Home
SICOM3010G Industrial Ethernet Switch Hardware Installation
Contents
1. 15 SICOM3010G User s Manual v1 0 SFP slot SFP modular A per pe N S Optical fiber 7 A Sg i EL s Figure 15 SFP Optical Module 5 2 2 Gigabit SFP Electrical Module e Figure 16 shows an example of a Gigabit SFP electrical module Figure 16 Gigabit SFP Electrical Module The use of SFP electrical module While wiring first insert the SFP electrical module into the SFP slot in the switch and then plug the twisted pair into the SFP electrical module See Figure 17 16 SICOM3010G Users Manual v1 0 7 SFP slot SFP modular z Twisted pair _ i gt U ee TIA N Do Figure 17 SFP Electrical Module 5 3 1000Base X 10 100 1000Base T X Combo Port As shown in Figure 18 The 1000Base X 10 100 1000Base T X Combo port consists of one 1000 Base X port GX7 and one 10 100 1000Base T X Ethernet port GE7 and only one of the two ports can be used at one time Besides the 1000 Base X port has priority over 10 100 1000Base T X port Plug the optical fiber and the twisted pair into GX7 and GE7 respectively GX7 can communicate normally and the GE7 will be disabled automatically 1000Base X SFP port GXT 10 100 1000Base T X port 17 SICOM3010G User s Manual v1 0 Figure 18 Combo Port 10 100 1000Base X Ethernet port The instructions of 10 100 1000Base T X Ethernet port can refer to section 5 1 1000Base X port Insert Gigabit SFP optical module into 10
2. The default IP address is 192 168 0 2 Type the name of a program folder document or Internet resource and Windows will open it For vou Figure 30 Enter Telnet 3 Click OK to enter the Telnet configuration interface Type in a CLI command from Table 9 8 3 Web Access 1 Connect the Ethernet port on the PC to any RJ45 port on the switch 2 Input the IP address of the current switch in web browser the default IP is 28 SICOM3010G Users Manual v1 0 192 168 0 2 The Web interface access screen will appear as shown below in Figure 31 login with default user name admin and password 123 Layer 2 Switch PY User Name admin Password eee C Save the password Serial Number gt S3V2MXX System Name SWITCH Location Chongxin Mansion Building Xijing Road 3 Shiji ngshan District Beijing Contact 86 10 88798888 KYLAND TECHNOLOGY CO LTD All Rights Reserved 2009 Figure 31 Web Interface Access Screen Note We recommend IE version 8 0 or greater 9 Product Configuration Information The specific configuration models of SICOM3010G are shown in Table 10 Table 10 SICOM3010G Configuration SICOM3010G 2GX supports 2 1000Base X 10 100 1000Base T X 12DC Combo ports 6 10 100 1000Base T X RJ45 ports 24AC DCW supports 2 1000Base X 10 100 1000Base T X dual SICOM3010G 2GX Combo ports 21000Base X 10 100 1000Base T X redundant GE 2GX 6GE SFP ports 6 10 100
3. The driver Mini USB driver exe is in the software download folder which is on the supplied CD 2 Use the Console cable that is equipped with Mini USB connector at one end and USB connector at the other end to connect the Console interface on the switch with the USB port on PC 3 On Windows desktop click Start All programs Accessories gt Communications Hyper Terminal 25 SICOM3010G User s Manual v1 0 E lt om My Network oaee M Accessibility gt fa Communications gt HyperTerminal 2 fan Entertainment C Network Connections Recycle Bin ai System Tools Q Network Setup Wizard UJ Address Book E New Connection Wizard gt Administrator Calculator 32 Wireless Network Setup Wizard s aj K BI Command Prompt N Notepad Z Internet a My Documents 3 p Internet Explorer y Paint G E mail L4 My Recent Documents i Program Compatibility Wizard Outlook Express Set P m ccess and Default ia st Set Program Access l ca Remote Desktop Connection W Windows Catalog KY j See 7 Tour Windows XP amp Microsoft Update ae Windows Media Playe 5 3 Windows Explorer A WordPad Synchronize Tour Windows XP If A Games F Startul Files and Settings Tr a p A Wizard Internet Explorer wi msn joa Command Prompt 3 Outlook Express Remote Assistance Windows Media Player AllPrograms a WinRAR P Log Off o Turn OFF Computer s Networ
