1. two permanently inflated side formers assist in lateral support for the user and carer while increasing the effectiveness of the one in three alternation cycle The hinged mattress base conforms to movements of a profiling bed Installation Unpacking amp Inspection NOTE It is recommended that all packing materials and instructions are kept in the carry bag provided in the event of the product being shipped to your local Invacare Ltd sales office SoftAIR Excellence The shipping carton contains a complete and readily assembled mattress system consisting of SoftAIR Excellence mattress system including mattress base CPR tag air hoses handle with transport cap attached and two inflatable side formers Carry Bag Digital Control Unit e Medical grade power cord Quick setup guide User manual Carefully remove the Control Unit mattress and accessories from the shipping cartons Inspect all items for any damage that may have occurred during transportation Any damaged or missing parts must be reported to your local Invacare Ltd sales office immediately Please refer to the back page for contact details Installation System Installation Control Unit Activation The following describes the procedures for initial a Position the Control Unit by placing the hooks over system set up the foot board of the bed or side rails a Remove all covers sheets and the mattress from the bed e b Conne
2. the Control Unit in any type of liquid This could result in a severe electrical hazard as this equipment has no protection against ingress of water A This equipmentis not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Wipe down Control Unit with warm water containing detergent or with a solution of Sodium Hypochlorite or similar and dry thoroughly before use Maintenance amp Cleaning Air Filter Replacement 1 Switch off the power supply to the Control Unit 2 Disconnect the power cord and air hoses 3 Place the Control Unit on a flat surface with its back panel uppermost place soft cloth under unit to prevent scratches 4 Carefully remove the air filter cover Remove and discard the filter and fit with a new filter there may be asmall locking screw use a small Phillips Head screwdriver to remove this first 5 Refit the air filter cover to the Control Unit The Control Unit is now ready for re connection A Good filter maintenance is critical to maintain your SoftAIR system to optimal operating condition Failure to keep the filters clean will result in system downtime and increase repair costs It is recommended that the air filter be replaced annually Replacement air filters are available from your local Invacare Ltd sales Office Fuse Replacement 1 Switch off the power supply to the Control Unit 2 Remove the power cord fr
3. Soft User Manual SoftAir EXCELLENCE 250mm Alternating Mattress System CH Yes you can SoftAir EXCELLENCE User Manual Important Notice Before operating this medical equipment itis important to read this manual and understand the operating instructions and safety precautions Failure to do so could result in patient injury and or damage to the product If you have any questions please contact your local Invacare sales office Please refer to the back page for contact details CE Contents SAFETY PRECAUTIONS 4 PRODUCT OVERVIEW 5 INSTALLATION 6 Unpacking amp Inspection 6 System Installation 7 Control UnitActivation 7 OPERATION icii ranan musememrane 8 Control Unit Panel 8 Mattress Function 9 Alarm Functions 10 Removal amp Transport Function 11 TROUBLESHOOTING 12 CLEANING cece hk Maka KENNY 14 MAINTENANCE 16 TECHNICAL SPECIFICATIONS 17 WARRANTY INFORMATION 18 SoftAir EXCELLENCE 250mm Alternating Mattress System Safety Precautions In General A Do not use this equipment in the presence of flammable anesthetics A Bed frames used with the systems can vary greatly depending on the specific health care setting i e hospitals nursing homes home care A
4. are Ltd its distributors officers directors employees or agents shall be liable for consequential or other damages including but no limited to personal injury loss or any other expense directly or indirectly arising from the use of its products The sole remedy for breach of the limited warranty granted herein shall be repair or replacement or the Invacare Ltd products Product life Cycle The product life cycle quoted can be exceeded if the product is maintained as per Invacare maintenance and cleaning guildlines The life cycle can also be considerably reduced if the guildlines for maintenance and cleaning are not followed or by unintended use Yes you can Invacare UK Ltd Pencoed Technology Park Pencoed Bridgend CF35 5AQ UK Tel 44 1656 776200 Fax 44 1656 776201 Technical Services Tel 44 1656 776333 Fax 44 1656 776330 Invacare Denmark Invacare EC Hong A S stergade 3 DK 4270 Hong Denmark Tel 45 58 85 27 22 Fax 45 58 85 43 86 Invacare Norway Invacare AS Grensesvingen 9 Postboks 6230 Etterstad N 0603 Oslo Norway Tel 47 22 57 95 00 Fax 47 22 57 9501 Invacare Sweden Invacare AB Fagerstagatan 9 S 163 91 Spanga Sweden Tel 46 8 761 70 90 Fax 46 8 761 8108 Invacare Ireland Ltd Unit 5 Seatown Business Campus Seatown Road SWORDS County Dublin Tel 353 1 810 7084 Fax 353 1 810 7085 CE www invacare com Part number 1550997
