on page 67 Math Transforms Math transforms perform a transform function FFT on an analog input channel or on the result of an arithmetic operation FFT Measurement on page 70 Measurement FFT is used to compute the fast Fourier transform using analog input channels or an arithmetic operation g t FFT takes the digitized time record of the specified source and transforms it to the frequency domain When the FFT function is selected the FFT spectrum is plotted on the oscilloscope display as magnitude in dBV versus frequency The readout for the ho
84. IM MODE MAIN REF CENT MAIN RANG 50 00E 09 POS 0 0E 00 TRIG MODE EDGE SWE AUTO NREJ 0 HFR 0 HOLD 60E 09 TRIG EDGE SOUR CHAN1 LEV 75 00E 03 SLOP POS REJ OFF COUP DC ACQ MODE RTIM TYPE NORM COMP 100 COUNT 8 SEGM COUN 2 DISP LAB 0 CONN 1 PERS MIN SOUR PMEM1 HARD APR AREA SCR FACT 0 FFE 0 INKS 1 PAL NONE LAY PORT SAVE FIL mask_0 SAVE IMAG AREA GRAT FACT 0 FORM NONE INKS 0 PAL COL SAVE WAV FORM NONE MTES SOUR CHAN1 ENAB 1 LOCK 1 MTES AMAS SOUR CHAN1 UNIT DIV XDEL 3 00000000E 001 YDEL 2 00000000E 00 1 MTES SCAL BIND 0 X1 0 0E 00 XDEL 1 0000E 09 Y1 0 0E 00 Y2 1 00000E 0 0 MTES RMOD FOR RMOD TIME 1E 00 WAV 1000 SIGM 6 0E 00 MTES RMOD FACT STOP 0 PRIN 0 SAVE 0 end_setup How is mask testing done 206 InfiniiVision oscilloscopes start mask testing by creating a database that is 200 x 640 for the waveform viewing area Each location in the array is designated as either a violation or a pass area Each time a data point from a waveform occurs in a violation area a failure is logged If Test All was selected every active analog channel is tested against the mask database for each acquisition Over 2 billion failures can be logged per channel The number of acquisitions tested is also logged and displayed as of Tests The mask file allows greater resolution than the 200 X 640 database Some quantization of data occurs to reduce the mask file data for display on screen Keysight InfiniiVision
85. Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide KEYSIGHT TECHNOLOGIES Notices Keysight Technologies Inc 2005 2013 No part of this manual may be reproduced in any form or by any means including elec tronic storage and retrieval or translation into a foreign language without prior agreement and written consent from Keysight Technolo gies Inc as governed by United States and international copyright laws Manual Part Number 75015 97045 Edition Sixth edition April 2013 Printed in Malaysia Published by Keysight Technologies Inc 1900 Garden of the Gods Road Colorado Springs CO 80907 USA Print History 75015 97000 January 2011 75015 97011 February 2011 75015 97012 June 2011 75015 97023 March 2012 75015 97034 July 2012 75015 97045 April 2013 Trademarks Java is a U S trademark of Sun Microsys tems Inc Sun Sun Microsystems and the Sun Logo are trademarks or registered trademarks of Sun Microsystems Inc in the U S and other countries Warranty The material contained in this docu ment is provided as is and is subject to being changed without notice in future editions Further to the maxi mum extent permitted by applicable law Keysight disclaims all warranties either express or implied with regard to this manual and any information con tained herein including but not limited to the implied warranties of merchant ability and fitness for a pa
86. Menu press the Trigger softkey then turn the Entry knob to select Pulse Width Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Triggers 10 KEYSIGHT TECHN S Acquisition Channels Source 5 00us 3 Press the Source softkey then rotate the Entry knob to select a channel source for the trigger The channel you select is shown in the upper right corner of the display next to the polarity symbol The source can be any analog or digital channel available on your oscilloscope 4 Adjust the trigger level For analog channels turn the Trigger Level knob For digital channels press the Digital key and select Thresholds to set the threshold level The value of the trigger level or digital threshold is displayed in the upper right corner of the display Press the pulse polarity softkey to select positive JL or negative LJ polarity for the pulse width you want to capture ol The selected pulse polarity is displayed in the upper right corner of the display A positive pulse is higher than the current trigger level or threshold and a negative pulse is lower than the current trigger level or threshold Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 127 10 Triggers Pulse width trigger lt qualifier time set softkey 128 When triggering on a positive pulse the trigger will occur on the high to low transition of the pulse if the qualifying condition is true When triggering on a
87. P upgrade Setup for UART RS232 Signals To set up the oscilloscope to capture UART RS232 signals 1 Press Label to turn on labels 2 Press Serial 3 Press the Mode softkey then select UART RS232 trigger type 4 Press the Signals softkey to open the UART RS232 Signals Menu signals Menu Threshold 1 12 KEYSIGHT TECHNOLOGIES 329 25 UART RS232 Triggering and Serial Decode 5 For both the Rx and Tx signals a Connect an oscilloscope channel to the signal in the device under test b Press the Rx or Tx softkey then turn the Entry knob to select the channel for the signal c Press the corresponding Threshold softkey then turn the Entry knob to select the signal threshold voltage level The threshold voltage level is used in decoding and it will become the trigger level when the trigger type is set to the selected serial decode slot The RX and TX labels for the source channels are automatically set 6 Press the O Back Up key to return to the Serial Decode Menu 7 Press the Bus Config softkey to open the UART RS232 Bus Configuration Menu 3us Configuration Menu Parity Baud Rate Polarity Bit Order LSB Odd E S Idle low Set the following parameters a Bits Set the number of bits in the UART RS232 words to match your device under test selectable from 5 9 bits b Parity Choose odd even or none based on your device under test c Baud Press the Baud Rate softkey then press the Baud softk
88. Single key you can press the Scroll Lister softkey and then rotate the Entry knob to select an event and press the Zoom to Selection softkey to jump to the event To use the Lister 1 Set up trigger and decode on the serial data signals to be analyzed 2 Press Serial gt Lister 3 Press Display then turn the Entry knob to select the serial slot Serial 1 on which the serial bus signals are being decoded Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Serial Decode 7 1 12V KEYSIGHT TECHNOLOGIES Lister Menu Display Zoom to Options S UART AS232 Selection v Before you can select a row or navigate through the Lister data oscilloscope acquisitions must be stopped 4 Press the Single key in the Run Control group on the front panel to stop the acquisition Pressing Single instead of Stop fills the maximum memory depth When zoomed out and viewing a large number of packets the Lister may not be able to display information for all packets However when you press the Single key the Lister will contain all on screen serial decode information 5 Press the Scroll Lister softkey and use the Entry knob to scroll through the data Time tags in the Time column indicate the event time relative to the trigger point The time tags of events that are shown in the waveform display area are displayed with a dark background 6 Press the Zoom to Selection softkey
89. Softkeys are the six keys located directly below the oscilloscope display Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide InfiniiVision 2000 X Series Oscilloscopes At a Glance 3 In This Guide 5 Inspect the Package Contents 21 Install the Optional LAN VGA or GPIB Module 24 Tilt the Oscilloscope for Easy Viewing 24 Power On the Oscilloscope 25 Connect Probes to the Oscilloscope 26 A Maximum input voltage at analog inputs 26 Do not float the oscilloscope chassis 26 Input a Waveform 27 Recall the Default Oscilloscope Setup 27 Use Auto Scale 28 Compensate Passive Probes 29 Learn the Front Panel Controls and Connectors 30 Front Panel Overlays for Different Languages 37 Learn the Rear Panel Connectors 38 Learn the Oscilloscope Display 40 Access the Built In Quick Help 41 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls To adjust the horizontal time div scale 44 To adjust the horizontal delay position 45 Panning and Zooming Single or Stopped Acquisitions 46 To change the horizontal time mode Normal XY or Roll 46 XY Time Mode 47 To display the zoomed time base 50 To change the horizontal scale knob s coarse fine adjustment setting 51 To position the time reference left center right 52 Searching for Events 52 To setup searches 53 Navigating the Time Base 53 To navigate time 53 To navi
90. T RS232 Press the Trigger Setup softkey to open the UART RS232 Trigger Setup Menu 232 Trigger Setup Menu Trigger Data is Tx Data Press the Base softkey to select Hex or ASCII as the base displayed on the Data softkey in the UART RS232 Trigger Setup Menu Note that the setting of this softkey does not affect the selected base of the decode display Press the Trigger softkey and set up the desired trigger condition Rx Start Bit The oscilloscope triggers when a start bit occurs on Rx Rx Stop Bit Triggers when a stop bit occurs on Rx The trigger will occur on the first stop bit This is done automatically whether the device under test uses 1 1 5 or 2 stop bits You do not need to specify the number of stop bits used by the device Under test Rx Data Triggers on a data byte that you specify For use when the device under test data words are from 5 to 8 bits in length no 9th alert bit Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 331 25 UART RS232 Triggering and Serial Decode 332 Rx 1 Data For use when length including the alert bit is 1 The specified data byte applies to the least significant 8 bi excludes the 9th alert bit Rx 0 Data For use when the device under test da the device under test da ta words are 9 bits in bit the 9th bit Triggers only when the 9th alert oo US ta words are 9 bits in length including the alert bit the 9th
91. Time 2010 10 22 Segmented Current Seg of Segs 5 25 J Saving Data from Segmented Memory You can save either the currently displayed segment Save Segment Current or all segments Save Segment All in the following data formats CSV ASCII XY and BIN Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 163 12 Acquisition Control Be sure to set the Length control to capture enough points to accurately represent the captured data When the oscilloscope is busy saving multiple segments progress is displayed in the upper right area of the display For more information see To save CSV ASCII XY or BIN data files on page 226 164 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors To make cursor measurements 166 Cursor Examples 169 Cursors are horizontal and vertical markers that indicate X axis values and Y axis values on a selected waveform source You can use cursors to make custom voltage time phase or ratio measurements on oscilloscope signals Cursor information is displayed in the right side information area Cursors are not always limited to the visible display If you set a cursor then pan and zoom the waveform until the cursor is off screen its value will not be changed It will still be there when you return to its original location X Cursors X cursors are vertical dashed lines that adju
92. Triggers starting on page 119 and Chapter 11 Trigger Mode Coupling starting on page 141 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Getting Started 1 7 Horizontal controls The Horizontal controls consist of Horizontal scale knob Turn the knob in the Horizontal section that is marked N to adjust the time div sweep speed setting The symbols under the knob indicate that this control has the effect of spreading out or zooming in on the waveform using the horizontal scale Horizontal position knob Turn the knob marked lt to pan through the waveform data horizontally You can see the captured waveform before the trigger turn the knob clockwise or after the trigger turn the knob counterclockwise If you pan through the waveform when the oscilloscope is stopped not in Run mode then you are looking at the waveform data from the last acquisition taken Horiz key Press this key to open the Horizontal Menu where you can select XY and Roll modes enable or disable Zoom enable or disable horizontal time division fine adjustment and select the trigger time reference point Zoom key Press the zoom key to split the oscilloscope display into Normal and Zoom sections without opening the Horizontal Menu Search key Lets you search for events in the acquired data Navigate keys Press this key to navigate through captured data Time search
93. UT EXT me cat ie 6 EXT TRIG IN connector 2 5 Calibration protect button 3 GPIB 4 TRIG OUT connector Nl WARNING MAIN TAIN GROUND TO AVOID ELECTRIC SHOCK 3 Module slot 100 120V S0 60 400H2 ia aeoe 2 Kensington lock hole Ph 1 Power cord connector 1 Power cord Attach the power cord here connector 2 Kensington lock This is where you can attach a Kensington lock for securing the instrument hole 3 Module slot No modules are included with the oscilloscope A DSOXLAN LAN VGA module may be ordered and installed separately LAN port lets you communicate with the oscilloscope and use the Remote Front Panel feature using the LAN port See Chapter 21 Web Interface starting on page 261 and Accessing the Web Interface on page 262 VGA video output lets you connect an external monitor or projector to provide a larger display or to provide a display at a viewing position away from the oscilloscope The oscilloscope s built in display remains on even when an external display is connected The video output connector is always active For optimal video quality and performance we recommend you use a shielded video cable with ferrite cores Also a DSOXGPIB GPIB module may be ordered and installed separately 4 TRIG OUT Tri
94. X for the first and last points The bottom region is indicated by y values of MIN for the first and last points The top region must be the lowest numbered region in the file The bottom region must be the highest numbered region in the file Region number 1 is the top mask region The vertices in Region 1 describe points along a line that line is the bottom edge of the top portion of the mask Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Mask Testing 15 Similarly the vertices in Region 2 describe the line that forms the top of the bottom part of the mask The vertices in a mask file are normalized There are four parameters that define how values are normalized X1 AX Y1 Y2 These four parameters are defined in the Oscilloscope Setup portion of the mask file The Y values normally voltage are normalized in the file using the following equation Yhorm Y Y1 AY where AY Y2 Y1 To convert the normalized Y values in the mask file to voltage Y Ynorm AYY where AY Y2 Y1 The X values normally time are normalized in the file using the following equation Xnorm X X1 AX To convert the normalized X values to time X Xnorm AX X1 Oscilloscope The keywords setup and end_setup appearing alone on a line define the Setup Information beginning and end of the oscilloscope setup region of the mask file The oscilloscope setup information contains remote programming langu
95. X Series oscilloscope Power cord country of origin determines specific type Oscilloscope probes Two probes for 2 channel models Four probes for 4 channel models Documentation CD ROM 22 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Getting Started 1 N2862B probes Qty 2 or 4 Documentation CD Digital Probe Kit MSO models only Power cord Based on country of origin N6459 60001 Digital Probe Kit contains N6459 61601 8 channel cable qyt 1 01650 82103 2 inch probe ground leads qyt 3 5090 4832 Grabber qty 10 US t Digital probe replacement parts are listed in the Digital Channels chapter See Also Accessories Available on page 282 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 23 1 Getting Started Install the Optional LAN VGA or GPIB Module If you need to install a DSOXLAN LAN VGA module or a DSOXGPIB GPIB module perform this installation before you power on the oscilloscope 1 If you need to remove a module before installing a different module pinch the module s spring tabs and gently remove the module rom the slot 2 To install a module slide the module into the slot on the back until it is fully seated The module s spring tabs will latch into the slot keepi a i LANIVGA N Module zil m Device Host TRIG OUT EXT Tha IN ee R te Module Slot GPIB M
96. able modulation for all waveform generator function types except pulse DC and noise Press the Type softkey and turn the Entry knob to select the modulation type Amplitude Modulation AM the amplitude of the original carrier signal is modified according to the amplitude of the modulating signal See To set up Amplitude Modulation AM on page 217 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Waveform Generator 17 Frequency Modulation FM the frequency of the original carrier signal is modified according to the amplitude of the modulating signal See To set up Frequency Modulation FM on page 218 Frequency Shift Keying Modulation FSK the output frequency shifts between the original carrier frequency and a hop frequency at the specified FSK rate The FSK rate specifies a digital square wave modulating signal See To set up Frequency Shift Keying Modulation FSK on page 219 To set up Amplitude Modulation AM In the Waveform Generator Modulation Menu under Wave Gen gt Settings gt Modulation 1 Press the Type softkey and turn the Entry knob to select Amplitude Mod ulation AM 2 Press the Waveform softkey and turn the Entry knob to select the shape of the modulating signal Sine Square Ramp Sine Card inal Exponential Rise Exponential Fall When the Ramp shape is selected a Symmetry softkey appears so that you can specify the amount of time per cycle that the
97. age commands that the oscilloscope executes when the mask file is loaded Any legal remote programming command can be entered in this section The mask scaling controls how the normalized vectors are interpreted This in turn controls how the mask is drawn on the display The remote programming commands that control mask scaling are Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 203 15 Mask Testing MTES MTES MTES MTES MTES SCAI SCAI SCAI SCAI SCAI Bet Ete Building a Mask File 204 BIND 0 X1 400 000E 06 XDEL 800 000E 06 Y 1 359 000E 03 Y2 4 2 35900E 00 The following mask uses all eight mask regions The most difficult part of creating a mask file is normalizing the X and Y values from the time and voltage values This example shows an easy way to convert voltage and time to normalized X and Y values in the mask file The following mask file produced the mask shown above BW Limit MASK FILE 548XX All Regions Region Number 1 Number of vertices 4 12 50 10 00 10 00 12 50 MAX 1 750 1 750 MAX Region Number 2 Number of vertices 5 75 09 KEYSIGHT TECHNOLOGIES Acquisition Channels Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Mask Testing 15 10 00 1 000 12 50 0 500 15 00 0 500 15 00 1 500 12 50 1 500 Region Number 3 Number of vertices 6 05 00 1 000 0
98. age 303 LIN triggering can trigger on the rising edge at the Sync Break exit of the LIN single wire bus signal that marks the beginning of the message frame the Frame ID or the Frame ID and Data A LIN signal message frame is shown below Sync Sync _ Identifier Data Checksum Break Field Break Fields Field 4 Sync Break Exit Press Trigger 2 Inthe Trigger Menu press the Trigger softkey then turn the Entry knob to select the serial slot Serial 1 on which the CAN signal is being decoded Trigger Menu Trigger Trigger 5 LIN ID amp Data 3 Press the Trigger softkey then turn the Entry knob to select the trigger condition Sync Sync Break The oscilloscope triggers on the rising edge at the Sync Break exit of the LIN single wire bus signal that marks the beginning the message frame ID Frame ID The oscilloscope triggers when a frame with an ID equal to the selected value is detected Use the Entry knob to select the value for the Frame ID Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 305 23 CAN LIN Triggering and Serial Decode ID amp Data Frame ID and Data The oscilloscope triggers when a frame with an ID and data equal to the selected values is detected When triggering on a frame ID and data To select the frame ID value press the Frame ID softkey and use the Entry knob Note that you can enter a don t care value for the frame ID and trigger on data v
99. ailable for interleaved standards When a specific field is selected the oscilloscope triggers on the rising edge of the first serration pulse in the vertical sync interval in the specified field 1 or 2 134 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Triggers 10 1 Press the Trigger key 2 Inthe Trigger Menu press the Trigger softkey then turn the Entry knob to select Video 3 Press the Settings softkey then press the Standard softkey to select the appropriate TV standard 4 Press the Mode softkey and select Field1 or Field2 200 05 Vid Field1 KEYSIGHT TECHNO IES Acquisition Mode Field Holdoff Field1 O Oflds Figure 17 Triggering on Field 1 To trigger on all fields of the video signal To quickly and easily view transitions between fields or to find the amplitude differences between the fields use the All Fields trigger mode 1 Press the Trigger key 2 Inthe Trigger Menu press the Trigger softkey then turn the Entry knob to select Video 3 Press the Settings softkey then press the Standard softkey to select the appropriate TV standard 4 Press the Mode softkey and select All Fields Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 135 10 Triggers 200 08 o Vid All Fld KEYSIGHT TECHNOLOGIES Acquisition Channels Field Holdoff All Fields O Oflds Figure 18 Triggering on All Fields To trigger on odd or even fields To check the envelope of
100. al frames are not counted Counters The FRAMES counter gives the total number of completed remote data overload and active error frames The OVLD counter gives the total number of completed overload frames and heir percentage of the total number of frames The ERR counter gives the total number of completed active error frames and heir percentage of the total number of frames The UTIL bus load indicator measures the percentage of time the bus is active The calculation is done on 330 ms periods approximately every 400 ms faa Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 301 23 CAN LIN Triggering and Serial Decode Example If a data frame contains an active error flag both the FRAMES counter and the ERR counter will be incremented If a data frame contains an error that is not an active error it is considered a partial frame and no counters are incremented Interpreting CAN Lister Data ID 0296A95D DLC Data Data 5 at 00 01 02 03 04 9639 KEYSIGHT TECHNOLOGIES O7F RMT O7F Data 22 Acquisition RMT Data RMT Data 42 9A AG 9E Channels 0296A95D RMT O0296A95D Lister Menu Data 00 02 04 06 08 Zoom to Selection Options w In addition to the standard Time column the CAN Lister contains these columns ID frame ID Type frame type RMT remote frame or Data DLC da
101. alues only To set up the number of data bytes and enter their values in hexadecimal or binary press the Bits softkey to open the LIN Bits Menu Data Hex OW 00 01 00 Nibble Set all Nibs 1 1 For details about using the LIN Bits Menu softkeys press and hold the softkey in question to display the built in help For LIN decode information see LIN Serial Decode on page 306 LIN Serial Decode To set up the oscilloscope to capture LIN signals see Setup for LIN Signals on page 303 For LIN triggering setup see LIN Triggering on page 305 To set up LIN serial decode 306 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide CAN LIN Triggering and Serial Decode 23 1 Press Serial to display the Serial Decode Menu Serial Decode Menu Signals Show Parity Lister tll w 2 Choose whether to include the parity bits in the identifier field a Ifyou want to mask the upper two parity bits ensure that the box under the Show Parity softkey is not selected b If you want to include the parity bits in the identifier field ensure that the box under the Show Parity softkey is selected 3 Ifthe decode line does not appear on the display press the Serial key to turn it on 4 Ifthe oscilloscope is stopped press the Run Stop key to acquire and decode data If the setup does not produce a stable trigger the LIN signal may be slow enough that the oscilloscope is AutoTriggering P
102. and 200 MHz bandwidth models 2 and 4 channel digital storage oscilloscope DSO models 2 8 channel and 4 8 channel mixed signal oscilloscope MSO models Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide An MSO lets you debug your mixed signal designs using analog signals and tightly correlated digital signals simultaneously The 8 digital channels have a 1 GSa s sample rate with a 50 MHz toggle rate 8 5 inch WVGA display Interleaved 2 GSa s or non interleaved 1 GSa s sample rate 100 Kpts per channel MegaZoom IV acquisition memory for the fastest waveform update rates uncompromised Upgradeable to 1 Mpts per channel All knobs are pushable for making quick selections Trigger types edge pulse width pattern and video Serial decode trigger options for CAN LIN C SPI and UART RS232 There is a Lister for displaying serial decode packets Digital channels and serial decode cannot be on at the same time The Serial key takes precedence over the Digital key Serial triggers can be used when digital channels are on ath waveforms add subtract multiply and FFT Reference waveforms 2 for comparing with other channel or math waveforms any built in measurements Built in license enabled waveform generator with sine Square ramp pulse DC noise USB ports make printing saving and sharing data easy Optional LAN VGA module for connecting to a network and displaying the screen on a different m
103. and select a value In the decode display the chosen value will be displayed in light blue However if a parity error occurs the data will be displayed in red 5 Ifthe decode line does not appear on the display press the Serial key to turn it on 6 If the oscilloscope is stopped press the Run Stop key to acquire and decode data Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 333 25 UART RS232 Triggering and Serial Decode If the setup does not produce a stable trigger the UART RS232 signals may be slow enough that the oscilloscope is AutoTriggering Press the Mode Coupling key then press the Mode softkey to set the trigger mode from Auto to Normal You can use the horizontal Zoom window for easier navigation of the acquired data See Also Interpreting UART RS232 Decode on page 334 UART RS232 Totalizer on page 335 Interpreting UART RS232 Lister Data on page 336 Searching for UART RS232 Data in the Lister on page 336 Interpreting UART RS232 Decode Channels Serial Decode Menu AX F jd o Mode Lister UART AS232 all gt Angled waveforms show an active bus inside a packet frame Mid level blue lines show an idle bus When using 5 8 bit formats the decoded data is displayed in white in binary hex or ASCII When using the 9 bit format all data words are displayed in green including the Sth bit The 9th bit is displayed on the left 334 Keysight InfiniiVision 2000 X S
104. ant to test Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 85 6 Digital Channels 6 For high speed signals connect a ground lead to the probe lead connect a grabber to the ground lead and attach the grabber to ground in the device under test Ground Grabber 7 Repeat these steps until you have connected all points of interest Signals Ground 86 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Digital Channels 6 Acquiring waveforms using the digital channels When you press Run Stop or Single to run the oscilloscope the oscilloscope examines the input voltage at each input probe When the trigger conditions are met the oscilloscope triggers and displays the acquisition For digital channels each time the oscilloscope takes a sample it compares the input voltage to the logic threshold If the voltage is above the threshold the oscilloscope stores a 1 in sample memory otherwise it stores a 0 To display digital channels using AutoScale When signals are connected to the digital channels be sure to connect the ground leads AutoScale quickly configures and displays the digital channels To configure the instrument quickly press the AutoScale key 100 08 Auto 2 08V KEYSIGHT TECHNOLOGIES Channels et h Undo Fast Debug Channels Acq Mode Autoscale All Normal Figure8 Example AutoScale of digital channels MSO models only Any digital chann
105. appears in the Serial Decode Menu 1 Press Label to turn on labels 2 Press Serial 3 Press the Mode softkey then select CAN trigger type 4 Press the Signals softkey to open the CAN Signals Menu KEYSIGHT TECHNOLOGIES 295 23 CAN LIN Triggering and Serial Decode 296 Threshold Sample Point Signal 1 00V 75 0 Diff L H Press Source then select the channel for the CAN signal The label for the CAN source channel is automatically set Press the Threshold softkey then turn the Entry knob to select the CAN signal threshold voltage level The threshold voltage level is used in decoding and it will become the trigger level when the trigger type is set to the selected serial decode slot Press the Baud softkey then turn the Entry knob to select the baud rate that matches match your CAN bus signal The CAN baud rate can be set to predefined baud rates from 10 kb s up to 5 Mb s or a user defined baud rate from 10 0 kb s to 4 Mb s in increments of 100 b s Fractional user defined baud rates between 4 Mb s and 5 Mb s are not allowed The default baud rate is 125 kb s If none of the pre defined selections match your CAN bus signal select User Defined then press the User Baud softkey and turn the Entry knob to enter the baud rate Press the Sample Point softkey then turn the Entry knob to select the point between phase segments 1 and 2 where the state of the bus is measured This controls the point within
106. backward stop or play forward in time You can press the or keys multiple times to speed up the playback There are three speed levels Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 53 2 54 Horizontal Controls To navigate search events When acquisitions are stopped you can use the navigation controls to go to found search events set using the Search key and menu see Searching for Events on page 52 1 Press Navigate 2 Inthe Navigate Menu press Navigate then select Search 3 Press the OIC back and forward keys to go to the previous or next search event When searching Serial decode You can press the stop key to set or clear a mark The Auto zoom softkey specifies whether the waveform display is automatically zoomed to fit the marked row as you navigate Pressing the Scroll Lister softkey lets you use the Entry knob to scroll through data rows in the Lister display To navigate segments When the segmented memory acquisition is enabled and acquisitions are stopped you can use the navigation controls to play through the acquired segments 1 Press Navigate 2 Inthe Navigate Menu press Navigate then select Segments 3 Press Play Mode then select Manual to play through segments manually In the Manual play mode Press the IS back and forward keys to go to the previous or next segment Press the Id softkey to go to the first segment Press the Pl so
107. bit Triggers only when the 9th alert bit is O The specified dat excludes the 9th alert bit Rx X Data For use when the device under test da a byte applies to the least significant 8 bi a US ta words are 9 bits in length including the alert bit the 9th bit Triggers on a data byte that you specify regardless of the value of the 9th alert bit The specified data byte applies to the least significant 8 bits excludes the 9th alert bit Similar choices are available for Tx Rx or Tx Parity Error Triggers on a parity error based on the parity you have set in the Bus Configuration Menu lf you choose a trigger condition that includes Data in its description for example Rx Data then press the Data is softkey and choose an equality qualifier You can choose equal to not equal to less than or greater than a specific data value Use the Data softkey to choose the data value for your trigger comparison This works in conjunction with the Data is softkey Optional The Burst softkey lets you trigger on the Nth frame 1 4096 after an idle time you select All trigger conditions must be met for the trigger to occur lf Burst is selected an idle time 1 us to 10 s can be specified so that the oscilloscope will look for a trigger condition only after the idle time has past Press the Idle softkey and rotate the Entry knob to set an idle time If the setup doe
108. ccurately represent frequency components near DC FFT Aliasing When using FFTs it is important to be aware of frequency aliasing This requires that the operator have some knowledge as to what the frequency domain should contain and also consider the sampling rate frequency span and oscilloscope vertical bandwidth when making FFT measurements The FFT resolution the quotient of the sampling rate and the number of FFT points is displayed directly above the softkeys when the FFT Menu is displayed Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 4 76 Math Waveforms Nyquist Frequency and Aliasing in the Frequency Domain The Nyquist frequency is the highest frequency that any real time digitizing oscilloscope can acquire without aliasing This frequency is half of the sample rate Frequencies above the Nyquist frequency will be under sampled which causes aliasing The Nyquist frequency is also called the folding frequency because aliased frequency components fold back from that frequency when viewing the frequency domain Aliasing happens when there are frequency components in the signal higher than half the sample rate Because the FFT spectrum is limited by this frequency any higher components are displayed at a lower aliased frequency The following figure illustrates aliasing This is the spectrum of a 990 Hz square wave which has many harmonics The sample rate is set to 100 kSa s and the oscilloscop
109. ced and the Auto indicator is displayed Edge Trigger The Edge trigger type identifies a trigger by looking for a specified edge slope and voltage level on a waveform You can define the trigger source and slope in this menu The trigger type source and level if applicable are displayed in the upper right corner of the display 1 On the front panel in the Trigger section press the Trigger key 2 In the Trigger Menu press the Trigger softkey and use the Entry knob to select Edge 3 Select the trigger source Analog channel 1 to the number of channels Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 121 10 Triggers 122 Digital channel on mixed signal oscilloscopes DO to the number of digital channels minus one External triggers on the rear panel EXT TRIG IN signal Line triggers at the 50 level of the rising or falling edge of the AC power source signal WaveGen triggers at the 50 level of the rising edge of the waveform generator output signal Not available when the DC or Noise waveforms are selected You can choose a channel that is turned off not displayed as the source for the edge trigger The selected trigger source is indicated in the upper right corner of the display next to the slope symbol 1 through 4 analog channels DO through Dn digital channels E External trigger input L Line trigger W Waveform generator Press the Slope soft
110. cilloscope and obtain a stable display 2 To find the glitch press the Acquire key then press the Acq Mode softkey until Peak Detect is selected 3 Press the Display key then press the Persistence infinite persistence softkey Infinite persistence updates the display with new acquisitions but does not erase previous acquisitions New sample points are shown at normal intensity while previous acquisitions are displayed at reduced intensity Waveform persistence is not kept beyond the display area boundary Press the Clear Display softkey to erase previously acquired points The display will accumulate points until o Persistence is turned off 4 Characterize the glitch with Zoom mode a Press the zoom key or press the Horiz key and then the Zoom softkey b To obtain a better resolution of the glitch expand the time base Use the horizontal position knob 4 to pan through the waveform to set the expanded portion of the normal window around the glitch Averaging Acquisition Mode The Averaging mode lets you average multiple acquisitions together to reduce noise and increase vertical resolution at all time div settings Averaging requires a stable trigger The number of averages can be set from 2 to 65536 in power of 2 increments A higher number of averages reduces noise more and increases vertical resolution Avgs Bits of resolution 2 8 4 9 16 10 64 11 2 256 12 158 Keysight I
