n Operating Instructions
Contents
1. Additional functions 3 d MENU CONFIGURATION TIME CONTROL TERMINALS 29 30 By pressing the OK key you can set up the potential free contacts on terminals 29 and 30 according to the wiring diagram with a time interval of between 1 and 30 days or with a weekly time programme You can select up to nine operation times between 00 00 and 23 59 This contact can be set up in such a way that it is only closed when in addition to the time programme the filter pump PARALLEL PUMP ON OFF is operating The operating times of the time programme can be erased und re programmed ADDITIONAL FUNCTIONS By pressing the OK key the additional functions from the settings menu can be hidden The operator cannot access them any more The additional functions remain as set and are active although they are not visible in the menu TIME OF DAY By pressing the OK key you can select by means of the arrow keys the current time Even after switching off the AS Control Plus the time is preserved by means of a back up CR2032 battery DATE By pressing the OK key you can select by means of the arrow keys the current date Even after switching off the AS Control Plus the date is preserved by means of a back up CR2032 battery START DELAY factory setting 10 seconds By pressing the OK key you can select a start time delay between 10 and 3600 seconds The start delay is always active if the power supply connected after a failure of the power supply whe
2. main drain irrespective of temperature and whether the pool cover is open or closed 3 Overflow tank operation The pool is always drained via the overflow channel irrespective of temperature and whether the pool cover is open or closed Filter key Auto filter operates according to the programmed filter time On filter operates permanently Off filter is switched off Heating key Auto heating operates according to the programmed filter time Off heating is switched oft On if this light Is lit the heating is operating The set temperature has not yet been reached 09 11 E AS Control Plus 5 By pressing the MODE key you enter the menu The additional functions are indicated in the menu with the Symbol MENU LANGUAGE Press the OK key and you can then select by means of the arrow key between German French Italian English and Spanish FILTER PUMP MENU OVERLOAD PROTECTION factory setting is OFF Press the OK key and you are then in the overload protection menu where you can first select if the overload protection is to be switched on or off If the OP is switched on by pressing the Menu filter pump E OK key the motor current will be measured displayed and saved for the connected pump If you decide to connect a different pump to the AS Control Plus you will need to determine the current for the new pump You can exit the display of the current by pressing the MODE key Once you have determined the current
3. operation is optimal because the pool water is drained via the overflow However with high water temperatures and low air temperatures there is a large amount of heat loss evaporation convection During operation with the pool covered open the pool water has to be circulated via the overflow 2 Economy mode In so called economy mode water is drained directly from the pool i e from one or more drains Pool gt pump gt pool Thus the water no longer flows via the overflow The heat loss is reduced considerably Economy mode is best suited to periods of cold weather or during a pool heat up period During periods of use the pool should always be run in overflow mode for reasons of security and hydraulic efficiency Limits of liability We do not assume any liability for the layout or safety of the drainage system The correct layout of the drainage system is the responsibility of the installation company The local regulations concerning the safety of drainage systems must be observed If there are no specific regulations we always recommend that drains with hair trap security be fitted As well as installing at least two drains with a distance of 1 5 m between them The suction speed of the drains should not exceed 1 2 m s The ideal position for drains is where the bathers cannot come into contact with them CAUTION incorrect drain installation can cause death Pump switched off If the pump is switched off or there Is a