4. 50 5 pin 5 08mm power terminal block PWR1 PWR2 O OL 0 O NAN 1 2 3 4 Figure 21 5 pin 5 08mm spacing Plug in Terminal Block Table 7 5 Pin 508mm Power Terminal Block Contact Definition Contact Number DC Wiring Definition AC Wiring Definition PWR1 PWR1 L PWR PWR1 N PWR2 PWR2 N PWR2 L Wiring and mounting step 1 Take the power terminal block off the switch Step 2 Insert the power cable into the terminal block and connect the power cable Step 3 Put the terminal block back to the switch with the connected cable 5 6 Grounding Chassis grounding and power terminal grounding 20 SICOM3010G Users Manual v1 0 Protection ground Chassis ground FAULT 18 AVVG yellow green line Figure 22 Chassis Grounding and Power Terminal Grounding There is a grounding screw on the top panel of the SICOM3010G which is for chassis ground One end of the chassis grounding cable is connected with the grounding screw and the other end of the cable is reliably grounded The cross section area of chassis grounding cable should be more than 2 5mm The grounding resistance requirement lt 50 The grounding part in the 5 08mm power terminal block is called protection ground It is required to connect the chassis grounding part with the protection grounding part with supplied 18 AWG yellow green line to allow the switch to operate safely and precisely The dimension drawing of 1
5. Table 3 SICOMB010G Top Panel Number Peseripton Power supply terminal block 4 Mounting 4 1 Dimension Drawing Dimension Drawing for DIN Rail Mounting Unit mm Figure 4 DIN Rail Mounting Dimension Dimension Drawing for Panel Mounting Unit mm SICOM3010G User s Manual v1 0 36 37 06 5 Figure 5 Panel Mounting Dimension 4 2 Mounting Steps SICOM3010G DIN Rail Mounting The specific steps are as follows Step 1 Select the mounting position for SICOM3010G and ensure that there is adequate space Step 2 Insert the top of the DIN Rail into the slot of the DIN Rail connecting seat in the rear panel of SICOM3010G as shown below move the switch in the direction of arrow 2 to put the whole Din Rail into the seat check whether SICOM3010G is firmly mounted on the DIN Rail as shown below DIN Rail Figure 6 DIN Rail Mounting SICOM3010G User s Manual v1 0 Remove SICOM3010G from DIN Rail The specific steps are as follows step 1 Insert the screwdriver into the hole at the bottom of spring locking plate press the plate down to loosen the connection of DIN Rail and switch as shown in arrow 1 Step 2 Pull the SICOM3010G up in the direction of arrow 2 meanwhile remove the switch from the DIN Rail along the direction of arrow 3 Spring locking plate Figure 7 Dismounting e SICOM3010G Panel Mounting The specific steps are as follows Step 1 Select the mounting position
6. be applied extensively in wind power distribution network automation subway PIS AFC power SACDA wastewater treatment highway metallurgy hydroelectric power photovoltaic power railway CBTC factory automation intelligent transportation and many other industries SICOM3010G has a Mini USB Console port and supports Web Telnet and Console network management supports VCT Virtual Cable Test supports one key recovery SICOM3010G industrial Ethernet switch supports DIN Rail and panel mounting It provides 1000Base X 10 100 1000Base T X Combo ports 1000Base X 10 100 1000bBase 1T X SFP ports and 10 100 1000Base T X ports SICOM3010G Users Manual v1 0 3 Structure and Interface 3 1 Front Panel SICOM3010G 2GX GE 6GE Figure 1 Front Panel 1 Table 1 SICOM3010G 2GX GE 6GE Front Panel PWR1 Power 1 LED gt We Power LED Run Running LED SICOM3010G User s Manual v1 0 aa GX7 GE7 GX8 GE8 1000Base X 10 100 1000Base T X Combo port 9 GE1 GE6 10 100 1000Base T X RJ45 port SICOM3010G 2GX GE 2GX 6GE 1234 5 Figure 2 Front Panel 2 Table 2 SICOM3010G 2GX GE 2GX 6GE Front Panel SICOM3010G User s Manual v1 0 Run Running LED Ring Ring LED Reset Reset button Console Console interface yaw ate e owon fox 0 TON SFP een o Toer aace NCZI T0 Comoopon AR CORONA e rosenie OOO o 3 2 Top Panel l Ti N 4 N a SICOM3010G User s Manual v1 0 Figure 3 Top Panel
