1. Span 10 F3 One press on this button decrease the span of the x axis with 10 ms Span 100 F2 One press on this button decrease the span of the x axis with 100 ms Navigation buttons With this set of buttons the user can navigate forward or backwards in the graph this is only possible when the measuring is stopped Scroll When this button is pressed the navigation buttons is activated To the beginning One press on this button shows the graph from the beginning Back One press on this button steps back in the graph window Forward One press on this button steps forward in the graph window One press this button shows the graph from the end Cursor buttons You can use the cursor function to make custom voltage or time measurements on scope signals dh Cursor This button lets the user select one of the following cursor functions X value X This cursor style displays the current x axis value ms y PSI Period This cursor style displays the value of the distance between the two displayed cursors when measuring two data points along the x axis ms Y Value Y This cursor style displays the current y axis value V EY Peak to peak This cursor style displays the value of the distance between the two displayed cursors when measuring two data points along the y axis V Hide Cursor This function hides the cursor Action buttons Defau
2. a curve makes it easier in high level the reference curve that is shown in this chapter Oscilloscope measure specification Measure choice Measure choice oss Seperate o Measure choice USB SerialcableRS232 Bluetooth Description Buttons Measure buttons With this set of buttons the user can start and stop the measuring Play F5 The PLAY function starts the Oscilloscope to measure When it starts it configures the graphs as it has been set to in the settings window When you have started the Oscilloscope you have the possibilities to change the time axis by using the SPAN buttons The Settings Menu is hidden automatically when the button is pressed To stop the oscilloscope press the STOP button Stop F4 The STOP function stops the Oscilloscope to measure After the measure has stopped it is possible to go to the beginning back forward or to the end of the graph It is also possible to increase or decrease the span of the x axis The SPAN buttons or the NAVIGATION buttons does this Span buttons With this set of buttons the user can zoom in and out in the graph either when the measuring is in progress or when it is stopped Zoom When this button is pressed the SPAN buttons is being activated Span 10 F6 One press on this button increase the span of the x axis with 10 ms Span 100 F7 One press on this button increase the span of the x axis with 100 ms
3. User Manual Oscilloscope version 1 4 3200 3250 3300 3350 3400 3450 3500 3550 Time Window 500 ms ims 3600 3650 Time Div 25 ms Table of Contents WAY OSCIIOS COD G alin hasta o E Sid 3 Oscilloscope measure specification eee rrenan Sid 4 DS SEH DUOM DUO S EE ie Aer D ain tenues Sid 5 6 Getting to Know your Oscilloscope LR Sid 7 Measure tenaient Dan Sid 8 Rio UNCU mn ee Sid 9 Eta ii estica cilada a ai aa A Sa er Sid 10 Why Oscilloscope Digital multimeter is fully enough for control of circuits in static condition and for cases where the value changes gradually But for dynamic control the engine is running and fault tracing of intermittent faults the oscilloscope is a very powerful aid In contrast to older analogue oscilloscopes for testing of high tension circuit in spark system has a modern digital oscilloscope a variable high tension scale that can show low and high tension typically 0 5 V or 0 12 V even a adjustable time scale so every type of curves can be shown on an idealist way The most oscilloscopes that has been designed for the car industry is light to carry and idealistic for use in the workshop They can also be used inside the car while it is running for collecting dynamic data Oscilloscopes screen can show shape amplitude frequency and pulse width as received signal Through an effective d
4. e button and move the mouse to the left to scroll the graph backwards and move it to the right to scroll forward If the mouse pointer is on a y axis hold down the left mouse button and move the mouse ahead to scroll up and in the opposite direction to scroll down To set the settings back to the default settings press the default button Times In the graph the oscilloscope shows two time stamps this to simplify the analysing of the Graph 0 50 100 150 200 250 300 350 400 450 500 Time Window 500 ms ms Time Div 25 ms 10
