Home
Installation and User Guide iDIM Remote Control (304
Contents
1. Installation and User Guide Helvar iDIM Remote Control 304 freedom in lighting Product description C The iDim Remote Control 304 can be used with the iDim Sense Standalone to modify the preset light levels and recall store scenes as well as to activate special functions 100 h Burn In PIR Walk test and Mode Identification Combined with iDim Studio the 304 iDim Remote can provide further advanced configuration Please see document Dim Studio Help or iDim User Manual D004735 for further information Note Throughout this document Controller refers to iDim Sense and or DIGIDIM Button Panels A LED indicator Flashes when comms D OK key l Mode selection button e in progress and when outtons E 1 4 Scene Recall Configuration J Battery cover F Function key Fn K USB connection Mini B B Up modifier G Lights off Id C Down modifier H Transmitter Helvar Data is subject to change without notice www helvar com i I Contents Section Product description Add Remove Batteries Assemble iDim Remote Cradle for Desktop Use Setup 1Dim Remote Cradle for Wall Attachment Attach iDim Remote to Cradle Connecting the iDim Remote to your PC Switching Lights On Recall Scenes using iDim Remote Modify Light Levels using iDim Remote Modify Light Levels using iDim Remote Stores Scenes using iDim Remote Special Functions using iDim Remote Special Fun
2. Point the remote at a controller 2 Press key on remote control to switch the lights off When lights are switched off via a remote switch or panel a 90 second exit delay will start During this time any PIR movement will extend the delay The exit delay will be cancelled when a new scene is manually selected Modify Light Levels using iDim Remote DALI 1 and DALI 2 scenes operate as a combination of Constant Light CL Fixed Light FL and Offset dependent on which of the 6 iDim modes that an iDim Sense is in and the scene selected It is possible to modify the DALI 1 and DALI 2 levels using the iDim Remote The adjusted levels will only be temporary unless they are stored Into the already selected scene For example e If DALI 1 1s a Constant Light Scene then modifying the levels will cause the Constant Light target level to be modified e f DALI 1 is a Fixed Light scene then the Fixed Light level will be modified e If operating in Constant Light Offset mode the DALI 2 level will also be affected if DALI1 is modified Please refer to table 1 overleaf for default DALI 1 and 2 scene setup for each iDim mode Other advanced configuration such as configuring the bright out level is only possible using the iDim Studio software Helvar 304 iDIM Remote Control Installation and User Guide Doc 7860263 issue 5 2014 08 28 3 Modify Light Levels using iDim Remote Freedom in lighting When modifying the cons
3. locked the iDim Sense mode selector ring can still be manually turned However the modes will be ignored unless the mode selector ring is unlocked Unlock iDim Sense Mode Selector Ring IDim Sense LED flash feedback To unlock the mode selector ring of an IDim Sense 00 iP Ensure the Dim Remote Is In special function mode z5 gt Ay t 2 Point the remote at the iDim Sense you wish to unlock e 3 Press and hold DALI 2 modifier down and Fn key at the 10s same time for 10 seconds Note iDim Sense will remain in the selected mode and in user defined mode where applicable until the mode selector ring is turned again Advanced Configuration with iDim Studio Software Note All standard operation settings such as scene recall modify and store scene are still possible when the iDim Remote is in Special function mode Transfer settings to iDim Sense using iDimRemote To transfer settings to iDim Sense using iDim Remote 1 Ensure the Dim Remote Is in special function mode Z Point the remote at a controller 3 Press OK and Fn key at same time 6 Helvar 304 iDIM Remote Control Installation and User Guide Doc 7860263 issue 5 2014 08 28 Helvar iDim Sense LED Flash Feedback freedom in lighting Two LEDs red and green in the Dim Sense flash to provide visual feedback for various states and operations User defined mode selected C ae Ge Ge G amp G GC C C6 esting Room medel Ge Ge G G Ge G
