Home

LHD8003 Installation Manual

image

Contents

1. Refer to page 21 22 When WL Device triggered panel send alarm SMS dial the voice receiving number Disarm the panel please see page 10 41 Menu Structure Abbreviation Description Temp Temporary Trb Trouble Auto Time Auto Arm DisarmTime WL Wireless Comm Communication Supp Ent Delay Supplementary Entry Delay See Page 39 Output Trigger Conditions for PGM Output PGM Cut off PGM Output Time Clear Users Clear User Codes Del Delete Superv Supervision SV Supervision CMS Central Monitor Station SMS Message Zone Trb Ind Zone Trouble Indication Call Back Siren Call Back for Confirm Dis Disarm Reg Register En Ex Entry Exit Per Perimeter Line Loss Telephone Line Loss TX Transmitter Interface Dialing or SMS Interface like PSTN or GSM Auto ON OFF Auto Arm Disarm ON OFF Wired Test Wired Siren Test WL Test Wireless Siren Test Built in Test Built in Siren Test Clear WL Clear Wireless Transmitters Clear Single Clear Single Transmitter Clear All Clear Al
2. Table 2 Zone Type 2 During input press to quit When finished press to confirm Or if the time is not input Zone Valid or not Valid or not Valid or not Exit Entry Sound Mount position Type completely but with ending It will indicate Invalid set Then pres to re input Type when disarm when away when stay Delay Delay and flash or detector number Entry Exit Invalid Valid Valid Yes Yes Yes Gate 01 Auto Arm Disarm Time Active lavalid Valid fnwaiid Yes Vos Vas indoor 02 It enables users to set auto arm disarm time which is set in 24 hr system Before this the function of auto l l arm disarm must be turned on Perimeter Invalid Valid Valid No No Yes Veranda window 03 To set auto arm disarm time Panic Valid Valid Valid No No Yes Panic button 04 1 Select Arm time or Disarm Time press to enter input time and press to save Fire Valid Valid Valid No No Yes Fire detector 05 i i l To turn on off the function of auto arm disarm Gas Valid Valid Valid No No Yes Gas detector 06 i wig 1 Select Auto ON OFF press Tamper i i i Tamper switch 07 p Valid Valid Valid No No Yes p 2 Press 17 O O to select ON or bk OFF a ending with EHT Duress Valid Valid Valid No No No Emergency button 08 3 Press to quit when finishe
3. 2 The system will disable without power 3 Alarm warning devices such as bells may not alert people if they are installed in an improper position If the alarm bell is installed outside there are less likely to waken or alert people inside the bedrooms Telephone line used to transmit alarm signals may be out of service for any reason or cannot perform communication normally for vicious attack Unsuitable installation position of detectors If smoke detector is installed in an improper position it is not easy for smoke to enter the detecting area Because of doors or walls it is hard for the detector to detector fires in other rooms e g the detector in the first floor cannot sense fires in the second floor Lack of maintenance may lead to the system disabled Weekly testing is necessary to ensure the system work normally 37 s Parameters General Parameters Wireless zones 32 Wired zones 2 EOL resistance 2K 2 4K Wireless frequency 433MHz 868MHz Detector Magnetic contact Keyfob wireless distance 100m with no obstacle Siren wireless distance 50m with no obstacle PSTN way DTMF Communication protocol Contact ID Dimension 250 150 45mm Electric Parameters Power adaptor Input 100V 240VAC 50 60HZ Output 12VDC 1 5A Backup battery capacity 7 2V 1800mAh Working voltage 12VDC Static current lt 90mMA 12V not including wired detectors and GSM module AUX power output AC10 12V
4. Send for Service Info is closed the info will not be sent during enter or quit programming or zone bypass It will send all events as default Panel ID ID can be set for each control panel so that the CMS can identify Different ID must be set for different control panels which is 4 6 8 digits A F utmost with default as 1234 A ID is 4 digits as factory default And 6 8 digits are for customized order Users can set the ID in Note this way Pressing then 0 means A then GF means B and so forth Line Monitor The function of Line Monitor can be on or off If the function is turned on it will display on the LCD 28 gt Arm disarm status check password0808status Reply format p 1234 ID 1234 ID 1234 Prog Arm away Prog Arm stay Prog Disarm Act OK Act OK Act OK A Arm amp disarm is not allowed when programming when zone alarm it will not arm Note meanwhile it will fail and return back Method 2 By using Alarm4Home to send SMS Users need to install Android or IOS Alarm4Home correctly Then operate the alarm system as to the operation hints in the interface Every operation will send a message to the panel App Setting Steps 1 Add control panel s 9m Choose Profile Select Delete Edit Create New Profile ALARM SETTINGS SAVE SETTINGS Click ALARM SETTINGS Click Create New
5. Ce Dya To register by code Input 3 Using System More Details Lin 1 If the code is input before it will remind if users want to re register press to continue or to exit 2 Input the ID ending with 3 The LCD will remind if need change the name Press to confirm Or to quit Display Interface 4 Press to quit Users may meet following symbols or marks Zone Naming Selected for Multiple choice Details refer to the page 20 User Account Naming Unselected for Multiple choice a T Clear WL Selected for Single choice O This enables users to remove the wireless devices by clearance For the supervision function If the device is removed without clearance the system will remind trouble for device loss Unselected for Single choice ees ee Counting down To Clear WL 1 Select Clear WL press select Clear single or Clear All gt gt gt Confirm to enter for details 2 If Clear single select the zone number ending with While Clear all means to clear all enrolled System Trb System trouble wireless transmitters Alarm List Display of alarm events Set Zone Type Trb List Display of trouble For specific zone type definition please refer to page 16 To set zone type Untreated It means not disarmed after alarm 1 Select Set zone type press Treated It means d
6. available from 10 00PM to 7 00AM During trouble query the zone will not alarm with it trigger For detailed system trouble and solution please refer to following table Table 4 Trouble amp Solutions Trouble Solutions Low Battery Check the power connection timely Line Loss Disconnection of telephone line Check the line connection carefully Low GSM signal Weak signal of GSM communication Choose a better position for installation WL Low Battery Low power of transmitters Change battery Trouble Transmitter Loss No signal is received during supervision period Check if the transmitter is moved or broken Wired Trouble Wired devices are triggered Check if the wired devices are normal working or not AC failure Power is cut off Check the power connection timely No GSM module Check the line connection carefully then cut off the power and re connect No SIM card Loose contact of SIM card Please re insert the card after re powering off the panel No GSM signal No signal received from mobile phone SIM card is invalid Or re choose a suitable position for installation Time Unset Re set the system time correctly see page 23 CMS 1 Trouble Failed communication to CMS 1 Note CMS 1 or relatives to check Commu CMS 2 Trouble Failed communication to CMS 2 Note CMS 2 or relatives to check meaton iS Trouble Trouble Failure of SMS send Check if there i
