1. This manual contains important safety instructions Please follow up all instructions carefully during instal lation Read this manual thoroughly before attempting to install or operate CAUTION To prevent the risk of fire or electric shock please install the unit in a temperature and humidity controlled indoor area which is free of conductive contaminants CAUTION Risk of electric shock Do not remove the cover No user serviceable parts inside Refer servicing to qualified service personnel CAUTION Risk of electric shock Hazardous live parts inside this UPS can be energized from the battery sup ply even when the input AC power is disconnected CAUTION Risk of electric shock The battery circuit is not isolated from AC input hazardous voltage may exist between battery terminals and ground Please test it before touching 2010 Elektro Automatik GmbH amp Co KG About the device 1 Introduction Thank you for selecting this Uninterruptible Power Sup ply UPS It provides you with a perfect protection for connected equipment The manual is a guide to install and use the UPS It includes important safety instruc tions for operation and correct installation of the UPS If you have any problems with the UPS please refer to this manual before calling customer service 2 Function overview Guard LCD Series UPS has the following functions e The LCD panel enables the easy display of infor mation e Precise vo
2. Netzausfall schaltet die USV automatisch in den Batteriebetrieb auch Backup Modus genannt Dann werden die angeschlossenen Verbraucher ber einen Spannungswandler von den Batterien versorgt und die USV signalisiert dies mit einem Alarmton Anzeige Batteriebetrieb 2010 Elektro Automatik GmbH amp Co KG Irrtumer und nderungen vorbehalten DE Nach Wiederkehr der Netzversorgung schaltet die USV automatisch in den Normalbetrieb um der Alarm ver stummt und die Batterien werden wieder aufgeladen Dazu ben tigt die USV je nach Dauer des vorange gangenen Netzausfalls unterschiedlich lange Sollte der Netzausfall l nger dauern als die berbr k kungszeit des Ger tes f r die jeweilige Belastung angibt entladen sich die Batterien soweit da sich die USV abschaltet In diesem Moment werden die ange schlossenen Verbraucher auch sofort abgeschaltet Um einen eventuellen Datenverlust am PC vorzu beugen kann die USV von dem PC den sie versorgt berwacht werden Siehe Abschnitt 7 3 7 3 berwachung der USV ber USB am PC Um bei einem Netzausfall und eventueller Selbstab schaltung der USV wegen berlast bzw aufgebrauch ter berbr ckungszeit einen Datenverlust am PC zu verhindern kann die USV ber das mitgelieferte Datenkabel und die beiliegende Software berwacht werden und ggf den PC herunterfahren Verbinden Sie dazu einfach die USV und den PC mittels des mitgelieferten Kabels installieren und starten S
3. with an acoustic alarm Display in battery operation 2010 Elektro Automatik GmbH amp Co KG EN After return of the mains supply the UPS will switch automatically to normal operation the batteries are charged again and the acoustic alarm vanishes The recharge time varies depending on the duration of the former mains failure Means the level the batteries were discharged to In case the mains failure lasts for a longer time the batteries will discharge and the UPS will switch off before the deep discharge level is reached In this very moment the connected loads are also switched off immediately In order to prevent this and an eventual data loss atthe PC the UPS can be monitored by the PC it is connected to See section 7 3 7 3 Monitoring the UPS with USB and a PC In order to prevent data loss because of a mains failure or automatic self shutdown because of overload over heating of the UPS the UPS can be monitored by a PC and an appropriate software which can shut down the PC safely before any critical level has been reached Simply connect the UPS and the PC serial port in stall start and configure the included software to your demands The data cable can be extended by a extension cable A maximum total length of 5m without an USB hub shall not be exceeded 8 Maintenance The internal batteries are sealed maintenance free ty pes which do not require regular maintenance After the nominal lif