4. stores will only activate green scene store LED Example for mode 2 To exit User Defined mode and reset the iDim Sense to default Single Office Mode mode settings the iDim Remote Control must be in special function mode Please see chapter below for more information Special Functions using iDim Remote It is possible to make the iDim Remote perform advanced tasks to assist commissioning and system testing The iDim Remote uses a special function mode where these advanced tasks can be configured This mode must be activated before a special function or test is run This avoids accidental configuration changes or tests being run which could cause the light levels or scenes to be altered unintentionally Please see below for activating and deactivating special function mode See pages 7 8 for the types of special functions possible To activate special function mode 1 Remove the battery cover from the remote control rd Using a pen or other long blunt object press mode 3 seconds o selector button on the reverse of the iDim Remote 92 OE Py aay for 3 seconds Special function mode is now active gt Check that the iDim Remote is in special function mode by recalling a scene The Dim Remote LED will flash orange when a function i e Scene recall Is performed 4 Run the special functions that you require See pages 7 and 8 for special functions When a remote key is pressed during standard operation i
5. the 100 hour Burn in time to be reset Use Resume Burn In Mode to continue a stopped Burn In test Resume Burn In Mode IDim Sense LED flash feedback To resume a stopped Burn In mode 1 Ensure the iDim Remote is in special function mode rA Point the remote at a controller d Press Fn key and scene 2 at the same time Lights blink 4 times and go to 100 if Burn In counter is not at Zero Note If a Power Off On cycle occurs the Burn In time will be reset to 100 hours Mode Identification IDim Sense LED flash feedback To establish which iDim mode Is selected OO 1 Ensure the Dim Remote Is in special function mode HC 5 gt j P If Mode 1 has not been 2 Point the remote at a controller w modio J Press Fn key and scene 3 at the same time Fiod Tiei iDim Sense LEDs will flash the current mode D User Defined mode Note Number and type of flashes depends on mode selected and if the iDim Sense is in User Defined mode Start Stop PIR Walk Test IDim Sense LED flash feedback To start stop PIR Walk test OO 1 Ensure the iDim Remote is in special function mode gt 2 Point the remote at a controller 2 oF Press Fn key and scene 4 at the same time iDim Sense will flash then wait for 10 s before looking for movement When movement is detected lights will go on for 5 s to transition level for 3 s off for 5 s and then return to the currently selected mode Reset Mode ba Note To reset a contr
6. Dim Remote LED flashes green Note 1 All standard operation settings such as scene recall modify and store scene are still possible when the iDim Remote Is in special function mode Note 2 Once special function mode Is activated it will remain so until it is manually deactivated When a remote key is pressed in special function mode IDim Remote LED flashes orange To deactivate special function mode 1 Hold the mode selector button for 1 second to return to standard operation Special function mode is now deactivated a Check that the iDim Remote is in standard operating mode by recalling a scene on the remote The iDim Remote LED should flash green when scene recall When the iDim Remote is communicating with a PC the iDim Remote LED flashes Is called red Do NOT disconnect during this time 4 Helvar 304 iDIM Remote Control Installation and User Guide Doc 7860263 issue 5 2014 08 28 Special Functions using iDim Remote cont freedom in lighting Start Stop 100 hour Burn In Mode IDim Sense LED flash feedbac To start or stop Burn In mode 0 0 1 Ensure the iDim Remote is in special function mode e gt j k Point the remote at a controller J Press Fn key and scene 1 at same time Lights will blink 4 times and then go to 100 The 100 hour Burn In counter will begin 4 To stop Burn In mode press Fn key and scene 1 Note Restarting a Burn In test following a stop will cause