7. DC6 8V lt 100mA Siren output lt 400mA PGM output max load DC 25V 500mA Built in siren 85dB Working temperature 10 C 55 C GSM Module GSM working frequency 850 900 1800 1900MHz RX sensitivity lt 106dB Current Standby lt 25mA RX lt 75mA 236 PGM can connect to wired siren or indicator light Connecting method like following pictures Low voltage device control module pom 2 bev gt External Power GND 7 eee in Figure 4 Setting PGM trigged by programming setting when meet trigged condition PGM connected see Figure 4 A PGM only compatible with low voltage control board It Shall not be connected with city Note power directly Telephone Line Connection Connect the telephone line to the Telephone Line terminal block LINE_IN on the PCB board And then connect the telephone or fax machine to the Telephone Line terminal block LINE OUT See figure 4 1 Users can connect a telephone or non connect a telephone which has no influence to the function LINE_OUT AN Telephone LINE_IN Line slot Figure 4 1 Wired Devices Connection The system supports different kinds of wired detectors with EOL resistance Please connect as following Z1 Z2 21 22 N C detector N O detector ONS z OAC c GND GND Figure 5 Step 4 Power on the control panel Re check the wiring and make sure all connection is correct Connect the AC power adapt
8. fire zone gas zone panic zone duress zone and tamper zone Audio Volume A Note For 24 hour zone whether it is armed or disarmed once triggered it will alarm immediately It enables users to activate or mute the speaker and meanwhile adjust the volume Alarm delay occurs with voice indication as Alarm please disarm when the entry delay zone is Send TEST SMS Interval triggered Before the music ends please disarm and the alarm message will not be sent to CMS center The control panel could be set to send a message at the needed time of each week for testing This testing Or if users disarm after the music the message will be sent Entry delay happens for entry exit zone and message will be sent to all the numbers set before active zone only Version It enables users to query the version of the control panel 1 For entry exit zone only during arm away and arm stay the zone will be triggered with A alarm delay 2 For active zone only during arm away the zone will be triggered with alarm delay Note i 3 When alarm already happens in other zone and with this zone triggered again the panel a 8 Programming will alarm immediately with no indication of entry delay Programming option is only available with installer code Table 1 Different alarm type and zone type determines different alarm way Programming Devices NE teas Berane EI pieome Send SM
9. which can be set 3 Operate control panel from 0 to 30 minutes Armaway Disarm Arm Stay Will proceed the function set above Programming Communication A Each time operates a button it will send out a paid SMS We suggest wait for 30 seconds CMS 1 2 Phone Set Note to proceed next operation after one operation CMS Central Monitor Station is used for event upload through PSTN network including alarm arm amp disarm system trouble and service event log etc of which the phone number can be edited or deleted To set CMS phone Send SMS for Alarm Arm Disarm 1 Select Comm Account ending with Press to select CMS 1 or CMS 2 ending with It enables the control panel to send SMS message D1 DA 2 Then press to select Phone Number to enter with to the set phone number or SMS center for alarm ZONE 002 hall USER 001 lily 3 If any phone number is set already it will display on the LCD Press to input with the icon flash If no or arm disarm For example the control panel ID EVENT i EVENT Ae phone number is set before input directly is 1234 when zone 2 Hall fire alarm it will send 2013 06 ae 2013 08 aan 4 The phone number is 16 digits utmost ending with Press to delete former digit or edit it Press SMS as following to confirm If press directly the former phone number will be deleted
10. as registered If the WL loss Yes No Yes Not ring code is in wrong format it will indicate as wrong If no code is received within 60s the system Low batten fori ees nG T J Netring Note indicate Enrolling failed 16 25 Walk Test It enables users to make sure if the detectors work normally which is strongly recommended to do periodically To set walk test 1 Select Walk test press All registered detectors will display on LCD with the voice guide as Walk test starts transmit wireless signal 2 Once the correspondent signal is transmit the detector display will disappear on LCD If it will not disappear it indicates trouble occurs 3 When all detectors disappear out of LCD the voice will guide Walk test over meanwhile with No device indicating on LCD 4 Press to quit when test is finished Transmitter It includes TX list all registered TX and status report and TX test under this menu TX test is to test and identify wireless signal With signal received from registered transmitter it will display info of it including ID With signal received from unregistered transmitter it will indicate as unknown signal To query TX list 1 Select Transmitter press select Transmitter list press 2 Then the TX list will display Or if with no device it will display correspondently To Test TX 1 Select Transmitter t
11. Code Y beads Dennen After unpacking the kit and making sure that you have all the necessary equipments it is recommended that you ee paul ie install the system as following 110 Fire Alarm 121 Duress Alarm r Step 1 Open the Housing 131 Perimeter Alarm 132 Active Alarm 134 Entry Exit Alarm 137 Panel anti tamper alarm or tamper zone alarm 151 Gas Alarm 301 AC Power Failure 302 Low Battery 351 Line Loss 381 Detector Loss 384 Low Battery for Detector Figure 1 401 Arm Disarm 406 Cancel Alarm Do not plug in power adaptor and rechargeable battery before opening the housing 441 Arm Stay 455 Auto Arm Disarm Failure 521 Mute Siren 570 Zone bypass operation Bypass all or Unbypass all for User 99 Step 2 Insert the SIM 602 Test Report The AC power and battery must be cut off for safe operation Insert the SIM card See Figure 2 627 Programming LOCK gt OUT lt Table 6 Contact ID User Code b T gt User Code Definition RS p EO F p 00 Operation using keypad without user code such as arm away arm stay 01 Arm disarm using master code by keypad phone or SMS 02 Program with installer code Figure 2 03 Duress alarm by user 98 with Disarm indication on site 04 Arm disarm using tem