4. 09 08 07 Start time delay 0 90 min rara lt ok gt yes lt Mode gt no Temp correction pool POF 2 100C Temp correction air cd O Ce 10 C ON OFF Temp sens air Serial number Save parameters Restore parameters Factory reset Caution factory reset Reset all parameters Menu layout with Efetelhareyar lmaelareidlelats Measure current Mode cancel ok start Tolerance 1 100 Overload lt ok gt yes lt Mode gt no Min temp air 50 20 C Hysteresis 0 1 5 0 C Activation heater Sample alarm OFF ON Min temperature pool 0 max pt minus 1 C Max temperature pool min pt minus 1 C 30 C Delay time 1 200 sec Clearrins time 1 200 sec Time limit max 1 200 min Delay 0 200 min DP alarm delay 10 10 C 1 00 00 gt 23 59 2 00 00 gt 23 59 3 00 00 gt 23 59 4 00 00 gt 23 59 5 00 00 gt 23 59 Fo Forced start filter pump DP Run dry protection filter pump 6 00 00 gt 23 59 7 00 00 gt 23 59 8 00 00 gt 23 59 9 00 00 gt 23 59 Reset now lt MODE gt or lt OK gt lt ok gt yes Mode gt no
5. ALA ae sul ofseg O OAICA ysemyoeg obsag u01 93 01d 10 0W 9IUOJD9 3 diagram Q AS Control Plus iring pump 230 V Caution Only 1 filter pump can be connected 230 VAC or 400 VAC Filte 400 VAC Mains power 09 11 E ASControl Plus 11 Remove card Language Filter pump menu Heating menu Menu backwash Menu ECO programme Configuration Additional functions 12 ASControl Plus 03 12 E d ddd d Vu vy Hysteresis 0 1 10 C d ddd y d d Please wait All open files will be saved Italian Polish German French English Overcurrent protection Filter timer vee Ne e Ne e Ne Filtertime tank Clear timerdata Setpoint NAVIDAD Confirm erase times Frost guard Hysteresis Extra filtertime Extratime cl 24 25 Extratime cl 31 33 Heater priority Temp difference U OFF Test backflushing Backflushing Weekly X days Gutter tank Bottom drain 30 200 min Mon Sun 1 30 Backwash over Extratime tank Start at 00 00 Duration 1 30 min Delay Clear rinses OFF OFF Bottomfl at DP ZA Z ZA OFF Refill Time limit OFF ON Backflush at FD OFF C DP ommon OFF Common alarm Fo OFF Temperature Temp difference ECO programme mode Interval Timer cl 29 30 X days 1 30 days Extra functions Weekly Mon Sun OFF ON x Date Thu
6. Operating Instructions AS Control Plus Q AS Control Plus U dl dl baal a O dl aa ad 1 Q AS Control Plus E earn Pool 26 C Luft 34 C Trockenlauf Operating keys for setting the controls k Operating key ECO Inlet jets Slot for memory card Level probes Overflow tank Operating key Filter TAN E oO z S Overflow Run dry e 0 key protection protection Es Top up solenoid valve Introduction Thank you for choosing the AS Control Plus an innovative control system Incorporating a microprocessor It will dramatically improve the energy efficiency of overflow infinity swimming pools and avoid unnecessary energy losses On our test pool 50 m2 at 30 C water temperature in Switzerland we were able to demonstrate an energy saving of more than 20 000 kW equivalent to 2 000 litres of oil in a six month period May to October 2 AS Control Plus 09 11 E Contents Seite Comments on energy efficient controls 4 Control keys ECO Filter Heating 5 Menu functions Menu language filter pump menu 6 Heating menu 6 7 Backwash menu 7 Overflow tank menu ECO menu 8 Configuration menu 9 Important informations 10 Wiring diagram 11 Menu diagram 12 The AS Control Plus includes 1 Comments on energy efficient controls 2 Backwash and rinse controls 3 Heating controls with frost protection priority and delay slop safety 4 Level control of the overfl
7. The date and time are stored by means of a back up battery which has a life of three to four years By removing the four screws on the front panel you can access this battery without any special tools 09 11 E AS Control Plus 9 IMPORTANT INFORMATION Terminals 45 46 A manual switch ON OFF I can be connected to these two terminals By switching on the manual switch the filter pump is switched on and operation via the overflow channel is initiated It is advisable to mount this manual switch near the pool Terminals 52 53 These terminals can be used in conjunction with an air con ditioning unit When the contacts are closed circulation is via the main drain Terminals 70 71 These terminals can be connected with the swimming pool cover If these contacts are closed the ECO control if set to AUTO decides whether water will be circulated via the main drain or the overflow buffer tank The pre set filter times remain The potential free contact of the limit switch for the pool cover must be wired as follows pool cover on the pool closed limit switch contact Priorities The overflow filter time always has priority over other actions This means that when the unit is operating via the main drain in economy mode and the overflow filter times are active the controls switch to normal operation With the same objectives the following priorities are active Overflow filter time Manual switch terminals 45 46 Unit switch auto main d
