Home
User Manual - center
Contents
1. Ethemet Modbus TCP Serial Modbus RTU Serial LS485 ZS ien EK EI ez e e e e e e A a Veh T _ Drive View 3 Installation 3 1 Prepare for installation Copy the installation program of Drive View 7 to the system 1 Folder DV7_ Setup Copy the installation folder DV7_ Setup to the system 2 File It consists of 5 files 3 2 Install 1 Execute Setup exe 2 Drive View 7 Setup Wizard screen will appear ie Drive View 7 Welcome to the Drive View 7 Setup Wizard The installer will guide you through the steps required to install Drive View 7 on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law 3 Click the Next button 4 Screen to Select Installation Folder will appear GG Drive View 7 Select Installation Folder The installer will install Drive View 7 to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder C Program FilestLSlSw Drive View Pr Browse Disk Cost Install Drive View 7 for yourself or for anyone who uses this computer Everyone Just me Drive View 7 LS industrial Systems 5
2. 8 1 2 13 Save As Function to save the already saved file under other name Same with the function to save Scope File 8 1 2 14 Save Scope Screen Function to save the scope screen Graph Monitoring Menu Select File gt Save Scope File 1 Meta File The current screen is saved in a form of meta file 2 JPEG File The current screen is saved in a form of JPEG file 3 Bitmap File The current screen is saved in a form of bitmap file 8 1 2 15 Copy to Clipboard The current monitoring screen is copied to the clipboard Graph Monitoring Menu Select File gt Copy to Clipboard Copy the monitoring screen to the program you are currently using after copying it to the clipboard 8 1 2 16 Print Scope Screen Graph Monitoring Menu Select File gt Print Scope Screen The current screen is printed 8 1 2 17 Graph Screen This menu becomes active when monitoring stops There are regular mode and zoom mode In the regular mode the marker becomes active In the zoom mode the graph becomes either zoom in or out Marker As a vertical line displayed in the graph when monitoring stops the user can use it when inquiring the values at a certain time by moving it arbitrarily st Drive View 7 Te 8 1 3 Description on Functions 58 Recording It begins flashing when recording starts during monitoring With this motion the user can identify whether recording is now in progress or not Trigger It
3. DRV 4 15 Torque Boost Manual DRV 4 16 Fwd Boost 2 0 Result DRV 6 Cmd Source FieldBus Fx Rx 1 El fa ORV 7 Freq Ref Src FieldBus Keypad 1 fa BAS 12 Rated Slip 90 40 FS BAS 13 Rated Curr 3 4 3 6 BAS 14 Noload Curr 17 16 ES FS BAS 16 Efficiency 74 72 fa BAS 23 Ls 1744 1544 ES ADV 75 RegenAvd Level 350 700 F3 CON 11 Hold Time 0 00 1 00 CON 29 S Est P Gain 1 450 300 ES fs IN 5 V1 Monitor V 0 08 0 00 ES IN 20 11 MonitorimaA 0 16 0 00 ES IN 35 V2 Monitor V 10 00 0 00 OUT 41 DO Status b000001 b000000 ES pa COM 1 Int485 St ID 6 aa EN Si Event H Trip A Result y mo 5 7 4 Parameter File Function to edit a parameter of the drive and save it in a form of a file in off line How to create edit and save a parameter file is described 5 7 4 1 Create Parameter File Create a new parameter file Menu Select File gt Parameter gt Create Parameter File Select Model MODEL VERSION 2 20 Standar w The window to select a model and version supported in Drive View 7 Select a model and version of a parameter file you want to create and click the OK button Anew parameter file will be added to the tree information window LS industrial Systems 2 3 Drive View 7 EN Newrile_iG5A_2 OFF ALL File Drive Configuration Help E SS amp e E E FE Ea New Open Save d Red Report Communication Upiosc i Compare Trend DRIVE EXPLORER Sj DRIVE VIEW 7 G
4. Drive View 7 5 Type the folder name you want to install or click the Browse button to select an installation folder i Browse for Folder Browse C Program Files LSS 6 To browse the size of the disc you want to install click Disc Cost i Drive View 7 Disk Space The list below includes the dives you can install Drive View d to along with each drive s available and required disk space Volume Disk Size Available DE B OB TGB 45GB TOGE 5149MB 70GB 44GB 117GB 99GB 114GB 49GB a aa d r PN The system s disc size available space and required space will be displayed The required space for installing Drive View 7 is about 65MB 7 Select whether to open Drive View 7 to the entire user of the system or to use it exclusively 8 If you click the next button the window to confirm installation will appear GG Drive View 7 Confirm Installation The installer is ready to install Drive View on pour computer Click Next to start the installation 9 If you are ready for installation click the next button 6 LS industrial Systems Drive View 7 10 Drive View 7 will be installed j Drive View 7 Installing Drive View Drive View 7 is being installed Please wait j Drive View 7 Installation Complete Drive View 7 has been successfully installed Click Close to exit 3 3 Complete installation a an Drive View 1 If you open the program menu
5. Graph Monitoring Menu Select Function gt Stop Trigger Mode Trigger monitoring stops 8 1 2 7 Graph Monitoring Mode Function to ban all of parameters except the registered ones from being inquired during the graph monitoring This function is used to monitor them in the condition where the loads generated by other parameters communication are blocked at most Graph Monitoring Menu Select Function gt Graph Monitoring Mode The graph monitoring mode is displayed in the status bar at the bottom of the main screen All inquire functions except controlling will stop To cancel the monitoring mode click the graph monitoring mode menu In addition the monitoring mode is cancelled when you close the graph monitoring window Notice In the graph monitoring mode it is impossible to inquire all of the parameters supported by the main screen or to update the status value of the drive Only controlling the drive is allowed 99 Drive View 7 TTT 8 1 2 8 Y Axis Auto Scaling Graph Monitoring Menu Select Configuration gt Y axis Auto Scaling Function to allow Y axis to move automatically according to the setup channel value If this value is not checked the value of Y axis will be adjusted to the minimum value and the maximum value designated by the user 8 1 2 9 View Grid Graph Monitoring Menu Select Configuration gt Show Grid Function to show or hide Graph Grid 8 1 2 10 View Label Graph Monito
