User's Manual for Applied Microsystems Ltd SV Plus V2

image

Contents

1. 2 26 4X 2 09 2 54 2 54 210 10 GROUND SHIELD e MEMORY g ao 16 54 21 59 TRANSMIT BLACK 65 85 POWER 12V RED ff f OO GROUND BLACK WIRES TTL RECEIVE WHITE TRANSMIT GREEN POWER RED 4 63 18 1 3E 1 O Z VAN NI L i AS Xchange OEM Specifications Da 4 Xchange your old ideas 2071 Malaview Ave Sidney B C Canada V8L 5X6 Ph 250 656 0771 Fax 250 655 3655 THIS DRAWING CONFORMS TO ASME Y14 5 2009 DRAWN DATE DRAWING NO REV AML NO DIMENSIONS AND TOLERANCES UNLESS OTHERWISE SPECIFIED 01 10 SNP GQ 03297 B UNSPECIFIED B FIXED WIRING TTL INTERFACE DO 25NOV2013 HES INMI ORIGINAL SCALE 1 1 REVISION DATE MATERIAL ADDED SHEET 3 TTL INTERFACE B P 20 03 12 FRACTIONS 21 92 HOLE DEPTHS GIVEN FOR 20 12 N A c ACE SIZES 0 015 0 381 FULL DIAMETER SLD FILE NO SHEET NO REV DESCRIPTION BY DATE 020 Sanco SURFACE FINISH 63 Ot 3 SIZE B SNP GO 03297 Sheet 3 of 3 8 7 6 T 4 3 2 8 7 6 5 4 3 2 1 THE INFORMATION CONTAINED THIS DRAWING IS THE SOLE PROPERTY AML OCEANOGRAPHIC ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF AML OCEANOGRAPHIC
2. POWER 12V apa Ie ir 2 64 77 WIRE ENTRY THIS SIDE 2 550 2 54 12 100 47 TURBIDITY XCHANGE COMMUNICATIONS PCB 21 22 WIRE PADS 84 esr 000 I hb 5 33 210 MOUNTING PT OR STANDOFFS TURBIDITY XCHANGE SENSOR PCB VAN L S lt Turbidity Xchange OEM Specifications OCEANOGRAPHIC your old ideas 2071 Malaview Ave Sidney B C Canada V8L 5X6 Ph 250 656 0771 Fax 250 655 3655 THIS DRAWING CONFORMS TO ASME Y14 5 2009 DRAWN DATE DRAWING NO REV AML DIMENSIONS AND TOLERANCES UNLESS OTHERWISE SPECIFIED 04 12 SNTU GA 03600 A UNSPECIFIED ORIGINAL SCALE 1 1 REVISION DATE MATERIAL RUE FRACTIONS 1 32 HOLE DEPTHS GIVEN FOR A FIXED TTL WIRING DIAGRAM DO 25NOV2013 GESS FULL DIAMETER SID FENG SHEETRO REV DESCRIPTION BY DATE 0200 Sanco SURFACE FINISH 63 Ot 3 SIZE B SNTU GA 03601 Sheet 2 of 3 3 2 8 7 THE INFORMATION CONTAINED THIS DRAWING IS THE SOLE PROPERTY AML OCEANOGRAPHIC ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF AML OCEANOGRAPHIC IS PROHIBITED 6 POWER 12V RED GROUND SHIELD MEMORY WHITE TRANSMIT BLACK TURBIDITY XCHANGE ELECTRONICS OVERVIEW 2 54 10 TTL INTERFACE
3. 2 26 4X 0 09 2 54 10 16 51 21 59 65 85 4 63 74 WIRES TTL GROUND BLACK RECEIVE WHITE TRANSMIT GREEN POWER RED MRL S L OCEANOGRAPHIC M ANS your old ideas 2071 Malaview Ave Sidney B C Canada V8L 5X6 Ph 250 656 0771 Fax 250 655 3655 TITLE Turbidity Xchange OEM Specifications THIS DRAWING CONFORMS TO ASME Y14 5 2009 DIMENSIONS AND TOLERANCES UNLESS OTHERWISE SPECIFIED FIXED TTL WIRING DIAGRAM DO 25NOV2013 REV DESCRIPTION BY DATE UNITS INCHES MM ANGLES 1 FRACTIONS 1 32 HOLE SIZES 0 005 0 13 0 00 0 015 0 38 0 000 0 005 0 13 ORIGINAL SCALE 1 1 HOLE DEPTHS GIVEN FOR FULL DIAMETER SURFACE FINISH e3 DRAWN DATE DRAWING NO REV AML NO I L 04 DEC 12 SNTU GA 03600 A UNSPECIFIED REVIEWED DATE MATERIAL N A SLD FILE NO SHEET NO GO SIZE B SNTU GA 03601 Sheet 3 of 3 3 2
4. DISPLAY SAMPLE RATE Displays the time based sampling rate SET SAMPLE nt Sets the desired sampling rate n is a number and t is the time units Examples are SETSC sets the sampling to continuous 25 Hz SET 5 s 5 samples per sec SETS 1s 1 sample per second SET S 2 m 2 samples per minute SETS5m 1 sample every 5 minutes SET S 2 h 2 samples per hour SETS 24h 1 sample every 24 hours Output format commands DISPLAY STARTUP Displays the power up output settings SET LATITUDE Sets the current latitude within a range of 90 to 90 dd dddddd degrees Latitude is used in calculating depth from pressure Contact AML Sales for more information on the equation SET PRESSURE UNITS Sets units for real output to Where x y psi xly metres feet When changing units to feet or metres the user must set latitude as the depth calculation corrects for surface gravity Contact AML Sales for more information on the equation SET TEMPERATURE Set units for real output to x y Where celsius UNITS fahrenheit SET STARTUP Sets the instrument to wait for user commands on power up PROMPT SET STARTUP SCAN Sets the instrument to output one scan on power up and then wait for a user command SET STARTUP Sets the instrument to start monitoring data on power up MONITOR SET STARTUP Disables the instrument identification header output on NOHEADER power up SET STARTUP Enables the instrument
5. OEM Xchange Secondary Mount User Manual Version 1 72 29 May 2014 Revision Date of Changes Name Revision 1 6 06 Feb 2013 Added NMEA like output Dustin Olender 1 7 19 June 2013 Updated current consumption Dustin Olender 1 71 07 Oct 2013 NMEA Added change units commands Dustin Olender 1 72 29 May 2014 Edited page number references Jehan Zouak User Manual for AML Oceanographic s OEM Xchange Secondary Mount Table of Contents General Description of the Instrument 2 Shipping amp aaa utem ceto tet a 4 Receiving an or eset a 4 Returning an Instrument to the 2 44 4 4 4 5 he Instfumenfa 6 Installation 6 Pressure E 6 e Oe ne 6 Configuring Sampling Parameters using SeaCast seen 7 Selecting an instrument for configuration eet nnne 7 Configuring the Selected 8 Instrument time memory amp log file settings 22 2 9 Configuring Sampling Parameters with HyperTerminal seen 9 Monitoring Real Time Data 11 Post Deployment Pro