111. click on a softkey Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 265 21 Web Interface i VNC Agilent MSOX2024A InfiniiVision US50210029 Remote Front Panel Main Menu _ z gt Function Keys Hint appears lt when you roll over with mouse Softkeys left click to select right click for Quick Help Scrollingand When using a monitor resolution of 800 x 600 or less on the remote computer you Monitor need to scroll to access the full remote front panel To display the remote front Resolution panel without scroll bars use a monitor resolution greater than 800 x 600 on your computer s display Browser Based Remote Front Panel To operate the oscilloscope using the web interface s Browser Based Remote Front Panel 1 Access the oscilloscope s web interface see Accessing the Web Interface on page 262 2 When the oscilloscope s web interface is displayed select Browser Web Control then select Browser Based Remote Front Panel After a few seconds the Remote Front Panel appears 3 Click keys or knobs that you would normally press on the oscilloscope s front panel Buttons have been added for turning knobs 266 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Web Interface 21 Ms0 x MA MSO X 2024A Fun Control YE Agilent Technologies InfiniiVision MSO X 2024A noe 0 L J Single Remote Programming via the Web Interface To send r
112. cope to capture 12C signals see Setup for I2C Signals on page 311 For 12C triggering setup see I2C Triggering on page 312 To set up 12C serial decode 1 Press Serial to display the Serial Decode Menu Serial Decode Menu Mode Signals Addr Size PC 7 Bit 2 Choose 7 bit or 8 bit address size Use 8 bit address size to include the R W bit as part of the address value or choose 7 bit address size to exclude the R W bit from the address value 3 Ifthe decode line does not appear on the display press the Serial key to turn it on 4 Ifthe oscilloscope is stopped press the Run Stop key to acquire and decode data If the setup does not produce a stable trigger the I2C signals may be slow enough that the oscilloscope is AutoTriggering Press the Mode Coupling key then press the Mode softkey to set the trigger mode from Auto to Normal You can use the horizontal Zoom window for easier navigation of the acquired data Interpreting I2C Decode on page 317 Interpreting 12C Lister Data on page 318 Searching for I2C Data in the Lister on page 318 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide I2C SPI Triggering and Serial Decode 24 Interpreting 12C Decode 200 08 20 1 40V KEYSIGHT TECHNOLOGIES Channels Signals Addr Size Lister 7 Bit gt Angled waveforms show an active bus inside a packet frame Mid level blue lines show an idle bus In the decoded hexadecimal data
113. copes User s Guide 299 20 Utility Settings 2 Re On ame and address of owner odel number Serial number Description of service required or failure indication move accessories from the oscilloscope y return accessories to Keysight Technologies if they are associated with the failure symptoms 3 Pa ckage the oscilloscope You can use the original shipping container or provide your own materials sufficient to protect the instrument during shipping 4 Se al the shipping container securely and mark it FRAGILE Configuring the Quick Action Key 256 The Quick Action key lets you perform common repetitive actions by pressing a single key To co nfigure the Quick Action key 1 Press Utility gt Quick Action gt Action then select the action that should be performed Off disables the Quick Action key Quick Measure All displays a popup containing a snapshot of all the single waveform measurements The Source softkey lets you select the waveform source which also becomes the source selection in the Measurement Menu See Chapter 14 Measurements starting on page 175 Quick Print prints the current screen image Press Settings to set up the printing options See Chapter 19 Print Screens starting on page 235 Quick Save saves the current image waveform data or setup Press Settings to set up the save options See Chapter 18 Save Recall Setups Scr
114. ctions Note that the curved arrow symbol a above the entry knob illuminates whenever the entry knob can be used to select a value Also note that when the Entry knob a symbol appears on a softkey you can use the Entry knob to select values Often rotating the Entry knob is enough to make a selection Sometimes you can push the Entry knob to enable or disable a selection Pushing the Entry knob also makes popup menus disappear Tools keys Trigger controls The Tools keys consist of Utility key Press this key to access the Utility Menu which lets you configure the oscilloscope s 1 0 settings use the file explorer set preferences access the service menu and choose other options See Chapter 20 Utility Settings starting on page 241 Quick Action key Press this key to perform the selected quick action measure all snapshot print save recall freeze display and more See Configuring the Quick Action Key on page 256 Analyze key Press this key to access analysis features like mask testing see Chapter 15 Mask Testing starting on page 195 trigger level setting measurement threshold setting or Video trigger automatic set up and display Wave Gen key Press this key to access waveform generator functions See Chapter 17 Waveform Generator starting on page 211 These controls determine how the oscilloscope triggers to capture data See Chapter 10
115. cts analog channel waveforms only not math waveforms referencewaveforms digital waveforms etc KEYSIGHT TECHNOLOGIES 107 8 Display Settings 2 14V KEYSIGHT TECHNO Acquisition Channels 10 0 1 nu Trigger Source Edge 2 Figure 13 Amplitude Modulation Shown at 100 Intensity Channels 10 0 1 10 0 1 Trigger gt Source Edge 2 Figure 14 Amplitude Modulation Shown at 40 Intensity 108 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Display Settings 8 To set or clear persistence With persistence the oscilloscope updates the display with new acquisitions but does not immediately erase the results of previous acquisitions All previous acquisitions are displayed with reduced intensity New acquisitions are shown in their normal color with normal intensity Waveform persistence is kept only for the current display area you cannot pan and zoom the persistence display To use persistence 1 Press the Display key 2 Press Persistence then turn the Entry knob to select between Off turns off persistence When persistence is off you can press the Capture Waveforms softkey to perform a single shot infinite persistence A single acquisition s data is displayed with reduced intensity and it remains on the display until you clear persistence or clear the display oo Persistence infinite presistence Results of previous acquisitions are never erased Use infinite p
116. d SYNC will appear in red If the header exceeds the length specified in the standard THM will appear red Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide CAN LIN Triggering and Serial Decode 23 If the total frame count exceeds the length specified in the standard TFM will appear red LIN 1 3 only For LIN 1 3 a wakeup signal is indicated by WAKE in blue If the wakeup signal is not followed by a valid wakeup delimiter a wakeup error is detected and displayed as WUP in red Interpreting LIN Lister Data 30 572 370 487 Stop 1 11 a Checksum Errors KEYSIGHT 13 31ms 4D 53 4F EE a TECHNOLOGIES 2 759ms 00 F Acquistion 7 798ms 27 AA 90 AO A3 24 18 35ms AQ A er 0 0 39 46ms 13 55 48 DO 51 12 50 02ms D4 53 B a Channels 60 57ms 71 13ms 89 2A 24 E8 28 89 Data 00 80 Lister Menu Display Zoom to S LIN Selection In addition to the standard Time column the LIN Lister contains these columns ID frame ID Data LIN 1 3 only data bytes Checksum LIN 1 3 only Data and Checksum LIN 2 0 only Errors highlighted in red Aliased data is highlighted in pink When this happens decrease the horizontal time div setting and run again Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 309 23 CAN LIN Triggering and Serial Decode 310 Searching for LIN Data in the Lister The oscilloscope s search capability lets you search f
117. decode line indicate that there is data that is not being displayed Scroll or expand the horizontal scale to view the information 300 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide CAN LIN Triggering and Serial Decode 23 Aliased bus values undersampled or indeterminate are drawn in pink Unknown bus values undefined or error conditions are drawn in red with a label Flagged error frames are drawn in red with an ERR label CAN Totalizer The CAN totalizer provides a direct measure of bus quality and efficiency The CAN totalizer measures total CAN frames flagged error frames overload frames and bus utilization FRAMES 1350658396 OVLD 268440068 19 9 6 UTIL 24 1 Signals Mode CAN The totalizer is always running counting frames and calculating percentages and is displayed whenever CAN decode is displayed The totalizer counts even when the oscilloscope is stopped not acquiring data Pressing the Run Stop key does not affect the totalizer When an overflow condition occurs the counter displays OVERFLOW The counters can be reset to zero by pressing the Reset CAN Counters softkey Types of Frames Active error frames are CAN frames in which a CAN node recognizes an error condition during a data or remote frame and issues an active error flag A partial frame occurs when the oscilloscope detects any error condition during a frame that is not followed by an active error flag Parti
118. display See To choose expand about center or ground on page 247 To adjust the vertical position 1 Turn the small vertical position knob to move the channel s waveform up or down on the display The voltage value momentarily displayed in the upper right portion of the display represents the voltage difference between the vertical center of the display and the ground level icon It also represents the voltage at the vertical center of the display if vertical expansion is set to expand about ground see To choose expand about center or ground on page 247 To specify channel coupling Coupling changes the channel s input coupling to either AC alternating current or DC direct current TIP If the channel is DC coupled you can quickly measure the DC component of the signal by simply noting its distance from the ground symbol If the channel is AC coupled the DC component of the signal is removed allowing you to use greater sensitivity to display the AC component of the signal Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 59 3 Vertical Controls 1 Press the desired channel key 2 Inthe Channel Menu press the Coupling softkey to select the input channel coupling DC DC coupling is useful for viewing waveforms as low as 0 Hz that do not have large DC offsets AC AC coupling is useful for viewing waveforms with large DC offsets AC coupling places a 10 Hz high pass filter in s
119. e Instrument Utilities on page 272 Binary Data bin Format 284 The binary data format stores waveform data in binary format and provides data headers that describe that data Because the data is in binary format the size of the file is approximately 5 times smaller than the ASCII XY format Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Reference 22 If more than one source is on all displayed sources will be saved except math functions When using segmented memory each segment is treated as a separate waveform All segments for a channel are saved then all segments of the next higher numbered channel are saved This continues until all displayed channels are saved When the oscilloscope is in the Peak Detect acquisition mode the minimum and maximum value waveform data points are saved to the file in separate waveform buffers The minimum value data points are saved first then the maximum value data points are saved BIN data using When saving all segments each segment has its own waveform header see segmented Binary Header Format on page 286 an In BIN file format data are presented as follows Channel 1 data all segments Channel 2 data all segments Channel 3 data all segments Channel 4 data all segments Digital channel data all segments Math waveform data all segments When not saving all segments the number of waveforms is equivalent to the number of active c
120. e SGM Segmented Memory Order DSOX2SGM Lets you capture infrequent or burst signals with great resolution by eliminating the capture of your signal s inactivity WAVEGEN Waveform Generator Order DSOX2WAVEGEN Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 283 22 Reference Other Options Available Table 10 Calibration Option Option Order A6J ANSI Z540 Compliant Calibration Upgrading to an MSO A license can be installed to activate the digital channels of an oscilloscope that was not originally ordered as a mixed signal oscilloscope MSO A mixed signal oscilloscope has analog channels plus 8 time correlated digital timing channels For information about upgrading your oscilloscope through licensing contact your local Keysight Technologies representative or see www keysight com find 2000X Series Software and Firmware Updates From time to time Keysight Technologies releases software and firmware updates for its products To search for firmware updates for your oscilloscope direct your web browser to www keysight com find 2000X Series sw To view the currently installed software and firmware press Help gt About Oscilloscope Once you have downloaded a firmware update file you can place it on a USB storage device and load the file using File Explorer see File Explorer on page 245 or you can use the Instrument Utilities page of the oscilloscope s web interface se
121. e t SOF edge After setting up the oscilloscope to capture a CAN signal 1 Press Trigger 2 Inthe Trigger Menu press the Trigger softkey then turn the Entry knob to select the serial slot Serial 1 on which the CAN signal is being decoded Trigger Menu Trigger Trigger S CAN All Errors 3 Press the Trigger softkey then turn the Entry knob to select the trigger condition SOF Start of Frame The oscilloscope triggers at the start of a frame Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 297 23 CAN LIN Triggering and Serial Decode Remote Frame ID RTR The oscilloscope triggers on remote frames with the specified ID Press the Bits softkey to select the ID Data Frame ID RTR The oscilloscope will trigger on data frames matching the specified ID Press the Bits softkey to select the ID Remote or Data Frame ID The oscilloscope will trigger on remote or data frames matching the specified ID Press the Bits softkey to select the ID Data Frame ID and Data The oscilloscope will trigger on data frames matching the specified ID and data Press the Bits softkey to select the ID and set up the number of data bytes and values Error Frame The oscilloscope will trigger on CAN active error frames All Errors The oscilloscope will trigger when any form error or active error is encountered Acknowledge Error The oscilloscope will trigger when the acknowledge bit is
122. e 233 18 Save Recall Setups Screens Data 234 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens To print the oscilloscope s display 235 To set up network printer connections 236 To specify the print options 238 To specify the palette option 238 You can print the complete display including the status line and softkeys to a USB printer or a network printer when the DSOXLAN LAN VGA module is installed The Print Configuration Menu is displayed when you press the Print key The print option softkeys and the Press to Print softkey are ghosted not available until a printer is connected To print the oscilloscope s display 1 Connect a printer You can Connect a USB printer to either the USB port on the front panel or the rectangular USB host port on the rear panel For the most up to date listing of printers that are compatible with the InfiniiVision oscilloscopes please visit www keysight com find InfiniiVision printers Set up a network printer connection See To set up network printer connections on page 236 2 Press the Print key on the front panel 3 In the Print Configuration Menu press the Print to softkey then turn the Entry knob to select the desired printer KEYSIGHT TECHNOLOGIES 235 19 Print Screens 4 Press the Options softkey to select the print options O la Print Confi
123. e Save Recall Menu there are also options for restoring the complete factory settings see Recalling Default Setups on page 232 or performing a secure erase see Performing a Secure Erase on page 233 Use Auto Scale Use Auto Scale to automatically configure the oscilloscope to best display the input signals 1 Press Auto Scale You should see a waveform on the oscilloscope s display similar to this 200 08 1 34V EYSIGH TECHNOLOGIES Acquisition Channels Menu Undo Fast Debug Channels Acq Mode Autoscale All Normal Autose 2 If you want to return to the oscilloscope settings that existed before press Undo AutoScale 3 If you want to enable fast debug autoscaling change the channels autoscaled or preserve the acquisition mode during autoscale press Fast Debug Channels or Acq Mode These are the same softkeys that appear in the AutoScale Preferences Menu See To set AutoScale preferences on page 249 28 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide How AutoScale Works Compensate Getting Started 1 f you see the waveform but the square wave is not shaped correctly as shown above perform the procedure Compensate Passive Probes on page 29 f you do not see the waveform make sure the probe is connected securely to the front panel channel input BNC and to the left side Demo 2 Probe Comp terminal Auto Scale analyzes any waveforms present at each channel and at t
124. e calibrations for probes that can be calibrated Note that passive probes do not need to be calibrated Results User Cal date Change in temperature since last User Cal Failure Comments Probe Cal Status To clean the oscilloscope 1 Remove power from the instrument 2 Clean the external surfaces of the oscilloscope with a soft cloth dampened with a mixture of mild detergent and water 3 Make sure that the instrument is completely dry before reconnecting it to a power source To check warranty and extended services status To learn the warranty status of your oscilloscope 1 Point your web browser to www keysight com find warrantystatus 2 Enter your product s model number and serial number The system will search for the warranty status of your product and display the results If the system cannot find your product s warranty status select Contact Us and speak with a Keysight Technologies representative To contact Keysight Information on contacting Keysight Technologies can be found at www keysight com find contactus To return the instrument Before shipping the oscilloscope to Keysight Technologies contact your nearest Keysight Technologies sales or service office for additional details Information on contacting Keysight Technologies can be found at www keysight com find contactus 1 Write the following information on a tag and attach it to the oscilloscope Keysight InfiniiVision 2000 X Series Oscillos
125. e digital channels cable on an MSO and allow the oscilloscope to warm up before performing this procedure 2 Press the rear panel CAL button to disable calibration protection 3 Connect short 12 inch maximum equal length cables to each analog channel s BNC connector on the front of the oscilloscope You will need two equal length cables for a 2 channel oscilloscope or four equal length cables for a 4 channel oscilloscope Use 50W RG58AU or equivalent BNC cables when performing User Cal For a 2 channel oscilloscope connect a BNC tee to the equal length cables Then connect a BNC f to BNC f also called a barrel connector to the tee as shown below Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Utility Settings 20 Long cable to TRIG OUT To Channel 1 AF To Channel 2 Figure 36 User Calibration cable for 2 channel oscilloscope For a 4 channel oscilloscope connect BNC tees to the equal length cables as shown below Then connect a BNC f to BNC f barrel connector to the tee as shown below To Channel 1 Ba Figs Maes Ny To Channel 4 Longer cable to TRIG OUT Figure 37 User Calibration cable for 4 channel oscilloscope Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 253 20 Utility Settings 4 Connect a BNC cable 40 inches maximum from the TRIG OUT connector on the rear panel to the BNC barrel connector 5 Press the Utility key then press the Service softkey
126. e displayed in the easurements information area on the right hand side of the screen Cursors are turned on to show the portion of the waveform being measured for the ost recently selected measurement bottom most on the right side measurement are 3 Post Acquisition Processing In addition to changing display parameters after the acquisition you can perform all of the measurements and math functions after the acquisition Measurements and math functions will be recalculated as you pan and zoom and turn channels on and off As you zoom in and out on a signal using the horizontal scale knob and vertical volts division knob you affect the resolution of the display Because measurements and math functions are performed on displayed data you affect the resolution of functions and measurements KEYSIGHT TECHNOLOGIES 175 14 Measurements To make automatic measurements 176 1 Press the Meas key to display the Measurement Menu Source Add Settings Clear Meas Measurement oe Press the Source softkey to select the channel running math function or reference waveform to be measured Only channels math functions or reference waveforms that are displayed are available for measurements If a portion of the waveform required for a measurement is not displayed or does not display enough resolution to make the measurement the result will display No Edges Clipped Low Signal lt value or gt value or a sim
127. e displays the spectrum The displayed waveform shows the components of the input signal above the Nyquist frequency to be mirrored aliased on the display and reflected off the right edge 50 002 O 0V KEYSIGHT TECHNOLOGIES Acquisition Channels Cursors 120 500dB tit FFT Ch3 Scale FFT Resolution 1Hz Function Operator Source 1 Center More FFT tit FFT 25 0kHz d Figure 7 Aliasing Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Math Waveforms 4 Because the frequency span goes from 0 to the Nyquist frequency the best way to prevent aliasing is to make sure that the frequency span is greater than the frequencies of significant energy present in the input signal FFT Spectral Leakage The FFT operation assumes that the time record repeats Unless there is an integral number of cycles of the sampled waveform in the record a discontinuity is created at the end of the record This is referred to as leakage In order to minimize spectral leakage windows that approach zero smoothly at the beginning and end of the signal are employed as filters to the FFT The FFT Menu provides four windows Hanning Flat Top Rectangular and Blackman Harris For more information on leakage see Keysight Application Note 243 The Fundamentals of Signal Analysis at http literature cdn keysight com litweb pdf 5952 8898E pdf Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 4 Math Waveforms
128. e information area To make cursor measurements 166 1 Connect a signal to the oscilloscope and obtain a stable display 2 Press the Cursors key The Cursors box in the right side information area appears indicating that cursors are on Press the Cursors key again when you want to turn cursors off 3 In the Cursors Menu press Mode then select the desired mode Manual AX 1 AX and AY values are displayed AX is the difference between the X1 and X2 cursors and AY is the difference between the Y1 and Y2 cursors Cursors Menu Mode Source Manual Track Waveform As you move a marker horizontally the vertical amplitude of the waveform is tracked and measured The time and voltage positions are shown for the markers The vertical Y and horizontal X differences between the markers are shown as AX and AY values Binary Logic levels of displayed waveforms at the current X1 and X2 cursor positions are displayed above the softkeys in binary The display is color coded to match the color of the related channel s waveform Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Cursors 13 Cursors Menu Mode Source Cursors Binary X1 Hex Logic levels of displayed waveforms at the current X1 and X2 cursor positions are displayed above the softkeys in hexadecimal Cursors Menu Mode Source Cursors Units Hex X1 a Manual and Track Waveform modes can be used on waveforms that are
129. e s search capability lets you search for and mark certain types of SPI data in the Lister You can use the Navigate key and controls to navigate through the marked rows 1 With SPI selected as the serial decode mode press Search 2 Inthe Search Menu press the Search softkey then turn the Entry knob to select the serial slot Serial 1 or Serial 2 on which the SPI signals are being decoded 3 Press Search then select from these options Master Out Slave In MOSI Data for searching MOSI data Master In Slave Out MISO Data for searching MISO data 4 Press the Bits softkey to open the SPI Bits Search Menu Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 327 24 12C SPI Triggering and Serial Decode 5 In the SPI Bits Search Menu use the Words softkey to specify the number of words in the data value then use the remaining softkeys to enter the hex digit values For more information on searching data see Searching Lister Data on page 104 For more information on using the Navigate key and controls see Navigating the Time Base on page 53 328 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 29 UART RS232 Triggering and Serial Decode Setup for UART RS232 Signals 329 UART RS232 Triggering 331 UART RS232 Serial Decode 333 UART RS232 triggering and serial decode requires Option COMP or the DSOX3COM
130. e the Operator Source 1 and Source 2 softkeys to set up an arithmetic operation 3 Press the Function softkey and select f t Displayed 4 Use the Operator softkey to select a transform function FFT Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Math Waveforms 4 5 Press the Source 1 softkey and select g t as the source Note that g t is only available when you select a transform function in the previous step To adjust the math waveform scale and offset 1 Make sure the multiplexed scale and position knobs to the right of the Math key are selected for the math waveform lf the arrow to the left of the Math key is not illuminated press the key 2 Use the multiplexed scale and position knobs just to the right of the Math key to re size and re position the math waveform Math Scale and Offset are Set Automatically Any time the currently displayed math function definition is changed the function is automatically scaled for optimum vertical scale and offset If you manually set scale and offset for a function select a new function then select the original function the original function will be automatically rescaled See Also Units for Math Waveforms on page 67 Units for Math Waveforms Units for each input channel can be set to Volts or Amps using the Units softkey in the channel s Probe Menu Units for math function waveforms are Math function Units add or subtract VorA
131. e used Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Utility Settings 20 File Explorer The File Explorer lets you navigate the oscilloscope s internal file system and the file systems of connected USB storage devices From the internal file system you can load oscilloscope setup files or mask files From a connected USB storage device you can load setup files mask files license files firmware update cab files label files etc Also you can delete files on a connected USB storage device The USB port on the front panel and the USB port on the rear panel labeled HOST are USB Series A receptacles These are the receptacles to which you can connect USB mass storage devices and printers The square receptacle on the rear panel labeled DEVICE is provided for controlling the oscilloscope over USB See the Programmer s Guide for more information The oscilloscope s internal file system under Keysight Flash consists of 10 locations for oscilloscope setup files and four locations for mask files To use the File Explorer 1 Press Utility gt File Explorer 2 Inthe File Explorer Menu press the softkey in the first position and use the Entry knob to navigate Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 245 20 Utility Settings 246 USB Storage Devices 500 05 TECHN Acquisition Channels SMS02000 The softkey in the first position can have these labels
132. easurements 176 Measurements Summary 177 Snapshot All 178 Voltage Measurements 179 Peak Peak 180 Maximum 180 Minimum 180 Amplitude 180 Top 180 Base 181 Overshoot 181 Preshoot 183 Average 183 DCRMS 184 AC RMS 184 Time Measurements 186 Period 186 Frequency 187 Width 188 Width 188 Duty Cycle 188 Rise Time 188 FallTime 188 Delay 189 Phase 190 Measurement Thresholds 191 Measurement Window with Zoom Display 193 15 Mask Testing To create a mask from a golden waveform Automask 195 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Mask Test Setup Options 197 Mask Statistics 200 To manually modify a mask file 201 Building a Mask File 204 How is mask testing done 206 16 Digital Voltmeter 17 Waveform Generator To select generated waveform types and settings 211 To output the waveform generator sync pulse 214 To specify the expected output load 214 To use waveform generator logic presets 215 To add noise to the waveform generator output 215 To add modulation to the waveform generator output 216 To set up Amplitude Modulation AM 217 To set up Frequency Modulation FM 218 To set up Frequency Shift Keying Modulation FSK 219 To restore waveform generator defaults 220 18 Save Recall Setups Screens Data Saving Setups Screen Images or Data 223 To save setup files 225 To save BMP or PNG i
133. ecode slot 7 Press the Baud Rate softkey to open the LIN Baud Rate Menu 8 Press the Baud softkey then turn the Entry knob to select the baud rate that 9 matches match your LIN bus signal The default baud rate is 19 2 kb s If none of the pre defined selections match your LIN bus signal select User Defined then press the User Baud softkey and turn the Entry knob to enter the baud rate You can set the LIN baud rate from 2 4 kb s to 625 kb s in increments of 100 b s Press the Back Up key to return to the LIN Signals Menu 10 Press the Sample Point softkey then turn the Entry knob to select the sample point at which the oscilloscope will sample the bit value 60 j 70 Sample Point 80 11 Press the Standard softkey then turn the Entry knob to select the LIN standard 304 you are measuring LIN 1 3 or LIN 2 0 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide CAN LIN Triggering and Serial Decode 23 For LIN 1 2 signals use the LIN 1 3 setting The LIN 1 3 setting assumes the signal follows the Table of Valid ID Values as shown in section A 2 of the LIN Specification dated December 12 2002 If your signal does not comply with the table use the LIN 2 0 setting 12 Press the Sync Break softkey and select the minimum number of clocks that define a sync break in your LIN signal LIN Triggering To set up the oscilloscope to capture a LIN signal see Setup for LIN Signals on p
134. ed instrument TECHNOLOGIES from Keysight Technologies MSO X 2024A Information about this Web Enabled Instrument Instrument MSO X 2024A Oscilloscope Serial Number US50210029 Description Agilent ee R DNS Hostname 141 121 237 192 NetBIOS Name a mx2024a 10029 Multicast DNS Hostname a mx2024a 10029 local IP Address 141 121 237 192 VISA TCP IP Connect String TCPIPO 141 121 237 192 INSTR id Advanced information Identification off on Use the navigation bar on the left to access your oscilloscope and related information Keysight Technologies Inc 2006 2014 Browser Web Control The web interface s Browser Web Control page gives you access to The Real Scope Remote Front Panel see Real Scope Remote Front Panel on page 264 The Simple Remote Front Panel see Simple Remote Front Panel on page 265 The Browser Based Remote Front Panel see Browser Based Remote Front Panel on page 266 The SCPI Command window applet for Remote Programming see Remote Programming via the Web Interface on page 267 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 263 21 264 Web Interface If Java is not installed on your PC you will be prompted to install the Sun Microsystems Java Plug in This plug in must be installed on the controlling PC for the web interface s Remote Front Panel or Remote Programming operations The SCPI Command window is useful for testing commands
135. ed outdoor environment Probes and Accessories This setion lists the probes and accessories that are compatible with the 2000 X Series oscilloscopes Passive Probes on page 280 Differential Probes on page 281 Current Probes on page 281 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 279 22 Reference Accessories Available on page 282 Because the 2000 X Series oscilloscopes do not have a ring around the BNC connector for identifying probes you must set the probe attenuation factor manually See To specify the probe attenuation on page 62 See Also For more information on probes and accessories see www keysight com for Probes and Accessories Selection Guide 5989 6162EN 5000 6000 and 7000 Series InfiniiVision Oscilloscope Probes and Accessories Data Sheet 5968 8153EN Passive Probes Passive probes are included with the 2000 X Series oscilloscopes for each analog channel The following passive probes can be used with the InfiniiVision 2000 X Series oscilloscopes Any combination of passive probes can be used Table 5 Passive Probes Model Description 1165A Passive probe 10 1 600 MHz 1 5 m 10070C D Passive probe 1 1 20 MHz 1 5 m 10073C Passive probe 10 1 500 MHz 1 5 m 10074C Passive probe 10 1 150 MHz 1 5 m 10076A B Passive probe 100 1 4 kV 250 MHz N2771A B Passive probe 1000 1 30 kV 50 MHz N2862
136. een completed The specified minimum number of tests may be exceeded If an error occurs the action specified using the On Error softkey will occur The actual number of tests completed is displayed above the softkeys Minimum Time Choose this option and then use the Test Time softkey to select how long the oscilloscope will run When the selected time has passed the oscilloscope will stop The specified time may be exceeded If an error occurs the action specified using the On Error softkey will occur The actual test time is displayed above the softkeys Minimum Sigma Choose this option and then use the Sigma softkey to select a minimum sigma The mask test runs until enough waveforms are tested to achieve a minimum test sigma If an error occurs the oscilloscope will perform the action specified by the On Error softkey Note that this is a test sigma the max achievable process sigma assuming no defects for a certain number of tested waveforms as opposed to a process sigma which is tied to the amount of failures per test The sigma value may exceed the selected value when a small sigma value is chosen The actual sigma is displayed Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Mask Testing 15 On Error The On Error setting specifies the action s to take when the input waveform does not conform to the mask This setting supersedes the Run Until setting Stop The oscilloscope will stop whe
137. eens Data starting on page 223 Quick Recall recalls a setup mask or reference waveform Press Settings to set up the recall options See Chapter 18 Save Recall Setups Screens Data starting on page 223 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Utility Settings 20 Quick Freeze Display freezes the display without stopping running acquisitions or un freezes the display if currently frozen For more information see To freeze the display on page 111 Quick Trigger Mode toggles the trigger mode between Auto and Normal see To select the Auto or Normal trigger mode on page 142 Quick Clear Display clears the display see To clear the display on page 110 Once the Quick Action key is configured you simply press it to perform the selected action Adding an Annotation You can add an annotation to the upper left corner of the oscilloscope s display The annotation is useful for documentation purposes to add notes before capturing screens To add an annotation 1 oF OO N On the oscilloscope s front panel press Utility In the Utility Menu press Annotation In the Annotation Menu press Annotation to enable the annotation Press Edit In the Edit Annotation Menu Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 257 20 Utility Settings 500 08 TECHN Acquisition with infrequent glitch Channels Edit Annotation Menu Spe
