Home

Telescoop User Manual

image

Contents

1. 55 000 032 Ed E TeleScoop 2 User Manual 11 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hess AETA AUDIO SYSTEMS Details on the fields included in this area Codec name the dropdown list shows all the codec files available in the TeleScoop installation directory When a file is selected its data are extracted and the software immediately tries to get control over the corresponding codec Serial port only those COM ports actually existing in the PC and available i e not currently used by another application are shown in the dropdown list Select nothing if the codec is linked via a TCP IP connection IP address enter an address either in numerical format i j k 1 or in symbolic format if a name server can resolve the symbol entered in this field Select nothing if the codec is linked via a direct serial link TCP port enter the TCP port number for access to the codec Not relevant and don t care if accessing the codec via a direct serial link Codec type select the type of codec Details on the buttons included in this area e Save triggers the saving of possible changes in the selected codec file e Save as proposes to save the parameters in a file whose name can be defined e New clears all the fields preparing for the creation of a new codec file e Delete allows to delete t
2. 4 Detailed operating instructions 4 1 Basic principles and definitions The TeleScoop application controls configuration and supervision one codec at a time but several copies of the programme may run in parallel which allows to control several codecs simultaneously This is similar to e g simultaneously opening several documents on a text editor To take control over a codec the software needs some installation parameters that define the codec type and addressing e Type of the codec e COM port number or IP address TCP port number These parameters can be saved in a codec description file or simply codec file whose name can be selected Afterwards it is only needed to open this file for the software to get linked with the codec without having to enter again the installation parameters TeleScoop also uses configuration files a configuration file includes parameters relating to e The audio coding configuration e The configuration of auxiliary functions ancillary data channel relay transmission audio coordination channel A given combination of these parameters can be directly loaded just by opening a configuration file saved previously Lastly a third type of file handled by TeleScoop is the directory This includes a number of profiles Each profile in the directory includes a name one or a few dial numbers2 and possibly reference to a linked configuration file Selecting a prof
3. User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hers AETA AUDIO SYSTEMS 4 2 6 Maintenance panel buttons e Read enables to read the current configuration of the codec and update the window Network configuration System information Tests and Status areas The F5 key has same effect e Write sends to the codec the network parameters as they were edited This button is inactive for a codec such as the Hifiscoop 3 LL The F6 key has same effect 4 3 Configuration Panel This tab is used for programming the codec operating mode e Algorithm and coding parameters e Parameters of the auxiliary functions e Configuration of the audio inputs outputs A sample screen capture is visible on page 8 above The following areas can be found 4 3 1 Mode Codec 1 Codec 2 These areas enable the basic coding configuration The choice can be restricted depending on the selected coding algorithm e g e Only G711 and G722 algorithms are available in dual codec mode in addition codec 2 must be the same setting as codec 1 in some codec transmission mode combinations e g Hifiscoop 3 LL e The sampling rate is selectable only for MPEG coding For more details regarding these parameters refer to the user manual of the codec All these coding parameters can be saved in a configurat
4. 032 E TeleScoop 2 en doc hers AETA AUDIO SYSTEMS 2 2 Installation of the software The installation CD ROM is needed To install the software e Close all unused applications on the PC e Insert the CD ROM in the reader e If the installation program does not start automatically at this moment open the CD ROM in Windows Explorer then launch the SETUP MSI file in the CD ROM root e Installation starts and successive windows are shown accept the proposed choices or make possible desired changes when asked e The last Setup Complete window signals that installation is complete Click Finish The installation program has created the TeleScoop icon in the Start Menu and the Desktop An icon linking to this manual pdf format is also created in the Start Menu 2 3 Connecting the codecs to supervise As mentioned above there exist two ways of linking the PC to the codec s to supervise PC serial ports or TCP IP connections and these lead to very different hardware architectures However it should be noted that combining these two techniques is allowed as well i e a number of codecs can be controlled via direct serial links while at the same time other codecs are supervised through TCP IP connections 2 3 1 Using serial ports on the PC In such case TeleScoop directly controls each codec via a COM port on the PC COM1 to COM99 The PC can control as many codecs as COM ports are available for this purpose Each
