1. Alarm over IP IRIS Touch Home Installation Manual Version 1 0 ENGLISH Now certified and compliant with EN50131 EN50136 Security Grade 4 ATS6 touch 1 Introduction No more bulky batteries just one sleek unit with 24 hours or more runtime after mains failure To meet the rapidly increasing demand for cost effective Alarm over IP AolP equipment for the SME and home markets Chiron has developed the IRIS Home unit based on its successful IRIS Touch 100 and Touch 200 ranges By using advanced software intelligence and power management the IRIS Touch units can offer 24 hours or more for Grade 2 3 alarm systems without the need for bulky batteries The unit can be powered from a mains supply or the battery of an alarm panel In the case of external mains power failure the alarm battery backup will not be used and internal IRIS Touch Home batteries take over The sleek unit offers all the benefits and features of other diallers in the IRIS Touch range including remote access for Upload Download The IRIS Touch Home can be supplied in three forms Home 00 Home 20 and Home 40 All come with a fit and forget solution There are three models in the IRIS Touch Home family for single path or dual path transmission Feature IRIS Touch IRIS Touch IRIS Touch Home 00 Home 20 Home 40 Stylish tamper proof enclosure v 4 v Easy to install and test with touch screen interface v 4 v 2 wire POTS dial capture interface to alarm pan
2. the front cover to the bottom of the back plate Fix in place with the two screws provided Pull down the slider to reveal the touch screen Apply power to the input of the IRIS Touch Home To confirm power is applied the indicator LED at the top of the IRIS Touch dialler is either steady or flashing IRIS Touch Home Series Installation Manual 9 of 17 5 Entering the Installers Menus On first power up the installer is prompted to select the language required From there the installer menus can be accessed _ tats Trouble Leta ers Fea Select Installers Menu The default installer code is 111111 Select OK It is recommended that this default is changed which can be done by selecting Settings and then scrolling to Installers Password 6 GPRS Network Scan It is strongly recommended that this scan is carried out to ensure there is sufficient network coverage from at least two wireless base stations to warrant a reliable connection Scan In Prosress Looking For Providers an In Progress Bese Stations Fourd Select Run Network Scan This scan must be carried out without the SIM card fitted Always remove power from the dialler before fitting or removing the SIM card The dialler listens for every base station in range requests operator name and records the signal strength This will take a few minutes It is recommended that for the chosen network SIM card used
3. Battery Status Then tick Recharge battery and the battery charge counter will be reset to 000 and a new charge will begin 9 Checking Status There are five states the IRIS Power Home can be operating in these are explained below Battery Status Battery off The Battery off state as shown under the Battery Status screen can indicate that the Power Pack is not enabled the batteries are not present or the battery deep discharge protection has been triggered Battery Normal The Battery Normal state indicates the IRIS Touch Home is healthy Battery Charging The Battery charging state indicates the batteries are being charged This can be initiated by enabling the Power Pack mode ticking Recharge Battery or a regular top up charge to maintain the batteries Battery Discharging The Battery discharging state indicates that the IRIS Touch Home is running from batteries This could be due to the input power being not present or the IRIS Touch Home detecting mains failure and or loading of the external power supply Battery Testing The Battery testing state indicates the IRIS Touch Home is testing the batteries health 14 of 17 IRIS Touch Home Series Installation Manual touch 10 Maintenance Recommendations The batteries should be routinely replaced every two years When the batteries are replaced the installer must tick the New Battery tick box found in the B
