        Operating instructions GEFA / DOMINO valves series AT 200F ATEX
         Contents
1.     If the valve shall be grounded directly  then the grounding latches can be connected to the gate on the antistatic  device    Check the function of the valve  If the function valve might not work properly  the valve must be replaced     Pneumatically operated valves    Before initial operation  all the air lines provided by the customer as well as the pneumatic control valves must  be thoroughly blown and also cleaned if necessary    We recommend the use of lightly oiled compressed air to actuate the cylinder  In operation  1 2 drops per 1000  litres of air will be sufficient    Unless explicitly stated otherwise when ordering  pneumatic control valves installed by us are supplied without  accessories such as chokes or silencers  The stipulations at the customer   s site must be followed   Pneumatically operated valves should not be closed suddenly  as otherwise there is a risk of pressure shock     Hydraulically operated valves    Before initial operation  all the control lines provided by the customer must be thoroughly cleaned   Hydraulically operated valves should not be closed suddenly  as otherwise there is a risk of pressure shocks   Choker valves set at the factory must not be altered     AT200F ATEX Betriebsanleitung  GB  doc  ZA  21 09 2007 5   8    Operating instructions CSF A    GEFA   DOMINO valve AT 200F  ATEX II 1D 2DG c     PROCESSTECHNIK GMBH    Electrically operated valves    Closing may be done exclusively according to our instructions  as follows     o
2.  AT 200F  ATEX II 1D 2DG c  PROCESSTECHNIK GMBH    e Lubrication of valves with hand wheel operation   The spindle must always be kept well greased and free of dirt  The greasing points on the hand wheel bearing  must be regreased regularly depending on the conditions of operation and use    e Valves with pneumatic or hydraulic operation   The piston rod should be clean and free of dirt  A self lubricating rod seal is used as standard with pneumatic  cylinders with damping  All the seals should be replaced if these cylinders leak    e Electrically operated valves   The spindle must always be kept well greased and free of dirt  The greasing points on the actuator must be  checked  The respective instructions for use of the actuator manufacturer are binding    e At every routine maintenance the antistatic device at the gate has to be tested regarding damages and has to  be replaced if damages were found     Before starting up after maintenance or repair   e Check that screw connections are tightly fitted   e Ensure that all parts removed have been re assembled     Behavior after failure    After a break down  e g  explosion  the valve has to be function tested by suitably qualified personnel   This is even valid if permitted limits  e g  explosion pressure  were not reached   It is recommended to let the manufacturer check the valve     Final remarks    The details given here correspond to the latest state of our knowledge and  in connection with the technical  documentation  t
3.  in particular the valve plate  spindle and piston rod  must be  free of dust and dirt and  if necessary  well lubricated with a suitable lubricant before being used for the first  time    Damage to the protected surfaces arising during installation or transport must be repaired by an expert   Damage of this type is not covered by the warranty    Protection of the Valve   If there is construction work still going on near or above the valves  they must be covered to protect them  against this construction work    When painting the installation  the spindle  electrical components and the plate projecting from the housing  when the valve is open must not be painted  Any solvents used to remove unwanted paint must not come into  contact with the seals under any circumstances  This applies especially to the area where the valve plate  projects from the housing  If the installation is to be first cleaned by sand blasting  the valves must be covered  with special care    Debris from sand blasting  and especially sand blasting grit  which gets into those parts of the installation that  will be in contact with the valve during subsequent operation of the installation  must be removed carefully   Sand blasting grit can destroy the valve plates and seals within a very short time    The possible locations for installing the valve must be selected such that  surfaces A and B are freely accessible for both sides to allow the seals to be  readjusted if necessary    Ensure that there is the 
