Aperio Online Mechanical Installation Manual
Contents
1. 4 Back amp Close Cancel 5 Hold the credential at the lock to update the time The time of the lock will now be automatically set each time you configure and update the device 6 Click Close to exit the device update configuration Device update result The result ofthe device update will be presented below successfully updated time and date 52 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Importing and exporting configurations General The stored configurations made in the configuration wizard can be exported to a file so that more than one Aperio Programming Application can share the same configuration information When you import an exported configuration you add it to the local configuration storage and then you can apply that configuration to a lock sensor or communication hub i When you export a configuration you cannot change the name of the configuration only the file name holding the configuration information Since configurations can be shared between different Aperio Programming Applications it is preferable that a shared configura tion identified by its unique name also has the same meaning on all Aperio Programming Applications It is therefore advisable that you choose the name of the configuration wisely when you store the configuration Exporting Configuration 1 On the File menu select Export Import
2. gt Browse my computer for driver software Locate and install driver software manually Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 11 Aperio Online 5 Browse for the new driver and click Next Browse for driver software on your computer Search for driver software in this location Include subfolders gt Let me pick from a list of device drivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device 6 Depending on the windows system history regarding driver installations you may have to confirm driver installation If so select Install this driver software anyway Windows can t verify the publisher of this driver software Don t install this driver software You should check your manufacturer s website for updated driver software for your device Install this driver software anyway Only install driwer software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information v See details T2 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 7 The first driver is now installed C l Update Driver Software Tritech TriBee USB Windows has successfully updated your driver software Windows has finished installing
3. 12345676 Description Janitor Card Type MIFARE Classic or MIFARE Plus UID Card number Description For example the credential owner MIFARE Sector Enter new override credential Enter sector data for the credential You may also enter a description ofthe credential Card Type Card Type MIFARE Classic Sector data The sector data is entered in hex format For example SAAbBeCCDD O0112235 Description Janitor Card Type MIFARE Classic or MIFARE Plus Sector data Sector data stored on the credential This value is normally stored in the EAC Description For example the credential owner Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online MIFARE Sector and UID Enter new override credential Enter UID and sector data for the credential You may also enter a description of the credential Card Type Card Type MIFARE Classic x UID The UID is entered using hexadecimal format For example 25A78FA4 11223344 Sector data The sector data is entered in hex format For example SSAABBCCDD 123454BCDE Description Janitor Card Type MIFARE Classic or MIFARE Plus UID Card number Sector data Sector data stored on the credential This value is normally stored in the EAC Description For example the credential owner ISO
4. Database According to FCC15 105 b Information to the user This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet ona circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 3 pass mutual authentication challenge response protocol based on AES128 Standard Aperio authentication scheme The communication is encrypted by a unique session key Secret information such as encryption keys is never visible outside the protected flash of the microcontroller Unique encryption key seed
5. 2 6 18976 No sanity check is done by the Programming Application before the firmware download starts Applying an older firmware than installed can cause the hardware to malfunction 9 All firmware is selected to be downloaded by default Uncheck firmware that you do not wish to download Firmware Lock Main Application Lock Main Application 6 1 19489 Firmware Version 6 1 19489 Lock UHF Progress Information 2 3 18976 Not started Lock Secure Area 5 bo on 2 6 18976 10 Click Start to initiate the upgrade process Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 57 Aperio Online 11 If you are upgrading a lock sensor you will be prompted to hold a credential at the lock engage sensor before the download starts Waiting for user to Show card Engage sensor Show card Engage sensor Time remaining until timeout 14 seconds Result The upgrade will start with the first selected firmware in the list A green arrow to the left of the selected firmware will indicate the firmware is being upgraded and the firmware is downloaded ey x Firmware Lock Main Application Lock Main Application A 4 J 6 1 19489 Firmware Version 6 1 19489 Lock UHF Progress Information 2 3 18976 Loading firmware Lock Secure Area 4 y 2 6 18976 Close After finished downloa
6. Assigned Address 0x115e EAC Address 1 Radio protocol version 23 Device Status Lock sensor USB Radio COM 10 May 14 2013 12 50 23 PM 2 Hold the credential at the lock or engage the magnet for the sensor Show card Engage sensor Time remaining until timeout 12 seconds LL 3 Aprogress bar shows that the transfer is being performed 4 Ifthe encryption key is successfully loaded you get a message that states Successfully updated security mode Click OK Successfully updated security mode Result Check the lock symbol at the right side of the door to see that the door has been set to Customer mode Manufacturer mode Communication Hub EAC Address UHF ah 124521 a 014860 024521 WM co E Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 47 Aperio Online 48 Changing the radio channels Changing the radio channels can be necessary if you experience interference between communication hubs which can occur if many hubs are installed close to each other i To use this function you must have the Show advanced settings checkbox checked in User Settings see section User settings on page 6 Follow these steps to change the radio channel for the communication hub and lock sensor i Always change the radio channel in the locks sensors before changing in the communica tion hub 1 Select the lock sensor in the scan res
7. May 14 2013 5 02 11 PM Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 4 Programming Application Functions Opening creating installations An installation is a password protected set of settings you need when you want to communicate with a hub and or a lock An installation is linked to an encryption file that is needed in order for the communication to work 1 Select File New or Open File Scan Settings Help New Ctrl N Open Ctri 0 Export Import Configurations Exit Ctri F4 Scanning and adding communication hubs 1 After opening an installation the scanning process starts automatically To manually scan for communication hubs select Scan Quick Scan Quick scan F7 Scannin Scan Ctri F Please wait Refresh F5 Result All communication hubs within reach of the USB Radio device of your computer are displayed in the scan result table Select the Communication Hub to retrieve detailed information from Check the boxes for each Communication Hub and press Show details to retrieve detailed information To select all click in the checkbox in the title row or press Ctrl A or Ctrl Communication Hub Radio channels UHF Link 29E6 12 16 24 1C3D 15 20 2451 13 18 23 16F1 14 19 25 0D36 11 16 25 92FC 11 16 25 298 11 16 26 2A2D liz 25 29F5 lis 20 2080 lis 20 9367 13 23
8. Password eeeseses a Get 54 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online The configuration is identified by its name not the name of the export file When importing a configuration that already exists in the Programming Application you will be prompted if you want to replace the existing configuration Configuration already exist in storage Would you like to overwrite the existing configuration Deleting configuration In the Export Import Configurations view you can also delete existing configurations Right click the configuration and select Delete SE Export Import Configurations Available configurations Configural Standard lock aasian Ad ding o Security Custom Time and Ciirrert Upgrade of communication hub lock sensor firmware This chapter describes how to upgrade communication hubs and locks sensors with a new firmware The upgrade procedure will be executed only for the selected communication hub or lock sensor depending on the content of the firmware The firmware file only contains firmware applicable to either a communication hub or a lock sensor Always upgrade the communication hub before upgrading the locks sensors The reason is that hub should always support older lock sensor firmware but the opposite may not always be possible When upgrading AH30 communication hubs to the latest firmware when using the DIP s
9. Show card Engage sensor Time remaining until timeout 2 seconds 3 When the lock has stopped blinking you can click Done to see the pairing result Result The result is displayed Pairing result The result of the pairing requestis presented below Communication hub paired successfully to 0148ED Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 11 Aperio Online 12 Configure function Wizard Open the configure function by right clicking a communication hub or lock sensor and selecting Configure SA Aperio Progra g Ap File Scan Settings Help Lock sensor Communication Hub EAC Address 02452 Configure 02452 02452 013542 0148E8 0148ED Lock sensor 011043 b Communication Hub 0216F1 gt gt Upgrade Firmware Depending on the hardware different windows will appear in the wizard Security mode radio channels and status message interval will be applied only to the lock sensor or the communication hub depending on which hardware menu that was selected on the right click menu The following sections describe each window in the wizard RFID configuration Lock sensor A corresponding firmware for the given RFID type must be installed on the locks sensors Click Add Change to enter the settings for each credential type RFID Configuration Note that current RFID configurations in the Aperio lock are not displaye
10. 2 22 Low power June 17 2013 2 21 54 PM Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 41 Aperio Online 2 Hold the credential at the lock or engage the magnet for the sensor Show card Engage sensor Time remaining until timeout 11 seconds 3 Inthe event log window click Save As to save the information to a txt file or click Close to exit without Saving Event log for Lock sensor 0148E8 Created May 14 2013 11 50 34 AM CEST Number Date January January January January January January January January January January January January January January January January January January January January January January Power On Reset O0x9c02 New battery detected 0x00le Flash content errors in NVM seg Power On Self Test POST perfo Power On Reset O0x9c02 g New battery detected 0x001f Power On Self Test POST perfo Power On Reset O0x9c02 New battery detected 0x001f Power On Self Test POST perfo Power On Reset O0x9c02 New battery detected 0x0020 Power On Self Test POST perfo Power On Reset 0x9c02 New battery detected 0x001f Power On Self Test POST perfo Power On Reset O0x9c02 New battery detected 0x001f Power On Self Test POST perfo Soft reset New Main Application Firmware p System reset 0x8f02 January Debug event FATAL 513 January System reset 0x8f02 March 22
11. 2007 Las The RTC is about to be updated ansin ll TI mm ama D oJ BUN e Sayre wh ay ee he O en ee en ee The window contains information of system events including consecutive number date and what type of system event that was performed If the number of events exceeds 200 older events are overwritten 42 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Get Audit Trail This function displays a complete list of all access attempts for a particular lock not available for sensor 1 Right click and select Lock sensor Get Audit Trail a Lock sensor 0216F1 74571 Communication Hub Lock sensor 013542 Communication Hub 024521 Upgrade Firmware USB Radio COM 10 1 00 8 a SS Apply configuration Configure Retrieve system information Get Event Log Communication Hub 024521 MAC Address al Location are Flavor are Version ader Version Get Audit Trail protocol version lel Change radio channels Switch to Manufacturer Mode Change physical location name Unpair lock sensor from communication hub channels D ddressing mode vitch value ddress Remote open is activated Number of paired locks and sensors Device Status Lock sensor 013542 MAC Address Assigned Address EAC Address Radio protocol version 2 Hold the