7. module to meet your requirements as shown in Table 11 5 2 1 Gigabit SFP Optical Module Figure 13 shows an example of a Gigabit SFP optical module Figure 13 Gigabit SFP Optical Module Gigabit SFP optical module is equipped with LC connector and each port consists of TX transmit port and RX receive port as shown in Figure 14 Connect the TX transmit port of switch A to the RX receive port of switch B and the RX receive port of switch A to the TX transmit port of switch B in order to transmit data between switch A and switch B as shown in Figure 14 14 SICOM3010G Users Manual v1 0 switchA SwitchB Figure 14 Gigabit SFP Optical Module Wiring Confirm Gigabit SFP optical module RX port and TX port 1 Insert the two connectors in one end of optical fiber into SFP optical module and then insert the two connectors in the other end of the optical fiber into SFP optical module of another switch to communicate 2 Check the corresponding port Link ACT indicator in the front panel Indicator flashing means link connectivity Indicator off means no link connectivity and it may be because of the incorrect link between RX port and TX port in SFP optical modules Try to swapping connectors in any one end of optical fiber The use of SFP optical module While wiring first insert the SFP optical module into the SFP slot in the switch and then plug the optical fiber into the SFP optical module See Figure 15
8. pin 1 and 2 are open pin 2 and 3 are closed Wiring and mounting Step 1 Take the alarm terminal block off the switch Step 2 Insert the cable for alarm output into the alarm terminal block according to the requirements and connect the cable Step 3 Put the alarm terminal block back to the switch with the connected cable 6 LED Indicators Table 8 Front Panel LED Desorption Running LED 23 SICOM3010G Users Manual v1 0 CPU is running abnormally or the switch is starting Run Blinking CPU is running normally 1HZ Ring Blinking Slave DT Ring mode B Root DRP mode Alarm PWR1 PWR2 Each RJ45 port has two indicators a yellow LED and a green LED The yellow LED indicates port rate while the green LED indicates port connection state 24 Link ACT Green SICOM3010G Users Manual v1 0 Reset Button Reset button supports reboot and restoring default configuration Push the reset button and hold for one second then release to reboot the switch Hold the reset button down for five seconds then release to restore default configuration including IP address and reboot the default IP address is 192 168 0 2 Note Don t hold the reset button down for more than 5 second to avoid restoring default configuration 8 Management Access Access the switch by one of the following three ways 8 1 Connected through Console Port 1 Install the driver for Mini USB onto your PC
9. 0 RJ45 Port Pin definition of 10 100 1000Base T X RJ45 port is shown in Table 4 Table 4 Pin Definition of 10 100 1000Base T X RJ45 Port me Transmit Receive Data TRDO Transmit Receive Data TRDO Transmit Receive Data Transmit Receive Data TRD2 TRD1 Transmit Receive Data TRD2 Transmit Receive Data TRD3 6 Transmit Receive Data TRD1 Transmit Receive Data TRDO Transmit Receive Data TRD3 Transmit Receive Data TRD2 12 SICOM3010G User s Manual v1 0 a Transmi Receive Data TRD3 Transmi Receive Data TRD2 Note means level polarity Wiring Sequence RJ45 Connetor RJ45 Connetor ET Straight through cable ME 1 Wiring sequence osm one woh a O oe wh Figure 11 10 100 1000M Straight through Cable Wiring RJ45 Connetor RJ45 Connetor IN Cross over cable Eie 1 Wiring sequence O M O gt 0 U Figure 12 10 100 1000M Cross over Cable Wiring Note The correlation between the pin of RJ45 connector and the color of twisted pair is 1 orange and white 2 orange 3 green and white 4 blue 5 blue and white 6 green 7 brown and white 8 white 13 SICOM3010G User s Manual v1 0 5 2 1000Base X 10 100 1000Base T X SFP Port 1000Base X 10 100 1000Base T X SFP port namely is 1000Base SFP slot Insert SFP module to SFP slot and then plug the twisted pair or the optical fiber into SFP module to transmit data Choose the model of SFP
