Home
EUROLITE LED Ribbon H & V User Manual - LTT
Contents
1. 5 and 35 Celsius Use is permitted with pure clear water only Distilled water is recommended DESCRIPTION OF THE DEVICE Features Fountain with jug in clay look e Made of high quality and glass fibre reinforced plastic e Enhances air humidity in rooms and thus the well being Pump included in delivery INSTALLATION Install the fountain basin at the desired location Connect the pump with the pump hose Fix the pump with the suction feet to the ground of the fountain s interior Attach the upper part of the fountain on the fountain basin and lock it by turning bayonet cap Fill the device with water distilled water is recommended With conventional tap water sediment can gather on the pump after some time which will destroy it The water flow can be adjusted at some fountain models with the control valve on the pump enclosure This fountain is designed for standing installation only The device may only be installed absolutely planar at a vibration free oscillation free location Connect the transformer to the mains 9 10 00053231 DOC Version 1 1 CLEANING AND MAINTENANCE DANGER TO LIFE Disconnect from mains before starting maintenance operation We recommend a frequent cleaning of the device Please use a soft lint free and moistened cloth Never use alcohol or solvents If the fountain is to be shut off for a longer period of time please remove the water completely Otherwise it may lead to algal an
2. muss zwischen 5 und 35 Celsius liegen Eine Verwendung ist nur mit reinem klarem Wasser erlaubt Destilliertes Wasser wird empfohlen GER TEBESCHREIBUNG Features Brunnen mit Krug in Tonoptik e Aus hochwertigem und glasfaserverst rktem Kunststoff Steigert die Luftfeuchtigkeit in R umen und dadurch das Wohlbefinden e Pumpe im Lieferumfang enthalten 5 10 00053231 DOC Version 1 1 Deutsch MONTAGE Stellen Sie die Brunnenschale am gewunschten Ort auf Verbinden Sie die Tauchpumpe mit dem Pumpenschlauch Fixieren Sie die Pumpe mit den Saugnapfen auf dem Boden im Inneren des Brunnens Setzen Sie das Brunnenoberteil auf die Brunnenschale und verriegeln Sie es durch Verdrehen Bajonettverschluss Bef llen Sie den Brunnen mit Wasser destilliertes Wasser wird empfohlen Bei herk mmlichem Leitungswasser k nnen sich nach einiger Zeit Ablagerungen an der Pumpe festsetzen die diese zerst ren Die F rdermenge der Pumpe kann bei manchen Brunnenmodellen ber einen Drehschieber am Pumpengeh use ver ndert werden Der Brunnen ist nur zur stehenden Montage vorgesehen Der Installationsort muss so gew hlt werden dass der Brunnen absolut plan an einem festen ersch tterungsfreien schwingungsarmen Ort aufgestellt werden kann Stecken Sie den Netzstecker in eine Steckdose ein REINIGUNG UND WARTUNG LEBENSGEFAHR Vor Wartungsarbeiten unbedingt allpolig vom Netz trennen Das Ger t sollte regelm ig von Verunreinig
3. and elektrischem Schlag etc verbunden Der Brunnen ist gegen u ere mechanische Einwirkungen zu sch tzen Behandeln Sie das Ger t sorgf ltig Vermeiden Sie St e Schl ge Fall oder Druck auf die empfindlichen Oberfl chen des Brunnens Der Brunnen darf nur mit der mitgelieferten Original Pumpe betrieben werden Ziehen Sie vor dem Ber hren oder Entfernen der Pumpe aus dem Wasser immer erst den Netzstecker aus der Steckdose Halten Sie keine K rperteile wie beispielsweise Finger in den Brunnen Setzen Sie keine Lebewesen wie z B Fische in das Wasser des Brunnens Eine Verwendung der Pumpe in Schwimmbecken Bade und Duschwannen ist nicht gestattet Weisen der Brunnen oder die Zuleitung mechanische Sch den auf darf das Ger t nicht mehr betrieben werden Achten Sie darauf dass im Umkreis des Brunnens keine wasserempfindlichen Gegenst nde stehen und auch der Untergrund geeignet ist da vereinzelt Wasserspritzer austreten k nnen Dies gilt im Besonderen f r Steckdosen und bewegliche Steckdosen wie beispielsweise Tisch oder Mehrfachsteckdosen Sorgen Sie unbedingt daf r dass keinesfalls Feuchtigkeit oder Spritzwasser eintritt Lebensgefahr Stellen Sie sicher dass die Pumpe immer vollst ndig im Wasser eingetaucht ist Kontrollieren Sie regelm ig den Wasserstand Die Pumpe darf nicht trockenlaufen Ziehen Sie vor dem Nachf llen von Wasser immer erst den Netzstecker aus der Steckdose Die F rdertemperatur des Wassers