6. 8 7 THE INFORMATION CONTAINED THIS DRAWING IS THE SOLE PROPERTY OF AML OCEANOGRAPHIC 6 ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF AML OCEANOGRAPHIC IS PROHIBITED T XCHANGE ELECTRONICS WIRES TO RS 232 POWER RED TRANSMIT GREEN 8 16VDC RECEIVE WHITE GROUND BLACK I 2 54 100 71 37 16 51 2 810 650 GROUND do MEMORY WHITE 21 59 TRANSMIT BLACK 5 85 POWER 12V O 1 84 70 2 64 77 WIRE ENTRY THIS SIDE _ 2 54 2 550 12 100 47 COMMUNICATIONS PCB 21 22 P XCHANGE 84 WIRE PADS X conr e i 1 d mr 5 33 210 MOUNTING STANDOFFS XCHANGE SENSOR VAN LD S T Xchange OEM Specifications OCEANOGRAPHIC AAR your old ideas 2071 Malaview Ave Sidney B C Canada V8L 5X6 Ph 250 656 0771 Fax 250 655 3655 THIS DRAWING CONFORMS TO ASME Y14 5 2009 DRAWN DATE DRAWING NO REV AML NO DIMENSIONS AND TOLERANCES UNLESS OTHERWISE SPECIFIED 01 10 SNT GA 03353 B UNSPECIFIED B FIXED TTL WIRING DI
7. lt P Xchange OEM Specifications OCEANOGRAPHIC A Xchange your old ideas 2071 Malaview Ave Sidney B C Canada V8L 5X6 Ph 250 656 0771 Fax 250 655 3655 THIS DRAWING CONFORMS TO ASME Y14 5 2009 DRAWN DATE DRAWING NO REV DIMENSIONS TOLERANCES UNLESS OTHERWISE SPECIFIED I L FEB 01 10 SNP GQ 03297 B UNSPECIFIED B FIXED WIRING TTL INTERFACE DO 25NOV2013 UNTS pee iM ORIGINAL SCALE 1 1 REVISION DATE MATERIAL 20 12 A ADDED SHEET 3 TTL INTERFACE 20 03 12 GE GOES 20 2 064 FULL DIAMETERS 0 00 0 015 0 38 SLD FILE NO SHEET NO REV DESCRIPTION BY DATE 0 000 0 005013 SURFACE FINISH 63 Qra39 SIZE B SNP GQ 03297 Sheet 1 of 3 1 N 4 3 2 8 7 6 5 4 3 2 THE INFORMATION CONTAINED THIS DRAWING IS THE SOLE PROPERTY AML OCEANOGRAPHIC ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF AML OCEANOGRAPHIC IS PROHIBITED P XCHANGE ELECTRONICS WIRES TO RS 232 POWER RED n TRANSMIT GREEN 8 16VDC RECEIVE WHITE GROUND BLACK 2 54 100 71 37 16 51 2 810 650 GROUND ae MEMORY
8. 3B AML TUN 514 4 SN 600013 3C AML TUN 514 2 SN 600013 3A User Manual for AML Oceanographic s OEM Xchange Secondary Mount AML TUN 514 1 SN 600013 39 gt set nmeaoff NMEA like output disabled gt monitor 514 6 514 8 514 9 515 1 gt set automonitor 10 Automonitor set to10 sec User Manual for AML Oceanographic s OEM Xchange Secondary Mount Customer Support Troubleshooting Instrument fails to communicate e Check the cables o ls the data power cable connected to the circuit board terminal block and computer Are there any cuts in the cable f powering over a long cable check the voltage drop over the cable Measure the voltage at the circuit boards The voltage must be above 8 volts Are the communication settings in the program used on the computer correct o Comm port selection o 8bits o 1 stop bit o No parity o No hardware handshaking o Baudrate between 600 and 38 400 baud Are the communication settings in the instrument correct Was the instrument specifically set to one baud rate last time If so the user must use that baud rate to resume communications o Was the instrument set to RX OFF last time If so a carriage return must be sent to the instrument immediately after power is applied to interrupt this mode o Was the instrument set to monitor on power up mode If so a carriage return must be sent to the instrument immediately after power is applied to interru
9. 500 1000 2000 Pressure Xchange 4000 5000 amp 0 05 FS 0 003 5 0 002 FS 10 ms 6000 dbars a 100 400 1000 up to up to up to lt 0 7s change 3000NTU 395 NTU 3 NTU 4 0 5NTU 3s to 95 Pre Release Specifications Final Specifications to be determined Electrical Communications Board 5 232 Comm board or RS 485 Comm board TTL single board Sensor Boards PxTx Xchange sensor board e Factory set RS232 or RS485 7 duplex ASCII Autobaud to 38 400 Power External Power Supply Comms Configuration Voltage range R25 or RSA Bo 26 VOC 6016700 Current Consumption Temperature Xchange 23 User Manual for AML Oceanographic s OEM Xchange Secondary Mount Sampling Capabilities e Frequency Time selectable sample rates from 25 per second to 1 per hour e Configurations Single scan or continuous output command or autonomous on power up Included Items Xchange Secondary Mount e Secondary Blanking Plug CD with manuals and documentation Software e SeaCast 24 User Manual for AML Oceanographic s OEM Xchange Secondary Mount Ordering Codes Instruments PDC OEX SV 232 OEM Xchange SV Mount and Electronics for RS 232 Communications PDC OEX SV 485 OEM Xchange SV Mount and Electronics for RS 485 Communications PDC OEX SV TTL OEM Xchange SV Mount and Electronic
10. IS PROHIBITED P T Xchange Blanking Plug AML No PLS SU009 8 89 i 350 2 2 015 700 O RINGS Xchange Sensor Weight 65 grams 08 3 63 112 40 4 43 2X 2 015 N70D O RINGS 16 1 66 SCALE 1 5 1 15 8 0076 62 48 2 46 625 003 0 51 R 020 T Xchange Titanium Bulkhead AML Part No SUB G0581 Weight 50 grams 20 07 gt 790 24 13 7 950 2 111 N70D O RING 95 B LEAVE SUFFICIENT THICKNESS FOR FORCES GENERATED AT DESIGN PRESSURE T Xchange SENSOR ASSEMBLY BLANKING PLUG ASSEMBLY MOUNTING REQUIREMENTS VAN L Xchange OEM Specifications OCEANOGRAPHIC A Xchange your old idees 2071 Malaview Ave Sidney B C Canada V8L 5X6 Ph 250 656 0771 Fax 250 655 3655 THIS DRAWING CONFORMS TO ASME Y14 5 2009 DRAWN DATE DRAWING NO REV AML NO DIMENSIONS AND TOLERANCES UNLESS OTHERWISE SPECIFIED I L FEB 01 10 SNT GA 03353 B UNSPECIFIED B FIXED TTL WIRING DIAGRAM DO 25NOV2013 UNITS INCHES MM ORIGINAL SCALE 1 1 REVISION DATE MATERIAL FRACTIONS 1 32 HOLE DEPTHS GIVEN FOR B P MAR 20 12 N A A ADDED SHEET 3 TTLINTERFACE B P 20 03 12 HOLE SIZES 0009019 E DoD o Es REV DESCRIPTION BY DATE 0905 0215035 SURFACE FINISH 63 7 Ot 3 SIZE B SNT GA 03353 Sheet 1 of 3 T N 4 3 2
