Home
USER MANUAL
Contents
1. Run desinfection Press amp hold until LED color ring is flashing RED Release knob immediately Flashing RED Flushing with hot water Stop desinfection Press 1x or wait 5 minutes automatic stop Factory setting Press amp hold until LED color ring is flashing BLUE Release knob immediately Flashing 2x BLUE Factory setting restored Functions are depending on the TwinLevel controller used TLI Wheel Remote Wheel for shower application with temperature sensor Basic functions Water ON Press 1x Water ON Changing water temperature Turn when water ON Change temperature according LED color ring blue cold red hot Changing water flow Press hold and turn when water ON Change water flow Water OFF Press 1x Water OFF Quick Access for shower factory setting Quick Access 1 Quick Access 2 Quick Access 3 Press 1x Water ON by Press 2x briefly Water ON Press 3x briefly Water ON 36 Celsius and 80 by 37 Celsius and 80 by 38 Celsius and 80 water flow water flow water flow Saving Quick Access Quick Access 1 Quick Access 2 Quick Access 3 Press 1x Water ON like Press 2x briefly Water ON Press 3x briefly Water ON Quick Access 1 like Quick Access 2 Like Quick Access 3 Turn Change water temperature Press amp hold and turn Change water flow Press amp hold until LED color ring is flashing PURPLE Release knob immediately Flashing 2x PURPLE Water OFF
2. OBLAMATIK USER MANUAL TWINLEVEL INTERFACE Wheel INTERFACE for washbasin and shower Wheel Remote Wheel with TLC Temperature for kitchen washbasin shower bath WONO Disclaimer This manual was created with great care Oblamatik AG shall not be liable for technical or typographical errors and reserves the right to make changes to the product and or the instructions at any time without notice Oblamatik is not liable or responsible for direct or indirect damages which is in connection with the installation or operation of this product Imprint This manual is a publication of Oblamatik AG Gaeuggelistrasse 7 CH 7000 Chur SWITZERLAND All rights including translation are reserved Reproduction by any method for example photocopies or electronic recording are not allowed Reproduction in full or partly is prohibited These instructions represent the technical status at time of printing 6 The user manual must be given to the user Please read this user manual carefully before using the system and keep in a safe place for future reference To reduce the risk of injuries scalding and electrical shock the safety precautions below must be instal led and followed Risk of injury This device is not intended for use by persons with different or reduced physical sensory or mental abi lities or who lack experience or knowledge unless they are under the supervision of or receive training for the u
3. 1x and adjust desired interval flushing Flashing 2x YELLOW Setting is saved Flashing 1 x 1 Day Flashing 2 x 2 Days Flashing 3 x 3 Days Flashing 4 x 7 Days Flashing 5 x inactive Menu From here on are the functions at factory settings adjustab le for 1 hour after Initiation Press amp hold for 3 sec Popup Press amp hold for 3 sec Cleaning mode Press amp hold for 3 sec Press amp hold for 3 sec Diagnostic Press amp hold for 3 sec max Temperature Press amp hold for 3 sec Thermal disinfection Press amp hold for 3 sec Factory setting Press amp hold for 3 sec Press amp hold for 3 sec Maximal water flow time Press amp hold for 3 sec Ambient Light turn flashing flashing color flashing confirm confirm confirm confirm TLI Wheel Remote Wheel for kitchen and washbasin application VO Basic functions Water ON Press 1x Water ON Changing water temperature Turn when water ON Change temperature according LED color ring blue cold red hot Changing water flow Press hold and turn when water ON Change water flow Water OFF Press 1x Water OFF Quick Access for kitchen washbasin factory setting Quick Access 1 Quick Access 2 Quick Access 3 Press 1x Water ON cold Press 2x briefly Water ON Press 3x briefly Water ON water and 80 water flow warm water and 80 hot water and 80 w
4. Flashing 3x ORANGE Malfunction of the temperatur sensors Contact Support Center Troubleshooting if LED color ring is NOT illuminating Please check the cable connection between TLC Controller and Interface If you were unable to resolve the issue please contact Support Center Remote Wheel Press amp hold TLI Wheel until LED color ring is flashing PINK Release knob immediately Press the Remote Wheel 1 x briefly Flashing PINK Connection to the radio modul is done Special functions Press amp hold until LED color ring is flashing TURQUOISE Release knob immediately Flashing 1x TURQUOISE Special functions activated Flashing 2x TURQUOISE Special functions locked Changing between activation locking device press amp hold until LED color ring is flashing TURQUOISE Release knob immediately Thermal desinfection A ATTENTION RISK OF SCALDING Run desinfection Press amp hold until LED color ring is flashing RED Release knob immediately Flashing RED Flushing with hot water Stop desinfection Press 1x or wait 5 minutes automatic stop Factory setting Press amp hold until LED color ring is flashing BLUE Release knob immediately Flashing 2x BLUE Factory setting restored Functions are depending on the TwinLevel controller used Quick Access for bath factory setting Quick Access 1 Quick Access 2 Quick Access 3 Press 1x Water ON by Press 2x briefly Water ON P
