SMILE Condensation Water Pump Installation Manual
Contents
1. SMILE Condensation Water Pump nstallation Manual Application SMILE condensate pump is designed to automatically remove the liquid from air conditioners and evaporator coils The pump is made from a tough ABS plastic body so it will resist corrosion and impact and it is very silent 1 Features and technical specifications Model SMILE Electric specifications 230V 50Hz Length of supply cable about 800mm Energy consumption 22W Weight 1 5 kg Dimensions cm 180 x 150 x 105 Equipped with overflow safety switch Several international patents Precision water level control 2 Pump installation picture 1 Carefully unpack the pump and check for damage Make sure that all the required parts are included holder with screws The pump must be mounted level Install the pump near the air conditioning unit see picture 1 The air conditioner drainage tube must be inserted inside the hole situated on top of the pump and at the distances mentioned on picture 1 Do not install the pump near a heat source We suggest not to place the pump above electrical equipment and valuables W Installation of the drainage tube Follow the measurements of the tube mentioned on picture 2 max 2 meters vertically and max 10 meters horizontally Use a PVC drainage tube of 4x6 and insert it for more than 1 cm into the rubber outlet hose of the pump see picture 3 The drainage tube must keep straight see picture 4 4 Wiring conn
2. ection Shut off electrical power at the fuse before making any wiring connections The pump must be connected to a constant line voltage source and not to a fan or other device that may run intermittently The pump is equipped with an overflow alarm circuit to prevent condensate water from overflowing The contact is normally closed 250V 5A and can be used to switch the air conditioner off or to activate a visual or sonorous alarm 6 Precaution In the event of power failure please remove the air conditioner drainage tube away from the water pump Redirect the drainage pipe to an external bucket to collect the remaining condensate water 7 Parts of the pump see picture 5 Front side Inlet air conditioner s tube Outlet drainage tube AC Power cable Overflow alarm circuit cables Back side Holder must be mounted 8 Troubleshooting In case of malfunction of overflow Make sure that the AC power is OK Check if the drainage tube is blocked or not Make sure that the air conditioner s pipe is inserted properly
Download Pdf Manuals
Related Search
Related Contents
Cabletron Systems SWPIM-BRI User's Manual MiniDSP User Manual User Manual Samsung WB210 Felhasználói kézikönyv Triple Speaking Modes User Manual User Manual Profibus Master Profibus Master Module Samsung Aspirador sin IMC Networks iMcV-DS3/E3-LineTerm Copyright © All rights reserved.
Failed to retrieve file