11. WHITE 948 21 59 TRANSMIT BLACK 85 er POWER 12V RED O if 24154 WIRE ENTRY THIS SIDE 2 54 12 100 47 COMMUNICATIONS 21 22 P XCHANGE 84 WIRE PADS x VUVV_ e d i3 d 5 33 210 MOUNTING PT OR STANDOFFS P XCHANGE SENSOR PCB Z VAN S lt P Xchange OEM Specifications OCEANOGRAPHIC your old ideas 2071 Malaview Ave Sidney B C Canada V8L 5X6 Ph 250 656 0771 Fax 250 655 3655 THIS DRAWING CONFORMS TO ASME 14 5 2009 DRAWN DATE DRAWING NO REV AML DIMENSIONS AND TOLERANCES UNLESS OTHERWISE SPECIFIED 01 10 SNP GQ 03297 B UNSPECIFIED B FIXED WIRING TTL INTERFACE DO 25NOV2013 UNITs INCHES MM ORIGINAL SCALE 1 1 REVISION DATE MATERIAL A ADDED SHEET 3 TTL INTERFACE B P 20 03 12 FRACTIONS 182 HOLE DEPTHS GIVEN FOR 20 12 N A 1 2 0 018 0 33 FULL DIAMETER SLD FILE NO SHEET NO REV DESCRIPTION By pae SURFACE FINISH 63 SIZE B SNP GQ 03297 Sheet 2 of 3 7 3 2 8 7 THE INFORMATION CONTAINED THIS DRAWING IS THE SOLE PROPERTY OF AML OCEANOGRAPHIC ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF AML OCEANOGRAPHIC IS PROHIBITED 6 5 4 3 XCHANGE ELECTRONICS OVERVIEW TTL INTERFACE
12. identification header output on HEADER power up SET NMEAON Turns NMEA like format on SET NMEAOFF Turns NMEA like format off SET AUTOMONITOR x Automatically starts MONITOR after x seconds of command line inactivity 0 lt lt 255 If x0 AUTOMONITOR is disabled FORMAT ab Changes the numerical output format of the sensor Where Any sensor xxxxx sensor type TEMPERATURE TURBIDITY or PRESSURE a number of digits ahead of the decimal place b number of digits after the decimal place General commands SCAN Measure and output one scan of data User Manual for AML Oceanographic s OEM Xchange Secondary Mount MONITOR Scan at the set sampling rate VERSION Displays the instrument identification header DISPLAY OPTIONS Displays the instrument status and user settings ZERO ON Corrects the barometric offset to set zero pressure at surface for current barometric pressure ZERO OFF Disables barometric offset Checks each slot in logger board to identify what is plugged in and displays sensor board type amp serial number or empty for each slot 22 User Manual for AML Oceanographic s OEM Xchange Secondary Mount Technical Specifications Sensors Secondary Xchange Sensors ime TemperaturesXchange 2 C to 32 C 0 005 C 0 003 C 0 001 C TemperaturesXchange 5 C to 45 C 0 008 C 0 004 C 0 001 C 50 100 200
13. instrument to turn the instrument on Release the ENTER key once the prompt gt is displayed Using the terminal emulation program issue the following commands to disable data on power up SET STARTUP HEADER enables the power up header information o SET STARTUP PROMPT disable data output on power up o SET SAMPLE RATE 10 S selects the desired sampling rate o SET DETECT A7 set 10 autobaud attempts then default to 38400 baud Note details on the SET DETECT command can be found in the appendix Unplug the data power cable from the instrument to turn the instrument off User Manual for AML Oceanographic s OEM Xchange Secondary Mount Maintaining the Instrument Periodic Maintenance Periodic maintenance will prolong the life of the instrument The following is recommended e f the Xchange sensor is very dirty or oily use warm soapy water and allow the instrument to soak before cleaning with a rag or soft brush Rinse with fresh water e Before each use o Check the tightness of the swappable sensor o Check for nicks and cuts on the cable If you are using a cable on this application e After each use o Clean and rinse the Xchange using fresh water Dry and safely store the instrument e Yearly o Send the instrument or Xchange sensors to a service centre for diagnostics and re calibration User Manual for AML Oceanographic s OEM Xchange Secondary Mount Communications PC Settings The OEM Xc
14. salt deposits o Check the circuit boards for damage Check the Xchange sensor is installed tightly The blue retaining ring should be within 1 mm of the instrument end cap Connect the instrument to a computer with the data cable and perform a scan or monitor if using SeaCast User Manual for AML Oceanographic s OEM Xchange Secondary Mount Returning an Instrument to the Factory f shipping for repair or recalibration obtain an RMA number from the service centre e Pack the instrument in its original shipping box if possible to prevent damage during shipping An RMA number can be requested using any of the following contact options Service Department Email service AMLoceanographic com Phone 1 250 656 0771 Phone 1 800 663 8721 NA Fax 1 250 655 3655 Website http www AMLoceanographic com Customer Portal RMA requests may also be submitted through My AML Oceanographic once logged in or by navigating to the Support tab on the AML Oceanographic website Mailing and Shipping Address AML Oceanographic 2071 Malaview Ave Sidney BC Canada V8L 5X6 User Manual for AML Oceanographic s OEM Xchange Secondary Mount Using the Instrument Installation Refer to OEM specification drawings at the end of this manual for mounting details Pressure Ratings Pressure ratings are given for both the P Xchange and TurbidityeXchange sensors and the OEM sensor bulkhead The sensor bulkhea