8. ctory setting 10 00 am By pressing the OK key you can select the time at which the backwash starts DURATION factory setting 4 minutes By pressing the OK key you can select by means of the arrow keys the duration of the backwash between 1 and 30 minutes PAUSE factory setting 30 seconds By pressing the OK key you can select whether you want to pause between each individual step The duration of the pause can be set by means of the arrow keys to between 30 and 200 seconds RINSE factory setting OFF By pressing the OK key you can select by means of the arrow keys whether rinse is ON or OFF The duration of the rinse is between 1 and 200 seconds 09 11 E AS Control Plus 7 PAR RE Main drain with TRS OVERFLOW TANK MENU MAIN DRAIN AT DRY RUN PROTECTION Factory settings OFF The Besgo valve switches to main drain to avoid stopping the filtration pump because dry running empty overflow tank By pressing the OK key you can select this function ON and OFF TOP UP factory setting 90 minutes By pressing the OK key you can select whether the top up with fresh water should be time controlled or whether the top up is switched ON or OFF If the top up is time control led you can set the time limit for the top up between 1 and 999 minutes If the time limit has been reached and the water level has not reached its set height there is a problem with the top up system The top up switches off and the override alarm is trigg
9. d to the run on time for the filter gt DELAY STOP TERMINAL 24 25 factory setting O minutes By pressing the OK key the filter run on time can be adjusted between 1 and 200 minutes by means of the arrow keys gt DELAY STOP TERMINAL 31 33 factory setting O minutes By pressing the OK key the filter run on time can be adjusted between 1 and 200 minutes by means of the arrow keys gt HEATING PRIORITY factory setting OFF The heating can also be switched on outside the filter operation times By pressing the OK key the heating priority can be switched off or set to a temperature difference of between 1 C and 10 C for heating priority Menu backwash s 9 ague BACKWASH MEN U 3 TEST BACKWASH By pressing the OK key a backwash cycle can be started manually The progress of the backwash cycle can be observed on the display BACKWASH factory setting Friday By pressing the OK key the backwash can be completely switched off or the day of the week changed or an interval of 1 to 30 days between backwash cycles chosen by means of the arrow keys BACKWASH VIA factory setting overflow tank By pressing the OK key you can select by means of the arrow keys whether the backwash takes place via the overflow tank or the main drain gt DELAY STOP VIA OVERFLOW factory setting 30 minutes After every backwash there is a compulsory flow via the overflow channel The time is adjustable between 30 and 200 minutes START TIME fa
10. ered BACKWASH WITH FORCED START factory setting OFF Here you can select automatic backwash in the case of forced start In this way you can avoid too much water from draining away needlessly via the safety overflow The water can then be used again for another backwash Backwash can also be useful when heavy rain causes the overflow channel to be switched on thus causing an unnecessary waste of energy The delay time for the backwash can be set between 1 and 200 minutes gt GENERAL ALARM RUN DRY PROTECTION factory setting OFF By pressing the OK key you can select whether to trigger the general alarm in the case of a run dry situation If you activated the general alarm you can select a delay time of between 0 and 200 minutes When this time has expired the general alarm is triggered and a warning text appears in the blue display panel gt COLLECTVE ALARM FORCED START By pressing the OK key you can select whether to trigger the collective alarm in the case of a forced start situation If you activated the general alarm you can select a delay time of between 0 and 200 minutes When this time has expired the general alarm is triggered and a warning text appears in the blue display panel ECO PROGRAMME MENU ECO PROGRAMME MODE factory setting set temperature 20 C hysteresis 1 C Menu ECO programme gt By pressing the OK key you can select whether overflow operation is triggered when a specific ambient air temperat