6. 100 0 10000 100 0 1000 0 100 0 O ci ZU MA Value Unit 100 0 Set up a parameter that conforms to Analog Output 0 0 5 msec 0 0 Drive View 7 8 2 2 11 Install Click the Install level button to display the installation window Wizard Control Mode Default V F Value Sensorless 1 Torque Control Default No Value Yes Torque Boost Default Manual Value Auto Acc Pattern Default Linear Value S curve Dec Pattern Default Linear Value S curve 5 parameters are changed Drive 485_6 will change parameters Unchanged parameter will set default value Click Install Button The changed content of the parameter will be displayed Run Wizard button The screen turns into the screen to set up wizard This function is used for additional change Install button The parameter content that are set up in Wizard will apply to the drive LS industrial Systems 6 T Drive View 7 8 2 3 Download Click the Install button to download the parameter setup to the selected drive Wizard Control Mode Default V F Value Sensorless 1 Torque Control Default No Value Yes Torque Boost Default Manual Value Auto Acc Pattern Default Linear Value S curve Dec Pattern Default Linear Value S curve 5 parameters are changed Drive 485_6 will change parameters Unchanged parameter will
7. 54 Drive View 7 8 1 2 Description on Menu 8 1 2 1 Start Monitoring Graph Monitoring Menu Select Function gt Start Monitoring Graph monitoring will start Once monitoring begins the recording icon and the triggering icon become active so that the user may start recording and triggering 8 1 2 2 Stop Monitoring Graph Monitoring Menu Select Function gt Stop Monitoring Monitoring will stop Once monitoring stops the recording icon and the triggering icon become inactive Also the marker becomes active to show the value of each channel 8 1 2 3 Start Recording Graph Monitoring Menu Select Function gt Start Record Once recording starts channels and their values are recorded at every preset recording time Recording is saved to a file in the recording file path A symbol is flashing during the recording Also the recording counter shows the number of the channels and values that are currently recording 8 1 2 4 Stop Recording Graph Monitoring Menu Select Function gt Stop Record Recording stops 8 1 2 5 Start Trigger Observation Graph Monitoring Menu Select Function gt Start Trigger Mode Trigger monitoring starts Once triggering starts the screen will be saved at the time when the channel value becomes either higher or lower than a certain level designated by Trigger Setup The screen is saved to a file in the trigger screen saving file path 8 1 2 6 Stop Trigger Monitoring
8. 6 6 6 1 6 6 2 6 7 6 7 1 6 8 6 8 1 7 1 7 1 1 7 2 7 2 1 7 2 2 7 3 7 3 1 8 1 8 1 1 8 1 2 8 1 2 1 8 1 2 2 FUNCION E 32 EXPOLIO cuasi ir ts 32 SE LID FASC A AAE EE E A AA A E A AA EEA S E AE A 33 ELELE EE 34 Du A A PP 34 Monitor and Control lan E 35 MONOT DNVG oerna EE A EEEE EEE A EAEE 35 OM IR e UE 36 Reverse RUD FOV OI E 36 PRS SU SEO ME 36 Fonward RUN Tele EE 37 PRUE AUS EE 37 Description on Icon and KT E TC 37 Drive Detail IMOMMAUON iii aia 37 Open Detail Information Window ococcicciconnocncccoccec a of Displayed Detail Information Hems cocinar 3 8 Ale lee i a a i ee en ee ee ee eee 4 1 Select and Operate APOCO usara ads 4 1 Inquire and Change Parameter Valuc ssssssssssssesssssensssnssssnesssnensscenssenssceseeeeseneeseneeseeeenesseoenesoeseseenensenenssnensees 43 Parameter IMO MALO ii a 45 Parameter COUN ccoo ias 45 Inquire and Change Parameter ValUue ssssssssssssessssssessneessnsesssseeeneseseeeesseoeseeoeseeeeneseenesenaenesoeseneesenorsenoesenases 46 User GUI E 48 Inquire and Change Parameter Valuc sssssssessssssssssesssssnssssnenssnensscensssenseoeseseeseneeseneeseeeenesseoenesoesesoenenennenssneneses 48 EEP EE 50 Save 10 CEPR ON orir E tanaion 50 ONET STEES ae E EEEee 5 nn E E E A A E 5 1 Je EVO 5 1 A O A 52 Je UC e DE 52 deca Detail MiP E 52 PRS UN EEN 53 MAUNE RESON EE 53 PAA OR DAN FONCIONS E 54 Graph MontoRna MENO rica ii 54 SS DA DESCIPUION ON ET
9. AResult 6 2 Control Drive It plays a keypad role giving commands to the drive Icons to give commands are located in the upper right and they are active only when any drive is selected Only when any drive is clearly selected through selecting its information or its parameter the drive will be considered to be selected and the selected drive will be displayed at the tile area in the upper left Reverse Reset Stop Forward 6 2 1 Reverse Run reverse If you select a drive and click the reverse icon the command to run reverse will be sent to the drive and the result will be checked through its running status 6 2 2 Reset Stop lf you select a drive and click the reset stop icon the reset command will be given when any trip occurs or the stop command will be given in case that the drive is running 3 6 LS industrial Systems Drive View 7 6 2 3 Forward Run forward If you select a drive and click the forward icon the command to run forward will be sent to the drive and the result will be checked through its running status 6 3 Run Status An easier monitoring is possible since the run status of the drive is displayed with the relevant icon along with description 6 3 1 Description on Icon and Status vw Stop The drive now stops Communication Error Communication with the drive is not possible now 3 o Trip Current some trip occurs Run forward The drive now runs forward This icon appears when the drive gra
10. E ANNE Ki Ki gt 100 50 gt en N D 100 100 Output Frequency EN Command Freq EN PID Reference EN Analog Output 1 EN setting 39 Drive View 7 Eo 5 Output Gage Select either Output Frequency or Output Speed to monitor Select either Output Frequency or Output Speed through combo Custom Min Max If it is difficult to monitor since the range from the maximum value to the minimum value is too wide the user may adjust the maximum value and or the minimum value of the gage e Double click a gage to display the Custom Min Max window Custom Min Max Output Frequency Max 400 00 Hz 400 Min 0 00 Hz 0 Set eo After typing a maximum and minimum value click the set button e The gage to which the changed maximum and minimum value applies will be displayed 6 Select Monitoring Gage Three gages are provided and the user is allowed to select a monitoring parameter Select a monitoring parameter from the combo Custom Min Max If it is difficult to monitor since the range from the maximum value to the minimum value is too wide the user may adjust the maximum value and or the minimum value of the gage Double click a gage to display the Custom Min Max window After typing a maximum and minimum value click the Set button The gage to which the changed maximum and minimum value applies will be displayed 7 Change Parameter Value lf a parameter is changeable according to the type of the selected monitoring parameter th