5. connected Oblamatik AG G uggelistrasse 7 CH 7000 Chur ale ee Ovo info Qoblamatik ch oblamatik ch 222701 03 15
6. setting is saved Scalding protection Turn Changing temperature From 38 C temperature increase in smaller increments more wheel turns Diverting fixed head handshower Press 1x Water ON Press amp hold until LED Color ring Is flashing LIGHT BLUE Release knob immediately Diverting fixed head lt gt handshower Activating the cleaning mode Deactivate Interface Press amp hold until LED color ring is flashing GREEN Release knob immediately Reactivate Interface Press amp hold until LED color ring GREEN goes out or wait 45 seconds automatic reactivation Press amp hold until LED color ring is flashing ORANGE Release knob immediately Start Diagnostic 1 LED color ring is illuminating RED Check if hot water flows No warm water is flowing Check the hot water supply line Is hot water supply line open Is hot water system activated Is mesh filter ok Are cold and warm water supply lines correctly connected 2 LED color ring is illuminating GREEN Check if NO water flows Water flows Device is broken contact Support Center 3 LED color ring is illuminating BLUE Check if cold water flows No cold water is flowing Check cold water supply line Is cold water stop valve opened Is mesh filter ok Are cold and warm water supply lines correctly connected Diagnostic completed Flashing 2x ORANGE Diagnostic successfully completed
7. 1 LED color ring is illuminating RED Press 1x Water ON Press 1x Water OFF Check if hot water flows Reactivate Interface Changing water temperature No warm water is flowing Check the hot water supply line Is hot water supply line open Is hot water system activated Is mesh filter ok Are cold and warm water supply lines correctly connected Press amp hold until LED color ring GREEN goes out or wait 45 seconds Turn when water ON Change temperature automatic reactivation according LED color ring blue cold red hot 2 LED color ring is illuminating GREEN Check if NO water flows Water flows Device is broken contact Support Center 3 LED color ring is illuminating BLUE Check if cold water flows No cold water is flowing Explanation of special functions These functions at factory settings are adjustable for 1 hour after initiation If this does not happen unplug the controller and restart after 5 min Thermal desinfection Maximal water flow time Press amp hold until LED color ring is flashing PINK Release knob immediately Press 1x and adjust disered water flow time Flashing 2x PINK Setting is saved Color setting of the LED color ring Press amp hold until LED color ring is flashing LIGHT BLUE Release knob immediately Press 1x and choose desired color Flashing 2x LIGHT BLUE Setting is saved Available colors Check cold water su
8. EN Turn when water ON Change temperature Check if NO water flows according LED color ring blue cold red hot Water flows Device is broken contact Support Center 3 LED color ring is illuminating BLUE Check if cold water flows No cold water is flowing Check cold water supply line Is cold water stop valve opened Is mesh filter ok Are cold and warm water supply lines correctly connected Diagnostic completed Flashing 2x ORANGE Diagnostic successfully completed Flashing 3x ORANGE Malfunction of the temperatur sensors Contact Support Center Troubleshooting if LED color ring is NOT illuminating Please check the cable connection between TLC Controller and Interface If you were unable to resolve the issue please contact Support Center Temperature limitation Press amp hold until LED color ring is flashing WHITE Release knob immediately Water ON LED color ring is flashing WHITE Turn adjust desired maximum temperature Press 1x Temperature will be save as maximum Temperature Flashing 2x WHITE Setting is saved Explanation of special functions These functions at factory settings are adjustable for 1 hour after initiation If this does not happen unplug the controller and restart after 5 min Thermal desinfection A ATTENTION RISK OF SCALDING Run desinfection Press amp hold until LED color ring Is flashing RED Release knob immediately Flash
