Home

Installation Manual

image

Contents

1. THERM SENSE P1 Temperature Sensor 1 3 5 RS485_ RX P 7 RS485 RX N Serial Interface 2 AG MEE Serial Interface 1 11 RS232_ RTS m 13 GPO 0 Open drain IS ero High max Vin 5mA 17 GND_IN DC 19 PVIN DC Pin Assignment X18 Pin Signal Description 1 Relay1 220VDC 250VAC 2A max 2 no fuse input fuse necessary 3 220VDC 250VAC 2A max Relay 2 l 4 no fuse input fuse necessary TRUST EMTrust GmbH 85258 Weichs Gewerbering 1 computers you can trust Pin Assignment X19 Pin SUEI Description 2 THERM_SENSE_P2 Temperature Sensor 4 PWM_OUT OD High max Vin 5mA 6 RS485 TX_N l 8 RS485 TX P Serial Interface 2 10 R8232 RXD l 12 RS232 CTS m Serial Interface 1 14 GPI_O Low max 3V 16 GPI_1 High max Uin 18 CAN _P l 20 CAN N High speed CAN 1Mb s 2015 EMTrust GmbH All rights reserved Pin Assignment AN ROX 3 5 Display System Connecting different Tempera ture Sensors e Thermocouple 2 wire e Pt100 1000 3 wire e Pt100 1000 2 wire computers you can trust EMTrust GmbH 85258 Weichs Gewerbering 1 ANDROX t P Thermo couple 2 wire Pt100 1000 3 wire tts Pt100 1000 2 wire tts Temperature measurements interface Connector X19 Temperature Sensors Before connecting the sensor ple
2. during transport EJ TRUS EMTrust GmbH 85258 Weichs Gewerbering 1 t computers you can trus This protective package should be environ mental friendly recycled after use Disposal of Device At the end of the lifetime please dispose ef and or recyle the components of the device accordingly Table of Contents 1 General Information 2 2 Table of Contents 5 3 System Information 6 4 Symbols Regulations Purpose T 5 Scope of Delivery 8 6 Frame Assembly 9 7 Rail Mounting 10 8 Electric Connectors 11 9 Pin Assignment X18 and X19 12 10 Temperature Sensors 13 11 Technical Data 14 12 Terminology 15 2015 EMTrust GmbH All rights reserved Table of Contents AN ROX 3 5 Display System Required Tools For the installation of the ANDROX system the following standard tools are recommended 1 Frame assembly Tools for measuring mar king and cutting out Torx screwdriver T9 2 Rail mounting Torx screwdriver T9 3 Cable connection Slot screwdriver blade width 2 5 mm Other required tools are depending on the ins tallation place and method External Notice All external documentation to install the ANDROX system should be obeyed TRUST EMTrust GmbH 85258 Weichs Gewerbering 1 computers you can trust Software and Support A pre configured Android system is available on microSD card from EMTrust For more information how to buy it please con tact sales emtru
3. hat rail when using the optional holder Please follow the in structions below e Mount the hat rail holder at the back of the ANDROX system with 2 screws M3 x 8mm The hat rail holder is suitable for TS 35 type hat rails Rail Mounting Placing the system on the hat rail e Put the system on top on the hat rail Swivel it inwards until it snap securely Removing the system from the hat rail e Push the system upwards from the bottom Swivel it outwards and take it off 2 Swivel and lt 4 snap 3 Push upwards ISSA EMTrust GmbH 85258 Weichs Gewerbering1 10 computers you can trust 2015 EMTrust GmbH All rights reserved AN ROX 3 5 Display System Operating Elements and Interfaces 1 TFT Touchscreen 3 5 2 LAN Ethernet 10 100 1000 Mbits s RJ45 3 e lt gt USB 2 0 Type A female connector Host Port 4 microSD 2 0 Card Slot 2x 4 1 Slot 1 operating system 4 2 Slot 2 optional data 5 HDMI 1 4 6 No use 7 X19 IO connector for temperature sensor RS485 RS232 CAN GPIO PVIN PWM Power 8 X18 2x Switch Relay 9 e USB 2 0 Mini B female connector on the go 10 ON Switch System switch on off TRUST EMTrust GmbH 85258 Weichs Gewerbering 1 computers you can trust 2015 EMTrust GmbH All rights reserved Electric Connectors AN ROX 3 5 Display System Pin Assignment X19 THERM _ SENSE N Description
4. Installation Manual isplay System m in m 2015 EMTrust GmbH All rights reserved TUSI EMTrust GmbH 85258 Weichs Gewerbering 1 computers you can trust ANROX 3 5 Display System Manufacturer EMTrust GmbH Gewerbering 1 D 85258 Weichs E Mail androx emtrust de Web www emtrust de Phone 49 8136 80 677 809 Digital unterschrieben von Version 04 2015 Rev 2 1 Crrsta 0200 EM TRUS EMTrust GmbH 85258 Weichs Gewerbering 1 t computers you can trus General Notes This User Manual is for your information The information contained herein has been checked carefully and is believed to be reliable However EMTrust gives no guarantee or war ranty concerning the accuracy of spoken in formation and shall not be responsible for any loss or damage of any nature resulting from the usage of or from reliance upon it We are thankful for all suggestions or impro vements at any time EMTrust reserves the right to make changes in the products or specifications or both at any time without notice Copyright Notice Copyright 2015 by EMTRUST GmbH ALL RIGHTS RESERVED EMTrust GmbH copyrights this document You may not reproduce transmit transcribe store 2015 EMTrust GmbH All rights reserved General Information AN ROX 3 5 Display System in a retrieval system or translate into any lan guage or computer language in any form or by any means