5. are Ltd recommends placing the cord under the bed frame and attaching it to an electrical outlet at the head of the bed SoftAIR Alternating Mattress System The SoftAIR Excellence is a alternating mattress system that provides pressure application and release to patients who are vulnerable to or suffer from pressure ulcers Itis designed to replace an existing mattress and can be used on both standard and profiling bed frames Digital Control Unit The Control Unit provides the air supply to the mattress e Itis controlled via a touch panel with integrated digital display The alarm sounds when pressure fails or power is interrupted The Alarm Mute button silences the alarm for a maximum of 20 minutes The alarm resumes if cause of failure is not resolved The alarm will sound for up to two hours following an interruption to power As soon as power is restored the battery memory back up will restore the latest pressure user settings The Control Unit is fitted with an on board battery The battery powers the alarm sounder in the event of a total power failure or power interruption The buttons on the control panel adjust the eight comfort level settings The system will automatically revert to Alternation Mode after 20 minutes in Static Mode See page 8 for further instructions TheAlarm LED indictor and Alarm Mute completes the profile The visible and audible alarm function has a number of indications depend
6. bed side rails f Once the Mattress is fully inflated the bedding can as straps will tear be placed Fit sheets loosely enough to allow for free movement of the mattress air cells Operation Control Unit Panel Power Fall A Power Button Turns system power on and off B Alarm LED The red light will flash and an audible alarm will sound to alert when the Control Unit or mattress pressure fails The alarm has five different signals to indicate the cause of the failure The audible alarm also sounds when power is switched off Press the Alarm Mute to silence C Alarm Mute Button This button silences the audible alarm on off Audible alarm will resume after 20 minutes if cause of failure is not resolved D Mode Button Press to select either Alternation Mode alternative cells cyclically inflating and deflating or Static Mode all cells fully inflated with no dynamic alternation Static Mode will automatically revert back to Alternation Mode after 20 minutes 80 95 110 125 kgs gt so 140 155 E Pressure Arrow Buttons Press the arrows to increase or decrease the pressure setting Eight pressure settings are available from soft to hard 18mmHg to 60mmHg 6mm g per step The green LEDs illuminate to indicate which of the eight settings is operational F Max Firm Button Press to facilitate rapid inflation to maximum pressure setting 60mmHg After 30 minutes the system automatically re
7. ctthe handle to the Control Unit Ensure the air hose does not kink between the bed frame and H H Control Unit b Ona standard bed position the mattress on top of the bed frame with the top cover facing upwards The air hoses should be at the foot end of the bed for positioning of the Control Unit c Attach the mattress to the bed by securing the two adjustable straps under each end ofthe bed c Insertthe power cord into the Control Unit then plug into a grounded 220V 50Hz electrical outlet H v x H d Press the power button for at least two seconds to activate the Control Unit Ensure buckles are securely fastened and straps The pressure LEDs will flash indicating the system are pulled tight has activated For detailed operation instructions On a profiling bed secure the adjustable straps see Page 8 Control Unit Panel around the profiling sections ofthe mattress platform e e e Please allow up to a maximum of 50 minutes for d To avoid any risk of damage to the mattress ensure the mattress to fully inflate Once ready the first there are no sharp objects which may come into four pressure LED s plus Alternating Mode LED will contact with it illuminate to indicate that the system is ready for use A Check that the attachment of the Mattress does system automatically defaults to Alternating Mode after not interfere with the movement or operation of start up the bed Do not secure straps to
8. evel based on current pressure and adjust accordingly Invacare recommend that the alternating mode is resumed once transportation is complete A Regularly perform a Bottoming Out test to ensure the patient is appropriately supported as air pressure is released from all internal static cells as well as alternating sections Operation System Removal 1 Switch off the Control Unit and disconnect from mains supply Remove the rapid release handle from the Control Unit and disconnect the CPR tag Place the Control Unit and power cord on top of the mattress and detach it from the bed frame Once the air has been released from all the cells roll up the mattress and return all items to the Carry Bag for safe keeping A Prior to restarting the system ensure the CPR tag is replaced and both sealing connectors are firmly attached Replace the rapid release handle and firmly connect to the Control Unit Troubleshooting This section provides basic troubleshooting support for the SoftAIR Excellence mattress system Alarm Fault Cause Solution Control Unit does not The Control Unitmay 1 Check the Control Unit is connected to mains power outlet operate no display not be attached toa with the correct voltage lights illuminate power source 2 Check the Control Unit is switched on Afuse may need 3 Check the mains plug fuse 3 AMP then check both replacing in the Control Unit fuses 1 AMP fuses ca