4. Monitoring Centre Make sure that the monitoring centre to which the IRIS Touch Home will send alarm signals is equipped with the appropriate IRIS receiving system The following information should be obtained from the monitoring centre e Dialler account number Monitoring centre IP address 3 2 GPRS SIM Card and Access Point Name If the installation uses GPRS then a SIM card will be required The IRIS Touch Home will also need to be given a GPRS Access Point Name APN This can be obtained from the SIM card provider 3 3 Batteries The IRIS Touch Home requires 8 x 1 5V NiMh AA size rechargeable batteries not included The required battery capacity is 2050mAH minimum and ideally they should feature low self discharge Batteries must be approved to IEC61951 2 EN61951 2 Recommended manufacturers types are GP ReCyko 210AAHCB e Annsman maxE 2100 Other battery types including non rechargeable batteries must not be used 3 4 Package contents IRIS Touch Home plastic housing fitted with the dialler PCB PSU PCB power and interconnect cables 3 x screws and plugs for fixing the housing to a flat surface Antenna Ethernet cable Stylist RJ11 cable Dial Port 18k ohms sense resistor 3 5 Ferrites If the installation is in a residential environment you will need to fit ferrite chokes to the Ethernet cable if used This is required to ensure compliance with EMC Class B emissions Suitable ferrites can b
5. and signal strength See Seb tee LEO YInstallers Meru 1 OV for inputs SIM card holder H Oh imi T POWER Inputs INPUT a T USB Power Ethernet 4of17 IRIS Touch Home Series Installation Manual Tris touch 2 Configuration options The IRIS range of alarm dialers allows alarm systems to move into fixed line Ethernet and or wireless networks GPRS without the need to upgrade or replace the alarm system In some smaller alarm panels however the battery backup within the panel is not sufficient to power both the panel and an IRIS Touch dialler for a continued period of operation once mains power is lost The IRIS Touch Home enhances the IRIS Touch range by providing both the power and battery backup supply in a single unit The IRIS Touch Home offers various power supply and battery charging options 2 1 Powering from an independent mains adapter Power is provided from a separate DC mains power adapter provided for use with the IRIS Touch Home This mode can be used where a mains power socket is available The mains adapter should be specified to deliver up to 1A at 9 28V DC or 7V 20V AC Please refer to Figure 1 2 2 Intelligent powering from an alarm panel AUX output This uses an auxiliary power output from the panel Such as that used to power a siren This is intelligently controlled by the IRIS Home with power only being taken when mains power to the alarm panel is available This avoids the alarm panel batter
6. there should be at least 2 base stations with signal strength CSQ of 10 or more Reposition the antenna or use a higher gain antenna if necessary 10 of 17 IRIS Touch Home Series Installation Manual 7 Installation Wizard The Installation wizard guides you through the set up process The wizard informs you of successful progress as you go along and in general select Continue to carry on If there is a problem you will be told what it is and not allowed to continue until it is solved Select Installation Wizard There are 4 powering modes for the IRIS Touch Home The setup is described below for each of these Mode 1 Powered from an independent mains adapter Tick Independent PSU and select back No other settings are required Mode 2 Powered from alarm panel auxiliary output The IRIS Touch Home is powered from the alarm panels auxiliary output tick Panel AUX supply and then select Continue Then select the appropriate option given below Sense Pin wired to Alarm Panels low voltage DC supply If the Sense input pin of the IRIS Touch Home is wired to extend low voltage DC supply tick Voltage DC followed by Continue Yoltase AC Simal normal al re The IRIS Touch Home will monitor the voltage at the sense input pin and when the voltage is below the Low threshold it will run off its own oe thr Ej internal batteries No power will be taken from the alarm pa
7. attery Status section within the Power Interface settings IRIS Touch Home Series Installation Manual 15 of 17 Tris touch Appendix A Specification Power Supply Supply voltage 9V to 28V DC DC terminal or 7V to 20V AC RMS AC terminal Typical current consumption with IRIS Touch dialler 200mA 12V DC attached not charging Charging rate low Peak current consumption with IRIS Touch dialler 500mA 12V DC attached and 56 hour charging Charging rate low Typical current consumption with IRIS Touch dialler 300mA 12V DC attached not charging Charging rate high Peak current consumption with IRIS Touch dialler 800mA 12V DC attached and 28 hour charging Charging rate high Weights IRIS Touch Home unit 0 9Kg without batteries Fully packaged batteries not 1 04Kg included Conformance The IRIS Touch Home complies with the following European Directives Mi 1999 5 EC Radio amp Telecoms Terminal Equipment Directive Mi 2006 95 EC Low Voltage Directive Mi 2004 108 EC Electromagnetic Compatibility Directive Safety Care should be taken when interconnecting telecommunications equipment that only like interfaces are interconnected to avoid safety hazards SELV SELV Safety Extra Low Voltage is defined as a secondary circuit which is so designed and protected that under normal and single fault conditions the voltage between any two accessible parts does not exceed a safe value 42 4V peak or GOV dc m
