1. Remove dust or any kind of other dirty from the fans and loop holes to ensure the correct air flow Remove dust lenses using a cleaning cloth This will ensure the maximum light efficiency Replace damaged protection screen and lenses when necessary Do not touch nor clean the LED as wil the yellow area around it with solvent Device disposal information At the end of its life HPLed must be disposed to an appropriate electrical and electronic equipment waste collection centre Eco friendly disposal helps to avoid possible negative impact on the environment and human health and promotes the reuse and or recycling of the materials making up the product Illegal disposal involves administrative sanctions provided by laws enacted Manufacture declines any sort of personal corporate responsibility liability for damages caused by the inadequate misuse of the product as well as if the product has been handled by unqualified personnel Not complying with security norms periodical maintenance as expressed in the owner s service manual will also totally free personal corporate responsibility liability Preliminary Any changes can be brought without notice HPled 05 03 2013 rev 00 UK
2. Do not handle HPLed with humid hands or near to any water or any kind of moisture sources IP20 protection rating HPLed is rated Class I Earth connection is mandatory CE Approvals HPLed meets EMC 89 336 CEE 92 31 CEE BT72 23 CEE 98 68 CEE requirements HPLed complies with EN50419 Rohs and 2002 96 EC WEEE norms Technical specifications Power Supply Maximum power consumption cos Stand by power consumption Minimum ambient temperature Maximum ambient temperature LED Colour Temperature availability LED CRI LED Life Manufacturer specification Weight IP Rating Working position Power connectors Data connectors Data protocols User interface compliant Dimensions see picture 100 240 V 50 60Hz 170W 0 98 5W 10 C 35 C 2700 k 3000 K 4000 K 5000 K to specify when ordering Minimum 80 based on 2700 k 3000 K 4000 K models Minimum 65 based on 5000 K 50 000 hours 2 03 Kg IP20 Any IN amp OUT Neutrik PowerCon IN amp OUT XRL5 DMX 512 RDM 4 digit display and 4 buttons HPLed installation HPLED has been designed to be installed in any ETC source 4 fixtures to give the equivalent of traditional HPL575 750 source It is essential to remove some parts of existing ETC source 4 fixture 1 2 3 10 11 Fig 1 Fig 2 Disconnect any kind of power source that could cause electric shock Loo
3. HPLED Owner s and service manual Read this manual totally and carefully follow all the instructions contained File this manual for future use It is essential to read all the information contained to ensure installation service and full operation of the HPLed All operations must be accomplished handled and carried out by qualified personnel only NOT COMPLYNIG WITH GIVEN NOTICE WILL VOID WARRANTY AND WILL FREE THE MANUFACTURER OF ANY SORT OF RESPONSABILITY AND LIABILITY Unpacking Unpack the carton and gently remove HPLed from the box Ensure HPLed it s integer from origin in all its components In the event the HPLed shows any damage do not use it and contact immediately your transporter as well your seller Items in the carton consist of HPLED Module Rear metal cover with input connections Blue Neutrik PowerCon connector This owner s manual Safety information HPLed must be installed on original ETC source 4 fixture only Any other use will void warranty and will free the manufacturer of any sort of responsibility and liability Minimum distance from any flammable source is of 0 5m Minimum throw distance from illuminated surface 0 5m Power HPLed to safety circuit breaker Maximum ambient temperature 35 C Warning from electric shocks All operations must be accomplished handled and carried out by qualified personnel only Disconnect power before servicing
4. ailable DMX off line when led is off HPLed Power ON WARNING Before powering HPLed ensure that all installation s procedure s have s been properly set and accomplished When HPLed is powered the setup display will show the software release version Using the 4 UP DOWN ENTER and ESC buttons will be possible to operate the HPLed menu UP and DOWN buttons allows you to scan menu options ENTER button to select and ESC button to back to previous menu option cancelling the modification applied to the selected one Menu items Message values 001 510 SetUp DMX Address Addr 2 ch ach DMX Operati d 4ch perating mode see next page 5ch dut Manual light output adjust possible if no DMX is present 0 255 Adjusted value will be stored on the internal permanent memo aC Shows driver operating temperature LEdt Show led operating temperature PUM k 0 100 Shows current led power 0 100 LInE Dimmer profile selection qUAd LinE for linear dimming regulation qUAd for tungsten lamp emulation Off Boost selection o off maximum led power at 90 on maximum led power at 100 AA Display orientation selection Ww AA normal VV inverted Standby display activity off display always switched on on display switched off after few seconds of buttons inactivity only the right side dot will be lighted to indicate ON Will restore the default factory values Shows LED life S