11. E User Group Ey 51 SA Band E NewCustom_1 Ey 52 SEQ Band 9 4 L5485_01_iG54 Ex 53 TD level il 6_iS E Parameter File LE Event ET Trip Result 2009 04 27 14 02 06 N Event Trip Result The dragged and dropped parameter will be added to User Group Adding parameter is only possible to the same drive model Dropping to other drive is not available Bel S485 Station No 1 S 1 5 Y2 50 User NewCustom_11 File Drive Configuration Help EGA a A E BE ER Ba E New Open Save Undo Redo Report Communication Upload Download Compare Trend DRIVE EXPLORER a 34 DRIVE VIEW 7 Connection a di L GA 1145 po Application o ff Parameter Group E DIO Ey PAR EJ FUN E CON Ey EXT Ey Alo E USA EJ 2nd Ey E L By SYN EJ WEB EY User Group i 2 NewCustom_l He 4 LS485_01_ G54A yi 6_iS E Parameter File E Event 88 Trio Protocol Station No IP Model Capacity Trip Result 2009 04 27 14 02 06 485 6 iS7 800 W Option Trip 1 1 6 LS industrial Systems Drive View 7 2 Delete Parameter Select a parameter to delete from User Group Press the Del Key of the keyboard The selected parameter will be deleted from User Group Hel S485 Station No 1 S 1 5 Y2 50 User NewCustom_1 File Drive Configuration Help a a Eq 8 a e B New Open Save Undo Redo DRIVE EXPLORER E 3 DRIVE VIEW 7 Connection Sasi LS485 A LA O Not Use
12. Only during running Read Write Result Parameter Write Failure etc and other status are displayed 49 Drive View 7 6 8 EEPRom When changing parameter values of the drive with DriveView7 communication the original drive value is displayed instead of the changed one at the next time you turn on the system because the changed value by such communication applies only to the drive s RAM To solve this problem this function is to remain the changed value by saving it to the drive s EEPRom 6 8 1 Save to EEPRom Select a drive you want to save to EEPRom available only for iS7 Menu Select Drive gt Save to EEPRom Active only when selecting iS7 Save to EEPRom P Station Mame 485_1 Will vou save the Keypad parameter to EEPRom The message box to ask whether to save to EEPRom will appear Click Yes to save it to EEPRom Save to EEPRom E Station Mame 465_1 Writing to EEPRiom has completed The result will be displayed 5 0 LS industrial Systems Drive View 7 7 Other Screens 7 1 Event Events such as adding deleting or controlling the drive are recorded and displayed Events are collected while Drive View 7 is running and the existent events are deleted when it ends 7 1 1 Inquire Event Click an event you want to inquire in the navigation window or click the event tap in the result information window to display the result in the result information window
13. activate only if any drive is selected Menu Select Drive gt Download Download window will appear 485_1 Download Download File gt Drive Mu Documents Mu Computer a File name MWS defualtdmp vw My Network Files of type Parameter File dmp Ww Click the Open button 485 1 Download Download File gt Drive The file to be downloaded will appear Click the Start button The status display window or the progress bar of the main window shows the progress to download the parameter value from the file to the drive The work will end after showing completion message LS industrial Systems EN Drive View 7 5 7 3 Compare Function to compare between drives between drive and file between files between drive s basic values factory values and between file s basic value and parameter value and to show wrong parameter values in the result display window Menu Select Drive gt Compare The screen to Compare Parameter will appear Compare Parameter Target1 File O Drive Target2 File O Drive O Default value The screen to select subjects to compare will appear Select Target 1 and Target 2 Click the search J button to select files Parameter File Open Target1 Look in C Parameter Group My Computer File name My Network Files of type Parameter File dmp w The selected files are dis
14. after installing Drive View 7 Drive View 7 Menu will be created t ZB OriveView f DriveView Help de DriveView Manual 2 Three shortcut icons will be created under the menu of Drive View 7 Execute Drive View 7 Execute Help File Execute Manual File 3 Drive View 7 execution Icon will be generated on the Desktop Fi Ed EME LS industrial Systems T Drive View 7 4 Description on Screen 4 1 Main Screen The main screen a screen displayed when Drive View 7 runs consists of Title Menu Toolbar Control Navigation Window Parameter Edit Window Result Display Window and Status Display Window Be S485 28 T SY YS 2 50 Connection File Drive Configuration Help E 3 D Ae 9 A Af P BV F BW P RB New Open ave Re Report Communication Upload Download Compare Trend Reverse Reset Stop Forward DRIVE EXPLORER 8 DRIVE VIEW 7 Station Address IP Drive Name Connection y i V 200V 3 ph O Stop Sasi 15485 i i 200V 3 ph Stop 2 145 El i 200V 3 ph Trip a 4_iG5A a 6197 E Parameter File LE Event ET Trip ES Result Occurred Time Description PE 2009 04 24 10 22 12 LS485 Station No 6 Add BE 2009 04 24 10 22 02 LS485 Station No 6 Delete fa Event A Trip F4 Result 7 keier 1 Title The name of the selected drive or the current window 2 3 4 5 Parameter Edit Window As the main window to display the selected item from the navigation window it Menu and Toolb
15. lempriDownloadFileyyviY5 Detaultdmp File Drive Configuration Help D Mi a e B Ex DRIVE EXPLORER a 8 DRIVE VIEW 7 Connection 1 P1 define Sasi LS485 2 P2 define CRT 115 3 P3 define mz 4 L5485_01_iG54 4 P4 define S i 6_iS7 5 P5 define SE Parameter File 6 P6 define 4 E NewFile_iG5A_2 7 P7 define E D 2008_ProjectSource tb 9 Terminal LPF PE Event 41 AX1 Define ET Trip DIO 42 AX2 Define Result DIO B 43 0C1 Define DIO 46 Relay mode 47 ZSDlevel 48 ZSD Band 49 SD level 50 SD Band 51 SA Band 52 SEQ Band 53 TD level 54 TD Band 55 TimerOn Dly 56 TimerOff Diy r ms PPEP OE A eo OE a ee En Eo ES Event Trip Result lf the edit box appears type an appropriate parameter value At this time the value exceeding the maximum value or lacking the minimum value will not be entered Fe DY ZU06_Project Sourceryybinyy lemp Downloade yivo_Uetault amp File Drive Configuration Help ps pz Eq GA New Open Save DRIVE EXPLORER a 8 DRIVE VIEW 7 Connection wig LS485 oil LS az 4L5485_01_iG54 yi 61S SE Parameter File aE NewFile_iG54_2 5 D2008_ProjectSource Wb Event F Trip Result 3 Event Trip Result 2 6 LS industrial Systems Drive View 7 If neither the combo nor the edit box appears the parameter shall be deemed as a read only parameter 2 Undo Redo Function to cancel the typed value and to retype a new value during editing a par