12. INSTALLATION MANUAL a CREATING SECURITY SOLUTION g z gp E a Specifications m 8 Programming 4 1 2 Clear WL l l J 3 Set Zone Type v 32 wireless zones and 2 wired zones 1 Device m 1 Zone 4 Zone Siren Set a E l l l 5 Chime Zone Set v Periodic supervision for wireless PIR and magnetic switch 6 WL Superv 7 Max Alarm Times v App available in Google play and Apple store control v Window r n remin 2 Keyfobs 1 Keyfob Register dow door open re d 2 Clear Keyfob v User account zone naming 5 Siren 1 WL Siren Reg v PSTN GSM SMS alarm selectable 2 Del WL Siren g VA o Aci vata kute Built in front and rear tampers for control panel ew v 255 event logs with time indication gt 4 CMS 1 v Built in siren 85dB compatible with wired external siren and 3 wireless sirens 4 2 CMS 2 2 Comm m 1 Comm Account 3 SMS Center 1 1PGM and AUX power output SMS Center 2 v 2 central stations working selectable 5 Panel ID 2 Comm Option gt 1 Line Monitor v 6 phone numbers 2 for CMS and 4 for private phones or mobiles 2 Test Interval 3 First Test v 8 codes 1 for installer 1 for master 1 for temporary 1 for duress and 4 for users 4 Call Attem
13. Profile Enter the Profile Name any character name can be input this name will appear in the panel list Enter the alarm phone number must be SIM number in the control panel Enter the User code can be master or user or temporary code 4 Set the function of Q Function can select as below a13 trouble Times can be set from 2 hours to 99 hours Add function to button 1 24 hours is the factory default The period supervision function is closed of all the zones as the factory default Max Alarm Times npon Users can set one zone with max continuous alarm attempts default will be 3 After disarm the device A will restart counting SAVE SETTINGS Keyfob Register Click SAVE SETTINGS Click SAVE SETTINGS to finish setting pane ge Wireless Zones Pie reter tonal Clear Keyfob Same as wireless zones pls refer to that 2 Choose profile In control panel list click control panel s name then click Select button to enter the main interface If users need any change please click Edit Wireless Siren Register ee Same as wireless zones pls refer to that Choose Profile Clear Wireless Siren Same as wireless zones pls refer to that Activate Mute Siren It enables the siren built in siren external wired siren or wireless siren to be on or off Siren Cut off M Siren cut off is the period of time the sirens are activated after an alarm has occurred
14. S LED Ayan Porte system to recognize mawmigua devices each nevIce must be registered For example wie Geucs isa m y P 7 an sinareu or aaustable wireless transmitter registration enables the system to identify the source of a received transmission Each ing cut off adjustable beret aca eo i 2 l device has an individual encrypted ID code Registering the device to the system familiarizes the system with Gas zone Yes Yes Yes ON Ring cut off adjustable this code Panic zone Yes Yes Yes ON Ring cut off adjustable Perimeter zone Yes Yes Yes ON Ring cut off adjustable WL Register Active zone Yes Yes Yes ON Ring cut off adjustable There are two ways of register by code learn or input Entry Exit zone Yes Yes Yes ON Ring cut off adjustable To register by code learn AA Ves vee Ves J Not ring 1 neicer ie zone nuMperending ar If registered Delores ri will raming users to fe Tegisteh ETES H to continue or to quit If not registered before the voice will remind Start enrolling transmit now Tamper zone Yes Yes Yes ON Ring cut off adjustable l with counting down for 60s Line loss No No Yes nen 2 Trigger the wireless asap to avoid any interference AC loss Yes No Yes Not ring 3 The system will remind to save after receiving the signal Press to save or to re register Low batter Yes No Yes Not rin i ses as During register if the signal is received for registered code it will indicate
15. The default master code is 0808 which is strongly recommended to change after installation User Account Naming Each Code has a user account which can be named within 10 letters Names can be given either when first adding a code or by editing them later When the Enter New Name screen is displayed the numeric keyboard can be used to enter text Simply find the corresponding numeric key with the required character and press repeatedly until the wanted character appears Release the key and the cursor automatically jumps to the next position for users to continue with the next character by the same method The keys have the following functions THR 2 abc 3 def 4 ghi 5 jkl 6 mno 7 pars 8 tuv 9 wxyz Back 0 lt space gt Enter A Once the name is added it can be edited but not deleted If really needed please delete Note by initialization Installer Code The Installer code grants access to the Programming menu To set installer code Same as Master code set A Note The default installer code is 1234 which is strongly recommended to edit after installation Temp Code The temp code is just for temporary use which is only valid for 24 hours It will auto clear and must be reset for next time Or after initialization or re power on it will be cleared To edit delete Temp code 1 From the menu select Code set press select Temp code press 2 If any temp co
16. V V VO Installer Code V vV V Duress Code Temp Code User code 1 User code 2 User code 3 Rl Sy lh Sel Se SS eS a 1 Sa Se Pell User code 4 Remark Enter d amp by master code users can set all codes except installer code Enter g amp by installer code users can only set installer code Code Restore If users forget code it need power off the panel open the panel turn jumper See figure 12 to default mode restart the panel to restore code to factory default setting Then users should turn jumper to another side or the panel will restore code when restarting panel next time default 1 E Figure 12 S72 of 7 Service Zone Description There are 8 types of zones entry exit zone active zone perimeter zone panic zone fire zone gas zone tamper zone and duress zone Set Time Date Time and date must be set or else the event log will be recorded with no time arm or disarm may not be There are 38 zones zone 01 16 31 46 is wireless Zone 17 is panic Zone 18 is duress Zone 19 is fire Zone 21 22 is wired Zone 30 is tamper Different zone type alarms in different ways Tamper alarm is valid with 24 hours for wireless zone 1 16 31 46 with tamper alarm indication realized or system trouble will happen voice guide will not work To set time and date 1 Input time and date ending with
17. a panel Fone 15 Alain Sea above Saaabove The control panel will call pre set phone numbers when alarm triggered Users will hear voice alarm after Zone 16 Alarm See above See above pick up and voice alarm will repeat after 5s stop It will totally repeat 5 times The control panel will Zone 17 Alarm See above See above automatically hung up in 5s after the 5th alarm If there is no voice alarm after pick up or you don t want to Zone 18 Alarm See above See above wait you can press 5 on your mobile and the control panel will start playing voice alarm Users can Zone 19 Alarm See above See above operate the control panel during voice alarm stopping time before the panel automatically hung up Zone 21 Alarm See above See above See following Zone 22 Alarm See above See above Disarm press 3 Zone 30 Alarm See above See above Arm away press 3 to disarm and then 1 to arm away Zone 31 Alarm See above See above Arm stay press 3 to disarm and then 2 to arm stay CONA NA Bee ove wee above Repeat alarm press 5 to repeat the alarm Note Alarm is not available to repeat after disarm ee A Turn on siren press 6 Zone 45 Alarm See above See above Turn off siren press 7 Zone 46 Alarm See above See above Press 122 Press 18 2 Barnabae Hang up press 0 to hang up directly and the system will not dial any phone number SMS Operation Users can proceed arm away arm stay disarm status enquiry operation by send