12. Assigned Address 0x1230 EAC Address 1 Radio protocol version 22 m USB Radio COM 10 May 14 2013 11 48 02 AM 2 Enter a description that clearly identifies the lock position and click OK Edit Physical Location in Lock sensor 0148E8 The maximum number of characters describing the physical location is 21 Physical Location Floor 1 Door A14 3 Foracommunication hub the information is updated immediately If you change the physical location name for a lock sensor you will be prompted to hold the credential at the lock or engage the magnet for the sensor Show card Engage sensor Time remaining until timeout 15 seconds Result After successful reading a progress bar shows the download After update the new location name can be found in the Lock sensor section on the lower right side of the installation view Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online fee ile Scan Settings Help Lock sensor Communication Hub EAC Address UHF Link Im Communication Hub 024521 MAC Address 00 17 7 4 01 02 02 45 21 Physical Location Office A RS485 Multiple Lock Aper Firmware Version 6 0 22795 Firmware Flavor Bootloader Version 1 2 5 Radio protocol version 23 Channel 25 2 475 GHz Radio channels 11 16 25 PAN ID 4521 EAC addressing mode Legacy address offset DIP switch value 1 EAC Address DIP Sw
13. 00 17 7a 01 02 02 45 21 Oxa55a Created May 14 2013 12 48 20 PM CEST Customer Mode Time since last system reset 14 days 18 hours 35 minutes and 46 seconds Production Date Main board January 10 2011 11 05 50 AM UTC Device Information Type Aperio Hub Serial number 0 Version Information Firmware Flavor R5465 Multiple Lock Aperio protocol Major version 6 Minor version 0 Build number 22795 A Code 0 Version Information Hardware Reset diagnostic counters Change EAC address CON Ani s espero Frogr Result The Programming Application connects to the unit Eile Scan Settings Help m Lock sensor Communication Hub EAC Address UHF Link Communication Hub 024521 O216F1 Unknown MAC Address Lock sensor 0148ED Physical Location Communication Hub 024521 gt Apply configuration are Flavor Configure versi Upgrade Firmware etikkin are Version Pair with lock or sensor ader Version por Retrieve systern information eae el Change radio channels channels Change EAC Address gt Change physical location name Hdressing mode Switch to Manufacturer Mode fitch value EAC Address Number of paired locks and sensors Device Status Lock sensor 0148ED MAC Address Assigned Address EAC Address Radio protocol version Device Status 00 17 7a 01 Office A RS485 Mul 6 0 22795 1 2 5 23 11 2 405 G 11 16 2
14. 2013 Aperio Online Setting the time of a lock Follow these steps to set the time of a lock 1 Select a lock in the installation view 2 Onthe menu bar select Views Installation Configuration and check that the Update device time during door configuration checkbox is checked MIFARE UID format Select how the MIFARE UID shall be Formatted in Audit Trails and when configuring Override Credentials Decimal Format i e 631738276 Hexadecimal format reverse byte order i e 448F4725 Decimal Format reverse byte order i e 2760877861 Configuration wizard settings Update device time during door configuration lt a 3 Close the Installation Configuration view Right click and select Lock sensor Configure Click Next repeatedly until you reach the Device Update window Device Update The settings are now ready to be transmitted to Lock sensor You might need to Show card Engage sensor to Lock sensor Click Next The Following updates will be transmitted to the Aperio Lock sensor Time and date Current system time Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 5i Aperio Online 4 Click Next Device update result The result of the device update will be presented below Waiting for user to Show card Engage sensor Show card Engage sensor Time remaining until timeout 11 seconds i OIS
15. Configurations TA Export Import Configurations Ea Available configurations Configuration Content Standard lock configuration Adding one override credentials Admin MIFARE Classic 25a78fa4 Security mode Customer Mode Time and date Current system time Import Export 2 Select the configuration that should be exported to file and click Export 3 Select the folder where you want to store the configuration select a filename and click Save Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 53 Aperio Online 4 Choose a password that will be used when importing the particular configuration confirm it and click OK Password Enter a password that will be used to save the configuration securely Password eeeccccces Confirm password secccecece i Configuration successfully exported to file Note that the password must contain at least 8 characters Importing Configuration Importing a configuration takes a previously exported configuration and adds it to the local configuration storage 1 Onthe Views menu select Export Import Configurations View and click Import Available configurations Configuration Content SS Standard lock configuration 2 Selecta valid configuration XML file and click Open 3 Enter the password and click OK Password Enter the password for the confiquration
16. Document No ST 001321 A Date 8 juli 2013 69 Aperio Online 70 Updating the USB Radio driver To update an existing Tritech TriBee USB Driver you need to manually update both the TriTech TriBee USB bus driver and the Tritech TriBee USB port driver If you have an older driver that works fine you do not need to upgrade but if you experience problems with the driver or if you are running the Aperio Programming Application on Windows 7 or Vista you are encouraged to ensure that you are using the latest driver Check current driver version Do the following Windows 7 or Vista Open the Device Manager Double click on TriBee USB Serial Port COMx under Ports COM amp LPT Windows XP Open the Computer Management Control Panel Double click on the Tritech TriBee USB Serial Bus driver under Universal Serial Bus controllers i It is important not to let Windows find the driver automatically since it will fail and install the wrong version Update in Windows 7 or Vista 1 Check that the USB Radio Dongle is connected and open the Device manager 2 The following hardware is to be updated Ports COM amp LPT TriBee USB Serial Port COMx Universal Serial Bus controllers Tritech TriBee USB File Action View Help 9 55 G B mee RG 41 Ports COM amp LPT ol ECP skrivarport LPT1 i I TriBee USB Serial Port COM10 gt 2 Processors PP Security Devices gt Q Sound video and game controllers
17. Processors Scan for hardware changes ADD Security De Properties Tritech TriBee USB Driver Provider Tritech Driver Date 2009 10 22 Driver Version 2 6 0 0 Digital Signer Not digitally signed Driver Details To view details about the driver files To update the driver software for this device If the device fails after updating the driver roll ahaa back to the previously installed driver Disables the selected device To uninstall the driver Advanced Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 6 Inthe Update Driver Software dialog click on Browse my computer for driver software How do you want to search for driver software gt Search automatically for updated driver software Windows will search your computer and the Internet for the latest driver software for your device unless you ve disabled this feature in your device installation settings Browse my computer for driver software Locate and install driver software manually 7 Ifthe Aperio Programming Application has been installed a typical path to the driver folder is C Program Files Assa Abloy Aperio Programming Application Tritech TriBee USB Driver Click Browse to locate the driver folder Then click Next Browse for driver software on your computer Search for driver software in this location Abloy Aperio Programming Application Tritech TriBee US
18. for each installation The encrypted database in Programming Application is password protected The computer must also be physically protected AES and RNG tested according to NIST National Institute of Standards and Applicable tests Technology test vectors http csrc nist gov groups STM cavp documents rng RNGVS pdf http csrc nist gov publications fips fips 197 fips 197 pdf Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience assaabloy com aperio Contact Sweden Finland Wireless a lock apPErIO technology N ASSA ABLOY AB Box 70340 107 23 Stockholm Visiting adress Klarabergsviadukten 90 Phone 46 8 506 485 00 ABLOY OY Wahlforssinkatu 20 80100 JOENSUU Phone 358 20 599 2501
19. gt lt Storage controllers gt lll System devices a Universal Serial Bus controllers y Intel R ICHS Family USB Universal Host Controller 2 y Intel R ICH8 Family USB Universal Host Controller y Intel R ICH8 Family USB Universal Host Controller y Intel R ICH8 Family USB Universal Host Controller F Intel R ICH8 Family USB Universal Host Controller y Intel R ICH8 Farnily USB2 Enhanced Host Controller 2836 y Intel R ICH8 Farnily USB2 Enhanced Host Controller 2834 L Tritech TriBee USB USB Mass Storage Device USB Root Hub Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 3 Double click the TriBee USB Serial Port COMx driver under Ports COM amp LPT Enter the Driver tab click Update driver TriBee USB Serial Port COM16 Tritech 2009 10 22 2 0 0 0 Not digitally signed To view details about the driver files To update the driver software for this device F the device fails after updating the driver roll back to the previously installed driver Disables the selected device To uninstall the driver Advanced How do you want to search for driver software gt Search automatically for updated driver software Windows will search your computer and the Internet for the latest driver software for your device unless you ve disabled this feature in your device installation settings
20. hub requires that DIP switch 1 is set to position ON Tip You do not have to enter the override credential data manually for every door to be configured This can be saved using the Save configuration function as the last step of the configuration wizard 1 To add an override credential select the desired card type in the drop down list and click Add Override Credential Add and replace override credentials If no changes are made the credentials in the lock will be left unchanged Note thatthe list below does not show credentials currently loaded into the lock If you load new cards into the lock the old cards are replaced Click Next to continue MIFARE UID Classic Plus MIFARE Sector Classic Plus Description MIFARE Sector and UID Classic Plus HID Prox and EM Prox PIN Seos Legic UID Legic Data F Remove all credentials in lock See the list below for a description of each credential i If you check Remove all credentials in the lock all existing override credentials in the lock will be deleted during the configuration process Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 25 Aperio Online MIFARE UID Enter new override credential Enter VID for the credential You may also enter a description of the credential Card Type Card Type MIFARE Classic w UID The UID is entered using hexadecimal format For example 25A 8FA4
21. is the default value notthe one currently in the lock The control interval can be in minutes or hours depending on the type of lock Control interval 60 The battery power alarm is sent from the lock to the EAC system and is used to indicate when it is time to replace the battery It may be necessary to configure the alarm triggering depending on the type of battery used and the surrounding temperature e g in cold surroundings the battery runs out faster This only applies to products with lithium batteries that are using energy counter For prod ucts with battery measurement on the secure side P100 I100 currently the interval you set translates into hours i e 6 minutes 6 hours on those products Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Status Report Interval Status Report Interval The value below is the default value notthe one currently in the Lockfsensor Message Interval minutes 60 The interval setting is normally set to 60 minutes If Remote Open functionality is used this parameter should be set to a shorter interval such somewhere in between 5 and 15 minutes O Lowering the status interval time for any reason will have an adverse effect on the battery life of the product As the status message interval is used by the communication hub to detect if the lock has gone offline any changes to this interval must be done on both