5. present document This document is an Acrobat pdf file in the same language as the one selected for the user interface of TeleScoop 5 7 Shortcuts The menu items can be accessed by using the keyboard Alt key then hit the letter underlined in the menu or sub menu item Example Alt F O open codec file 24 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc Chess AETA AUDIO SYSTEMS Besides four function keys can be used e F3 Activate deactivate cyclic check e F5 Read the configuration and status of the codec and update the window e F6 Write send to the codec the parameters on screen and write them into the codec memory e F8 Toggle the display mode normal or compact To manage the communication links the following key combinations are also available when the Communication panel is active e Alt 1 Unhook hang up codec 1 e Alt 2 Unhook hang up codec 2 e Alt 3 Unhook hang up both codecs Note that no confirmation is asked by the software when using a shortcut to hang up The software can be launched by double clicking a codec file aet extension This loads the software and directly opens the codec file then the control link with the codec is opened 1 Warning if only one codec is on line this will systematically hang it up 55 000
6. the screen Key F5 has same effect e Write sends to the codec all the configuration parameters coding auxiliary functions audio inputs outputs as they were edited Key F6 produces the same result The Save as and Open buttons have no influence on the audio inputs outputs settings as these settings are not saved in the coding configuration files 16 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hess AETA AUDIO SYSTEMS 4 4 Communication panel This tab allows to manage communication links set by means of the codec It is not available for a Hifiscoop 3 LL codec or a multiple network codec e g Hifiscoop 3 ISDN Scoop 4 when the active interface is the X21 V35 interface The panel is divided into two areas The left part CODEC 1 is always active and only this one is active in normal single codec mode The right part CODEC 2 is operative only when the codec is configured in dual codec mode available for ISDN transmission mode In dual codec mode communication can be managed independently on the two codecs Each codec only transmits on one B channel and only one dial number per codec is needed for this reason the CODEC 2 area only includes one Dial number field In the following only the operation for managing CODEC 1 in si
7. 032 Ed E TeleScoop 2 User Manual 25 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc Chess AETA AUDIO SYSTEMS 6 Miscellaneous applications 6 1 Simultaneous supervision of several codecs It is possible to manage several codecs simultaneously from the same computer The supervision is especially eased by the compact display mode First of course the necessary physical links between the PC and the codecs have to be set One approach consists in fitting the PC with extension boards to provide it with asynchronous serial ports one COM port for each codec In another approach the PC is connected to an IP network for example an Ethernet IP local area network and each codec is connected to a serial port server connected to the same network in addition Scoop 4 codecs can be directly connected to an Ethernet LAN As an advantage of this second technique the codecs need not be close to the PC they may even be located at a long distance if the link goes via Internet as an example The next step is to install in the TeleScoop application the various codecs i e create definition files corresponding to the codecs From this point TeleScoop can take control over any codec by merely opening the corresponding codec file Beyond quickly accessing any codec in the pool it is also possible to open several codec files at the s
8. Chess AETA AUDIO SYSTEMS TeleScoop 2 Codec configuration and supervision software User Manual File Panel Tools Display Link Help 2 Maintenance dy Configuration Communication m Installation a Codec name Studio 55 fe Save Gg Save as O New J Delete Serial port T IP address 63 1 20 146 31 TCP port e001 HIFISCOOP 3 ISDN HIFISCOOP 3 ISDN HIFISCOOP 3 LL m usem infrrmatinn gt _ Seen Codec type AETA AUDIO SYSTEMS 18 22 avenue Edouard Herriot Kepler 4 92350 Le Plessis Robinson FRANCE T l 33 1 41 36 12 00 Fax 33 1 41 36 12 69 Web hittp www aeta audio com 55 000 032 Ed E TeleScoop 2 User Manual This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hers AETA AUDIO SYSTEMS Table of contents 1 Introduction Functions of TeleScoop cccssccssssecssseee L De Vista ation ccceccsscccsteccsicees usetetetssacesccssecsbetssoteccsesscstesvacesscssevstes 2 2 1 Required system Configuration cece seeesecseeseceeeeecseceeeeeaeeeesaeeaeeaes 2 2 2 Installation of the software cc eeeeeeeeceeeeeesecseeseceeesecsaeeeeaeceetseeneeaeenee 3 2 3 Connecting the codecs tO SUPELVISC eeeeeeceseeeeesetseeeceeereneeeeeaeeeteees 3 3 Quick SUA siccicicesccacsnad teentaasesaatesnccanadeincasneenceec