9. Saving Quick Access Quick Access 1 Quick Access 2 Quick Access 3 Press 1x Water ON like Press 2x briefly Water ON Press 3x briefly Water ON Quick Access 1 like Quick Access 2 Like Quick Access 3 Turn Change water temperature Press amp hold until LED color ring is flashing PURPLE Release knob immediately Flashing 2x PURPLE Water OFF setting is saved Maximum Quick Access temperature is 38 Celsius scalding protection temperature TLI Wheel for shower application Scalding protection Diagnostic with TLC Temperature temperature sensor J Turn Changing temperature Press amp hold until LED color ring Is flashing From 38 C temperature increase in smaller ORANGE Release knob immediately increments more wheel turns Start Diagnostic 1 LED color ring is illuminating RED Check if hot water flows Activating the cleaning mode Basic functions Deactivate Interface No warm water is flowing Check the hot water supply line Water ON Water OFF Press amp hold until LED color ring is Is hot water supply line open flashing GREEN Release knob immediately Is hot water system activated Is mesh filter ok Are cold and warm water supply lines Reactivate Interface correctly connected Press 1x Water ON Press 1x Water OFF Changing water temperature Press amp hold until LED color ring GREEN goes out or wait 45 seconds automatic reactivation 2 LED color ring is illuminating GRE
10. ater flow water flow Saving Quick Access Quick Access 1 Quick Access 2 Quick Access 3 Press 1x Water ON like Press 2x briefly Water ON Press 3x briefly Water ON Quick Access 1 like Quick Access 2 Like Quick Access 3 Turn Change water temperature Press amp hold and turn Change water flow Press amp hold until LED color ring Is flashing PURPLE Release knob immediately Flashing 2x PURPLE Water OFF setting is saved Activating the cleaning mode Turn Changing temperature Deactivate Interface From 38 C temperature increase in smaller increments more wheel turns Scalding protection Press amp hold until LED color ring is flashing GREEN Release knob immediately Pop up open close Reactivate Interface Press amp hold until LED color ring is flashing LIGHT BLUE Release knob immediately Press amp hold until LED color ring GREEN Pop up open or close goes out or wait 45 seconds automatic reactivation Press amp hold until LED color ring is flashing ORANGE Release knob immediately Start Diagnostic 1 LED color ring is illuminating RED Check if hot water flows No warm water is flowing Check the hot water supply line Is hot water supply line open Is hot water system activated Is mesh filter ok Are cold and warm water supply lines correctly connected 2 LED color ring is illuminating GREEN Check if NO water flows Water flows Device is broken contact Su
11. care Wipe with a dry cloth Avoid the use of abrasives or solvents which damage the surface Damage caused by inappropriate treatment by the user is not covered by our guarantee Quick Access for washbasin factory setting Quick Access 1 Quick Access 2 Quick Access 3 Press 1x Water ON Press 2x briefly Water ON Press 3x briefly Water ON by 12 Celsius by 30 Celsius by 40 Celsius Saving Quick Access Quick Access 1 Quick Access 2 Quick Access 3 Press 1x Water ON like Press 2x briefly Water ON Press 3x briefly Water ON Quick Access 1 like Quick Access 2 Like Quick Access 3 Turn Change water temperature Press amp hold until LED color ring is flashing PURPLE Release knob immediately Flashing 2x PURPLE Water OFF setting is saved 0 Maximum Quick Access temperature is 38 Celsius scalding protection temperature TLI Wheel for washbasin application Pop up open close Scalding protection with TLC Temperature temperature sensor Press amp hold until LED color ring is Turn Changing temperature flashing LIGHT BLUE Release knob From 38 C temperature increase in smaller immediately Pop up open or close increments more wheel turns Activating the cleaning mode Diagnostic 3 Deactivate Interface Press amp hold until LED color ring is flashing Basic functions ORANGE Release knob immediately rear aE Press amp hold until LED color ring is AR DIRE flashing GREEN Release knob immediately
12. color ring is flashing GREEN until Flashing 2x YELLOW Setting is saved Interface will be pressed 1x Press amp hold until LED color ring is flashing ee i a WHITE Release knob immediately actory settin Water ON LED color ring is flashing WHITE M 9 as l ae Flashing 5 x inactive Turn adjust desired maximum temperature Press amp hold until LED color ring is flashing BLUE Release knob immediately Press 1x Temperature will be save as Flashing 2x BLUE Factory setting restored maximum Temperature Flashing 2x WHITE Setting is saved Menu From here on are the functions at factory settings adjustab le for 1 hour after Initiation Press amp hold for 3 sec Popup Press amp hold for 3 sec Cleaning mode Press amp hold for 3 sec Press amp hold for 3 sec Diagnostic Press amp hold for 3 sec max Temperature Press amp hold for 3 sec Thermal disinfection Press amp hold for 3 sec Factory setting Press amp hold for 3 sec Press amp hold for 3 sec Maximal water flow time Press amp hold for 3 sec Ambient Light turn flashing flashing color flashing confirm confirm confirm confirm Quick Access for shower factory setting Quick Access 1 Quick Access 2 Quick Access 3 Press 1x Water ON Press 2x briefly Water ON Press 3x briefly Water ON by 36 Celsius by 37 Celsius by 38 Celsius