16. zone Dalian China e mail lixkOlgis com cn Tel 86 411 8273 7777 Fax 86 411 8730 7560 LS Industrial Systems constantly endeavors to improve its product so that Information in this manual is subject to change without notice E LS Industrial Systems Shanghai Co Ltd gt gt China Address Room E G 12th Floor Huamin Empire Plaza No 726 West Yan an Road Shanghai China Tel 86 21 5237 9977 E LS Industrial Systems Wuxi Co Ltd gt gt China Address 102 A National High 4 New Tech Industrial Development Area Wuxi Jiangsu China e mail Xugh lgis com cn Tel 86 510 534 6666 Fax 86 510 522 4078 E LS Industrial Systems Beijing Office gt gt China Address B tower 17th Floor Beijing Global Trade Center building No 36 BeiSanHuanDong Lu DongCheng District Beijing China Tel 86 10 5825 6025 E LS Industrial Systems Guangzhou Office gt gt China Address Room 1403 14F New Poly Tower 2 Zhongshan Liu Rad Guangzhou China e mail zhangch lgis com cn Tel 86 20 8326 6754 Fax 86 20 8326 6287 E LS Industrial Systems Chengdu Office gt gt China Address Room 2907 Zhong Yin B D No 35 Renminzhong 2 Road Chengdu China e mail hongkonk vip 163 com Tel 86 28 8612 9151 Fax 86 28 8612 9236 E LS Industrial Systems Qingdao Office gt gt China Address 12th Floor Guodong building No52 Jindun Road Chengdu China e mail bellkuk hanmail net Tel 86 532 580 2539 Fax 86 532 583 3793 Drive View 7 for S7 IP5A iV5 G5
17. 9 485 A Stop Control User Group Ef 2009 04 27 16 01 47 485 A Forward Control Parameter File ES 2009 04 27 16 01 44 485_4 Stop Control FE Event ES 2009 04 27 16 01 35 485 4 Reverse Control fy Trip FS Result Es E Es Es E E Y Event A Trip AResult al Systems 3 5 Drive View 7 3 Monitor Node for each Communication Mode To monitor nodes for each communication mode click the communication mode you want to monitor You may monitor the connection information on those drives connected in the selected communication mode Be Drive View 7 Connection File Drive Configuration Help ES fA q A PUE TT amp EB oe RB TC New Open t Communication ad Compare Trend Help DRIVE EXPLORER a EH DRIVE VIEW 7 Protocol Station Address IP Drive Name Drive Model Capacity Voltage Run Status Connection EI 4 15485 01 G5A 75W 200V 3 ph Stop CARE dig LS485 6 iS7 800 W 200V 3 ph Trip ag L54865 E 415485_01_1G54 Application BS Parameter Group Ey DRV Ey FUI Ey FU2 Ey 1 0 ig User Group el 6_iS Application BS Parameter Group s Event E Ex E E E E Ex E Ex E E Occurred Time Description Ey E 2009 04 27 16 01 49 485 A Stop Control W User Group Ef 2009 04 27 16 01 47 485 A Forward Control Parameter File eG 2009 04 27 16 01 44 485_4 Stop Control CE Event E 2009 04 2716 0135 4854 Reverse Cen fy Trip FS Result Event A Trip
18. A Series 2009 5 LS Industrial systems Co Ltd 2009 All Rights Reserved
19. Break dra DRV 8 Tra Ref Src Keypad 1 Diameter drw DRV Y 9 Control Mode V F MainSpeed drw DRV 10 Torque Control No OutFreq drw DRV 11 JOG Frequency 10 00 Hz PID Control drw DRV a 12 JOG Acc Time 20 0 sec PID Source drw DRV 13 JOG Dec Time 30 0 sec A Parameter Group DRV Ey 14 Motor Capacity 0 75kW Ey DRY DRV 15 Torque Boost Manual Ey BAS DRV 16 Fwd Boost 2 0 Ey ADV DRV 17 Rev Boost 2 0 Ey CON DRV y 18 Base Freq 60 00 Hz Es IN DRV Ey 19 Start Freq 0 50 Hz Ey OUT A EE SSS Es COM DRV Ey 21 Hz Rpm Sel Hz Display Ey APP BAS Ey 1 Aux Ref Src None Es AUT BAS 2 Aux Calc Type M G A Ey APO BAS Y 3 Aux Ref Gain 100 0 PRT BAS 3 4 Cmd 2nd Src Es M2 BAS 5 Freq 2nd Sre Keypad 1 4 User Group BAS Y E Tra 2nd Sre Keypad 1 E Parameter File BAS 2 7 V F Pattem Linear CE Event BAS 8 Ramp T Mode Max Freq ET Trip BAS 9 Time scale 0 1 sec Result BAS y 10 60 50 Hz Sel 60Hz BAS EY 11 Pole Number 4 BAS 12 Rated Slip 40 rpm BAS 3 13 Rated Cur 36 A BAS 3 14 Noload Cur 16A BAS y 15 Rated Volt DN BAS y 16 Efficiency 72 BAS Y 17 Inertia Rate 0 BAS yy 18 Trim Power 100 BAS 19 AC Input Volt 220 V Event Occurred Time 2009 04 27 16 24 58 EE 2009 04 27 16 24 57 Event Trip Result LS industrial Systems 4 5 Drive View 7 6 6 2 Inquire and Change Parameter Value 1 Retrieve the entire parameters of a group 0 Double click the name of a group to inquire If you wan
20. Drive View 7 S W User Manual Use this board after read Safety Instruction of this manual carefully before using and follow the instructions exactly Please hand this user manual to end user and trouble shooting manager After read this manual keep it at handy for future reference LS Industrial Systems Drive View 7 Contents 1 HATE OGUCUON OF DIVE VIC WF E E A E A E A E A E E E E EA 4 2 System CONTIG UAW e EE 4 3 or AA e A E o e 5 3 1 Prepare TOP EIS Cea ANA tasado ticos 5 3 2 uu EE 5 3 3 ene ET tala ie ee S 7 4 PSS CMU EK E 8 4 1 ORIENT EE 8 5 Description on RUN and IS TUNCUONS nc 9 5 1 NO 9 5 2 Beien fe 10 521 Setup COMMUNIC AMONN esseere aaa 10 5 3 ro eh RE 11 53 1 Add Modbus TCP DAVE ere 11 592 Add Modb s RTU DIN ads 12 3533 Addl 85 Bee 12 5 4 Delete hee 13 5 5 ue e EE 14 90 1 Setun Lanquade smilies 14 59592 SOLUCION nadas 14 5 6 USC ele cnt iii 15 561 CRA ISS i E 15 MOST User ler tocata race 18 503 SAC USA AMO io ad 19 507 Close USEI FIE ad 19 5 7 SCC i ee 20 r i E Te E 20 br RR e UM 2 1 a e ue E 22 Oe fs cf o ooo 23 5 7 4 1 Create Parameter Fl ns 23 5742 OpenParameter TT 24 5 7 43 Edit Parameter d TEE 25 5744 S ve alec dg ee 27 5749 Close Parameter TN 28 5 7 4 6 Convert File from ISS ON 28 5 8 REDO E 3 1 5 84 RUN 0 6 EE 3 1 Drive View 7 MO 9 8 2 5 8 2 1 5 8 2 2 5 8 2 3 5 8 2 4 6 1 6 2 6 2 1 6 2 2 6 2 3 6 3 6 3 1 6 4 6 4 1 6 4 2 6 5 6 5 1 6 5 2 6
21. He Drive View 7 Connection File Drive Configuration Help A a A New Open Save Red DRIVE EXPLORER Sj DRIVE VIEW 7 ga Connection a dd LS GA 1 145 ez 4215485011654 D r FS Result ER PE t Communication E RB LZ i Compare Trend Station Address IP Drive Name L5485_01 Occurred Time JE 2009 04 27 17 11 29 E 2009 04 27 17 11 26 E 2009 04 27 17 11 25 BE 2009 04 27 17 11 24 B 2009 04 27 17 11 22 E 2009 04 27 17 11 20 ES 2009 04 27 17 11 06 SE 2009 04 27 16 24 58 BE 2009 04 27 16 24 57 eerie fren Description 485 1 Stop Control 485_1 Forward Control 485 1 Reverse Control 485 _1 Stop Control 485 1 Forward Control 485 1 Reverse Control LS485 Station No 1 Add 485 A Stop Control 485 4 Reverse Control LS industrial Systems 5 1 Drive View 7 7 2 Trip When any trip occurs in the connected drive information on the trip will be displayed in the trip information window 7 2 1 Inquire Trip Click a trip you want to inquire in the navigation window or click the trip tap in the result information window to display the result in the result information window Fe Drive View 7 Connection File Drive Configuration Help Ey A a e E CS Fo E RB 4 New Open Sue eport Communication Compare Trend Help DRIVE EXPLORER a 38 DRIVE VIEW 7 Station Address IP Drive Name Drive Model Capacity Voltage Run Status E A Connection 1 iV5 5 5 KW 200V 3 ph