138. el with an active signal will be displayed Any digital channels without active signals will be turned off Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 87 6 Digital Channels To undo the effects of AutoScale press the Undo AutoScale softkey before pressing any other key This is useful if you have unintentionally pressed the AutoScale key or do not like the settings AutoScale has selected This will return the oscilloscope to its previous settings See also How AutoScale Works on page 29 To set the instrument to the factory default configuration press the Default Setup key Interpreting the digital waveform display The following figure shows a typical display with digital channels Delay Time Trigger Trigger time div mode or type and run status source Threshold level Channels J n Digital lt _ _ Activity channel indicators identifiers D 44 44220 Turn off Thresholds Bus D7 DO w Waveform Turn Turn Threshold size individual groups of menu key channels channels on off on off 88 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Digital Channels 6 Activity indicator When any digital channels are turned on an activity indicator is displayed in the status line at the bottom of the display A digital channel can be always high always low w or actively toggling logic states f Any channel that is turned off will be grayed out in the activ
139. els after pressing AutoScale Press the Acq Mode softkey and turn the Entry knob to select whether the acquisition mode should be preserved during autoscale Normal to make the oscilloscope switch to Normal acquisition mode whenever the AutoScale key is pressed This is the default mode Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 249 20 Utility Settings Preserve to make the oscilloscope remain in the acquisition mode you have chosen when the AutoScale key is pressed Setting the Oscilloscope s Clock The Clock Menu lets you set the current date and time of day 24 hour format This time date stamp will appear on hardcopy prints and directory information on the USB mass storage device To set the date and time or to view the current date and time 1 Press Utility gt Options gt Clock Clock Menu Year Hour Minute at i 2010 0 t3 52 2 Press the Year Month Day Hour or Minute softkey then rotate the Entry knob to set to the desired number The hours are shown in the 24 hour format So 1 00 PM is hour 13 The real time clock only allows selection of valid dates If a day is selected and the month or year is changed so the day is invalid the day is automatically adjusted Setting the Rear Panel TRIG OUT Source You can choose the source of the TRIG OUT connector on the rear panel of the oscilloscope 1 Press Utility gt Options gt Rear Panel 2 Inthe Rear Panel Menu
140. emote programming commands to the oscilloscope via the SCPI Commands applet window 1 Access the oscilloscope s web interface see Accessing the Web Interface on page 262 2 When the oscilloscope s web interface is displayed select Browser Web Control then select Remote Programming The SCPI Commands applet appears within the browser web page Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 267 21 268 Web Interface KEYSIGHT TECHNOLOGIES pegmatite te Remote Programming You can send remote programming commands directly to your MSO X 2024A oscilloscope using the tool below commands see the Programming Commands Quick Reference mi Browser Web Control Clear J Commands Options aaa IDN lf Successfully connected to Agilent MSOX2024A InfiniiVision US50210029 gt IDN lt AGILENT TECHNOLOGIES MSO X 2024A US50210029 02 38 2014102201 Remote Programming with Keysight IO Libraries While the SCPI Commands applet window lets you enter and remote programming commands remote programming for automated test and data acquisition is typically done using the Keysight IO Libraries which are separate from the instrument s web interface The Keysight IO Libraries let a controller PC communicate with Keysight InfiniiVision oscilloscopes via their USB LAN when the LAN VGA option module is installed or GPIB when the GPIB opt
141. ength is greater for a single acquisition than when the and Record Length oscilloscope is running or when the oscilloscope is stopped after running Single Single acquisitions always use the maximum memory available at least twice as much memory as acquisitions captured when running and the oscilloscope stores at least twice as many samples At slower time div settings because there is more memory available for a single acquisition the acquisition has a higher effective sample rate Running When running versus taking a single acquisition the memory is divided in half This lets the acquisition system acquire one record while processing the previous acquisition dramatically improving the number of waveforms per second processed by the oscilloscope When running a high waveform update rate provides the best representation of your input signal To acquire data with the longest possible record length press the Single key For more information on settings that affect record length see Length Control on page 227 Overview of Sampling To understand the oscilloscope s sampling and acquisition modes it is helpful to understand sampling theory aliasing oscilloscope bandwidth and sample rate oscilloscope rise time oscilloscope bandwidth required and how memory depth affects sample rate 150 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Acquisition Control 12 Sampling Theory The Nyqu
142. eries Oscilloscopes User s Guide UART RS232 Triggering and Serial Decode 25 When a data word value is selected for framing it is displayed in light blue When using 9 bit data words the 9th bit will also be displayed in light blue Decoded text is truncated at the end of the associated frame when there is insufficient space within frame boundaries Pink vertical bars indicate you need to expand the horizontal scale and run again to see decode When the horizontal scale setting does not permit the display of all available decoded data red dots will appear in the decoded bus to mark the location of hidden data Expand the horizontal scale to allow the data to display An unknown undefined bus is shown in red A parity error will cause the associated data word to be shown in red which includes the 5 8 data bits and the optional 9th bit UART RS232 Totalizer The UART RS232 totalizer consists of counters that provide a direct measure of bus quality and efficiency The totalizer appears on screen whenever UART RS232 Decode is ON in the Serial Decode Menu Serial Decode Menu Mode UART RAS232 The totalizer is running counting frames and calculating the percentage of error frames even when the oscilloscope is stopped not acquiring data The ERR error counter is a count of Rx and Tx frames with parity errors The TX FRAMES and RX FRAMES counts include both normal frames and frames with parity errors When an overflow c
143. eries with the input waveform that removes any DC offset voltage from the waveform Note that Channel Coupling is independent of Trigger Coupling To change trigger coupling see To select the trigger coupling on page 143 To specify bandwidth limiting 1 Press the desired channel key 2 Inthe Channel Menu press the BW Limit softkey to enable or disable bandwidth limiting When bandwidth limit is on the maximum bandwidth for the channel is approximately 20 MHz For waveforms with frequencies below this turning bandwidth limit on removes unwanted high frequency noise from the waveform The bandwidth limit also limits the trigger signal path of any channel that has BW Limit turned on To change the vertical scale knob s coarse fine adjustment setting 60 1 Push the channel s vertical scale knob or press the channel key and then the Fine softkey in the Channel Menu to toggle between fine and coarse adjustment of the vertical scale When Fine adjustment is selected you can change the channel s vertical sensitivity in smaller increments The channel sensitivity remains fully calibrated when Fine is on The vertical scale value is displayed in the status line at the top of the display When Fine is turned off turning the volts division knob changes the channel sensitivity in a 1 2 5 step sequence Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Vertical Controls 3 To invert a waveform 1 Press the de
144. ersistence to measure noise and jitter to see the worst case extremes of varying waveforms to look for timing violations or to capture events that occur infrequently Variable Persistence Results of previous acquisitions are erased after a certain amount of time Variable persistence gives you a view of acquired data that is similar to analog oscilloscopes When variable persistence is selected press the Time softkey and use the Entry knob to specify the amount of time that previous acquisitions are to be displayed The display will begin accumulating multiple acquisitions Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 109 8 Display Settings 3 To erase the results of previous acquisitions from the display press the Clear Persistence softkey The oscilloscope will start to accumulate acquisitions again 4 To return the oscilloscope to the normal display mode turn off persistence then press the Clear Persistence softkey Turning off persistence does not clear the display The display is cleared if you press the Clear Display softkey or if you press the AutoScale key which also turns off persistence For another method of seeing worst case extremes of varying waveforms see Glitch or Narrow Pulse Capture on page 156 To clear the display 1 Press Display gt Clear Display You can also configure the Quick Action key to clear the display See Configuring the Quick Action Key o
145. es User s Guide Triggers 10 100 05 a 2 05V KEYSIGHT YSI TECHNOLOGIES Acquisition Channels El a Pattern al 0 D 11100110 D Trigger Channel Pattern Pattern 0 0 sets the pattern to zero low on the selected channel A low is a voltage level that is less than the channel s trigger level or threshold level 1 sets the pattern to 1 high on the selected channel A high is a voltage level that is greater than the channel s trigger level or threshold level X sets the pattern to don t care on the selected channel Any channel set to don t care is ignored and is not used as part of the pattern However if all channels in the pattern are set to don t care the oscilloscope will not trigger The rising edge or falling edge softkey sets the pattern to an edge on the selected channel Only one rising or falling edge can be specified in the pattern When an edge is specified the oscilloscope will trigger at the edge specified if the pattern set for the other channels is true If no edge is specified the oscilloscope will trigger on the last edge that makes the pattern true Specifying an Edge in a Pattern You are allowed to specify only one rising or falling edge term in the pattern If you define an edge term then select a different channel in the pattern and define another edge term the previous edge definition is changed to a don t care Keysight InfiniiVision 2000 X Series Oscilloscope
146. events or segmented memory acquisitions See Navigating the Time Base on page 53 For more information see Chapter 2 Horizontal Controls starting on page 43 8 Run Control keys When the Run Stop key is green the oscilloscope is running that is acquiring data when trigger conditions are met To stop acquiring data press Run Stop When the Run Stop key is red data acquisition is stopped To start acquiring data press Run Stop To capture and display a single acquisition whether the oscilloscope is running or stopped press Single The Single key is yellow until the oscilloscope triggers For more information see Running Stopping and Making Single Acquisitions Run Control on page 149 9 Default Setup key Press this key to restore the oscilloscope s default settings details on Recall the Default Oscilloscope Setup on page 27 10 Auto Scale key When you press the AutoScale key the oscilloscope will quickly determine which channels have activity and it will turn these channels on and scale them to display the input signals See Use Auto Scale on page 28 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 33 1 34 Getting Started 11 Additional waveform controls The additional waveform controls consist of Math key provides access to math add subtract etc waveform functions See Chapter
147. ey and select a baud rate to match the signal in your device under test If the desired baud rate is not listed select User Defined on the Baud softkey then select the desired baud rate using the User Baud softkey You can set the UART baud rate from 1 2 kb s to 8 0000 Mb s in increments of 100 b s d Polarity Select idle low or idle high to match your device under test s state when at idle For RS232 select idle low e Bit Order Select whether the most significant bit MSB or the least significant bit LSB is presented after the start bit in the signal from your device under test For RS232 select LSB In the serial decode display the most significant bit is always displayed on the left regardless of how Bit Order is set 330 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide UART RS232 Triggering and Serial Decode 25 UART RS232 Triggering To set up the oscilloscope to capture UART RS 232 signals see Setup for UART RS232 Signals on page 329 To trigger on a UART Universal Asynchronous Receiver Transmitter signal connect the oscilloscope to the Rx and Tx lines and set up a trigger condition RS232 Recommended Standard 232 is one example of a UART protocol 1 2 Press Trigger In the Trigger Menu press the Trigger softkey then turn the Entry knob to select the serial slot Serial 1 on which the UART RS232 signals are being decoded Trigger Menu Trigger Trigger Setup w S UAR
148. f the channel s vertical scale and position knobs When disabled you can use the channel s vertical scale and position knobs normally Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 209 16 Digital Voltmeter 210 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Wavetorm Generator To select generated waveform types and settings 211 To output the waveform generator sync pulse 214 To specify the expected output load 214 To use waveform generator logic presets 215 To add noise to the waveform generator output 215 To add modulation to the waveform generator output 216 To restore waveform generator defaults 220 A waveform generator is built into the oscilloscope It is enabled by Option WGN or the DSOX2WAVEGEN upgrade The waveform generator gives you an easy way to provide input signals when testing circuitry with the oscilloscope Waveform generator settings can be saved and recalled with oscilloscope setups See Chapter 18 Save Recall Setups Screens Data starting on page 223 To select generated waveform types and settings 1 To access the Waveform Generator Menu and enable or disable the waveform generator output on the front panel Gen Out BNC press the Wave Gen key When waveform generator output is enabled the Wave Gen key is illuminated When waveform generator output is disabled the Wave Gen
149. ff External DE 40 000ns Era Auto 2 Inthe Trigger Mode and Coupling Menu press the External softkey External Trigger Menu 1 00 1 3 In the External Trigger Menu press the Units softkey to select between Volts for a voltage probe Amps for a current probe Measurement results channel sensitivity and the trigger level will reflect the measurement units you have selected 4 Press the Probe softkey then turn the entry knob to specify the probe attenuation The attenuation factor can be set from 0 1 1 to 1000 1 in a 1 2 5 sequence The probe attenuation factor must be set properly for measurements to be made correctly Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 147 11 Trigger Mode Coupling 148 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 12 Acquisition Control Running Stopping and Making Single Acquisitions Run Control 149 Overview of Sampling 150 Selecting the Acquisition Mode 155 Acquiring to Segmented Memory 161 This chapter shows how to use the oscilloscope s acquisition and run controls Running Stopping and Making Single Acquisitions Run Control There are two front panel keys for starting and stopping the oscilloscope s acquisition system Run Stop and Single KEYSIGHT TECHNOLOGIES When the Run Stop key is green the oscilloscope is running that is acquiri
150. form generator Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 213 17 Waveform Generator Waveform Generator Settings Menu Trig Out Triggers See To output the waveform generator sync pulse on page 214 To specify the expected output load on page 214 To use waveform generator logic presets on page 215 To restore waveform generator defaults on page 220 To output the waveform generator sync pulse 1 If the Waveform Generator Menu is not currently displayed on the oscilloscope s softkeys press the Wave Gen key 2 In the Waveform Generator Menu press the Settings softkey 3 In the Waveform Generator Settings Menu press the Trig Out softkey and turn the Entry knob to select Waveform Generator Sync Pulse Waveform Type Sync Signal Characteristics All waveforms except The Sync signal is a TTL positive pulse that occurs when the waveform DC and Noise rises above zero volts or the DC offset value DC N A Noise N A To specify the expected output load 1 If the Waveform Generator Menu is not currently displayed on the oscilloscope s softkeys press the Wave Gen key 2 In the Waveform Generator Menu press the Settings softkey 3 In the Waveform Generator Settings Menu press the Out Load softkey and turn the Entry knob to select 50 Q 214 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Waveform Generator 17 High Z The output impedance of
151. ftkey to go to the last segment Auto to play through segments in an automated fashion In the Auto play mode Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Horizontal Controls 2 Press the EQ 0 navigation keys to play backward stop or play forward in time You can press the or keys multiple times to speed up the playback There are three speed levels Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 55 2 Horizontal Controls 56 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls To turn waveforms on or off channel or math 58 To adjust the vertical scale 59 To adjust the vertical position 59 To specify channel coupling 59 To specify bandwidth limiting 60 To change the vertical scale knob s coarse fine adjustment setting 60 To invert a waveform 61 Setting Analog Channel Probe Options 61 The vertical controls include The vertical scale and position knobs for each analog channel The channel keys for turning a channel on or off and accessing the channel s softkey menu The following figure shows the Channel 1 Menu that appears after pressing the 1 channel key KEYSIGHT TECHNOLOGIES 57 3 Vertical Controls Channel Trigger Trigger level Volts div source __ or threshold i 100 05 Channels Channel 1 ground level
152. gate search events 54 To navigate segments 54 3 Vertical Controls To turn waveforms on or off channel or math 58 To adjust the vertical scale 59 To adjust the vertical position 59 To specify channel coupling 59 To specify bandwidth limiting 60 To change the vertical scale knob s coarse fine adjustment setting 60 To invert a waveform 61 Setting Analog Channel Probe Options 61 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide To specify the channel units 61 To specify the probe attenuation 62 To specify the probe skew 62 4 Math Waveforms To display math waveforms 65 To perform a transform function on an arithmetic operation 66 To adjust the math waveform scale and offset 67 Units for Math Waveforms 67 Math Operators 68 Add or Subtract 68 Multiply or Divide 69 Math Transforms 70 FFT Measurement 70 5 Reference Waveforms To save a waveform to a reference waveform location 79 To display a reference waveform 80 To scale and position reference waveforms 81 To adjust reference waveform skew 81 To display reference waveform information 82 To save recall reference waveform files to from a USB storage device 82 6 Digital Channels To connect the digital probes to the device under test 83 Probe cable for digital channels 84 Acquiring waveforms using the digital channels 87 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7
153. ger level to about 0 V The position of the trigger level for the analog channel is indicated by the trigger level icon Tp if the analog channel is on at the far left side of the display The value of the analog channel trigger level is displayed in the upper right corner of the display Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Triggers 10 The trigger level for a selected digital channel is set using the threshold menu in the Digital Channel Menu Press the Digital key on the front panel then press the Thresholds softkey to set the threshold level TTL CMOS ECL or user defined for the selected digital channel group The threshold value is displayed in the upper right corner of the display The line trigger level is not adjustable This trigger is synchronized with the power line supplied to the oscilloscope You can also change the trigger level of all channels by pressing Analyze gt Features and then selecting Trigger Levels Forcing a Trigger The Force Trigger key causes a trigger on anything and displays the acquisition This key is useful in the Normal trigger mode where acquisitions are made only when the trigger condition is met In this mode if no triggers are occurring that is the Trig d indicator is displayed you can press Force Trigger to force a trigger and see what the input signals look like n the Auto trigger mode when the trigger condition is not met triggers are for
154. gger output BNC connector See Setting the Rear Panel TRIG OUT connector Source on page 250 5 Calibration See To perform user calibration on page 251 protect button Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 39 1 Getting Started 6 EXT TRIG IN External trigger input BNC connector See External Trigger Input on connector page 146 for an explanation of this feature 8 USB Device This port is for connecting the oscilloscope to a host PC You can issue port remote commands from a host PC to the oscilloscope via the USB device port See Remote Programming with Keysight IO Libraries on page 268 7 USB Host port This port functions identically to the USB host port on the front panel USB Host Port is used for saving data from the oscilloscope and loading software updates See also USB Host port see page 36 Learn the Oscilloscope Display The oscilloscope display contains acquired waveforms setup information measurement results and the softkey definitions Analog channel Trigger point Delay Time Run Stop Trigger Trigger sensitivity _ time reference time div status type _ source s l N ee N wer Status line B 100 087 i E T Trigger level or digital threshold Trigger level _ Information area Analog channels and ground levels Cursors defining measurement N Measurements Menu line ities So
155. ght InfiniiVision 2000 X Series Oscilloscopes User s Guide Digital Channels 6 Passive probe input impedance is generally specified in terms of a parallel capacitance and resistance The resistance is the sum of the tip resistor value and the input resistance of the test instrument see the following figure The capacitance is the series combination of the tip compensating capacitor and the cable plus instrument capacitance in parallel with the stray tip capacitance to ground While this results in an input impedance specification that is an accurate model for DC and low frequencies the high frequency model of the probe input is more useful see the following figure This high frequency model takes into account pure tip capacitance to ground as well as series tip resistance and the cable s characteristic impedance Z 8 5 pF 100 kQ Figure 9 DC and Low Frequency Probe Equivalent Circuit 250 Q 7 5 pF 1 pF 100 kQ 150 Q Figure 10 High Frequency Probe Equivalent Circuit Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 95 6 96 Digital Channels The impedance plots for the two models are shown in these figures By comparing the two plots you can see that both the series tip resistor and the cable s characteristic impedance extend the input impedance significantly The stray tip capacitance which is generally small 1 pF sets the final break point on the impedance chart 100 k 10k High Freq
156. guration Metra Print to Options Network Setup Press to NETPRTO Invert Grat ae Print See To specify the print options on page 238 5 Press the Palette softkey to select the print palette See To specify the palette option on page 238 6 Press the Press to Print softkey You can stop printing by pressing the Cancel Print softkey The oscilloscope will print the last menu visited before you pressed the Print key Therefore if you have measurements Amplitude Frequency etc showing on the display before you press Print the measurements will be shown on the printout To print the display showing the Print Configuration Menu at the bottom press the Print key twice then press the Press to Print softkey You can also configure the Quick Action key to print the display See Configuring the Quick Action Key on page 256 See Also Adding an Annotation on page 257 To set up network printer connections When the DSOXLAN LAN VGA module is installed you can set up network printer connections A network printer is a printer attached to a computer or print server on the network 1 Press the Print key on the front panel 236 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Print Screens 19 2 In the Print Configuration Menu press the Print to softkey then turn the Entry knob to select the network printer you want to configure either 0 or 1 3 Press the Network Setup softkey
157. hannels including math and digital channels with up to seven waveforms for each digital pod When saving all segments the number of waveforms is equal to the number of active channels multiplied by the number of segments acquired Binary Data in MATLAB Binary data from an InfiniiVision oscilloscope can be imported to The MathWorks MATLAB You can download the appropriate MATLAB functions from the Keysight Technologies web site at www keysight com find 2000X Series examples Keysight provides the m files which need to be copied into the work directory for MATLAB The default work directory is C MATLAB work Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 285 22 Reference Binary Header Format File Header There is only one file header in a binary file The file header consists of the following information Waveform Header 286 Cookie Two byte characters AG that indicate the file is in the Keysight Binary Data file format Version Two bytes that represent the file version File Size A 32 bit integer that is the number of bytes that are in the file Number of A 32 bit integer that is the number of waveforms that are stored in the file Waveforms It is possible to store more than one waveform in the file and each waveform stored will have a waveform header When using segmented memory each segment is treated as a separate waveform The waveform header contains infor
158. he Entry knob to navigate to the file to recall See To navigate storage locations on page 230 Press the Press to Recall softkey A message indicating whether the recall was successful is displayed If you would like to clear the display of everything except the reference waveform press Clear Display Recalling Default Setups 1 Press the Save Recall key 232 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Save Recall Setups Screens Data 18 2 Inthe Save Recall Menu press Default Erase 3 In the Default Menu press one of these softkeys Default Setup recalls the oscilloscope s default setup This is the same as pressing the front panel Default Setup key See Recall the Default Oscilloscope Setup on page 27 Some user settings are not changed when recalling the default setup Factory Default recalls the oscilloscope s factory default settings You must confirm the recall because there are no user settings that are left unchanged Performing a Secure Erase 1 Press the Save Recall key 2 Inthe Save Recall Menu press Default Erase 3 In the Default menu press Secure Erase This performs a secure erase of all non volatile memory in compliance with National Industrial Security Program Operation Manual NISPOM Chapter 8 requirements You must confirm the secure erase and the oscilloscope will reboot when finished Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guid
159. he bottom of the display KEYSIGHT TECHNO IES Acquisition Channels 24 342 Channel Deselect Base D7 DO Binary Bus values can be shown in hex or binary To read the digital bus value at any point using the cursors 1 Turn on Cursors by pressing the Cursors key on the front panel 2 Press the cursor Mode softkey and change the mode to Hex or Binary 3 Press the Source softkey and select Bus1 or Bus2 4 Use the Entry knob and the X1 and X2 softkeys to position the cursors where you want to read the bus values Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Digital Channels 6 20 005 Auto gt a 2 08V X1 cursor KEYSICHT Acquisition X2 cursor Bus values Source Cursors X O000us Bus1 X2 f Set cursors Select Bus1 Bus values mode to or Bus2 source at cursors Binary or Hex shown here When you press the Digital key to display the Digital Channel Menu the digital activity indicator is shown where the cursor values were and the bus values at the cursors are displayed in the graticule Bus valuesare The bus values are also displayed when using the Pattern trigger function Press displayed when the Pattern key on the front panel to display the Pattern Trigger Menu and the bus using Pattern values will be displayed on the right above the softkeys tri ngger The dollar sign will be displayed in the bus value when the bus value cannot be displayed as a he
160. he display indicates the time reference point The horizontal scale knob works in the Normal time mode while acquisitions are running or when they are stopped When running adjusting the horizontal scale knob changes the sample rate When stopped adjusting the horizontal scale knob lets you zoom into acquired data See Panning and Zooming Single or Stopped Acquisitions on page 46 Note that the horizontal scale knob has a different purpose in the Zoom display See To display the zoomed time base on page 50 To adjust the horizontal delay position 1 Turn the horizontal delay position knob 4 The trigger point moves horizontally pausing at 0 00 s mimicking a mechanical detent and the delay value is displayed in the status line Changing the delay time moves the trigger point solid inverted triangle horizontally and indicates how far it is from the time reference point hollow inverted triangle V These reference points are indicated along the top of the display grid Figure 2 shows the trigger point with the delay time set to 200 us The delay time number tells you how far the time reference point is located from the trigger point When delay time is set to zero the delay time indicator overlays the time reference indicator All events displayed left of the trigger point happened before the trigger occurred These events are called pre trigger information and they show events that led up to the trigger point
161. he external pa trigger input This includes the digital channels if connected Auto Scale finds turns on and scales any channel with a repetitive waveform that has a frequency of at least 25 Hz a duty cycle greater than 0 5 and an amplitude of at least 10 mV peak to peak Any channels that do not meet these requirements are turned off The trigger source is selected by looking for the first valid waveform starting with external trigger then continuing with the lowest number analog channel up to the highest number analog channel and finally if digital probes are connected the highest number digital channel During Auto Scale the delay is set to 0 0 seconds the horizontal time div sweep speed setting is a function of the input signal about 2 periods of the triggered signal on the screen and the triggering mode is set to Edge Passive Probes Each oscilloscope passive probe must be compensated to match the input characteristics of the oscilloscope channel to which it is connected A poorly compensated probe can introduce significant measurement errors 1 Input the Probe Comp signal see Input a Waveform on page 27 2 Press Default Setup to recall the default oscilloscope setup see Recall the Default Oscilloscope Setup on page 27 3 Press Auto Scale to automatically configure the oscilloscope for the Probe Comp signal see Use Auto Scale on page 28 4 Press the channel key to which the probe is co
162. he first clock edge as defined rising or falling seen after the CS or CS signal transitions from low to high or high to low is the first clock in the serial stream Chip Select Press the CS or CS softkey then turn the Entry knob to select the channel that is connected to the SPI frame line The label CS or CS for the source channel is automatically set The data pattern and the clock transition must occur during the time when the framing signal is valid The framing signal must be valid for the entire data pattern If the framing signal is set to Timeout the oscilloscope generates it s own internal framing signal after it sees inactivity on the serial clock line Clock Timeout Select Clock Timeout in the Frame by softkey then select the Timeout softkey and turn the Entry knob to set the minimum time that the Clock signal must be idle not transitioning before the oscilloscope will search for the Data pattern on which to trigger The Timeout value can be set anywhere from 100 ns to 10s When you press the Frame by softkey the Display Info graphic changes to show timeout selection or the current state of the chip select signal b Press the Threshold softkey then turn the Entry knob to select the chip select signal threshold voltage level The threshold voltage level is used in decoding and it will become the trigger level when the trigger type is set to the selected serial decode slot When Display Info
163. he second one is designated usb2 See Also Chapter 18 Save Recall Setups Screens Data starting on page 223 Setting Oscilloscope Preferences The User Preferences Menu under Utility gt Options gt Preferences lets you specify oscilloscope preferences To choose expand about center or ground on page 247 To disable enable transparent backgrounds on page 248 To load the default label library on page 248 To set up the screen saver on page 248 To set AutoScale preferences on page 249 To choose expand about center or ground When you change a channel s volts division setting the waveform display can be set to expand or compress about the signal ground level or the center of the display To set the waveform expansion reference point 1 Press Utility gt Options gt Preferences gt Expand and select Ground The displayed waveform will expand about the position of the channel s ground This is the default setting The ground level of the signal is identified by the position of the ground level icon at the far left side of the display The ground level will not move when you adjust the vertical sensitivity volts division control Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 247 20 Utility Settings 248 If the ground level is off screen the waveform will expand about the top or bottom edge of the screen based on where the ground is off screen Center
164. he source channel is automatically set Press the Threshold softkey then turn the Entry knob to select the clock signal threshold voltage level The threshold voltage level is used in decoding and it will become the trigger level when the trigger type is set to the selected serial decode slot Press the slope softkey 4 t to select rising edge or falling edge for the selected Clock source This determines which clock edge the oscilloscope will use to latch the serial data When Display Info is enabled the graphic changes to show the current state of the clock signal 6 Press the MOSI softkey to open the SPI Master Out Slave In Menu SPI Master Out Slave In Menu MOSI Data Threshold Display Info 1 44V In the SPI Master Out Slave In Menu a Press the MOSI Data softkey then turn the Entry knob to select the channel that is connected to a SPI serial data line If the channel you selected is off switch it on The MOSI label for the source channel is automatically set Press the Threshold softkey then turn the Entry knob to select the MOSI signal threshold voltage level Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide I2C SPI Triggering and Serial Decode 24 The threshold voltage level is used in decoding and it will become the trigger level when the trigger type is set to the selected serial decode slot 7 Optional Press the MISO softkey to open the SPI Master In Slave Out Menu