9. he base 4 Ifyour hand can pass under the patient the patient is adequately suspended and pressure can be lowered 5 Repeat the Bottoming Out test after pressure has been lowered In the event of a system malfunction the alarm will activate and pressure LEDs will flash Operation Establishing Pressure inclined position When moving the patient to a more upright position pressure may need to be increased by approximately 20 to provide added support and to avoid bottoming out A Itis important to return to the original pressure setting when the patient returns to the supine position and perform a Bottoming Out test A Wait a minimum of 10 12 minutes between pressure adjustment and patient assessment as it may take a full cycle for the system to adjust to any new setting CPR Function Rapid deflation of the mattress may be required for emergency procedures or to decommission the system Firmly pull the rapid release CPR tag from the side of the mattress to deflate the whole system To re inflate the system after the CPR tag has been removed replace the CPR tag ensuring both sealing connectors are firmly attached and restart the Control Unit Wait for the mattress system to gain optimal pressure Perform a Bottoming Out test after inflating the mattress following rapid deflation Operation Alarm Function The red Alarm LED will flash and an audible alert will sound to indicate the c
10. ing on the cause of the failure On the side of the control unit are four male air connectors for connecting the handle The rapid release handle includes a cap which can be inserted into the handle during transportation When in transportation mode tests have proven that the system will stay inflated for up to 30 hours with no significant loss of pressure Whilstin transportation mode the mattress will remain in static mode i e cells will not alternate For this reason Invacare recommend that the alternating mode is resumed once transportation is complete The mains supply to the Control Unit can be easily disconnected and is designed to detach if tugged too hard protecting the internal wiring Product Overview SoftAIR Excellence The SoftAIR Excellence Mattress comprises of 19 high density cells which all feature a permanently inflated internal cell to prevent the patient bottoming out in the event of low pressure due to incorrect settings electrical or cell failure This system includes three static head cells to provide static pillow support for optimum user comfort while air pressure in the other 16 cells is alternated over a 10 12 minute cycle This provides regular periods of pressure reduction to aid blood and lymphatic flow to vulnerable tissue The SoftAIR Excellence also includes an independent heel zone of five low pressure micro cells for individualised therapy to this sensitive area In addition
11. n be released using a Control Unit screwdriver to push and turn A Do not try to open the Control Unit Opening the unit could cause personal injury or equipment damage A Ensure the replacement of fuses is carried out in accordance with local legislation AlarmLED Initial failure 1 Reset the alarm turn off Power and press the Alarm Mute 2cceEREE audible alarm button Check the handle is intact ensuring all four sealing connectors are firmly fitted to the Control Unit and the air hoses Check the CPR tag is attached and both sealing connectors are firmly secure 3 Check all air hoses along the inside of the mattress each should be firmly connected Check each air cell is securely attached to its connecting air pipe 4 Check all cells pipes and hoses for any air leakage 5 Switch on Power Alarm LED Pressure too low 1 Resetthe alarm tum off Power and press the Alarm Mute B eae 2 Check the handle is intact ensuring all four sealing audible alarm i P connectors are firmly fitted to the Control Unit and the air hoses Check the CPR tag is attached and both sealing connectors are firmly secure 3 Check all air hoses along the inside of the mattress each should be firmly connected Check each air cell is securely attached to its connecting air pipe 4 Check all cells pipes and hoses for any air leakage 5 Check that the air filter cover is correctly secured and the air filter is clean 6 Switch
12. of Operation Non continuous Operating Environment Air humidity 30 to 70 Ambient temperature 10 C to 40 C Storage Transportation Air humidity 10 to 70 Environment Ambient temperature 10 C to 60 C NOTE All product specifications are subject to change without notice Warranty Information Invacare Ltd warrants each of its products to perform in accordance with established specifications for the following time periods starting from the date the productis shipped from Invacare Ltd Control Units 2 years Soft Goods 2years During the warranty period Invacare Ltd either directly or through its distributors will repair or replace at no charge any products that are not performing in accordance with established specifications unless the problem failure is due to customer damage negligence and or misuse unauthorised repairs Items not covered under warranty include but are not limited to stains punctures cuts damages to electrical cords rips or tears dents and or lost missing parts All products returned for warranty repairs must be assigned a Return Autho risation Number prior to return Returns should include information describing the problem and or requested repair and be sent to your local Invacare Ltd sales office by prepaid transportation Invacare Ltd will return the repaired replaced product at no charge Warranty repairs do not extend the length of the warranty period Neither Invac