22. locks have support for other mechanisms such as buzzers Sensor ae Configure Sensor Events 1 hours and 0 minutes This setting applies for locks with built in sensor By activating this function the lock sensor will stop sending passage events to the EAC for unlock durations longer than you set here This setting will save battery life in high traffic doors Device update page Saving Configuration lt B Configure Lock sensor 013542 Here asummary of configurations that will be transferred to the unit The Device Update dialog box shows a summary of the configuration tasks that will be downloaded to communication hub lock sensor The configuration may be used later to configure other devices with the same information by clicking Save configuration Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 1 The Save Configuration dialog box shows a summary of the configuration tasks that have been collected during the different steps in the Configuration Wizard You can exclude some tasks by simply ticking the check box 2 Recommended tasks to save could be RFID configuration Change security mode Override credential Device time update And optionally some advanced features like Battery Alarm Status configuration and Locking parameters If you choose to save a configuration keep in mind that some configuration settings should
23. normal operation the security mode should not be altered However if the hardware must be sent to the factory for service or repair purposes the security mode must be set to manufacturer mode before service Explanation of symbols Customer mode Door is using secure radio Communication with the customer encryption key Manufacturer mode Door is using insecure radio communication with the default encryption key amp Conflicting mode The modes in the lock sensor and the communication hub are not the same Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 1 Right click the lock sensor and select Switch to Customer Mode Switch to Manufacturer mode File Scan Settings Help Lock sensor Communication Hub EAC Address UHF Link Communication Hub 0216F1 Apply configuration MAC Address 00 17 74 01 02 Configure Firmware Flavor RS485 Aperio P 6 0 22795 1 2 5 Get Event Log 23 Upgrade Firmware Get Audit Trail 19 2 445 GHz 14 19 25 16F1 Switch to Manufacturer Mode Hormal addre Lock sensor 011043 Retrieve system information Communication Hub 0216F1 j Change radio channels Change physical location name Unpair lock sensor from communication hub DIP Switch Number of paired locks and sensors 4 Device Status EAC offline Lock sensor 011043 MAC Address 00 17 74 01 02
24. the driver software for this device Tritech TriBee USB 8 Click Close and go back to the Device Manager Now double click the Tritech TriBee USB driver under Universal Bus controllers 9 Install the second driver by repeating from step 3 When done the same message as above Windows has now updated driver software is displayed 10 Reboot Windows and open the properties dialog in the Device Manage again for the two Trilech TriBee USB drivers and verify that they are using the latest driver version 2 6 3 Update in Windows XP 1 Check that the USB Radio Dongle is connected Open the Windows Hardware Update Wizard for the Tritech TriBee USB driver by clicking Update Driver in the Tritech TriBee USB properties window 2 Select Don t search will choose the driver to install option and click Next Hardware Update Wizard Please choose your search and installation options Fates g O Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed Search removable media floppy CD ROM Include this location in the search Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 201
25. 01322 A Date 8 juli 2013 Aperio Online Installing the USB Radio Dongle Install USB radio dongle drivers in Windows 7 Follow these steps to install the USB radio dongle driver in Windows 7 For installation in Windows XP see section Install Radio dongle drivers in Windows XP on page 67 1 Connect the Aperio USB radio dongle device to a USB port on your laptop oe Tritech TriBee Zz USB dongle Other USB devices containing a radio like WLAN WiFi connected to the laptop should be placed as far away from the USB Radio dongle as possible If the radio link is weak use an USB extension cable or an external USB HUB 2 Window 7 will not be able to automatically install the USB Radio and will display a notification according to below or similar USB Device Not Recognized ax One of the USB devices attached to this computer has malfunctioned and Windows does not recognize it For assistance in solving this problem click this message 3 You must perform a manual installation in the Device manager Open the Control panel in Windows and click Device Manager GO gt Control Panel Hardware and Sound gt File Edit View Tools Help Control Panel Home z z 7 Devices and Printers a i iz System and Security Addadevice Adda printer Add a Bluetooth device Mouse Device Manager Network and Internet Hardware and Sound AutoPlay Change default settings for medi
26. 1 37 PM Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 65 Aperio Online Install USB radio dongle drivers in Windows Vista Follow these steps to install the USB radio dongle driver in Windows Vista 1 Connect the Aperio USB Radio Dongle device to a USB port on your laptop eo LZ Tritech TriBee Zz USB dongle Click Cancel in the Found new Hardware dialog Windows needs to install driver software for your TriBee USB Locate and instali Griver software recommended Windows will guide you through the process of installing driver software for your device gt Ask me again later Windows will ask again the next time you plug in your device or log on Don t show this message again for this device Your device will not function until you install driver software 3 Perform a manual installation similar to the Windows 7 installation procedure in section Install USB radio dongle drivers in Windows 7 on page 61 66 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Install Radio dongle drivers in Windows XP Follow these steps to install the USB Radio Dongle driver 1 Connect the Aperio USB Radio Dongle device to a USB port on your laptop eo Tritech TriBee Zz USB dongle 2 Select No not this time do not use Windows Update to search for software and click Next Found New Hardware Wizar
27. 14443B UID Enter new override credential Enter UID for the credential You may also enter a description of the credential UID The UID is entered using hexadecimal format For example 25A78FA4 11223344 Description Janitor UID Card number Description For example the credential owner Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 Aperio Online DESFire Enter new override credential Enter the credential in hexadecimal format File data The sector data is entered in hex format For example SS9AABBCCDD 1234ABCD Description Janitor File data The file data stored on the credential Description For example the credential owner ICLASS Enter new override credential Enter the credential in hexadecimal format Appended with zeros ifthe credential data does not fit into an even number of bytes For example 10 bit credential data 1111111101 Ls Appended with zeros 1111111101000000 L N nnn se IOI AN ia Ne cen le et nee cD fansa at Size in bits 1 144 10 1122 Credential Description Janitor Size in bits 1 144 Number of bits used for credential data on the iCLASS credential Credential Card credential appended with zeroes on the right side and translated to hexadecimal format Description For example the credential owner HID prox and EM prox Pa Enter new override credent
28. 16F1 Hormal address offset 1 DIP Switch EAC offline May 28 2013 4 32 18 PM hub with a combination of up to 8 locks sensors 1 Right click and select Communication hub Pair with lock or sensor File Scen Settings Letom Lock sensor Communication Hub EAC Address UHF Link 0216F1 Unknown 02452 aai Not paired with any device Configure Hub 024521 Communication Hub 024521 gt Pair with lock or sensor 00 17 7a 01 02 02 45 21 Upgrade Firmware Retrieve system information Office A Change radio channels Change EAC Address 6 0 22795 Change physical location name 1 2 6 Switch to Customer Mode 23 7 T Channel 25 2 475 GHz 11 16 25 4621 1 DIP Switch EAC offline Communication Hub 024521 not paired with any device RS485 Multiple Lock Aperio Legacy address offset USB Radio COM 10 May 28 2013 4 44 30 PM 2 The pairing process starts Hold the credential at the lock or engage the magnet for the sensor to pair the hardware with the communication hub Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Lock Show a card to the Aperio lock and wait for visual indication from the lock s LED When the LED have stopped blinking voU may click Done to see the pairing result Sensor Open the door to activate the sensor Click Done afterward to see the pairing result
29. 2410 3 hji T 0 8 HpER T E iczoc 14 21 2 Locate a communication hub by the last four characters of the communication hub MAC address ex 01CF in the scan result table The same characters should be on a label on the cover of the communication hub Click Rescan if the communication hubs that you want to configure are not shown in the list 3 Select the communication hub s that you want to include in your installation Click Show details to view detailed information in the installation view Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 9 Aperio Online 10 Got File Scan Settings Help Lock sensor Communication Hub EAC Address UHF Link 0216F1 Unknown j A a MAC Address Firmware Flavor Firmware Version Bootloader Version Radio protocol version Channel Radio channels PAN ID EAC addressing mode DIP switch value EAC Address Device Status USB Radio COM 10 Pairing locks sensors with communication AH30 version of the communication hub can be paired AH15 AH20 can manage one lock sensor src Not paired with any device Communication Hub 0216F1 not paired with any device Communication Hub 0216F1 00 17 7a 01 02 02 16 71 RS485 Aperio protocol 6 0 22795 1 2 5 23 19 2 445 GHz 14 19 25
30. 3 13 Aperio Online 3 Click Have Disk and Windows will guide you in three steps to select the Tritech USB driver folder located in the Aperio Programming Application program folder The content of this window can vary depending on what USB radio driver you currently have installed ardware Update Wizar Select the device driver you want to install for this hardware at g Select the manufacturer and model of your hardware device and then click Next If you fea have a disk that contains the driver you want to install click Have Disk Show compatible hardware Model Tritech TiBEE USB Version 2 0 0 0 2006 05 19 Tritech TriBEE USB Version 2 4 6 0 2008 03 13 A This driver is not digitally signed Tell me why driver signing is important 4 Click Browse navigate to the Aperio Programming Application folder and open the Tritech TriBee USB Driver folder CUT IIT EEE _ _ _ _ _ _ ___ Install From Disk Eg Insert the manufacturer s installation disk and then make sure that the corect drive is selected below Cancel Copy manufacturer s files from C Program Files 4ssa Abloy Aperio Programming v 1 Browse 5 For the Tritech TriBee USB bus Select the FTDIBUS driver file For the Tritech TriBee USB port Select the FIDIPORT driver filer Click Open aie Be My Recent Documents File name FTDIBUS Open My Network Files of type Setup Infor
31. 5 4521 Legacy ad _ 1 DIP Switcl 2 EAC offline 00 17 7a 01 0x12b9 USB Radio COM 10 June 19 2013 12 23 08 PM It is recommended to use the DIP Switch for setting the EAC address of communication hubs However if needed the Change EAC address function allows you to digitally assign an EAC address in the range of 1 63 1 15 for communication hubs with several locks sensors paired and 1 63 for communication hubs with one lock sensor paired Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 2 Click Save as to save the system information to a local storage Click Reset diagnostic counters to reset the 45 Aperio Online 46 i If the Programming Application is used to set RS 485 addresses it will override the address set by the DIP switch on the communication hub 1 Right click and select Communication hub Change EAC Address ic ee RS 485 Settings Select the EAC Address for this Communication Hub W gt EAC Address DIP Switch A Wl Select the EAC Address for this Communication Hub ee OOnA OO toh me ra oO vr 5 2 Select the address and click OK Changing the Security Mode Secure communication is normally set during first configuration of locks sensors and communication hubs with the configure wizard Security mode is also accessible through the right click menu During