165. he whole screen Press the Center softkey then turn the Entry knob to set the desired center frequency of the display Scale lets you set your own vertical scale factors for FFT expressed in dB div decibels division See To adjust the math waveform scale and offset on page 67 Offset lets you set your own offset for the FFT The offset value is in dB and is represented by the center horizontal grid line of the display See To adjust the math waveform scale and offset on page 67 More FFT displays the More FFT Settings Menu 2 Press the More FFT softkey to display additional FFT settings FFT Resolution 763Hz Auto Setup Window selects a window to apply to your FFT input signal Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 4 72 Math Waveforms Hanning window for making accurate frequency measurements or for resolving two frequencies that are close together Flat Top window for making accurate amplitude measurements of frequency peaks Rectangular good frequency resolution and amplitude accuracy but use only where there will be no leakage effects Use on self windowing waveforms such as pseudo random noise impulses sine bursts and decaying sinusoids Blackman Harris window reduces time resolution compared to a rectangular window but improves the capacity to detect smaller impulses due to lower secondary lobes Vertical Units lets you select
166. hen using segmented memory use the Analyze Segments feature see Infinite Persistence with Segmented Memory on page 163 to show infinite persistence across all acquired segments See also To set or clear persistence on page 109 for details 1 Set up a trigger condition See Chapter 10 Triggers starting on page 119 for details 2 Press the Acquire key in the Waveform section of the front panel 3 Press the Segmented softkey 4 In the Segmented Memory Menu press the Segmented softkey to enable segmented memory acquisitions 5 Press the of Segs softkey and turn the Entry knob to select the number of segments into which you would like to divide the oscilloscope s memory Memory can be divided into as few as two segments and as many as 25 segments Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 161 12 Acquisition Control 162 6 Press the Run or Single key The oscilloscope runs and fills a memory segment for each trigger event When the oscilloscope is busy acquiring multiple segments the progress is displayed in the upper right area of the display The oscilloscope continues to trigger until memory is filled then the oscilloscope stops If the signal you are measuring has more than about 1 s of inactivity consider selecting the Normal trigger mode to prevent AutoTriggering See To select the Auto or Normal trigger mode on page 142 1 0002 Progress indicator Sample rate
167. ic setup 87 AutoScale preferences 249 AutoScale digital channels 87 AutoScale undo 28 Average Full Screen measurement 183 Average N Cycles measurement 183 averaging acquire mode 155 158 159 B Back Up key 31 bandwidth 254 bandwidth limit 60 bandwidth required oscilloscope 154 bandwidth oscilloscope 151 Base measurement 181 BIN file format 224 binary data bin 284 binary data file examples 288 binary data in MATLAB 285 binary data example program for reading 288 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide bits SPI trigger 323 Blackman Harris FFT window 72 blanking 49 BMP file format 224 brick wall frequency response 152 brightness of waveforms 31 Browser Web Control 263 264 265 266 267 Browser Based Remote Front Panel 266 built in help 41 burst capture signal bursts 161 bus display mode 91 buttons keys front panel 30 BW Limit in DVM display 208 C calibration 251 calibration protect button 38 39 calibration status 273 CAN decode source channels 296 CAN frame counter 301 CAN serial decode 298 CAN totalizer 301 CAN trigger 297 capture signal bursts 161 Center FFT 71 channel labels 113 channel analog 57 channel bandwidth limit 60 channel coupling 59 channel invert 61 channel on off keys 35 channel position 59 channel probe units 61 channel skew 62 channel vernier 60 channel vertical se
168. ide Licensed Options Available Reference 22 Many of the following licensed options can be easily installed without returning the oscilloscope to a Service Center Not all options can be installed on all models See data sheets for details Table9 Licensed Options Available License Description After purchase model number notes AUTO Automotive Serial Triggering and Analysis CAN LIN Order DSOX2AUTO COMP Computer Serial Triggering and Analysis Order DSOX2COMP RS232 422 485 UART Provides trigger and decode capability for many UART Universal Asynchronous Receiver Transmitter protocols including RS232 Recommended Standard 232 DVM Digital Voltmeter Order DSOXDVM Provides provides 3 digit voltage and 5 digit frequency measurements using any analog channel EDK Educator s Kit Order DSOXEDK Provides training signals on the oscilloscope s Demo terminals and a lab guide tutorial for education environments EMBD Embedded Serial Triggering and Analysis 12C SPI Order DSOX2EMBD MASK Mask Limit Test Order DSOX2MASK Lets you create a mask and test waveforms to determine whether they comply to the mask mem4M Memory Upgrade Order DSOX2MEMUP It shows the total memory depth 4 Mpts interleaved MSO Mixed Signal Oscilloscope MSO Upgrade a DSO to an MSO Order DSOX2MSO Adds 8 digital channels You do not have to install any The digital probe cable kit is supplied with hard ware the MSO licens
169. ilar message to indicate that the measurement may not be reliable Press the Type softkey then rotate the Entry knob to select a measurement to be made SRT BO0 08 a af Average Full Screen MEMAN Measurements gii Period Pk Pk 1 gt TL Frequency Measurement Menu Source Settings Clear Meas Measurement Ess ES For more information on the types of measurements see Measurements Summary on page 177 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Measurements 14 4 The Settings softkey will be available to make additional measurement settings on some measurements ol Press the Add Measurement softkey or push the Entry knob to display the measurement 6 To turn off measurements press the Meas key again Measurements are erased from the display 7 To stop making one or more measurements press the Clear Meas softkey and choose the measurement to clear or press Clear All urements Menu gi Clear After all measurements have been cleared when Meas is pressed again the default measurements will be Frequency and Peak Peak Measurements Summary The automatic measurements provided by the oscilloscope are listed in the following table All measurements are available for analog channel waveforms All measurements except Counter are available for math waveforms other than FFT A limited set of measurements is available for math FFT waveforms and for digital channel wavefor
170. ile 245 Demo 1 terminal 36 Demo 2 terminal 36 depth AM modulation 217 deviation FM modulation 219 DHCP 243 244 differential probes 281 Digit softkey 126 digital bus mode 91 digital channel controls 34 digital channel inputs 36 digital channel menu 89 digital channels 89 digital channels AutoScale 87 digital channels enabling 284 digital channels logic threshold 90 digital channels probing 94 digital channels size 89 digital display interpreting 88 digital probes 83 94 digital probes impedance 94 digital voltmeter DVM 207 Display key 35 display multiple acquisitions 150 display area 41 display interpreting 40 display persistence 109 display signal detail 107 display softkey labels 41 display status line 41 displayed channels AutoScale 249 distortion problems 71 Divide math function 69 DNS IP 243 Duty cycle measurement 188 DVM digital voltmeter 207 DVM license 283 Dynamic DNS 243 E ECL threshold 90 edge speeds 154 edge triggering 121 EDK license 283 EEPROM data read I2C trigger 313 either edge trigger 123 EMBD license 283 English user interface and Quick Help 42 Entry knob 32 Entry knob push to select 32 erase secure 233 event table 102 expand about 59 247 expand about center 248 expand about ground 247 exporting waveform 223 EXT TRIG IN as Z axis input 49 EXT TRIG IN connector 40 external memory device 36
171. in the library the new label will not be put in the library For example if label AO is in the library and you make a new label called A12345 the new label is not added to the library When you save a new user defined label the new label will replace the oldest label in the list Oldest is defined as the longest time since the label was last assigned to a channel Any time you assign any label to a channel that label will move to the newest in the list Thus after you use the label list for a while your labels will predominate making it easier to customize the instrument display for your needs When you reset the label library list see next topic all of your custom labels will be deleted and the label list will be returned to its factory configuration To reset the label library to the factory default Pressing the Default Library softkey will remove all user defined labels from the library and set the labels back to the factory default Once deleted these user defined labels cannot be recovered 1 Press Utility gt Options gt Preferences 2 Press the Default Library softkey This will delete all user defined labels from the library and set the labels in the library back to the factory default However this does not default the labels currently assigned to the channels those labels that appear in the waveform area Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 117 9 Labels Defaulting labels withou
172. ine at the top of the display Each major horizontal division in the grid corresponds to the time div shown in the status line at the top of the display To freeze the display To freeze the display without stopping running acquisitions you must configure the Quick Action key See Configuring the Quick Action Key on page 256 1 Once the Quick Action key has been configured press it to freeze the display 2 To un freeze the display press Quick Action again Manual cursors can be used on the frozen display Many activities such as adjusting the trigger level adjusting vertical or horizontal settings or saving data will un freeze the display Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 111 8 Display Settings 112 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 9 Labels To turn the label display on or off 113 To assign a predefined label to achannel 114 To define a new label 115 To load a list of labels from a text file you create 116 To reset the label library to the factory default 117 You can define labels and assign them to each analog input channel or you can turn labels off to increase the waveform display area Labels can also be applied to digital channels on MSO models To turn the label display on or off 1 Press the Label key on the front panel This turns on labels for the
173. initiated by Run Stop the process repeats If the acquisition was initiated by pressing Single the acquisition stops and you can Pan and Zoom the waveform In either Auto or Normal trigger mode a trigger may be missed if the event occurs while the pre trigger buffer is being filled This may be more likely for example when the horizontal scale knob is set to a slow time div setting such as 500 ms div The trigger indicator at the top right of the display shows whether triggers are occurring In the Auto trigger mode the trigger indicator can show Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Trigger Mode Coupling 11 Auto flashing the trigger condition is not found after the pre trigger buffer has filled and forced triggers and acquisitions are occurring Auto not flashing the trigger condition is found or the pre trigger buffer is being filled In the Normal trigger mode the trigger indicator can show Trig d flashing the trigger condition is not found after the pre trigger buffer has filled and no acquisitions are occurring Trig d not flashing trigger condition is found or pre trigger buffer is being filled When the oscilloscope is not running the trigger indicator area shows Stop When to Use Auto The Auto trigger mode is appropriate when Trigger Mode Checking DC signals or signals with unknown levels or activity When trigge
174. ion Menu Annotation Text Color Background Inverted See Also To save BMP or PNG image files on page 225 To print the oscilloscope s display on page 235 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 259 20 Utility Settings 260 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface Accessing the Web Interface 262 Browser Web Control 263 Save Recall 269 Get Image 271 Identification Function 272 Instrument Utilities 272 Setting a Password 274 When the Keysight InfiniiVision X Series oscilloscopes have the DSOXLAN LAN VGA option module installed you can access the oscilloscope s built in web server using a Java enabled web browser The oscilloscope s web interface lets you View information about the oscilloscope like its model number serial number host name IP address and VISA address connect string Control the oscilloscope using the Remote Front Panel Send SCPI Standard Commands for Programmable Instrumentation remote programming commands via the SCPI Commands applet window Save setups screen images waveform data and mask files Recall setup files reference waveform data files or mask files Get screen images and save or print them from the browser Activate the Identification function to identify a particular instrument by causing a message to be displayed or a front
175. ion module is installed interfaces The Keysight IO Libraries Suite connectivity software to enables communication over these interfaces You can download the Keysight IO Libraries Suite from www keysight com find iolib Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Save Recall Web Interface 21 Information about controlling the oscilloscope through remote commands is contained in the Programmer s Guide which is included on the documentation CD supplied with this oscilloscope You can also access this document on the Keysight web site For more information about connecting to the oscilloscope refer to the Keysight Technologies USB LAN GPIB Interfaces Connectivity Guide For a printable electronic copy of the Connectivity Guide direct your Web browser to www keysight com and search for Connectivity Guide You can save setup files screen images waveform data files or mask files to your PC via the oscilloscope s web interface see Saving Files via the Web Interface on page 269 You can recall setup files reference waveform data files or mask files from your PC via the oscilloscope s web interface see Recalling Files via the Web Interface on page 270 Saving Files via the Web Interface To save setup files screen images waveform data Lister data or mask files to your PC via the oscilloscope s web interface 1 Access the oscilloscope s web interface see Accessing the Web Interface o
176. is the mode most common value of the upper part of the waveform or if the mode is not well defined the top is the same as Maximum The Y cursor shows the value being measured See Also To isolate a pulse for Top measurement on page 181 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Measurements 14 To isolate a pulse for Top measurement The following figure shows how to use Zoom mode to isolate a pulse for a Top measurement You may need to change the measurement window setting so that the measurement is made in the lower Zoom window See Measurement Window with Zoom Display on page 193 1 000 10 00 Channels Measurements Top 1 Measurement Menu Source y d Settings Clear Meas A Figure 33 Isolating area for Top measurement Base The Base of a waveform is the mode most common value of the lower part of the waveform or if the mode is not well defined the base is the same as Minimum The Y cursor shows the value being measured Overshoot Overshoot is distortion that follows a major edge transition expressed as a percentage of Amplitude The X cursors show which edge is being measured edge closest to the trigger reference point Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 181 14 Measurements 182 local Maximum D Top 4 Amplitude i Rising edge overshoot Base D local Minimum x 100 Falling edge overshoot Amplitude Overshoot
177. ist sampling theorem states that for a limited bandwidth band limited signal with maximum frequency fmax the equally spaced sampling frequency fs must be greater than twice the maximum frequency fmax in order to have the signal be uniquely reconstructed without aliasing fmax fo 2 Nyquist frequency fy folding frequency Aliasing Aliasing occurs when signals are under sampled fg lt 2f yay Aliasing is the signal distortion caused by low frequencies falsely reconstructed from an insufficient number of sample points Figure 21 Aliasing Oscilloscope Bandwidth and Sample Rate An oscilloscope s bandwidth is typically described as the lowest frequency at which input signal sine waves are attenuated by 3 dB 30 amplitude error Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 151 12 Acquisition Control At the oscilloscope bandwidth sampling theory says the required sample rate is fs 2fgw However the theory assumes there are no frequency components above fmax fay in this case and it requires a system with an ideal brick wall frequency response OdB 3dB c 2 w gt c oO E lt fn fs FE QUENCY ma Figure 22 Theoretical Brick Wall Frequency Response However digital signals have frequency components above the fundamental frequency square waves are made up of sine waves at the fundamental frequency and an infinite number of odd harmonics and typically for 500 MHz bandwidths and below
178. it does not operate on channels that are not displayed To enable mask test order Option LMT at time of oscilloscope purchase or order DSOX2MASK as a stand alone item after oscilloscope purchase To create a mask from a golden waveform Automask A golden waveform meets all chosen parameters and it is the waveform to which all others will be compared 1 Configure the oscilloscope to display the golden waveform 2 Press the Analyze key 3 Press Features then select Mask Test 4 Press Features again to enable mask testing KEYSIGHT TECHNOLOGIES 195 15 Mask Testing 196 Failures Channel 1 O Features Automask w 5 Press Automask In the Automask Menu press the Source softkey and ensure the desired analog channel is selected Automask Menu Source Units Create Divisions 0 10 0 10 Mask Adjust the mask s horizontal tolerance Y and vertical tolerance X These are adjustable in graticule divisions or in absolute units volts or seconds selectable using the Units softkey Press the Create Mask softkey The mask is created and testing begins Whenever the Create Mask softkey is pressed the old mask is erased and a new mask is created Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Mask Testing 15 77505 2 0005 Channels Curr Si ate Create Divisions 0 10 ERS 9 Toclear the mask and switch off mask testing press the Back Up key to return to the Mask
179. itivity so that the input signal is near full screen but not clipped Use the Flat Set the FFT sensitivity to a sensitive range such as 2 dB division op window For best frequency accuracy on peaks Use the Hanning window Use Cursors to place an X cursor on the frequency of interest Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Math Waveforms 4 Adjust frequency span for better cursor placement Return to the Cursors Menu to fine tune the X cursor For more information on the use of FFTs please refer to Keysight Application Note 243 The Fundamentals of Signal Analysis at http literature cdn keysight com litweb pdf 5952 8898E pdf Additional information can be obtained from Chapter 4 of the book Spectrum and Network Measurements by Robert A Witte FFT Units O dBV is the amplitude of a 1 Vrms sinusoid When the FFT source is channel 1 or channel 2 or channel 3 or 4 on 4 channel models FFT units will be displayed in dBV when channel units is set to Volts and channel impedance is set to 1 MQ FFT units will be displayed in dBm when channel units is set to Volts and channel impedance is set to 50Q FFT units will be displayed as dB for all other FFT sources or when a source channel s units has been set to Amps FFT DC Value The FFT computation produces a DC value that is incorrect It does not take the offset at center screen into account The DC value is not corrected in order to a
180. ity indicator To change the displayed size of the digital channels 1 Press the Digital key 2 Press the size n M JL softkey to select how the digital channels are displayed The sizing control lets you spread out or compress the digital traces vertically on the display for more convenient viewing To switch a single channel on or off 1 With the Digital Channel Menu displayed rotate the Entry knob to select the desired channel from the popup menu 2 Push the Entry knob or press the softkey that is directly below the popup menu to switch the selected channel on or off To switch all digital channels on or off 1 Press the Digital key to toggle the display of digital channels The Digital Channel Menu is displayed above the softkeys If you want to switch the digital channels off and the Digital Channel Menu is not already displayed you must push the Digital key twice to switch the digital channels off The first push displays the Digital Channel Menu and the second push switches the channels off Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 89 6 To switch groups of channels on or off 1 Press the Digital key on the front panel if the Digital Channel Menu is not already displayed 2 Press the Turn off or Turn on softkey for the D7 DO group Each time you press the softkey the softkey s mode toggles between Turn on and Turn off To change the logic threshold for digital channels 9
181. ject HF Reject adds a 50 kHz low pass filter in the trigger path to remove high frequency components from the trigger waveform 3 dB DC 50 kHz You can use HF Reject to remove high frequency noise such as AM or FM broadcast stations or noise from fast system clocks from the trigger path 1 Press the Mode Coupling key 2 Inthe Trigger Mode and Coupling Menu press the HF Reject softkey to enable or disable To set the trigger holdoff Trigger holdoff sets the amount of time the oscilloscope waits after a trigger before re arming the trigger circuitry Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 145 11 Trigger Mode Coupling Trigger Holdoff Operating Hints Use the holdoff to trigger on repetitive waveforms that have multiple edges or other events between waveform repetitions You can also use holdoff to trigger on the first edge of a burst when you know the minimum time between bursts For example to get a stable trigger on the repetitive pulse burst shown below set the holdoff time to be gt 200 ns but lt 600 ns Holdoff Oscilloscope triggers here H gt gt gt gt gt a gt gt 200 ns 600 ns To set the trigger holdoff 1 Press the Mode Coupling key 2 Inthe Trigger Mode and Coupling Menu press the Holdoff softkey then turn the Entry knob to increase or decrease the trigger holdoff time The correct holdoff
182. k edge if all bits in the pattern match Frame Start Ad dress7 Read Ack Data Ack Data2 finds a read frame on the 26th clock edge if all bits in the pattern match Frame Start Ad dress7 Write Ack Data Ack Data2 finds a write frame on the 26th clock edge if all bits in the pattern match For more information on searching data see Searching Lister Data on page 104 For more information on using the Navigate key and controls see Navigating the Time Base on page 53 Setup for SPI Signals Serial Peripheral Interface SPI signals setup consists of connecting the oscilloscope to a clock MOSI data MISO data and framing signal then setting the threshold voltage level for each input channel and finally specifying any other signal parameters To set up the oscilloscope to capture SPI signals use the Signals softkey which appears in the Serial Decode Menu 1 Press Label to turn on labels 2 Press Serial 3 Press the Mode softkey then select SPI trigger type 4 Press the Signals softkey to open the SPI Signals Menu Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 319 24 320 12C SPI Triggering and Serial Decode SPI Signals Menu Clock MOSI N Display Info w w SPI Clock Menu Clock Threshold Display Info 1 444 In the SPI Clock Menu a Press the Clock softkey then turn the Entry knob to select the channel connected to the SPI serial clock line The CLK label for t
183. k files can be saved to internal oscilloscope memory or to a USB storage device and recalled later You can also recall default or factory default setups Oscilloscope screen images can be saved to a USB storage device in BMP or PNG formats Acquired waveform data can be saved to a USB storage device in comma separated value CSV ASCII XY and binary BIN formats There is also a command to securely erase all the oscilloscope s non volatile internal memory Saving Setups Screen Images or Data 1 Press the Save Recall key 2 Inthe Save Recall Menu press Save 3 In the Save Trace and Setup Menu press Format then turn the Entry knob to select the type of file you want to save KEYSIGHT TECHNOLOGIES 223 18 Save Recall Setups Screens Data 224 Setup scp The oscilloscope s horizontal timebase vertical sensitivity trigger mode trigger level measurements cursors and math function settings that tell the oscilloscope how to make a particular measurement See To save setup files on page 225 8 bit Bitmap image bmp The complete screen image in a reduced color 8 bit bitmap format See To save BMP or PNG image files on page 225 24 bit Bitmap image bmp The complete screen image in a 24 bit color bitmap format See To save BMP or PNG image files on page 225 24 bit image png The complete screen image in a 24 bit color PNG format that uses lossless compression Files are
184. key then turn the Entry knob to select the acquisition mode The InfiniiVision oscilloscopes have the following acquisition modes Normal at slower time div settings normal decimation occurs and there is no averaging Use this mode for most waveforms See Normal Acquisition Mode on page 156 Peak Detect at slower time div settings the maximum and minimum samples in the effective sample period are stored Use this mode for displaying narrow pulses that occur infrequently See Peak Detect Acquisition Mode on page 156 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 155 12 Acquisition Control 156 Averaging at all time div settings the specified number of triggers are averaged together Use this mode for reducing noise and increasing resolution of periodic signals without bandwidth or rise time degradation See Averaging Acquisition Mode on page 158 High Resolution at slower time div settings all samples in the effective sample period are averaged and the average value is stored Use this mode for reducing random noise See High Resolution Acquisition Mode on page 160 Normal Acquisition Mode In Normal mode at slower time div settings extra samples are decimated in other words some are thrown away This mode yields the best display for most waveforms Peak Detect Acquisition Mode See Also In Peak Detect mode at slower time div settings when decimation would normall
185. key and select rising edge falling edge alternating edges or either edge depending on the selected source The selected slope is displayed in the upper right corner of the display Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Using AutoScale to Set Up Edge Triggers Triggers 10 200 05 2 21V KEYSIGHT TECHN S Acquisition Channels Source Alternating edge mode is useful when you want to trigger on both edges of a clock for example DDR signals Either edge mode is useful when you want to trigger on any activity of a selected source All modes operate up to the bandwidth of the oscilloscope except Either edge mode which has a limitation Either edge mode will trigger on Constant Wave signals up to 100 MHz but can trigger on isolated pulses down to 1 2 oscilloscope s bandwidth The easiest way to set up an Edge trigger on a waveform is to use AutoScale Simply press the AutoScale key and the oscilloscope will attempt to trigger on the waveform using a simple Edge trigger type See Use Auto Scale on page 28 MegaZoom Technology Simplifies Triggering With the built in MegaZoom technology you can simply AutoScale the waveforms then stop the oscilloscope to capture a waveform You can then pan and zoom through the data using the Horizontal and Vertical knobs to find a stable trigger point AutoScale often produces a triggered display Keysight InfiniiVision 2000 X Series Oscilloscopes U
186. l key then the Signals softkey Serial Decode Options Keysight s hardware accelerated serial decode options can be installed when the oscilloscope is manufactured or added later The following serial decode licenses are available With the DSOX2AUTO license you can decode CAN Controller Area Network and LIN Local Interconnect Network serial buses See CAN Serial Decode on page 298 LIN Serial Decode on page 306 KEYSIGHT TECHNOLOGIES 101 7 Serial Decode Lister 102 With the DSOX2EMBD license you can decode 12C Inter IC and SPI Serial Peripheral Interface serial buses See I2C Serial Decode on page 316 SPI Serial Decode on page 324 With the DSOX2COMP license you can decode many UART Universal Asynchronous Receiver Transmitter protocols including RS232 Recommended Standard 232 See UART RS232 Serial Decode on page 333 To determine whether these licenses are installed on your oscilloscope see To display oscilloscope information on page 254 To order serial decode licenses go to www keysight com and search for the product number for example DSOX2AUTO or contact your local Keysight Technologies representative see www keysight com find contactus Lister is a powerful tool for investigating protocol failures You can use Lister to view large amounts of packet level serial data in a tabular format including time tags and specific decoded values After pressing the
187. l module slot GPIB interface when a GPIB module is installed in the rear panel module slot To configure the I O interfaces 1 On the oscilloscope s front panel press Utility 2 Inthe Utility Menu press 1 0 3 In the I O Menu press Configure KEYSIGHT TECHNOLOGIES 241 20 Utility Settings LAN When a DSOXLAN LAN VGA module is installed you can use the LAN Settings and LAN Reset softkeys to configure the LAN interface See Setting up the Oscilloscope s LAN Connection on page 242 GPIB When a DSOXGPIB GPIB module is installed you can use the Address softkey to configure the GPIB address There are no configuration settings for the USB interface When an I O interface is installed remote control over that interface is always enabled Also the oscilloscope can be controlled via multiple 1 0 interfaces for example USB and LAN at the same time See Also Chapter 21 Web Interface starting on page 261 when the oscilloscope is connected to a LAN Remote Programming via the Web Interface on page 267 The oscilloscope s Programmer s Guide Remote Programming with Keysight IO Libraries on page 268 Setting up the Oscilloscope s LAN Connection When the DSOXLAN LAN VGA module is installed you can place the oscilloscope on the network and set up its LAN connection Once that is done you can use the oscilloscope s web interface or remotely control the oscilloscope via the LAN interface The
188. ll Delete Character Use the Spell and Delete Character softkeys to enter the annotation text Spell press this softkey and turn the Entry knob to select the character at the current position press this softkey to enter characters and move the cursor to the next character position gt press this softkey to enter characters and move the cursor to the previous character position Delete Character press the or softkeys until the desired character is highlighted then press this softkey to delete the character You can use a connected USB keyboard instead of using the Spell and other character editing softkeys Use the Clear softkey to delete all annotation characters Press OK to save the annotation edits 258 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Utility Settings 20 6 Press the Text Color softkey and turn the Entry knob to select the annotation color You can choose white red or colors that match analog channels digital channels math waveforms reference waveforms or markers 7 Press the Background softkey and turn the Entry knob to select the annotation background Opaque the annotation has a solid background Inverted the annotation s foreground and background colors are switched Transparent the annotation has a transparent background 1 5005 500 08 Trig d 1 70 KEYSIGHT TECHNOLO S Acquisition Channels Annotat
189. lloscopes User s Guide 215 17 Waveform Generator 2 In the Waveform Generator Menu press the Settings softkey 3 In the Waveform Generator Settings Menu press the Add Noise softkey and turn the Entry knob to select the amount of white noise to add to the waveform generator output Note that adding noise affects edge triggering on the waveform generator source see Edge Trigger on page 121 as well as the waveform generator sync pulse output signal which can be sent to TRIG OUT see Setting the Rear Panel TRIG OUT Source on page 250 This is because the trigger comparator is located after the noise source To add modulation to the waveform generator output 216 Modulation is where an original carrier signal is modified according to the amplitude of a second modulating signal The modulation type AM FM or FSK specifies how the carrier signal is modified To enable and set up modulation for the waveform generator output 1 Ifthe Waveform Generator Menu is not currently displayed on the oscilloscope s softkeys press the Wave Gen key 2 Inthe Waveform Generator Menu press the Settings softkey 3 In the Waveform Generator Settings Menu press the Modulation softkey 4 In the Waveform Generator Modulation Menu Waveform Generator Modulation Menu Modulation ype Waveform AM Freq AM Depth Symmetry 50 Ramp 10kHz 100 Press the Modulation softkey to enable or disable modulated waveform generator output You can en
190. ls x Measurements PKPRI easurement Menu Source Type Settings Clear Meas c n hot Me gt w You can also configure the Quick Action key to display the Snapshot All popup See Configuring the Quick Action Key on page 256 Voltage Measurements The following figure shows the voltage measurement points Maximum Measurement units for each input channel can be set to Volts or Amps using the channel Probe Units softkey See To specify the channel units on page 61 The units of math waveforms are described in Units for Math Waveforms on page 67 Peak Peak on page 180 Maximum on page 180 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 179 14 Measurements 180 Minimum on page 180 Amplitude on page 180 Top on page 180 Base on page 181 Overshoot on page 181 Preshoot on page 183 Average on page 183 DC RMS on page 184 AC RMS on page 184 Peak Peak The peak to peak value is the difference between Maximum and Minimum values The Y cursors show the values being measured Maximum Maximum is the highest value in the waveform display The Y cursor shows the value being measured Minimum Minimum is the lowest value in the waveform display The Y cursor shows the value being measured Amplitude The Amplitude of a waveform is the difference between its Top and Base values The Y cursors show the values being measured Top The Top of a waveform
191. m controls 4 Entry knob 3 Intensity key 12 Measure controls 2 Softkeys Te 5 13 Waveform keys 14 File keys 1 Power switch N oe a ss 15 Help key 21 Waveform 20 Digital 19 USB 18 Demo 2 Ground 17 Analog 16 Vertical controls generator channel Host and Demo 1 channel output inputs port terminals inputs 1 Power switch Press once to switch power on press again to switch power off See Power On the Oscilloscope on page 25 2 Softkeys The functions of these keys change based upon the menus shown on the display directly above the keys The S Back Up key moves up in the softkey menu hierarchy At the top of the hierarchy the 8 Back Up key turns the menus off and oscilloscope information is shown instead 3 Intensity key Press the key to illuminate it When illuminated turn the Entry knob to adjust waveform intensity You can vary the intensity control to bring out signal detail much like an analog oscilloscope Digital channel waveform intensity is not adjustable More details about using the Intensity control to view signal detail are on To adjust waveform intensity on page 107 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 1 32 Getting Started Entry knob The Entry knob is used to select items from menus and to change values The function of the Entry knob changes based upon the current menu and softkey sele