13. om the electrical socket on the side of the Control Unit 3 Insert a small flat head screwdriver into the groove and turn anti clockwise 1 4 turn 4 Remove the blown fuse from the fuse holder clip and discard 5 Insert anew fuse into the plug Push against the force of the spring and turn clockwise with the screwdriver 1 4 turn A Ensure the replacement of fuses is carried out in accordance with local legislation Technical Specifications SoftAIR Excellence Cycle Control Purpose designed distributor valve supplying operating air to the inflatable cells Cycle Time 12 minutes Supply Voltage 220V 50Hz 0 2A for Control Unit IP Rating IP41 Fuse Rating 1AMP x1 Battery Source VARTA V80H 1 2Vdc 70mAh Power Rating 12VA Standards CE No of Cells 19 cell in cell including 3 static head cells and 5 micro cells plus 2 side bolsters Cell Height 230mm Maximum Patient Weight 180kg Product Life Cycle 2 Years Mattress Dimensions Length 2000mm Width 830mm 880mm Height 250mm including side formers Weight 9 5kg 10 8kg Control Unit Dimensions Length 290mm Width 170mm Height 270mm Weight 3 2kg Cell Material 0 15mm TPU film laminated on 210 denier nylon fabric Base Material Nylon fabric 420 denier with a 0 1mm TPU coating Cover Material 100 Polyurethane surface 100 polyester inside Hose Connection Push on connection Handle Emergency CPR Tag Mode
14. on Power Alarm Fault Cause Alarm LED Pressure too high c08888HA audible alarm Troubleshooting Solution Reset the alarm turn off Power and press the Alarm Mute button Disconnect the air hoses to reduce pressure reconnect when pressure has decreased Check for twists in the air hoses between the mattress and Control Unit Switch on Power Alarm LED Alternating Pelee Mode Failure a no alternation audible alarm Reset the alarm turn off Power and press the Alarm Mute button Disconnect the air hoses to reduce pressure reconnect when pressure has decreased Alarm LED AC power failure c088888A audible alarm Press the Alarm Mute button to silence the audible alarm Check the power cable is firmly plugged into the mains outlet and the Control Unit and check the mains power is switched on Check the Control Unit fuse 1 AMP fuse can be released using a screwdriver to push and turn Patient is sinking or The pressure may bottoming out whilst lying be set too low for the flat on the mattress patient s weight Increase the pressure setting by pressing up the Pressure arrow To check effective system performance conduct a Bottoming Out test as described on page 9 Ifthe problem is not resolved please contact your local Invacare Ltd sales office Maintenance amp Cleaning Infection Control and routine cleaning must be car
15. ontrol unit or mattress pressure has failed The LED will remain illuminated until appropriate pressure is restored The audible alarm can be silenced by pressing the Alarm Mute button The system has five different alarm signals which can be identified by five different Pressure Setting illumination sequences The signals and corresponding Pressure Setting LED displays are illustrated below Display Alarm Signal mae Initial Failure Mattress has failed to reach minimum operational pressure within 50 minutes ERA Low Pressure Pressure has fallen 5mmHg or more below the setting minimum HA High Pressure 202884 Pressure has exceeded the maximum setting by 10mmHg or more Alternating aces Mode failure Mattress has failed to commence alternation No pressure output due to mains power failure Ifthe alarm activates and the system fails to inflate or loses pressure please refer to the Troubleshooting section on the following pages Transport Function 1 Prior to transport switch the mode from alternating to static and wait five minutes for the cells to inflate to maximum pressure 2 Turn off the Control Unit and remove the rapid release handle from the Control Unit 3 Allow air to escape for a couple of seconds before sealing with the attached transport cap This will soften the mattress surface for pressure relief and comfort If the patient is responsive question their comfort l