10. 00Base X port and then plug the optical fiber into SFP module to transmit data Choose the model of SFP module that will meet your requirements as shown in Table 11 The instructions of Gigabit SFP optical module can refer to section 5 2 1 5 4 Console Interface Install the driver for Mini USB onto your PC The driver Mini USB driver exe is in the software download folder which is on the supplied CD Connect the USB port on the PC to the Console interface on the switch with cable equipped with Mini USB connector and USB connector at both ends Run Hyper Terminal software in WINDOWS operating system to connect to console software of the switch which will allow you to configure maintain and manage the switch Mini USB connector Mini USB connector pin number is shown in Figure 19 Figure 19 Mini USB Connector Mini USB connector pin definition is shown in Table 5 18 SICOM3010G User s Manual v1 0 Table 5 Mini USB Pin Definition VBUS USB connector pin number is shown In Figure 20 rem Figure 20 USB Connector USB connector USB pin definition is shown In Table 6 Table 6 USB Pin Definition 5 5 Power According to the power input requirements use a 5 08mm spacing terminal block to connect power cable Note The cross section area of power cable is required to be greater than 0 75mm 19 SICOM3010G User s Manual v1 0 and less than 2 5mm The grounding resistance reguirement lt
11. 1000Base T X RJ45 ports power 29 SICOM3010G User s Manual v1 0 es C Table 11 SICOM3010G Optional Accessories GSFP 1000BASET RJ45 GSFP 10 100 1000BASE T RJ45 IGSFP M SX LC 850 0 55 1000Base X port multi mode LC connector wavelength is 850nm transmission distance is 550m IGSFP S LX LC 1310 10 1000Base X port single mode LC connector wavelength is 1310nm transmission distance is 10Km IGSFP S LH LC 1310 40 1000Base X port single mode LC connector wavelength is 1310nm transmission distance is 40Km IGSFP S ZX LC 1550 60 1000Base X port single mode LC connector wavelength is 1550nm transmission distance is 60Km IGSFP S ZX LC 1550 80 1000Base X port single mode LC connector wavelength is 1550nm transmission distance is 80Km 30 SICOM3010G User s Manual v1 0 10 Basic Features and Specifications Power Requirements Power input 12DC 9 18VDC 24AC DCW 18 72VDC 18 50VAC Power terminal 5 pin 5 08mm spacing plug in terminal block Power consumption SICOM3010G 2GX GE 6GE 10W MAX SICOM3010G 2GX GE 2GX 6GE 11 3W MAX Physical Characteristics Housing Metal fanless Installation DIN Rail or panel mounting Dimensions WxHxD 88mmx135mmx137mm Weight 1 25Kg Environment Limits Operating Temperature 40 C 85 U Storage Temperature 40 C 85 C Ambient Relative Humidity 5 95 non condensing MTBF 345000h Warranty 5 years For more information about KYLAND pr
12. 8 AWG yellow green line is shown in Figure 23 21 SICOM3010G Users Manual v1 0 cy j m o H S ri Hot shrinkage 18 AWG l g sheath Dip soldering n Protection Yellow green line Figure 23 18 AWG Yellow Green Line Unit mm Note If SICOM3010G needs to perform a dielectric voltage withstand test in order to avoid test failure please disconnect the 18 AWG yellow green line to disable surge protection circuit that leads to leakage electricity Protection ground Chassis ground Disconnect 18 AWG yellow green line Figure 24 Disconnect 18 AWG Yellow Green Line Unit mm 5 7 Relay Contact The relay contact is used for alarm output When the switch works