22. New Convert dmp File Drive Configuration Help D ta amp A Af E By EN EN H 4 New Open Save Undo Redo Report Communication Upload Download Compare Trend Help DRIVE EXPLORER SQ DRIVE VIEW 7 Connection Sasi LS485 Hei 1 15 zz 4L5485_01_iG54 Hei 6157 2 Parameter File e E NewFile_iG54_2 au E D 2008_Projecti Source tb FE Event fey Trip Result WE EE EE A E E O O E E gt Event Trip Result 3 0 LS industrial Systems Drive View 7 5 8 Report Function to on line Drive and off line Parameter File parameter values in a form of report Functions related to editing and printing reports are described 5 8 1 Run Report Select a parameter group you want to display in a form of report from the tree information window fe Sate station Nosh sve VIL MM Fie Drive Configuration Help IB WD o A e E RK Er ER D W ZC y Report Communcaton Upload Dommibad Compare Trend Heir DRIVE EXPLORER E KC DRIVE VIEW 7 d Connection 3 1 frega 100 a 2 Terga a 100 i di Sg 5 WI Monto 5 11340501654 ES 6 Vi Polarly EA 6 187 a TVi Fee Application Eg V1 Vobsl Pi watir cp 3 9 VI Peery a 10 Wl otk E3 11 vi Pety H 12 Vi VokxT 2 13 Vi Percy Sy id VI An H 15 Wl Pert y 16 VI Invertir 3 17 Wl Quta Ej 20 11 Mortara Ey M D Pole Ej 2 11 fs Ej Bor E User cae Ej 24 11 Percy BE Parameter Fila Es 5 ICurxl e ES NewPlle_ 16542 Ey 26 11 Perey E BS Dwi Project Source ki enee EE Event Pg Trip TS R
23. POD 2006 Project source bin TempyDownloadrile Wi 5_Detault damp File Drive Configuration Help E 58 a e E E EN E HN RW 2 New Open Save do Redo Report Communication Uploac Compare Trend Help DRIVE EXPLORER a 34 DRIVE VIEW 7 Group Name Code Parameter Name Connection Y 1 Bi define Ssa 15485 Ey 2 P2define a 1145 Y 3 P3 define 2 415485_01_ G54 Y 4 P4 define Al 6 187 Y 5 P5 define E Parameter File Y E P6 define E NewFile_iG54_2 Y 7 P7 define SEA Y 9 Teminal LPF Ev Y 41 AX1 Define Tri 42 AX2 Define Re 4 43 OC1 Define 4 46 Relay mode d 47 ZSD level y 48 ZSD Band 49 SD level Y 50 SD Band Y 51 SA Band Y 52 SEQ Band Y 53 TD level 54 TD Band Y 55 TimerOn Diy Y 56 TimerOf Diy f gt Event Trip Fi Result Pi 5 7 4 3 Edit Parameter File 1 Parameter File Configuration The parameter file will be added to the tree information window under the parameter file category and its file path will be also added along with it When selecting the file its entire parameters will be displayed If you select a group under a certain file only those parameters that belong to the group will appear 1 Edit Parameter Value A parameter list will appear in the parameter information window and if you click a value it will turn into the edit mode The combo will appear for editing message and you may select from the combo list to edit LS industrial Systems 2 5 Drive View 7 Fe DY ZU06_Project source bN
24. Parameter File The window to ask whether to save the parameter file will appear Drive View 7 Mew Parameter File i C Program Files L515 T Drive View 7 Weer Group thPSA Process DI dp Do vou want to save the File If you click the OK button the parameter file list will disappear after getting through the same process with the saving process If you click the Cancel button the parameter file list will disappear without saving 5 7 4 6 Convert File from iS5 to iS7 Function to covert a parameter file for iS5 used in Drive View 3 0 to a parameter file for iS7 used in Drive View 7 At this time the parameter value for iS5 will be converted and saved to the one that fits to S7 Note This function is supported only its version is higher than iS5 Version 2 12 Menu Select File gt Convert from iS5 to iS7 parameter file The window to convert Data File from iS5 to iS7 will appear Convert Data File from iS5 to iS 55 Parameter File iS Parameter File ke Select and enter an iS5 parameter file after clicking search button J 155 Open Parameter file Look in O Parameter Group 33 Default par 3 S5 par SIb Lpar SIb 2 10 par 3 iS5 2 11 par BEIA 155 2 13 par 3 S5_Default par My Computer A File name is 52 12par My Network Files of type 1155 Parameter file par 2 8 LS industrial Systems Drive View 7 D parameter file have
25. SS Model Ved 102 0 e ik Y Je arameter alt efault Unit l LL Fregan loo OO Ha 2 E lU 1 Monitor Y O A IN 1 Polarit Unipolar CisSS 1 Filter 1 Volt x1 1 Perc y1 WO VE Voltx2 A LU VE Percy O A A LS Voltxt CC C iINO 13 VE Percyt HS 14 VT Voit x2 10 00 1 Perc y2 1 Inverting 1 Quantizing Monitor m Polarit 2 3 4 5 j Oge Pi fn 6 V1 Polarity BV Volt GV Percy lt p p lt p lt 22 Filter 23 Curr x 24 Perc yt Curr x2 3 2 LS industrial Systems Drive View 7 Output in HTML form 3 C Program FilesWSISWrive View 7 Parameter Group iS5 Parameter File iS7_ProjectO1_Report htm Microsoft File Edit View Favorites Tools Help Back sl a A P Search 5 7 Favorites ES R da z LJ Address C WProgram Files WLSISWDrive View 7WParameter Group WiSS Parameter File WiS7_Project01_Report htm LSIS CP 2009 05 25 10 54 47 Ki mun Bahn iS 1 02 485_1 Online Parameter Group IN 1 Freq at 100 60 00 Hz 2 Torque at 100 100 0 5 VI Monitor Y 0 00 y 6 VI Polarity Unipolar ri VI Filter 10 msec 8 VI Volt x1 0 00 Y g VI Perc y1 0 00 10 VI Volt x2 10 00 Y 11 VI Perc y2 100 00 12 VI Yol vi 0 00 Y 13 VI Perc vil 0 00 14 VI Yol x2 10 00 Y 15 VI Perc y2 100 00 16 AO ee No 17 1 Quantizing 0 04 20 11 Monitor m 0 00 m 21 II Polarity Unipolar 22 11 Fi
26. Stop Easy LS485 4 LS485_01 G5A 7 5 KW 200V 3 ph Stop ml IN 6 iS7 800 W 200V 3 ph Trip e 4 L5485_01_iG54 CR 6_iS E Parameter File Occurred Time Drive Name Protocol Station No IP Model Capacity Trip Lg 2009 04 27 17 15 12 485 6 iS7 800 W Option Trip 1 ey 2009 04 27 17 14 59 485 6 iS7 800 W Option Trip 1 N Eve A Trip A esult Fi 7 2 2 Inquire Detail Trip Function to allow the user to inquire the state of the trip and additional trip Information when any trip occurs 1 Execute Detail Trip 0 Double click a trip you want to inquire its detail information in the trip list e The detail Trip Information window will appear Detain trip Information Occurred Time 2009 04 27 17 14 59 Protocol Station No IP 485_6 Node Name Model Name iS7 Capacity 800 W Trip Information Status Information No Trip Name Parameter Value Unit k 1 Option Trip 1 Ey Output Frequency 0 00 Hz E3 Output Current 0 0 A Ey Inverter State Stop E3 DCLink Voltage 286 V Ej Inverter Temperature 29 C Ey Digital Input Status b0000000 B Ey Digital Output Status b000000 B 0 Detail information on the state when the trip took place will be presented 5 2 LS industrial Systems Drive View 7 2 Displayed Items Occurred Time Time when the trip occurs Protocol Station No IP The communication mode and Station No IP of the drive is displayed Model Name The model name is displayed Capacity The capac