4.  of moving pipelines the fastening of the actuator must not be rigid   Pneumatic or hydraulic actuators must be operated with the agreed design pressure  The actuator   s maximum  permissible operating pressure must be observed    Check that all the required connections  e g  electrical connections  compressed air hose connections  have  been plugged in and the connectors are secure    When shutting off powdery or granular media  ensure that any wetness or humidity caused by the installation  work and which might cause a subsequent caking of the medium must be thoroughly removed before the  installation is started up when using the medium  Malfunctions of the valve caused by agglutination or caking of  powdery media are not covered by the warranty    Danger by static charging    To protect against static charging the valve has to be grounded    The gate is connected conductively with the body by an antistatic device    Since the housings are plastic coated  a conductive connection of the pipe flange via a respective seal is not  guaranteed    For a conductive connection between valve and pipe the thread blind holes in the upper area of the body can be  used  Those thread blind holes are not coated    To ensure a durable conductive connection toothed lock washers have to be placed under at least two screw  heads of the screws for the thread blind holes    It has to be taken into account that the pipe flange is free of isolating coatings in the area of these tooth lock  washers
5.  the block profile transverse seal  or  after a prolonged period of disuse  and this still persists even after operating the valve several times  then the  seal can easily be re tensioned while the valve is still installed  The valve should not  however  be under full  operating pressure when this work is done    Minor leaks    Minor leaks can be eliminated by tightening the  packing hole screws  A   If this does produce any  significant improvement  remove the packing hole  screws  A  and apply the packing material  B  by  means of the packing tool  C  until the valve is  tight  In the case of valves sealed with a  transverse seal  take care that the packing tool is  pushed into the hole provided in the seal and the  packing material is compressed between the  seals  The packing hole screws  A  should be  tightened up again by about 3 turns    Major leaks    Major leaks are an indication of worn or damaged  seals    If the leak cannot be eliminated by the packing  method described above    the valve sealing system must be replaced   Replacement of the seals is to take place according to the operating instructions  Maintenance   Seal  Replacement Series AT   It is recommended to have the manufacturer carry out the seal replacement    Danger  In the event of heavily worn or damaged seals the resistance to explosive pressure and ignition are not  guaranteed        AT200F ATEX Betriebsanleitung  GB  doc  ZA  21 09 2007 7   8    Operating instructions G CSF A  GEFA   DOMINO valve
6. G Cs am Operating instructions    PROCESSTECHNIK emeh GEFA   DOMINO valves  GermaniastraBe 28 Postfach 700110 series AT 200F    44379 Dortmund 44371 Dortmund    Emal gefa getacom emet wmwgeracom ATEX II 1D 2DGc       Product description   The GEFA valves series AT200F are provided for use in the area of solid substances  The valve is usable as a  product tight valve    Valves of the AT 200 series can be installed between flanges or as inlet   outlet valves    It has to be taken into account that a valve which is manufactured for a certain flange norm usually cannot be used  for other flanges  It has to be checked with the manufacturer if pipe flanges can be used which do not correspond  to the ordering specification     Maximum operating excess pressure  pmax     Independent of the PN level of the valves  the following maximum operating excess pressures  pmax  must be  heeded        Danger  The maximum operating excess pressure refers to the working pressure of the valve    The maximum or reduced explosion pressure usually exceeds the working pressure several times over    For this reason  the limits of application according to 94 9 EG must always be observed    Depending on the medium and operating conditions it can be necessary to reduce the working pressure  considerably in order not to exceed the limits of application according to 94 9 EG in the event of an explosion     Limits of application acc  94 9 EC    The valves have been designed for use in potentially explosive a
7. ate position      e For parts mounted on the valves  such as electrical actuators  limit switches  valves  etc   the corresponding  storage instructions of the relevant manufacturers shall have priority     Valve housing coating   Danger  The coating of the valve housing has been designed in such a way as to prevent danger due to static  charge  For this reason  no changes may be made to the coating of the valve housing  If the coating of the valve is  changed  ignitable discharge could occur as a result of static charge     Actuators    Note  actuators and accessory parts mounted or provided by the customer  e g  solenoid valves  must correspond  to the outer device category of the valve  3D  3G  2D or 2G      AT200F ATEX Betriebsanleitung  GB  doc  ZA  21 09 2007 3   8    Operating instructions CSF A    GEFA   DOMINO valve AT 200F  ATEX II 1D 2DG c     PROCESSTECHNIK GMBH    Installation    Observe the maintenance and repair instructions for the individual components    Danger  moving parts may cause injury    Danger  Operation of electrically  pneumatically  or hydraulically operated valves that have not yet been  installed is not permitted    To prevent the danger of stumbling  Place all connections  cable  hose pipes and tubing  in such a way that they  will not cause any stumbling  cable ducts  bridges etc     Before the final installation of the valves  any corrosion preventative that has been applied as per section 2 2  above must be thoroughly removed  All parts  and