normally the normally open contact of the alarm relay is closed and the normally closed contact is open when the alarm occurs the normally open contact is open and the normally closed contact is closed The alarm is outputted through a 3 pin 5 08mm spacing terminal block as shown in 22 SICOM3010G User s Manual v1 0 Figure 25 RLI 3 2 1 Figure 25 3 Pin 5 08mm Spacing Plug In Terminal Blocks The electrical parameters of the relay Max Switch Voltage 250VAC 220VDC Max Switch Current 2A Max Switch Power 60W Note Pin 1 and pin 2 are normally open contacts pin 2 and pin 3 are normally closed contacts When the switch works normally the pin 1 and 2 are closed pin 2 and pin 3 are open when the alarm occurs the
13. FP EECa MOG UG radiata etait ead n cet tiddale Sensi atiyte evantivace 16 5 3 1000Base X 10 100 1000Base T X Combo Poft ccccccceeeeeeeeeeeeeeeeees 17 54 Console Mena 20 ista nu ik no To aa 18 DO POWO hpa ss ska da A o A 19 6 GrOUNdIN O ecr sn 20 Bal Relay GONA C neo a ixoreeuakcie eave seiste acetals est eee 22 Oe Bl i IB AJ e e ANON S ators Aaa Soest ire E E E E E 23 gt ESSEBUNO bosa cert newt fare ale eater iddiy al ded iret sa ine sonal cant oi canal ram ance ates 25 Gi Managemen ACCESS sciatica att neska saa a r r A 20 8 1 Connected through Console Port osoossoson sono nnr nn vn nrnn nn 25 8 2 Connected through Ethernet Cable sooooososvsonnnnvnn nr nvnnn rn 28 9 3 NVCDN CCOSS us pruzina konc Kap Ton o a r oo ance 28 9 Product Configuration Information oosooovnvvonn vn nnvnnn nn 29 10 Basic Features and Specifications ccccccceccccseeeceeeeeseeeeseeeeeseesessueeseueesseeesaes 31 SICOM3010G User s Manual v1 0 1 Packing List SICOM3010G Industrial Ethernet Switch 1 CD 1 Screwdriver 1 18 AWG yellow green line 1 Certificate of Quality including Certificate of Compliance 1 Note After unpacking please check the accessories and the appearance of the equipment If anything is missing or damaged please contact us 2 Product Overview SICOM3010G Is a series of green low power consumption and full Gigabit ports industrial Ethernet switch that can
14. SICOM3010G Industrial Ethernet Switch Hardware Installation Manual KYLAND Kyland Technology Co LTD Publication Date Oct 2011 Version V1 0 Customer Service Hotline 8610 88796676 FAX 8610 88796678 Website http www kyland cn E mail support kyland biz SICOM3010G User s Manual v1 0 SICOM3010G Industrial Ethernet Switch Hardware Installation Manual Disclaimer Kyland Technology Co Ltd tries to keep the content of this manual as accurate and as updated as possible his document is not guaranteed to be error free and we reserve the right to amend it without notice to users Copyright 2011 KYLAND Technology CO LTD All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation SICOM3010G User s Manual v1 0 Notice for Safety Operation This product performs reliably as long as it Is used according to the guidance Artificial damage or destruction of the equipment should be avoided Read this manual carefully and keep it for future reference Do not place the equipment near water sources or damp areas e Do not place anything on power cable or put the cable in unreachable places Do not tie or wrap the cable which may cause a fire risk Power connectors and other equipment connectors should be firmly interconnected and checked frequ