32. Aperio Online Programming Application Aperio Online Table of Contents OTA Nach rearsa evra taste capicstnaete parsed nah oneciagutoradetics etephesinpndseavenalan ee Gaineneatentionccaciedieaisees 3 PUDO Sates ce sa saan aca ceceaeeh se E eee ace eas cade reenact marae neues 3 BG sea cscs E cst cope zacsb ac her anuscaasoasteuwessedes2i acstube uhesdevssstucetascieycsemeasiaesuctezcsseisnepaatoctaceearee 3 Applicable Products aca scee avn cay sp severance couseteenssus te scto vesdassaunsaceaavssundes step nicectusntearatoveeeiesas te nstairuntesteraerstiannumaneen nace 3 PUD VEL OMS ANG ATI OAS a AAA 3 FRI INS cc sss cence ceca E cece eect cee eee 3 ee Satire teen N N A EAEE OEE N AEEA A WRU FP 5S a A AE E E A ANE E A TE A AR 4 The Aperio programming applicatiOn sessssesesesssssssssssecsssssssssessteessssssssssstttesessssssststeresessssssertteressssssesttresressssssreres 4 Reculatory and security HNO I et gctesssyzcachesceasevcess asses staceas n ees 4 Communication hub versions and EAC interface csessssssssssesssessesssessssssessecssessscssesssessscssessecssesscesesssesseesseesses 4 3 me Fy Or ait Application Tye E Wassira RR 5 About the Programming Application sessssssseseessssssssseseeesssssssssseersessssssseseettresssssssseteteresnssssesertrernssssssnereresesssssseres 5 PAN OUN ae E E A E E E E E ete eee ees ea 5 EEE A E EE AET E E E EE AE OE A E 5 SS e E E I E AE E E E A E A E E EET 6 OU VETSION oian nce e
33. B Driver v Include subfolders gt Let me pick from a list of device drivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device 8 Depending on the windows system history regarding driver installations you may have to confirm driver installation If so select Install this driver software anyway Windows can t verify the publisher of this driver software w gt Don t install this driver software You should check your manufacturer s website for updated driver software for your device gt Install this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 63 Aperio Online 9 The first part of the installation is now done Windows has successfully updated your driver software Windows has finished installing the driver software for this device TriBee USB Serial Port 10 After the first part of the installation one or several notifications may be displayed and indicate that the unit has not been correctly installed This is normal and no corrections are necessary 11 Click Close in the dialog boxes to return to the Device Manager Navigate to Other Devices USB Serial Port right click
34. K Result The configuration is saved in the local storage and the Save configuration window is closed Clicking Cancel on the Device Update page does not affect the locally stored configuration Device Update The settings are now ready to be transmitted to Lock sensor You might need to Show card Engage sensor to Lock sensor Click Next The following updates will be transmitted to the Aperio Lock sensor Adding one override credentials Janitor MIFARE Classic 11111111 Remote open Activate Card read indication LED Time and date Current system time Save Configuration gt Next Applying a stored configuration to a communication hub lock sensor If you saved a configuration in the configuration wizard you can apply it to numerous locks sensors This function is available on both the Lock sensor menu and the communication hub menu and will only download settings that apply for the hardware selected Follow these steps to download a saved configuration to a lock sensor 1 Inthe Installation view right click the desired lock sensor and select Apply configuration and an earlier stored configuration Ameri pe File Scan Settings Help Lockjsensor Communication Hub EAC Address UHF Link Communication Hub 024521 MAC Address 00 17 7 a 01 02 Physical Location Office A Lock sensor 013542 0148ED Radio protocol version Com
35. K Cancel No settings are made to MIFARE Classic UID If you want to prevent MIFARE Plus UID from being read at all by the lock uncheck Use MIFARE Plus RFID MIFARE Plus Sector Select MIFARE Plus Sector in the RFID Card Type drop down list S Change MIFARE Plus configuration J Use MIFARE Plus RFID RFID Card Type MIFARE Plus Sector w Sector 1 Start Address in Sector 5 Length to read in Sector 15 MIFARE Authentication Key O01 122334455667788994ABBCCDDEEFF Read Key MIFARE Key A Start Address in Sector Parts of blocks within a sector can be used for credential data 0 to 47 for 1K MIFARE Classic credentials For 4K MIFARE Classic credentials 0 47 Start sector 0 to 31 and 0 239 Start sector above 31 Length to read in Sector Length of the credential data 1 48 Start sector above 31 we cannot use a credential larger than 48 bytes even though we have more blocks available in these sectors MIFARE Authentication Key A 16 bytes long hexadecimal key is required to read the credential data For example 00112233445566778899AABBCCDDEEFF Read Key Select the read key that the credential is configured to use for sector reading The lock will give access only for this key If key B is selected as sector data read key make sure that the access bits on the credential prevent reading of key B If key B is readable on the credential key B cannot be used to read the credential data Aperio O
36. No ST 001322 A Date 8 juli 2013 Aperio Online Legic UID Allowed card types At least one card type must be selected Prime ISO 15693 ISO 14443 4 Configuration type In the list select the card type to use Prime ISO 15693 Advant ISO 1443 A Advant No other settings are made to Legic UID Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 19 Aperio Online 20 Legic UID with data GE Change Legic configuration Allowed card types t least one card type must be selected v Prime Vv 150 15693 ISO 14443 4 Configuration type UID and data w Segment search Search string hex 30030009 Segment type Filter Access Start segment 0 Data Use the first byte of the search string as address 0 for Advant Start address 0 Number of bytes 8 Checksum Type CRC 16 bit Data start address 0 Data length 6 Checksum address 6 i Cancel In the list select the card type to use Prime ISO 15693 Advant ISO 1443 A Advant Select UID with data in the drop down list Segment search Search string hex Max 24 characters hexadecimal even number For example 30030009 Segment type filter The type of segment None Access or Data Start segment Specifies the segment from which to start the search It is useful in cases where more than one similar search string exists Inte
37. PM The following information is shown Lock sensor Indicates if there is a lock sensor paired with the communication hub If there is a paired lock sensor the MAC address of the lock sensor is shown Communication hub The MAC address of the communication hub EAC Address Shows the EAC address for the lock paired with this communication hub UHF Link Indicates the strength of the UHF wireless link through the USB Radio device between the communication hub and the Aperio Programming Application Green Good Yellow OK Red Not OK firmware upgrade not allowed Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 Fy Aperio Online Security Mode Indicates the security mode of the communication hub During final installation all locks and hubs must be changed from Manufacturer mode to Customer mode eS Customer mode Manufacturer mode Door is using secure radio Communication with the customer encryption key Door is using insecure radio communication with the default encryption key Warning indications The following warning levels are given Hoover with the mouse to see more information 0 Oo P For example Security mode for communication hub is undefined For example The communication hub firmware rfif version is older than Aperio Programming Application For example The communication hub is not paired with any lock For example The security mod
38. USB radio device connected to one of its USB ports The USB radio device enables the application to connect via a communication hub to the door lock The lock communicates via the communication hub either with the EAC or with the Programming Application Read more in the Aperio Online Programming Application Manual RS 485 SF or Wiegand EAC system Electronic Access Control Regulatory and security information See section 6 Regulatory Information Regarding the Aperio USB Radio Dongle on page 76 Communication hub versions and EAC interface There are four communication hub types according to the table below Maximum number of Version Interface i locks units AH15 Wiegand RS 485 1 AH20 Wiegand 1 8 1 AH30 RS 485 EAC address EAC address 1 15 15 63 The firmware type loaded into the communication hub controls what interface is enabled Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 pean 3 The Programming Application Overview About the Programming Application Software running under 32 bit or 64 bit versions of Windows 7 Windows 8 Vista or XP Java Runtime Environment 1 7 13 32 bit version bundled with Aperio Programming Application Multi language installation management tool Encrypted installation database Refer to section 5 Installation of Programming Application and Drivers on page 60 for installation and upgrade from earlier versi
39. a or devices Play CDs or other media automatically Sound Adjust system volume Change system sounds Manage audio devices Programs User Accounts and Family Safety Appearance and Personalization Power Options Change battery settings Change what the power buttons do Require a password when the computer wakes Change when the computer sleeps Choose a power plan Clock Language and Region Display Make text and other items larger or smaller Adjust screen resolution Connect to a projector Connect to an external display Ease of Access u OS Windows Mobility Center Adjust commonly used mobility settings Adjust settings before giving a presentation HP 3D DriveGuard P Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 61 Aperio Online 62 4 Navigate to Other devices TriBee USB and right click and select Properties File Action View Help e90 me ras a yg TobakPack2 gt i Acronis Devices gt gt Batteries gt 2 Biometric Devices gt Bluetooth Radios gt iil Computer e Disk drives b Display adapters gt fi DVD CD ROM drives gt Oe Human Interface Devices gt c IDE ATA ATAPI controllers p IEEE 1394 Bus host controllers gt lt Keyboards p A Mice and other pointing devices gt 5 Modems gt A Monitors gt Network adapters 4p Other devices Update Driver Software Disable Uninstall J ECP skr gt BD
40. age indicating if the driver installation was successful Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for F TiBEE USB Serial Port Click Finish to close the wizard 8 Ifneeded you can verify that the drivers for the TriTech TriBee USB USB Controller and the TriBee USB Serial Port Ports COM amp LPT are working by opening the Computer Management Control Panel Computer Management Give m Fie Action wiew Window Help ees E eaj 4 R m Computer Management Local JIRGENFALK 33D amp System Tools w Batteries H E Event viewer ig Computer Shared Folders S Disk drives 2 Local Users and Groups 2 Display adapters Performance Logs and Alert 3 DVD CD ROM drives 4 Device Manager Sy IDE ATAJATAPI controllers Sj Storage gt Keyboards i Removable Storage T Mice and other pointing devices Disk Defragmenter Disk Management Monitors Fa Services and Applications E E De Rh he ES Network adapters WY Ports COM amp LPT F Printer Port LPT1 TriBEE USB Serial Port COM3 BR Processors Sound video and game controllers 4 z System devices Intel R 82801FB FBM USB Universal Host Controller 2658 Intel R 82801FB FBM USB2 Enhanced Host Controller 265C Tritech TriBEE USB USB Root Hub USB Root Hub Aperio Online Programming Application Manual
41. and select Properties s 3 a File Action View Help File Action View Help 9 mAIRE G b P Network adapters a 5 Other devices iy Broadcom USH gt s i Smart card reade gt Sound video and gt Storage controlle p gil System devices PE Universal Serial Bus controllers Generic USB Hub g Intel R ICH9 Family USB Universal Host Controller 2934 g Intel R ICH9 Family USB Universal Host Controller 2935 g Intel R ICH9 Family USB Universal Host Controller 2936 g Intel R ICH9 Family USB Universal Host Controller 2937 g Intel R ICH9 Family USB Universal Host Controller 2938 Opens property sheet for the current selection 64 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 12 Repeat from step 5 until the second part of the driver is installed Windows has successfully updated your driver software Windows has finished installing the driver software for this device TriBee USB Serial Port 13 Reboot the computer 14 The installation is now complete If needed enter the Device Manager to verify that the correct driver version is installed for both the TriBee USB Serial Port COMx and the Tritech TriBee USB A check mark will appear in the left bottom corner after startup of the Programming Application showing the connection status with the USB Radio dongle Eile Scan Settings Help June 17 2013 3 0