27. am you want to inquire eo The system will retrieve related parameters from the drive and display them in the diagram fe CoS staton No e oe ose YOR PII Spure m drel E y fF fF RW TL Camana Ls Denia Compare Ted Pep HIVE EXPLOHER a y DIE VIEW 7 D Connection e Sl LP FAD Pai Spee e A ALLES DEA o A8 E EI L Eepp d d 3 Y Aepkcagon Ara dee D Brenk gea ll Dimes dre Mirad diw D Orga dre H PO Central dire a RE Parameter Group Lier Group Be Pasarelas Filo DE Evora eT Tire ES emh EPI Fb rop valve 2 Inquire and Change Parameter in the diagram e Click the name of a parameter button to inquire in the diagram keypad e The system will retrieve related parameters from the drive and apply them to the diagram The parameter editor window will be displayed EEE Solia Application APP 22 PID P Gain 50 0 1000 0 Default Value 50 0 0 0 red aime e Change values and click the Write button e The changed parameters will apply to the drive and the result will be displayed in the diagram and the editor s status display window LS industrial Systems 4 3 Drive View 7 WT 44 3 e Description on Editor Parameter Editor Message is displayed in the combo and the window to type numbers is displayed for normal input Type a value to change within the range from the minimum value to the maximum value Prev Move to the previous par
28. ameter Menu Select File gt Undo Redo If you select to Undo all of revisions will be canceled If you select to Redo the canceled revisions will be re executed Undo Redo operate in the unit of parameter file When selecting other parameter file the revision of the relevant file has influence 5 7 4 4 Save Parameter File A parameter file is saved in a form of a file Menu Select File gt Parameter gt Save Parameter File The window to ask whether to save the file will appear only when the parameter file has some revision Drive View 7 Mew Parameter File Oo C Program Files St WDrive View Z dl ker Group We deFualt dmp Do vou want bo save the File Click the OK button Once the window to input the file type the parameter file information and click the save button The extension of parameter files is dmp Save Parameter File Save in 3 User Group Elevator Application fan Application Pump Application Ki G5A_Program dmp E iP54_Process_01 dmp Ki iS _Process_02 dmp KE v5_Crane dmp KE i 5_defualt dmp Eivs_Project_03 dmp ke File name V5_defualt dmg My Network Save as type Parameter File dmp e LS industrial Systems 2 T Drive View 7 5 7 4 5 Close Parameter File Close the selected parameter file Select a parameter file you want to close from the tree information window Menu Select File gt Parameter gt Close
29. ameter from the currently displayed parameter in the diagram Next Move to the next parameter from the currently displayed parameter in the diagram Max Min Default Value The maximum minimum and default value the value set in the factory are displayed Read A parameter of the drive is retrieved and displayed Write A parameter value of the drive is written Close The editor window is closed Status Display Window Parameter Type Read only Read Only during running etc Read Write Result and other status are displayed Drive View 7 6 6 Parameter Information 6 6 1 Parameter Group Those parameters available to be inquired and changed in the drive are classified into groups and provided in a type of list When Parameter Group is selected the entire parameters will be displayed When a certain group is selected only those parameters that belong to the relevant group will be displayed E S485 Station No 6 SY is7 YI 02 ALL ST T File Drive Configuration Help e e PO E AAE w 8 a New Open Save d Red Report Communication Upload Download Compare Trend Help Reverse Reset Stop Forward DRIVE EXPLORER H DRIVE VIEW 7 Group Name Code Parameter Name Default Unit Connection DRV Y 1 Cmd Frequency 0 00 Hz Sig LS485 DRV y 2 Cmd Torque 0 0 mz 2 4 L 485_01_iG54 DRV 3 Acc Time 20 0 sec Edil 6 157 DRV j 4 Dec Time 30 0 sec a Application DRV 2 E Cmd Source Fx Rx 1 AnalogOut drw DRV 7 Freq Ref Src Keypad 1
30. ar Menu and toolbar to select functions Control Drive s control button A NA A Te Te Navigation Window Window to select drive file parameter group and application shows application diagrams or parameter lists 6 Result Display Window Window to display results of event or trip 7 Status Display Window Window to display the current status or process status Progress bar 8 LS industrial Systems Drive View 7 5 Description on Run and Its functions The functions needed for running and operating Drive View 7 are described 5 1 Run Drive View 7 is already installed in the system Run DriveView 7 exe The initial screen of Drive View 7 will appear EE Drive View 7 Connection AE File Drive Configuration Help A ES D A PE RR fF Ff fF SS mm e ma New Open Save Undo Redo Report Communication Upload Download Compare Trend Help Reverse Reset Stop Forward DRIVE EXPLORER 34 DRIVE VIEW 7 Connection E Parameter File LE Event ET Trip FS Result A Event Trip Result LS industrial Systems 9 Drive View 7 TTS 5 2 Communicate Communication setup and drive connection deletion needed for drive connection are described Drive View 7 supports Ethernet and Serial Communication Ethernet communication Modbus TCP is automatically supported without setup Serial communication is connected by two communication methods Modbus_RTU and LS485 5 2 1 Set up Communication M