8. aximum The interfaces on the IRIS Touch Home have the following safety classifications Dial capture interface SELV suitable for connection to the TNV interface of single line telecommunications equipment such as telephones faxes etc Mi Power Interface SELV for connection to a DC or AC supply Mi Inputs SELV for connection to alarm output pin 16 of 17 IRIS Touch Home Series Installation Manual The future of security secured IP by security professionals for the professional security industry CHIRON SECURITY COMMUNICATIONS Telephone 41 43 508 08 66 Fax 41 43 508 08 75 sales chironsc ch www chironsc com CHIRON SECURITY COMMUNICATIONS AG WORLD TRADE CENTER OFFICE 70 LEUTSCHENBACHSTRASSE 95 8050 ZURICH SWITZERLAND The information contained is supplied without liability for any errors or omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and foregoing restriction on reproduction and use extend to all media in which the information may be embedded 2013 Chiron Security Communications AG
9. ch dialler screws are not required Ensure that the rear tamper spring is located within the tamper tube Connect relevant cables to the IRIS Touch PCB W Ribbon cable from PSU PCB to IRIS Touch PCB E Power connection from PSU PCB to IRIS Touch PCB W Ethernet cable cream Ethernet only W Dialler cable grey Mi GSM antenna GPRS only Note the final positioning of the antenna is determined by a successful network scan to be performed as part of the configuration of the IRIS Touch dialer Fit the SIM card GPRS only 8 of 17 IRIS Touch Home Series Installation Manual 10 11 12 13 14 touch Fit the SIM card GPRS only Fit the SIM card Plug in the external cables E Plug the dialler cable into the alarm panel dialler If the alarm panel has screw connections cut the connector off the cable and strip the cable using the 2 inner wires Polarity is not important in this instance H Plug the Ethernet cable into the local IP router or socket that has been allocated for the IP connection Plug in the sense resistors Fit the 18K sense resistor in parallel with the dialler output of the alarm panel at the alarm panel end of the cable Note This resistor enables the IRIS Touch dialler to detect cable faults and or tampers and must be fitted at the alarm panel end of the cable to function correctly Fit the front cover Slot the top of the front cover into the top of the back plate and click the bottom of
10. e obtained from Chiron 6 of 17 IRIS Touch Home Series Installation Manual touch 4 Installing the IRIS Touch Home Use the following procedure to install the IRIS Touch Home The procedure below describes that used for dual path operation Where single path is being used please step over the instructions for the path not being used Ethernet or GPRS Refer to Figures 5 and 6 for cabling and connections 1 Determine which powering mode to use see above Do not apply power to the dialler until indicated 2 Decide where to run the cables Decide the best way to run the cables that will be required Panel dialler interface cable Ethernet cable and or GSM Antenna This can be either W Behind the unit through the wall Through the bottom of the back plate of the unit via the knock outs 3 Disassemble the IRIS Touch Home Remove the two case fixing screws and open the unit and remove the IRIS Touch dialler PCB Note The IRIS Touch PCB is retained by two clips located at the bottom of IRIS Touch PCB 4 Mount the housing on the wall Position the IRIS Touch Home housing on the wall Drill three holes put the cables through the opening at the base of the plate or via the knockouts and secure the plate to the wall with the three screws supplied 5 Fit the batteries Fit the eight batteries taking care that the orientation is correct This is shown in Figure 5 IRIS Touch Home Series Installation Manual 7