5. ase check its electric specification i e maximum current and configure the application accordingly An incorrect configuration can destroy the sensor Sensor Measuring range Type K 270 to 1370 C Pt 100 200 to 870 C PT1000 200 to 870 C 13 2015 EMTrust GmbH All rights reserved Vays 3 5 Display System Technical Data e 3 5 TF T display with resistive touch sensor touch screen and LED backlight e Resolution 320x240 Pixel 24Bit RGB e Luminance typical 320 cd m e Processor Freescale i MX 6Solo 800MHz e RTC Realtime Clock with battery backup Battery lifetime min 5 years e Memory 1GB DDR3L RAM 800MT s e 2x microSD 2 0 card slot Mass storage e Graphics Output HDMI 1 4 Maximum resolution 1920x1080 60HZz e Ethernet 10 100 1000 Mbit s Gbit Ethernet is li mited to maximum 480 MBit s e USB 2 0 Type A female connector Host Port e USB 2 0 Mini B female connector on the go Cli ent Port e Serial Interface RS232 4 pin for TxD RxD CTS and RTS and RS485 e CAN Interface FlexCAN up to 1Mb s e Interface for temperature sensors e g RID and EM TRUST EMTrust GmbH 85258 Weichs Gewerbering 1 computers you can trust 14 Thermocouple e PWM Output OD High max Vin 5mA e Digital Input and Output 2x IN and 2x OUT e Switch Relay max 220VDC 250VAC 2A e Power Supply Nominal 12 24 VDC 8 V min to 28 V max e Ambient temperature 0 C to 60 C e S
6. icy of EMTrust to respect the valid pa tent rights of third parties and not to infringe upon or assist others to infringe upon such rights EMTrust assumes no responsibility for circuits descriptions and tables within this document as far as patents or other rights of third parties are concerned 2015 EMTrust GmbH All rights reserved General Information AN ROX 3 5 Display System Life Support Applications EMTrust s products are not intended for being used as critical components in life support ap pliances devices or systems in which the fai ling of an EMTrust product could be expected to result in personal injury FCC and CE Disclaimer EMTrust gives no warranty at all that their pro ducts will meet the FCC and CE standards when used in combination with other third party products or when used in any other way than specified Limited Warranty This product will be free from defects in work manship and material under normal and proper use for the period of time defined in our Gene ral Terms of Business effective the date of the original shipment from EMTrust GmbH EM TRUS EMTrust GmbH 85258 Weichs Gewerbering 1 t computers you can trus _4 In the event of a warranty claim for defects which appear within the warranty period custo mer shall deliver the product along with proof of purchase to the original place of purcha se shipping prepaid Repair replacement or refund of the purchase p
7. ng the installation please check the completeness of your delivery 1 ANDROX system 2 20 pole plug grid 3 5 3 4 pole plug grid 3 81 4 2x Holder for frame assembly 5 2x screw M3X10 6 Gasket 95 4x95 4x2 mm 7 Installation and user manual 8 MicroSD card option 9 DIN rail holder option Scope of Delivery Lined EMTrust GmbH 85258 Weichs Gewerbering1 8 2015 EMTrust GmbH Alll rights reserved computers you can trust AN ROX 3 5 Display System Frame Assembly Depending on the type of installation and the space available it could be necessary to insert the microSD Cards and estab lish all connections in advance For further information please see the operation manual For frame assembly wall strengths of 1 5 mm to 6 mm are supported The torque for fas tening is 0 35 Nm We recommend the following procedure 1 Cut out an area of 92 mm x 92 mm 0 8 0 0 mm 2 Add the gasket to the system frame 3 Place the ANDROX system in the cut out area 4 Insert the system holders from above The hol ders will stay in place at the middle of the sys tem 5 Fix the system with two screws M3x10mm to the frame computers you can trust EMTrust GmbH 85258 Weichs Gewerbering 1 s0 2015 EMTrust GmbH All rights reserved Frame Assembly AN ROX 3 5 Display System Rail Mounting optional accessory The system can be mounted on a