4. ch m ssen unbedingt eingehalten werden Die Umgebungstemperatur muss zwischen 25 C und 45 C liegen Halten Sie das Ger t von direkter Sonneneinstrahlung auch beim Transport in geschlossenen W gen und Heizk rpern fern Die maximale relative Luftfeuchte betr gt 100 bei einer Umgebungstemperatur von 25 C Dieses Ger t darf nur in einer H henlage zwischen 20 und 2000 m ber NN betrieben werden Verwenden Sie das Ger t nicht bei Gewitter berspannung k nnte das Ger t zerst ren Das Ger t bei Gewitter allpolig vom Netz trennen Netzstecker ziehen wenn anwendbar Die maximale Umgebungstemperatur T 45 C darf niemals berschritten werden Nehmen Sie das Ger t erst in Betrieb nachdem Sie sich mit seinen Funktionen vertraut gemacht haben Lassen Sie das Ger t nicht von Personen bedienen die sich nicht mit dem Ger t auskennen Wenn Ger te nicht mehr korrekt funktionieren ist das meist das Ergebnis von unfachm nnischer Bedienung 4 10 00053231 DOC Version 1 1 Soll das Ger t transportiert werden verwenden Sie bitte die Originalverpackung um Transportsch den zu vermeiden Beachten Sie bitte dass eigenm chtige Ver nderungen an dem Ger t aus Sicherheitsgr nden verboten sind Wird das Ger t anders verwendet als in dieser Bedienungsanleitung beschrieben kann dies zu Sch den am Produkt f hren und der Garantieanspruch erlischt Au erdem ist jede andere Verwendung mit Gefahren wie z B Kurzschluss Br
5. cherheits hinweise und die Warnvermerke beachten die in dieser Bedienungsanleitung enthalten sind IJ Unbedingt lesen Bei Sch den die durch Nichtbeachtung dieser Bedienungsanleitung verursacht werden erlischt der Garantieanspruch F r daraus resultierende Folgesch den bernimmt der Hersteller keine Haftung Das Netzteil immer als letztes einstecken Halten Sie das Ger t von Hitzequellen wie Heizk rpern oder Heizl ftern fern Das Ger t darf nicht in Betrieb genommen werden nachdem es von einem kalten in einen warmen Raum gebracht wurde Das dabei entstehende Kondenswasser kann unter Umst nden Ihr Ger t zerst ren Lassen Sie das Ger t solange uneingeschaltet bis es Zimmertemperatur erreicht hat 3 10 00053231 DOC Version 1 1 Der Aufbau der Pumpe entspricht Schutzklasse Der Netzstecker darf nur an eine Schutzkontakt Steckdose angeschlossen werden deren Spannung und Frequenz mit dem Typenschild der Pumpe genau bereinstimmt Ungeeignete Spannungen und ungeeignete Steckdosen k nnen zur Zerst rung der Pumpe und zu t dlichen Stromschl gen f hren Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Beachten Sie bitte dass Sch den die durch manuelle Ver nderungen an diesem Ger t verursacht werden nicht unter den Garantieanspruch fallen Kinder Laien und Tiere vom Ger t fern halten Im Ger teinneren befinden sich keine zu wartenden Teile Eventuelle Servicearbeiten sind ausschlie lich dem au
6. d bacterial growth in the course of time Remove all water out of the device To eliminate the residual water which can accumulate in the recesses of the fountain use a water absorbing rag or sponge We generally recommend a periodic cleaning of the fountain and change of water to keep the water quality consistantly fresh There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by authorized dealers Should you need any spare parts please use genuine parts Should you have further questions please contact your dealer TECHNICAL SPECIFICATIONS Power supply 230 V AC 50 Hz Power consumption 8W Dimensions LxWxH approx 410 x 410 x 550 mm Weight approx 5 kg Please note Every information is subject to change without prior notice 08 09 2010 10 10 00053231 DOC Version 1 1
7. erent to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock etc 8 10 00053231 DOC Version 1 1 Protect the fountain against external mechanical influence Take care with the fountain Avoid blows knocks falls or pressure on the sensitive surfaces of the fountain The fountain must only be operated with the original pump Prior to handling the pump or removing it from the water always unplug the power adapter from the socket Do not hold any parts of your body such as your fingers into the water fountain Do not put animals e g fishes into the water Using the pump in swimming pools bathtubs or showers is not permitted Should the fountain or the cable show signs of mechanical damage discontinue using the device Make sure that there are no objects susceptible to water around the fountain and also the ground is suitable as water may sporadically be splashed around This goes in particular for power outlets portable socket outlets such as table or multiple socket outlets Do not allow moisture or splash water to enter Danger of life Please ensure that the pump is fully submerged in the water at all times Check the water level regularly The pump shall not run dry Always unplug the power adapter from the socket before refilling water The conveyance temperature of the water must lie between