8. cturer     Normal operation    The valve should only be operated by persons who are trained and authorized to do so  and who know the  operating instructions and work accordingly    Danger  It must be guaranteed that the feed flow is free from any foreign bodies that could act as an ignition  source    Danger  Removal of the protective cover  except for installation  maintenance and   or repair work  is not  permitted    Danger  The user has the responsibility for taking care that all risks of accident are avoided by taking suitable  precautions in the danger zone for valves used as inlet valves   The legal stipulations are to be followed here    Before entering the danger area it must be guaranteed that the valve is completely closed  and thus ignition   proof     For this reason the valves are generally to be designed with an end position indicator    Used end position indicators  e g  limit switch or proximity switch  must have high safety standard against  malfunctions  e g  switches featuring with positive opening contacts     Visual control of the gate position must be carried out even if end position is indicated by limit switches    For this purpose the factory made marking on the gate can be used  The marking is located on the right side at  the inlet side of the valve  The gate has reached the position    CLOSED    if the line below the arrow is in  alignment with the upper edge of the valve body    Valves with covered gates have to be equipped with a visual positio
9. ection between the temperature of the conducted medium  the temperature class and the device category  can be seen in the following table     Device Temperature of the  operating medium Temperature class  category   C     II 3G or II 2G    Il 3G or II 2G  II 3G or Il 2G SS Fl  II 3G or II 2G       The temperature of the operating medium must not exceed 150   C on account of the seals used    The ignition temperature of whirled up dust must be at least 1 5 times the temperature of the conducted medium   The glow temperature of dusts deposited on the valve must be at least 75   C greater than the temperature of the  operating medium  whereby the thickness of the dust layer must not exceed 5 mm     Marking acc  94 9 EC    The valves are marked with the following details     GEFA Dortmund   AT 200F   Nominal width   PN level   Maximum operating excess pressure  pmax    Permissible environmental temperature   20   C  lt  Ta  lt   60   C  Serial number   Month and year of manufacture   Certificate number    CE 0158    Explosion protection mark         II 1D 3DG c  Category 1D inside the valve   Category 3D or 3G outside the valve     or         II 1D 2DG c  Category 1D inside the valve   Category 2D or 2G outside the valve     Operator   s duty of care   GEFA valves are designed and manufactured after careful selection of the standards and technical specifications to  be met  They are state of the art and allow the maximum level of safety during operation    Design modifications ma
10. enance or repair  ensure that any parts of the valve which may be touched have  cooled to room temperature    Danger  Check whether the pipeline has been rendered depressurized and is empty    Danger  Check whether pneumatic or hydraulic actuators have been rendered depressurized    Danger  Before starting maintenance or repair work  the pneumatic or hydraulic cylinders and the piping system  must be checked for residual energy  e g  pressure buffer     Danger  Automatic or remotely operated valves must be disconnected from the automatic operation system or  remote control system for the duration of the maintenance or repair work    Danger  Pneumatic cylinders equipped with an opening or closing spring may only be disassembled at the  factory of the manufacturer  It is important to observe the maintenance and repair instructions    Danger  Maintenance work for parts which are in contact with dangerous materials or liquids should only be  carried out by persons wearing suitable protection clothes    Only original spare parts should be used    Readjusting the seal    During prolonged storage and in the event of larger temperature fluctuations  the sealing material of the seal of  the narrow face may shrink or else release air trapped in the seal and thus can cause minor leakages on the  narrow face of the plate  If any leakage is found in the transverse seal in initial operation during the pressure  test or after readjusting the seal  as per the instructions for installation of
11. he purpose of providing information about our products and their range of applications    They are not meant to guarantee particular features of the products or their suitability for specific applications   Any existing copyrights and patent rights must be taken into consideration  We guarantee the quality within the  scope of our terms and conditions of sale     We reserve the right to make changes and improvements     status  2007 09 21    AT200F ATEX Betriebsanleitung  GB  doc  ZA  21 09 2007 8   8    