18. ake off the battery before enrolling and then enroll one by one with battery connected A While users register with battery on for all devices there may come wireless signal Note interference and make enroll fail Step 6 Testing the Chosen Mounting Location Once all of the transmitters are registered it is recommended that users test the chosen mounting locations before permanently mounting the control panel and wireless devices Users can test the transmitter signal strength using the TX Test feature Transmitter Test 1 During disarm press with voice guide Enter password before setting parameters Input the installer master code with to enter 2 Select 7 Service gt gt 6 Transmitter gt gt 2 TX text gt Trigger the desired devices and the info about them will display on the LCD 2 gt 4 After all test press to exit 06 Trouble Solutions Keyfob cannot operate the system Battery is drained Replace it with a new battery Enroll Keyfob without programming Enroll Keyfob with programming The system has no feedback when the zone is triggered The zone is bypassed Un bypass the zone When disarm zone 1 2 3 do not alarm arm stay zone 2 does not alarm Operate normally False alarm for wireless zones Different wireless zones use the same code Delete this wireless zone change the code learn a
19. alarm press Ca on keypad the voice will guide Enter password Users can enter arm stay status with code input or direct keyfob operation If under zone alarm press a on keypad or keyfob the voice will guide Disarm before arm If under arm stay press a on keypad or keyfob the voice will guide Arm stay 09 3 Disarm Press C on keypad or keyfob the voice will guide Enter password add 0 to delete the event log Disarm with alarm list cleared Input the code except installer code ending with 0 and the arm LED turns from Red to Green with the voice guide Disarmed alarm log eliminated Disarm with alarm list saved Input the code except installer code ending with just the arm LED turns from Red to Green with voice guide Disarmed Note If disarm by keyfob the alarm list will be saved 4 Window Door open remind When magnetic contacts are registered with control panel if the panel don t collect the close signal from them and it will cause failure when arm away arm stay the system This failure will be indicated with voice Window or door is open Arm failed and SMS message as long as it is selected PGM Trigger Activated by Disactivated 10 S for Line Trb Telephone line supervision trouble Cut off after 10 S Arm away Instant Activate Any arm status change Arm Stay Ins
20. d A Time and date must be set or else the auto arm or disarm function will be recorded with Table 3 Zone Number Note no time With no time set auto arm diarm function may be not available Zone Number Bypass or not Type Remark 1 16 31 46 Applicable Applicable wireless i ial Call Back When Arm Disarm ue mppicenls ae salad With this function the siren will beep when users arm or disarm to remind operation success 18 N A N A duress 1 Press to select ON or OFF press 19 N A N A fire 2 Press to quit when finished Applicable Applicable i aa a eunee i ane anes A Using keyfob to operate the control panel When arm away the built in siren and wired 30 Applicable N A panel tamper Note siren will ring 3 times when arm stay 2 times when disarm one sound Chime Zone It enables the panel with alarm with entry delay during arm or issue Ding Dong under disarm A Note The chime zone function only works for entry exit zone 18 Siren Test Siren test is strongly recommended periodic for safety which includes wired siren wireless siren and built in siren Select the type of siren ending with to test After test press to continue another test Or x to finish 293 When users disarm the system with the duress code the panel doesn t call the first and A second telephone number And the panel just call the third and fourth
21. d according to specific system status conditions The Output Trigger option determines the conditions that activate and deactivate the PGM output To trigger PGM output 1 Select PGM press 2 Press the navigation key to select one of Output trigger and press to exit Tele control via phone Users can remote control the control panel via telephone such as arm away arm stay disarm repeat alarm voice and turn on off site siren etc Users can call the phone number set in the control panel After ring attempts set it will pick up with voice guide to input password ending with For arm away press 1 For arm stay press 2 For disarm press 3 For alarm repeat press 5 turn on siren press 6 turn off siren press 7 Hang up press 0 PGM only compatible with low voltage control board It Shall not be connected with city Note POWE TANSEL Pressing any key on control panel or phone during voice play may cause communication error It A is suggest to operate after voice If the system is under programming remote controlling is not B0 11 See following table Note S l available There should be no voice indication during remote controlling PGM Trigger Activated by Disactivated Not used Null for PGM EAr Zone 1 Alarm Instant Trigger Disarm or PGM cut off Zone 2 Alarm See above See above Dial to alarm vi
22. de is set before it will display with press to edit If not the icon flashes on LCD 3 Input the new code Press to confirm With no code input press to delete it 4 The LCD will remind if it is edited or not Press any key to exit 5 The LCD will remind if need change the name Press to confirm Or to quit 290 Duress Code While users disarm with duress code it will indicate Disarm on site but will send alarm info To set duress code Same as Master code set A Note The default duress code is 0809 which is strongly recommended to edit after installation User Code 1 4 The user code enables users to arm or disarm To set delete user code Same as Temp Code Set os 4 Zone Bypass When a zone is bypassed it is ignored by the system and does not generate an alarm when triggered It enables users bypass one zone or more zones or all zones To bypass one by one 1 Select Bypass one by one press 2 Press to select the zone number ending with 3 And then select ON or OFF ending with 4 Press to quit To bypass all 1 Select BypassAll press 2 It will remind Bypass All press to confirm or press to give up o 5 Phone Set Phone can be personal phone for voice or for SMS The system will dial the phone or send SMS wh
23. en alarm occurs Voice phone set It enables users to edit or delete the number users set before To set voice phone 1 Select one telephone group number press to set 2 If any phone is set before it will display Press to edit If no phone is set before input directly 3 The phone number can be 16 digits utmost Press to finish Or if no figure is input and is pressed directly the number will be deleted Sale