4. Batterie charging level Load bar graph Switch 7 Terminals rear 1 Input fused 2 Output outputs IEC Schuko 3 USB communication port 4 Telefon Modem Fax protection 5 Input fuse 11 y A 2010 Elektro Automatik GmbH amp Co KG About the device 7 Handling and operation The button on the front is used to switch the device on or off at mains presence or at mains failure cold start Press the button shortly and firmly until you can hear a beep sound After a short lead time the UPS will be ready to work During operation the display constantly indicates all necessary values at a glance Errors acoustically indi cated There are no further operating elements Display in offline operation 7 1 Normal operation Normal operation at an UPS means the presence of mains voltage where the load s are supplied by the UPS via an internal transformer which is standard at models with Line Interactive technology The output voltage is stabilised in a certain range by a so called boost amp buck converter During operation of the UPS the display indicates the measured input voltage as well as load level battery level and output voltage 7 2 Battery operation backup At a mains failure mains loss or undervoltage the UPS will automatically switch to battery operation also called backup mode Then the consumer s are supplied from the batteries via a voltage converter The UPS signalises this
5. D U M Aw p e mba e uan SZ Line Interactive UPS Sa gt M Guard LCD 2 Series 600VA 2000VA GLCD2 600 GLCD2 650 GLCD2 1000 GLCD2 1500 GLCD2 2000 36 700 214 36 700 215 36 700 216 36 700 217 36 700 218 Allgemeines Impressum Bedienungsanleitung f r Guard LCD 2 USV Serie Elektro Automatik GmbH amp Co KG Helmholtzstrasse 31 33 41747 Viersen Germany Telefon 49 02162 37850 Fax 49 02162 16230 Web www elektroautomatik de Mail ea1974 elektroautomatik de 2010 Elektro Automatik Nachdruck Vervielf ltigung oder auszugsweise zweckentfremdete Verwendung dieser Bedienungsan leitung sind verboten und k nnen bei Nichtbeachtung rechtliche Schritte nach sich ziehen Stand April 2010 DE Wichtige Hinweise Diese Anleitung enth lt wichtige Sicherheitshinweise Diese sind bei Verwendung und Installation des Ger tes unbedingt zu beachten Lesen Sie diese Anleitung daher sorgf ltig durch ehe Sie das Ger t installieren und in Betrieb nehmen VORSICHT Um die Gefahr eines elektrischen Schla ges oder eines Brandes zu vermeiden installieren Sie das Ger t in einer trockenen temperaturgeregelten Umgebung Diese sollte m glichst frei von Stoffen sein die bei Betrieb des Ger tes einen Brand einen elektrischen Schlag gegen den Anwender oder andere Sch den verursachen k nnen VORSICHT Gefahr des elektrischen Schlages Nicht die Abdecku
6. as Display erleuchtet wird 2 Die Batteriespannung k nnte aufgrund langer La gerungszeit oder Nichtbetriebes des Ger tes zu niedrig sein Lassen Sie die USV eine l ngere Zeit ohne Last am Netz damit die Batterien geladen werden k nnen Wenn Sie die USV danach immer noch nicht einschal ten k nnen kontaktieren Sie Ihren H ndler 10 Blockdiagramm POWER INPUT RECTIFIER INPUT VOLTAGE CHECKING BATTERY CHARGER JA DE Wenn die berbr ckungszeit zu kurz ist 1 berlast Trennen Sie die berlast verursachenden Ger te vorl ufig von der USV und pr fen Sie ob die ber br ckungszeit dann wieder normal ist Stellen Sie auch sicher da die Gesamtlast die Nennlast der USV nicht berschreitet 2 Die Batterien sind nicht voll geladen Lassen Sie die USV f r l ngere Zeit ohne Last am Netz damit die Batterien vollst ndig geladen werden k nnen 3 Die Batterien sind nicht mehr leistungsf hig genug Schicken Sie die USV zu Ihrem H ndler damit die Batterien ausgetauscht werden LOAD DC AC INVERT BATTERIES 2010 Elektro Automatik GmbH amp Co KG Irrt mer und nderungen vorbehalten Uber das Ger t DE 11 Technische Daten Ausgangsdaen SSS 230V 10 rechteckf rmig Freguenz 50 60Hz 1 Scheinleistung 600VA 650 VA 1000VA 1500VA 2000VA Wirkleistung 360W 390W 600W 900W 1200W Leistungsfaktor cosp 0 6 Ssanntnessodluh AVR automatische Erhohung von 15 bei Eingan