7. adle To attach the iDim Remote to the remote cradle 1 2 Note Place iIDim Remote onto cradle mounting point Push iDim Remote downwards until it clicks holding the unit in place Remove the iDim remote by following the above procedure In reverse 1 Helvar 304 iDIM Remote Control Installation and User Guide Freedom in lighting Doc 7860263 issue 5 2014 08 28 Connecting the iDim Remote to your PC Freedom in lighting Note 1 The Dim Remote only needs to be connected to a PC if you want to set advanced configuration settings via your PC The remote will work without iDim Studio Note 2 To download iDim Studio please visit www helvar com To connect the iDim Remote to your PC 1 Attach Mini USB connector to iDim remote 2 2 Connect the opposite end of the USB cable to the USB port of the PC The new device will be automatically recognised 3 Run iDim Studio if installed Do NOT disconnect iDim Remote when the LED is flashing red While using iDim Studio software the iDim Remote LED flashes red when device communication Is in progress Do not disconnect the iDim Remote from PC during this time Switching Lights On Recall Scenes using iDim Remote To switch lights on recall a scene using the iDim remote 1 Point the remote at a controller Point the remote at a controller 2 Press scene key 1 2 3 or 4 to recall the required scene To switch lights off 9
8. ctions using iDim Remote cont Special Functions using iDim Remote iDim Sense LED Flash Feedback Technical Data Helvar Data is subject to change without notice Page CON Oo oF FF WN NN FP FF gt freedom in lighting www helvar com Add Remove Batteries To add or remove batteries i Note Assemble iDim Remote Cradle for Desktop Use Unclip the battery cover on the reverse of the remote Add batteries observing correct polarity and replace cover Batteries not required if running iDim Remote Control through a PC via USB cable To assemble the iDim Remote Cradle for desktop use 3 ae Attach rubber feet A to base B Insert base B into recess C on the reverse of the cradle until It clicks To disassemble the iDim Remote Cradle not shown Setup iDim Remote Cradle for Wall Attachment Insert flat head screwdriver into recess C and gently lever base A away from the cradle to avoid the unit being damaged To mount the iDim Remote Cradle to a wall te Drill and insert screw to chosen mounting location Leave approx 1 mm between screw head and wall to allow cradle to sit comfortably on screw Carefully slide the cradle onto the screw adjusting screw tightness as required With cradle still wall mounted mark hole A on the wall Remove cradle drill second hole and apply wall plug Slide cradle back on to wall and insert bottom screw Tighten screw as needed Attach iDim Remote to Cr
9. e PIR Walk Test Mode Sequence repeats until walk test is complete LED flash feedback Mode unmodified default mode Mode 1 Selected Classroom mode Mode 2 Selected Single Office mode Mode 3 Selected Open Plan mode Mode 4 Selected Corridor Link mode Mode 5 Selected Corridor Hold mode 100 hour Burn In Mode Sequence repeats until burn in is complete 30 seconds 30 seconds m DALI Errors Sequence repeats until error clears Change from unoccupied to occupied Typically follows a PIR detection Data received from IR Remote D Successful Scene Store Failed Scene Store Successful Upload from IR Remote Failed Upload from IR Remote Note iDim Sense LED feedback flashes apply to all iDim units of v5 3 and onwards To leave User Defined mode and reset iDim Sense to default settings at any time hold button 3 4 on the iDim Remote Control for 10 seconds while the remote is in Special function mode See page 6 8 for information Helvar 304 iDIM Remote Control Installation and User Guide Doc 7860263 issue 5 2014 08 28 8 Technical Data Connections PC to remote USB 2 0 A Cable to Mini B Cable Power Power supply 2 x AAA LRO3 1 5 V batteries Range Operating range Approx 10 m Operating frequency 36 kHz Remote control functions Infrared remote control Modify preset light levels Constant light or fix
10. ed light Scene store and recall Activate special test functions Mechanical data Dimensions 99 mm x 21 mm x 110 mm Material housing Non flammable polycarbonate halogen free Colour housing Traffic White RAL 9016 Weight 40g Bracket screws 2 x No 6 3 5 mm x 20 mm pan pozi head screws Operating conditions Ambient temperature 0 C to 40 C Relative humidity Max 90 non condensing Storage temperature 10 C to 70 C Conformity and standards EMC emission EN 61000 6 3 EMC immunity EN 61006 1 Safety EN 60950 1 Environment Complies with WEEE and RoHS directives Helvar 304 iDIM Remote Control Installation and User Guide Freedom in lighting Doc 7860263 issue 5 2014 08 28