9. Configuration r Installation p Network configuration Codec name ISDN protocol Prefix E Save led Save as n Transmission interface Di New Delete Local numbers Normal codec mode SA Serial port z mj A mj IP address mj TCP port 6000 eoe E Codec type HIFISCOOP 3 LL x ens System information Seky Local numbers Double codec mode UN board Current password uc aj Ha Change password Miscellaneous Incoming calls accepted F Hi Csi Date Tests Telephone p Test Loop None gt P me id wi Status gt Status PC Codec link Power supply Cock1 Clock 2 Codec 1 Er AETA AUDIO SYSTEME The Maintenance panel is proposed The next step is to install a codec i e supply the TeleScoop software the parameters for setting a control link with this codec 55 000 032 Ed E TeleScoop 2 User Manual 5 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc Chess AETA AUDIO SYSTEMS 3 2 Installation of a codec In the Installation area select or enter the parameters corresponding to the codec e Serial port the ports available on the PC appear in the dropdown list select the COM port the codec is connected to For a TCP IP connection select nothing there e IP address enter here t
10. a TCP IP connections This latter method is interesting for controlling a number of codecs grouped in the same place The compatibility of the multiport server with TeleScoop should be checked Each codec must be connected to the multiport server using a serial cable connected on the Remote port of the codec The wiring of the cable on the server side depends of its type and configuration refer to the installation and configuration instructions provided by the server manufacturer The serial port linked to a codec must be configured 4800 bauds 8 bits 1 stop bit no parity no flow control 4 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc he s AETA AUDIO SYSTEMS 3 Quick start 3 1 Launching the software Check first see above Connecting the codecs to supervise that at least one codec can be accessed either via a serial link between the PC and the codec or via a TCP IP connection in which case the IP address and TCP IP allocated to the codec are known Launch the software by selecting it in the Start menu or double clicking the TeleScoop icon On the first use if necessary switch the language to English menu Outils then English the control panel appears as follows lt LL TeleScoop 2 2 0 File Panel Tools Display Link Help Maintenance f
11. ame time or even all the codec files One copy of TeleScoop is active for every open file One can instantly access every codec by just switching the computer to the task supervising this codec Using the compact display mode and adequately setting the windows on the screen one can get an overview of all the supervised codecs and get a visual warning in case of a fault on a codec At this time just clicking on the window signalling an error will switch the window to normal display mode thus providing detailed monitoring on this codec Once the intervention is finished hitting F8 key brings back to compact display and the overall view 26 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hers AETA AUDIO SYSTEMS 6 2 Directory Import Export It is possible in some cases to import or export the data of the TeleScoop directory file from or to another application The process consists in importing or exporting the data to from the directory file Numbers ann this file resides in the TeleScoop installation file One simple way to do so is to use a spreadsheet editor capable to import data in text format As a guide for such purpose the following sample files can be found in the TeleScoop installation directory e example ann file sample directory file with same format as t
12. amp es Status p CODEC1 ir laces 3 r Status Call progress PC Codee link MPEG LAYER Il Power supply E ABkHz Stereo Di Cock Cook 2 Codec Er I Auto answer EA i Save as isl Clipping Dial number Ole pumber me S ni _ La 4 Test loop T I Cycle ro iia C Wa J a IE Linked coding configuration X f amp Read ETA AUDIO SYSTEME Request Read general parameters OK The most straightforward way of setting a call is to enter the necessary dial number s Dial number fields on a white background then to click on the Call button It is recommended to check the Cycle checkbox in the Status area so as to permanently monitor the codec operation and especially for monitoring call progress and to be warned of incoming calls In daily operation using the directory functions of TeleScoop should be preferred To prepare a call one just has to pick up a name in the Profile dropdown list to get directly all the numbers for a remote device that was already registered in the directory To go beyond this quick start the following chapters include further details about all the capabilities and behaviour of TeleScoop 55 000 032 Ed E TeleScoop 2 User Manual 9 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc Che s AETA AUDIO SYSTEMS
13. an ISDN or IP link is running This variable icon is also visible in the task bar so the information is available even when the application is running in the background without the need to restore the TeleScoop window Please note that some display parameters are saved into the codec files so they are restored automatically each time a codec file is opened e Current display mode normal or compact e Window position on the screen 22 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hers AETA AUDIO SYSTEMS 5 Menus Shortcut keys 5 1 File Menu e New codec file is equivalent to clicking on the New button in the Installation area Maintenance panel and it allows to clear all installation parameters in order to prepare the definition of a new codec e New profile for codec 1 is equivalent to clicking on the New button in the CODEC I area Communication panel and it allows to clear all the profile fields ready to create a new one e New profile for codec 2 is equivalent to clicking on the New button in the CODEC 2 area Communication panel e Open coding configuration file is equivalent to the Open button in the Configuration panel e Open codec file has the same function as the dropdown list of the Installation area Maintenance panel e Recent gives a quic