192. mage files 225 To save CSV ASCII XY or BIN data files 226 Length Control 227 To save Lister datafiles 228 To save reference waveform files to a USB storage device 229 To save masks 229 To navigate storage locations 230 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide To enter filenames 230 Recalling Setups Masks or Reference Waveforms 231 To recall setup files 231 To recall mask files 232 To recall reference waveform files from a USB storage device 232 Recalling Default Setups 232 Performing a Secure Erase 233 19 Print Screens To print the oscilloscope s display 235 To set up network printer connections 236 To specify the print options 238 To specify the palette option 238 20 Utility Settings 1 0 Interface Settings 241 Setting up the Oscilloscope s LAN Connection 242 To establish aLAN connection 243 Stand alone Point to Point Connection toaPC 244 File Explorer 245 Setting Oscilloscope Preferences 247 To choose expand about center or ground 247 To disable enable transparent backgrounds 248 To load the default label library 248 To set up the screensaver 248 To set AutoScale preferences 249 Setting the Oscilloscope s Clock 250 Setting the Rear Panel TRIG OUT Source 250 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 21 Web Interface Performing Service Tasks 251 To perform user calibration 251 To perf
193. mation about the type of waveform data that is stored following the waveform data header Header Size A 32 bit integer that is the number of bytes in the header Waveform Type A 32 bit integer that is the type of waveform stored in the file 0 Unknown 1 Normal 2 Peak Detect 3 Average 4 Not used in InfiniiVision oscilloscopes 5 Not used in InfiniiVision oscilloscopes 6 Logic Number of A 32 bit integer that is the number of waveform buffers required to read the Waveform data Buffers Points A 32 bit integer that is the number of waveform points in the data Count A 32 bit integer that is the number of hits at each time bucket in the waveform record when the waveform was created using an acquisition mode like averaging For example when averaging a count of four would mean every waveform data point in the waveform record has been averaged at least four times The default value is 0 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Reference 22 X Display Range A 32 bit float that is the X axis duration of the waveform that is displayed For time domain waveforms it is the duration of time across the display If the value is zero then no data has been acquired X Display Origin A 64 bit double that is the X axis value at the left edge of the display For time domain waveforms it is the time at the start of the display This value is treated as a do
194. mp or 24 bit image png 2 Press the softkey in the second position and use the Entry knob to navigate to the save location See To navigate storage locations on page 230 3 Press the Settings softkey In the File Settings Menu you have these softkeys and options Setup Info setup information vertical horizontal trigger acquisition math and display settings is also saved in a separate file with a TXT extension Invert Grat the graticule in the image file has a white background instead of the black backgound that appears on screen Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 225 18 Save Recall Setups Screens Data Aptos N Graticule Not Inverted Graticule Inverted Palette lets you choose between Color or Grayscale images 4 Finally press the Press to Save softkey A message indicating whether the save was successful is displayed When saving screen images the oscilloscope uses the last menu visited before pressing the Save Recall key This lets you save any relevant information within the softkey menu area To save a screen image showing the Save Recall Menu at the bottom press the Save Recall key twice before saving the image You can also save the oscilloscope s display image using a web browser See Get Image on page 271 for details See Also Adding an Annotation on page 257 To save CSV ASCII XY or BIN data files Data files can be saved to a
195. ms as described in the following table Measurement i Valid for Digital Channels Snapshot All on page 178 Amplitude on page 180 Average on page 183 Yes Full Screen Base on page 181 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 177 14 Measurements Measurement Delay on page 189 Valid for Digital Channels Notes Measures between two sources Press Settings to specify the second source Duty Cycle on page 188 Yes Fall Time on page 188 Frequency on page 187 Yes Maximum on page 180 Yes Minimum on page 180 Yes Overshoot on page 181 Peak Peak on page 180 Yes Period on page 186 Yes Phase on page 190 Measures between two sources Press Settings to specify the second source Preshoot on page 183 Rise Time on page 188 DC RMS on page 184 AC RMS on page 184 Top on page 180 Width on page 188 Yes Width on page 188 Yes Use the cursors to make other measurements on FFT Snapshot All The Snapshot All measurement type displays a popup containing a snapshot of all 178 the single waveform measurements Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Measurements 14 1 00 1 00 500 05 KEYSIGHT TECH Acquisition Channe
196. much smaller than the BMP format See To save BMP or PNG image files on page 225 CSV data csv This creates a file of comma separated values of all displayed channels and math waveforms This format is suitable for spreadsheet analysis See To save CSV ASCII XY or BIN data files on page 226 ASCII XY data csv This creates separate files of comma separated values for each displayed channel This format is also suitable for spreadsheets See To save CSV ASCII XY or BIN data files on page 226 Reference Waveform data h5 Saves waveform data in a format that can be recalled to one of the oscilloscope s reference waveform locations See To save reference waveform files to a USB storage device on page 229 Multi Channel Waveform data h5 Saves multiple channels of waveform data in a format that can be opened by the N8900A InfiniiView oscilloscope analysis software You can recall the first Analog or Math channel from a multi channel waveform data file Binary data bin This creates a binary file with a header and data in the form of time and voltage pairs This file is much smaller than the ASCII XY data file See To save CSV ASCII XY or BIN data files on page 226 Lister data csv This is a CSV format file containing serial decode row information with commas separating the columns See To save Lister data files on page 228 Mask msk This creates a mask file in
197. n page 262 2 When the oscilloscope s web interface Welcome Page is displayed select the Identification on radio button An Identify message is displayed on the oscilloscope you can either select Identification off or press the OK softkey on the oscilloscope to continue Support Products Keysight Site TECHNOLOGIES Welcome to your LK 1 Web Enabled Oscilloscope MSO X 2024A AW KEYSIGHT PETES SS Information about this Web Enabled Instrument Serial Number US50210029 Agilent agate cage sion 141 121 237 192 a mx2024a 10029 vate 141 121 237 192 TCPIPO 141 121 237 192 INSTR id Advanced information Identification off on Identification option Use the navigation bar on the leftto access your oscilloscope and related PI Slices Instrument Utilities The Instrument Utilities page of the web interface lets you View installed options View firmware versions 272 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Install firmware upgrade files View calibration status You can select these cababilities via a drop down menu TECHNOLOGIES KEYSIGHT Oscilloscope Instrument Utilities Installed Options v Installed Options Firmware Version Calibration Status talled Options Web Interface 21 MSO Instrument ue Utilities EMBD AUTO COMP SGM MASK BW20 BW10 EDK S SCPIPS MSO Acq Memory Max Embedded serial decode and trigger
198. n page 262 2 When the oscilloscope s web interface is displayed select the Save Recall tab from the left side of the Welcome screen 3 Click the Save link 4 On the Save page a Enter the name of the file you are saving to b Select the format Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 269 21 Web Interface KEYSIGHT TECHNOLOGIES Another web from Keysig Oscilloscope EH Contral ekai 8 bit Bitmap image bmp Save Recall 24 bit Bitmap image bmp SAR PNG 24 bit image png e CSV data csv ASCII XY data csv et mage Reference Waveform data n5 Multi Channel Waveform data n5 Binary data bin Instrument Lister data csv RS etra Mask msk OOO You can click Preview to view the oscilloscope s current screen image When previewing you can use the New Acquisition check box to force a new acquisition before the preview With some formats you can click Save Setup Info to save setup information to an ASCII txt format file c Click Save The current acquisition is saved d Inthe File Download dialog click Save e Inthe Save As dialog navigate to the folder where you want to save the file then click Save Recalling Files via the Web Interface To recall setup files reference waveform data files or mask files from your PC via the oscilloscope s web interface 1 Access the oscilloscope s web interface see Accessing the Web
199. n external USB storage device 1 Press Save Recall gt Save gt Format then turn the Entry knob to select CSV data csv ASCII XY data csv or Binary data bin 2 Press the softkey in the second position and use the Entry knob to navigate to the save location See To navigate storage locations on page 230 3 Press the Settings softkey In the File Settings Menu you have these softkeys and options Setup Info when enabled setup information vertical horizontal trigger acquisition math and display settings is also saved in a separate file with a TXT extension 226 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Save Recall Setups Screens Data 18 Length sets the number of data points that will be output to the file For more information see Length Control on page 227 Save Seg when data is acquired to segmented memory you can specify whether the currently displayed segment is saved or all acquired segments are saved See also Saving Data from Segmented Memory on page 163 4 Finally press the Press to Save softkey A message indicating whether the save was successful is displayed See Also Binary Data bin Format on page 284 CSV and ASCII XY files on page 291 Minimum and Maximum Values in CSV Files on page 292 Length Control The Length control is available when saving data to CSV ASCII XY or BIN format files It sets the number of data point
200. n greater detail Place the desired part of the waveform at the center of the screen and decrease frequency span to increase the display resolution As frequency span is decreased the number of points shown is reduced and the display is magnified a While the FFT spectrum is displayed use the Math and Cursors keys to switch between measurement functions and frequency domain controls in FFT Menu FFT Resolution The FFT resolution is the quotient of the sampling rate and the number of FFT points fs N With a fixed number of FFT points up to 65 536 the lower the sampling rate the better the resolution Decreasing the effective sampling rate by selecting a greater time div setting will increase the low frequency resolution of the FFT display and also increase the chance that an alias will be displayed The resolution of the FFT is the effective sample rate divided by the number of points in the FFT The actual resolution of the display will not be this fine as the shape of the window will be the actual limiting factor in the FFTs ability to resolve two closely space frequencies A good way to test the ability of the FFT to resolve two closely spaced frequencies is to examine the sidebands of an amplitude modulated sine wave For the best vertical accuracy on peak measurements Make sure the probe attenuation is set correctly The probe attenuation is set from the Channel Menu if the operand is a channel Set the source sens
201. n page 256 To select the grid type When the Video trigger type is selected see Video Trigger on page 129 and the vertical scaling of at least one displayed channel is 140 mV div the Grid softkey lets you select from these grid types Full the normal oscilloscope grid mV shows vertical grids labeled on the left from 0 3 V to 0 8 V IRE Institute of Radio Engineers shows vertical grids in IRE units labeled on the left from 40 to 100 IRE The 0 35 V and 0 7 V levels from the mV grid are also shown and labeled at the right When the IRE grid is selected cursor values are also shown in IRE units Cursor values via the remote interface are not in IRE units The mV and IRE grid values are accurate and match Y cursor values when the vertical scaling is 140 mV division and the vertical offset is 245 mV To select the grid type 110 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Display Settings 8 1 Press Display 2 Press the Grid softkey then turn the Entry knob a to select the grid type To adjust the grid intensity To adjust the display grid graticule intensity 1 Press Display 2 Press the Intensity softkey then turn the Entry knob a to change the intensity of the displayed grid The intensity level is shown in the Intensity softkey and is adjustable from O to 100 Each major vertical division in the grid corresponds to the vertical sensitivity shown in the status l
202. n the Text line above the softkeys Text AGILENT TECHNOLOGIES Saver Wait a Preview User 180min Spell A 3 Press the Wait softkey then turn the Entry knob to select the number of minutes to wait before the selected screen saver activates When you turn the Entry knob the number of minutes is displayed on the Wait softkey The default time is 180 minutes 3 hours 4 Press the Preview softkey to preview the screen saver you have selected with the Saver softkey 5 To view the normal display after the screen saver has started press any key or turn any knob To set AutoScale preferences 1 Press Utility gt Options gt Preferences gt AutoScale 2 Inthe AutoScale Preferences Menu you can Press the Fast Debug softkey enable disable this type of autoscale When fast debug is enabled autoscale lets you make quick visual comparisons to determine whether the signal being probed is a DC voltage ground or an active AC signal Channel coupling is maintained to allow easy viewing of oscillating signals Press the Channels softkey and turn the Entry knob to specify the channels to be autoscaled All Channels The next time you press AutoScale all channels that meet the requirements of AutoScale will be displayed Only Displayed Channels The next time you press AutoScale only the channels that are turned on will be examined for signal activity This is useful if you only want to view specific active chann
203. n the first error is detected on the first waveform that does not conform to the mask This setting supersedes the Minimum of Tests and Minimum Time settings Save The oscilloscope saves the screen image when an error is detected In the Save Menu press Save Recall gt Save select an image format bmp or png destination on a USB storage device and file name which can be auto incrementing If errors occur too frequently and the oscilloscope spends all its time saving images press the Stop key to stop acquisitions Print The oscilloscope prints the screen image when an error is detected This option is only available when a printer is connected as described in To print the oscilloscope s display on page 235 Measure Measurements and measurement statistics if your oscilloscope supports them run only on waveforms that contain a mask violation Measurements are not affected by passing waveforms This mode is not available when the acquisition mode is set to Averaging Note that you can choose to Print or Save but you cannot select both at the same time All other actions may be selected at the same time For example you can select both Stop and Measure to cause the oscilloscope to measure and stop on the first error You can also output a signal on the rear panel TRIG OUT BNC connector when there is a mask test failure See Setting the Rear Panel TRIG OUT Source on page 250 Source Lock Whe
204. n time dt the common mode voltage may increase to a level that causes false data generation Probe 1 lt 4 Zin iy L GND Probe Vn Common Mode Ground 4 co hitlari Probe 2 lt 4 Zin Probe N lt Zin O Figure12 Common Mode Input Voltage Model In addition to the common mode voltage longer ground returns also degrade the pulse fidelity of the probe system Rise time is increased and ringing due to the undamped LC circuit at the input of the probe is also increased Because the Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 97 6 Digital Channels digital channels display reconstructed waveforms they do not show ringing and perturbations You will not find ground problems through examination of the waveform display In fact it is likely you will discover the problem through random glitches or inconsistent data measurements Use the analog channels to view ringing and perturbations Best Probing Practices Because of the variables L di and dt you may be unsure how much margin is available in your measurement setup The following are guidelines for good probing practices The ground lead from each digital channel group D15 D8 and D7 D0 should be attached to the ground of the device under test if any channel within the group is being used for data capture When capturing data in a noisy environment every third digital chan
205. n trigger ona stop start condition a restart a missing acknowledge an EEPROM data read or on a read write frame with a specific device address and data value 1 Press Trigger then select the I2C trigger type 2 Press Trigger 3 In the Trigger Menu press the Trigger softkey then turn the Entry knob to select the serial slot Serial 1 on which the 1 C signals are being decoded Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide I2C SPI Triggering and Serial Decode 24 Trigger on ddress Jata Data2 jead 7 2 0x29 OxXX OxKX 4 Press the Trigger softkey then turn the Entry knob to select the trigger condition Start Condition The oscilloscope triggers when SDA data transitions from high to low while the SCL clock is high For triggering purposes including frame triggers a restart is treated as a start condition Stop Condition The oscilloscope triggers when data SDA transitions from low to high while the clock SCL is high soa NAT TT NIDO nA 1 i I 1 scL 1 7 8 _ 9 1 7 _ 8 9 f71 Sy i t bam ii Jol j ees Start Address R Ack Data Ack Stop Condition Condition Missing Acknowledge The oscilloscope triggers when SDA data is high during any Ack SCL clock bit Address with no Ack The oscilloscope triggers when the acknowledge of the selected address field is false The R W bit is ignored Restart The oscilloscope triggers when another start condition occurs before
206. n you turn on Source Lock using the Source Lock softkey the mask is redrawn to match the source whenever you move the waveform For example if you change the horizontal timebase or the vertical gain the mask is redrawn with the new settings When you turn off Source Lock the mask is not redrawn when horizontal or vertical settings are changed Source If you change the Source channel the mask is not erased It is re scaled to the vertical gain and offset settings of the channel to which it is assigned To create a new mask for the selected source channel go back up in the menu hierarchy then press Automask and press Create Mask The Source softkey in the Mask Setup Menu is the same as the Source softkey in the Automask Menu Test All When enabled all displayed analog channels are included in the mask test When disabled just the selected source channel is included in the test Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 199 15 Mask Testing Mask Statistics From the Mask Test Menu press the Statistics softkey to enter the Mask Statistics Menu 7 750 Channels Transparent Clear Display Show Stats When you enable Show Statistics the following information is displayed Current mask name of mask Channel number date and time of Tests total number of mask tests executed Status Passing Failing or Untested Accumulated test time in hours minutes seconds and te
207. ncy can be adjusted from 100 mHz to 100 kHz Symmetry represents the amount of time per cycle that the ramp waveform is rising and can be adjusted from 0 to 100 Pulse Use the Frequency Frequency Fine Period Period Fine Amplitude High Level Offset Low Level and Wid th Wid th Fine softkeys to set the pulse signal parameters The frequency can be adjusted from 100 mHz to 10 MHz The pulse width can be adjusted from 20 ns to the period minus 20 ns DC Use the Offset softkey to set the DC level Noise Use the Amplitude High Level and Offset Low Level to set the noise signal parameters For all waveform types the output amplitude into 50 Q can be adjusted from 10 mVpp to 2 5 Vpp or from 20 mVpp to 5 Vpp into an open circuit load Pressing a signal parameter softkey can open a menu for selecting the type of adjustment For example you can choose to enter amplitude and offset values or you can choose to enter high level and low level values Or you can choose to enter frequency values or period values Keep pressing the softkey to select the type of adjustment Turn the Entry knob to adjust the value Notice that you can select between coarse and fine adjustments for frequency period and width Also pushing the Entry knob is a quick way to toggle between coarse and fine adjustments The Settings softkey opens the Waveform Generator Settings Menu which lets you make other settings related to the wave
208. ndicated by an X highlighted in red if an error Aliased data is highlighted in pink When this happens decrease the horizontal time div setting and run again Searching for I2C Data in the Lister The oscilloscope s search capability lets you search for and mark certain types of 2C data in the Lister You can use the Navigate key and controls to navigate through the marked rows 1 With 12C selected as the serial decode mode press Search 2 Inthe Search Menu press the Search softkey then turn the Entry knob to select the serial slot Serial 1 or Serial 2 on which the 12C signal is being decoded 318 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide I2C SPI Triggering and Serial Decode 24 3 Press Search then select from these options Missing Acknowledge finds SDA data is high during any Ack SCL clock bit Address with no Ack finds when the acknowledge of the selected address field is false The R W bit is ignored Restart finds when another start condition occurs before a stop condition EEPROM Data Read finds EEPROM control byte value 1010xxx on the SDA line followed by a Read bit and an Ack bit It then looks for the data value and qualifier set by the Data is softkey and the Data softkeys Frame Start Ad dress7 Read Ack Data finds a read frame on the 17th clock edge if all bits in the pattern match Frame Start Ad dress7 Write Ack Data finds a write frame on the 17th cloc
209. nel Probe Menu press Skew then select the desired skew value Each analog channel can be adjusted 100 ns in 10 ps increments for a total of 200 ns difference The skew setting is not affected by pressing Default Setup or Auto Scale Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 63 3 Vertical Controls 64 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 4 Math Waveforms To display math waveforms 65 To perform a transform function on an arithmetic operation 66 To adjust the math waveform scale and offset 67 Units for Math Waveforms 67 Math Operators 68 Math Transforms 70 Math functions can be performed on analog channels The resulting math waveform is displayed in light purple You can use a math function on a channel even if you choose not to display the channel on screen You can Perform an arithmetic operation like add subtract or multiply on analog input channels Perform a transform function like FFT on an analog input channel Perform a transform function on the result of an arithmetic operation To display math waveforms 1 Press the Math key on the front panel to display the Waveform Math Menu Waveform Math Menu f t Ch1 Ch2 Function Operator Source 1 fit KEYSIGHT TECHNOLOGIES 65 4 Math Waveforms TIP 2 If f t is not already shown on the Function
210. nel probe s ground should be used in addition to the channel group s ground High speed timing measurements rise time lt 3 ns should make use of each digital channel probe s own ground When designing a high speed digital system you should consider designing dedicated test ports that interface directly to the instrument s probe system This will ease measurement setup and ensure a repeatable method for obtaining test data The 01650 61607 16 channel logic probe cable and the 01650 63203 termination adapter are designed to make it easy to connect to industry standard 20 pin board connectors The cable is a 2 m logic analyzer probe cable and the termination adapter provides the proper RC networks in a very convenient package These parts as well as the 1251 8106 20 pin low profile straight board connector can be ordered from Keysight Technologies To replace digital probe leads If you need to remove a probe lead from the cable insert a paper clip or other small pointed object into the side of the cable assembly and push to release the latch while pulling out the probe lead 98 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Digital Channels 6 Table 3 Digital Probe Replacement Parts Part Number Description N6459 60001 Digital probe kit contains N6459 61601 8 channel cable 01650 82103 2 inch probe grounds qty 3 and 5090 4832 grabbers qty 10 N6459 61601 8 channel cable with 8
211. nfiniiVision 2000 X Series Oscilloscopes User s Guide Acquisition Control 12 The higher the number of averages the slower the displayed waveform responds to waveform changes You must compromise between how quickly the waveform responds to changes and how much you want to reduce the displayed noise on the signal To use the Averaging mode 1 Press the Acquire key then press the Acq Mode softkey until the Averaging mode is selected 2 Press the Avgs softkey and turn the Entry knob to set the number of averages that best eliminates the noise from the displayed waveform The number of acquisitions being averaged is displayed in the Avgs softkey 200 05 Channels Acquire Menu Acq Mode Segmented Normal Figure 26 Random noise on the displayed waveform Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 159 12 Acquisition Control 160 Segmented w Figure 27 128 Averages used to reduce random noise See Also Chapter 11 Tr igger Mode Coupling starting on page 141 High Resolution Acquisition Mode 1469 KEYSIGHT TECHNO IES Acquisition ng Channels In High Resolution mode at slower time div settings extra samples are averaged in order to reduce random noise produce a smoother trace on the screen and effectively increase vertical resolution High Resolution m ode averages sequential sample points withi n the same acquisition An extra bit of vertical resolution i
212. ng data when trigger conditions are met To stop acquiring data press Run Stop When stopped the last acquired waveform is displayed When the Run Stop key is red data acquisition is stopped Stop is displayed next to the trigger type in the status line at the top of the display To start acquiring data press Run Stop To capture and display a single acquisition whether the oscilloscope is running or stopped press Single The Single run control lets you view single shot events without subsequent waveform data overwriting the display Use Single when you want maximum memory depth for pan and zoom 149 12 Acquisition Control When you press Single the display is cleared the trigger mode is temporarily set to Normal to keep the oscilloscope from auto triggering immediately the trigger circuitry is armed the Single key is illuminated and the oscilloscope waits until a trigger condition occurs before it displays a waveform When the oscilloscope triggers the single acquisition is displayed and the oscilloscope is stopped the Run Stop key is illuminated in red Press Single again to acquire another waveform If the oscilloscope doesn t trigger you can press the Force Trigger key to trigger on anything and make a single acquisition To display the results of multiple acquisitions use persistence See To set or clear persistence on page 109 Single vs Running The maximum data record l
213. nnected 1 2 etc 5 In the Channel Menu press Probe 6 Inthe Channel Probe Menu press Probe Check then follow the instructions on screen If necessary use a nonmetallic tool supplied with the probe to adjust the trimmer capacitor on the probe for the flattest pulse possible Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 29 1 Getting Started On the N2862 63 90 probes the trimmer capacitor is the yellow adjustment on the probe tip On other probes the trimmer capacitor is located on the probe BNC connector Perfectly compensated Over compensated Under compensated XS XN 7 Connect probes to all other oscilloscope channels channel 2 of a 2 channel oscilloscope or channels 2 3 and 4 of a 4 channel oscilloscope 8 Repeat the procedure for each channel Learn the Front Panel Controls and Connectors On the front panel key refers to any key button you can press Softkey specifically refers to the six keys that are directly below the display The legend for these keys is directly above them on the display Their functions change as you navigate through the oscilloscope s menus For the following figure refer to the numbered descriptions in the table that follows 30 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Getting Started 1 5 Tools keys 6 Trigger controls 7 Horizontal controls 8 Run Control keys 11 Additional wavefor
214. not have to be turned on to have a label assigned to it If the channel is turned on its current label will be highlighted 3 Press the Spell softkey then turn the Entry knob to select the first character in the new label Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 115 9 Labels Label Assignment Auto Increment Turning the Entry knob selects a character to enter into the highlighted position shown in the New label line above the softkeys and in the Spell softkey Labels can be up to ten characters in length 4 Press the Enter softkey to enter the selected character and to go to the next character position 5 You may position the highlight on any character in the label name by successively pressing the Enter softkey 6 To delete a character from the label press the Enter softkey until the letter you want to delete is highlighted then press the Delete Character softkey You can use a connected USB keyboard instead of using the Spell and other character editing softkeys 7 When you are done entering characters for the label press the Apply New Label softkey to assign the label to the selected channel When you define a new label it is added to the nonvolatile label list When you assign a label ending in a digit such as ADDRO or DATAO the oscilloscope automatically increments the digit and displays the modified label in the New label field after you press the Apply New Label softkey Theref
215. nsitivity 59 characteristics 277 choosing values 32 cleaning 255 339 Index clear display 158 clear display Quick Clear Display 257 clear persistence 110 clock 250 CMOS threshold 90 COMP license 283 compensate passive probes 29 36 Config softkey 243 244 connect probes digital 83 connection toa PC 244 connectors rear panel 38 control remote 241 controls front panel 30 copyright 2 counter CAN frame 301 counter UART RS232 frame 335 coupling channel 59 coupling trigger 143 crosstalk problems 71 CSV file format 224 CSV files minimum and maximum values 292 current probes 281 cursor measurements 165 cursor units 167 Cursors key 35 Cursors knob 35 cursors binary 166 cursors hex 167 cursors manual 166 cursors track waveform 166 D D 34 91 damage shipping 21 data sheet 277 DC channel coupling 60 DC RMS Full Screen measurement 184 DC RMS N Cycles measurement 184 DC signals checking 143 DC waveform generator output 213 dead time re arm 163 decibels FFT vertical units 72 decimating samples 155 decimation for measurement record 292 decimation for screen 292 340 default configuration 27 default label library 117 default setup 27 233 Default Setup key 33 defaults waveform generator 220 delay knob 45 Delay measurement 178 189 delay time indicator 52 delayed sweep 50 delete character 230 delete f
216. nths of seconds And for each analog channel Number of failures acquisitions in which the signal excursion went beyond the mask Failure rate percentage of failures Sigma the ratio of process sigma to maximum achievable sigma based on number of waveforms tested 200 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Mask Testing 15 Reset Statistics Note that statistics are also reset when Mask Test is switched on after being switched off Clear Mask softkey is pressed An Automask is created Additionally the accumulated time counter is reset whenever the oscilloscope is run after the acquisition was stopped Transparent Enable Transparent mode to write measurement values and statistics on the screen without a background Disable the Transparent mode to show them with a gray background The Transparent setting affects mask test statistics measurement statistics and reference waveform information display Clear Display Clears acquisition data from the oscilloscope display To manually modify a mask file You can manually modify a mask file that you created using the Automask function 1 Follow the steps 1 7 in To create a mask from a golden waveform Automask on page 195 Do not clear the mask after creating it ao oO FF OON Attach a USB mass storage device to the oscilloscope Press the Save Recall key Press the Save softkey Pre
217. ntrols and connectors 30 front panel self test 254 front panel browser based remote 266 front panel language overlay 37 front panel real scope remote 264 front panel simple remote 265 FSK frequency shift keying modulation waveform generator output 219 G g t 66 gateway IP 243 Gaussian frequency response 152 German front panel overlays 38 German user interface and Quick Help 42 glitch capture 156 glitch trigger 126 golden waveform test 195 GPIB address 242 GPIB interface remote control 241 GPIB module 24 39 GPIB module installation 24 grabber 85 86 graphical user interface language 42 graticule intensity 111 graticule type 110 grid intensity 111 grid type 110 ground level 58 Ground terminal 36 H Hanning FFT window 72 hardware self test 254 Help key 35 help built in 41 hex bus trigger 126 Hex softkey 126 HF Reject 145 high frequency noise rejection 145 high resolution mode 155 160 holdoff 145 hop frequency FSK modulation 220 Horiz key 33 43 48 50 158 Horizontal controls 33 46 horizontal Navigate key 33 horizontal position control 33 horizontal position knob 45 horizontal scale fine adjustment 51 horizontal Search key 33 horizontal sweep speed control 33 horizontal time div control 33 horizontal Zoom key 33 host name 243 261 Host name softkey 244 1 0 interface settings 241 12C serial decode 316 12C trigger
218. odule ng the module in place The LAN VGA or GPIB module must be installed before powering on the oscilloscope Tilt the Oscilloscope for Easy Viewing 24 There are tabs under the oscilloscope s front feet that ca oscilloscope Keysight InfiniiVision 2000 X Seri n be flipped out to tilt the es Oscilloscopes User s Guide Getting Started 1 Flip Out Tabs Power On the Oscilloscope Power Line voltage frequency and power Requirements Line 100 120 Vac 50 60 400 Hz 100 240 Vac 50 60 Hz 100 W max Ventilation The air intake and exhaust areas must be free from obstructions Unrestricted air Requirements flow is required for proper cooling Always ensure that the air intake and exhaust areas are free from obstructions The fan draws air in from the left side and bottom of the oscilloscope and pushes it out behind the oscilloscope When using the oscilloscope in a bench top setting provide at least 2 clearance at the sides and 4 100 mm clearance above and behind the oscilloscope for proper cooling Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 25 1 Getting Started To power on the oscilloscope 1 Connect the power cord to the rear of the oscilloscope then to a suitable AC voltage source Route the power cord so the oscilloscope s feet and legs do not pinch the cord 2 The oscilloscope automatically adj
219. ondition occurs the counter displays OVERFLOW The counters can be reset to zero by pressing the Reset UART Counters softkey in the UART RS232 Settings Menu Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 335 25 UART RS232 Triggering and Serial Decode Interpreting UART RS232 Lister Data 1 0003 Stop 1 12V KEYSIGHT TECHNOLOGIES Acquisition 210 8ms Zoom to Options Selection Zoom w In addition to the standard Time column the UART RS232 Lister contains these columns Rx receive data Tx transmit data Errors highlighted in red Parity Error or Unknown Error Aliased data is highlighted in pink When this happens decrease the horizontal time div setting and run again Searching for UART RS232 Data in the Lister The oscilloscope s search capability lets you search for and mark certain types of UART RS232 data in the Lister You can use the Navigate key and controls to navigate through the marked rows 1 With UART RS232 selected as the serial decode mode press Search 2 Inthe Search Menu press the Search softkey then turn the Entry knob to select the serial slot Serial 1 or Serial 2 on which the UART RS232 signals are being decoded 3 In the Search Menu press Search then select from these options 336 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide UART RS232 Triggering and Serial Decode 25 Rx Data Finds a data byte