5. e is a combo box where the user can select which channel to trig on When a channel is selected a red line is showing in the graph This line is representing the trig value When the value is changed in the value settings the line is also moving There is also a setting for which edge to trig at Up edge or Down edge To start a measure with the trig function press down the PLAY button If the function doesn t find a trig the trig line is red but if the function finds a trig the trig line becomes green The trig value and the edge setting can be changed during a measure Up Edge Down Edge A i Time Window 500 ms Time Window 500 ms Extra funktions Zoom If the zoom button is pressed and the mouse pointer is moved over the x axis or any y axis the mouse pointer is changing shape When this happens and it s on the x axis hold down the left mouse button and move the mouse left to zoom in and move it to the right to zoom out If the mouse pointer it s on a y axis hold down the left mouse button and move the mouse ahead to zoom out and in the opposite direction to zoom in To set the settings back to the default settings press the default button Scroll If the scroll button is pressed and the mouse pointer is moved over the x axis or any y axis the mouse pointer is changing shape When this is happening and it s on the x axis hold down the left mous
6. lt Settings The default settings button is setting the default values both on the x axis and the y axis This is set out of the configuration in the settings window Print The print function prints out the span that is visible in the graph To make it more readable the print is printed in black and white Save The save function saves the visible span of the graph into a bmp file This file can be opened standard picture editing program wT Menu Up Down With this function you can show or hide the settings menu When you press PLAY button the settings menu hides automatically to show as much of the graph as possible When you press the STOP button the settings menu shows automatically to make it easier to change the settings Exit This function terminates the application Getting to Know your Oscilloscope Measure channels There are two different types of measure channels Probe channels Probe channels Parallel channels t 1 186 Measure Settings 1 2 2 4 Measure Cable Range 2 Pi 1 186 volvo ar 16 16 4 CH Source Cable Pin Range 5 1 6 6V MCH3 1 186 No 508 6 64 The first selection the user has to dois the type of measure 1 There are eleven different types of measure options which are P2 1 probe channel P2 P1 2 probe channels P2 P1 1 186 2 probe and 1 parallel channels P2 1 1 186 2 2 probe and 2 pa
7. rallel channels P2 1 186 1 probe and 1 parallel channels P2 1 186 2 1probe and 2 parallel channels P2 1 186 3 1 probe and 3 parallel channels 1 186 1 parallel channel 1 186 2 2 parallel channels 1 186 3 3 parallel channels 1 186 4 4 parallel channels Note that P2 is the default probe channel and has to be used when measuring on a single probe channel When one measure type is selected the Settings window 5 is filled with the number of channels in the selected measure type lf a measure with a parallel channel is selected the next selection is the adapter cable 2 When this is selected the parallel channels is filled with the cable No in the settings window 5 To be able to select a pin to the parallel channels the user has to select the specific channel in the settings window 5 and then make the selection in the Pin box 3 There is also an option to choose different ranges which are 0 6V 6 6 e 0 16 V Default 16 16V e 0 27V e 27 97 e 0 200 V Only P2 This selection is done in the Range box 4 Note that P1 and all of the parallel channels always get the same range setting When all of the necessary settings is done the PLAY button is enabled and the user can start to measure Trig function Trig Edge T a Value 16 4 With the Trig function the user have the possibility to see periodic signals in only one window In the Trigger menu ther
8. raw voltage curve vertically in ratio to time horizontal easy to connect normally only two cables and the speed of testing can wide overstep time compared to a digital multimeter This fast reaction render possible fault tracing of intermittent problems even to observe the effect of parts in the system for example when a multiplug loosen Reaction time can at necessity be sufficient long for certain signals as throttle potentiometer Later when the cause of an error has been diagnosed and taken cared of the mechanic can verify it with a new oscilloscope test The Oscilloscope can also be used to control the total condition of an engine system with catalytic converter by supervising the activity of the lambda sensor The complicated electronic engine system that has been put together in catalytic converter cars is designed to keep the blend condition in tight tolerance so that the lambdas can react on small changes in exhaust oxygen content and send back the information to the ECU in shape of a voltage signal Through watching the lambda signal with the oscilloscope can uneven in the system performance discover If the showed curve is satisfactory this is a reliable indication that the whole system is working correctly The oscilloscope for the time being can receive information and is easy to connect and use It renders possible display of a curve at the picture without special knowledge or experience Interpretation of