31. as 55 la MONTON armar AA 55 SIP e tel ari aia 55 Drive View 7 oa zo ees lg ile re le e E 55 9124 Stp RECOrGING ar 55 8125 Stant lee e el e ici lia 55 8126 Stop Migger MONO D 55 9 1 2 7 Graph MORONS MOJO E 55 891239 Y AXIS AV SCING D 56 3129 VIEW E a 5 6 3 Ain PARRA PP On A 56 812 1T Open COPE FIG uri dll 56 HEEN eet 56 Me UU ek OS Asun lolis 57 o t2 14 Save SCOPE Orea lidia noo 57 o k2 I9 COPY e I OA E 97 8 1 2 16 REENEN 57 S12 I7 ODR SCEE en E RA E 57 813 PD SSCHINSUIONT ON FUNG WO INS sist ses ess enn ici 58 Sion CNRS e ne dd iaa 58 Saz DISDIA SCI e A e 59 S133 MOGET Send sicario 60 SECH ONG nana aan 60 8 2 Wizard oa ie 6 1 921 Exec sins aa 6 1 022 Og OL RIT o CIN arranco 6 1 8221 Motor amp COMME e hora ni 62 022 2 Se TOUS unica rada riada 62 9229 o A 63 E E 63 38220 Eeer 64 822060 MU SIO Deco urinaria a 64 82271 DO OUD ost aio ais 65 8220 VIANA IADU ee eee ee ee a cn ee ee er ce ane ene eee eee eee 65 E WEE Nee MUI E 66 82210 Analog e ire TEE 66 B22 TIRS a 67 023 DOWNOI ee ee mene eT eee eee acia 68 jii Drive View 7 oS 1 Introduction of Drive View 7 Drive View 7 is software for engineering LS Industrial System inverter hereinafter Drive It has a function to monitor the devices connected with Drive View 7 in remote and support works necessary for Start up and Maintenance 2 System Configuration Drive View 7 supports three communication modes Modbus TCP Modbus RTU LS485
32. ation mode and IP or station no e Drive It is possible for the user to change the current station name arbitrarily e Change If you want to change rename it and click the change button e Capacity The capacity of the drive is displayed e Voltage The voltage of the drive is displayed 3 8 LS industrial Systems Drive View 7 2 Run Information The current state of the drive is displayed Aun Information Comm State Normal Error Run status Trip Acc Time 20 0 sec Dec Time 30 0 Sec Comm State The communication state of the drive is displayed Either Normal or Error is displayed Run Status One of status among Trip Stop and Run is displayed Acc Time Acc time is displayed Dec Time Dec time is displayed 2 Select Application Application for each drive can be selected Available applications are displayed in the application combo list Initially Not Use is selected select Application pplication Select an application you want to apply and click the change button Diagrams provided at the selected application will be added to Application the submenu of Drive in the Navigation Window O Selecta diagram to inquire and use Refer to the description on applications 4 Select Monitoring Parameter The user can select a parameter to monitor Information is displayed in a form of gage 4 00 Hz 0 00 Hz 50 0 76 4 00 76 i 400 100 100 300 50 50 Ln rol l ol l 200
33. begins flashing when trigger occurs and trigger monitoring starts Elapsed Time lt shows the elapsed time since monitoring starts Time is displayed in a form of 00 00 00 Record Counter lt shows the number of the current recordings since recording begins X axis Time Select a range of Graph X axis time The selection range is from 10 seconds to 1hour Monitoring Time Select a time interval to monitor channels The selection range is from 0 1second to 5seconds A graph will be drawn according to the selected time interval Record Time Select a time interval to record The selection range is from 1second to 1hour Recording is conducted according to the selected time interval 8 1 3 1 Channel Setting Monitoring Channel E Analog Output 1 Data Offset D 0 i PID Reference j 30 a ze f Analog Output 1 0 be Basel Bh Ken Rev Neg Torque Limit Set 0 Channel Setting Display Setting Trigger Setting 1 Monitoring Channel The box 1 in the above figure is about selecting whether to make the relevant channel active or not Pressing the toggle button one time makes it active while another pressing makes it inactive After making it active select a channel you want to monitor in the monitoring channel at the box 2 Select a parameter according to the selected monitoring channel at the box 3 to complete the channel selection Drive View 7 Data The curren
34. dl Application Not Used Parameter Group DIO Ey Not Used Ey DIO ET EEN TE O Ey PAR DIO Ey 41 AX1 Define Not Used Ey FUN DIO 05 Ey CON DIO D pm Ey EXT DIO 05 Alo Ey USA Ey 2nd Ey E L Ey SYN WEB SY User Group O NewCustom_1 ef 4 L5485_01_iG5A Ho 6_iS7 E Parameter File PE Event ET Trip Result Protocol Station No OP Model Capacity Trip 2009 04 27 14 02 06 485 6 iS7 800 W Option Trip 1 N Event Trip Result Be S485 Station No 1 SY 1Y5 2 50 User NewCustom_1 File Drive Configuration Help A a e HB New Open Save Undo Redo DRIYE EXPLORER E E DRIVE VIEW 7 Connection Siig LS485 GA 1 145 Application Parameter Group DIO Ey PAR FUN CON E EXT EY Alo Ey USA Es 2nd Ey E L E SYN WEB User Group Y NewCustom_t az 4 15485_01_1G54 CR 6 157 E Parameter File Trip PE Event ET Trip Result Occurred Time Protocol Station No P Model Capacity Trip 2009 04 27 14 02 06 485 E iS7 800 W Option Trip 1 N Event Trip Result LS industrial Systems 1 T Drive View 7 5 6 2 Open User File Menu Select File gt User gt Open User File Look in User Group O Maker cus Project_01 cus Project_02 cus Project_03 cus Y Project_04 cus Desktop Test_01 cus My Documents My Computer File name 15_Cus01 cus My Network Files of type i87 Custom File cus The screen to open User File will appea
35. dually reduces its speed while running forward or when the drive is running forward 5 Run reverse The drive now runs reverse This icon appears when the drive gradually reduces its speed while running reverse or when the drive is running reverse 6 4 Drive Detail Information This system provides a window to allow the user to monitor detail parameter information for each drive Monitoring Parameter 6 4 1 Open Detail Information Window Double click the relevant drive in the connection information or click the relevant drive in the node information window to move to the detail information window a ado File Drive Configuration Help BS WS pn e S E PE S GZ New Open Communication Compare Trend Help DRIVE EXPLORER 58 DRIVE VIEW 7 Connection app AUU ff Parameter Group Ey FUI Ey FU2 Ey 1 0 Y User Group 2 6_iS i Application 3 5 Parameter Group 3 DRY BAS ADV CON IN OUT Sa COM APP Event AUT Occurred Time Description 2009 04 27 16 01 49 485 A Stop Control User Group E 2009 04 27 16 01 47 485_4 Forward Control Parameter File EE 2009 04 27 16 01 44 485 A Stop Control CE Event Ef 2009 04 27 16 01 35 485 A Reverse Control fey Trip FS Result E Ey Ey Ey Ey Ey E Ey Ey Ex Ey E Event Atrio AResult Select and double click a drive you want to move to the detail information window Drive View 7 The detail information window will appear FE S485 Station N