7. bieten einen zus tzlichen Schutz gegen ber berspannungen von au en z B durch einen Blitz Nicht kompatibel mit ISDN 3 Stecken Sie das Netzkabel der USV ein Achtung Laden Sie die USV mindestens 8h an einer Netzsteckdose auf bevor sie zum ersten Mal benutzt wird 4 Schalten Sie die USV ein indem Sie den Knopf auf der Vorderseite ca drei Sekunden lang bet tigen und lassen Sie ihn los wenn die USV einen Piepton erzeugt Die Anzeige sollte daraufhin aufleuchten und die USV den Betrieb starten Im Fall da das Ger t bei einem Netzausfall gestartet wird Kaltstart wird sofort ein Alarmsignal ausgegeben Hinweise Die Batterien der USV werden wenn Netzspannung vorhanden ist st ndig geladen und berwacht Bei hoher Belastung des Ger tes im Normalbetrieb kann das Laden der Batterien l nger dauern als bei gerin gerer Last Im Batteriebetrieb Netzausfall Unterspannung schaltet sich die USV ab wenn die Batterien nahezu entladen sind damit keine Tiefentladung stattfindet Die berbr ckungszeit gibt die Zeit bis zur Abschaltung an Bitte beachten Sie die Nennleistungsangaben in den technischen Daten wenn Sie einen PC an die USV anschlie en Dessen Nennleistung darf die der USV nicht berschreiten sonst schaltet sich die USV wegen berhitzung Normalbetrieb oder vorzeitiger Batterientladung Netzausfall ab KA 3 Uber das Ger t DE 5 Bedienelemente Vorderseite Ausgangsspannung m I A
8. e not been charged completely Connect the UPS to mains for fully charging the bat teries 3 The performance of the batteries may not be good due to long time use Send the UPS to your supplier for replacing the bat teries LOAD DC AC INVERT BATTERIES 2010 Elektro Automatik GmbH amp Co KG About the device EN 11 Technical specifications Inputspecs GLOD2600AP cLcozoso AP GLCD2 1000 AP GLCD2 1500 AP GLCD2 2000 AP Input voltage 175 300V c owpsee OOS 230V c 10 rectangular Power factor cosp 0 6 AVR automatic increase of 15 at input voltage of 10 26 of nominal AVR automatic decrease of 15 at input voltage of 10 22 of nominal Battery A M 6 hours to 90 capacity Backup time 50 Load 75 Load Protection N Short circuit overload deep discharge spike suppression modem network Bandaras AAA Environment 0 90 non condensing Communication Voltage regulation 2010 Elektro Automatik GmbH amp Co KG y A Elektro Automatik EA Elektro Automatik GmbH Co KG Entwicklung Produktion Vertrieb Helmholtzstra e 31 33 41747 Viersen Telefon 02162 37 85 0 Telefax 02162 16 230 ea1974 elektroautomatik de www elektroautomatik de
9. e time or at premature aging and noticeable capacity drop backup time too short they should be replaced This is only done by trained personnel which is instructed about the replacement procedure If the UPS is not used for a longer time we strongly recommend charging it completely every 2 3 months to maintain battery capacity and life time 9 Troubleshooting If the UPS is having an abnormal condition 1 First disconnect the input power line and output connections and then check whether all connections have been made properly 2 Check the fuse If the fuse is blown then replace it with one having the same current and voltage rating 3 Remake all connections and try to switch the UPS on w gt m About the device If you can t switch on the UPS 1 Make sure you pressing the button firmly and release the button when the UPS creates a beep sound 2 The voltage of the batteries might be too low due to a long time storage or non operation Let the UPS stay on mains and without load to recharge the batteries If you still can t switch on the UPS then contact your supplier 10 Block diagram POWER INPUT RECTIFIER DC SLAVE POWER INPUT VOLTAGE CHECKING BATTERY CHARGER EN If the UPS is having a short backup time 1 Overload condition Unplug the overload causing computers or other equip ment Make sure the total load capacity is not exceeding the UPS capacity 2 The batteries hav
10. ement e Akustische Alarme e Energiesparmodus automatische Abschaltung im Leerlauf bei Batteriebetrieb e Zuverl ssiger Schutz f r Computer und andere elektronische Ausr stung e Benutzerfreundliche Bedienung e Uberwachungssoftware 3 Verwendung Nur in geschlossenen R umen verwenden 4 Nicht berm iger Hitze oder Feuchtigkeit ausset zen F r Bel ftung ausreichend Platz um das Ger t herum freilassen Nicht fur andere Verbraucher als Computer oder hnliche Ger te verwenden Keine Haushaltsger te anschlie en 2010 Elektro Automatik GmbH amp Co KG Irrtumer und nderungen vorbehalten 4 Installation und Inbetriebnahme 1 Untersuchen Sie die USV nach dem Erhalt Bei einem Schaden benachrichtigen Sie den Zulieferer und den H ndler Die Verpackung ist wiederverwertbar und sollte entweder aufbewahrt oder umweltgerecht entsorgt werden Vorsicht Keine Laserdrucker an die USV anschlie en Diese k nnen hohe Spitzenstr me erzeugen die die Ausgangsspannung der USV eventuell zusammen brechen lassen wodurch sich das Ger t wegen eines Unterspannungsfehlers abschalten kann 2 Verbinden Sie den Computer oder das anzuschlie Bende Ger t mit der USV und stellen Sie sicher da der Computer bzw das angeschlossene Ger t ausge schaltet ist Auf der R ckseite des Ger tes befinden sich zwei Buchsen wo normale Telefonger te wie Fax Modem oder Analogtelefone angeschlossen wer den k nnen Diese