14. call the codec first loads the linked coding configuration then calls the remote device as required Using this feature the profile of a remote device describes both its addressing and the coding configuration needed for a link This function is not available in double codec mode Selection of linked configuration this dropdown list enables to select among the configuration files saved on disk the one to be linked to the profile Several buttons are available for the following functions Foldback this button appears when an MPEG link ends up with a configuration different from the initial one If clicking on the button a message window describes the current configuration of both the encoder and the decoder they can happen to be different Note although a foldback is an alarm condition the link does not necessarily fail Foldback may have little consequence in some cases example foldback to mono in one direction of the link Call button this button has two functions it is used for setting a call or hanging up when a link is active and it also displays the link status In manual answering mode the button is also used for accepting an incoming call New button click on this button to clear the profile selection as well as all the dial numbers Save button click on this button to save in the selected profile all the dial numbers and sub addresses as they are displayed and the linked configuration if there is one select
15. codec to supervise must be linked to the PC via a serial link cord The cable must include a 9 pin female sub D plug to be connected on the serial port of the PC and a 9 pin male sub D plug to be connected on the Remote port of the codec The cable is straight pin to pin a PC to modem cable is adequate a null modem cable is not lor possibly other installation media 55 000 032 Ed E TeleScoop 2 User Manual 3 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc Che s AETA AUDIO SYSTEMS 2 3 2 Using TCP IP connections In this case TeleScoop controls each codec via a TCP IP connection The PC must be connected to an IP network the codec is also connected to There is almost no limit to the number of codecs that can be reached from the PC in this way There is a large variety of network access configurations and setting up such system is beyond the scope of this manual we can just mention two typical cases e Access to an Ethernet local area network under IP e Remote access to Internet via a telephone or ISDN connection The codec can access the network in two ways e Either the codec includes an Ethernet interface as is the case for a Scoop 4 codec and it can be connected directly to an Ethernet LAN e Fither a serial terminal server is used that can provide access to a number of serial ports vi
16. d Power supply red indicator in case of a power supply alarm in the codec Clock 1 red indicator in case of a clock fault on X24 X21 V35 transmission interface n 1 This indicator is relevant only for a leased line interface Clock 2 red indicator in case of a clock fault on X24 X21 V35 transmission interface n 2 This indicator is relevant only for a leased line interface and only in dual codec mode 20 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hers AETA AUDIO SYSTEMS Codec I this indicator is off when the codec is idle green when it is on line with no error red when it is on line but with errors decoder fault An encoder or decoder foldback alarm may also switch this indicator to red in which case the foldback condition is specified Codec 2 this indicator is off when the codec is idle or does not exist single codec mode green when it is on line with no error red when it is on line but with errors decoder fault An encoder or decoder foldback alarm may also switch this indicator to red in which case the foldback condition is specified Clipping yellow indicator on in case of clipping at the encoder input whatever the A or B audio input of the codec AES red indicator on in case of a fault on the AES input except if not relevant e g i
17. der faldb e Decoder foldback Codec 2 Encodentaldbank Qessdes foldback Cipping aes Test loop T Cycle E Read AETA AUDIO SYSTEME Request Read status OK 2 Scoop 4 codec connected via a TCP IP connection MyScoop4 via TCP Sc4 IP TeleScoop V2 4 2 Eile panel Tools Display Link Help Z Maintenance A Configuration amp Communication Installation Codec name Network configuration ISDN protocol Prefix MyScoop viace a VN rence z H Save 74 Savoa Transmission interface IP Ethernet X C New fl Delete Local numbers Normal codec mode SA Serial port X IP address 10 0 20 16 TCP port 6000 I Codec type SCOOP 4 x ISDN board pC 114 DSP j System information p Security Local numbers Double codec mode Current password aj Change password Miscellaneous Incoming calls accepted Al Data __ Telephone Status Status PC Codee link Power supply Q Bibat Codec Eneader tal pues Codec 2 E te Cipping s Test loop T Cycle AETA AUDIO SYSTEMS Request Read general parameters OK Now the codec can be totally controlled 55 000 032 Ed E TeleScoop 2 User Manual 7 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleSco
18. e screen then click on the Write button in order to send to the codec all the parameters after all these changes The actual resulting status of the codec is read back after this write process When the codec is connected to a permanent transmission link normal situation e g for a codec like the Hifiscoop 3 LL the setting up of the codec is now completed provided the codec was adequately installed and configured The Status area on the right of the screen informs on the operation status of the codec 1 Note that the Read button changes colour to warn that the displayed data may then differ from the actual configuration of the device 8 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hess AETA AUDIO SYSTEMS 3 4 Setting up an ISDN or IP link In case the codec under control is used for transmission via a switched network or IP network TeleScoop will now enable the management of links established thanks to the codec and especially allow to send calls to remote equipment Click on the Communication tab or using the menu select Panel Communication The proposed window has following layout 2 Codec 55 HiSc3 ISDN TeleScoop 2 2 0 2 5 x File Panel Tools Display Link Help amp Maintenance 3 Configuration
19. ed Save as button click on this button to save all the dial numbers and sub addresses and the possible linked configuration into a new profile whose name can be defined at will ti button click on this button to delete the selected profile from the directory A confirmation is required The icon on each line dial number SA allows copying the dial number and sub address from the line just above 55 000 032 Ed E TeleScoop 2 User Manual 19 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hess AETA AUDIO SYSTEMS 4 5 Status area This area is always visible on the right end of the window It includes a number of indicators that display the codec status possible alarm conditions and the status of the links for a codec on a switched network After having read the codec status the area generally appears as follows R Status r Status PC Codec link Power supply Clock 1 Clock 2 Clipping AES Test loop V Cycle A Read Function and meaning of the items in this area PC Codec link this indicator is green when the link between the PC and the codec is operating correctly and red when it fails The indicator lights off when closing the link or if the data displayed in the area have low reliability e g if this information was not recently update
20. eous applications sesessccossssscossssooesesooeessosesesse 20 6 1 Simultaneous supervision of several codecs ssseseseeeereeeerereerersrrreereee 26 6 2 Directory Import Export esner aris aN Eaire 27 55 000 032 Ed E TeleScoop 2 User Manual This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc he s AETA AUDIO SYSTEMS 1 Introduction Functions of TeleScoop The TeleScoop software is used for configuring and supervising AETA AUDIO SYSTEMS codecs thanks to a PC With a leased line transmission codec like Hifiscoop 3 LL it is used especially when setting up the codec for programming the operation parameters of the codec Used with a codec for ISDN or IP transmission like the Scoop 4 one can also manage the setting up of communication links with the codec TeleScoop proposes the following functions e Reading the current configuration and status of the equipment e Changing the coding configuration parameters of the equipment e Loading predefined configurations which are described in configuration files that can be edited and recorded thanks to TeleScoop e Changing installation parameters of the codec especially network access parameters e Managing the communication links call set up from the codec incoming call monitoring a directory eases the handling of dial numbers and the identification of incoming ca
21. er when this box is checked the codec automatically answers an incoming call It is recommended to select Cycle codec status read in the Status area in order to monitor possible incoming calls Profile this dropdown list enables the selection of a profile from the directory On selecting a profile in the list the dial numbers of this profile are loaded as well as a possible linked coding configuration see further Dial number here the dial numbers for calling a remote device can be entered directly or a profile can be selected to load all the numbers The numbers actually needed for the current coding configuration have a white background while the others have a yellow background In the example shown above the codec is configured for MPEG at 192 kbit s so three numbers are needed for calling another codec The icon makes it easy to copy a number from one line onto the following one S A these are the sub addresses possibly allocated to the dial numbers Note not relevant for IP transmission mode 1 A dial number is an ISDN number or for audio over IP mode an IP address or a SIP URI 18 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hers AETA AUDIO SYSTEMS Linked coding configuration if this box is checked when the user asks for a