15. 2009 DRAWN DATE DRAWING NO REV AML NO DIMENSIONS AND TOLERANCES UNLESS OTHERWISE SPECIFIED I L FEB 01 10 SNT GA 03353 B N A B FIXED TTL WIRING DIAGRAM DO 25NOV2013 dee ORIGINAL SCALE 1 1 cio TA em MATERIAL m FRACTIONS 1 32 ADDED SHEET 3 TTL INTERFACE 20 03 12 HOLE SIZES 00080243 AEDE GIVEN FOR REV DESCRIPTION BY DATE 0 000 00020 18 SURFACE FINISH e3 GO SIZE B SNT GA 03353 B Sheet 3 of 3 8 7 f 4 3 2 1 8 7 THE INFORMATION CONTAINED THIS DRAWING IS THE SOLE PROPERTY AML OCEANOGRAPHIC ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF AML OCEANOGRAPHIC IS PROHIBITED 28 70 51 13 B Turbidity Xchange Sensor Assembly Turbidity Xchange AML No XCH TRB 0100 XCH TRB 0400 XCH TRB 1000 XCH TRB 3000 Weight in Air 134 g Weight in Water 85 g Secondary Mount Titanium Bulkhead AML Part No SUB G0581 Weight in Air 50 g Weight in Water 43 g 2 111 N70D O RING 2X 2 015 N70D O RINGS Secondary Blanking Plug AML No SUB G0678 Weight in Air 18 g Weight in Water 5 g Blanking Plug Assembly SECTIO SCALE N B B 1 5 1 158810076 003 625 003 0 51 R 020 20 07 790 LEAVE SUFFICIENT THICKNESS FOR FORCES GENERATED AT DESIGN PRESSURE Mounting Requirements NIL change your old ideas 2071 Malaview Ave Sidney B C
16. AGRAM DO 25NOV2013 ORIGINAL SCALE 1 1 REVISION DATE MATERIAL ADDED SHEET 3 TTL INTERFACE 20 03 12 FRACTIONS gt 192 DEPTHS GIVENFoR MAR 20 12 a 0 018 0 33 FULL DIAMETER SLD FILE NO SHEET NO REV DESCRIPTION BY DATE 200 SURFACE FINISH 63 Ot 3 SIZE B SNT GA 03353 Sheet 2 of 3 f i 3 2 8 7 THE INFORMATION CONTAINED THIS DRAWING IS THE SOLE PROPERTY OF AML OCEANOGRAPHIC 6 ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF AML OCEANOGRAPHIC IS PROHIBITED T XCHANGE ELECTRONICS OVERVIEW TTL INTERFACE 2 54 10 2 26 4X 0 09 2 54 10 GROUND SHIELD MEMORY WHITE g 56 16 51 21 59 TRANSMIT BLACK 65 85 POWER 12V RED 19 GROUND BLACK WIRES TTL RECEIVE WHITE TRANSMIT GREEN jas Sa A 4 63 POWER RED 18 r 1 IA 1 qm 1 vA N L Ao pm T Xchange OEM Specifications Xchange your old ideas 2071 Malaview Ave Sidney B C Canada V8L 5X6 Ph 250 656 0771 Fax 250 655 3655 THIS DRAWING CONFORMS TO ASME Y14 5
17. Canada V8L 5X6 Ph 250 656 0771 Fax 250 655 3655 Turbidity Xchange OEM Specifications THIS DRAWING CONFORMS TO ASME Y14 5 2009 DRAWN DATE DRAWING NO Bee JAME NO DIMENSIONS AND TOLERANCES UNLESS OTHERWISE SPECIFIED IL 04 Dec 12 SNTU GA 03600 A UNSPECIFIED A A ORIGINAL SCALE 1 1 REVIEWED DATE MATERIAL FRACTIONS 1 32 HOLE DEPTHS GIVEN FOR A FIXED TTL WIRING DIAGRAM DO 25NOV2013 SIZES 0 018 0 33 FULL DIAMETER SLD FILE NO SHEET NO REV DESCRIPTION BY DATE 0 000 0 005 0 13 SURFACE FINISH 63 5 5 5 2 SNTU GA 03601 4 3 2 Sheet 1 of 3 THE INFORMATION CONTAINED THIS DRAWING IS THE SOLE PROPERTY AML OCEANOGRAPHIC 8 7 6 ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF AML OCEANOGRAPHIC IS PROHIBITED TURBIDITY XCHANGE ELECTRONICS OVERVIEW 71 37 RS 232 INTERFACE WIRES TO RS 232 2 810 POWER RED TRANSMIT GREEN 8 16VDC RECEIVE WHITE GROUND BLACK __ 2 54 100 16 51 650 MEMORY WHITE TRANSMIT GROUND Menge o 32 he
18. able The voltage drop on a standard AML cable with a standard OEM Xchange Secondary Mount is about 1 volt per 100m of cable The instrument s lowest voltage is 8 volts o The instrument s maximum voltage is 16 volts o The voltage at the instrument while sampling must be above the shutdown level for the instrument to operate If using a PressuresXchange sensor with the instrument in air use the zero command to zero the barometric pressure offset Begin monitoring data using SeaCast or HyperTerminal E SeaCast Instrument Setup View Data Display Mode O Table Data Vertical Position Cast Information Type Micro X Turbidity SN 065535 Firmware 1 03 SampleUnts continuous SampleInterval 0 dsvPi6 re Capture to fie Gear oss Post Deployment Procedures When the instrument is pulled from the water it should be rinsed in fresh water If applicable dry the area around the connectors with a clean cloth or compressed air prior to disconnecting the plugs or cables Do not blow compressed air into the PressuresXchange sensor Remove the data power cable Place dummy plug in the connector to protect it Dry the instrument and stow it securely User Manual for AML Oceanographic s OEM Xchange Secondary Mount Configuring the Instrument for Data on Power Up Perform the following steps Open a terminal emulation program such as HyperTerminal a
19. cedures a etel M attore eI a ent I NN IRE 11 Configuring the Instrument for Data on Power Up sss 12 Disabling Data on Power TD bita oq ett ete tede 12 Maintaining 13 PerodicMalnteriarie sf etm tices E 13 bb teet etn ON oe 14 PG Se MINS e E 14 Q tp t 14 us sedeo peto 14 1 E Og stc adipisi AUGERE die eC SELBE 15 NMEAclike zu a a oa aa GRO eaae ed Ga a deba ee d RR 16 GUSLOMEN SUPPO sat toe D 18 18 AML Oceanographic Contact Info aes qe 19 20 Gi I eM EE 20 Communications cos aiat bi e n bl te bm pesti tenis 20 Sampling rate comma nds u oo Dd eeu t escena mtb a UE 21 21 General COMM 21 Technical Specification S accio odo od pia tori 23 cote 26 OEM Xchange Secondary Overview Drawings sees 27 User Manual for AML Oceanographic s OEM Xchange Secondary Mount General Des