42. annels To consider When changing radio channels all connected devices MUST be changed before the Communication hub is updated Wi 12 2 410 GHz 13 2 415 GHz 14 2 420 GHz 15 2 425 GHz 16 2 430 GHz 17 2 435 GHz 18 2 440 GHz 19 2 445 GHz 20 2 450 GHz 21 2 455 GHz 22 2 460 GHz 23 2 465 GHz 24 2 470 GHz 25 2 475 GHz 26 2 480 GHz 3 Hold the credential at the lock or engage the magnet for the sensor to perform the update Show card Engage sensor Time remaining until timeout 15 seconds Result A progress bar shows that the update is being performed The Device update result dialog box shows the result of the update when it has been performed successfully updated radio channels 4 Repeat this procedure for all locks sensors connected to the current communication hub Recommendation Although it is possible to set different channels to locks sensors paired with one hub it is preferable to use the same three channels for all locks sensors on that communication hub in order to create a more stable radio connection Communication problems occur more likely between closely installed hubs than between closely installed locks sensors paired with one hub Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 49 Aperio Online 5 Finally change the radio channel for the communication hub Right click and select Co
43. ardware are ignored Click Close to finish Successful Remote open Ignored a Adding one override credentials Card read indication wy Xo Time and date 6 Repeat all the steps from the beginning of this section for every lock sensor you want to configure with a saved configuration Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 39 Aperio Online 40 Change physical location name communication hub lock sensor This function applies to both communication hubs and locks sensors In the example below the physical location name is changed for a lock sensor 1 Right click and select Lock sensor Change physical location name 5 File Scan Settings Help Lock sensor Communication Hub EAC Address UHF Link Communication Hub 024521 011043 MAC Address 1 Lock sensor 013542 b Apply configuration p tion Communication Hub 024521 Configure por Retrieve system information sion 6 0 22795 Upgrade Firmware ersion 1 2 5 Get Event Log Get Audit Trail al version 23 25 2 475 GHz Change radio channels als 11 16 25 Switch to Manufacturer Mode 4521 Change physical location name ng mode Legacy addre ilue 1 DIP Switch Unpair lock sensor from communication hub Remote open is activated Number of paired locks and sensors 3 Device Status EAC offline Lock sensor 013542 MAC Address 00 17 7a 01 02
44. ate 8 juli 2013 23 Aperio Online Advanced settings Keypad configuration Lock This window is only visible if Show advanced settings is activated in User Settings window see section User settings on page 6 1 Click Change to enter specific Keypad configuration Keypad configuration Set the keypad configuration if needed Click Next to continue Change Keypad configuration 2 Choose between two reading modes Enable Keypad PIN reading mode Fixed length w Enter PIN length 4 Fixed length PIN is set to use a fixed length Enter PIN length A value between 1 and 16 as specified by the EAC Enable Keypad PIN reading mode End Character w End character PIN is sent to the EAC after an end character is pressed Select Character One of the non numeric characters on the keypad can be used to submit the pin For example The user enters the PIN followed by a on the keypad 24 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Override credential Lock The override credentials are used to gain access to an area when the EAC is offline or when the lock has lost connection with the communication hub Only the credentials from the override list will be granted access when the system is offline You may add 10 override credentials to a door Use of override credentials when using a Wiegand
45. b 3 Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 31 Aperio Online 32 Lock access decision timeout SE Change lock access Lock access decision timeout 2 This value sets the time in seconds the lock will wait for an access decision from the EAC i If this time is extended and the HUB is offline the response time when using the PAP will be longer This is due to that each swipe of a credential will wait for the EAC response and with a longer timeout the response in offline will also increase Remote open G Remote open configuration Weessersecesecccssenscsesnnnescesenccebsnscceed Default unlock duration for Wiegand 8 hours and 0 minutes Checking the Enable remote open checkbox will enable the remote open functionality in the HUB As the wiegand interface does not support setting an unlock duration from the EAC this must be configured here C Checking the Enable DIP Switch checkbox will restore the EAC addressing to what is configured with the DIP switches on the communication hub To disable the DIP switch the EAC address must digitally be set as well To do this use the Change the EAC address function on the right click menu for the communication hub Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Advanced setting Radio channel settings Communication hu
46. b or Lock sensor i Always change the radio channel on the lock before changing on the communication hub This function is also available on the right click menu in the installation view 1 Click Change to set the radio channel the communication Advanced Settings Change settings if needed 12 2 410 GHz 13 2 415 GHz 14 2 420 GHz 15 2 425 GHz 16 2 430 GHz 17 2 435 GHz 18 2 440 GHz Current radio channels in de are channels Settings 19 2 445 GHz 20 2 450 GHz 21 2 455 GHz 22 2 460 GHz 23 2 465 GHz 24 2 470 GHz 25 2 475 GHz 26 2 480 GHz 2 Deselect one or several of the used channels to make a new selection of channels i For the US market channel 26 is disabled Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 Aperio Online 34 Advanced Lock sensor Settings On this page you will be able to configure Battery Power Alarm Interval Status Report Interval Locking Parameters Card Read Indication and Sensor Events Advanced Lock sensor Settings Change settings if needed Click Next to continue Battery Power Alarm Interval Change Status Report Interval Change Locking Parameters Change Card Read Indication Change Sensor Events Change Ca e Configure Battery Power Alarm are Batter Power Alar interval mx Battery Power Alarm Interval The value below
47. ble to version 2 6 4 of the Aperio Online Programming Application Abbreviations and Definitions Applicable Products This manual can be used for all versions of communication hubs Abbreviation Definition EAC Electronic Access Control The system controlling access decisions DIP Dual in line Package A manual electric switch used for settings on the communcation hub RFID Radio Frequency Identification The credential technology used References 1 ST 001323 Aperio Online Mechanical Installation Manual 2 ST 001322 Aperio Online Quick Installation Guide Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 Aperio Online Figure 1 Aperio technology overview 2 System Overview Programming application J IEEE802 15 4 2 4GHz Communication Hub The Aperio system The Aperio system is used in the following way The user holds an RFID card in front of the lock The lock sends card credentials wirelessly to the communication hub and the communication hub wired through RS 485 or Wiegand then communicates with an EAC Electronic Access Control system The EAC system then makes the access decision The decision is sent via the communication hub to the lock and access is granted or denied The Aperio programming application The Programming Application is used for the configuration of a door installation It is installed on a laptop The laptop has an Aperio
48. ck will be open in seconds default 5 s Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 35 Aperio Online 36 Lock jammed alarm timeout seconds How long time the system tries to lock the lock before it sends an alarm to the EAC and goes back to idle state Enable lock jammed retry This enables a periodic retry to lock the lock according the settings under Lock jammed retry period seconds Lock jammed retry period seconds How long the lock will wait before it retries to lock the lock in seconds default 2 s Lock jammed indication mode The way in which the lock indicates that it has been jammed LED Buzzer and LED and buzzer are the different indication modes Configure Card Read Indication S2 Configure Card Read Indication x Card Read Indication Configure the way in which the lock indicates a card read Please note that you must know what card read indication capabilities the selected lock has since not all options here might be applicable to every type of lock Initial values shown here are just default values The actual configuration is never read from the lock seectsssensncesenssssensessessnnssssnnasssessnsssssnssssnsnssesnsnssssssnssssseee Different locks can have a different mechanism for audio visual indication of successful credential reading Here it is possible to disable credential read indication or to set it to LED Some Aperio
49. credential at the lock or engage the magnet for the sensor Show card Engage sensor ma Time remaining until timeout 13 seconds File Scan Settings Help EAC Address UHF Link 00 17 7a 01 02 02 45 21 Office A RS485 Multiple Lock Aper 6 0 22795 1 2 5 23 25 2 475 GHz 11 16 25 4521 Legacy address offset 1 DIP Switch 3 EAC offline 00 1 7 7 a 01 02 01 35 42 0x1230 1 May 14 2013 12 30 14 PM Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 Aperio Online 3 Inthe audit trail window click Save As to save the information to a txt file or click Close to exit without Saving Audit Trail for Lock sensor 013542 Created May 14 2013 12 30 35 PM CEST Number Date March 14 2013 10 17 40 AM CET Access denied Classic March 14 2013 10 24 26 AM CET Access denied Classic May 14 2013 10 47 09 AM CEST Access denied Classic May 14 2013 10 48 39 AM CEST Access denied Classic May 14 2013 10 49 21 AM CEST Access denied Classic May 14 2013 10 50 29 AM CEST Access denied Classic May 14 2013 11 46 40 AM CEST Access denied Classic May 14 2013 11 49 42 AM CEST Access denied Classic May 14 2013 11 50 09 AM CEST Access denied Classic May 14 2013 11 52 11 AM CEST Access denied Classic r Zu 3 4 5 6 T 6 9 10 The window contains information on the total number of access attempts including consecutive number
50. d Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Can Windows connect to Windows Update to search for software O Yes this time only Yes now and every time connect a device O No not this time Click Next to continue This wizard helps you install software for Tritech TiBEE USB E If your hardware came with an installation CD lt 6 or floppy disk insert it now What do you want the wizard to do O Install the software automatically Recommended Click Next to continue Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 67 Aperio Online 4 Select Search for the best driver in these locations Unselect Search removable media select Include this location in the search and click Browse Found New Hardware Wizard Please choose your search and installation options Fates y Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed C Search removable media floppy CD ROM Include this location in the search x Don t search will choose the driver to install Choose this option to select the
51. d Select the RFID type you want to configure from the tabs below Changes to be sent Remove changes Add Change Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online MIFARE Classic UID Default amp Change MIFARE Classic configuration 7 Use MIFARE Classic RFID RFID Card Type MIFARE Classic UID w No parameters available OK Cancel No settings are made to MIFARE Classic UID If you want to prevent MIFARE Classic from being read at all by the lock uncheck Use MIFARE Classic RFID MIFARE Classic Sector Select MIFARE Classic Sector in the RFID Card Type drop down list amp Change MIFARE Classic configuration J Use MIFARE Classic RFID RFID Card Type MIFARE Classic Sector w Sector 1 Start Address in Sector 5 Length to read in Sector 15 MIFARE Authentication Key 112233445566 Read Key MIFARE Key w Start Address in Sector Parts of blocks within a sector can be used for credential data 0 to 47 for 1K MIFARE Classic credentials For 4K MIFARE Classic credential 0 47 Start sector 0 to 31 and 0 239 Start sector above 31 Length to read in Sector Length of the credential data 1 48 Start sector above 31 we cannot use a credential larger than 48 bytes even though we have more blocks available in these sectors MIFARE Authentication Key A 16 bytes long hexadecimal key is r
