1. Switch Description Switch function number 1 Device Mode On STU C Master CO mode Off STU R Slave CPE mode 2 Extended Rates On Extended bit rates Off ITU T standard bit rates 3 Reserve Reserved for future use 4 Test mode TM1 Both off no test mode normal function 5 Test mode TM2 TM1 on TM2 off PSD test TM1 off TM2 on idle Silent State Both on Loopback Please note that you have to remove protective tab on top of DIP switch before first use 3 7 Select bit rate The rotary switch is used for selection of the bit rates The selection will be sampled once after reset Please use also the reset button after changing the bit rate The target SNR margin is set to 6 dB Switch Extended Rates Lineprobing Bitrate PAM position DIP switch 2 kbit s 0 default Off Enabled 192 5686 Auto 1 Off Disabled 192 16 2 Off Disabled 384 16 3 Off Disabled 512 16 4 Off Disabled 768 16 5 Off Disabled 1536 16 6 Off Disabled 2048 16 7 Off Disabled 2304 32 8 Off Disabled 3072 32 9 Off Disabled 5696 32 0 On Enabled 64 15296 Auto 1 On Disabled 64 4 2 On Disabled 192 4 3 On Disabled 192 8 4 On Disabled 2496 4 5 On Disabled 5056 8 6 On Disabled 7616 16 7 On Disabled 10176 32 8 On Disabled 12736 64 9 On Disabled 15296 128 Revision 1 2 1 2015 04 20 7 9 shdsI teleconnect de SOCRATES EVB Quick Start Guide Teleconnect
2. 3 8 LEDs 3 8 1 Power green Off SOCRATES EVB not powered up On Power supply ok the board is active 3 8 2 SHDSL state green Off SHDSL not active Slow blinking SHDSL is ready SOCRATES is initialized Fast blinking SHDSL training phase On SHDSL connection is established 3 8 3 Ethernet Link Activity green Off no Ethernet connection On Ethernet link detected Blinking Ethernet connection with data traffic 3 8 4 Error Amber Off The board is working without any failure On blinking An error has occurred Revision 1 2 1 2015 04 20 8 9 shdsI teleconnect de SOCRATES EVB Quick Start Guide Teleconnect 4 Start up guide The following description provides an easy way to establish a data connection using SHDSL You need at least one SOCRATES EVB and one any other standard conform SHDSL modem However the easiest way to make a SHDSL connection is to use two SOCRATES EVB 4 1 Realize the Long Reach Ethernet Connectivity Check your existing application infotainment systems video surveillance vending machines traffic control emergency communication sense and control for an existing Ethernet interface Connect Ethernet interface to SOCRATES EVB Connect 5 V power supply to the Micro USB connector Connect SHDSL lines Select bit rate and operation mode e g master mode STU C or slave mode STU R 4 2 Start up with two boards 1 2 3 4 Verify default settings all DIP switches o
3. The picture shows only the main components There are a lot of further components besides those depicted Please also look at SOCRATES EVB bill of material 2 3 Bourns For more information about Bourns Inc please look at http www bourns com Bourns is a leading supplier of SHDSL protection solutions 2 4 GEYER Further information about GEYER ELECTRONIC ek are given at http www geyer electronic com The Crystal 40 96MHz is a special development for the SOCRATES chip Revision 1 2 1 2015 04 20 5 9 shdsI teleconnect de SOCRATES EVB Quick Start Guide Teleconnect 3 Functional description The following picture shows the control and operating elements The SOCRATES EVB is designed to work autonomously without using external software Just plug and play Amber LED Green LED SHDSL state Micro USB Error detected Connection established Training Idle Power and UART emulation Select bit rate Select mode Green LED Ethernet Link Activity JTAG Connection to AVR Debugger Connection to Programmer Ethernet Erase Button ERIERDEE Green LED Connector Power Alternative Connection to Power 5 0V SHDSL Line Reset Button SHDSL Connector f Se Jp e i NE Ki Alternative UART 3 1 SHDSL Connector The unshielded RJ45 connector is used for connecting the SOCRATES EVB to one SHDSL line according to ITU T G 991 2 using Pin 4 and 5 The other pins are not connected A stand
4. Teleconnect Verbindungen in die Zukunft SOCRATES EVB Quick Start Guide Revision 1 2 1 2015 04 20 Teleconnect GmbH Am Lehmberg 54 2015 Teleconnect GmbH 01157 Dresden Germany SOCRATES EVB Quick Start Guide Teleconnect Revision History Revision 1 2 1 2015 04 20 Revision Date Comment 1 0 0 7 Jan 15 Internal release 1 0 1 21 Jan 15 Reviewed document 1 2 1 20 Apr 15 Release for software revision V1 2 Revision 1 2 1 2015 04 20 2 9 shdsI teleconnect de SOCRATES EVB Quick Start Guide Teleconnect Table of Contents T MOL Ur Of ee ee 4 2 Component OVENIEW een e EEEEEEREEESA dE dertEEeeEeR 5 21 SHDSL chip SOCRATES 1e PEF21B2BE n una a 5 22 W rth Elektronik Eege 5 29 seen 5 IE YE EE 5 3 Functional description et ee 6 3 1 SHDSL ln EN 6 3 2 Ethernet Connector EE 6 C7 SE WE E 6 3 4 Reset Button see res 6 35 Blase BUO EEN 6 3 6 Select e 7 37 Slet bitrate een nee Bin iii N N ee ere 7 Be EE 8 3 8 1 Power green eier ee ee 8 382 ele Ee E EE 8 3 8 3 Ethernet Link Activity green ENNEN 8 3824 Error AMDE zus keinen 8 4 Starup UN ern 9 4 1 Realize the Long Reach Ethernet Connectivity 22244444nnnnnnnnnnnnnnnnnnnnnnnnnnn nenn 9 42 Start up with two boards EE 9 Revision 1 2 1 2015 04 20 3 9 shdsl teleconnect de SOCRATES EVB Quick Start Guide Teleconnect 1 Introduction The new SOCRATES EVB 1 0 Reference Design targeting industrial designs enables new customers to take advantage of Lantiq SHDSL