24. ence It will not dial again if it exceeds the attempts Attempts range can be set 1 30 times 7 is the factory default Ring Attempts The Ring attempts means the ring times before the phone hangs up If itis set as 0 it means no remote control by call for the system It can be set from 1 to 9 6 is the factory default GSM Option It includes SMS Ack SMS Confirm and SMS Send If SMS Ack is turned off then it is not available for control panel If SMS confirm is turned off then SMS receipt is not available If SMS Send is turned off then SMS Send is not available Onas default CMS cooperate With this function available if the alarm info is sended to one CMS then it will not dial or send message to another CMS While with this function closed then the alarm will be sended to both CMS Onas default Programming System Option Entry Delay Entry delay means a period for user to enter detection area activate the delay zone and disarm before the system alarms Times can be set from 0 seconds no delay up to 300 seconds in 1 second increments 100 seconds is the factory default 290 CMS event Option The options are send for alarm send for arm amp disarm send for system trouble send for service info If the function of Send for Alarm is closed the alarm info will not be sent to CMS If the function of Send for Arm Disarm is closed the arm or disarm operation will not be s
25. ent to CMS and cancel alarm is invalid If the function of Send for Trb is closed the trouble info will not be sent If the function of Send for service is closed the trouble info will not be sent during enter or quit programming or zone bypass It will send all events as default SMS 1 2 Center Number SMS center uploads event log through GSM network which includes alarms arm amp disarm system trouble event log and service info The phone number can be edited or deleted To set SMS center number 1 Select Comm Account ending with 2 Press the navigation key to select SMS center 1 or 2 ending with 3 If any number is set before it will display on the LCD Press the icon will flash for figure input While no number is set users can input directly with icon indication 4 The phone number is 16 digits utmost ending with Press to delete former digit or edit it Press to confirm If press directly the former phone number will be deleted SMS Event Option SMS center event option includes send for alarm send for arm amp disarm send for system trouble send for service info If Send for Alarm is closed The alarm info will not be sent to SMS if the function of Send for Arm Disarm is closed The arm or disarm operation will not be sent If the function of Send for Trb is closed the trouble info will not be sent If the function of
26. es Activating periodic supervision for accessories it ensures system safety 01 CONTENTS a 1 Easy Ung tall ncnccteceecceeesse ened eacteedeceeseec cient deena cteee dean ade aa 3 USACE ee eee eee ae g 3 Using Systeme Mote Details lt seeceeeeesenstesece acest stece esate aina 15 A Menu Systeim in Detail s lt ecenece neta ence cee reeet asec neaemtecennectn en cepa enaectuereee 19 5 Troubleshooting eee ee Ee aiea 34 Pare tes eect cere aca eee 36 7 ADP ndix C 37 02 Term Definitions Detector A facility that detects intrusion and abnormal state automatically via some electric or physical methods and output switch signals or wireless signals to the system for disposal then output alarm signals such as infrared detector smoke detector etc Zone An area of the detection range of one or group of detectors Bypass Close one of the zones temporarily so that it cannot alarm while act in the zone Arm Away The armed status while going out All the zones without bypass are in armed status Arm Stay Alarm status while you are at home All the zones are in armed status except active zones Disarm Close the entry exit zones active zones perimeter zones Other zones are still in arm status 24 hour zone No matter armed or disarmed it is in valid detecting status It is usually used in fire alarm duress alarm and other emergent alarm which can be canceled only by password holder CMS Itis an alarm receiving stat
27. est press The voice will guide Transmitter test starts transmit wireless signal 2 Trigger the transmitter if it is registered the info will display on LCD If it isn t registered it will indicate as unknown signal 3 Press to quit after test finish GSM Test To ensure the validity of GSM communication please test the signal network at the installing position To test GSM signal From the menu select Service gt gt GSM test gt 7 GSM Test No SIM Back Enter 24 Keypad Lock and Unlock If the code is input wrong the voice will guide Wrong password please re input And if the code is input wrong for 5 times the voice will indicate Access locked please try later After the code is locked and operate any step which requires code the voice will guide Access locked please try later If the code is locked when there is no alarm but alarm occurs after the code lock the system will auto release the code lock While if the code is locked after alarm auto release must be available after system re initialization or within 30 minutes Codes Access There are 5 types of codes master code installer code duress code temporary code and user code 4 Different authorizations are appointed for different codes Code Type Arm amp disarm Enter Menu Code Set Programming in menu Editable Clearable Master Code
28. etic Contact 2 Bypass All _ 2 Unbypass All SS 1 Set Date dd mm yy M 01 01 2000 7 of 5 Phone Set a Page 21 1 Voice Phone Set 1 Voice Phone 1 2 Set Time 24 hour 2 Voice Phone 2 00 00 Y 3 Voice Phone 3 4 Voice Phone 4 N Refer to page 05 Refer to page 19 23 Open the battery case and put the pater in g P 2 SMS Phone Set 1 SMS Phone 1 2 SMS Phone 2 6 WL Zone Register WA Keyfob Register ST Transmitter Testing z SM3 Enone 3 WL Zone 1 Keyfob 1 TX Testing aN s 6 Eveni Page 22 Eas gJs os vent Log Page 22 o A panes x 1 Auto Time 1 Refer to Page 25 Refer to page 26 Refer to page 24 7 7 Service tale Auto Avmn Dis Time 2 Auto Time 2 3 Call Back When Arm Dis s Auto un G GSM Signal Testing J Panel Installation Va Devices Installation 4 Siren Test Auto Vv 5 Walk Test 1 Wired Test 7 GSM Test in 2 WL Test Signal Strength 0 31 3 Built in Test 18 o 6 Transmitter ___ 1 Transmitter List 2 Transmitter Test Refer to page 24 Refer to page 07 08 Please refer to relative manuals 7 GSM Test 8 Audio 1 Volume J Walk Testing vA Phone Set VA Alarm Testing Disarm 7 9 Send Test SMS Interval Walk Testing Fae s 5 Phone Set 1 WL Zone 1 1 Voice Phone Set Zone 01 Fire Untreated 10 Version ANE ERTE 2 SMS Phone Set Zone 02 Fire Untreated f Wo EE ET s 8 Programming a Page 25 Refer to page 24
29. ing SMS to control panel Please check below two ways of operation Method 1 Edit SMS manually then send to control panel XxXxx is user password Users send SMS passwordxxxxarmaway to control panel can realize arm away send SMS passwordxxxxarmstay to control panel can realize arm stay send SMS passowrdxxxxdisarm to control panel can realize disarm For example suppose user password is 0808 and control panel ID is 1234 then the exact operation is as follow gt Arm away SMS password0808armaway ID 1234 ID 1234 Prog Arm away Prog Arm away Act 0K Act ERR Operation succeeded or failed reply gt Arm stay SMS password0808armstay ID 1234 ID 1234 Prog Arm stay Prog Arm stay Act 0K Act ERR Operation succeeded or failed reply gt Disarm SMS password0808disarm ID 1234 ID 1234 Prog Disarm Prog Disarm Act 0K Act ERR Operation succeeded or failed reply Test Interval The Periodic Test is a test transmission the system sends to notify the central station that its reporting capability is fully functional And the test periodic test interval can be adjusted First Test First test interval means the time for first periodic test to start Call Attempts The Call attempts option determines the number of times the system tries to call a telephone number before moving on to the next number in sequ