52. d the device resets ey x Firmware 4 Lock Main Application F Lock Main Application 6 1 19489 Firmware Version 6 1 19489 Lock UHF C Progress Information 2 3 18976 Resetting device Lock Secure Area F bin Ho 4 2 6 18976 u Cose Retry 12 Click Next to continue with the next firmware in the list Or click Close to cancel the rest of the firmware upgrade process Firmware Lock Main Application Lock Main Application 6 1 19489 Firmware Version 6 1 19489 Lock UHF Progress Information 2 3 18976 Done gt Lock Secure Area 2 6 18976 Firmware Lock Main Application Lock Secure 4rea amp 1 19489 4 as Firmware Version 2 6 18976 Lock UHF Progress Information aa Pe lel Fas Done Lock Secure Area SS aay 2 6 18976 58 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Upgrade failure A failed update is typically due to bad radio conditions The work around is to move the USB Radio closer to the communication hub and try update again 1 Click Save support information to file if desired and click OK to close the error message No response was received from the device This could be caused by radio disturbances please try again Save support information to file gt Firmware Lock Main App
53. date access decision and what type of credential that was used at each attempt Retrieve system information This function is available for both communication hub and lock sensors File Scan Settings Help Communication Hub EAC Address UHF Link Communication Hub 024521 0216F1 Unknown MAC Address 00 17 74 01 Lock sensor 0148ED a Physical Location Office A Communication Hub 024521 gt Apply configuratio gt le Flavor RS485 Mul Configure e Version 6 0 22795 Upgrade Firmware Pair with lock or sensor der Version 1 2 5 lhe version 23 11 2 405 G Change radio channels hannels 11 16 25 Change EAC Address 4521 Change physical location name Jressing mode Legacy ad Switch to Manufacturer Mode ch value 4 T Retrieve system information EAC Address DIP Switci Number of paired locks and sensors 2 Device Status EAC offline Lock sensor 0148ED MAC Address 00 17 7a 01 Assigned Address 0x12b9 EAC Address 1 Radio protocol version 23 Device Status Lock sens m r USB Radio COM 10 June 19 2013 12 23 50 PM 1 Right click and select Lock sensor or Communication Hub Retrieve system information to access the unit Please wait 44 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online device or click Close to exit System information for Communication Hub 024521 Office
54. de ete A EA E EREA 6 USB radio Indi ON seinan AR E S T ETTO V W OVE NO N eea E E E AA T A Programming Application FUNCTIONS uu cccccessecsessecsesessessesecsscsessesseeseesssscseseessesssseeseeseeseesceneenee 9 Openingjcreating INSTANT OMS i ccscassccivsaiadeaseassvocsvssodedestiosossusisessedensdaueardsstorsquedsssovdsxoucansabdouconbvanotdsseguessthssoekaasensevesdaeede 9 Scanning and adding communication hubs s5 scsscosscsscosscacesvesssesseatsastostceuteatasessscocetecoueatosstesseeaeseserstecvsunseraad ies 9 Pairing locks sensors with communication MUD iscassesazstiossucsectasuesssnesoacesssetoderucisnssdsnnsinasssateacddstaasesnrensessoinstncrss 10 CONE TR WUC CHO Wiza siesena E E 12 Applying a stored configuration to a communication hubflock Sensor uu eessessessesseeseeseeseeseesseeseessee 38 EUS VO C1 SINS OF TINC ON ranr E A AE eenesim ntensetnenaees 41 Remieve systemi IVAN OU IM UCI sereu A E S terete 44 CHINE EAC AN a a A E E EEE ned nee A EEA N 45 Changing the Security ModE sessissninnran enaa a a A 46 Changing the radio channel S eens EAA E A 48 SENE DE UMEO a lOG r AN R E EER 51 importing and exporting CO MMMM NE ONS saci adessesccsaseasacsancapa a cncaatiadesscovesussastdoanee ooassuaietasesseeaensec e iniaa Seinas 53 Upgrade of communication Hub lOck SENSOF firmware ccseessessesseessessessessscssessecssessessecsscsnsesecsecssceseeseesseees 55 Installation of Programming Application and Drivers ccccsssessessessesecsessss
55. device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware 5 Select the Tritech TriBee USB Driver folder located in the Aperio Programming Application main folder Click OK and then Next in the Found New Hardware Wizard Browse For Folder Je Select the folder that contains drivers for your hardware Program Files Assa Abloy B Aperio Programming Application O aperioinstallations E Common Files Lanha Jewkenbions iss 3 To view any subfolders click a plus sign above 6 After the installation is done click Finish Found New Hardware Wizard Found New Hardware Wizard Please wait while the wizard installs the software C ompl etin g the Found New Hardware Wizard The wizard has finished installing the software for Tritech TriBEE USB Tritech TriBEE USB Do 2 Setting a system restore point and backing up old files in case your system needs to be restored in the future Click Finish to close the wizard Result The system now displays the installation procedure for the TriBee USB Serial Port 68 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 7 Repeat steps 2 6 of this procedure for the serial port driver When done click Finish Result Windows has installed the drivers and the hardware is ready to use Windows shows a pop up mess
56. e default mode is Manufacturer mode but you should always change it to Customer mode If you change to Manufacturer mode key the lock will no longer be using secure radio communication 30 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online RS 485 settings Communication hub For use of RS 485 there are the following options Click Change for each option to enter the settings ial amp Configure Communication Hub 024521 Eza Electronic Access Controller Settings Change settings if needed Click Next to continue EAC addressing mode Legacy address offset Lock access decision timeout Remote open Remote open is inactivated Enable EAC Address via DIP Switch DIP Switch enabled EAC addressing mode Normal address offset EAC address is in omer 7 2 3 The default EAC addressing mode is Normal address offset which means that the communication hub assigns the EAC address to the paired locks according to the addressing table see the Aperio Online Mechanical Installation manual This setting is used when the EAC can handle addresses without limit Legacy address offset is used when the EAC has a low limit for handling addresses for example 32 or 64 The following example shows the addresses assigned to the locks on a communication hub with address 1 Normal address offset 1 17 33 49 Legacy address offset 1 8 hub 1 9 16 hub 2 17 24 hu
57. edential reading you need to set first the Application Id of the application which contains the file A credential can have up to 32 applications Application Ids range from 0 to 16777215 File Identity You need to type the File Id of the file you want to read Every application can have up to 28 files File Ids range is 1 to 255 File Start Position You need to indicate the byte index where you want to start to read the file If you type 0 it will start from the beginning of the file Length to read in File Type the length of the data you want to read The length is specified in bytes Minimum length is 1 and the maximum length supported by the Aperio lock is 48 bytes File Data Protection Level Select one of the three options Plain Data Authenticity by MAC Full Encryption depending on the data type of the file Key Type Select one of the four options DES 2K3DES 3K3DES AES 128 depending on the crypto used by your application s key Type the key value in hexadecimal DES 2K3DES and AES 128 are 16 bytes keys 3K3DES is a 24 bytes key Key Number Each application can store up to 14 keys Key 0 is always the application s master key Enter which key number from the application you want to use Key numbers range from 0 to 13 Example KEW AES 128 nr AID 1235 001122 3344556607 TEROSAABECCDDEEFF FID 1 DO Ef FID 2 Encrypted 17101980 FID 3 PO Aperio Online Programming Ap
58. equired to read the credential data For example 00112233445566778899AABBCCDDEEFF Read Key Select the read key that the credential is configured to use for sector reading The lock sensor will give access only for this key O If key B is selected as sector data read key make sure that the access bits on the credential prevent reading of key B If key B is readable on the credential key B cannot be used to read the credential data Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 13 Aperio Online Example To read the user data shown in the figure below 17 10 19 80 and use the Authentication Key 001122334455 together with MIFARE Key A Byte Number within a Block Description Sector Trailer 15 sector Trailer 14 Data Data Sector Trailer 1 Data Data Data Access Bits sector Trailer 0 Data Data The configuration should look like this g SA Change MIFARE Classic configuration Use MIFARE Classic RFID RFID Card Type MIFARE Classic Sector w Sector 14 Start Address in Sector 17 Length to read in Sector 4 MIFARE Authentication Key 001 122334455 Read Key MIFARE Key w 14 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online MIFARE Plus UID SA Change MIFARE Plus configuration fea 7 Use MIFARE Plus RFID RFID Card Type MIFARE Plus UID w No parameters available O
59. es in communication hub and lock are not equal and should be changed see section Change EAC address on page 45 Detailed information of selected hub and lock sensor is shown on the right side of the window Right clicking a communication hub or lock sensor will give access to the functions available in the Programming Application See chapter 4 Programming Application Functions on page 9 for an overview of all functions SA Aperio Programming Application New_installation oc e File Scan Settings Help _ Lock sensor Communication Hub EAC Address UHF Link Communication Hub 0216F1 e s Apply configuration gt MAC Address 00 17 7 4 01 02 02 16 11 Configure Firmware Flavor RS485 Aperio protocol Firmware Version 6 0 22795 Lock sensor 011043 gt Bootloader version 1 2 5 Communication Hub 0216F1 gt Pair with lock or sensor Radio protocol version 23 Upgrade Firmware Retrieve system information Channel 19 2 445 GHz i Radio channels 14 19 25 Change radio channels PAN ID 16F1 Change EAC Address i EAC addressing mode Hormal address offset Change physical location name DIP switch value 4 Switch to Customer Mode EAC Address DIP Switch Number of paired locks and sensors 4 Device Status EAC offline Lock sensor 011043 MAC Address 00 17 7 a 01 02 01 1 43 Assigned Address Ox117e EAC Address 1 Radio protocol version Unknown USB Radio COM 10
60. ger in the range of 0 255 Data Use the first byte of the search string as address 0 for Advant Only for Advant card types in order to change the data addressing of Advant The first data byte will be the first search string stamp byte Start address Specifies the start address of the data Integer in the range of 0 255 Number of bytes Specifies the number of bytes of data to be read Integer in the range of 1 45 Checksum Type None does not require any of the checksum related fields to be specified but CRC 8 bit and 16 bit does Data start address Specifies the address where the data which checksum is to be calculated starts Integer in the range of 0 255 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Data length Specifies the length of the data in number of bytes to be read Integer in the range of 0 255 Checksum address Specifies the address where the checksum is located Integer in the range of 0 255 The credential data start address differs between Legic Prime and Legic Advant For Legic Prime cards the first data byte starts with the first search string stamp byte For Legic Advant cards the first data byte starts with the first byte in the data area Example Legic Advant Card Segment 0 Search String 30 03 00 08 Segment type Data Data length 8 bytes Checksum CRC 16 byte 0 5 Checksum address 6 S Change Legic config