11. gsspg 10 26 von Nennwert p gsreg 9 AVR automatische Absenkung von 15 bei Eingangsspg 10 22 von Nennwert Umschaltzeit 2 6ms Anzeige Normalmodus Batteriestatus Lastpegel Ein Ausgangsspannung Batterie Batterietyp Geschlossen wartungsfrei Blei S ure Aufladezeit 6 Stunden auf 90 Kapazit t Batterieanzahl 1 Stk 12V 4 5Ah 1 Stk 12V 7 2Ah 2 Stk 12V 7 2Ah 2 Stk 12V 9Ah berbr ckungszeit 50 Last 11min 75 Last 4min Diverse Kurzschlu berlast Tiefentladung Netzfilter Modem amp Netzwerk Sicherheit EN 62040 1 EMV EN 62040 2 Schutzklasse IP20 Umgebung Betriebstemperatur 0 40 C Feuchtigkeit 0 90 nicht kondensierend Ger uschentwicklung lt 40dBA bei 1m Kommunikation Port USB Anschlu Typ B Abmessungen BxHxT 100x142x287mm 146x160x350 146x205x397mm Lastanschl sse 1x IEC 1x Schuko 2x IEC 2x Schuko 2010 Elektro Automatik GmbH amp Co KG E Irrtumer und Anderungen vorbehalten A About amp Copyright User instruction manual for Guard LCD 2 UPS series Elektro Automatik GmbH amp Co KG Helmholtzstrasse 31 33 41747 Viersen Germany Phone 49 02162 37850 Fax 49 02162 16230 Web www elektroautomatik de Mail ea1974 elektroautomatik de 2010 Elektro Automatik Reprint duplication or partly wrong use of this user instruction manual are prohibited and might be followed by legal consequences Date April 2010 EN Important notes
12. ie die Software und konfigurieren Sie diese entsprechend ihren Bed rfnissen Das Datenkabel kann mit einem passenden Ver langerungskabel verl ngert werden Eine maximale L nge von 5m ohne USB Hub soll nicht berschritten werden 8 Wartung Die internen Batterien xsind geschlossene wartungs freie Batterien die nicht regelm ig gewartet werden m ssen Nach der blichen Lebensdauer oder bei vorzeitiger Alterung und merklichem Leistungsabfall berbr ckungszeit zu kurz sollten sie getauscht werden Dies ist nur von einer autorisierten Person vorzunehmen die ber die Vorgehensweise unter richtet ist Falls die USV l ngere Zeit nicht benutzt werden sollte wird eine vollst ndige Aufladung der Batterien alle 2 3 Monate empfohlen um die Lebensdauer der Batterien zu erhalten 9 Fehlerbehandlung Wenn sich die USV unnormal verh lt 1 Entfernen Sie zuerst das Netzeingangskabel und die Verbindungen am Ausgang und pr fen Sie dann ob alle Verbindungen in Ordnung sind 2 Pr fen Sie die Sicherung in der Netzeingangsbuch se Wenn sie defekt sein sollte so ersetzen Sie sie mit einer gleichen Typs gleiche Spannung Gr e und Strom YE 5 Uber das Ger t 3 Verbinden Sie alle Kabel wieder und versuchen Sie die USV wie gehabt einzuschalten Wenn Sie die USV nicht einschalten k nnen 1 Achten Sie darauf den Knopf richtig bis zum An schlag zu bet tigen bis die USV einen Signalton von sich gibt und d
13. like they re caused by lightning for example Works only for standard pho ne line equipment not with ISDN 3 Connect the UPS to the mains socket Attention Before using the UPS charge it for at least 8 hours on a wall outlet 4 Switch on the UPS by pressing the button for ap proximately three seconds and then release the button when the UPS creates a beep The display should light up and the UPS starts to work In case the device is started during a mains failure cold start an acoustic alarm signal is emitted immediately Notices The batteries of the UPS are constantly charged and supervised as long there is normal operation at mains presence The charging time to full level might be ex tended by a high load compared to low load In backup operation mains failure undervoltage the UPS will switch itself off when the batteries are discharged down to a certain level in order to prevent deep discharge The given backup time is the time the UPS will work before it switches off Always observe the nominal power given in the technical specificati ons when connecting consumers such as PCs The nominal power of the PC must not exceed the one of the UPS or else the device might switch off because of overheating in normal operation or untimely battery discharge backup operation KA 10 About the device EN 6 Operating elements front Output voltage m am Operation mode an Al N Input voltage