20. cription of the Instrument The AML Oceanographic X series instruments and sensors provide a major advancement in ocean instrumentation The swappable and interchangeable sensor technologies dramatically improve the capabilities of ocean instrumentation These capabilities include e Changing the instrument sensor types while at sea within seconds and without tools For example the same instrument can be changed from a CTD to a sound speed profiler e The sensor ranges can be swapped as sampling conditions change to maximize the instrument s resolution and accuracy For example a deep pressure sensor be swapped for a shallow pressure sensor and the salt water conductivity sensor can be swapped for a fresh water conductivity sensor e Sensors from one instrument can be swapped to another instrument to maintain mission critical capabilities e Calibrated sensors can be sent to the instrument so that the instrument does not need to be removed from service for calibration e Spare sensors ensure that an instrument can be immediately returned to service after catastrophic damage such as a high speed impact with the ship s hull All calibration and traceability data resides within each sensor There is no need update instrument configuration files or coefficients Calibration data for all sensors is instantly available from the instrument and calibration certificates can be printed from AML 5 SeaCast software
21. d for deployment using HyperTerminal or other terminal emulation programs HyperTerminal will need to be used for TTL As with SeaCast communications with the instrument must be established using the correct communications port User Manual for AML Oceanographic s OEM Xchange Secondary Mount and settings The communications settings are 8 data bits 1 stop bit no parity no flow control and the desired baud rate The sampling parameters can be programmed by entering text commands The following are examples SET SAMPLE RATE CONTINUOUS Sets the sample rate to as fast as possible 25 Hz SET SAMPLE RATE 5 s Sets the sample rate to 5 samples per second SET P INC 1 Sets the sample rate to pressure increments of 1 dbar SET SOUND INC 2 Sets the sample rate to sound speed increments of 2 m s Please consult the Commands section of the Appendix for full syntax details on how to issue the commands in question Please note that the above are example commands only many additional sampling regimes can be established User Manual for AML Oceanographic s OEM Xchange Secondary Mount Monitoring Real Time Data Ensure the pre deployment procedures have been done see Page 6 Ensure that the desired sampling requirements have been selected and applied Plug the data power cable into the instrument If you power the instrument over a long cable please note the following The longer the cable the higher the voltage drop on the c
22. d is rated to 6000 dBar however it is important to know what the rating is on your sensor Deployments should never exceed the lower of these pressure ratings Caution Do not exceed the specified pressure ratings of the P Xchange sensor TurbiditysXchange sensor or the OEM sensor bulkhead Overpressure can result in damage to the sensors and the bulkhead TurbiditysXchange sensors are limited to deployments of 500m depth It is desirable to optimize the accuracy of pressure measurements by using a sensor with a pressure range that closely matches the depth of the deployment Pre Deployment Procedures e Upon Receipt o Use the receiving steps above to verify the instrument is in good working order Verify the calibrations of all sensors are valid for the duration of the deployment If not swap the Xchange sensors for sensors with valid calibrations or send the Xchange sensors to a service center for recalibration o Verify that the pressure range for either the T Xchange PeXchange and TurbiditysXchange sensor being used is appropriate for the depth of the deployment Caution Install blanking plugs in all unused sensor ports prior to deployment Failure to install blanking plugs will result in damage to the connectors T Xchange PsXchange amp TurbiditysXchange Blanking Plug User Manual for AML Oceanographic s OEM Xchange Secondary Mount e intent o
23. f an OEM product is to offer integration and flexibility for the manufacturer Please consult AML for guidance or assistance with your specific application e Ensure bulkhead and electronics are secure Configuring Sampling Parameters using SeaCast AML Oceanographic s SeaCast application software greatly simplifies the process of setting up an instrument to complete a profile Full details on the instrument configuration process can be found in the SeaCast manual Below please find a quick summary of that process e Note that for OEM integration SeaCast is not required However SeaCast offers a good overview of what is possible with the AML API Please consult AML for more information Selecting an instrument for configuration On the Instrument Tab the first row of fields Port Baud Rate and Status control and display the communications with the instrument Ei SeaCast fex como Detectinstument T 065535 Type Sensor Calbrated TU Xchange 600013 11 27 12 0 514 0 3000 NTU I nt Cer fic Print Certificate The Port field allows the user to select the computer communications to which the instrument is connected If uncertain about the port the user can check the ports in the Device Manager or Hardware Manager found in the control panel in the Windows operating system The Refresh selection at the bottom of the l