11. n electricity cut the Besgo Economy mode valve will be in economy mode drain directly from the pool In this way the pool will not be emptied by mistake The water cannot be fed back into the overflow tank via jets and the filter That would lead to a loss of water If the water level in the collection tank were to rise so high that the water flowed over the edge of the buffer tank As additional security we recommend the installation of a non return valve into the inlet jet system as well as the incorpora tion of a forced start 5t probe in the collection tank Limits of liability We do not assume any liability for the cost of loss of water which is caused by the failure and or misuse of the AS Control Plus or the Besgo valves 4 AS Control Plus 09 11 E Diagram Overflow operation normal operation Economy mode 1 Overflow channel 2 Swimming pool 3 Main drain 7 4 6 7 4 Overflow tank 5 Besgo 3 way valve 6 Pump 7 Filter ECO switch There are three options 1 Auto operation In this position as a function of air and water temperatures it is deter mined whether drainage will take place directly via the pool economy mode or via the overflow channel As soon as the pool cover is opened the system goes into overflow mode The limit switch must be connec ted to terminals 70 71 2 Main drain operation economy mode The Besgo valve is always in the economy mode and drainage is via the
12. n the filter pump starts By means of the start delay the outputs for heating regulation and forced start are locked POOL TEMPERATURE CORRECTION By pressing the OK key you can adjust by means of the arrow keys the actual pool water temperature shown in the blue display by up to 10 C to 10 C This fine adjustment is useful when there is a difference between the measured and actual pool temperature due to the positioning of the temperature probe AIR TEMPERATURE CORRECTION By pressing the OK key you can adjust by means of the arrow keys the actual air temperature shown in the blue display by up to 10 C to 10 C This fine adjustment is useful when there is a difference between the measured and actual pool temperature due to the positioning of the temperature probe TEMPERATURE PROBE AIR factory settings ON By pressing OK you can enable or disable the indication of the value SERIAL NUMBER By pressing OK the Serial number will be indicated SAVE PARAMETERS By pressing OK all adjusted parameters will be written to the SD memory card READ PARAMETERS By pressing OK all saved parameters will be copied to the AS Control Plus FACTORY SETTINGS By pressing the OK key you can enter the factory settings menu If you answer the questions by pressing the OK key all the values which you have set can be reset to the original factory settings All set values are stored electronically and can be recovered even after a power failure
13. ow tank 5 Control of overflow tank backwash from the pool or the overflow tank 6 Energy efficiency control economy or overflow operation E Option All data for the previous ten month period are stored These can be downloaded onto a PC for analysis Technical data Connectors 71 connectors for inputs and outputs Relays 13 relays Electrical input 14 VA Electronic motor protection for 3 phase max 8 amps per phase Fuse 4 per 10 amps Display 4 layer multilayer IP Protection casing IP 65 Memory card option for data storage and evaluation via PC 512 MB for ten months Temperature probe laser trimmed semiconductor with 1 accuracy Water and air temperature probes are volt free Installation B The ASCP must be installed in a place free from humidity E Wiring of components must be carried out according to the ASCP wiring diagram E The regulations of the local electricity authorities must be observed 09 11 E AS Control Plus 3 Comments on the energy efficient control Overflow and economy mode The most original concept of the AS Control Plus is the tempera ture dependent switching between overflow and economy also 3 known as normal operation modes of operation and the resultant energy savings 1 Overflow operation In the so called overflow operation normal operation the water is circulated via the overflow channel gt overflow tank gt pump gt pool gt overflow channel The hydraulic
14. rain overflow tank Cover limit switch terminals 70 71 Eco programme set temperature and differential temperature oe T FROST MONITOR The frost protection mode only allows the heating to start if the filter pump started over the air temperature Hysteresis Example Set temperature 28 C hysteresis 1 C actual temperature 20 C In this example the heating will heat until 28 C and then switch off The heating will only switch on again when the water temperature drops below 27 C In this way you ensure that the temperature can only vary between 27 C and 28 C 10 AS Control Plus 09 11 E Overflow tank J9A09 YMS HUU L EA cee 3 QWe9 ID Ggysa ag ae Se S BE O Oo Dq SH CN Q O O RT eo ng o lt a S YOUMs Jenue geu ejuajod Buisod Wee 3A1 92 09 ne gt q 2 MOILIS O o BIA HEJS p39104 ysemyoeg gt ysemyoeg Leis gt 5 VDJIMS JINSS Ld K a E b 5 E 8 O NY 4 D 9 q d0 4 g 2 4 NO 4 O E b oc gt gt gt geu jejuajod Bunesy 0JUOD SUI via main drain Forced start Run dry protection Filter pump OFF A 0 2 uone ndal pue BuunsesiN Solenoid valve CLOSED Overflow protection Filter pumps OFF S Overflow protection Filter pump ON Level control JayeM Used SAIBA plous os N LIPE N L1 PE N lL AE ale Lal MOR aen D uleIp urew SAMBA Kem obsog EDS E S
