UTROSb Heating Thermostat User Manual
Contents
1. minutes and set temperature Press Aor V to modify the value If you want to turn off a period please press V until the OFF shows ah b oe For example in the 5 2 mode the period setting sequence fs g Press M 5s the week area will blinking 1 5 Reference on the right Image rT rR U a P1 hr gt min gt setting value gt P2 hr gt min gt setting value gt P3 hr gt min gt setting value gt vies O6 00 gt P6 hr gt min gt setting value The week area will auto change 6 7 and blinking P1 hr gt min gt setting value gt P2 hr gt min gt setting value gt P3 hr gt min gt setting value gt gt P6 hr gt min gt setting value Total setting value is 12 sets lt 5 gt P1 P6 lt 2 gt P1 P6 you will setting 12X3 values If you want skip the setting item you can press M You can use the to back to the previous setting The automatic default mode of the machine factory is 5 2 mode Time specific data see the following table You can modify when you enter the programming interface sezmode tot e Jre m rs re 1 3 es a Tooo omn oao Tresa Tiro faeo 5T Saturday to Sunday Set value 22 C 1 15C For example in the automatic mode when the system time for the Friday 08 20 display will show WEEK 5 or STAGE 2 and the setting temperature value of 15 degrees Advanced function setting Warning System setting is used to set some important parameters of the system that s only for rofessionals Do not
2. Itis set bL is ON in the system menu 2 It is damaged please replace it 9 Large deviation of measurement temperature and the actual temperature 1 The thermostat should be installed at ventilated place It cannot be installed at the place in direct sunshine or nearby the heater 2 Back connection screw is not locked causing terminal serious fever 10 Display 0 degrees When the thermostat of the working environment temperature below the detection 0 degrees that display 0 degrees The above is some of the most common errors if you can t solve please contact the local dealer Dimension in mm Step 1 Separate the Polycarbonate Bezel unit from the LCD screen A Hook B Buckle Step 2 In Laka buckle outside at the same time lift up the movement it is necessary to separate the iron with the movement Step 3 Fixing plate with screws to the wail to ensure that the de energized state product back wiring diagram connected electrical lines Combinations Align the four hooks press down on the movement the iron plate with movement combinations and then fasten the frame
3. make any improper modification The item already been debugged and tested b professionals there is no need to reset Enter the advanced function setting Press the to switch off the thermostat Display will show OFF Press O again it will turn on Please press Key M innext second it will into the advanced function setting You can press MA to switch the system parameters At the same time press the A or V withthe parameters to modify settings Select a set of content If you do not by the A or V the parameters will not modified If you want to save the data you must go through all the functions and exit the system menu The system parameters according to the following order AdJ gt PrG gt LtP gt SEn gt Top gt dt0 gt dt1 gt bL gt Sat gt dEF The thermostat s display type is LCD segment displaying There are some different for the display value and practical value Please refer to the specific figure 1 L O iyi 0 P Ler tH SAE oul te j 3 007 QEF F ig CUE ho ie rr oy SE A BL gEE 33sen in DFF Set the content The default value temperature correction 5 5C It is used to correct the error the measured values of the sensor When you set it the LCD displays the correction value After three seconds the LCD displays the measured value after correction The period time mode 5 2 6 1 7 5 2 Monday to Friday to set the same and Saturday to Sunday t
4. UTRO8b Heating Thermostat User Manual General Heating Thermostat with weekly programming adopts the latest single chip computer control technology thas the high reliability and powerful anti jamming It can realization energy saving and comfortable living environment The application is the electric heating equipment and Water heating ystem of electric heating or actuator control According to the preset temperature the thermostat will automatically start and stop the controlled object valve floor heating the heating wall electric heater etc Multiple time modes 5 2 6 1 7days the heating equipment supports different temperature setting accordingly with 6 time modes daily Users are free to choose manual mode or full automatic mode for different purposes e Using flame resistance material the heating equipment is safe and reliable Its appearance is stylish and its mirror screen would be very easy to clean The clock would continue to run even if power was cut off and it will not affect the period setting value Keypad locking function is designed to prevent the children from misusing Technical parameters Power Supply 85 250VAC 50 60 Hz The maximum switch power 2A 16A Internal sensor measurement range 0 40 C External sensor measurement range 0 99 C Setting range 5 35 C factory settings 25 C Setting range 5 95 C factory settings 50 C Inside sensor NTC B 3380 Extra sen
5. k if the inlet wire is normal If the connection is not right please wired up as the wiring diagram on the back side The thermostat of the working environment temperature is too low please note the thermostat temperature range If the temperature is lower than 5 C the thermostat cannot normally display Power supply box and the motherboard Coupling is not connected correctly please connect correctly Power supply box and the motherboard Coupling is opposite inserted please mind the direction Power supply box and the motherboard Coupling is broken please don t overexert Coupling length is 6cm the installation must be careful If damaged no warranty and replacement 2 Display rupture Display encounters hard objects or sudden force no replacement and warranty 3 Display a black screen If the display surface temperature is too high please note whether there is heater nearby if so please remove 4 Display ERO If internal sensor is abnormal please pay attention to whether the small black dot in temperature sensing window damaged during removal 5 Display ER1 The system is set in the dual temperature control ALL mode or it is not connected with an external sensor or the external sensor is abnormal 6 No pen on LCD Please check whether the iron plate is deformation when installation If it is deformation please correct it 7 No backlight Please check backlight cable is pulled off the panel was removed 8 Backlight always bright 1