8. or otherwise any part of this pub lication without the express written permission of EMTrust GmbH Trademark Acknowledgement EMTRUST is a registered trademark of Tru comp GmbH Android is a registered trade mark of Google Inc Yocto Project is a regis tered trademark of Linux Foundation Qt and the Qt Logo are a registered trademarks of Digia Plc and or its subsidiaries All rights reserved All other mentioned trade marks are registered trademarks of their ow ners Disclaimer This document is provided for the general in formation of the customer It describes the ge neral functionality of the system and is not con EM TRUS EMTrust GmbH 85258 Weichs Gewerbering 1 t computers you can trus so sidered as assured characteristics The written declarations in this specification are not consti tuent part of any contract EMTrust reserves the right to modify the infor mation contained in this manual as necessary and the customer should ensure that he has the most recent revision of this document EMTrust makes no warranty for the use of its pro ducts and bears no responsibility for any errors which may appear in this document The custo mer should be on notice that the field of personal computers is the subject of many patents held by different parties Customers must ensure that they take appropriate action so that their use of the products does not infringe upon any patents It is the pol
9. rice of the defective product will be at the sole option of the manu facturer All transportation risks and costs in connection with warranty service are the res ponsibility of the customer THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLU DING WITHOUT LIMITATION IMPLIED WARRAN TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ANY CUSTO MER CONSUMER END USER PURCHASER OR OTHERWISE IN NO EVENT SHALL MANU FACTURER BE LIABLE FOR LOSS OF PROFITS INDIRECT SPECIAL INCIDENTAL OR CONSE QUENTIAL DAMAGES ARISING OUT OF ANY BREACH OF CONTRACT OR WARRANTY NEG LIGENCE STRICT LIABILITY OR OTHERWISE 2015 EMTrust GmbH All rights reserved General Information AN ROX 3 5 Display System The remedies for defects in this product are li mited to those set forth above If this limitation of remedies is held by any court to be void or unenforceable or if no warranty is made ma nufacturers liability shall in no event exceed the purchase price of the product giving rise to the claim regardless of whether such claim is brought in breach of contract or warranty neg ligence strict liability or otherwise Reshipment If you return the ANDROX system to EMTrust please remove all connections and peripheral equipment Protect the unit through a suitable packaging preferably use the original packaging Packaging The ANDROX system is in a protective packa ge to avoid damage
10. st de For technical support contact androx em trust de 2015 EMTrust GmbH All rights reserved System Information AN ROX 3 5 Display System Install and Connection Regulations The current safety regulations at the pla A ce of installation as well as all other mea sures of safety must be applied Do not apply power to the device for the duration of the installation The connector X18 is able to handle vol tages up to 250VAC or 220VDC If volta ges higher than the maximum supply vol tage of the device 8 28VDC are used at this connector the connection must only be made by professional experts Used Symbols Marks warnings which you should fol low for your own safety and the safety of others The attention to those warning notices preserves the ANDROX system from damages EM TRUS EMTrust GmbH 85258 Weichs Gewerbering 1 t computers you can trus sTo Provides information for the optimum use of the ANDROX system Purpose ANDROX is a 3 5 touch screen system for low voltage range It was designed for the ins tallation in a switchboard or frame The front si de is IP65 protected The main field of use is the supervision mea surement or control of objects and peripheral devices as well as the storage and transfer of information 2015 EMTrust GmbH All rights reserved Symbols Regulations ayi4 3 5 Display System Scope of Delivery Before beginni
11. torage temperature 20 C to 80 C e Humidity non condensing lt 75 e Dimension approximately 96x96x47 mm e Weight approximately 300 g Technical Data 2015 EMTrust GmbH All rights reserved ays 3 5 Display System Terminology AC Alternating Current CAN Controller Area Network Serial Network COM Serial Communication Port Serial Interface CPU Central Processing Unit DC Direct Current DDR3 Third generation Double Data Rate SDRAM storage technology EMI Electromagnetic Interference Gigabit Ethernet Ethernet connection with a transfer rate up to 1000Mbit s GND Chassis ground GPIO General purpose input output Host A network host or other device connected to a computer network HDMI High Definition Multimedia Interface IP65 Dust tight and water jets protection LAN Local Area Network LED Light Emitting Diode MicroSD Memory card format 11x15x0 7mm PWM Pulse Width Modulation RTD Resistance temperature detector e g PT100 RS 232 Recommended Standard 232 TRUST EMTrust GmbH 85258 Weichs Gewerbering 1 computers you can trust RS 485 TFT TSP USB Recommended Standard 485 Thin Film Transistor Touch Screen Panel Universal Serial Bus Terminology 2015 EMTrust GmbH All rights reserved EM TRUST computers you can trust

Download Pdf Manuals