61. gramming Application Serial port settings Automatically detects USB radio at start up Uncheck this option to manually specify the port used by the USB Radio Dongle in case of hardware conflict Advanced settings Check this box if you need to perform advanced hub and lock configurations keypad configuration advanced settings changing the radio channel and advanced lock settings Log Level Settings Used for trouble shooting purposes Contact your Aperio supplier for more information Software version To check the version of installed software select About Aperio Programming Application on the Help menu Aperio Programming Application ASSA ABLOY Copyright 2007 2013 ASSA ABLOY All rights reserved httpuwww assaabloy com Programming Application version 9 0 24449 Gi Build number 1 0 0 24449 Revision 24449 Aperio radio protocol version 23 This is a legal agreement between you the end user and ASSA ABLOY W re e S S Ifyou do not agree to the terms ofthis agreement please return the a LICENSE AGREEMENT package and the accompanying items including written material and binders or other containers to the place you obtained them for a full O C K refund 1 GRANT OF LICENCE te G h nN O O g y ASSA ABLOY permits you to use one copy ofthe software on one single computer or on a single hard disk for use by you in a local network Aperio Online Programming Application Ma
62. h string as address 0 for Advant or Allowed card types At least one card type must be selected Prime ISO 15693 ISO 14443 4 Configuration type UID and data w Segment search Search string hex 30030009 Segment type filter Access 2 yrl Start segment o Data Use the first byte of the search string as address 0 for Advant Start address 0 Number of bytes 24 Checksum Type CRC 16 bit Data start address 0 Data length 11 Checksum address CEI Gea Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Example Legic Prime Card Segment 0 only segment Search String 30 03 00 08 Segment type Data Data length 8 bytes Checksum CRC 8 byte 0 6 Checksum address 7 Allowed card types At least one card type must be selected Prime ISO 15693 ISO 14443 4 Configuration type UID and data w Segment search Search string hex 30030008 Segment type Filter None Start segment o rData Use the first byte of the search string as address 0 for Advant Start address 0 Number of bytes 8 Checksum Type Data start address Data length Checksum address Aperio Online Programming Application Manual Document No ST 001321 A D
63. hexadecimal format Description For example the credential owner Legic UID cnter new oVverriage credenti Enter new override credential Enter data for the credential You may also enter a description of the credential UID The UID is entered using hexadecimal format For example 25A78FA4 123454BCDE Description Janitor UID Card number Description For example the credential owner Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 29 Aperio Online Legic Data Enter new override credential Enter data for the credential You may also enter a description of the credential Data The sector data is entered in hex format For example S9AABBCCDD 11222663 RABB Description Janitor Data Sector data stored on the credential Description For example the credential owner Security Mode Settings Communication hub and Lock sensor This setting will apply for both the communication hub and the lock if only one lock is paired Security Mode Setting Set the security mode that will be used for encrypted radio communication Click Next to continue Security Mode Setting Security mode will not be changed 1 Click Change in the Security Mode Setting area if you want to change the security mode or click Next 2 To change to customer mode check the checkbox and click OK Th
64. ial Enter the credential in hexadecimal format Appended with zeros ifthe credential data does not fit into an even number of bytes For example 10 bit credential data 1111111101 Appended with zeros 1111111101000000 L N nnn Ne IOI AO is Ne cen cl ee nee cD fassa at J Size in bits 1 144 10 FF40 Credential Description Janitor Size in bits 1 144 Number of bits used for credential data on the credential Credential Card credential appended with zeroes on the right side and translated to hexadecimal format Description For example the credential owner 28 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Enter new override credential Enter the PIN for the credential PIN 22323 Description Janitor PIN PIN code Description For example the PIN user Seos Enter new override credential Enter the credential in hexadecimal format Appended with zeros ifthe credential data does not fit into an even number of bytes For example 10 bit credential data 1111111101 Appended with zeros 1111111101000000 Le eee ee TIT ALO in bawasadaaisaal Fes wenn ed Size in bits 1 384 10 1111 Credential Description Janitor Size in bits 1 384 Number of bits used for credential data on the credential Credential Card credential appended with zeroes on the right side and translated to
65. itch Remote open is activated Number of paired locks and sensors Device Status Lock sensor 0148E8 MAC Address 00 17 7a 01 02 01 48 e8 Floor 1 Door 414 Assigned Address 0x11fd EAC Address 2 Radio protocol version 23 Physical Location USB Radio COM 10 May 14 2013 11 49 10 4M Other lock sensor functions Get Event Log This function displays the event log for a particular lock not available for sensor where you can find all system events performed on the lock 1 Right click and select Lock sensor Get Event Log File Scan Settings Help Lock sensor Communication Hub EAC Address UHF Link 0216F1 Unknown Communication Hub 024521 0148ED Lock sensor 0148E8 Communication Hub 024521 Upgrade Firmware MAC Address Physical Location Apply configuration Configure Retrieve system information Get Event Log Get Audit Trail Change radio channels Switch to Manufacturer Mode Change physical location name Unpair lock sensor from communication hub Device Status 00 17 74 01 02 02 45 21 Office A RS485 Multiple Lock Aperio protocol 6 0 22795 1 2 5 23 25 2 475 GHz 11 16 25 4521 Legacy address offset 1 DIP Switch 2 EAC offline Lock sensor 0148E8 MAC Address Assigned Address EAC Address Radio protocol version Device Status USB Radio COM 10 00 17 7a 01 02 01 48 e8 0x12c5
66. lication 0 Lock Secure Area 6 1 19489 a F Firmware Version 2 6 18976 Lock UHF Progress Information 2 3 18976 O 0 q gt Lock Secure Area F 2 6 18976 Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 59 Aperio Online 60 5 Installation of Programming Application and Drivers Installation of the Programming Application and USB radio dongle Computer specifications The Aperio Online Programming Application should be installed on a computer with the following specifications Laptop 32 64 bit version of Windows 7 Windows 8 Vista or XP USB 2 0 Files needed for the installation Aperio Programming Application software version 2 6 4 X Encryption key file These files should be delivered from your lock distributor Installing the Programming Application Follow these steps to install the Programming Application and the drivers necessary for installation of the Radio dongle 1 Unpack the Aperio distribution file i e progapp x y z zip progapp_US x y z zip including the setup exe file in atemporary folder 2 Run the setup exe file Result The Aperio Programming Application is installed and necessary drivers for the Radio dongle are copied to the computer The Aperio Programming Application is bundled with Java so no separate Java installation is required Aperio Online Programming Application Manual Document No ST 0
67. lock and communication hub where the lock interval should be shorter than the interval in the communication hub This is to ensure that no intermittent offline situations occur When using an AH30 communication hub it is also important that all locks have the same status interval as the communication hub will only have one offline interval for all locks paired Locking Parameters Configure Locking Parameters Try to unlock timeout seconds The time the lock tries to unlock until it returns a failure if itis not possible Lock open time seconds The time period during which the lock is open Lock jammed alarm timeout seconds Time period during which the main controller constantly tries to lock a jammed lock until it sends a Lock Jammed Alarm to the EAC system and returns to sleep mode Lock jammed retry period seconds Time between the retries in lock jammed mode Lock jammed indication mode The way in which the lock indicates that it has been jammed Try to unlock timeout seconds 2 Lock open time seconds 5 Lock jammed alarm timeout seconds 30 4 Enable lock jammed retry Lock jammed retry period seconds 60 Lock jammed indication mode LED Buzzer Ca LED and buzzer Here you configure timing for different operations in the lock Try to unlock timeout seconds How long the lock tries to unlock before it returns a failure Lock open time seconds How long the lo
68. mation inf 6 After the installation process of the USB bus driver repeat steps 1 5 for the Tritech TriBee USB port driver 4 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 7 Reboot Windows To check the new driver versions open the properties dialog in the Computer Management Control panel again for the two TriTech TriBee USB drivers Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 15 Aperio Online 6 Regulatory Information Regarding the Aperio USB Radio Dongle Compliance This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions this device may not cause harmful interference and this device must accept any interference received including interference that may cause undesired operation Changes or modifications made to this equipment not expressly approved by Tritech Technology AB may void the FCC authorization to operate this equipment According to FCC15 247 To comply with RF exposure compliance requirements the device must not be co located Or operating in conjunction with any other antenna or transmitter Security Statement The following security measures are applicable to Aperio Authentication Confidentiality in communication Confidentiality of information in the lock Encryption key
69. mmunication Hub Change radio channels r o hms File Scan Settings Help Communication Hub EAC Address UHF Link Communication Hub 024521 0216F1 t ew ERFA MAC Address 00 17 7 4 01 02 Lock sensor 013542 Oo a azala Physical Location Office A Communication Hub 024521 gt Apply configuration Firmware Flavor RS485 Multipl Configure Firmware Version 6 0 22795 Upgrade Firmware as Pair with lock or sensor Bootloader Version 1 2 5 Radio protocol version 23 Channel 11 2 405 GHz Change radio channels Radio channels 11 16 25 Change EAC Address PAN ID 4521 Retrieve system information Change physical location name EAC addressing mode Legacy addre Switch to Manufacturer Mode DIP switch value 4 EAC Address DIP Switch Remote open is activated Number of paired locks and sensors 3 Device Status EAC offline Lock sensor 013542 MAC Address 00 17 7 a 01 02 Assigned Address 0x1230 EAC Address 1 Radio protocol version 22 USB Radio COM 10 May 14 2013 12 54 54 PM 6 Uncheck any of the three currently used channels to be able to select the same radio channels as for the lock sensor Click OK Result A progress bar shows that the update is being performed The Device update result dialog box shows the result of the update when it has been performed Please wait 50 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli
70. munication Hub 024521 gt Apply configuration Default hub installation Upgrade Firmware Sonfigure 1 2 5 Pair with lock or sensor bi Retrieve system information 25 2 475 GHz Change radio channels aba Change EAC Address an Change physical location name ae adare Switch to Manufacturer Mode i 1 emo muuu DIP Switch Number of paired locks and sensors 3 Device Status EAC offline Lock sensor 013542 MAC Address 00 17 74 01 02 Assigned Address 0x1230 EAC Address 1 22 r USB Radio COM 10 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 May 14 2013 11 21 24 4M Aperio Online 2 Click Confirm to start the transfer N By The following settings will be transmitted to Communication Hub You might need to Show card Engage sensor to Communication Hub Click Confirm to proceed Adding one override credentials Janitor MIFARE Classic 11111111 Remote open Activate Card read indication LED Time and date Current system time 3 Wait for the transfer to finish Please wait 4 Hold the credential at the lock or engage the magnet for the sensor to accept the configuration This will not be required when downloading configuration to a communication hub Show card Engage sensor Time remaining until timeout 14 seconds 5 The result is shown The settings that could not be transferred to the specific h