30. installer code to enter main menu Press the to select what users desire to set and confirm with or Press to exit A Note Programming option is only available with installer code Quit Programming if Press to quit programming to previous menu Or it will return to previous automatically with no operation within 1 minute _ Available with installer code o Available with master code Programming Items o 1 Cancel Alarm With misoperation or unexpected alarm occurs users can Cancel Alarm in the menu Thus the panel will issue an event cancel to CMS oy 2 Stop Comm Through this operation all communication buffers are cleared and all pending messages are canceled o 3 Code Set Code is available as 4 6 digits If the code is set 5 or 6 digits the last one cannot be 0 The code must be different Master Code The Master code is the highest user authorization level It enables users to enter main menu which can be edited With the Master code users can edit all other user codes except the installer code To set master code 1 From the menu select Code set press select Master code press 2 Press to edit Input the new master code ending with 3 The LCD will remind if itis edited or not Press to confirm Or to quit 19 A Note
31. io transmissions Having chosen and tested the mounting location of the control panel and each transmitter it is ready to permanently install the panel At first stick Installing Hole Drawing on the location for control panel Drive 4 screws on the fixed position see Figure 6 and then hang the control panel directly on the screws see Figure 7 While driving the screws pls pay strict attention to the depth of screws to make sure easy hang and tamper switch work normally There are 2 tamper switches front tamper and rear tamper Compress the tamper switch while installing If the control panel is removed or opened tamper will be triggered 07 Programming Initialization Initialize All The Initialization function clears programming of the whole system and restore factory defaults Installing Hole Drawing Load Defaults This function enables users to restore the factory set programming defaults which keeps the control panel ID and will not delete the set phone numbers or wireless devices Clear Users Clear User Codes deletes all programmed user codes and restores the default master and installer codes and duress codes VVVVVAVVAVAVAVVAVAVAAAAANY Wall Figure 6 Figure 7 Clear Users by Hardware A While hanging the control panel please don t shake the product to avoid breaking the tamper switch Clear user codes can be also realized by hardware jumper There is a jumper on the contro
32. ion to which the alarm controller sends out alarm information via telephone line when alarm occurs The station will take corresponding actions after receiving the alarm Entry Delay A period for user to enter detection area activate the delay zone and disarm before the system alarms During the period user can activate several specified zones entry zone wihout alarm immediately While exceeding the time the system alarms if not disarmed Zones with entry delay are the exit entry zone and active zone Exit Delay A period for user to leave detecting area once the system armed Zones with exit delay will not alarm during this period The zones with exit delay are the exit entry zone and the active zone Supplementary Entry Delay The Supplementary Entry Delay is a pre alarm feature that is employed in the event that the system is not disarmed during the entry delay Panel ID ID can be set for each control panel so that the CMS can identify Different ID must be set for different control panels which is 4 8 digits utmost with default as 1234 Duress Code When user is forced to disarm the control panel by burglar user inputs duress password the control panel is disarmed but sends alarm information to the center stations or receiver The duress password can be used to disarm but set parameters Chime Zone During disarm while the zone is triggered the panel will sound Ding Dong 230 2 Easy Install Table 5 Contact ID Event
33. isarmed after alarm 2 Press the navigation key to select the zone users desire to set ending with and then select the zone type for it ending with to save it 3 Press to exit Alarm Display Zone Siren Set The alarm will display with voice guide in the Alarm List Press to select with to query the It enables the user to active or mute external siren for some zone ON enables the siren to buzzer event Press to quit during alarm while OFF enables the siren dummy This function is available for Zones No 1 16 31 A6 wireless zones 21 22 wired zones No 17 and 19 00 Alarm Uist Alar aa Unto Zone 17 Gas Untreated Zone 01 kitchen Chime Zone Set Type ie It is only available for entry exit zones to enable the Chime zone Function During disarm trigger the ine a a zone the voice of Ding Dong will be given off Wireless Zone Supervision Wireless devices will transmit supervision signal to the control panel at intervals If the system does not receive any signal then the transmitter is regarded as loss The max loss period is called supervision 26 15 Alarm Type and Way A Signal strength 0 31 31means the strongest To make sure the normal communication please There are two alarm type instant alarm and delay alarm Note confirm itis over 12 Trigger 24 hour zones instant alarm will occur 24 hour zones include
34. l Transmitters Load Defaults Reset as Default AG Introduction i po General System Overview Thank you for choosing our wireless alarm kit which offers an innovative all in one solution with all aspects of security and connectivity covering a full range of wireless accessories Window Door Open Remind The Control Panel can recognize and record the door contact condition Users can set as forbid arm or allow arm but with remind system problem Also can choose to close the Window Door Open Remind User Account Zone Naming Each Wireless Zone Code can be given a 10 character name Names can be given either when first adding a Zone Code or by editing them later All names can be deleted only in Initialization All The name will be show in event log or SMS APP Control After install the App4Home software users can use smart phone to control some function of panel like Arm disarm bypass turn on turn off siren etc each processing in Alarm4Home mobile phone will send one charge SMS to control panel Number Of Devices Users can install up to 32 wireless detectors in the system As well as extra door window contacts PIRs and smoke detectors users can add up to 2 wire detectors 6 keyfobs 3 wireless sirens 1 wire siren and 1 PGM PSTN GSM I SMS Featuring PSTN GSM dialing or SMS send optional it offers multiple performance options and the flexibility Supervision For Accessori