5. any contact interference interconnections interpositions with fans and other interfering components that might collide squeeze hamper the correct operations Remount the rear metal cover to the Source 4 body using any 10mm spanner by tightening the screw to its full extent Do not exceed nor force tightening Connection to mains WARNING Installation s must be accomplished handled and carried out by qualified personnel only and must comply with all norms in force in the installation s country HPLed is supplied with a free Blue Neutrik PowerCon plug that must be wired using a 3x1 5mm2 lead which additional specifications include Operating Voltage 300 500V Test Voltage 2KV Operating Temperature 10 C 90 C Connect blue wire to N terminal brown wire to L terminal and Yellow Green wire to earth terminal Ensure safety circuit breaker at all times Daisy chain of up to 10 units when connected to 230VAC Daisy chain of up to 5 units when connected to 110VAC Maximum daisy chain length 20m WARNING HPLed CANNOT be powered by using an angle phase dimmer pack Control signal connection Fig 6 HPLed can be cooperated via either DMX512A and or RDM Protocols Daisy chain DMX line using a 2 lead wire plus shield DMX XLR 5 Pin Assignment Pin Description 1 GND DMX DMX Not connected mi AIIN Not connected Reed led blinks when DMX Input av
6. hows HPLed life Shows Software version DMX Operating Modes Mode HPLed provides different DMX operating modes ensuring the ideal use of the DMX universe 2ch Mode DMX Values shutter We he 10 255 Strobe effect from slow to fast 0 255 Light output 0 0ff 255 Maximum Power 3ch Mode DMX Values PR shutter 2 2 dimmer 0255 Light output 0 Off 255 Maximum Power _ Ea Fan speed 4ch Mode DMX Values PR shutter 29 2 dimmer 0255 Light output 0 Off 255 Maximum Power _ ce Fan speed Frequency PWM Frequency 1KHz Modulation 5ch Mode shutter 22 ft 2 DimmerCoare 0 255 Lightoutput 0 0ff 255 Maximum Power Coarse 3 Dimmerfie 0255 Light output 0 Off 255 Maximum Power Fine Fan speed Frequency Modulation 100 124 PWM Frequency 5KHz 125 149 PWM Frequency 6KHz 150 174 PWM Frequency 7KHz 175 199 PWM Frequency 8KHz 200 224 PWM Frequency 9KHz 225 255 PWM Frequency 10KHz Error messages In case of malfunction the following messages can be shown HP Fan Error means problems on 40x40x10 fans LED Fan Error means problems on 80x80x10 fan Should any of the above given messages occur the LED will automatically switch off Refrain and halt the use of the HPLed and promptly contact any authorized service centre Periodic maintenance To ensure the correct HPLed operation we suggest the following periodic maintenance operations
7. sen knobs that hold lens assembly remove it and place it aside in a safe place Locate rear section of the Source 4 fixture then start loosening knob that hold the round plate in place until it is totally separated from the main body You may either store or scrap this part As of now onwards for your own safety we recommend you must wear protection gloves and safety transparent goggles Locate the Source 4 inner reflector and start removing it from its housing as shown in the Source 4 Assembly guide Place HPLed on working bench and start loosening the 3 M4 screws that hold the metal ring marked by red arrow in figure 2 Insert HPLed in the Source 4 body ensuring the correct inward direction is followed as marked by the 2 red round ring references and by the red arrow as shown in figure 3 During such operation make sure that the 3 connecting cables i e power cable dmx cable and display cable are led through loop holes of the case ensuring that they will not be squeezed during reassembling Remount the metal ring to its former position by tightening the 3 provided M4x6 screws to their full extent Do not exceed nor force tightening Connect the 3 lead cables to the rear metal cover provided ensure that connectors are inserted in the correct side Special attention must be given to the flat cable as it must be handled with extreme care while connecting its end Ensure that all cable connections are neatly and clearly cut set to there position avoiding
Download Pdf Manuals
Related Search
Related Contents
User-Manual VSpace-Server-7.0 PE440BU - Pioneer Eclipse C 4/36-90 / C 4/36-350 M900S™ 900 MHz Wireless Broadband System USER MANUAL SOYO Computer Hardware Motherboard User's Manual 200W Solar Charger Maximum Power Point Tracker MXCTSL User Manual - AMETEK Programmable Power RTM User Manual - Newport Corporation Copyright © All rights reserved.