24. ge Secondary Mount manual which provides an overview on how to use and maintain the instrument A software manual ie SeaCast which provides instructions on how to use the software to configure the instrument and review instrument data e Xchange sensor manuals T Xchange PsXchange TurbiditysXchange and which provide overviews on how to install and maintain each of the Xchange sensors If you are configuring a sensor for field use or lab test we recommend that you begin with the software SeaCast manual If you are focused on instrument maintenance we recommend that you begin with the instrument manual If you are wishing to swap an Xchange sensor we recommend that you read the appropriate Xchange manual User Manual for AML Oceanographic s OEM Xchange Secondary Mount Shipping amp Receiving Receiving an Instrument When an instrument is received at a new location it is prudent to perform the following steps to ensure the instrument is capable of performing when required Check the shipping container for signs of damage This could indicate damage to the instrument inside The shipping package should include all of the following items o Electronics board set 2 circuit boards if RS 232 or RS 485 and 1 for TTL o One sensor bulkhead connector o sensor port blanking plug CD with manuals and documentation Check for damage o Check the connector sockets for corrosion dirt and
25. hange Secondary Mount will communicate with either RS 232 RS 485 or TTL serial connections depending on how the instrument was ordered from the factory The computer to which the instrument is connected must be set up as follows 8 bits 1 stop bit No parity No hardware handshaking Baud rate of 600 1200 2400 4800 9600 19 200 or 38 400 baud default After power up the OEM Xchange Secondary Mount will wait for an ASCII carriage return The instrument will automatically detect the baud rate when the enter key is depressed Output Formats Output formats can be modified by the user If the modifications required are not supported by the commonly used command list in the next section please contact the factory for assistance The user can change e The number of decimal places for each channel e Turn on or off power up information header e Turn on or off automatic monitoring on power up Default output format The output from the OEM Xchange Secondary Mount is space separated values There are commands to change the delimiter to tab or comma separated values if required The following table shows the output units for each Xchange sensor Sensor Units Default Format Notes dBar 1234 56 TemperaturesXchange 12 345 TurbiditysXchange NTU 12 3 User Manual for AML Oceanographic s OEM Xchange Secondary Mount Example outputs Exa
26. ist allows the user to force a new detection of available ports This is useful if a USB connection is made after SeaCast is launched User Manual for AML Oceanographic s OEM Xchange Secondary Mount The Baud Rate field is used to select the baud rate the user wishes to use while communicating to the instrument Lower baud rates allow longer cables to be used if using RS 1920 232 485 422 Higher baud rates shorten the data transfer times Choose 38 400 baud rate UN default whenever possible If an instrument is set to autobaud default setting it will detect the baud rate chosen in SeaCast and communicate at that baud rate If the baud rate is changed in SeaCast then power to the instrument must be cycled to re establish communications at the new baud rate Some instruments are set up to communicate at fixed baud rates In this mere C Status case the baud rate SeaCast must be set to the same baud rate as the instrument If the instrument baud rate is unknown the Scan switch o below the Baud Rate field can be used to have SeaCast cycle through Son all the baud rates to try to detect the instrument baud rate Status The Status field shows the status of the communications with the instrument The green light indicates that communications have been established with the Sans instrument During the identification process SeaCast is determining the type and Q serial nu
27. l This warranty is the only warranty given by AML No warranties implied by law including but not limited to the implied warranties of merchantability and fitness for a particular purpose shall apply In no event will AML be liable for any direct indirect consequential or incidental damages resulting from any defects or failure of performance of any instrument supplied by AML 26 User Manual for AML Oceanographic s OEM Xchange Secondary Mount OEM Xchange Secondary Overview Drawings 27 8 7 6 5 4 3 2 1 THE INFORMATION CONTAINED THIS DRAWING IS THE SOLE PROPERTY AML OCEANOGRAPHIC ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF AML OCEANOGRAPHIC IS PROHIBITED P T Xchange Blanking Plug AML No PLS SU009 ae 35 D 2 2 015 N70D O RINGS Weight 65 grams 75 06 2 96 2X 2 015 N70D O RINGS i 95 38 3 76 16 SECTION 1 66 SCALE 1 5 1 8 0076 C 62 48 5154 _ EE 2 46 5 625 003 0 51 Xchange Titanium Bulkhead 000 R 020 AML Part No SUB G0581 Weight 50 grams 20 07 I 24 13 as 0 950 2 111 N70D O RING 24 13 I 950 LEAVE SUFFICIENT THICKNESS FOR FORCES GENERATED AT DESIGN PRESSURE P Xchange SENSOR ASSEMBLY BLANKING PLUG ASSEMBLY MOUNTING REQUIREMENTS Z A NI L ii
