1. 5 s and 40 s 3 Installing or replacing the lamp Never replace a lamp without first disconnecting the lamp base from the ballast unit Please observe the operating instructions of the lamp 4 Connecting or replacing the battery The ballast unit BB 200 is available in 3 variants 1 with slide lock system By pressing the security mechanism at the side of the slide lock system the battery can be inserted respectively removed 2 for Cannon 12 2 pole plug To connect respectively disconnect the ballast unit from the battery tighten or release the cap nut on the plug Please observe Never pull on the cable itself pull only on the plug housing 3 for XLR 4 pole plug To connect the ballast unit to the battery just plug in the corresponding connection to disconnect the security mechanism on the socket must be pressed so that the plug can be pulled out Please observe Never pull on the cable itself pull only on the plug housing 5 LED Display Green LED is lit continuously normal operating mode Green LED is flashing the battery voltage has dropped to 26V 22V The lamp is now operated at a reduced power level according to the diagram below Red LED is blinking the battery voltage has dropped to 22V 19V or the thermoprotection is activated reducing the power continuously down to 60 The power reduction enables the user to recognize the situation and delays the final shut down e Red LED is lit continu
2. Operating instructions kobold by bron BB200 www bron kobold com Operating instructions kobold BB 200 Before use Please read all the information contained in these operating instructions carefully They contain important details on the use safety and maintenance of the lighting equipment Keep these operating instructions in a safe place and pass them on to further users if necessary Observe the safety instructions Important safety instructions When using your lighting equipment basic safety precautions should always be followed including the following 1 Read and understand all instructions before using 2 Close supervision is necessary when any appliance is used near children Do not leave appliance unattended while in use Animals must be kept away from the appliance 3 The lamp and the accessories mounted onto the lamp may heat up to high temperatures so please handle with care 4 Do not operate lamp with a damaged cable or if the lamp has been dropped or damaged until it has been examined by a qualified serviceman 5 Position the cable so that it will not be tripped over pulled or make contact with hot surfaces 6 To reduce the risk of electric shock never open this unit take it to a qualified serviceman when service or repair work is required Incorrect reassembly can cause electric shock when the equipment is subsequently used 7 The use of an accessory attachment not recommended by the man
3. ballast unit is designed for 30V batteries but it can also be used with 24V batteries In this case the output power is automatically limited to 170W maximum The ballast unit is switched on by means of the on off switch on the lamp The green LED lights up operating indicator The ballast unit is equipped with an automatic heat up device so that the operating temperature is achieved after only 1 minute In this period the unit should only be switched off if absolutely necessary in order to prolong the service life of the lamp The optimal colour temperature is achieved after approx 3 minutes of operation If the lamp cannot be triggered the ballast unit stops the trigger process after about 1 5 s and the red LED lights up A new attempt to trigger can be initiated by operating the on off switch again After 10 attempts the unit will block the trigger circuit for a cool down period of approx 30 seconds After that further attempts are possible Ensure that the ventilation slots are not covered during operation 2 Power regulation The required light output can be set 100 60 adjustment range with the power regulator It should be noted that the colour temperature can change with the power output depending on the type of lamp used During heat up the power is automatically set to full until the operating temperature is achieved The blocking time of the dimmer depends on the lamp temperature when switching on and can vary between
4. ossible up to Storage temperature Lamp frequency Power variation Stabilization Fuse Dimensions Weight Alarm functions LED display Protection Standards Lamp types BB 200 variants With slide lock system For Cannon S12 2 pole plug For XLR 4 pole plug 200W 26V 34V DC 22V 25V DC lt 19V gt 22V 215W 0 3 mA 93 5 to 45 C 45 to 60 C 20 to 80 C 400Hz 100 to 60 power stabilizer with automatic heat up device achieving lamp operating temperature in 1 minute 10 AF 65 x 105 x 165 mm 750 g low battery voltage ignition overload protection temperature monitor technical fault lamp shorted green operating indicator red warning IP 20 insulation class II EC directives 73 23 89 336 output limited to 170W autom power reduction to 50 Osram HMI 200 W SE Philips MSR 200 HR Sylvania BA 200 SE HR Art No 742 0194 Art No 742 0193 Art No 742 0191 cE Bron Elektronik AG CH 4123 Allschwil Schweiz Switzerland Printed in Switzerland 11 03
5. ously the unit has stopped operating for one of the following reasons 1 The battery voltage has dropped below 19V 2 The overload protection has stopped the trigger circuit after approx 10 unsuccessful attempts to trigger After 30 seconds further attempts are possible 3 The temperature of the ballast unit has exceeded a safe limit 4 Short circuit in the lamp 5 Technical fault Power W 250 200 150 100 4 50 If the red LED is lit continuously the lamp must be switched off This display is shown for a few seconds only Then the red LED extinguishes in order to save battery current Power f U Batterie 5 10 15 20 25 30 U Batterie V 35 6 Technical data Operation of kobold equipment with motor generators Kobold equipment is basically suitable for operation with motor generators provided that the supply voltage remains within the tolerance limits of 200 264V or 95 135V respectively under all load conditions including capacitive load Experience shows that this usually requires electronically stabilized motor generators When connected to unstabilized motor generators voltage peaks of 300V and over could be observed This may cause damage for which we cannot assume any responsibility Rated output Voltage range 30V battery Voltage range 24V battery Automatic cut off at Ignition possible from Power consumption Current consumption standby Efficiency Ambient temperature Operation p
6. ufacturer may cause a risk of fire electric shock or injury to persons 8 The ballast unit BB 200 is fully compatible with the other kobold 200 W daylight systems Attention Read before starting up Protect the unit from water To ensure maximum service life of the lamp allow it to heat up for approx 1 minute without interruption Always disconnect the ballast unit from the battery before cleaning or servicing and when not in use Never pull on the cable itself pull only on the plug housing To prevent overheating do not obstruct the free air flow through the ventilation slots during operation To reduce the risk of electric shock do not disassemble the equipment but take it to a qualified serviceman when service or repair work is required Incorrect reassembly can cause electric shock when the equipment is subsequently used Before replacing fuses or the lamp disconnect the ballast unit from the battery The equipment is not suitable for use in explosion hazard areas Do not operate the lamp without a safety glass or with a damaged safety glass Lamps may burst the safety glass will retain the hot fragments Like natural daylight HMI MSR light contains a certain proportion of UV radiation The safety glass reduces the UV content to safe levels for normal operating distances When used at close operating distance limit the exposure time of unprotected skin 1 Starting up Connect the ballast unit to the battery The
Download Pdf Manuals
Related Search
English english to spanish english to russian english to french english to japanese english to korean english to german english english to spanish translation english to tamil english to chinese english to tagalog english to italian english to hindi english to arabic english to latin english to tagalog translator english bulldog english to telugu english to marathi english to vietnamese english to spanish google translate english alphabet english breakfast english language english keyboard