22. f the digital audio interfaces are not used Test loop this yellow indicator reminds of the possible activation of a test loop Cycle when this box is checked TeleScoop periodically reads the codec status and updates the Status area Note that the rest of the window is not updated Read button click on this button to read and update the codec status Status area the rest of the window is not updated The software queries the codec only once except if cycle read is activated 55 000 032 Ed E TeleScoop 2 User Manual 21 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc Che s AETA AUDIO SYSTEMS 4 6 Display modes The display described up to now is the normal display mode of the application TeleScoop can also display the codec status in a smaller window in order to ease the simultaneous supervision of several units from the same computer One can switch to a compact display mode using either the menu or the F8 key In the compact mode the very small sized window only shows the codec OK status as can be shown in the example below Z LL via COMI esl es Codec 1 Codec 2 In both display modes the title bar of the TeleScoop window includes an icon which changes depending on the global status of the codec al ene ae when operation is OK e in case of a fault oR when
23. he TeleScoop directory file e example xls file resulting file after importing example ann to Excel format a title row was added to help understand the format These sample files can be edited with no consequence on the operation of TeleScoop 1 Important notice this file must be saved prior to importing exporting data to from the TeleScoop directory Doing so in case of a problem it is still possible to restore the original data by restoring the file in its original location Unless taking such precaution part or all of the information initially included in the directory might be lost because of incorrect or erroneous handling AETA AUDIO SYSTEMS cannot be held responsible for the loss of data caused by failing to import export data to from TeleScoop 55 000 032 Ed E TeleScoop 2 User Manual 27 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc
24. he IP address allocated to the codec or the terminal server the codec is linked to For a direct link via a COM port do not enter anything in this field e TCP port enter the TCP port number allocated to the codec For a direct link via a COM port do not enter anything in this field e Codec type select the type of codec in the dropdown list Whenever needed enter the password protecting access to the device in the Current password field Then click the Save as button and enter a name for the codec that was just created TeleScoop then creates a file with this name From this moment all the above parameters can be instantly recalled by loading this codec description file into TeleScoop and there is no need to enter these parameters again Important notice as the codec description files are stored in the program installation directory by default depending on your system configuration you may be refused the right to save such files If this happens then save the file in another directory where you have full access rights As soon as the file is saved TeleScoop sets up a control link with the codec and updates the display to reflect the codec status especially in the Status area A message is displayed if TeleScoop fails to establish this control link Depending on the message especially check whether the selected serial port is the right one or if the TCP IP addressing is correct or simpl
25. he selected codec file A confirmation is asked for cancels all new inputs or changes and comes back to the original parameters of the last selected codec file 12 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hers AETA AUDIO SYSTEMS 4 2 2 System information After reading the codec this area shows the version numbers of the codec software e ISDN board version of the ISDN interface board software not relevant for all models e uC version of the micro controller software e DSP version of the signal processing software not relevant for all models The version number is different for each coding algorithm 4 2 3 Security The current password of the codec is displayed in this area It is saved in the codec file The Change password button can be used for changing the password in the device as well It is obviously recommended to handle this parameter with utmost care 4 2 4 Tests Depending on the codec type a test loop can be activated by selecting it in the list The loop is immediately activated and a yellow indicator in the Status area recalls the activation of the test loop 55 000 032 Ed E TeleScoop 2 User Manual 13 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleSco
26. ile directly recalls all the parameters useful for setting a link with a remote device 1 This function is an option available on AETA AUDIO SYSTEMS codecs 2 A dial number is an ISDN number which may itself include a sub address or for audio over IP mode an IP address or a SIP URI 10 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc hers AETA AUDIO SYSTEMS 4 2 Maintenance panel This tab is used for the following needs e Installation of a codec and creation of its codec file e Selection of the active network for units which have more than one transmission interface e Configuration of the ISDN interface ISDN codecs only e Maintenance and supervision checking version numbers activating test loops password programming Two screen capture samples are shown on page 7 above The following areas can be found on the panel 4 2 1 Installation This area groups the installation parameters those needed to access a codec and take control over it These parameters are saved in a codec file with aet extension It is mandatory to save such a file or have it available already in order to control a codec please read the important notice in chapter 3 2 above 1 Note that the password and the dial prefix are also stored in the codec file