28. mber of the instrument and any connected sensors During the settings process SeaCast is determining the latest sampling and logging settings that ras were programmed into the instrument When all the required handshaking has 9 been completed the Status field will show Connected and the user may use the instrument Please note that the handshaking can take up to 30 seconds to complete The Detect Instrument button forces SeaCast to re detect and re identify the instrument and its sensors Configuring the selected instrument After the instrument has been detected by SeaCast select the Setup tab at the top of the SeaCast window User Manual for AML Oceanographic s OEM Xchange Secondary Mount The box in the upper left of the Setup page controls the sampling of the instrument For the OEM Xchange Secondary Mount only the time increment sampling method is available sample at 25 times per second 10 times per hour every 5 seconds etc The continuous selection sets the instrument to sample as fast as possible For the OEM Xchange Secondary Mount this is 25 Hz Sampling Method Selection Tab Instrument time memory amp log file settings The OEM Xchange Secondary Mount does not contain batteries internal memory or a real time clock Therefore time stamps and data logging are not available Configuring Sampling Parameters with HyperTerminal Instruments can also be configure
29. mple outputs for a sound velocity Xchange sensor are shown below User inputs in the output capture shown below are in bold type Micro X Pressure Version 1 01 SN 007803 AML Oceanographic Ltd P Xchange Sensor SN 300239 Calibrated 01 26 12 Slot 1 gt scan 0000 16 gt monitor 0000 16 0000 16 0000 16 0000 16 0000 16 gt display options Instrument Type Micro X Pressure SN 007803 Firmware 1 01 SampleUnits continuous Samplelnterval 0 DisplayHeader yes StartupMode Prompt DetectionMode a5 RX on TrailingSpace on PressureFormat 42 TemperatureFormat 23 StartupRawReal Real PressureUnits dbar TemperatureUnits Celcius Latitude 45 000 PressureOffset 0 000 UsePressureOffset no AddressMode off AddressByte 09 SerialParity none SerialEcho on CommunicationsDelay 0 Channel 1 SensorName1 P Xchange Slot1 1 BoardSN1 007803 SensorSN1 300239 CalDate1 01 26 12 CalBy1 MT CalRange1 0 100 dbar CalAccuracy1 0 012 FS PA 1 239642E 01 PB 0 000000E 01 PC 0 000000E 01 PD 0 000000E 01 PE 1 874044E 03 PF 0 000000E 01 PG 0 000000E 01 PH 0 000000E 01 5 591269E 10 PJ 0 000000 01 15 User Manual for AML Oceanographic s OEM Xchange Secondary Mount PK 0 000000E 01 0 000000E 01 PM 3 744591E 16 gt NMEA like output format The OEM Xchange Secondary Mount can be configured to produce an output similar to that regulated by the National Marine Electronics Association or NMEA as f
30. n launch My AML Oceanographic will allow you to View and manage your assets instruments and sensors Consult instrument diagnostic summaries View and download calibration and conformity certificates View and manage your technical support cases Consult and download sales estimates sales orders and invoice copies View account balances and generate account statements Assess inventory availability at AML User Manual for AML Oceanographic s OEM Xchange Secondary Mount Appendices Commands When using SeaCast the command set is not usually necessary However text commands are available Below is a listing of commonly used commands Note that some commands are only be available on instruments equipped with the appropriate Xchange sensors Communications commands Note Board set will dictate whether communications are RS 232 RS 485 or TTL DISPLAY DETECT Displays the baud rate detection settings SET DETECT ab Sets the baud rate detection a sets the number of autobaud detection attempts before the instrument reverts to the default baud rate set by b Setting a 0 forces the instrument to a fixed baud rate determined by b 1 600 baud 4 4800 7 38400 baud 2 1200 baud 5 9600 baud 8 57600 baud 3 2400 baud 6 19200 baud 9 115200 baud 20 User Manual for AML Oceanographic s OEM Xchange Secondary Mount Sampling rate commands
31. nd ensure the serial port has been selected in the program If the instrument has been set to a specific baud rate with the SET DETECT command the terminal emulation program must be configured for that baud rate Connect the instrument to the computer using the data power cable supplied with the instrument Using the terminal emulation program issue the following commands to the instrument SETSTARTUPNOHEADER disables the power up header information SET STARTUP MONITOR enable data output on power up o SETSAMPLE RATE 10 S set the desired sampling rate SET DETECT 07 set fixed 38400 baudrate Note details on the SET DETECT command can be found in the appendix Unplug the data power cable from the instrument to turn the instrument off Plug the data power cable into the instrument to turn the instrument on Disabling Data on Power Up Perform the following steps Open a terminal emulation program such as HyperTerminal and ensure the serial port has been selected in the program If the instrument has been set to a specific baud rate with the SET DETECT command the terminal emulation program must be configured for that baud rate Connect the instrument to the computer using the data power cable supplied with the instrument Instrument data will stream through the terminal emulation program window Unplug the data power cable from the instrument to turn the instrument off Hold down lt ENTER gt Plug the data power cable into the