11. el v V v SIA 1 3 CID Scancom and Robofon protocols a v v Secure polling and alarm transmission over IP a 4 v Dual path v Security grade compliance Grade 2 Grade 2 Grade 2 USB port for local configuration v v 4 Pin inputs for alarm messages over IP 2 2 2 Pin inputs for alarm messages over SMS v v v Configuration and diagnostics over IP 4 4 v Smart identification of panel power loss v v v Advanced software control of power consumption Me y v 4 Powering options From alarm auxiliary output a v Y From alarm panel supply A v 4 From alarm battery 4 v v V v V From mains adapter 2of17 IRIS Touch Home Series Installation Manual touch Feature IRIS Touch IRIS Touch IRIS Touch Home 00 Home 20 Home 40 Battery run time after mains power failure Ethernet only polling 15 minutes or longer 24 hours 18 hours GPRS only polling 15 minutes or longer 24 hours 18 hours Dual path polling 15 minutes or longer 18 hours Battery recharge from discharge 56 hours 56 hours 56 hours Off the shelf NiMH AA size rechargeable batteries v a v Low battery alerts to monitoring centres 4 4 v IRIS Touch Home Series Installation Manual 3 of 17 Figure 2 LRA RES alr Ee ee ee UPUT Woah PAE ADAP TEA oO Waa ER FB Gave OF Par ore L WaT Bar Figure 3 Figure 4 bia Piman aA Tra EAL ORT ANAC Or Figure 5 Figure 6 Alarm dialler off hook Polling to monitoring Antenna centre icone Roaming SIM card Welcome to the EE oe
12. en from the alarm panel until the voltage goes above the High threshold The threshold High and Low can be altered by selecting Edit Mode 4 Powered from alarm panel battery If the IRIS Touch Home unit is powered from the alarm panel s battery tick Panel Battery and select Continue Pena are The IRIS Touch Home will measure its input voltage and when the voltage Fri praja is below the Low threshold the IRIS Touch Home will run on its own internal batteries No power will be taken from the alarm panel battery until the voltage goes above the High threshold The threshold High and Low can be altered by selecting Edit if required Select the network connection s to be used For dual path select both Monitor Dial Port should always be selected This requires the 18K ohm resistor provided to be connected at the alarm panel end of the dial capture cable If the alarm panel is not partitioned with multiple account numbers Alarm Override is selected as this means no changes are required to the settings within the alarm panel If you are using a SIM card that can roam between networks Roaming SIM is being used select it here to give increased reliability of communications Panel Shared FSU Pare Battery Exit Parel Battery Liar ation tertaces a Select in Monitor Dial Port Alarm Override Rosmima SIM Selec
13. ing test alarms from the alarm panel Exit must still be carried out GSM Sisal Strensth If connection via GPRS is selected the dialler will display the signal eee strength The dialler checks that there is registration with the GPRS network resistration GSH resistered GPRS Settings All GPRS networks require the Access Point Name APN to be set A few ne also require User Name USR and Password PWD Select Change to configure Select the item to be changed GPRS test roll The IRIS Touch will make a test poll and test alarm transmission over Successful GPRS Exit Note the normal sequence of sending test alarms from the alarm panel must still be carried out Do wou want to wee Fin alarme The dialler has inputs that can be used to send alarms or text messages independent to the alarm panel Select Yes if required Setup of the dialler is completed successfully You are now ready to test normal alarm transmission from the alarm Setur Completed panel to the monitoring station and verify these are successfully received by the monitoring station CFRE y amp IRIS Touch Home Series Installation Manual 13 of 17 8 Changing Batteries Fouer Interface Fa Batters Status Status Charsek When new batteries are installed the IRIS Touch Home should be instructed to carry out a full charge of the batteries Go to Settings and select the Power Interface menu then select
14. nel until the CEEE voltage goes above the High threshold The threshold High and Low can be altered by selecting Edit Farel Aux FaU Tenani a pe Sense Pin wired to Alarm Panels low voltage AC supply Woltase Al p _ _ Continue Sisal aes If the Sense input pin of the IRIS Touch Home is wired to the panel s low voltage AC power supply of the alarm panel tick Voltage AC The IRIS Touch Home then detects if AC is being supplied to the panel and determines whether to run from its internal battery are Soltas OC Sense Pin wired to Alarm Panels EPS failure output Yoltase AC inwe If the Sense input pin of the IRIS Touch Home is wired to an output of the alarm panel that indicates EPS failure tick Signal normal When the output is a positive voltage the IRIS Touch Home will be powered from the panel and when the voltage is low the IRIS Touch Home will run from batteries Should you need to invert the operation signal tick Signal inverse IRIS Touch Home Series Installation Manual 11 of 17 Mode 3 Powered from shared panel mains adapter If the IRIS Touch Home unit is powered from the alarm panels low voltage AC or DC supply tick Panel Shared PSU and select Continue The IRIS Touch Home will measure its input voltage and when the voltage is below the Low threshold the IRIS Touch Home will run of its own internal batteries No power will be tak