220. onitor Optional GPIB module A Quick Help system is built into the oscilloscope Press and hold any key to display Quick Help Complete instructions for using the quick help system are given in Access the Built In Quick Help on page 41 For more information about InfiniiVision oscilloscopes see www keysight com find scope Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide In This Guide This guide shows how to use the InfiniiVision 2000 X Series oscilloscopes When unpacking and using the oscilloscope for the first time see Chapter 1 Getting Started starting on page 21 When displaying waveforms and acquired data see Chapter 2 Horizontal Controls starting on page 43 Chapter 3 Vertical Controls starting on page 57 Chapter 4 Math Waveforms starting on page 65 Chapter 5 Reference Waveforms starting on page 79 Chapter 6 Digital Channels starting on page 83 Chapter 7 Serial Decode starting on page 101 Chapter 8 Display Settings starting on page 107 Chapter 9 Labels starting on page 113 When setting up triggers or changing how data is acquired see Chapter 10 Triggers starting on page 119 Chapter 11 Trigger Mode Coupling starting on page 141 Chapter 12 Acquisition Control starting on page 149 Making measurements and analyzing data Chapter 13 Cursors starting on page 165 Chapter 1
221. or gt BW Limit appears in the DVM display to caution you about rs inaccura To use the digital volt te RMS measurement results meter 1 Press the Analyze key Press Features then select Digital Voltmeter 2 3 Press Features again to enable the DVM measurements 4 Press the Source softkey and turn the Entry knob to select the analog channel on which digital vo tmeter DVM measurements are made The selected channel does not have to be on displaying a waveform in order for DVM measurem ents to be made 5 Press the Mode softkey and turn the Entry knob to select the digital voltmeter DVM mode AC RMS displays the root mean square value of the acquired data with the DC component removed DC displays th DC RMS displa Frequency disp e DC value of the acquired data ys the root mean square value of the acquired data lays the frequency counter measurement Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Digital Voltmeter 16 6 Press Transparent to toggle between a transparent and shaded background for the DVM display 7 Ifthe selected source channel is not used in oscilloscope triggering press Auto Range to disable or enable automatic adjustment of the DVM channel s vertical scale vertical ground level position and trigger threshold voltage level used for the counter frequency measurement When enabled Auto Range overrides attempted adjustments o
222. or and mark certain types of LIN data in the Lister You can use the Navigate key and controls to navigate through the marked rows 1 With LIN selected as the serial decode mode press Search 2 Inthe Search Menu press the Search softkey then turn the Entry knob to select the serial slot Serial 1 or Serial 2 on which the LIN signal is being decoded 3 Press Search then select from these options ID Finds frames with the specified ID Press the Frame ID softkey to select the ID ID amp Data Finds frames with the specified ID and data Press the Frame ID softkey to select the ID Press the Bits softkey to enter the data value Errors Finds all errors For more information on searching data see Searching Lister Data on page 104 For more information on using the Navigate key and controls see Navigating the Time Base on page 53 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 24 2C SPI Triggering and serial Decode Setup for I2C Signals 311 12C Triggering 312 12C Serial Decode 316 Setup for SPI Signals 319 SPI Triggering 323 SPI Serial Decode 324 I2C SPI triggering and serial decode requires Option EMBD or the DSOX3EMBD upgrade NOTE Only one SPI serial bus can be decoded at a time Setup for I2C Signals I2C Inter IC bus signals setup consists of connecting the oscilloscope to the serial
223. or entering a few commands interactively When creating automated programs for controlling the oscilloscope you will typically use the Keysight IO Libraries from within a programming environment like Microsoft Visual Studio see Remote Programming with Keysight IO Libraries on page 268 Real Scope Remote Front Panel To operate the oscilloscope using the web interface s Real Scope Remote Front Panel 1 Access the oscilloscope s web interface see Accessing the Web Interface on page 262 2 When the oscilloscope s web interface is displayed select Browser Web Control then select Real Scope Remote Front Panel After a few seconds the Remote Front Panel appears 3 Click keys or knobs that you would normally press on the oscilloscope s front panel Drag on edges of knobs to turn them Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Web Interface 21 AW KEYSIGHT _ Infiniivision MSO X 2024A wus Stage Ondtoncepe zoome 2054 8 mena Zoom Simple Remote Front Panel To operate the oscilloscope using the web interface s Simple Remote Front Panel 1 Access the oscilloscope s web interface see Accessing the Web Interface on page 262 2 When the oscilloscope s web interface is displayed select Browser Web Control then select Simple Remote Front Panel After a few seconds the Remote Front Panel appears 3 Use the Main Menu and the Function Keys to control the oscilloscope To view Quick Help right
224. or push the Entry knob to center the waveform display at the time associated with the selected Lister row and automatically set the horizontal scale setting 7 Press the Undo Zoom softkey to return to the horizontal scale and delay settings before the last Zoom to Selection 8 Press the Options softkey to open the Lister Options Menu In this menu you can Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 103 7 Serial Decode Enable or disable the Track Time option When enabled as you select different Lister rows using the Entry knob while acquisitions are stopped the horizontal delay changes to the Time of the selected row Also changing the horizontal delay will scroll the Lister Press the Scroll Lister softkey and use the Entry knob to scroll though data rows in the Lister display Press the Time Ref softkey and use the Entry knob to select whether the Time column in the Lister display shows times relative to the trigger or relative to the previous packet row Searching Lister Data When serial decode is enabled you can use the Search key to find and place marks on rows in the Lister The Search softkey lets you specify events to find It is similar to specifying protocol triggers Events found are marked in orange in the far left Lister column The total number of events found is displayed above the softkeys 548 0 1 0003 Errors Channels Search for Tx Data
225. ore you only need to select a new channel and press the Apply New Label softkey again to assign the label to the channel Only the original label is saved in the label list This feature makes it easier to assign successive labels to numbered control lines and data bus lines To load a list of labels from a text file you create 116 It may be convenient to create a list of labels using a text editor then load the label list into the oscilloscope This lets you type on a keyboard rather than edit the label list using the oscilloscope s controls You can create a list of up to 75 labels and load it into the oscilloscope Labels are added to the beginning of the list If more than 75 labels are loaded only the first 75 are stored To load labels from a text file into the oscilloscope Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Labels 9 1 Use a text editor to create each label Each label can be up to ten characters in length Separate each label with a line feed 2 Name the file labellist txt and save it on a USB mass storage device such as a thumb drive 3 Load the list into the oscilloscope using the File Explorer press Utility gt File Explorer Label List Management When you press the Library softkey you will see a list of the last 75 labels used The list does not save duplicate labels Labels can end in any number of trailing digits As long as the base string is the same as an existing label
226. orm hardware self test 254 To perform front panel self test 254 To display oscilloscope information 254 To display the user calibration status 255 To clean the oscilloscope 255 To check warranty and extended services status 255 To contact Keysight 255 To return the instrument 255 Configuring the Quick Action Key 256 Adding an Annotation 257 Accessing the Web Interface 262 Browser Web Control 263 Real Scope Remote Front Panel 264 Simple Remote Front Panel 265 Browser Based Remote Front Panel 266 Remote Programming via the Web Interface 267 Remote Programming with Keysight IO Libraries 268 Save Recall 269 Saving Files via the Web Interface 269 Recalling Files via the Web Interface 270 GetImage 271 Identification Function 272 Instrument Utilities 272 Setting a Password 274 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference Specifications and Characteristics 277 Measurement Category 277 Oscilloscope Measurement Category 278 Measurement Category Definitions 278 Transient Withstand Capability 278 A Maximum input voltage at analog inputs 278 A Maximum input voltage at digital channels 279 Environmental Conditions 279 Probes and Accessories 279 Passive Probes 280 Differential Probes 281 Current Probes 281 Accessories Available 282 Loading Licenses and Displaying License Information 282 Licensed Options Available
227. oscilloscope is running the trigger mode tells the oscilloscope what to do when triggers are not occurring In the Auto trigger mode the default setting if the specified trigger conditions are not found triggers are forced and acquisitions are made so that signal activity is displayed on the oscilloscope In the Normal trigger mode triggers and acquisitions only occur when the specified trigger conditions are found To select the trigger mode 1 Press the Mode Coupling key 2 Inthe Trigger Mode and Coupling Menu press the Mode softkey then select either Auto or Normal See the following When to Use Auto Trigger Mode on page 143 and When to Use Normal Trigger Mode on page 143 descriptions You can also configure the Quick Action key to toggle between the Auto and ormal trigger modes See Configuring the Quick Action Key on page 256 After the oscilloscope starts running after pressing Run or Single or changing the trigger condition the oscilloscope first fills the pre trigger buffer Then after the pre trigger buffer is filled the oscilloscope starts searching for a trigger and sampled data continues to flow data through the pre trigger buffer in a first in first out FIFO manner When a trigger is found the pre trigger buffer contains the events that occurred just before the trigger Then the oscilloscope fills the post trigger buffer and displays the acquisition memory If the acquisition was
228. oscilloscope supports methods for automated LAN configuration or manual LAN configuration see To establish a LAN connection on page 243 It is also possible to set up a point to point LAN connection between a PC and the oscilloscope see Stand alone Point to Point Connection to a PC on page 244 Once the oscilloscope is set up on the network you can use the oscilloscope s web page to view or change its network configuration and access additional settings like the network password See Chapter 21 Web Interface starting on page 261 When you connect the oscilloscope to a LAN it is a good practice to limit access to the oscilloscope by setting a password By default the oscilloscope is not password protected See Setting a Password on page 274 to set a password 242 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Utility Settings 20 Any time you modify the oscilloscope s hostname it breaks the connection between the oscilloscope and the LAN You need to re establish communication to the oscilloscope using the new hostname To establish a LAN connection Automatic 1 Press Utility gt 1 0 Configuration 2 Press the LAN Settings softkey 3 Press the Config softkey then turn the Entry knob to select Automatic and press the softkey again to enable it f your network supports DHCP or AutolP enabling Automatic lets the oscilloscope use those services to get its LAN configuration settings 4 If y
229. oscopes User s Guide 49 2 Horizontal Controls To display the zoomed time base 50 Normal lt window Signal anomaly expanded in Zoom window Zoom L window Zoom formerly called Delayed sweep mode is a horizontally expanded version of the normal display When Zoom is selected the display divides in half The top half of the display shows the normal time div window and the bottom half displays a faster Zoom time div window The Zoom window is a magnified portion of the normal time div window You can use Zoom to locate and horizontally expand part of the normal window for a more detailed higher resolution analysis of signals To turn on or off Zoom 1 Press the zoom key or press the Horiz key and then the Zoom softkey These markers show the Time div Time div Delay time beginning and end of the for zoomed for normal momentarily displays Zoom window window window when the Horizontal position knob is turned 2 21V KEYSIGHT TECHNOLOGIES Acquisition h Channels Time Ref Normal Center Select Zoom Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Horizontal Controls 2 The area of the normal display that is expanded is outlined with a box and the rest of the normal display is ghosted The box shows the portion of the normal sweep that is expanded in the lower half To change the time div for the Zoom window turn the horizontal scale sweep speed knob As you t
230. our network provides Dynamic DNS you can enable the Dynamic DNS option to let the oscilloscope register its hostname and use the DNS server for name resolution 5 You can enable the Multicast DNS option to let the oscilloscope use Multicast DNS for name resolution on small networks without a conventional DNS server 6 Connect the oscilloscope to the local area network LAN by inserting the LAN cable into the LAN port on the rear panel of the oscilloscope In a few moments the oscilloscope will connect to the network automatically If the oscilloscope does not automatically connect to the network press Utility gt 1 0 gt LAN Reset In a few moments the oscilloscope will connect to the network Manual 1 Get the oscilloscope s network parameters host name IP address subnet Configuration mask gateway IP DNS IP etc from your network administrator 2 Press Utility gt 1 0 3 Press the LAN Settings softkey 4 Press the Config softkey then turn the Entry knob to select Automatic and press the softkey again to disable it If Automatic is not enabled the oscilloscope s LAN configuration must be set up manually using the Addresses and Host name softkeys Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 243 20 Utility Settings 244 5 Configure the oscilloscope s LAN interface a Press the Addresses softkey b Use the Modify softkey and the other softkeys and the Entry knob to enter the IP
231. p chart recorder It allows the waveform to roll across the display XY Time Mode The XY time mode converts the oscilloscope from a volts versus time display to a volts versus volts display using two input channels Channel 1 is the X axis input channel 2 is the Y axis input You can use various transducers so the display could show strain versus displacement flow versus pressure volts versus Current or voltage versus frequency Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 47 2 48 Horizontal Controls Example This exercise shows a common use of the XY display mode by measuring the phase difference between two signals of the same frequency with the Lissajous method 1 Connect a sine wave signal to channel 1 and a sine wave signal of the same frequency but out of phase to channel 2 2 Press the AutoScale key press the Horiz key then press Time Mode and select XY 3 Center the signal on the display with the channel 1 and 2 position knobs Use the channel 1 and 2 volts div knobs and the channel 1 and 2 Fine softkeys to expand the signal for convenient viewing The phase difference angle 8 can be calculated using the following formula assuming the amplitude is the same on both channels sind Sor Signal must 4a be centered in Y A Measuring Signals 90 degrees Signals phase difference out of phase in phase Fig
232. panel light to blink View installed options view firmware versions and install firmware upgrade files and view calibration status via the Instrument Utilities page View and modify the oscilloscope s network configuration KEYSIGHT TECHNOLOGIES 261 21 Web Interface The web interface for InfiniiVision X Series oscilloscopes also provides help for each of its pages Microsoft Internet Explorer is the recommended Web browser for communication and control of the oscilloscope Other Web browsers may work but are not guaranteed to work with the oscilloscope The Web browser must be Java enabled with Sun Microsystems Java Plug in Before you can use the web interface you must place the oscilloscope on the network and set up its LAN connection Accessing the Web Interface To access the oscilloscope s web interface 1 Connect the oscilloscope to your LAN see To establish a LAN connection on page 243 or establish a point to point connection see Stand alone Point to Point Connection to a PC on page 244 It is possible to use a point to point connection but using a normal LAN connection is the preferred method 2 Type the oscilloscope s hostname or IP address in the web browser The oscilloscope s web interface Welcome Page is displayed 262 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Web Interface 21 Support Products Keysight Site KEYSIGHT Oscilloscope Another web enabl
233. printers supported 235 USB storage device 36 USB CD device 247 USB eject device 36 USB storage device numbering 247 usb2 247 user cal 251 user calibration 251 user interface language 42 User defined threshold 90 utilities 241 Utility key 32 V V RMS FFT vertical units 72 values choosing 32 variable persistence 109 ventilation requirements 25 vernier channel 60 Vertical controls 35 vertical expansion 59 vertical position 59 vertical position knobs 35 vertical scale knobs 35 vertical sensitivity 35 59 Vertical Units FFT 72 VGA video output 39 video trigger 129 viewing tilt the instrument 24 VISA connect string 261 voltage measurements 179 Ww warranted specifications 277 warranty 255 Wave Gen key 32 36 waveform generator 211 waveform generator defaults restoring 220 waveform generator expected output load 214 waveform generator logic presets 215 waveform generator sync pulse 214 Index waveform generator sync pulse TRIG OUT signal 251 waveform generator waveform type 211 Waveform keys 35 waveform type waveform generator 211 waveform cursor tracking 166 waveform intensity 107 waveform printing 235 waveform reference point 247 waveform saving exporting 223 WAVEGEN license 283 web interface 261 web interface accessing 262 white noise adding to waveform generator output 215 Width measurement 188 Width measu
234. quisition with multiple Multiple Analog analog channels Channels 288 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Reference 22 pla eedat Number of Waveforms N 12 bytes Waveform Header 1 Number of Waveform Buffers 1 140 bytes Waveform Date Buffer Type 1 floating point Bytes per Point 4 Header 1 12 bytes Waveform Data Header 2 12 bytes Waveform Data Header N 12 bytes Voltage Data N buffer size Voltage Data 1 buffer size Waveform Header 2 Number of Waveform Buffers 1 140 bytes Buffer Type 1 floating point Bytes per Point 4 Voltage Data 2 buffer size Waveform Header N Number of Waveform Buffers 1 140 bytes Buffer Type 1 floating point Bytes per Point 4 Single Acquisition The following picture shows a binary file of a single acquisition with all pods for the All Pods Logic logic channels saved Channels Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 289 22 Reference pla eedat Number of Waveforms 2 12 bytes Waveform Header 1 Number of Waveform Buffers 1 140 bytes Waveform Data Buffer Type 6 unsigned char Bytes per Point 1 Header 1 12 bytes Waveform Data Header 2 12 bytes Pod 2 Timing Data buffer size Pod 1 Timing Data buffer size Waveform Header 2 Number of Waveform Buffers 1 140 bytes Buffer Type 6 unsigned char Bytes per Point 1 Segmented The following picture
235. r 18 Save Recall Setups Screens Data starting on page 223 To print connect a USB compliant printer For more information about printing see Chapter 19 Print Screens starting on page 235 You can also use the USB port to update the oscilloscope s system software when updates are available You do not need to take special precautions before removing the USB mass storage device from the oscilloscope you do not need to eject it Simply unplug the USB mass storage device from the oscilloscope when the file operation is complete caution Z Do not connect a host computer to the oscilloscope s USB host port Use the device port A host computer sees the oscilloscope as a device so connect the host computer to the oscilloscope s device port on the rear panel See I O Interface Settings on page 241 There is a second USB host port on the back panel 20 Digital channel inputs Connect the digital probe cable to this connector MSO models only See Chapter 6 Digital Channels starting on page 83 21 Waveform generator output Outputs sine square ramp pulse DC or noise on the Gen Out BNC Press the Wave Gen key to set up the waveform generator See Chapter 17 Waveform Generator starting on page 211 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Getting Started 1 Front Panel Overlays for Different Languages Front panel overlays which ha
236. r conditions occur often enough that forced triggers are unnecessary When to Use The Normal trigger mode is appropriate when Normal Trigger Mod You only want to acquire specific events specified by the trigger settings ode Triggering on an infrequent signal from a serial bus for example 12C SPI CAN LIN etc or another signal that arrives in bursts The Normal trigger mode lets you stabilize the display by preventing the oscilloscope from auto triggering Making single shot acquisitions with the Single key Often with single shot acquisitions you must initiate some action in the device under test and you don t want the oscilloscope to auto trigger before that happens Before initiating the action in the circuit wait for the trigger condition indicator Trig d to flash this tells you the pre trigger buffer is filled See Also Forcing a Trigger on page 121 To set the trigger holdoff on page 145 To position the time reference left center right on page 52 To select the trigger coupling 1 Press the Mode Coupling key Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 143 11 Trigger Mode Coupling 2 Inthe Trigger Mode and Coupling Menu press the Coupling softkey then turn the Entry knob to select DC coupling allows DC and AC signals into the trigger path AC coupling places a 10 Hz high pass filter in the trigger path removing any DC offset voltage from the trigger wa
237. r the Digital key Serial triggers can be used when digital channels are on To connect the digital probes to the device under test 1 If necessary turn off the power supply to the device under test KEYSIGHT TECHNOLOGIES 83 6 Digital Channels Turning off power to the device under test would only prevent damage that might occur if you accidentally short two lines together while connecting probes You can leave the oscilloscope powered on because no voltage appears at the probes ov 2 Connect the digital probe cable to the DIGITAL Dn DO connector on the front panel of the mixed signal oscilloscope The digital probe cable is keyed so you can connect it only one way You do not need to power off the oscilloscope CAUTION A Probe cable for digital channels Use only the Keysight logic probe and accessory kit supplied with the mixed signal oscilloscope see Accessories Available on page 282 3 Connect the ground lead on each set of channels each pod using a probe grabber The ground lead improves signal fidelity to the oscilloscope ensuring accurate measurements 84 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Digital Channels 6 Channel Pod Ground Circuit Ground 4 Connect a grabber to one of the probe leads Other probe leads are omitted from the figure for clarity Grabber 5 Connect the grabber to a node in the circuit you w
238. ramp waveform is rising 3 Press the AM Freq softkey and turn the Entry knob to specify the frequency of the modulating signal 4 Press the AM Depth softkey and turn the Entry knob to specify the amount of amplitude modulation AM Depth refers to the portion of the amplitude range that will be used by the modulation For example a depth setting of 80 causes the output amplitude to vary from 10 to 90 90 10 80 of the original amplitude as the modulating signal goes from its minimum to maximum amplitude The following screen shows an AM modulation of a 100 kHz sine wave carrier signal Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 217 17 Waveform Generator 4 28V KEYSIGHT TECHNOLOGIE Acquisition Channels or Modulation Menu Type Waveform AM Depth Symmetry AM v Ramp 50 100 To set up Frequency Modulation FM In the Waveform Generator Modulation Menu under Wave Gen gt Settings gt Modulation 1 Press the Type softkey and turn the Entry knob to select Frequency Modulation FM 2 Press the Waveform softkey and turn the Entry knob to select the shape of the modulating signal Sine Square Ramp Sine Card inal Exponential Rise Exponential Fall When the Ramp shape is selected a Symmetry softkey appears so that you can specify the amount of time per cycle that the ramp waveform is rising 3 Press the FM Freq softkey and turn the Entry knob to specify the freq
239. rches see To set up searches on page 53 is similar to setting up triggers Searches are different than triggers in that they use the measurement threshold settings instead of trigger levels Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Horizontal Controls 2 Found search events are marked with white triangles at the top of the graticule and the number of events found is displayed in the menu line just above the sofkey labels To set up searches 1 Press Search 2 Setting up searches is similar to setting up triggers For setting up Serial searches see Chapter 10 Triggers starting on page 119 and Searching Lister Data on page 104 Remember that searches use the measurement threshold settings instead of trigger levels Use the Thresholds softkey in the Search Menu to access the Measurement Threshold Menu See Measurement Thresholds on page 191 Navigating the Time Base You can use the Navigate key and controls to navigate through Captured data see To navigate time on page 53 Search events see To navigate search events on page 54 Segments when segmented memory acquisitions are turned on see To navigate segments on page 54 To navigate time When acquisitions are stopped you can use the navigation controls to play through the captured data 1 Press Navigate 2 Inthe Navigate Menu press Navigate then select Time 3 Press the SIONS navigation keys to play
240. recessive high Overload Frame The oscilloscope will trigger on CAN overload frames 4 Ifyou select a condition that lets you trigger on ID or data values use the Bits softkey and the CAN Bits Menu to specify those values For details about using the CAN Bits Menu softkeys press and hold the softkey in question to display the built in help You can use the Zoom mode for easier navigation of the decoded data If the setup does not produce a stable trigger the CAN signal may be slow enough that the oscilloscope is AutoTriggering Press the Mode Coupling key then press the Mode softkey to set the trigger mode from Auto to Normal To display CAN serial decode see CAN Serial Decode on page 298 CAN Serial Decode To set up the oscilloscope to capture CAN signals see Setup for CAN Signals on page 295 298 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide CAN LIN Triggering and Serial Decode 23 For CAN triggering set up see CAN Triggering on page 297 To set up CAN serial decode 1 Press Serial to display the Serial Decode Menu FRAMES 1350646044 OVLD 268440068 19 9 Signals AN Lister an 5 2 Ifthe decode line does not appear on the display press the Serial key to turn it on 3 If the oscilloscope is stopped press the Run Stop key to acquire and decode data If the setup does not produce a stable trigger the CAN signal may be slow enough that the oscilloscope is AutoT
241. rement 188 Window FFT 71 X XY mode 47 Z Z axis blanking 49 zoom and pan 44 zoom display measurement window with 193 Zoom key 33 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 345 Index 346 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide
242. rement category Measurement Category Definitions Measurement category is for measurements performed on circuits not directly connected to MAINS Examples are measurements on circuits not derived from MAINS and specially protected internal MAINS derived circuits In the latter case transient stresses are variable for that reason the transient withstand capability of the equipment is made known to the user Measurement category Il is for measurements performed on circuits directly connected to the low voltage installation Examples are measurements on household appliances portable tools and similar equipment easurement category Ill is for measurements performed in the building installation Examples are measurements on distribution boards circuit breakers wiring including cables bus bars junction boxes switches socket outlets in the fixed installation and equipment for industrial use and some other equipment for example stationary motors with permanent connection to the fixed installation easurement category IV is for measurements performed at the source of the ow voltage installation Examples are electricity meters and measurements on primary overcurrent protection devices and ripple control units Transient Withstand Capability CAUTION A Maximum input voltage at analog inputs CAT 300 Vrms 400 Vpk transient overvoltage 1 6 kVpk With 10073C 10 1 probe CAT 500 Vpk With N2862A or N2863A 10 1 probe 300 Vrms
243. rence waveform information on page 82 To scale and position reference waveforms 1 Make sure the multiplexed scale and position knobs to the right of the Ref key are selected for the reference waveform lf the arrow to the left of the Ref key is not illuminated press the key 2 Turn the upper multiplexed knob to adjust the reference waveform scale 3 Turn the lower multiplexed knob to adjust the reference waveform position To adjust reference waveform skew Once reference waveforms are displayed you can adjust their skew 1 Display the desired reference waveform see To display a reference waveform on page 80 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 81 5 Reference Waveforms 2 Press the Skew softkey and turn the Entry knob to adjust the reference waveform skew To display reference waveform information Press the Ref key to turn on reference waveforms 2 Inthe Reference Waveform Menu press the Options softkey 3 In the Reference Waveform Options Menu press the Display Info softkey to enable or disable reference waveform information on the oscilloscope display 4 Press the Transparent softkey to enable or disable transparent information backgrounds This setting is also used for other oscilloscope information on the display like mask test statistics etc To save recall reference waveform files to from a USB storage device Analog channel math or reference waveforms can be saved to
244. ress the Mode Coupling key then press the Mode softkey to set the trigger mode from Auto to Normal You can use the horizontal Zoom window for easier navigation of the decoded data See Also Interpreting LIN Decode on page 308 Interpreting LIN Lister Data on page 309 Searching for LIN Data in the Lister on page 310 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 307 23 CAN LIN Triggering and Serial Decode 308 Interpreting LIN Decode 1 0003 Stop 1 12V Channels Lister gt Angled waveforms show an active bus inside a packet frame Mid level blue lines show an idle bus LIN 1 3 only The hexadecimal ID and parity bits if enabled appear in yellow If a parity error is detected the hexadecimal ID and parity bits if enabled appear in red Decoded hexadecimal data values appear in white For LIN 1 3 the checksum appears in blue if correct or red if incorrect The checksum always appears in white for LIN 2 0 Decoded text is truncated at the end of the associated frame when there is insufficient space within frame boundaries Pink vertical bars indicate you need to expand the horizontal scale and run again to see decode Red dots in the decode line indicate that there is data that is not being displayed Scroll or expand the horizontal scale to view the information Unknown bus values undefined or error conditions are drawn in red If there is an error in the synch fiel
245. riggering Press the Mode Coupling key then press the Mode softkey to set the trigger mode from Auto to Normal You can use the horizontal Zoom window for easier navigation of the decoded data See Also Interpreting CAN Decode on page 300 CAN Totalizer on page 301 Interpreting CAN Lister Data on page 302 Searching for CAN Data in the Lister on page 303 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 299 23 CAN LIN Triggering and Serial Decode Interpreting CAN Decode Frame ID appears in automatically detect rames Data bytes appear in 100 057 Stop CAN 975 KEYSIGHT TECHNOLOGIES Channels UTIL 24 2 Lister gt hex digits in yellow Frames of 11 or 29 bits are ed Remote frame RMT appears in green Data length code DLC appears in blue for data frames and green for remote hex digits in white for data frames Cyclic redundancy check CRC appears in hex digits in blue when valid or in red to indicate that the oscilloscope s hardware decode calculated a CRC that s different from the id ncoming CRC data stream Angled waveforms show an active bus inside a packet frame evel blue lines show an idle bus Decoded text is truncated at the end of the associated frame when there is insufficient space within frame boundaries Pink vertical bars indicate you need to expand the horizontal scale and run again to see decode Red dots in the
246. rizontal axis changes from time to frequency Hertz and the vertical readout changes from volts to dB 70 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Math Waveforms 4 Use the FFT function to find crosstalk problems to find distortion problems in analog waveforms caused by amplifier non linearity or for adjusting analog filters To display a FFT waveform 1 Press the Math key press the Function softkey and select f t press the Operator softkey and select FFT f t FFT Ch1 cale 20dB fset 60 FFT Resolution 763Hz Function Operator Source 1 Span Center f t FFT 500kHz 250kHz Source 1 selects the source for the FFT See To perform a transform function on an arithmetic operation on page 66 for information about using g t as the source Span sets the overall width of the FFT spectrum that you see on the display left to right Divide span by 10 to calculate the number of Hertz per division It is possible to set Span above the maximum available frequency in which case the displayed spectrum will not take up the whole screen Press the Span softkey then turn the Entry knob to set the desired frequency span of the display Center sets the FFT spectrum frequency represented at the center vertical grid line of the display It is possible to set the Center to values below half the span or above the maximum available frequency in which case the displayed spectrum will not take up t
247. rticular pur pose Keysight shall not be liable for errors or for incidental or consequential damages in connection with the fur nishing use or performance of this document or of any information con tained herein Should Keysight and the user have a separate written agreement with warranty terms covering the mate rial in this document that conflict with these terms the warranty terms in the separate agreement shall control Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accor dance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or subcon tract Software is delivered and licensed as Commercial computer software as defined in DFAR 252 227 7014 June 1995 or as a commercial item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract clause Use duplication or disclosure of Software is subject to Keysight Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will receive no greater than Restricted Rights as defined in FAR 52 227 19 c 1 2 June 1987 U S Govern ment users will receive no greater than Lim ited Rights as defined in FAR 52 227 14 June 1987 or DFAR 252 227 70