12. lignment    Before the flange screws at the area of the thread blind holes of the valve are tightened  the through screws  lying besides have to be tightend        Tighten the flange screws crosswise using the stipulated torque    The tightening moment depends on the seat material chosen    If there are no details available  the following reference values can be used   M16   125 Nm M20   240 Nm M24   415 Nm    M27   610 Nm M30   830 Nm M33   1100 Nm    AT200F ATEX Betriebsanleitung  GB  doc  ZA  21 09 2007 4   8    Operating instructions CSF A    GEFA   DOMINO valve AT 200F  ATEX II 1D 2DG c     PROCESSTECHNIK GMBH    Putting into operation    Flush the pipe and valve and clean them of any impurities  e g  welding residue     Before finally putting the valves into service  all the important elements  plate  spindle  piston rod  etc   must be  cleaned thoroughly  Any damage to the plate  especially to the seal as a result of sand blasting debris or  welding beads  external rust  etc   is not covered by the warranty    Cleaning agents that include solvents especially those based on aromatic hydrocarbons  thinners  petroleum  spirit and the like  must not be allowed to get into contact with the seal    Actuators must be mounted in alignment to the valve stem  Wrong mounting will lead to a higher wear of the  stem packing or cause leakage    The mounted actuator must not cause a thrust load on the valve shaft  If necessary the actuator must be  fastened   supported  NOTE  In case
13. n indicator              If the valve is seldom operated  and especially in the case of automatic valves  a test run should be made at  least every 3 months to ensure permanent readiness for use and to avoid deposits from becoming baked on     AT200F ATEX Betriebsanleitung  GB  doc  ZA  21 09 2007 6   8    Operating instructions CSF A    GEFA   DOMINO valve AT 200F  ATEX II 1D 2DG c     PROCESSTECHNIK GMBH    Maintenance and repair    Maintenance should only be carried out by qualified and authorized persons    Observe the maintenance and repair instructions for the individual components    Resistance to pressure impact and ignition    Resistance to pressure impact and ignition is achieved by the use of a sealing system as well as through  component design    Danger  In the event of heavily worn or damaged seals the resistance to explosive pressure and ignition are not  guaranteed    In order to guarantee the resistance to impact pressure and ignition  it is recommended to check the valve once  a year for leaks  Depending on conditions of operation and use a shorter inspection interval can be necessary   If leaks are found  these must be eliminated as indicated below    Danger  Removal of the protective cover  except for installation  maintenance and   or repair work  is not  permitted  After dismantling the protective cover to carry out installation  maintenance and   or repair work   attention should be paid to the movable parts of the valve    Danger  Before starting maint
14. necessary amount of space  200mm  available for  the packing tool C    Valves should normally be installed upright in horizontal pipelines  i e    actuator on top  and horizontally in vertical pipelines    The position of installation of the respective valve must be chosen so that  operation will be affected as little as possible by the medium    In the case of technically difficult installation conditions or in the case of custom made valves  please contact  the manufacturer if there is any doubt regarding the exact position of installation    The direction of flow must be according to the direction of the arrow in custom made valves    The pipes must not have any tension    Prior to the mounting of the valve flush the pipelines to remove all traces of soiling  welding residues etc   Check whether the flange clearance is in accordance with the face to face dimension of the valve    Before mounting the valve  the flanges are to be sufficiently spread using a suitable tool    Danger  From size 600 mm flange gaskets with supporting ring  e g  spiral wound gasket with outside ring   must be used  because the permitted explosion pressure is higher than the nominal pressure of the valve    flange connection   These gaskets are recommended for valves up to size 500 mm    Insert the valve and the gaskets between the flanges    Insert flange screws and nuts    Remove the spreader and hand tighten the screws    Check whether the valve  the gaskets and the counter flanges are in true a
15. nly switch off in the closing direction by using a torque switch     only switch off in the opening direction by using the path switch    the torque switch that is there serves as overload protection and must also be closed   In the case of freely programmable controllers  the path switch and torque switch must be connected  immediately before the contactor coils  For functional reasons  only self locking actuators may be used   Signal transfer at the path switch and torque switch to switch off the electrical actuator must be done in real  time  Signal chaining via multiple contactors or positioning units causes the drive units to run on and can lead to  the destruction of certain components   To avoid any risk of damage to the valve before it is operated electrically for the first time  move the plate by  hand to the middle position and only then operate the valve by means of the actuator   Check the phase sequence when connecting the power supply  The path switch and torque switch cannot  operate if the phase sequence is wrong   The electrical actuator may not be operated unless the torque and limit switch function correctly  The torque set  at the factory must not be changed  If it is necessary to do this in exceptional cases  only do so after consulting  the manufacturer   The heating and thermo switches must be connected without fail to avoid a buildup of condensation and  overheating of the motor  Follow the special operating instructions of the relevant actuator manufa