6. mperature control ALL Temperature control is based on the internal sensor Temperature measurement and external sensor over temperature protection Adapted to detect the room temperature and is monitored whether the heating element over temperature If the external sensor is over temperature thermostat will shuts down the heater Display three types of temperature When the thermostat work in mode IN and mode ALL The main screen shows air temperature or room temperature when AIR icon will be lit The vice monitor would set temperature every 5 seconds and alternatively display current time When the thermostat works in OUT mode the FLOOR icon will be lit The main screen will display floor temperature or external sensor location temperature When the temperature is in mode ALL press G and W can detect floor temperature or external sensor location and the FLOOR icon will be lit The main screen will automatically display air temperature 5 seconds later after the AIR icon lit System time How to set the system time Keep pressing G for 5 seconds it will enter into the time setting The current revisable object will flash and display Press and choose time you want to revise week hour minute press A or Y to modify the current setting If you need to modify the previous parameters please press M key After the modified minutes you can press to exit the system clock settings Automatic manual switch Press M you ca
7. n choose the manual mode or automatic mode Manual mode System will control temperature under the set value without any change Automatic mode System would control temperature according to the preset temperature values in different time The icon wilt lit which means that the system is running under automatic mode The week and Stage icon would alternately display every 5 seconds 1 7 is systematic reuse When screen shows WEEK 1 7 would display the values of the week When screen shows STAGE 1 6 would display the current values Setting the periods of time modes The thermostat can t quit when you set the periods and it will automatically save data and exit when all setting is finished The periods setting can realize the control of temperature and time under automatic mode Once setting up the values could be saved and reused in the thermostat forever The thermostat can save three kinds of schedules 5 2 6 1 7 in 6 periods One week for a cycle Each data is saved as the start time hours minutes and the temperature values of this period The end time of the period would be saved as the start time of next period You can also shut down a certain period according to your needs Press the M for 5 seconds you will enter into the period setting interface The number is blinking in WEEK area it means the mode of your set 5 2 or 6 1 or 7 You can press button MA to select the object you want to modify the period start time hours
8. o set the same 6 1 Monday to Saturday to set the same Sunday is independent 7 Monday to Sunday is same setting value On Enable _ _ OFF Disable Low temperature protection what is suitable for the water system To prevent the pipe at low temperature was freezing PrG LtP IN Built in OUT External ALL Dual temperature control IN internal control room sensor Out external control floor sensor ALL double temperature double control the internal room temperature sensor external sensor overheating protecting 40 80 C 50 C The sensor is set to ALL the temperature limit external sensor value Internal sensor hysteresis 0 5 4 C TE Built in temperature sensor hysteresis External sensor hysteresis 0 5 5 C 3T External temperature sensor hysteresis On Always on OFF OFF Auto turn off after 5sec i Backlight lighting mode can be set according to personal preference Sensor or temperature control mode Sen External temperature sensor limit tOP dto dt1 Backlighting status bL gnting OFF off status at every time Status at re power Sat On the same as previous Used to control the power state of the boot deF Restore factory settings To restore the default settings The error and solution of common system 1 No display Power supply system is having problems or power is supplied incorrectly please chec
9. sor NTC B 3380 10k 25 degrees Celsius 10k 25degrees Celsius length 3 meters optional Display type LCD Display area 60 x 32 mm Display resolution 0 1 C Setting Unit 0 5 C step i Manualmode Auto model Air temperture Operation Guide Heating Se a Floor temperture On and off Measured values j a Press you can be turn on or turn 4 Stage E a z _ Seconds _ off the thermostat power Week H ale ee s i A When thermostat is OFF it display the Valefor 345080 jes J33 Settings values air temperature and OFF see the following Week peg o m 3 ae olack e oc 397 U HOO Oy E Alba er g FE Power On Off Lock Press key M for 2 seconds at the same time A the keypad is locked LCD will show In the locked status press the key m for2 seconds it will be unlocked Temperature control mode According to the sensor setting of thermostat there are three different control modes enter the advance function to set Internal control IN Only enable internal sensor to temperature measurement that the temperature control basis from the internal temperature sensor It is suitable for the detection of air temperature or the room temperature External control OUT Only enable external sensor to temperature measurement that the temperature control basis from the external sensor It is suitable for the detection of the heating body temperature Dual te