13. g 2x DARK BLUE Water OFF reset settings filling quantity is deactivated temperature Turn when water ON Change temperature and water flow like factory setting according LED color ring Press 1x Water OFF blue cold red hot Water OFF Diverting tub hand headshower aana a Remote Wheel Thermal desinfection Check if NO water flows Kas E nar ON n PEETA Press amp hold TLI Wheel until LED color ring A ATTENTION RISK OF SCALDING ss amp hold until LED Color ring is flashing is flashing PINK Release knob immediately ice k tact t ter LIGHT BLUE Release knob immediately Device is broken contact Support Center Press the Remote Wheel 1x briefly Diverting fixed head lt gt handshower Run desinfection 3 LED color ring is illuminating BLUE Flashing PINK Connection to the radio Check if cold water flows modul is done Press amp hold until LED color ring is flashing Scalding protection RED Release knob immediately No cold water is flowing EP eee NK teins Special functions Flashing RED Flushing with hot water From 38 C temperature increase in smaller Is cold water stop valve opened increments more wheel turns Is mesh filter ok Press amp hold until LED color ring is flashing Stop desinfection Are cold and warm water supply lines TURQUOISE Release knob immediately correctly connected l i Activating the cleaning mode Flashing 1x TURQUOISE Pa a aa ete Special functions ac
14. ing RED Flushing with hot water Stop desinfection Press 1x or wait 5 minutes automatic stop Q In case the temperature does not reach 70 Celsius within 2 minutes water flow will stop and LED color ring is flashing RED until Interface will be pressed 1x During the thermal disinfection the temperature must be consistently gt 70 Celsius over 3 minutes of time After completion the LED color ring is flashing GREEN until Interface will be pressed 1x Factory setting Press amp hold until LED color ring is flashing BLUE Release knob immediately Flashing 2x BLUE Factory setting restored Maximal water flow time Color setting of the LED color ring Press amp hold until LED color ring is flashing PINK Release knob immediately Press amp hold until LED color ring is flashing LIGHT BLUE Release knob immediately Press 1x and adjust disered water Press 1x and choose desired color flow time Flashing 2x LIGHT BLUE Setting is saved Flashing 2x PINK Setting is saved Available colors Flashing 1 x 5 sec Flashing 2 x 8 sec Flashing 3 x 10 sec Flashing 4 x 15 sec Flashing 95 x 20 sec Flashing 6 x 30 sec Flashing 7 x 45 min Flashing 8 x 1 min Flashing x 5 min Flashing 10 x 15 min Flashing 11 x 30 min Flashing 12 x open Hygienic flushing Press amp hold until LED color ring is flushing YELLOW Release knob immediately Functions are depending on the TwinLevel controller used Press
15. pply line l i Flashing 1 x 5 sec Is cold water stop valve opened ATTENTION RISK OF SCALDING Flashing 2 x 8 sec Is mesh filter ok Flashing 3 x 10 sec Are cold and warm water supply lines Run desinfection Flashing 4 x 15 sec correctly connected Flashing 5 x 20 sec che TK Press amp hold until LED color ring is flashing Ka ne 9 RED Release knob immediately ng Diagnostic successfully Flashing 8 x 1 min completed Flashing 9 x 5 min Flashing 3x ORANGE Flashing RED Flushing with hot water Placing i 15 min Malfunction of the temperatur sensors Flashing 11 x 30 min Contact Support Center Stop desinfection Flashing 12 x open Troubleshooting if LED color ring is NOT oe Press 1x or wait 5 minutes automatic stop illuminating Hygienic flushing i In case the temperature does not reach 70 Please check the cable connection between Celsius within 2 minutes water flow will stop TLC Controller and Interface If you were unable to resolve the issue please contact Support Center Temperature limitation Press amp hold until LED color ring is flushing YELLOW Release knob immediately Functions are depending on the TwinLevel controller used and LED color ring is flashing RED until Interface will be pressed 1x Press 1x and adjust desired interval flushing During the thermal disinfection the temperature must be consistently gt 70 Celsius over 3 minutes of time After completion the LED