15. ure is reached or when a specific temperature difference between ambient air and water temperatures is reached a Set temperature until the set temperature for air is reached the system remains in economy mode no current to the Besgo valve drained directly from the pool Only when the set temperature has been reached does the Besgo valve switch to overflow mode Setting 5 C to 40 C When solar covers are being used we recommend the use of the set temperature The set temperature should be set no higher than 20 C Ata temperature of 20 C in the shade there is considerable solar gain from the cover which is stored up under the cover in economy mode Temperatures under the cover can reach as much as 50 C and more This heat accumulation must be dissipated via the overflow channel b Temperature difference You can set a temperature difference of between 10 C and 10 C For example if a temperature difference of 2 C is set then the Besgo valve switches to operation via the main drain if the air temperature is 2 C higher than the water temperature If a temperature difference of 2 C is set then the Besgo valve only switches if the air temperature is 2 C lower than the water temperature CAUTION liability exclusion Some pool manufacturers polyester liner limit their warranty to use at temperatures of 30 to 35 C Potential damage to such pools or their covers is not covered by us S AS Control Plus 09 11 E
16. y Remove card Language HEATING MENU SET VALUE factory setting 25 C By pressing the OK key the set point of the water temperature can be selected by means of the arrow keys between 1 C and 40 C FROST PROTECTION factory setting OFF By pressing the OK key the frost protection can be selected as ON or OFF by means of the arrow keys In the ON position you can select by means of the OK key at which temperature 50 C to 20 C the frost protection switches on the filter pump The adjustable hysteresis temperature difference between ON and OFF gives the switch off signal Additionally a collective alarm can be intercon nected If you have a heating system connected you can select at which pool water temperature the heating should switch on and off 6 AS Control Plus 09 11 E gt HYSTERIS factory setting 0 5 C By pressing the OK key the hysteresis can be adjusted between 0 1 C and 5 C by means of the arrow keys Hysteresis means the number of degrees Celsius which separate the switching ON and OFF gt FILTER DELAY STOP factory setting 3 minutes By pressing the OK key the filter run on time can be adjusted between 1 and 200 minutes by means of the arrow keys The run on time can help to stop a build up of heat in the system by ensuring that the filter pump continues to run after the heating has been switched off If a run on time has been set via terminals 24 25 and or 31 33 this time will be adde
17. you can select the tolerance level to determine the per centage overload at which the overload protection is triggered and the filter pump switches off typically the tolerance is set to 15 When the thermo contact on the coil opens the filter pumps switches off immediately FILTER TIMES Factory settings 08 00 to 09 00 By pressing the OK key you can select up to five filter times per day when the water will be channelled via the overflow This is necessary since the water level is only controlled in the collection tank and not in the pool CAUTION You must circulate the water via the overflow for at least 30 to 60 minutes per day Only in this way can you measure and control the water level the measurement takes place in the overflow tank Additionally the correct water flow via the overflow channel will be re establis hed by entering the times for the overflow operation which will ensure proper circulation within the pool With public pools we recommend switching to over flow operation between one and two hours before the pool is occupied in order to ensure the correct water flow CAUTION Warranty exclusion Damage which is caused by too low a water level e g burnt out solar cover will not be covered by us CANCELING FILTER TIMES by pressing the OK key all filter times can be cancelled During this process you will be asked to confirm whether you really mean to cancel all filter times You confirm by pressing the OK ke