32. ollows AML TUN 301 2 SN 600013 38 where AML is always present TUN identifies the next value as turbidity in NTU and the sensor serial is also displayed identifies the end of the data and the following two characters are the NMEA checksum in hexadecimal It s calculated by XORing all the characters in the string except the and characters The following table lists all format codes Code Description Units PD Pressure deciBar PP Pressure psi PM Pressure meters PF Pressure feet TC Temperature celsius TF Temperature fahrenheit TUN Turbidity Nephelometric Turbidity Units SN Serial Number To configure NMEA like output the following commands are used with terminal emulation program such as Hyperterminal SET turns NMEA like format o SET NMEAOFF turns off NMEA like format The AUTOMONITOR command is often used when NMEA like output is enabled It allows MONITOR mode to be automatically entered after a period of no activity on the user terminal Time is 0 for no timeout i e the command line waits forever for a command to 255 seconds To configure AUTOMONITOR the following commands are used SET AUTOMONITOR 10 MONITOR starts after 10 sec of inactivity SET AUTOMONITOR 30 MONITOR starts after 30 sec of inactivity SET AUTOMONITOR 0 MONITOR deactivated Example outputs gt set nmeaon NMEA like output enabled gt monitor AML TUN 514 3 SN 600013
33. pt this mode Instrument generates noisy data Are the wires secure in the terminal block on the circuit boards e there noise on the power supply Switching power supplies are common sources of noise Nearby EMI sources such as electric motors can create noise If possible move the instrument and its cables away from the noise source Is the instrument securely fastened to prevent vibrations Is the TemperaturesXchange sensor damaged Is there something nearby affecting the water temperature Is there dirt in the Pressure Xchange sensor Is there something in the water flow ahead of the pressure sensor shedding vortices into the pressure sensor User Manual for AML Oceanographic s OEM Xchange Secondary Mount AML Oceanographic Contact Info Service To request an RMA or technical support Email service AMLoceanographic com Phone 1 250 656 0771 Fax 1 250 655 3655 Sales For all general sales inquiries Email sales AMLoceanographic com Phone 1 250 656 0771 Fax 1 250 655 3655 http Awww AMLoceanographic com My AML Oceanographic My AML Oceanographic is AML s on line data centre This secure area within our website is designed to offer one easy location for interested individuals and organizations distributors customers prospects and other members of our community to manage their interactions with AML The functionality within My AML Oceanographic is expected to evolve quickly Upo
34. s Direct TTL Communications Sensors XCH TMP n232 T Xchange Calibrated Sensor 2 to 32 C Range 245 Calibrated Sensor 2 to 45 C Range XCH TMP n545 T Xchange Calibrated Sensor 5 to 45 C Range XCH PRS 0050 PeXchange 50 dBar XCH PRS 0100 PeXchange 100 dBar XCH PRS 0200 PeXchange 200 dBar XCH PRS 0500 PeXchange 500 dBar XCH PRS 1000 PeXchange 1000 dBar XCH PRS 2000 PeXchange 2000 dBar XCH PRS 4000 PeXchange 4000 dBar XCH PRS 5000 PeXchange 5000 dBar XCH PRS 6000 PeXchange 6000 dBar XCH PRS 6000 T065 PeXchange 6000 dBar Extended temperature calibration from 0 65 XCH PRS 10000 PeXchange 10000 dBar XCH TRB 0100 TurbiditysXchange 100 NTU XCH TRB 0400 TurbiditysXchange 400 NTU XCH TRB 1000 TurbiditysXchange 1000 NTU XCH TRB 3000 TurbiditysXchange 3000 NTU 25 User Manual for AML Oceanographic s OEM Xchange Secondary Mount Warranty AML warrants the instrument for a period of two years from the date of delivery AML will repair or replace at its option and at no charge components which prove to be defective The warranty applies only to the original purchaser of the instruments The warranty does not apply if the instrument has been damaged by accident or misuse and is void if repairs or modifications are made by other than authorized personne
35. whenever the instrument is connected Logged data is stamped with sensor traceability and instrument configuration data So there is never a doubt about how the data was collected or the status of the sensor s calibration e Since only the sensors need to be returned for recalibration the shipping costs are dramatically reduced The OEM Xchange Secondary Mount is the miniature single sensor member of the X Series family It is externally powered and provides the data via cable Communications with the OEM Xchange Secondary Mount are accomplished with RS 232 RS 485 or TTL depending on what is ordered from the factory Sampling rates are programmable by time 25 Hz to every 24 hours The OEM Xchange Secondary Mount is equipped with only one Xchange sensor port Due to the interchangeability of Xchange any of the following sensors may be used with the secondary port 1 temperature pressure and turbidity An OEM Xchange Secondary Mount with a secondary Xchange sensor port cannot accept Xchange sensors designed for a primary port and vice versa For information the use of sound velocity and conductivity sensors please refer to the OEM Xchange Primary Mount User Manual User Manual for AML Oceanographic s OEM Xchange Secondary Mount Which Manual Do Start With AML Oceanographic s Xchange instruments are shipped with several manuals on the CD e Aninstrument manual ie This OEM Xchan