15. of 17 10 touch Plug in the connectors Please refer to Figure 6 Do not connect the power source or apply power until later Mode 1 Use a DC mains power adapter and wire to the DC input of the IRIS Touch Power Home PSU PCB board Mode 2 Wire the panel auxiliary output to the DC input of the IRIS Touch Home charger board Fit a separate cable from the Sense input of the charger board to either the alarm panel input from its own mains adapter or from a configurable output from the alarm panel that will signal AC fail Please observe that the Sense input is only suitable for low voltage DC max 28V or AC max 20V Mode 3 DC or AC Wire the output of the panel mains adapter 500mA at 9 28V DC or 7V 20V AC to the DC or AC as appropriate input of the IRIS Touch Home PSU PCB board Mode 4 Wire the output of the panel battery charger to the DC input of the IRIS Touch Home charger board Fit the tamper switch springs The IRIS Touch Home is protected against tampering e g removal from the wall or opening of the case by two tamper switches on either side of the dialler PCB These switches are held by springs that press against the wall and the top cover Before fitting the unit make sure the springs are fitted correctly to the tamper switches Fit the PCB to the back plate Fit the PCB to the back plate by sliding under the hooks at the top and pushing into the catches at the bottom Unlike the standard IRIS Tou
16. t Set and enter the account name allocated by the monitoring cente Select Save when done ARC IP Address If Alarm Override has not been selected then the phone number set in Set ARC IF address the alarm panel for the monitoring centre must be changed to the IP address of the monitoring centre This must be in 12 digit format in this case 10 1 2 36 becomes 010001002036 Select Save when done If connection via Ethernet is selected the dialler checks it is connected Select Continue In most situations the dialler will receive its own IP address automatically DHCP from the local router 12 of 17 IRIS Touch Home Series Installation Manual Select Fixed if the dialler is to be given a fixed IP address If a fixed IP address is required tick Fixed and then in turn click on IP Address Subnet Mask and Gateway All three must be configured These can be obtained from the local IT department The IRIS Touch will then check the IP address is a valid format The IRIS Touch will also check with Chiron s global reflash server to see if a new version is available If so we would recommend upgrading Each dialler regularly sends a poll to the monitoring centre to check the connection This confirms that polls can get through Successful Ethernet test alarm A test alarm is sent from the dialler as well Successful Note the normal sequence of send
17. y life being shortened during mains power failure This mode can be used where the alarm panel has an auxiliary DC power output of 9V to 35V DC that can deliver at least 500mA above the requirements of any other attached device Please refer to Figure 2 2 3 Intelligent powering from the panel mains adapter Power is provided via the low voltage AC or DC adapter used by the alarm panel Because the IRIS Touch Home senses the output voltage level of the alarm panel mains adapter it draws no current while the panel power supply is fully loaded In this mode the power input to the alarm panel must be accessible and has a connector for an additional cable This mode can be used where 500mA more than that required by the panel itself can be delivered by the adapter Please refer to Figure 3 2 4 Intelligent powering from the alarm panel battery charger Power will only be taken when mains power to the alarm panel is available preventing alarm panel battery life being shortened during mains power failure This mode can be used where the alarm panel uses a 12V battery the charger can deliver more than 500mA leaves its battery on charge at all times and does not have its own intelligent battery charging mode Please consult the alarm panel supplier if in doubt This method will affect the recharge time of the alarm panel battery Please refer to Figure 4 IRIS Touch Home Series Installation Manual 5 of 17 Tris touch 3 Before you start 3 1
Download Pdf Manuals
Related Search
Related Contents
Telefon Téléphone Telefono STR-DN1040 - Sony Europe PKZIP 6.0 for the X Window System Getting Started Oxygen Detector O 025 User Manual GE W25C Installation Guide JVC KS-F350R Cassette Player User Manual Whitehaus Collection WHKSDCR3-8101-ACO Installation Guide TWR-KL25Z48M User Manual - Freescale Semiconductor InFocus IN8601 Datasheet (French) Copyright © All rights reserved.