16. pport Center 3 LED color ring is illuminating BLUE Check if cold water flows No cold water is flowing Check cold water supply line Is cold water stop valve opened Is mesh filter ok Are cold and warm water supply lines correctly connected Flashing 2x ORANGE Diagnostic successfully completed Troubleshooting if LED color ring is NOT illuminating Please check the cable connection between TLC Controller and Interface If you were unable to resolve the issue please contact Support Center Press amp hold TLI Wheel until LED color ring is flashing PINK Release knob immediately Press the Remote Wheel 1 x briefly Flashing PINK Connection to the radio modul is done Special functions Press amp hold until LED color ring is flashing TURQUOISE Release knob immediately Flashing 1x TURQUOISE Special functions activated Flashing 2x TURQUOISE Special functions locked Changing between activation locking device press amp hold until LED color ring is flashing TURQUOISE Release knob immediately Temperature limitation Special function must be activated Press amp hold until LED color ring is flashing WHITE Release knob immediately Water ON LED color ring is flashing WHITE Turn adjust desired maximum temperature Press 1x Temperature will be save as maximum Temperature Flashing 2x WHITE Setting is saved Thermal desinfection A ATTENTION RISK OF SCALDING
17. ress 3x briefly Water ON 36 Celsius and 100 by 37 Celsius and 100 by 38 Celsius and 100 water flow water flow water flow Saving Quick Access Quick Access 1 Quick Access 2 Quick Access 3 Press 1x water ON tempe Press 2x briefly water ON Press 3x briefly water ON rature and water flow Quick temperature and water flow temperature and water flow Access 1 like Quick Access 2 like Quick Access 3 Start tub filling measurement 10 liters of water will be filled in automatically Turn Change water temperature TLI Wheel Remote Wheel for bath application Press amp hold and turn Change water flow with temperature and water flow sensor Fill in desired water quantity Press amp hold until LED color ring Is flashing PURPLE Release knob immediately Flashing 2x PURPLE Water OFF setting is saved average temperature water flow and filling quantity which was last set Reset Quick Access Special function must be activated Basic functions Quick Access 1 Quick Access 2 Quick Access 3 Water ON Changing water flow Press 1x water ON tempe Press 2x briefly water ON Press 3x briefly water ON Press 1x Water ON Press hold and turn when water ON Change rature and water flow Quick temperature and water flow temperature and water flow water flow Access 1 like Quick Access 2 like like Quick Access 3 Siang nga sn pe naun Press amp hold until LED color ring is flashing DARK BLUE Release knob immediately Flashin
18. se of the device by a person responsible for their safety CONTINUOUSLY TURNING THE CONTROL WHEEL IN THE CLOCKWISE DIRECTION MAY OVERRIDE THE PRE SET MAXIMUM TEMPERATURE RESULTING IN A RISK OF SCALDING If the power cord gets damaged it must be replaced by the manufacturer its authorized service agent or qualified personnel to avoid danger Never operate the device with a damaged cable or plug Do not pull on the power cable as this could cause damage to the cable and cause electric shock Malfunctions Possible cause Solution The device is not working Start Diagnostic Check that The control unit is connected to the mains There is no power supply failure The electric plug inside the control unit is well connected No water flow when activated Check that Your faucet is connected to the water supply Both angle valves are fully opened Check another faucet in the house if water is running The water supply hoses are not bent or twisted The supply hoses might be soiled The control unit is connected to the mains Minimal water flow Check that Both angle valves are fully opened The water supply hoses are not bent or twisted The supply hoses might be soiled Continuous water flow Press the ON OFF button Close angle valve or main valve After a few minutes open again It s still a continuous water flow close valve and contact your installer Use soft cloth soapy solution and water for regular
19. tivated Diagnostic completed Factory setting Deactivate Interface Flashing 2x ORANGE Flashing 2x TURQUOISE Diagnostic successfully Special functions locked Press amp hold until LED color ring is completed Press amp hold until LED color ring is flashing flashing GREEN Release knob immediately Changing between activation locking device BLUE Release knob immediately Flashing 3x ORANGE press amp hold until LED color ring is flashing Malfunction of the temperatur sensors TURQUOISE Release knob immediately Flashing 2x BLUE Factory setting restored Reactivate Interface Contact Support Center Functions are depending on the TwinLevel controller used Press amp hold until LED color ring GREEN Flashing 4x ORANGE goes out or wait 45 seconds Malfunction of the flow rate sensors Contact automatic reactivation Support Center Troubleshooting if LED color ring is NOT Diagnostic P E illuminating Press amp hold until LED color ring is flashing ORANGE Release knob immediately Start Diagnostic Please check the cable connection between TLC Controller and Interface If you were unable to resolve the issue please contact Support Center 1 LED color ring is illuminating RED Check if hot water flows No warm water is flowing Check the hot water supply line Is hot water supply line open Is hot water system activated Is mesh filter ok Are cold and warm water supply lines correctly