35. l panel board J3 See Figure 17 If user codes are forgotten pls power off and put the jumper to Default and then restart the system which will reset user codes as default A Then user should turn jumper to another side or the panel will restore password when 2 Using System a Note restarting panel next time Arm and disarm the system and practice using it Trigger the alarm by arming the system and opening Reset Zone Type protected door windows and walking past PIRs This function resets all wireless zones into panic and all wired zones into entry exit zones Signal LED m Front Panel Keypad See Page 9 Alarm LED p Clear Wireless Clear all wireless devices includes wireless sensors keyfobs and sirens cf Disarm Power LED aH 1 Arm away Dr Arm stay Arm LED 4 Panic OOOO EnD LOOO Figure 8 0000000000009 X Figure 9 08 33 To set AC loss delay 1 Select AC loss delay M press 2 Input the delay time 001 255minutes or 000 for system random setting 3 Press to finish Line Loss Delay It allows amount of time that Line Loss is not reported to center station while the telephone line is disconnected While before the message is sent to the station and the telephone line recovers connected well the mes
36. nd try again Abnormal work for PSTN board using ADSL Connectthe phone interface of PSTN board to phone interface of ADSL segregator If the problem still cannot be realized please change a high quality segregator During walk test re trigger for detector cannot be realized after 1st trigger There is a sleep period of 5minutes for detector to save battery between 2 triggers Wait 5 minutes after the 1st trigger LCD display is abnormal or dirty Pin connector for LCD is not stable Re connect the pin connector for LCD User code restore to default code after system repowered Jumper setting is not correct Refer to Page 17 Code Restore 35 5 Troubleshooting ai fo System Trb will display on LCD if there is Users can press to enter the trouble list and then press or to check If the trouble is solved it will disappear out of the list Users can clean the display of system trouble remind except zone 21 22 trouble by disarm the system but system trouble information will still be saved in the system trouble list If the time is unset the voice guide of trouble will not sound System trouble voice indication will not be Walk Test 1 Enter Menu 2 Select 7 Service gt 5 Walk Test 3 Trigger the desired devices and the info about them will disappear on the LCD 4 After all test press to exit
37. or and plug in backup battery 05 Parameters of power adaptor Input 100V 240VAC 50 60HZ 0 5A Output 12VDC 1 5A Backup battery 7 2V 1800mAh Nim H and rechargeable 24 hours is required for full recharge which can last around 8 hours for this system under standby situation After low battery warning it can work for around 30 minutes The system will keep the time and date with time chip powered If the power of time chip runs out users need to re set the time manually The icon will move to next automatically after each input Press to exit After complete input press to confirm If the input is not finished and meanwhile is pressed it will display on the LCD Invalid Set Pls press to re input it There will not alarm when anti tamper was trigged only flashing remind In three hours power on A AC power must be connected for initialization Or else it can not be initialized with just Note backup battery Step 5 Register Transmitters Transmitters refer to wireless devices such as detector magnetic contact siren and keyfob etc Only after enrolling can transmitters be recognized by the control panel To register a device 1 During disarm press With voice guide Enter password before setting parameters Input the installer code with 2 For specific register process pls refer to WL keyfob register and WL Siren Reg See Page 25 26 Please t
38. porary code by keypad phone or SMS 05 08 Arm disarm using user code 1 4 by keypad phone or SMS 11 16 Arm disarm by keyfob 1 6 21 24 Arm disarm by phone number 1 4 during alarm 30 Auto arm disarm 99 Bypass all or unbypass all 38 03 Step 3 Connect external devices Device Under Control oo e PGM GND External Power Telephone LINE_OUT LINE_IN Telephone Line Figure 3 Wired Siren Connection The max drive of BELL terminal is 400mA 12VDC Connect the bell power line to BELL and GND Users can try to program via keypad to set if the siren beeps and how long it beeps Note The wired siren is invalid with only backup battery AUX Power Output Terminal AUX supplies power output for wired detectors AC Operated 10 12V Battery Operated 6 8V max current 100mA It may cause abnormal working for wired detector under low battery Home Appliance Control PGM Connection The max load of PGM output is DC25V 500mA Boolean value is output with PGM on connected with GND of PCB board 04 7 Appendix Warranty and Limitations Although it is an advanced and reliable security system it does not offer absolute guaranteed protection against burglary fire or other troubles The limitations are as follows 1 Intruders may get access to unprotected openings or have technical sophistication to invalidate the system
39. pts 5 Ring Attempts v Support 6 keyfobs 6 GSM Option 7 CMS Coopertion v Contact ID protocol v Wireless frequency 433MHz 868MHz 3 System Option gt 1 Entry Delay S 2 Exit Delay S 3 Supp Ent Delay 4 PGM g 5 Zone Trb Ind Packing List 6 AC Power Off Delay M 7 Line Loss Delay S 8 GSM Function Control Panel x1 9 Window Door Open Remind 10 Arm With Open Doors Keyfob x2 Wireless PIR Detector x1 l Wireless Magnetic contact x1 4 Initialization gt 1 Initialize All Power Adaptor x1 2 Load Defaults 3 Clear Users Installation Manual x1 4 Reset Zone Type 5 Clear WL Accessories screws 4 pcs EOL resistance 2 2K 4pcs and installation screws 4pcs xy Available with installer code o Available with master code AO x Available with installer code QUICK GUIDE o 1 CancelAlarm _ Page 19 i of 1 Master Code Eaa aa eda J Insert SIM card A Connect Backup Battery ee ee A 3 a of 3 Code Set a Page 19 of 4 Temp Code LOCK gt gt of 5 User Code 1 oa P of 6 User Code 2 f of 7 User Code 3 of 8 User Code 4 Press to open the case refer to page 03 Refer to page 05 of 4 Zone Bypass Page 21 1 Bypass One By One 1 Bypass All F Power On Control Panel Z Enter Menu and Set Time Power On Detector Magn
40. s 2 Press to edit with icon indication 3 Enter a PGM cut off time 0 300s 000 means continuous activation until disarm 4 Press to exit when the desired setting is displayed Zone Trouble Indication This option enables users to select whether zone trouble will be indicated in the system trouble list If this function is turned off it will not display AC Power Off Delay The AC Loss Delay is the amount of time that allows AC loss report been hold If AC power recovered during this time the event message will be canceled and not reported The AC Loss Delay can be set alternatively between 1 and 255 Min Correspondingly AC Restore is reported only if the AC Loss report was sent AC loss delay is mainly used when the power is not stable 31 Exit Delay Trigger fire alarm A period for user to leave detecting area once the system armed Zones with exit delay will not alarm during this period Times can be set from 0 seconds no delay up to 300 seconds in 1 second increments Press on keypad for 2s 100 seconds is the factory default Supplementary Entry Delay The Supplementary Entry Delay is a pre alarm feature that is employed in the event that the system is not disarmed during the entry delay And the period is set as 5s While this function is turned off the system will alarm immediately after entry delay Figure 11 PGM The PGM is a programmable output that is triggere