16. ried out in accordance with your local Infection Control Policy It is suggested that all disinfection be done with a high grade disinfectant such as Sodium Hypochlorite or similar up to 10 000 ppm available chlorine A The top cover seams are sealed to prevent moisture ingress and bacterial growth in the seam stitching A Do not use high temperature autoclave or Phenolic based products for cleaning A Itis recommended the system is cleaned between patients and approximately every two weeks if in constant use Mattress Top Cover If there are visible signs of body fluids and or substances present the top cover should be washed Top covers can be machine washed up to 95 C using disinfectant such as Sodium Hypochlorite or similar up to 10 000 ppm available chlorine To establish the amount of disinfectant to use determine the amount of water in the washer and then follow the manufacturers instructions for dilution Soak the top cover in the disinfectant during the wash cycle Rinse well in clean water and dry thoroughly before use A Do not dry the top cover using the heat cycle or a dryer Please air dry or select a non heat dry cycle If there are no visible signs of body fluids and or substances on the top cover the top cover should be sanitised 1 Apply an intermediate level disinfectant or a solution of Sodium Hypochlorite or similar up to 10 000 ppm available chlorine to the top cover
17. risk assessment must be performed by a suitably qualified person especially when side rails are prescribed to ensure the bed meets the new IEC 60601 2 52 bed standard A Arisk assessment must be undertaken when looking to place additional items between the mattress surface and patient A To ensure the alternating cells move effectively secure the bed sheets loosely around the mattress en Oa oS gt soften Control Unit A The control unit is tested and approved according to ISO EN 60601 1 rev 2 amp EMC A Only plug into a grounded power outlet and use the power cord supplied with the system A Exposure of the electronic Control Unit to any liquid while it is plugged in could result in a severe electrical hazard A Always use fuses of the same rating as specified in the Technical section Using fuses with higher ratings could result in damage and or injury A The electronic Control Unit is a precision electronic product Handle and transport with care Dropping or other sudden impacts may result in damage to the unit A Do not open the Control Unit due to risk of electrical shock Do not attempt to repair or service the Control Unit A Do not place any objects or items such as blankets on or over the Control Unit A The power cord to the Control Unit should be positioned to avoid a trip hazard and or damage to the cord Careful consideration is required when routing the power cable Invac
18. upper surface either by spraying or by hand application 2 Ensure the surface is completely covered with the disinfectant and remains in contact with the surface according to manufacturer s instructions 3 Remove disinfectant and rinse thoroughly 4 Allow to air dry before use Mattress Base Wipe down the outside shell with disinfectant or a solution of Sodium Hypochlorite or similar up to 10 000 ppm available chlorine ensuring that all surfaces come in contact with the disinfectant Rinse off well with a clean damp cloth and air dry Should the air cells require disinfecting disconnect the air cells from the base by unfastening the press studs at each end and disconnect the air pipes from the main air hoses before sliding each cell out from the cell straps Swab with a solution of Sodium Hypochlorite or similar up to 10 000 ppm available chlorine Dry thoroughly with a soft cloth before refastening A Do not machine wash or dry the air cells or mattress base A Do not disassemble the mattress unless cleaning is required If cleaning or disinfecting is required do not disconnect the pipes from individual Air Cells Handle The exterior of the Handle can be periodically wiped using a cloth dampened with disinfectant Control Unit A Ensure the Control Unit is disconnected from the mains electricity supply before cleaning A Do not spray disinfectant directly on to the Control Unit or immerse
19. verts back to the previous pressure setting for patient safety G Control Unit Lock Unlock Button Press for at least two seconds to lock the Control Unit settings Abeep sounds and the amber LED illuminates to indicate system is locked When locked only the Alarm Mute and Lock Unlock buttons remain operational Press again for at least two seconds to unlock Again a beep sounds and the amber LED turns off A The Control Unit will automatically unlock in the event of a power failure Mattress Function Establishing Pressure supine face up position Once the patient is in place use the Pressure button to select the best setting for effective pressure relief and support based on the patients weight and comfort requirements Assess whether the patient is comfortable and the system is functioning correctly by performing a bottoming out test Bottoming Out Test When altering the pressure setting ensure the patient is not bottoming out insufficiently supported by the air cells and therefore coming in contact with the bed base 1 Ensure system is in alternation mode but is not undergoing an alternation 2 With the patient lying in a supine position unzip the top cover just past the sacral bottom region 3 Slide your hand along a deflated cell under the patients sacral area bottom The inner static cell will remain inflated but your hand should slide easily between the patient and t
Download Pdf Manuals
Related Search
Related Contents
25 years SIS from Bosch: The Troubleshooting device オプション部品 取扱説明書 Indesit DV 62 Dishwasher User Manual Audiovox AH630R mobile device charger clique para ver o manual de montagem Transferir I IIIIIIIIIIIIIIIIIIII Mode d`emploi, Instruction JURA IMPRESSA Z5 *340607* 340607 Copyright © All rights reserved.