14. ltage stabiliser with sensitive automatic voltage regulation AVR e Frequency auto sensing e Short circuit overload surge amp high low voltage protections e Cold start amp automatic recharge functions e Intelligent battery management system e Audible alarms e Energy saving mode automatic shutdown when there is no load during battery operation e Reliable protection for computers and electrical equipment e User friendly operation e Monitoring software 3 Placement Only use in closed rooms Do not expose to extreme heat or humidity Always take care for sufficient room around the de vice for a proper ventilation Never connect other loads than computers or similiar devices except laser printers to the UPS Do not use for household appliances 2010 Elektro Automatik GmbH amp Co KG 4 Installation amp startup 1 Inspect the UPS upon receipt Notify the carrier and dealer if there is damage The package is recyclable save it for reuse or dispose it properly Caution Do not connect a laser printer to the UPS output Laser printers can draw very high surge currents that may cause the UPS output voltage to drop and to start an undervoltage shutdown 2 Connect the computer or fax machine other equip ment to the UPS and make sure that the computer is turned off There are also modem telephone fax protection sockets on the rear which can protect your external devices from high voltages
15. ng entfernen Im Inneren befinden sich keine f r den Anwender relevanten Teile berlassen Sie Wartung und Reparatur qualifiziertem Personal VORSICHT Gefahr des elektrischen Schlages Ge f hrliche spannungsf hrende Teile im Inneren des Ger tes k nnen von der Batterie versorgt auch dann unter Spannung stehen wenn die Netzspannung ab getrennt wurde VORSICHT Gefahr des elektrischen Schlages Der Batteriekreis ist nicht vom AC Eingang isoliert Ber h rungsgef hrliche Spannung kann am Netzeingang an liegen Nicht ohne Vorsichtsma nahmen ber hren 2010 Elektro Automatik GmbH amp Co KG Irrt mer und nderungen vorbehalten Uber das Ger t 1 Einleitung Danke da Sie sich f r diese Unterbrechungsfreie Stromversorgung USV entschieden haben Sie bietet Ihnen einen zuverl ssigen Schutz Ihrer angeschlosse nen Verbraucher Diese Anleitung beschreibt Installa tion und Benutzung der USV Bei Problemen mit dem Ger t schauen Sie bitte zuerst in die Anleitung bevor Sie den Kundendienst verst ndigen 2 bersicht der Funktionen Die Guard LCD USV bietet folgende Eigenschaften e Eine LCD Anzeige die alle wichtigen Information ber das Ger t auf einen Blick zeigt e Pr zise Spannungsstabilisierung mit automatischer Spannungsregelung AVR e Automatische Frequenzerkennung e Kurzschlu Uberlast Uberspannung 8 Unter spannungsschutzmechanismen Kaltstartfunktion e Intelligentes Batteriemanag
16. nzeige Betriebsart m IN Gemessene Eingangsspannung Batterie Ladezustand Belastung Balkenanzeige Ein Ausschaltknopf 6 Anschl sse R ckseite 1 Eingang abgesichert 2 Ausgang Ausg nge IEC Schuko 3 USB Kommunikationsport 4 Telefon Modem Fax Schutz 5 Netzsicherung A 2010 Elektro Automatik GmbH amp Co KG A Irrtumer und Anderungen vorbehalten Uber das Ger t 7 Bedienung und Betrieb Der Knopf an der Vorderseite dient zum Ein und Aus schalten des Ger tes bei vorhandener Netzspannung als auch bei Netzausfall Kaltstart Dazu ist der Knopf kurz zu dr cken bis ein Signalton zu h ren ist Nach einer kurzen Anlaufzeit ist das Ger t betriebsbereit Die Anzeige zeigt w hrend des Betriebes alle wichti gen Wert bersichtlich an Eventuelle Fehler werden akustisch gemeldet Weitere Bedienelemente sind nicht vorhanden Anzeige im ausgeschalteten Zustand 7 1 Normalbetrieb Normalbetrieb bei einer USV bedeutet da Netzspan nung vorhanden ist und die Last en ber die USV und bei Line Interactive Technologie blich einen internen Transformator versorgt werden wobei die Ausgangsspannung ber einen sogenannten Aufwarts Abw rts Wandler innerhalb eines gewissen Bereiches stabil gehalten wird W hrend des Betriebes zeigt die LCD Anzeige die gemessene Eingangsspannung Belastung Batteri eladezustand und Ausgangsspannung an 7 2 Batteriebetrieb Backup Bei einem