16. reas   The valves have been classified in Device Group II  The following device categories are valid          Il 1D 3DG c  Category 1D inside the valve   Category 3D or 3G outside the valve     or         II 1D 2DG c  Category 1D inside the valve   Category 2D or 2G outside the valve     DN 200     DN 600   The resistance to explosive pressure according to VDI 2263  Page 3 is 18 bar for the valve housing    Valves in closed position are igniting disruptive resistant up to 10 1 bar against organic dust explosions of dust  explosion class St1     DN 700   The resistance to explosive pressure according to VDI 2263  Page 3 is 10 1 bar for the valve housing    Valves in closed position are igniting disruptive resistant up to 10 1 bar against organic dust explosions of dust  explosion class St1     DN 800     DN 1000   The resistance to explosive pressure according to VDI 2263  Page 3 is 6 bar for the valve housing    Valves in closed position are igniting disruptive resistant up to 6 bar against organic dust explosions of dust  explosion class St1      AT200F ATEX Betriebsanleitung  GB  doc  ZA  21 09 2007 1   8    Operating instructions G CSF A  GEFA   DOMINO valve AT 200F  ATEX II 1D 2DG c  PROCESSTECHNIK GMBH    Maximum surface temperature    The surface temperature of the valve is determined by the temperature of the operating medium    Any increase in temperature due to frictional warmth is negligible  since the relative speed of the moving parts is  extremely low    The conn
17. solid box adapted to  the size of the valve taking into account the type of transport as well as any applicable regulations    e The valves must be suitably protected against external damage and atmospheric effects    e Depending on the duration of transportation and storage and also with regard to the climatic conditions   preservation must be made by means of gas treatment or by shrink wrapping and sealing the valve in  polyethylene film that also has an adequate amount of a desiccant such as silica gel placed inside     Storage   e The valves should be stored indoors in a dry place until final installation  All working parts must be suitably  covered to protect them against humidity  dust or other soiling    e Temperatures for storing    15  C to   30  C   e In humid rooms drying material respectively heating is necessary to avoid condensation of water    e During a longer period of storage or in the case of unfavourable storage conditions that might affect subsequent  functioning  all metallic bright surfaces such as the spindle  piston rod  and sealing surfaces must be effectively  protected against corrosion by means of a suitable and durable corrosion preventative    e The corrosion preventative applied at the factory must be checked for any damage in transit and suitably  repaired if needed    e Valves have to be protected against force  shock  blow  vibration etc      e During storage or transport the ball valve must be either in open or closed position  no intermedi
18. y only be carried out with the written permission of the manufacturer    Safety during operation can only be guaranteed if all of the required measures are taken  It is part of the operator   s  duty of care to plan and check these measures    The operator must particularly ensure that    e The valve is only used for its intended purpose    The material of the valve is selected acc  to the working conditions    The valve is only operated in a perfect  serviceable condition    The operating instructions are constantly available at the place where the valve is to be used    The valve is only operated  maintained and repaired by suitably qualified personnel     AT200F ATEX Betriebsanleitung  GB  doc  ZA  21 09 2007 2   8    Operating instructions CSF A  GEFA   DOMINO valve AT 200F  ATEX II 1D 2DG c  PROCESSTECHNIK GMBH    Transportation    To prevent damage and serious injury during transportation of the valve    e Only suitable and perfect load suspension devices and lifting tackle should be used    e Take the weight of the valve into account when selecting the load suspension device and lifting tackle    e Transportation routes are to be blocked and clearly marked so that unauthorized persons cannot enter the  danger area    e Transportation work should only be carried out by qualified and authorized persons wearing suitable protection  clothes     To prevent damage of the valve    e The transportation of the valves to their final destination  building site  must be done in a 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Hospital Pediátrico Universitario  Manual de usuario Motorola moviles DM46xx  comfort - Stiebel Eltron  Consola 5540 IP  VIZIO VO32L User's Manual  TV Game Console 100 games in 1  Elite ERO-2008SC Use and Care Manual  User Guide  chalumeau à air chaud  Miele KF 9757 iD User's Manual    Copyright © All rights reserved. 