248. s User s Guide 125 10 Triggers Hex Bus Pattern Trigger You can specify a bus value on which to trigger To do this first define the bus See To display digital channels as a bus on page 91 for details You can trigger on a bus value whether you are displaying the bus or not To trigger on a bus value 1 Press the Pattern key on the front panel 2 Press the Channel softkey and rotate the Entry knob to select Bus1 or Bus2 3 Press the Digit softkey and rotate the Entry knob to select a digit of the selected bus 4 Press the Hex softkey and rotate the Entry knob to select a value for the digit If a digit is made up of less than four bits then the value of the digit will be limited to the value that can be created by the selected bits 5 You can use the Set all Digits softkey to set all digits to a particular value When a hex bus digit contains one or more don t care X bits and one or more bit with a value or O or 1 the sign will be displayed for the digit For information regarding digital bus display when Pattern triggering see Bus values are displayed when using Pattern trigger on page 93 Pulse Width Trigger 126 Pulse Width glitch triggering sets the oscilloscope to trigger on a positive or negative pulse of a specified width If you want to trigger on a specific timeout value use Pattern trigger in the Trigger Menu see Pattern Trigger on page 124 1 Press the Trigger key 2 Inthe Trigger
249. s are dependent on channel scaling probe attenuation and probe units Always set these values first before setting absolute thresholds The minimum and maximum threshold values are limited to on screen values If any of the absolute threshold values are above or below the minimum or maximum waveform values the measurement may not be valid 4 Press the Lower softkey then turn the Entry knob to set the lower measurement threshold value 192 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Measurements 14 Increasing the lower value beyond the set middle value will automatically increase the middle value to be more than the lower value The default lower threshold is 10 or 800 mV If threshold Type is set to the lower threshold value can be set from 5 to 93 5 Press the Middle softkey then turn the Entry knob to set the middle measurement threshold value The middle value is bounded by the values set for lower and upper thresholds The default middle threshold is 50 or 1 20 V If threshold Type is set to the middle threshold value can be set from 6 to 94 6 Press the Upper softkey then turn the Entry knob to set the upper measurement threshold value Decreasing the upper value below the set middle value will automatically decrease the middle value to be less than the upper value The default upper threshold is 90 or 1 50 V Measurement Wi If threshold Type is set to the upper thre
250. s not produce a stable trigger the UART RS232 signals may be slow enough that the oscilloscope is AutoTriggering Press the Mode Coupling key then press the Mode softkey to set the trigger mode from Auto to Normal To display UART RS232 serial decode see UART RS232 Serial Decode on page 333 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide UART RS232 Triggering and Serial Decode 25 UART RS23 Serial Decode To set up the oscilloscope to capture UART RS232 signals see Setup for UART RS232 Signals on page 329 For UART RS232 triggering setup see UART RS232 Triggering on page 331 To set up UART RS232 serial decode 1 Press Serial to display the Serial Decode Menu Serial Decode Menu Mode Signals Bus Config Settings UART AS232 Eza pns _ 2 Press Settings 3 In the UART RS232 Settings Menu press the Base softkey to select the base hex binary or ASCII in which decoded words are displayed Framing off When displaying words in ASCII the 7 bit ASCII format is used Valid ASCII characters are between 0x00 and 0x7F To display in ASCII you must select at least 7 bits in the Bus Configuration If ASCII is selected and the data exceeds 0x7F the data is displayed in hex When Bits is set to 9 in the UART RS232 Bus Configuration Menu the 9th alert bit is displayed directly to the left of the ASCII value which is derived from the lower 8 bits 4 Optional Press the Framing softkey
251. s possible while leaving the complete falling edge of the waveform on the display The Y cursors show the lower and upper threshold points 188 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Measurements 14 Delay Delay measures the time difference from the selected edge on source 1 and the selected edge on source 2 closest to the trigger reference point at the middle threshold points on the waveforms Negative delay values indicate that the selected edge of source 1 occurred after the selected edge of source 2 Source 1 NO A S gt Delay Source 2 yx A AaS Press the Meas key to display the Measurement Menu 2 Press the Source softkey then turn the Entry knob to select the first analog channel source 3 Press the Type softkey then turn the Entry knob to select Delay 4 Press the Settings softkey to select the second analog channel source and slope for the delay measurement The default Delay settings measure from the rising edge of channel 1 to the rising edge of channel 2 5 Press the O Back Up key to return to the Measurement Menu 6 Press the Add Measurement softkey to make the measurement The example below shows a delay measurement between the rising edge of channel 1 and the rising edge of channel 2 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 189 14 Measurements 500 05 43 TECH Acquisition Channels x Measurements Freq 1 4
252. s produced for every factor of 2 averages Random noise is reduced by 1 2 for every factor of 4 averages The number of extra bi ts of vertical resolution is dependent on the setting sweep speed of the oscilloscope The slower the tim averaged together for each display point High Resolution m time per division e div setting the greater the number of samples that are ode can be used on both single shot and repetitive signals and it does not slow waveform update because the computation is done in the MegaZoom custom ASIC High Resolution mode limits the oscilloscope s real time bandwidth because it effectively acts like a low pass filter Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Acquisition Control 12 Sweep speed Bits of resolution lt 1 ps div 8 2 us div 9 5 us div 10 10 us div 11 2 20 us div 12 Acquiring to Segmented Memory To acquire to segmented memory You can purchase the oscilloscope with the segmented memory option factory installed Option SGM or you can install a license to enable it order model number DSOX2SGM Segmented Memory When capturing multiple infrequent trigger events it is advantageous to divide the oscilloscope s memory into segments This lets you capture signal activity without capturing long periods of signal inactivity Each segment is complete with all analog channel digital channel on MSO models and serial decode data W
253. s that will be output to the file Only displayed data points are saved The maximum number of data points depends on these things Whether acquisitions are running When stopped data comes from the raw acquisition record When running data comes from the smaller measurement record Whether the oscilloscope was stopped using Stop or Single Running acquisitions split memory to provide fast waveform update rates Single acquisitions use full memory Whether only one channel of a pair is turned on Channels 1 and 2 are one pair channels 3 and 4 are the other Acquisition memory is divided among the channels in a pair Whether reference waveforms are on Displayed reference waveforms consume acquisition memory Whether digital channels are on Displayed digital channels consume acquisition memory Whether segmented memory is on Acquisition memory is divided by the number of segments The horizontal time div sweep speed setting At faster settings fewer data points appear on the display Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 227 18 Save Recall Setups Screens Data When saving to a CSV format file the maximum number of data points is 50 000 When necessary the Length control performs a 1 of n decimation of the data For example if the Length is set to 1000 and you are displaying a record that is 5000 data points in length four of each five data points will be decimated crea
254. sample rate is determined by the time of the acquisition which is set according to the oscilloscope s horizontal time div scale Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Acquisition Control 12 sample rate number of samples time of acquisition For example when storing 50 us of data in 50 000 points of memory the actual sample rate is 1 GSa s Likewise when storing 50 ms of data in 50 000 points of memory the actual sample rate is 1 MSa s The actual sample rate is displayed in the right side information area The oscilloscope achieves the actual sample rate by throwing away decimating unneeded samples Selecting the Acquisition Mode When selecting the oscilloscope acquisition mode keep in mind that samples are normally decimated at slower time div settings At slower time div settings the effective sample rate drops and the effective sample period increases because the acquisition time increases and the oscilloscope s digitizer is sampling faster than is required to fill memory For example suppose an oscilloscope s digitizer has a sample period of 1 ns maximum sample rate of 1 GSa s anda 1 M memory depth At that rate memory is filled in 1 ms If the acquisition time is 100 ms 10 ms div only 1 of every 100 samples is needed to fill memory To select the acquisition mode E 1 Press the Acquire key on the front panel 2 Inthe Acquire Menu press the Acq Mode soft
255. scilloscopes User s Guide Triggers 10 Pulse width When the greater than gt qualifier is selected the Entry knob sets the trigger gt qualifier oscilloscope to trigger on a pulse width greater than the time value displayed time set softkey on the softkey When the time range gt lt qualifier is selected the Entry knob sets the lower time range value Video Trigger Video triggering can be used to capture the complicated waveforms of most standard analog video signals The trigger circuitry detects the vertical and horizontal interval of the waveform and produces triggers based on the video trigger settings you have selected The oscilloscope s MegaZoom IV technology gives you bright easily viewed displays of any part of the video waveform Analysis of video waveforms is simplified by the oscilloscope s ability to trigger on any selected line of the video signal It is important when using a 10 1 passive probe that the probe is correctly compensated The oscilloscope is sensitive to this and will not trigger if the probe is not properly compensated especially for progressive formats 1 Press the Trigger key 2 Inthe Trigger Menu press the Trigger softkey then turn the Entry knob to select Video Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 129 10 Triggers 130 200 08 Vid Field IGHT EYSIGH TECHNOLOGIES Acquisition Channels Source Settings w 3 Press the Source softke
256. ser s Guide 123 10 Triggers Pattern Trigger The Pattern trigger identifies a trigger condition by looking for a specified pattern This pattern is a logical AND combination of the channels Each channel can have a value of O low 1 high or don t care X A rising or falling edge can be specified for one channel included in the pattern You can also trigger on a hex bus value as described on Hex Bus Pattern Trigger on page 126 1 2 3 124 Press the Trigger key In the Trigger Menu press the Trigger softkey then turn the Entry knob to select Pattern For each analog or digital channel you want to include in the desired pattern press the Channel softkey to select the channel This is the channel source for the 0 1 X or edge condition As you press the Channel softkey or rotate the Entry knob the channel you select is highlighted in the Pattern line directly above the softkeys and in the upper right corner of the display next to Pat Adjust the trigger level for the selected analog channel by turning the Trigger Level knob Press the Digital key and select Thresholds to set the threshold level for digital channels The value of the trigger level or digital threshold is displayed in the upper right corner of the display For each channel you select press the Pattern softkey then turn the Entry knob to set the condition for that channel in the pattern Keysight InfiniiVision 2000 X Series Oscilloscop
257. ser s Guide 187 14 Measurements Width Width is the time from the middle threshold of the rising edge to the middle threshold of the next falling edge The X cursors show the pulse being measured The Y cursor shows the middle threshold point Width Width is the time from the middle threshold of the falling edge to the middle threshold of the next rising edge The X cursors show the pulse being measured The Y cursor shows the middle threshold point Duty Cycle The duty cycle of a repetitive pulse train is the ratio of the positive pulse width to the period expressed as a percentage The X cursors show the time period being measured The Y cursor shows the middle threshold point Width Period 100 Duty cycle Rise Time The rise time of a signal is the time difference between the crossing of the lower threshold and the crossing of the upper threshold for a positive going edge The X cursor shows the edge being measured For maximum measurement accuracy set the horizontal time div as fast as possible while leaving the complete rising edge of the waveform on the display The Y cursors show the lower and upper threshold points Fall Time The fall time of a signal is the time difference between the crossing of the upper threshold and the crossing of the lower threshold for a negative going edge The X cursor shows the edge being measured For maximum measurement accuracy set the horizontal time div as fast a
258. setting is typically slightly less than one repetition of the waveform Set the holdoff to this time to generate a unique trigger point for a repetitive waveform Changing the time base settings does not affect the trigger holdoff time With Keysight s MegaZoom technology you can press Stop then pan and zoom through the data to find where the waveform repeats Measure this time using cursors then set the holdoff External Trigger Input 146 The external trigger input can be used as a source in several of the trigger types The external trigger BNC input is on the rear panel and is labeled EXT TRIG IN Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Trigger Mode Coupling 11 CAUTION A Maximum voltage at oscilloscope external trigger input CAT 300 Vrms 400 Vpk transient overvoltage 1 6 kVpk 1 M ohm input For steady state sinusoidal waveforms derate at 20 dB decade above 57 kHz to a minimum of 5 Vpk With N2863A 10 1 probe CAT 600 V DC peak AC With 10073C or 10074C 10 1 probe CAT 500 Vpk The external trigger input impedance is 1M Ohm This lets you use passive probes for general purpose measurements The higher impedance minimizes the loading effect of the oscilloscope on the device under test To set the EXT TRIG IN units and probe attenuation 1 Press the Mode Coupling key in the Trigger section of the front panel Trigger Mode and Coupling Menu Mode Coupling Noise Rej HF Reject Holdo
259. shold value can be set from 7 to 95 ndow with Zoom Display When the zoomed time base is displayed you can choose whether measurements are m ade in the Main window portion of the display or the Zoom window portion of the display 1 Press the Meas key 2 In the Measurement Menu press the Settings softkey 3 Inthe Measurement Settings Menu press the Meas Window softkey then turn the Entry knob to select from Auto Select The measurement is attempted in the lower Zoom window if it cannot be made there the upper Main window is used Main The measurement window is the upper Main window Zoom The measurement window is the lower Zoom window Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 193 14 Measurements 194 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Mask Testing To create a mask from a golden waveform Automask 195 Mask Test Setup Options 197 Mask Statistics 200 To manually modify a mask file 201 Building a Mask File 204 One way to verify a waveform s compliance to a particular set of parameters is to use mask testing A mask defines a region of the oscilloscope s display in which the waveform must remain in order to comply with chosen parameters Compliance to the mask is verified point by point across the display Mask test operates on displayed analog channels
260. shows a binary file of a segmented memory acquisition on Memory one analog channel Acquisition on One Analog Channel 290 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Reference 22 Fie Meader Number of Waveforms N Number of Segments 12 bytes Number of Waveform Buffers 1 Index 1 Time Tag 0 0 Waveform Header 1 140 bytes Waveform Data Header 1 12 bytes Voltage Data 1 buffer size Waveform Header 2 140 bytes Buffer Type 1 floating point Bytes per Point 4 Number of Waveform Buffers 1 Index 2 Time Tag time between segment 1 and 2 Waveform Date Buffer Type 1 floating point Bytes per Point 4 Header 2 12 bytes Voltage Data 2 buffer size Number of Waveform Buffers 1 Index N Time Tag time between segment 1 and N Waveform Header N 140 bytes Waveform Data Buffer Type 1 floating point Bytes per Point 4 Header N 12 bytes Voltage Data N buffer size CSV and ASCII XY files CSV and ASCII XY file structure on page 292 Minimum and Maximum Values in CSV Files on page 292 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 291 22 Reference 292 CSV and ASCII XY file structure In CSV or ASCII XY format the Length control selects the number of points per segment All segments are contained in the CSV file or in each ASCII XY data file For example If the Length control is set to 1000 points there
261. sired channel key 2 Inthe Channel Menu press the Invert softkey to invert the selected channel When Invert is selected the voltage values of the displayed waveform are inverted Invert affects how a channel is displayed However when using basic triggers the oscilloscope attempts to maintain the same trigger point by changing trigger settings Inverting a channel also changes the result of any math function selected in the Waveform Math Menu or any measurement Setting Analog Channel Probe Options See Also 1 Press the probe s associated channel key 2 Inthe Channel Menu press the Probe softkey to display the Channel Probe Menu This menu lets you select additional probe parameters such as attenuation factor and units of measurement for the connected probe Channel 1 Probe Menu 1 00 1 Probe The Probe Check softkey guides you through the process of compensating passive probes such as the N2862A B N2863A B N2889A N2890A 10073C 10074C or 1165A probes To specify the channel units on page 61 To specify the probe attenuation on page 62 To specify the probe skew on page 62 To specify the channel units 1 Press the probe s associated channel key 2 Inthe Channel Menu press Probe Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 61 3 62 Vertical Controls 3 In the Channel Probe Menu press Units then select Volts for a voltage probe Amps for a current probe
262. softkey and turn the Entry knob to select the desired reference waveform location 3 Press the Source softkey and turn the Entry knob to select the source waveform KEYSIGHT TECHNOLOGIES 79 5 Reference Waveforms 4 Press the Save to R1 R2 softkey to save the waveform to the reference waveform location Reference waveforms are non volatile they remain after power cycling or performing a default setup Tocleara 1 Press the Ref key to turn on reference waveforms reference 2 Inthe Reference Waveform Menu press the Ref softkey and turn the Entry knob waveform location to select the desired reference waveform location 3 Press the Clear R1 R2 softkey to clear the reference waveform location Reference waveforms are also cleared by a Factory Default or Secure Erase see Chapter 18 Save Recall Setups Screens Data starting on page 223 To display a reference waveform 1 Press the Ref key to turn on reference waveforms 2 Inthe Reference Waveform Menu press the Ref softkey and turn the Entry knob to select the desired reference waveform location 3 Then press the Ref softkey again to enable disable the reference waveform display 80 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Reference Waveforms 5 1 7605 500 08 1 14 KEYSIGHT TECHNOLOGIE Acquisition Channels Options gt Source One reference waveform can be displayed at a time See Also To display refe
263. splay oscilloscope information on page 254 To display the user calibration status on page 255 For other information related to oscilloscope maintenance and service see To clean the oscilloscope on page 255 To check warranty and extended services status on page 255 To contact Keysight on page 255 To return the instrument on page 255 To perform user calibration Perform user calibration Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 251 20 Utility Settings 252 Every two years or after 4000 hours of operation If the ambient temperature is gt 10 C from the calibration temperature If you want to maximize the measurement accuracy The amount of use environmental conditions and experience with other instruments help determine if you need shorter User Cal intervals User Cal performs an internal self alignment routine to optimize the signal path in the oscilloscope The routine uses internally generated signals to optimize circuits that affect channel sensitivity offset and trigger parameters Performing User Cal will invalidate your Certificate of Calibration If NIST National nstitute of Standards and Technology traceability is required perform the Performance Verification procedure in the Keysight InfiniiVision 2000 3000 X Series Oscilloscopes Service Guide using traceable sources To perform user calibration 1 Disconnect all inputs from the front and rear panels including th
264. ss the Format softkey and select Mask Press the second softkey and select a destination folder on your USB mass storage device 7 Press the Press to Save softkey This creates an ASCII text file that describes the mask 8 Remove the USB mass storage device and connect it to a PC 9 Open the msk file your created using a text editor such as Wordpad 10 Edit save and close the file The mask file contains the following sections Mask File Identifier Mask Title Mask Violation Regions Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 201 15 Mask Testing Mask File Identifier 202 Mask Title Mask Violation Regions Oscilloscope Setup Information The Mask File Identifier is MASK_FILE_548XxX The Mask Title is a string of ASCII characters Example autoMask CH1 OCT 03 09 40 26 2008 When a mask file contains the keyword autoMask in the title the edge of the mask is passing by definition Otherwise the edge of the mask is defined as a failure 50 008 Trig d 2 00V KEYSIGHT TEC IES Region 1 Region 2 Up to 8 regions can be defined for a mask They can be numbered 1 8 They can appear in any order in the msk file The numbering of the regions must go from top to bottom left to right An Automask file contains two special regions the region glued to the top of the display and the region that is glued to the bottom The top region is indicated by y values of MA
265. st horizontally and can be used to measure time s frequency 1 s phase and ratio The X1 cursor is the short dashed vertical line and the X2 cursor is the long dashed vertical line When used with the FFT math function as a source the X cursors indicate frequency In XY horizontal mode the X cursors display channel 1 values Volts or Amps The X1 and X2 cursor values for the selected waveform source are displayed in the softkey menu area The difference between X1 and X2 AX and 1 AX are displayed in the Cursors box in the right side information area Y Cursors Y cursors are horizontal dashed lines that adjust vertically and can be used to measure Volts or Amps dependent on the channel Probe Units setting or they can measure ratios When math functions are used as a source the measurement units correspond to that math function KEYSIGHT TECHNOLOGIES 165 13 Cursors The Y1 cursor is the short dashed horizontal line and the Y2 cursor is the long dashed horizontal line The Y cursors adjust vertically and typically indicate values relative to the waveform s ground point except math FFT where the values are relative to 0 dB In XY horizontal mode the Y cursors display channel 2 values Volts or Amps When active the Y1 and Y2 cursor values for the selected waveform source are displayed in the softkey menu area The difference between Y1 and Y2 AY is displayed in the Cursors box in the right sid
266. t InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling To select the Auto or Normal trigger mode 142 To select the trigger coupling 143 To enable or disable trigger noise rejection 145 To enable or disable trigger HF Reject 145 To set the trigger holdoff 145 External Trigger Input 146 To access the Trigger Mode and Coupling Menu In the Trigger section of the front panel press the Mode Coupling key id Coupling Menu Coupling Noise Rej HF Reject Holdoff External DC 40 000ns ma Noisy Signals If the signal you are probing is noisy you can set up the oscilloscope to reduce the noise in the trigger path and on the displayed waveform First stabilize the displayed waveform by removing the noise from the trigger path Second reduce the noise on the displayed waveform 1 Connect a signal to the oscilloscope and obtain a stable display 2 Remove the noise from the trigger path by turning on high frequency rejection To enable or disable trigger HF Reject on page 145 low frequency rejection To select the trigger coupling on page 143 or To enable or disable trigger noise rejection on page 145 3 Use Averaging Acquisition Mode on page 158 to reduce noise on the displayed waveform KEYSIGHT TECHNOLOGIES 141 11 Trigger Mode Coupling To select the Auto or Normal trigger mode Triggering and the Pre and Post Trigger Buffers Trigger Indicator 142 When the
267. t address read or write frame condition or a 10 bit write frame condition a Press the Address softkey and turn the Entry knob to select the 7 bit or 10 bit device address You can select from an address range of 0x00 to Ox7F 7 bit or Ox3FF 10 bit hexadecimal When triggering on a read write frame the oscilloscope will trigger after the start address read write acknowledge and data events occur If don t care is selected OxXX or OxXXX for the address the address will be ignored The trigger will always occur on the 17th clock for 7 bit addressing or 26th clock for 10 bit addressing b Press the Data value softkey and turn the Entry knob to select the 8 bit data pattern on which to trigger You can select a data value in the range of 0x00 to OxFF hexadecimal The oscilloscope will trigger after the start address read write acknowledge and data events occur If don t care OxXX is selected for data the data will be ignored The trigger will always occur on the 17th clock for 7 bit addressing or 26th clock for 10 bit addressing c lf you have selected a three byte trigger press the Data2 value softkey and turn the Entry knob to select the 8 bit data pattern on which to trigger To display I2C serial decode see 12C Serial Decode on page 316 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 315 24 2C SPI Triggering and Serial Decode I2C Serial Decode See Also 316 To set up the oscillos
268. t erasing the default library Pressing Default Setup sets all channel labels back to the default labels but does not erase the list of user defined labels in the library 118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers Adjusting the Trigger Level 120 Forcing a Trigger 121 Edge Trigger 121 Pattern Trigger 124 Pulse Width Trigger 126 Video Trigger 129 Serial Trigger 138 A trigger setup tells the oscilloscope when to acquire and display data For example you can set up to trigger on the rising edge of the analog channel 1 input signal You can adjust the vertical level used for analog channel edge detection by turning the Trigger Level knob In addition to the edge trigger type you can also set up triggers on pulse widths patterns and video signals You can use any input channel or the External Trigger Input on page 146 BNC as the source for most trigger types Changes to the trigger setup are applied immediately If the oscilloscope is stopped when you change a trigger setup the oscilloscope uses the new specification when you press Run Stop or Single If the oscilloscope is running when you change a trigger setup it uses the new trigger definition when it starts the next acquisition You can use the Force Trigger key to acquire and display data when triggers are not occurring You can use the
269. ta length code Data data bytes CRC cyclic redundancy check Errors highlighted in red Errors can be Acknowledge Ack A Form Fo or Frame Fr Different kinds of errors can be combined like Fo Fr in the above example Aliased data is highlighted in pink When this happens decrease the horizontal time div setting and run again 302 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide CAN LIN Triggering and Serial Decode 23 Searching for CAN Data in the Lister The oscilloscope s search capability lets you search for and mark certain types of CAN data in the Lister You can use the Navigate key and controls to navigate through the marked rows 1 With CAN selected as the serial decode mode press Search 2 Inthe Search Menu press the Search softkey then turn the Entry knob to select the serial slot Serial 1 or Serial 2 on which the CAN signal is being decoded 3 Press Search then select from these options Remote Frame ID RTR Finds remote frames with the specified ID Press the Bits softkey to enter the ID Data Frame ID RTR Finds data frames matching the specified ID Press the Bits softkey to enter the ID Remote or Data Frame ID Finds remote or data frames matching the specified ID Press the Bits softkey to select the ID Data Frame ID and Data Finds data frames matching the specified ID and data Press the Bits softkey to set the ID length ID value n
270. tails The ability to examine waveform detail after the waveform has been acquired is a benefit generally associated with digital oscilloscopes Often this is simply the ability to freeze the display for the purpose of measuring with cursors or printing the screen Some digital oscilloscopes go one step further by including the ability to further examine the signal details after acquiring them by panning through the waveform and changing the horizontal scale There is no limit imposed on the scaling ratio between the time div used to acquire the data and the time div used to view the data There is however a useful limit This useful limit is somewhat a function of the signal you are analyzing Zooming into stopped acquisitions The screen will still contain a relatively good display if you zoom in horizontally by a factor of 1000 and zoom in vertically by a factor of 10 to display the information from where it was acquired Remember that you can only make automatic measurements on displayed data To change the horizontal time mode Normal XY or Roll 1 Press Horiz 2 Inthe Horizontal Menu press Time Mode then select 46 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Horizontal Controls 2 Normal the normal viewing mode for the oscilloscope In the Normal time mode signal events occurring before the trigger are plotted to the left of the trigger point W and signal events after the trigger plotted to
271. tart condition Read En Write SDA UA eee Sue Oe aa ar set _ 1 7 _ e _ 9 _ 1 8 _ 9 1 7 t SG Start Address R W Ack Data Ack Data2 Ack Stop Condition Trigger point Condition 26th clock edge 10 bit Write The oscilloscope triggers on a 10 bit write frame on the 26th clock edge if all bits in the pattern match The frame is in the format Frame Start Address byte 1 Write Address byte 2 Ack Data For triggering purposes a restart is treated as a start condition Write MTA EN sa TA AAAA ATA AAA U Start or Address R Aoki Address Ack2 Data Ack Stop Restart 1st byte 2nd byte Trigger point Condition Condition 26th clock edge Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide I2C SPI Triggering and Serial Decode 24 5 Ifyou have set the oscilloscope to trigger on an EEPROM Data Read condition Press the Data is softkey to set the oscilloscope to trigger when data is equal to not equal to lt less than or gt greater than the data value set in the Data softkey The oscilloscope will trigger on the clock edge for the Ack bit after the trigger event is found This data byte does not need to occur directly after the control byte The oscilloscope will trigger on any data byte that meets the criteria defined by the Data is and Data softkeys during a current address read or a random read or a sequential read cycle 6 Ifyou have set the oscilloscope to trigger on a 7 bi
272. that you specify For use when the DUT data words are from 5 to 8 bits in length no 9th alert bit Rx 1 Data For use when the DUT data words are 9 bits in length including the alert bit the 9th bit Finds only when the 9th alert bit is 1 The specified data byte applies to the least significant 8 bits excludes the 9th alert bit Rx 0 Data For use when the DUT data words are 9 bits in length including the alert bit the 9th bit Finds only when the 9th alert bit is 0 The specified data byte applies to the least significant 8 bits excludes the 9th alert bit Rx X Data For use when the DUT data words are 9 bits in length including the alert bit the 9th bit Finds a data byte that you specify regardless of the value of the 9th alert bit The specified data byte applies to the least significant 8 bits excludes the 9th alert bit Similar choices are available for Tx Rx or Tx Parity Error Finds a parity error based on the parity you have set in the Bus Configuration Menu Rx or Tx Any Error Finds any error For more information on searching data see Searching Lister Data on page 104 For more information on using the Navigate key and controls see Navigating the Time Base on page 53 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 337 25 UART RS232 Triggering and Serial Decode 338 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Index
273. the Gen Out BNC is fixed at 50 ohms However the output load selection lets the waveform generator display the correct amplitude and offset levels for the expected output load If the actual load impedance is different than the selected value the displayed amplitude and offset levels will be incorrect To use waveform generator logic presets With logic level presets you can easily set the output voltage to TTL CMOS 5 0V CMOS 3 3V CMOS 2 5V or ECL compatible Low and High levels 1 If the Waveform Generator Menu is not currently displayed on the oscilloscope s softkeys press the Wave Gen key 2 In the Waveform Generator Menu press the Settings softkey 3 In the Waveform Generator Settings Menu press the Logic Presets softkey 4 Inthe Waveform Generator Logic Level Presets Menu press one of the softkeys to set the generated signal s Low and High voltages to logic compatible levels Softkey logic levels Low level High level 50 ohm High level high Z expected output load expected output load TTL OV 2 5 V TTL compatible 5 V CMOS 5 0V OV Not Available 5V CMOS 3 3V OV 2 5 V CMOS 3 3 V compatible CMOS 2 5V OV 2 5 V 2 5 V ECL 1 7 V 0 8 V ECL compatible 0 9 V To add noise to the waveform generator output 1 If the Waveform Generator Menu is not currently displayed on the oscilloscope s softkeys press the Wave Gen key Keysight InfiniiVision 2000 X Series Osci
274. the Serial Decode Menu Serial Decode Menu Mode Signals Word Size Bit Order Lister SPI es MSB p S 2 Press the Word Size softkey then turn the Entry knob to select the number of bits in a word 3 Press the Bit Order softkey then turn the Entry knob to select the bit order most significant bit first MSB or least significant bit first LSB used when displaying data in the serial decode waveform and in the Lister 4 Ifthe decode line does not appear on the display press the Serial key to turn it on 5 Ifthe oscilloscope is stopped press the Run Stop key to acquire and decode data If the setup does not produce a stable trigger the SPI signal may be slow enough that the oscilloscope is AutoTriggering Press the Mode Coupling key then press the Mode softkey to set the trigger mode from Auto to Normal You can use the horizontal Zoom window for easier navigation of the acquired data See Also Interpreting SPI Decode on page 326 Interpreting SPI Lister Data on page 327 Searching for SPI Data in the Lister on page 327 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 325 24 326 12C SPI Triggering and Serial Decode Interpreting SP Decode 5 00 5 00 5 00 5 00 1 0003 Channels FE FE FF OFF FF FF FE FF FF 7F X FRX FF O2 FF FF FF 0 53 4F Serial Decode Menu 05 FFX02 20 21 Signals Word Size Bit Order Lister al 8 MSB Angled waveforms show an active bus inside a