5. ard Ethernet cable is also usable Beside the RJ45 connector SOCRATES EVB provides the possibility to use a pin header 3 2 Ethernet Connector The shielded RJ45 is a standard Ethernet interface It is compatible to 10BASE T and 100BASE TX Ethernet according to IEEE 802 3 Besides the RJ45 connector SOCRATES EVB provides the possibility to use a pin header 3 3 Micro USB The main function of the Micro USB Connector is the power supply Connect to USB plug in power supply 5 V or any self powered USB host interface The Micro USB Connector can also be used as a management interface using UART emulation 3 4 Reset Button Pressing this button triggers hardware reset of processor and SHDSL interface 3 5 Erase Button There are two functions Pressing the Erase Buttton during reset Reset button is also pressed will be cleared the whole flash memory This is necessary to reload a new Firmware version via processors SAM BA interface During runtime additional information about software and line state will be printed to the serial interface UART if the button is pressed Revision 1 2 1 2015 04 20 6 9 shdsI teleconnect de SOCRATES EVB Quick Start Guide Teleconnect 3 6 Select Mode The DIP switch is used for selection of operation mode The selection will be sampled once after reset Please use also the reset button after changing the operation mode There are 5 DIP switches available The following table describes the functions
6. ff rotary switch on 0 Switch on Device Mode DIP switch 1 for Master STU C at one board Connect both SHDSL connectors together You can use a standard Ethernet patch cable Power up both boards E g connect the micro USB plug to PC e The power LED Error LED and the SHDSL LED go on e After some seconds the amber Error LED goes off The SHDSL LED starts blinking slowly e The SHDSL LED blinks fast during SHDSL Training e The SHDSL LED is on if the SHDSL connection is established Disconnect the Ethernet cable from your computer plug it into the Ethernet connector of the first board Connect the wall outlet to the Ethernet connector of the second board e The Ethernet LED is on for established Ethernet connection e The Ethernet LED starts blinking for Ethernet traffic Ready You are using SHDSL for your data connection Revision 1 2 1 2015 04 20 9 9 shdsI teleconnect de
7. for long reach broadband connectivity It s the first ever ready to copy reference design developed for the Lantiq SOCRATES Chip The SHDSL Ethernet Bridge Modem was developed by Teleconnect and measures only about 9x5cm and is available for online purchase through the W rth Midcom Website http www we online com socratesdemo Teleconnect offers dedicated support for board and software customizations With this for the first time ever even smaller companies without DSL expertise can include SHDSL and Long Reach Ethernet connectivity into their designs SHDSLs unique rate reach performance makes it the product of choice in an ever more diversified field of applications ranging from business broadband access to enterprise networks and industrial communications Known as long haul Ethernet SHDSL was included in the Ethernet standard IEEE 802 3 2008 where it is named 2BASE TL Standard Ethernet has a maximum reach of 100 m SHDSL has a reach beyond 15 kilometres Using SHDSL makes it possible to Transmit Ethernet over only one unshielded twisted wire pair or over any other cable SHDSL Long reach Ethernet Ethemmet Intranet Internet N Ethernet SOCRATES EVB SOCRATES EVB Industrial and enterprise application Revision 1 2 1 2015 04 20 4 9 shdsI teleconnect de SOCRATES EVB Quick Start Guide Teleconnect 2 Component Overview The following picture shows the top side of SOCRATES EVB The most important compo nents a
8. re described in this chapter Rotary Switch DIP Switch LED Crystal 12 MHz WE 428542320810 WE 416131160805 WE 150080VS75000 GEYER 12 88673 el Micro USB Type B Wes WE 629105136821 Ethernet PHY Lantiq XWAY PHY11G PEF7072 D ba PN Microcontroller m Gi a EI E A x ATSAM4S LAN Transformer i WE 749020010A Power Supply 5V to 1 0V UE Modular Connector el Switch WE 615008143521 3 S WE 430181038816 Hila Power Supply SHDSL Transformer 5V to 3 3V WE 750510578 Power Supply 5V to 1 5V Modular Connector SHDSL WE 615008143721 Lantiq Socrates 1E PEF21628E TVS Diode Array Bourns Crystal 40 96 MHz Crystal 25 MHz CD143A SR3 3 bottom side GEYER 12 99999 GEYER 12 88751 Please download the latest version of the bill of material It is recommended to use the listed components 2 1 SHDSL chip SOCRATES 1e PEF21628E SOCRATES is the world s leading SHDSL solution For more information about Lantiq Semiconductor see http www lantig com and about SHDSL see https www lantig com shdsl Please register at http www lantig com for data sheets It is also possible to use the pin compatible 2 or 4 channel chips PEF22628E and PEF24628E However SOCRATES EVB provides only one usable channel 2 2 W rth Elektronik WE For more information about W rth Elektronik GmbH amp Co KG please look at http www we online com The largest number of components used at SOCRATES EVB comes from WE

Download Pdf Manuals

image

Related Search

Related Contents

DIRIS A40/A41 2 Outputs kWh - kvarh - KVAh  Copyright © 2010 ZTE CORPORATION. Todos os Direitos  Web Client - smart systems & solutions  Hydra User Guide 1_5    User manual-EX-17-19LBE  Star Trac E-TR User's Manual  MK.100.I - Renascer Madeiras  Guía del Usuario del Monitor Táctil  指導検査基準(特定福祉用具販売事業)  