71. nline Programming Application Manual Document No ST 001321 A Date 8 juli 2013 15 Aperio Online 16 Example Since MIFARE Plus has the same memory organization as MIFARE Classic we can use the same configuration We will also use Key A but here the length of this key should be 16 bytes in this particular case 00112233445566778899AABBCCDDEEFF The configuration should look like this Use MIFARE Plus RFID RFID Card Type MIFARE Plus Sector w Sector 14 Start Address in Sector 15 Length to read in Sector 4 MIFARE Authentication Key 001122334455667788994ABBCCDDEEFF Read Key MIFARE Key 4 DESFire UID 5 e DE d Use DESFire RFID RFID Card Type DESFire UID w No parameters available No settings are made to DESFire UID If you want to prevent DESFire from being read at all by the lock uncheck Use DESFire RFID Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online a SA Change DESFire configuration DESFire Select DESFire in the RFID Card Type drop down list p V Use DESFire RFID RFID Card Type DESFire X Application Id 1 File Identity 2 File Start Position 12 Lenath to read in File 6 File Data Protection Level Data authenticated by MAC w Read Key Configuration Key Type 4ES 125 v 001122334455667738899iaBBC Key CDDEEFF Key Number 0 Application Id To configure the lock for file cr
72. not be saved Only save settings that are general for all locks in your installation Tip Create a set of configurations for the most common settings in your system Save Configuration Save configuration to local storage Select the configurations in the table below that you want to save Then choose a name for the setting and click OK to save Configuration name Default hub installation Include configurations 7j Adding one override credentials Remote open 7 Vv Card read indication 7 Time and date 3 Enter a unique and suitable name for this configuration in the Configuration name field Choose this name carefully to make it clear what settings are changed in the lock sensor or communication hub You could for instance name it according to the different configuration tasks or if applicable use a name that reflects the specific door type gt Save Configuration Save configuration to local storage Select the configurations in the table below that you want to save Then choose a name for the setting and click OK to save Configuration name Default hub installation Include configurations 7 Adding one override credentials Remote open yj Vv Card read indication 7 Time and date Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 37 38 Aperio Online 4 Click O
73. nual Document No ST 001322 A Date 8 juli 2013 Aperio Online USB radio indication USB Radio together with a green check mark indicates that the serial port used is ok and the radio device is ready to transmit data USB Radio COM 10 USB Radio together with a red dot indicates that the serial port or the USB radio device is not ok 9 USB Radio Installation View overview The installation view is the main window when working with door installations This window is automatically displayed after logging in to an installation and after the scanning process To display it manually enter the Views menu and select Installation view ile Scan Settings Help Lock sensor Communication Hub EAC Address UHF Link Communication Hub 0216F1 0216F1 e 8 013542 e 3 0 0148E8 6 v Firmware Flavor RS485 Aperio protocol MAC Address 00 17 7a 01 02 02 16 11 0148ED Es Firmware Version 6 0 22795 Bootloader version 1 2 5 Radio protocol version 23 Channel 19 2 445 GHz Radio channels 14 19 25 PAN ID 16F1 EAC addressing mode Hormal address offset DIP switch value 4 EAC Address DIP Switch Number of paired locks and sensors 4 Device Status EAC offline Lock sensor 011043 MAC Address 00 17 7a 01 02 01 1 43 Assigned Address 0x115e EAC Address 1 Radio protocol version 23 Device Status Lock sensor offline USB Radio COM 10 May 14 2013 3 48 55
74. ons Main view The main view of the Programming Application consists of three areas Menu bar View area Status bar s sss aaa a J Communication Hub 9 M e n LI ba r 0216F1 a I I I I I I I I I I I I View area I I I I I l I I I I l l Status bar The status bar contains the following information USB Radio indication Date label SSS USB Radio COM 10 May 14 2013 3 43 55 PM Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 5 Aperio Online User settings The User Settings on the Settings menu contains settings that are applicable to all installations Language Settings Select the application lanquage You will have to restart Aperio Programming Application Application Language Serial Port Settings Select how the USB Radio device shall be detected Automatically detect USB radio at startup USB Radio Port Communication port3 Refresh port list Advanced Settings Enable advanced device configuration in the configuration wizard If advanced device configuration is enabled it is possible to change radio channels and perform advanced lock and sensor configurations Show advanced settings Log Level Settings Log level TRACE v This feature should be used only for suppor pumoses Cancel Language settings Select the language used by the Pro
75. plication Manual Document No ST 001321 A Date 8 juli 2013 17 Aperio Online The configuration should look like this S Change DESFire configuration 7 Use DESFire RFID RFID Card Type DESFire w Application Id 1235 File Identity 2 File Start Position 0 Length to read in File 4 File Data Protection Level Full encryption Read Key Configuration Key Type AES 128 wij 0011223344556677889944BBC Key CDDEEFF Key Number 0 Low frequency SE Change Low frequency con Select low Frequency type fi HID Prox EM Prox Cancel In the list select the low frequency credential type to use HID Prox EM Prox i This credential type cannot be used together with any other credential types The following information is not applicable for US market Before the lock sensor has been configured with the Programming Application the lock sensor will accept any Low Frequency credential technology Once the lock has successfully read 3 times any credential technology the lock sensor will only accept this credential technology If the power is toggled the lock sensor will return to the initial state of accepting any credential Once a specific credential technology has been configured via the Programming Applica tion this will be the only accepted type of credential The lock will remain in this condition after the power has been toggled 18 Aperio Online Programming Application Manual Document
76. r the password supplied with the firmware L senord Ange l senord f r filen L senord eeeesees Result The firmware upgrade window is shown with a list of the units that may be upgraded Depending on the firmware file the list of firmware may vary Two examples are shown below gt Firmware Lock Main Application F Lock Main Application 6 1 19489 Firmware Version 6 1 19489 Lock UHF F Progress Information 23 18976 Not started Lock Secure Area s 2 6 18976 56 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 6 Click on Release Info to get more information about the selected afw file Aperio Yersion 2 6 1 Description Lock FW file for release 2 6 1 automatically generated for devices of type 2x_c100 mifareDesfire i Check in the release info window that the afw file used for upgrade is consistent with the lock cylinder type A C100 afw file must be used with cylinder locks An E100 afw file must be used with escutcheon locks etc 7 Close the Release Info window 8 Check that the new firmware version is higher than the firmware version currently loaded on the hardware Firmware Lock Main Application Lock Main Application 6 1 19489 Firmware Version 6 1 19489 Lock UHF Progress Information 2 3 18976 Not started Lock Secure Area y po oh
77. ssssssessesseeseeseeees 60 Installation of the Programming Application and USB radio dongle wu ecessessssssessesssesessesssesesseeseesseens 60 Updating the USB Radio ANN Yc acaceras csv ecsczag vas ees vepttaa cas nestsascedsuenay sevens teratvetdnlercctaes dewesstanseeestianeeecacus 70 Regulatory Information Regarding the Aperio USB Radio Dongle ccsesssseeseeseesees 76 OAV AUN Sos s5e heen A A E E A A 76 According to FCC15 247 en ne ene eee en een eer eern eee aera ee eee ee 76 According to FCE 15 105 by Information to the USET wiesscessasccasesecosccsscosesaceacea seosaasteaaseaseeacasaassssseuesensssstestoaseee 76 PO SMe IM NS i E E ace cnc decane fers cata aad A E EE E E N 16 Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online 1 Introduction Purpose The main purpose of this manual is to provide necessary information for a quick installation of Aperio Online based products using the Aperio Online Programming Application The manual is intended for installation personnel project managers and people with similar responsibilities Scope This manual includes a complete description of all functionality and possible settings in the Aperio Online Programming Application For quick installation instructions of a standard Aperio online system including communication hubs and locks sensors refer to ref 2 Aperio Online Quick Installation Guide This manual is applica
78. ult table Right click and select Lock sensor Change radio channels a o Programming Application File Scan Settings Help Lock sensor Communication Hub EAC Address UHF Link Communication Hub 024521 011C43 O216F1 i MAC Address 00 17 7a 01 02 Lock sensor 013542 Apply configuration gt zal Location Office A Communication Hub 024521 Configure are Flavor RS485 Multipl z Retrieve system information are Version 6 0 22795 Upgrade Firmware bader Version 1 2 5 Get Event Log Get Audit Trail protocol version 23 nel 11 2 405 GHz Change radio channels channels 11 16 25 Switch to Manufacturer Mode D 4521 Change physical location name addressing mode Legacy addre witch value 1 reviddress DIP Switch Remote open is activated Unpair lock sensor from communication hub Number of paired locks and sensors 3 Device Status EAC offline Lock sensor 013542 MAC Address 00 17 7a 01 02 Assigned Address 0x1230 EAC Address Radio protocol version 22 USB Radio COM 10 May 14 2013 12 53 29 PM 2 Uncheck any of the three currently used channels to be able to select other radio channels Click OK i For the US market channel 26 is disabled Aperio Online Programming Application Manual Document No ST 001322 A Date 8 juli 2013 Aperio Online Change radio channels in Communication Hub 024521 Atmostyou are able to set 3 separate radio ch
79. uration Allowed card types t least one card type must be selected v Prime ISO 15693 J 150 14443 amp Configuration type UID and data Segment search Search string hex 30030008 Segment type filter None Start segment 0 Data Use the first byte of the search string as address 0 for Advant Start address 0 Number of bytes 8 Checksum Type CRC amp bit Data start address 0 Data length 6 Checksum address 6 Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 Aperio Online 22 Segment 1 Search String 30 03 00 09 Segment type Access Data length 24 bytes Checksum 1 CRC 16 byte 0 10 Checksum 1 address 11 Checksum 2 CRC 16 byte 13 21 Checksum 2 address 22 Allowed card types At least one card type must be selected Prime 7 150 15693 Configuration type UID and data w Segment search Search string hex 30030009 Segment type filter None Start segment o Data Use the first byte of the search string as address 0 for Advant Start address 0 Number of bytes 24 Checksum Type CRC 16 bit Data start address 13 Data length 9 Checksum address 22 SS Gea i Only one checksum can be selected To include the search string in the first data byte check the Use the first byte of the searc
80. witches for EAC addressing always check that the DIP switch is set to the correct EAC ad dress If DIP 5 is active by mistake an upgrade will result in the communication hub starting to use another EAC address Upgrading 1 Ensure that you are using the latest version of the Aperio Programming Application If not install the latest version 2 Check on the UHF Link indicator that the signal strength indicator is good enough to be able to perform an upgrade green or yellow If you have bad signal strength red the Programming Application will not enable the upgrade function UHF Link Aperio Online Programming Application Manual Document No ST 001321 A Date 8 juli 2013 55 Aperio Online 3 Right click on the communication hub lock sensor in the Installation view and select Upgrade Firmware File Scan Settings Help Communication Hub 024521 gt f Upgrade Firmware 4 Select the firmware file afw fw file and click Open Look in id 4perio firmware i Aperio2 _c100_mifareDesfire 2 6 4 1344 afw z O Aperio2_cl00_mifarePlus 2 6 4 1344 afw __ Aperio2_LF_SDR 3 09 afw O Aperio2_p100_LF_SDR 2 6 4 1199 afw O build_c100_aperio2_mifarePlus 8 1 22357 afw Tidigare Skrivbord Mina dokument ke Dator ei File name Aperio2_c100_mifareDesfire 2 6 4 1344 afw open N tverk f Files of type Aperio Firmware File aFw Fw 7 5 Ente