15. ently Do not repair the equipment by yourself unless it is clearly specified in the manual Please keep the equipment clean if necessary wipe the equipment with soft cotton cloth In the following cases please immediately shut down your power supply and contact your Kyland representative Water gets into the equipment Equipment damage or shell damage Equipment operation or performance has abnormally changed The equipment emits odor smoke or abnormal noise SICOM3010G User s Manual v1 0 Contents 1 SE AG GUNG Nel Sl Getihaieaates tte ra tee te creag teen tnantatetined tends E 4 2 IPVOOUCT OVCIVIGW sarine dole to Zoo dob Dada Dl iba 4 s Structure and ALE ACE uritit uku ta itn l hual deo ba l iva lol bu kk lot Tnno o 5 stb dronmi aha dn ada r teenage mana 5 3A TOD AINSI soren ET SRR 7 A WOU sessi EE EET E Meant dasiaannae Mean detensbatmetelnat acces 8 AS JUMEASION DRAWING sos on 8 1 2 MOUNINO SIEDS sisal n inie h lol sabes ceeds eawivel cua dusbeaaccasteps deeatanieiaacaheeaateaede 9 5 Gable COnne Gon sidicinsiuaiainohi ake nsiGendaiebactdniotudsiviusuiaiuiadnsatdamssdehdasstuaidensuiaiciastuss 12 9 1 10 100 1000Base T X Ethernet Port cc eecceeeeceeeeeeeeeeeeseeeeseeeseeeeseeees 12 5 2 1000Base X 10 100 1000Base T X SFP Port osoossoonnvn vvn vse 14 0 2 1 Gigabit SFP Optical Module z ss scoc lnk cisujobunot d blud okn Oil 14 52 2 Gigabit S
16. for SICOM3010G on the wall or in cabinet ensure that there is adequate space for the switch step 2 Drill 4 holes on the selected position according to the panel mounting dimension drawing use a cross screwdriver to screw 4 cross slot screws M3x10 into holes Don t tighten the screws completely leave about 5mm of space between Step 3 Aim 4 mounting holes on SICOM3010G mounting plate at 4 fixed screws pass the screws through 4 holes with the diameter of 6 5mm 96 5 10 SICOM3010G User s Manual v1 0 then slide down SICOM3010G as seen below finally screw 4 screws tightly Now the SICOM3010G should be firmly fixed to the wall or cabinet Figure 8 Panel Mounting Remove SICOM3010G from wall or cabinet The specific steps are as follows Step 1 Use a screwdriver to loosen 4 screws move the switch up to let screws into 4 holes with the diameter of 6 5mm 96 5 Step 2 Unscrew the screws from wall or cabinet remove the switch from wall or cabinet Figure 9 Dismounting 11 SICOM3010G User s Manual v1 0 5 Cable Connection 9 1 10 100 1000Base T X Ethernet Port 10 100 1000Base X Ethernet RJ45 port can be connected to terminal equipment and network devices with straight through cables or crossover cables RJ45 connectors must be equipped at both ends of cable e Pin definition of 10 100 1000Base T X RJ45 port Pin number of 10 100 1000Base T X RJ45 port is shown in Figure 10 o 70 43 2 1 Figure 1
17. k Connections Figure 26 Hyper Terminal 4 Build a new connection named aa New Connection Hyper Terminal Connection Description UA New Connection Erter a name and chonn an icon im the corneciior ad Basmou Figure 27 New Connection 9 Select COM port as the connection type 26 SICOM3010G User s Manual v1 0 aa HyperTerminal Enter detaili for the phone number that you want to dat Countey region Suna code Comet ng a Cancel Figure 28 Choose Port 6 Set the parameters of COM port Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None aa HyparTenminal CHILE Figure 29 Set COM Parameters 7 Click OK to enter the CLI interface and type in a CLI command from Table 9 Table 9 CLI Command User View SWITCH gt enable Enter management view Management View SWITCH show interface Show the IP address of current switch 27 SICOM3010G User s Manual v1 0 Management View SWITCH show version Show version of switch Management View SWITCH load default Restore default configuration except for IP address Management View SWITCH config terminal Enter configuration view 8 2 Connected through Ethernet Cable 1 Connect any RJ45 port of the switch with the Ethernet port of a personal computer with a RJ45 cable 2 Open Run window from the start menu then input telnet IP address
18. oducts please visit our website http www kyland cn 31
Download Pdf Manuals
Related Search
Related Contents
Manuel de l`opérateur Fourth Edition 取扱説明書 Robô Mapeador Bedienungsanleitung Human Touch 100-ZG20-005 User's Manual Condiciones generales de venta Muse M-051 R : Free Download, Borrow, and Streaming : Internet Archive KULT Stabmixer Sony VAIO VPCEA21FX AS 900 ENDURO + 915 ENDURO Copyright © All rights reserved.