27. ion file or loaded from such a file see the function of the buttons on this panel 55 000 032 Ed E TeleScoop 2 User Manual 15 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc Che s AETA AUDIO SYSTEMS 4 3 2 Auxiliary functions This area allows to activate when needed the auxiliary functions and to select the baud rate of the data channel Here again the valid choices depend on the type of the codec and the coding algorithm a message warns about a possible invalid combination These parameters can be saved in a configuration file or loaded from such a file see below the function of the buttons 4 3 3 Audio I O The format and setting of the audio inputs outputs can be selected in this area For details on these settings please refer to the user manual of the codec Important notice Saving or opening configuration files has no influence on these parameters 4 3 4 Configuration panel buttons e Save as proposes to save the coding and auxiliary functions settings Mode Codec 1 Codec 2 and auxiliary functions areas into a coding configuration file whose name can be selected e Open conversely allows to load such parameters from a configuration file previously saved e Read allows to read the current configuration of the codec and update the whole window including the Status area on the right of
28. k access to the most recently used codec files e Quit closes the application This has no effect on the codec operation as its operation parameters are all saved in the codec memory 5 2 Panel Menu This menu is one way of selecting the desired active panel Maintenance Configuration or Communication The Communication panel is not available for a Hifiscoop 3 LL codec 55 000 032 Ed E TeleScoop 2 User Manual 23 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc Chess 5 3 Tools Menu e Cyclic check allows to activate or deactivate the periodic monitoring of the codec status e English allows to select the English language for all the texts displayed by the software e Francais allows to select the French language for all the texts displayed by the software e Reset enables to reset the codec this control may be inoperative on older versions of the Hifiscoop 3 LL 5 4 Display Menu This menu allows to switch the display mode to compact and vice versa 5 5 Link Menu With this menu it is possible to close the communication channel i e either close and release the COM port when a serial port is used or close the TCP IP connection Conversely it is possible to restore the channel 5 6 Help Menu e About shows the version number of the TeleScoop software e Help allows to open the user manual
29. lls e Supervision of several units from the same computer via serial links and or TCP IP connections In this manual the reader is expected to be aware of the functions capabilities and limits of the codecs that TeleScoop controls Whenever needed please refer to the user manuals dedicated to these codecs 55 000 032 Ed E TeleScoop 2 User Manual 1 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc Che s AETA AUDIO SYSTEMS 2 Installation 2 1 Required system configuration The system minimal requirements for proper operation of the software are as follow e e Pentium PC computer Windows operating system all versions including Windows Vista 10 Mb available on hard disk Display 1024x768 256 colours CD ROM reader At least one serial port must be available for linking the PC with a codec except if controlling the codec s through TCP IP connection s In such case the PC must be granted access to a network enabling such link s Winsock must be installed on the PC to allow this link mode You must have administration rights on the computer to be allowed to install this software otherwise the installation will be aborted 2 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000
30. ncaseacndverencianversaded 3 1 Launching the software is scnideiiasediediilitisiiaeoniiieens 5 3 2 Installation Of a CO C ec eeeeesecseeeeceseeeeeseeeeesecaeeseeseeeecsaeseeeeesaeeneaeeaees 6 3 3 Coding Configuration cceseseseeseeeeceseeeeeseeseesecseeseesaeeecaeeeeeecsaeeeseaeeaee 8 3 4 Setting up an ISDN Dink 0 ee essescesseeseescsessesseesonescercesesesssesessesresssees 9 4 Detailed operating instructions ccscccsessesssrcesssreeee 10 4 1 Basic principles and definitions cc ceeeeeeseceeeeceeeeeeeeeaeeseceeeeenaeeees 10 4 2 Maintenance panel ccsceesecscecsceeseeeseeeseeeceeeeceeeeseeeseceeeeeaeenaeeaeeaes 11 4 3 Configuration Panel i 0 occistsensseteneeetes onanidvsussancesehsqacvegesebenesserspeaseias 15 4 4 Communication panel ceeesceceseceesceceseceeseeceneeeeneeceeeeeeaeceeeeeenaeeeeee 17 Aids DAUS ARCA eeaeee enei teed seqsugesadveces E A E EES 20 4 6 Display MOdeS esesten seneesa oa sE aonn EEOSE ANENE AASS ENK 22 5 Menus Shortcut keys ccscccssssssssssssssscssssssssssscsssccssssssses 29 SA Fle Meni sirien 23 D2 Panel MOM ocon ee N EA E EE RE E 23 5 3 LOOMS MeNi cmicnoninni vayieussescyensssocasureeeneigecsess 24 5 4 Display Ment scicciccidsiaiash tivities dante ainas 24 925 Link Men soiin ei eeno K NE EEE N alias 24 5 6 Help Men sinna nenea E E E A E EIR 24 Dials SDOTCU Sunpet ET RE A A 24 6 Miscellan