275. the line or count numbers per field for each video standard Video standard Field 1 Field 2 Alt Field NTSC 1 to 263 1 to 262 1 to 262 PAL 1 to 313 314 to 625 1 to 312 PAL M 1 to 263 264 to 525 1 to 262 SECAM 1 to 313 314 to 625 1 to 312 The following are exercises to familiarize you with video triggering These exercises use the NTSC video standard To trigger on a specific line of video on page 132 To trigger on all sync pulses on page 134 To trigger on a specific field of the video signal on page 134 To trigger on all fields of the video signal on page 135 To trigger on odd or even fields on page 136 Video triggering requires greater than 1 2 division of sync amplitude with any analog channel as the trigger source Turning the trigger Level knob in Video trigger does not change the trigger level because the trigger level is automatically set to the sync pulse tips One example of triggering on a specific line of video is looking at the vertical interval test signals VITS which are typically in line 18 Another example is closed captioning which is typically in line 21 1 Press the Trigger key Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Triggers 10 2 In the Trigger Menu press the Trigger softkey then turn the Entry knob to select Video 3 Press the Settings softkey then press the Standard softkey to select the appropriate TV standard NTSC
276. the right of the trigger point XY XY mode changes the display from a volts versus time display to a volts versus volts display The time base is turned off Channel 1 amplitude is plotted on the X axis and Channel 2 amplitude is plotted on the Y axis You can use XY mode to compare frequency and phase relationships between two signals XY mode can also be used with transducers to display strain versus displacement flow versus pressure volts versus current or voltage versus frequency Use the cursors to make measurements on XY mode waveforms For more information about using XY mode for measurements refer to XY Time Mode on page 47 Roll causes the waveform to move slowly across the screen from right to left It only operates on time base settings of 50 ms div and slower If the current time base setting is faster than the 50 ms div limit it will be set to 50 ms div when Roll mode is entered In Roll mode there is no trigger The fixed reference point on the screen is the right edge of the screen and refers to the current moment in time Events that have occurred are scrolled to the left of the reference point Since there is no trigger no pre trigger information is available If you would like to pause the display in Roll mode press the Single key To clear the display and restart an acquisition in Roll mode press the Single key again Use Roll mode on low frequency waveforms to yield a display much like a stri
277. this softkey to delete the character You can use a connected USB keyboard instead of using the Spell and other character editing softkeys Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 237 19 Print Screens 6 Press the Apply softkey to make the printer connection A message appears to tell you whether the connection was successful To specify the print options In the Print Configuration Menu press the Options softkey to change the following options Setup Information Select this to print oscilloscope setup information on your printout including vertical horizontal trigger acquisition math and display settings Invert Graticule Colors Select this to reduce the amount of black ink it takes to print oscilloscope images by changing the black background to white Invert Graticule Colors is the default mode Graticule Not Inverted Graticule Inverted Form Feed Se waveform is pri Feed off if you wan the waveform T selected Also setting Landscape Se portrait mode ect this to send a form feed command to the printer after the nted and before the setup information is printed Switch Form t setup information printed on the same sheet of paper with his option only has an effect when the Setup Information option is if the amount of setup information will not fit on the same page with the waveform it will be printed on a new page regardless of the Form Feed
278. ting an output file 1000 data points in length When saving waveform data the save times depend on the chosen format Data File Format Save Times BIN fastest ASCII XY medium CSV slowest See Also Binary Data bin Format on page 284 CSV and ASCII XY files on page 291 Minimum and Maximum Values in CSV Files on page 292 To save Lister data files Lister data files can be saved to an external USB storage device 1 Press Save Recall gt Save gt Format then turn the Entry knob to select Lister data file 2 Press the softkey in the second position and use the Entry knob to navigate to the save location See To navigate storage locations on page 230 3 Press the Settings softkey In the File Settings Menu you have these softkeys and options Setup Info when enabled setup information vertical horizontal trigger acquisition math and display settings is also saved in a separate file with a TXT extension 4 Finally press the Press to Save softkey A message indicating whether the save was successful is displayed 228 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Save Recall Setups Screens Data 18 To save reference waveform files to a USB storage device Press the Save Recall key 2 Inthe Save Recall Menu press the Save softkey 3 In the Save Menu press the Format softkey and turn the Entry knob to select Reference Waveform data h5 4
279. torage locations on a connected USB storage device The softkey in the second position can have these labels Press to go when you can push the Entry knob to navigate to a new folder or storage location Location when you have navigated to the current folder location and are not saving files Save to when you can save to the selected location Load from when you can recall from the selected file When saving files The proposed file name is shown in the Save to file line above the softkeys To overwrite an existing file browse to that file and select it To create a new file name see To enter file names on page 230 To enter file names To create new file names when saving files to a USB storage device 1 Inthe Save Menu press the File Name softkey You must have a USB storage device connected to the oscilloscope for this softkey to be active 2 Inthe File Name Menu use the Spell Enter and Delete Character softkeys to enter the file name Spell press this softkey and turn the Entry knob to select the character at the current position Enter press this softkey to enter characters and move the cursor to the next character position Pushing the Entry knob is the same as pressing the Enter softkey Delete Character press this softkey to delete the character at the current position 230 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Save Recall Setups Screens Data
280. trigger on all sync pulses 134 To trigger on a specific field of the video signal 134 To trigger on all fields of the video signal 135 To trigger on odd or even fields 136 Serial Trigger 138 11 Trigger Mode Coupling To select the Auto or Normal trigger mode 142 To select the trigger coupling 143 To enable or disable trigger noise rejection 145 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 To enable or disable trigger HF Reject 145 To set the trigger holdoff 145 External Trigger Input 146 A Maximum voltage at oscilloscope external trigger input 147 12 Acquisition Control Running Stopping and Making Single Acquisitions Run Control 149 Overview of Sampling 150 Sampling Theory 151 Aliasing 151 Oscilloscope Bandwidth and Sample Rate 151 Oscilloscope Rise Time 153 Oscilloscope Bandwidth Required 154 Memory Depth and Sample Rate 154 Selecting the Acquisition Mode 155 Normal Acquisition Mode 156 Peak Detect Acquisition Mode 156 Averaging Acquisition Mode 158 High Resolution Acquisition Mode 160 Acquiring to Segmented Memory 161 Navigating Segments 162 Infinite Persistence with Segmented Memory 163 Segmented Memory Re Arm Time 163 Saving Data from Segmented Memory 163 13 Cursors To make cursor measurements 166 Cursor Examples 169 12 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements To make automatic m
281. uble precision 64 bit floating point number If the value is zero then no data has been acquired X Increment A 64 bit double that is the duration between data points on the X axis For time domain waveforms this is the time between points If the value is zero then no data has been acquired X Origin A 64 bit double that is the X axis value of the first data point in the data record For time domain waveforms it is the time of the first point This value is treated as a double precision 64 bit floating point number If the value is zero then no data has been acquired X Units A 32 bit integer that identifies the unit of measure for X values in the acquired data 0 Unknown 1 Volts 2 Seconds 3 Constant 4 Amps 5 dB 6 Hz Y Units A 32 bit integer that identifies the unit of measure for Y values in the acquired data The possible values are listed above under X Units Date A 16 byte character array left blank in InfiniiVision oscilloscopes Time A 16 byte character array left blank in the InfiniiVision oscilloscopes Frame A 24 byte character array that is the model number and serial number of the oscilloscope in the format of MODEL SERIAL Waveform Label A 16 byte character array that contains the label assigned to the waveform Time Tags Segment Index A 64 bit double only used when saving multiple segments requires segmented memor
282. uency Model oO Z 1k Typical 100 Model 10 1 10kHz 100kHz 1MHz 10MHz 100 MHz 1 GHz Frequency Figure 11 Impedance versus Frequency for Both Probe Circuit Models The logic probes are represented by the high frequency circuit model shown above They are designed to provide as much series tip resistance as possible Stray tip capacitance to ground is minimized by the proper mechanical design of the probe tip assembly This provides the maximum input impedance at high frequencies Probe Grounding A probe ground is the low impedance path for current to return to the source from the probe Increased length in this path will at high frequencies create large common mode voltages at the probe input The voltage generated behaves as if this path were an inductor according to the equation Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Digital Channels 6 di vai Increasing the ground inductance L increasing the current di or decreasing the transition time dt will all result in increasing the voltage V When this voltage exceeds the threshold voltage defined in the oscilloscope a false data measurement will occur Sharing one probe ground with many probes forces all the current that flows into each probe to return through the same common ground inductance of the probe whose ground return is used The result is increased current di in the above equation and depending on the transitio
283. uency of the modulating signal 218 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Waveform Generator 17 4 Press the FM Dev softkey and turn the Entry knob to specify the frequency deviation from the original carrier signal frequency When the modulating signal is at its maximum amplitude the output frequency is the carrier signal frequency plus the deviation amount and when the modulating signal is at its minimum amplitude the output frequency is the carrier signal frequency minus the deviation amount The frequency deviation cannot be greater than the original carrier signal frequency Also the sum of the original carrier signal frequency and the frequency deviation must be less than or equal to the maximum frequency for the selected waveform generator function plus 100 kHz The following screen shows an FM modulation of a 100 kHz sine wave carrier signal 50 005 Stop 4 28V KEYSIGHT TECHNOLOGIES Channels Aodulation Menu Type Waveform FM Freq Symmetry FM N Ramp 10kHz 100 To set up Frequency Shift Keying Modulation FSK In the Waveform Generator Modulation Menu under Wave Gen gt Settings gt Modulation Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 219 17 Waveform Generator 1 Press the Type softkey and turn the Entry knob to select Frequency Shift Keying Modulation FSK 2 Press the Hop Freq softkey and turn the Entry knob to specify the hop frequency
284. ulation waveform generator output 216 module installed 254 module slot 39 MSO 3 MSO feature upgrade 284 MSO license 283 Multicast DNS 243 Multiply math function 69 N N8900A InfiniiView oscilloscope analysis software 224 navigate files 245 Navigate key 33 navigating the time base 53 network configuration parameters 261 network printer connection 236 network connecting to 243 new label 115 noise rejection 145 noise waveform generator output 213 noise adding to waveform generator output 215 noise high frequency 145 noise low frequency 144 noisy signals 141 non volatile memory secure erase 233 normal acquire mode 156 normal mode 155 156 Normal trigger mode 142 notices 2 Nyquist frequency 76 Nyquist sampling theory 151 0 operators math 68 options print 238 oscilloscope bandwidth 151 oscilloscope bandwidth required 154 oscilloscope rise time 153 oscilloscope sample rate 153 output load expected waveform generator 214 output trigger 250 overlay localized 37 Overshoot measurement 178 181 overvoltage category 279 P palette 226 pan and zoom 44 parts replacement 98 passive probes 280 passive probes compensating 29 password network reset 276 password network setting 274 pattern trigger 124 pattern SPI trigger 324 PC connection 244 peak detect mode 155 156 Peak peak measurement 180 Period measurement
285. umber of data bytes and data value Error Frame Finds CAN active error frames All Errors Finds any form error or active error Overload Frame Finds CAN overload frames For more information on searching data see Searching Lister Data on page 104 For more information on using the Navigate key and controls see Navigating the Time Base on page 53 Setup for LIN Signals LIN Local Interconnect Network signal setup consists of connecting the oscilloscope to a serial LIN signal specifying the signal source threshold voltage level baud rate sample point and other LIN signal parameters To set up the oscilloscope to capture LIN signals 1 Press Label to turn on labels 2 Press Serial Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 303 23 CAN LIN Triggering and Serial Decode Press the Mode softkey then select LIN trigger type Press the Signals softkey to open the LIN Signals Menu Threshold Baud Rate Sample Point Standard Syne Break 2V T 60 0 LIN 1 3 ai Press the Source softkey to select the channel connected to the LIN signal line The label for the LIN source channel is automatically set Press the Threshold softkey then turn the Entry knob to set the LIN signal threshold voltage level to the middle of the LIN signal The threshold voltage level is used in decoding and it will become the trigger level when the trigger type is set to the selected serial d
286. urce Add Settings Clear Meas Softkeys y Figure 1 Interpreting the oscilloscope display 40 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Getting Started 1 Status line The top line of the display contains vertical horizontal and trigger setup information Display area The display area contains the waveform acquisitions channel identifiers and analog trigger and ground level indicators Each analog channel s information appears in a different color Signal detail is displayed using 256 levels of intensity For more information about viewing signal detail see To adjust waveform intensity on page 107 For more information about display modes see Chapter 8 Display Settings starting on page 107 Information area The information area normally contains acquisition analog channel automatic measurement and cursor results Menu line This line normally contains menu name or other information associated with the selected menu Softkey labels These labels describe softkey functions Typically softkeys let you set up additional parameters for the selected mode or menu Pressing the Back Up key at the top of the menu hierarchy turns off softkey labels and displays additional status information describing channel offset and other configuration parameters Access the Built In Quic k Help To view Quick Help 1 Press and hold the key or softkey for which you would
287. ure 3 XY time mode signals centered on display 4 Press the Cursors key 5 Set the Y2 cursor to the top of the signal and set Y1 to the bottom of the signal Note the AY value at the bottom of the display In this example we are using the Y cursors but you could have used the X cursors instead Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Horizontal Controls 2 6 Move the Y1 and Y2 cursors to the intersection of the signal and the Y axis Again note the AY value KEYSIGHT TECHN Channels Cursors 0 0 1 73 Cursors XT ov TE 1 21250V 2 X2 Figure 4 Phase difference measurements automatic and using cursors 7 Calculate the phase difference using the formula below For example if the first AY value is 1 688 and the second AY value is 1 031 second AY _ 1 031 sind first AY 1 688 0 37 65 degrees of phase shift Z Axis Input in XY Display Mode Blanking When you select the XY display mode the time base is turned off Channel 1 is the X axis input channel 2 is the Y axis input and the rear panel EXT TRIG IN is the Z axis input If you only want to see portions of the Y versus X display use the Z axis input Z axis turns the trace on and off analog oscilloscopes called this Z axis blanking because it turned the beam on and off When Z is low lt 1 4 V Y versus X is displayed when Z is high gt 1 4 V the trace is turned off Keysight InfiniiVision 2000 X Series Oscill
288. ure 30 Cursors track Zoom window Cursors 13 1 00 KEYSIGHT TECH Acquisition Channels Cursors 64 400ns 1 15 5 A T Put the X1 cursor on one side of a pulse and the X2 cursor on the other side of the pulse Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 171 13 Cursors 1 00 KEYSIGHT TECH Acquisition Channels Cursors Mode Source Cursors Manual X2 Figure 31 Measuring pulse width with cursors Press the X1 X2 linked softkey and move the cursors together to check for pulse width variations in a pulse train 172 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Cursors 13 1 00 KEYSIGHT TECHNO Acquisition Channels Cursors AY 1 Mode Source Cursors Manual X1X2 Figure 32 Moving the cursors together to check pulse width variations Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 173 13 Cursors 174 Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements To make automatic measurements 176 Measurements Summary 177 Voltage Measurements 179 Time Measurements 186 Measurement Thresholds 191 Measurement Window with Zoom Display 193 The Meas key lets you make automatic measurements on waveforms Some measurements can only be made on analog input channels The results of the last four selected measurements ar
289. urn the knob the zoomed window time div is highlighted in the status line above the waveform display area The Horizontal scale sweep speed knob controls the size of the box The Horizontal position delay time knob sets the left to right position of the zoom window The delay value which is the time displayed relative to the trigger point is momentarily displayed in the upper right portion of the display when the delay time knob is turned Negative delay values indicate you re looking at a portion of the waveform before the trigger event and positive values indicate you re looking at the waveform after the trigger event To change the time div of the normal window turn off Zoom then turn the horizontal scale sweep speed knob For information about using zoom mode for measurements refer to To isolate a pulse for Top measurement on page 181 and To isolate an event for frequency measurement on page 187 To change the horizontal scale knob s coarse fine adjustment setting 1 Push the horizontal scale knob or press Horiz gt Fine to toggle between fine and coarse adjustment of the horizontal scale When Fine is enabled turning the horizontal scale knob changes the time div displayed in the status line at the top of the display in smaller increments The time div remains fully calibrated when Fine is on When Fine is turned off the Horizontal scale knob changes the time div setting in a 1 2 5 step sequence
290. ussian distribution two sigma 10 from the mean is where 68 3 percent of the measurement results reside Six sigma 30 from is where 99 7 percent of the measurement results reside mean 30 20 10 0 10 20 30 68 3 95 4 99 7 The mean is calculated as follows DE x N where x the mean N the number of measurements taken x the ith measurement result The standard deviation is calculated as follows N 2 XiT x g N where o the standard deviation N the number of measurements taken Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 185 14 Measurements x the ith measurement result x the mean Time Measurements The following figure shows time measurement points Rise Time Fall Time A i lt i k Thresholds I Lower Width Width Period gt i The default lower middle and upper measurement thresholds are 10 50 and 90 between Top and Base values See Measurement Thresholds on page 191 for other percentage threshold and absolute value threshold settings Period on page 186 Frequency on page 187 Width on page 188 Width on page 188 Duty Cycle on page 188 Rise Time on page 188 Fall Time on page 188 Delay on page 189 Phase on page 190 Period Period is the time period of the complete waveform cycle The time is measured between
291. usts for input line voltages in the range 100 to 240 VAC The line cord provided is matched to the country of origin WARNING Always use a grounded power cord Do not defeat the power cord ground 3 Press the power switch The power switch is located on the lower left corner of the front panel The oscilloscope will perform a self test and will be operational in a few seconds Connect Probes to the Oscilloscope CAUTION 1 Connect the oscilloscope probe to an oscilloscope channel BNC connector 2 Connect the probe s retractable hook tip to the point of interest on the circuit or device under test Be sure to connect the probe ground lead to a ground point on the circuit A Maximum input voltage at analog inputs CAT 300 Vrms 400 Vpk transient overvoltage 1 6 kVpk With 10073C 10 1 probe CAT 500 Vpk With N2862A or N2863A 10 1 probe 300 Vrms CAUTION A Do not float the oscilloscope chassis Defeating the ground connection and floating the oscilloscope chassis will probably result in inaccurate measurements and may also cause equipment damage The probe ground lead is connected to the oscilloscope chassis and the ground wire in the power cord If you need to measure between two live points use a differential probe with sufficient dynamic range Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Getting Started 1 WARNING Do not negate the protective action of the ground connection to the
292. ve translations for the English front panel keys and label text are available in 10 languages The appropriate overlay is included when the localization option is chosen at time of purchase To install a front panel overlay 1 Gently pull on the front panel knobs to remove them 2 Insert the overlay s side tabs into the slots on the front panel 3 Reinstall the front panel knobs Front panel overlays may be ordered from www parts keysight com using the following part numbers Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 37 1 Getting Started Language 2 Channel Overlay 4 Channel Overlay French 75019 94324 75019 94316 German 75019 94326 75019 94318 Italian 75019 94323 75019 94331 Japanese 75019 94311 75019 94312 Korean 75019 94329 75019 94321 Polish 75019 94335 75019 94334 Portuguese 75019 94327 75019 94319 Russian 75019 94322 75019 94315 Simplified Chinese 75019 94328 75019 94320 Spanish 75019 94325 75019 94317 Thai 75019 94333 75019 94332 Traditional Chinese 75019 94330 75019 94310 Learn the Rear Panel Connectors 38 For the following figure refer to the numbered descriptions in the table that follows Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Getting Started 1 8 USB Device port LTA 3 LAN VGA 2i use XO 7 USB Host port option module van DEVICE HOST TRIG_O
293. veform The high pass filter in the External Trigger input path is 50 Hz for all models Use AC coupling to get a stable edge trigger when your waveform has a large DC offset LF low frequency Reject coupling adds a high pass filter with the 3 dB point at 50 kHz in series with the trigger waveform 0 dB 3 dB down point Pass Band DC 50 kHz Low frequency reject removes any unwanted low frequency components from a trigger waveform such as power line frequencies etc that can interfere with proper triggering Use LF Reject coupling to get a stable edge trigger when your waveform has low frequency noise TV coupling is normally grayed out but is automatically selected when TV trigger is enabled in the Trigger Menu Note that Trigger Coupling is independent of Channel Coupling see To specify channel coupling on page 59 144 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Trigger Mode Coupling 11 To enable or disable trigger noise rejection Noise Rej adds additional hysteresis to the trigger circuitry By increasing the trigger hysteresis band you reduce the possibility of triggering on noise However this also decreases the trigger sensitivity so that a slightly larger signal is required to trigger the oscilloscope Press the Mode Coupling key 2 Inthe Trigger Mode and Coupling Menu press the Noise Rej softkey to enable or disable To enable or disable trigger HF Re
294. web interface 269 save segment 227 save setup files 225 save times data 228 Save to 230 save Quick Save 256 save recall from web interface 269 Save Recall key 35 saver screen 248 saving data 223 SCL I2C trigger 312 SCPI Commands window 267 screen image via web interface 271 screen saver 248 SDA 311 SDA I2C trigger 312 Search key 33 secure erase 233 segmented memory 161 segmented memory re arm time 163 segmented memory saving segments 227 select digital channels 91 select knob 91 Selected 246 selecting values 32 self test front panel 254 self test hardware 254 serial clock I2C trigger 312 343 Index serial data 311 serial data I2C trigger 312 serial decode controls 34 Serial key 34 serial number 254 261 service functions 251 Set all Digits softkey 126 setup files saving 225 setup automatic 87 setup default 27 setups recall 231 SGM 161 SGM license 283 shipping damage 21 shipping precautions 255 Sigma minimum 198 Simple Remote Front Panel 265 Simplified Chinese front panel overlays 38 Simplified Chinese user interface and Quick Help 42 sine waveform generator output 213 single acquisition 33 Single key 149 single shot acquisitions 143 single shot events 149 size 89 skew analog channel 62 slope trigger 121 Snapshot All measurements 178 snapshot all quick action 256 softkey labels 41
295. will be 1000 points rows in the spreadsheet per segment When saving all segments there are three header rows so the data for the first segment starts at row 4 The second segment s data starts at row 1004 The time column shows the time since the trigger on the first segment The top row shows the selected number of points per segment BIN files are a more efficient data transfer format than CSV or ASCII XY Use this file format for fastest data transfer Minimum and Maximum Values in CSV Files Explanation If you are running a Minimum or Maximum measurement the minimum and maximum values shown in the measurement display may not appear in the CSV file When the oscilloscope s sample rate is 4 GSa s a sample will be taken every 250 ps If the horizontal scale is set to 10 us div there will be 100 us of data displayed because there are ten divisions across the screen To find the total number of samples the oscilloscope will take 100 us x 4 GSa s 400K samples The oscilloscope is required to display those 400K samples using 640 pixel columns The oscilloscope will decimate the 400K samples to 640 pixel columns and this decimation keeps track of the min and max values of all the points that are represented by any given column Those min and max values will be displayed in that screen column A similar process is used to reduce the acquired data to produce a record usable for various analysis needs such as measurements and
296. x value This occurs when one or more don t cares X are combined with low 0 and high 1 logic levels in the pattern specification or when a transition indicator rising edge 4 or falling edge t are included in the pattern specification A byte that consists of all don t cares X will be displayed in the bus as a don t care X Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 93 6 Digital Channels Pattern Trigger Pattern Trigger pattern definition Pat By KEYSIGHT TECHNOLOGIE Acquisition 1 Channels 1 4 B 1 4 8 B EG Set all Digits Digital channel values at cursor See Pattern Trigger on page 124 for more information on Pattern triggering Digital channel signal fidelity Probe impedance and grounding Input Impedance 94 When using the mixed signal oscilloscope you may encounter problems that are related to probing These problems fall into two categories probe loading and probe grounding Probe loading problems generally affect the device under test while probe grounding problems affect the accuracy of the data to the measurement instrument The design of the probes minimizes the first problem while the second is easily addressed by good probing practices The logic probes are passive probes which offer high input impedance and high bandwidths They usually provide some attenuation of the signal to the oscilloscope typically 20 dB Keysi
297. y occur minimum and maximum value samples are kept in order to capture infrequent and narrow events at the expense of exaggerating any noise This mode displays all pulses that are at least as wide as the sample period For InfiniiVision 2000 X Series oscilloscopes which have a maximum sample rate of 2 GSa s a sample is taken every 500 ps sample period Glitch or Narrow Pulse Capture on page 156 Using Peak Detect Mode to Find a Glitch on page 158 Glitch or Narrow Pulse Capture A glitch is a rapid change in the waveform that is usually narrow as compared to the waveform Peak detect mode can be used to more easily view glitches or narrow pulses In peak detect mode narrow glitches and sharp edges are displayed more brightly than when in Normal acquire mode making them easier to see To characterize the glitch use the cursors or the automatic measurement capabilities of the oscilloscope Keysight InfinilVision 2000 X Series Oscilloscopes User s Guide Acquisition Control 12 KEYSIGHT TECHNO Acquisition Channels 10 0 1 10 0 1 Ace nu 4D Acq Mode Segmented Normal Es Figure 24 Sine With Glitch Normal Mode Channels oc 10 0 1 DC 10 0 1 Ace Menu 4D Acq Mode Segmented Peak Detect Figure 25 Sine With Glitch Peak Detect Mode Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 157 12 Acquisition Control Using Peak Detect Mode to Find a Glitch Connect a signal to the os
298. y and select any analog channel as the video trigger source The selected trigger source is displayed in the upper right corner of the display Turning the Trigger Level knob does not change the trigger level because the trigger level is automatically set to the sync pulse Trigger coupling is automatically set to TV in the Trigger Mode and Coupling Menu Provide Correct Matching Many video signals are produced from 75 Q sources To provide correct matching to these sources a 75 Q terminator such as a Keysight 11094B should be connected to the oscilloscope input 4 Press the sync polarity softkey to set the Video trigger to either positive IL or negative LJ sync polarity 5 Press the Settings softkey Video Trigger Menu Standard Mode Field Holdoff NTSC semana Field 0 Oflds Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Triggers 10 6 Inthe Video Trigger Menu press the Standard softkey to set the video standard The oscilloscope supports triggering on the following television TV and video standards SEUETC Type Sync Pulse NTSC Interlaced Bi level PAL Interlaced Bi level PAL M Interlaced Bi level SECAM Interlaced Bi level 7 Press the Auto Setup softkey to automatically set up the oscilloscope for the selected Source and Standard Source channel vertical scaling is set to 140 mV div Source channel offset is set to 245 mV Source channel is turned on Trigger type is
299. y knob to set the number of bits Bits in the serial data string The number of bits in the string can be set anywhere from 4 bits to 64 bits The data values for the serial string are displayed in the MOSI MISO Data string in the waveform area Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 323 24 2C SPI Triggering and Serial Decode 6 For each bit in the MOSI MISO Data string a Press the Bit softkey then turn the Entry knob to select the bit location As you rotate the Entry knob the bit is highlighted in the Data string shown in the waveform area b Press the 01 X softkey to set the bit selected in the Bit softkey to 0 low 1 high or X don t care 5 00V 5 00 5 00 5 00V SP 1 44 KEYSIGHT TECHNOLOGIES Acquisition Channels Trigger Paint eal a Ce S FF FF FF FF 7 FFX FF 02XFF FF FF 02 10 4D 53 4i 03 10 00 00 X 06X 05 FFXO2 20 21 Set all Bits Display Info 1 The Set all Bits softkey will set all bits in the data string to the value of the 01 X softkey For SPI decode information see SP Serial Decode on page 324 SPI Serial Decode To set up the oscilloscope to capture SPI signals see Setup for SPI Signals on page 319 324 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide I2C SPI Triggering and Serial Decode 24 For SPI triggering setup see SPI Triggering on page 323 To set up SPI serial decode 1 Press Serial to display
300. y option This is the time in seconds since the first trigger A 32 bit unsigned integer This is the segment number Only used when saving multiple segments Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 287 22 Reference Waveform Data A waveform may have more than one data set Each waveform data set will have a Header waveform data header The waveform data header consists of information about the waveform data set This header is stored immediately before the data set Waveform Data A 32 bit integer that is the size of the waveform data header Header Size Buffer Type A 16 bit short that is the type of waveform data stored in the file 0Q Unknown data 1 Normal 32 bit float data 2 Maximum float data 3 Minimun float data 4 Not used in InfiniiVision oscilloscopes 5 Not used in InfiniiVision oscilloscopes 6 Digital unsigned 8 bit char data for digital channels Bytes Per Point A 16 bit short that is the number of bytes per data point Buffer Size A 32 bit integer that is the size of the buffer required to hold the data points Example Program for Reading Binary Data To find an example program for reading binary data direct your web browser to www keysight com find 2000X Series examples and select Example Program for Reading Binary Data Examples of Binary Files Single Acquisition The following picture shows a binary file of a single ac
301. your video signals or to measure worst case distortion trigger on the odd or even fields When Field 1 is selected the oscilloscope triggers on color fields 1 or 3 When Field 2 is selected the oscilloscope triggers on color fields 2 or 4 1 Press the Trigger key 2 Inthe Trigger Menu press the Trigger softkey then turn the Entry knob to select Video 3 Press the Settings softkey then press the Standard softkey to select the appropriate TV standard 4 Press the Mode softkey and select Field1 or Field2 The trigger circuits look for the position of the start of Vertical Sync to determine the field But this definition of field does not take into consideration the phase of the reference subcarrier When Field 1 is selected the trigger system will find any field where the vertical sync starts on Line 4 In the case of NTSC video the 136 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Triggers 10 oscilloscope will trigger on color field 1 alternating with color field 3 see the following figure This setup can be used to measure the envelope of the reference burst 424 0 500 08 Channels Video Trigger Menu Standard Mode Field Holdoff NTSC Field1 O 0flds Figure 19 Triggering on Color Field 1 Alternating with Color Field 3 If a more detailed analysis is required then only one color field should be selected to be the trigger You can do this by using the Field Holdoff softkey in the Video

Download Pdf Manuals

image

Related Search

Related Contents

Electrolux EWT 12420 W User's Manual    Koolatron D25 Use and Care Manual  MESA MSC2120ECSD Installation Guide : Free Download, Borrow, and Streaming : Internet Archive  

Copyright © All rights reserved.
Failed to retrieve file