8. ly The arising condensation water might damage your device Leave the device switched off until it has reached room temperature 7 10 00053231 DOC Version 1 1 The pump falls under protection class The power plug must only be plugged into a protection class outlet The voltage and frequency must exactly be the same as stated on the pump Wrong voltages or power outlets can lead to the destruction of the pump and to mortal electrical shock Always disconnect from the mains when the device is not in use or before cleaning it Please note that damages caused by manual modifications on the device or unauthorized operation by unqualified persons are not subject to warranty Keep away children amateurs and pets from the device There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by authorized dealers Caution Only the pump s and the connection cable power cable may come in contact with water not the plug in adapter Be sure to allow a drip loop i e at least at one point the power cable should hang lower than the pump and the power outlet At this point water may be able to drip down instead of reaching the power outlet Please keep in mind that the power cable may pose a trip hazard OPERATING DETERMINATIONS This device is a fountain for decorative purposes and was designed for indoor and outdoor use The pump is only allowed to be operated with an alternating curre
9. manual is valid for the article numbers 83309177 Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under www europalms de 2 10 00053231 DOC Version 1 1 Deutsch BEDIENUNGSANLEITUNG ohne Brunnen Alle Personen die mit der Aufstellung Inbetriebnahme Bedienung Wartung und Instandhaltung dieses Ger tes zu tun haben m ssen entsprechend qualifiziert sein diese Bedienungsanleitung genau beachten die Bedienungsanleitung als Teil des Produkts betrachten die Bedienungsanleitung w hrend der Lebensdauer des Produkts behalten die Bedienungsanleitung an jeden nachfolgenden Besitzer oder Benutzer des Produkts weitergeben sich die letzte Version der Anleitung im Internet herunter laden EINF HRUNG Wir freuen uns dass Sie sich f r diesen Brunnen entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie den Brunnen aus der Verpackung SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gef hrlicher Netzspannung Bei die ser Spannung k nnen Sie einen lebensgef hrlichen elektrischen Schlag erhalten Dieses Ger t hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen muss der Anwender unbedingt die Si
10. nt of 230 V 50 Hz This device is waterproof IP X8 and therefore qualified for indoor and outdoor use In order to maintain this protection grade after opening the housing any rubber sealings must be examined for damages and always be correctly installed For outdoor use the installer must always make sure to connect a rubber cable HOSRN F or HO5RR F For installations in the ground an underground power cable NYY must be used All valid instructions concerning the installation of cables outdoors or in the ground must be adhered The ambient temperature must always be between 25 C and 45 C Keep away from direct insulation particularly in cars and heaters The maximum relative humidity is 100 with an ambient temperature of 25 C This device must only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms The maximum ambient temperature T 45 C must never be exceeded Operate the device only after having become familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation Please use the original packaging if the device is to be transported Please consider that unauthorized modifications on the device are forbidden due to safety reasons If this device will be operated in any way diff
11. r manual carefully before you initially start up Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the product pass this manual on to every further owner or user of the product download the latest version of the user manual from the Internet INTRODUCTION Thank you for having chosen a fountain If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Unpack your fountain SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual US Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems Always plug in the power unit last Keep away from heaters and other heating sources If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediate
12. rasche BEDIENUNGSANLEITUNG USER MANUAL Fountain F r weiteren Gebrauch aufbewahren Copyright Keep this manual for future needs Nachdruck verboten Reproduction prohibited MULTI LANGUAGE INSTRUCTIONS Inhaltsverzeichnis Table of contents EINFUHR UN Geer 3 SICHERHEITSHINWEISE Ea a ANA ana AA Yna aan 3 BESTIMMUNGSGEM SSE VERWENDUNG annann nennen 4 GERATEBESCHREIBUNG ccsccecccesscescececceenccencececesacecenecscesecesscesseceseeensceensenceensecaeesaneseeeesacsesseceneeseeenseees 5 Feat reS eae re ee ee EE 5 del TAG EE 6 REINIGUNG UND WARTUNG 2uuuuu 20220n2000000nan000nannnnnnnnnnnnnnnnnnunnnnnnnnnnannnnnn nn nnnnn ann nun ann nun nn nnnnnnnnnnnnnnannnnnnnn nun 6 TECHNISCHE DATEN 2 23 2255 4424 4450420 08520802400 ene Ee dee ee e Sege dee NIAN AALANGAN 6 INTRODUCTION WE 7 SAFETY INSTRUCTIONS uu222000000000000000000nnnunnunnnnnunnunnnnnunnnnnnnunnnnn nun ann nun annnnnnnannnnnannnnnnnnnnnnnnnnnnnnnannnnnnnnn 7 OPERATING DETERMINATIONS cccccccccsceseccesescceeeeecsseeeeeueeeceenueeueneaueeeeueuseuauueusuesuuseseeauaseauauaeseenagseesanes 7 DESCRIPTION OF THE DEVICE z uu222u000000000n 0000000 nn nnnnnnnnnnunnunnnnnnnannnnnn nn nnnnn ann nun ann nun nn nnnnnnannnnnnnannnnnnnnnnnnn 8 EE 9 INS TALE ATION E 9 CLEANING AND MAINTENANCE uuu cece 1A 10 TECHNICAL SPEGIFIGATIONS ma a a aha aa AN Nad 10 Diese Bedienungsanleitung gilt fur die Artikelnummern This user
13. torisierten Fachhandel vorbehalten Achtung Nur die Pumpe und das Verbindungskabel Netzanschlusskabel d rfen mit Wasser in Ber hrung kommen nicht der Netzstecker Das Netzanschlusskabel sollte an mindestens einem Punkt tiefer h ngen Tropfschleife als die Pumpe und Netzsteckdose An diesem Punkt soll gegebenenfalls Wasser abtropfen und so nicht bis zur Steckdose gelangen Die Kombination von Wasser und Elektrizit t kann bei nicht vorschriftsm igem Anschluss oder unsachgem er Handhabung zu ernsthafter Gefahr f r Leib und Leben f hren Denken Sie immer daran dass Netzkabel zu Stolperfallen werden k nnen BESTIMMUNGSGEM SSE VERWENDUNG Bei diesem Ger t handelt es sich um einen Brunnen f r dekorative Zwecke Er wurde zur Verwendung in Innen und Au enr umen konzipiert Die Pumpe ist nur f r den Anschluss an 230 V 50 Hz Wechselspannung zugelassen Das Ger t ist wasserdicht Schutzart IP X8 und kann deshalb sowohl in Innenr umen als auch im Freien verwendet werden Um diese Schutzart zu gew hrleisten m ssen nach ffnen des Ger tes evil vorhandene Gummidichtungen auf Besch digungen berpr ft und ordnungsgem montiert werden Der Installateur muss sicherstellen dass bei Verwendung im Freien immer eine Gummischlauchleitung HOSRN F oder HOSRR F angeschlossen wird Bei Verlegung im Erdreich muss ein Erdkabel NYY verwendet werden Alle geltenden Vorschriften zur Installation von Kabeln im Freien bzw im Erdrei
14. ungen wie Staub usw gereinigt werden Verwenden Sie zur Reinigung ein fusselfreies angefeuchtetes Tuch Auf keinen Fall Alkohol oder irgendwelche L sungsmittel zur Reinigung verwenden Bitte entfernen Sie das Wasser vollst ndig wenn der Brunnen l ngere Zeit au er Betrieb genommen wird Ansonsten k nnen sich im Laufe der Zeit Algen und Bakterien bilden Entfernen Sie hierzu das gesamte Wasser aus dem Ger t Um das Restwasser das sich in den Mulden des Brunnens sammelt zu beseitigen ist ein wasseraufnehmendes Tuch oder ein Schwamm bestens geeignet Generell empfehlen wir den Brunnen in regelm igen Zeitabst nden zu Reinigen und Wasserwechsel durchzuf hren um das Wasser stets frisch zu halten Im Ger teinneren befinden sich keine zu wartenden Teile Wartungs und Servicearbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten Sollten einmal Ersatzteile ben tigt werden verwenden Sie bitte nur Originalersatzteile Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachh ndler jederzeit gerne zur Verf gung TECHNISCHE DATEN Spannungsversorgung 230 V AC 50 Hz Gesamtanschlusswert 8 W Ma e LxBxH ca 410 x 410 x 550 mm Gewicht ca 5kg Bitte beachten Sie Technische nderungen ohne vorherige Ank ndigung und Irrtum vorbehalten 08 09 2010 6 10 00053231 DOC Version 1 1 English USER MANUAL ton Fountain For your own safety please read this use
Download Pdf Manuals
Related Search
Related Contents
dossier - Ville d`Antony Manual De Instalación SmartStep 2 servo system USER'S MANUAL Manuel de l`opérateur manual 25HCB3 - HVACpartners Guía rápida Additional Explanation for A851GOT Graphic こちらの文書[PDF 327KB] Copyright © All rights reserved.