41. s no balance for SIM card Dialling Trouble 1 Refuse or power off of receiving phone Pick up the phone in time 2 Overdue of the SIM card Check if there is no balance for SIM card No call for alarm Set correct voice telephone number Set more than two voice telephone numbers Telephone can not work normally as the system is connected into telephone network Few ringing attempts lead the system to hang up the phone automatically Increase ringing attempts Refer to ringing attempts adjustment 34 Test GSM signal The communication signal strength should be tested to confirm if GSM module work well To test GSM signal 1 Enter Menu 2 Select 7 Service gt gt 7 GSM Test gt 0 31 means for the signal strength 31 means the strongest To make sure normal communication pls use over 12 Step 7 Permanently Installing In order to optimize wireless communication consider the following guidelines 1 Whenever possible mount the panel centrally in relation to wireless sensors 2 Avoid installation in close proximity to sources of high noise or radio frequency interference For example air conditioner heater or circuit breaker boxes 3 Minimize the distance between the panel and transmitters 4 Minimize the number of obstacles between the panel and transmitters 5 Metal based construction materials such as steel reinforced concrete walls will reduce the range of rad
42. sage will be canceled Or if the message for Line loss is sent to the station successfully before the connection recovered the line recover message will be also sent To set line loss delay 1 Select Line loss delay S press 2 Input the delay time 001 255s or 000 for system random setting 3 Press to finish GSM Function This option enables users to select whether system support GSM module If GSM Function is turned off it will not display GSM module trouble and work To set GSM Function 1 Select GSM Function then press 2 Press the to select ON or OFF and confirm with 3 Press to exit Window Door open remind This option enables users to turn ON OFF the function of window door open remind The panel will detect the situation of Magnet and remind users Door or Window is Open when users arm the system If Zone malfunction is allowed to display the system will remind and display system trouble It will disappear after users close the window Arm with open Window Doors User is allowed to set if the system can be armed while window door is open If setting is ON Arm with open doors is allowed Otherwise it will be prohibited A Note This function only works with Window Door open remind is ON 89 Front Panel Keypad For arm away For arm stay For disarm and also for fire alarm pre
43. ss for 2s For programming and also for panic alarm press for 2s Figure or navigation key for upturn for menu operation or query Figure or navigation key for down turn for menu operation or query It means delete while inputting figures or quit for menu operation For enter SOS COG Cle Arm Disarm via keypad or keyfob Users can arm away arm stay disarm or emergence via keypad or keyfob If CMS is connected with message send and info except zone alarm is set to send any operation like arm and disarm will be reported to CMS Arm or disarm is not available during programming or trouble query Via keypad requires master user code while via keyfob requires no code 1 Arm Away When the system is under disarm press on keypad or keyfob the status LED turns from Green into Red with the voice guide Arm away close door and window exit delay with the music When the exit delay ends the voice guide will sound Armed away If during zone alarm press on keypad or keyfob the voice will guide Disarm before arm If under arm situation press on keypad or keyfob the voice will guide Armed away 2 Arm Stay It enables users not to alarm in active zone but alarm in other zones If under disarm press on keypad or keyfob the status LED turns from Green into Red the voice will guide Arm stay If under arm away and with no
44. tant Activate Any arm status change Disarm Instant Activate Any arm status change Siren follow Siren follower Siren follower Entry Exit Activate Until disarm or after PGM cut off Active See above See above Perimeter See above See above Panic See above See above Fire See above See above Gas See above See above Tamper See above See above Duress See above See above a The interfering will cause the signal failure of wireless signal then Arm failure At that situation please separate and close the magnetic contacts again to make sure Arm successful For A security reasons itis strongly suggested to make sure every arm successful This can be Note audio confirmed by internal siren sound and SMS massage To set the internal siren refer to page 23 Call Back When Arm Disarm b If users want to ignore the open area remind please refer to page 32 to turn off this function Trigger alarm via keypad It enables users to trigger alarm via keypad or keyfob in emergency Trigger panic alarm Press gt on keypad or on keyfob for 2s Figure 10 10 With all conditions satisfied PGM will output The PGM under Go 10s when line loss arm away arm stay disarm or siren follow is not determined by PGM cut off time while PGM under other situations will switch to disactivated after PGM cut off The PGM cut off can be set by programming To set PGM cut off 1 Select PGM Cut off pres
45. telephone number So Note wesuggestthatdon t set the third and the fourth telephone number with personal phone number Voice Phone Interface Set It enables users to select PSTN or GSM as dialling way To set voice phone interface 1 Select the telephone group number press to enter 2 Press to select the communication interface PSTN or GSM ending with 3 Press to quit A When the telephone line loses it will transfer into GSM dialling automatically SMS Phone Same as voice phone set SMS Option users can select if SMS message will be sent or not for alarm arm or disarm to save SMS cost To set SMS option 1 Select the phone group number press to enter 2 Select parameters users desire to set ending with 3 Select ON or OFF o 6 Event Log This system can save 255 event logs including alarm and operation issues When it exceeds 255 it will substitute the earliest event To query event 1 From the menu select Event log press to enter The earliest event will display 2 Press to query 3 Press to quit when finished 22 4 Menu System in Detail ee Default installer code 1234 Default master code 0808 Enter Programming To configure the system or make any changes to the pre set functions During disarm press d amp on keypad Input master code or