31. ngle codec mode is described The operation in dual codec mode is easily derived from this A sample screen capture can be found below detail of CODEC 1 area pA Maintenance A Configuration Communication CODEC 1 Summary Call progress E LAYER II _ of initial READY 192k 48kHz Stereo configuration 0123456780 IV Auto answer i Profile Studio 55 7 O New E Save i Save as i Dial number S A arzaascre0 SO Selection J Linked coding configuration of linked configuration zi 55 000 032 Ed E TeleScoop 2 User Manual 17 This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc Che s AETA AUDIO SYSTEMS The window includes the following fields and selections Call progress this area informs about the progress of outgoing or incoming calls by showing current status or step dial number of remote device called or calling party depending on the situation name of corresponding profile Either the profile has been selected for setting the outgoing call or it was recognised on receiving the incoming call thanks to the caller identification Summary of initial configuration this describes the coding configuration prior to establishing a link After establishing a J52 link the actual configuration may eventually differ from this so called initial configuration Auto answ
32. op 2 en doc Che s AETA AUDIO SYSTEMS 3 3 Coding configuration First in order to check the coding configuration click on the Configuration tab or using the menu select Panel Configuration The software presents a layout similar to the following A 5AS HiSc3 SAS ISDN TeleScoop V2 4 2 File Panel Tools Display Link Help J Maintenance A Configuration le Communication Status Mode Auxiliary functions Audio 1 0 Normal Data channel 1 0 format Double Codec audrai Analog F AES Status PCCodec tink Power supply Coding 1 MPEG Layer Il J52 v AES samplin ayerll J52 x aS iaa E Codec 1 Sampling rate Codec 1 9600 Ba AES clock i 48 kHz Audio mode Stereo Codec2 c c Max Input level d I Relays wain Clipping Bit rate 16 dBu 192 kbit s I Audio Coordination es Error correction Output level Test loop Mode O None 16 dBu I Cycle i Save as ir Read Codec 2 Load impedance Ge Coding Open High 600 0hm oa lt 3 BR P Read Cig a Wite Cig F5 F6 Fy oy Request Read coding parameters OK In the previous step the software normally has read from the codec its current configuration Anyway the configuration can be read again at any time by clicking the Read button or pressing the F5 key It is possible to change the codec configuration if needed first change the configuration on th
33. op 2 en doc Chess AETA AUDIO SYSTEMS 4 2 5 Network configuration This area enables to select the active transmission network and configure the ISDN interface It is inactive for a codec such as the Hifiscoop 3 LL which only has a leased line interface ISDN numbers line 1 ISDN numbers line 2 ISDN numbers line 3 m Network configuration ISDN protocol Pretix JetsiwoisoN fo Transmission interface jsn Local numbers Normal codec mode SA a o e s E E a OoOo Local numbers Double codec mode Bo ofh Miscellaneous Incoming calls accepted M HLC all C Data Telephone The area is updated each time the codec is read and its contents is copied onto the codec whenever a write is done with the Write button The codec is read on its first installation or when the codec file is selected or when clicking the Read button e Prefix contrary to the others this parameter is stored in the codec file The prefix is systematically added before every dial number e The button allows direct copying of the number in the line above This proves useful as usually only the last digits differ even when there are several local numbers e The ISDN numbers of lines 2 and 3 must be configured only if the codec is actually equipped with these interfaces Please refer to the user manual of the codec for details regarding the network settings 14 TeleScoop 2
34. y whether the codec is properly connected The two following screen captures show examples of the result when the PC Codec link is properly set 1 The port number is 6000 for a Scoop 4 when it is controlled via its Ethernet interface 2 in the standard factory configuration this password is 1234 for a Hifiscoop 3 LL it is blank for other codec types 6 TeleScoop 2 User Manual 55 000 032 Ed E This document is the property of AAS and can not be duplicated without authorisation October 2008 55 000 032 E TeleScoop 2 en doc ANS AETA AUDIO SYSTEMS 1 Hifiscoop 3 LL codec connected via a serial port SALL via COM1 LL TeleScoop 2 2 0 File Panel Tools Display Link Help F Maintenance Jy Configuration p Installation Codec name Serial port LL via COM1 el Save Ged Save as Transmission interface CI New fl Deste Local numbers Normal codec mode S A coMt IP address TCP pott 6000 Codec type HIFISCOOP 3 LL z r Network configuration ISDN protocol p tefi l N TAM System information Sct Local numbers Double codec mode SBN board Current password ue 7 40 fi 234 mj DIR 318 Change password Miscellaneous Incoming calls accepted FP Hue C si fF Dale Tests Telephone he IP Read TPY Loop None X Te 5 iojxj P Status r Status PCCodee link Power supply Clock1 Clock 2 Codec 1 Enco