11. oller to factory default settings M4 k oe ae i t The active mode flashes ll Ensure the Dim Remote is in special function mode LA a a Point the remote at a controller Os J 10s eee net oe 3 Press and hold key 3 and 4 at same time for 10 s selected Note Lights will behave in the same manner as when B powered up for the first time in the mode currently selected 5 Helvar 304 iDIM Remote Control Installation and User Guide Doc 7860263 issue 5 2014 08 28 Special Functions using iDim Remote freedom in lighting Enable IR Receiver IDim Sense LED flash feedback To enable the Infrared receiver of a controller 0 0 iF Ensure the Dim Remote Is in special function mode 2 Point the remote at a controller oF Press and hold DALI 1 modifier up and Fn key at the same time for 10 seconds Disable IR Receiver IDim Sense LED flash feedback To disable the Infrared receiver of a controller 0 0 1 Ensure the Dim Remote Is in special function mode 2 Point the remote at a controller 2 Press and hold DALI 1 modifier down and Fn key at the same time for 10 seconds Lock iDim Sense Mode Selector Ring IDim Sense LED flash feedback To lock the mode selector ring of an iDim Sense 00 1 Ensure the IiDim Remote is in special function mode gt gt Q T 2 Point the remote at the iDim Sense you wish to lock gt 3 Press and hold DALI 2 modifier up and Fn key at the 10s same time for 10 seconds Note When
12. oom switching off SW1 will cause both DALI 1 and DALI 2 circuits to go off To modify light levels using the iDim remote 1 Point the remote at a controller 2 Select the scene that you want to modify 3 Press DALI 1 modifier key up to raise DALI 1 light level 4 Press DALI 1 modifier key down to lower DALI 1 light level ie 42 g Press DALI 2 modifier key up to raise DALI 2 light level 6 Press DALI 2 modifier key down to lower DALI 2 light level DALI 1 gt 100 Note 1 Ifyou intend to store the modified levels ensure that the required scene number Is selected before modifying ay 100 gt 19 0 Note 2 Scene 1 is the default on scene selected by PIR movement and Solo SW1 and SW2 Note 3 When operating in Constant light Offset mode the DALI 1 and DALI 2 levels will both adjust together Helvar 304 iDIM Remote Control Installation and User Guide Doc 7860263 issue 5 2014 08 28 Stores Scenes using iDim Remote freedom in lighting To store a modified scene using the iDim remote IDim Sense LED flash feedback i Point the remote at a controller PA Hold scene key 1 2 3 or 4 for 10 seconds to store scene iDim Sense LEDs will flash green if scene successfully stored The iDim mode will then flash the iDim mode number red green to signify that the iDim Sense is in User Defined mode Note Mode flash will only occur when storing scenes for the first time Further scenes
13. tant light target levels for your system please ensure that the process Is done in a darkened room or during dusk as excessive natural light may result In levels being recorded by the sensor that are not actually achievable Table 1 Default DALI 1 and DALI 2 Constant Light Fixed Light and Offset configuration for the six default iDim modes In this table iDim Controller refers to iDim Remote Switches and Panels unless specified 6 2 6 ee 6 m2 6 2 D 3 C s 3 D pS 5 D O 3 4 4 4 4 4 SINGLE OPEN PLAN CORRIDOR CORRIDOR MEETING CLASSROOM OFFICE OFFICE LINK HOLD ROOM DALI 1 CIL CIL CIL FL 100 GIL CL iDim Controller Coane Link to See notes DALI 2 Offset Offset Offset FL 100 corridor below DASE CL CL CIL FL 70 CL iDim Controller Link Ink to Scene 2 DALI 2 Offset Offset Offset FL 70 FL 100 corridor DALI 1 POO FL 100 FL 100 FL 40 FL 100 iDim Controller hate INK to scene 3 DALI 2 FL 100 FL 100 FL 100 FL 40 FL 0 corridor DALI 1 FL 40 FL 40 FL 40 EEO FL 40 FL 40 Din Controller Scene 4 Link to DALI 2 FL 40 FL 400 FL 40 FL 10 l FL 20 corridor Note 1 In Corridor Hold iDim Mode 5 DALI 2 is only used to connect an offi ce to the corridor Note 2 In Meeting Room iDim Mode 4 iDim Solo SW1 input operates DALI 1 CL Off and SW2 input operates DALI 2 FL 100 Off as SW1 is located at the entrance of a r