36. dustrial Systems 1 9 Drive View 7 5 7 Parameter Functions listed in the parameter menu of Drive View 7 5 7 1 Upload Function to bring the parameter setup information from the drive and to save it in a form of parameter file Select a drive to upload The menu will activate only when a drive is selected Menu Select Drive gt Upload Upload window will appear 485_1 Upload Upload Drive gt File Select a parameter file and click the select J button Type a file name to save the parameter value 485_1 Upload Drive gt File Save in Parameter Group Ki v5_Crane dmp O Recent Desktop My Documents My Computer File name M dek dmp My Network Save as type Parameter File dmp Click the Save button 485_1 Upload Upload Drive gt File CWProgram Files WLSIS Drive View 7 Parameter Group WivS_defualt dmp i ka The file to be saved will appear Click the Start button The status display window or the progress bar of the main window shows the progress to upload the parameter value from the drive to the file The file will be saved after completing the upload process The work will end after showing completion message 2 0 LS industrial Systems Drive View 7 5 7 2 Download Function to apply the setup value in a parameter file to the parameter setup information of the drive Select the drive to download The menu will
37. e Setting button will be active to change the value of the parameter Click the Setting button e The parameter control window will be displayed e Type amaximum and minimum value and click the Write button The value will apply to the drive e Once writing is completed its result will be displayed in the status display window Command Freq 60 00 400 00 0 00 Default Value 0 00 Write Parameter Success 0 Use the Read button when you bring back the parameter value from the drive to read it again 40 Drive View 7 6 5 Application In Drive View 7 parameters can be inquired and changed through the graph screen supported by a relevant application depending on the drive s applicable application 6 5 1 Select and Operate Application 1 Select Application e Select Application from the detail screen Refer to detail screen Select Application select Application Application P 2 Display Application Diagram e Once any application is selected the application diagram list supported at the relevant application will be displayed under Application the submenu of the drive a 8 DRIVE VIEW 7 Connection a dd LS485 2 4 15405_01_1G54 CR 6 157 AnalogOut drw Break drw Diameter drw MainSpeed drw OutFreg drw PID Control drw PID Source drw User Group E Parameter File 3 Display diagram screen e Click an application diagram to display the relevant screen A So Sion A
38. e applied 3 Close Changing languages will be cancelled 5 5 2 Setup Screen Drive View 7 screen operation is set up Menu Select Configuration gt Display The dialog to set up screen will appear Communication Mode SR Full Mode Gei Simple Mode Modbus TCP C Modbus RTU LS485 Display Mode Hz Mode O RPM Mode El Refresh Pole E OK El Close 1 Communication Mode Select a communication mode that will be displayed on Drive View 7 screen When Full Mode is selected all of the three communication modes will be selected while they are separately selected in Simple Mode 2 Display Mode Select either Hz or RPM mode 14 Drive View 7 3 Refresh Pole A pole value for each drive will be refreshed and applied It is used when applying changed pole value 4 OK The setup information will be applied and saved Close Changing setup will be cancelled 5 6 User Group The user can create a group to manage parameter separate from the drive s basic parameter group Also the user may save the contents of the user group in files 5 6 1 Create User File Menu Select File gt User gt New User File Be Drive View 7 Connection File Drive Configuration Help D WM a Aa PE RF HB P RW New Open Red Report Communication sd Compare Trend DRIVE EXPLORER 5 DRIVE VIEW 7 Station Address IP Drive Name a Connection 1 4 15485 01 6 Application E Parameter Gro
39. e drive it will activate Type Station No assigned to the drive 3 Station Range Select and type station range when searching with station range You may input 1 at minimum and 128 at maximum 4 All All of the station numbers ranged from 1 to 128 will be searched and automatically registered 5 Add The drive will be added after being searched Close The work to register Modbus RTU Station will end If you click the Add button after typing information the Modbus RTU Drive you type and search will be added to Drive View 7 If you click the Close button the work to add Modbus RTU Station will end 5 3 3 Add LS485 Drive Menu Select Drive gt Add gt LS485 The dialog to add LS485 Drive will be displayed 54685 Station Station Name 20 L5 01 Station No Gi Station Range 1 Station Name Type the drive name you want to register and control in Drive View 7 2 Station No If you click the IP Radio button when registering one drive it will activate Type Station No assigned to the drive 12 Drive View 7 3 Station Range Select and type station range when searching with station range You may input 1 at minimum and 128 at maximum 4 All All of the station numbers ranged from 1 to 128 will be searched and automatically registered 6 Add The drive will be added after being searched 6 Close The work to register LS485 Station will end If you click the Add button after t
40. e individual parameter value e Double click the name of a parameter to inquire in the parameter list The system will retrieve the parameter values from the drive and apply them to the list and the parameter editor will be displayed Parameter Editor BAS 5 Freq 2nd Src Keypad 1 Max Binary Type Default Value Keypad 1 Min Keypad 1 eo Make a change in the editor and click the Write button 4 8 LS industrial Systems Drive View 7 The changed parameters will apply to the drive and the result will appear in the status display window of the editor Parameter Editor BAS 5 Freg 2nd Sre n yl Max Binary Type Default Value Keypad 1 Min Keypad 1 Write Parameter Success 3 Description on Editor eo Parameter Editor Message is displayed in the combo and the window to type numbers is displayed for normal input Type a value to change within the range from the minimum value to the maximum value Up Move to the previous parameter from the currently displayed parameter in the parameter list Down Move to the next parameter from the currently displayed parameter in the parameter list Max Min Default Value The maximum minimum and default value the value set in the factory are displayed Read A parameter of the drive is retrieved and displayed Write A parameter value of the drive is written Close The editor window is closed Status Display Window Parameter Type Read Only Read
41. enu Select Configuration gt Communication Communication setup dialog will be displayed Communication EN Modbus RTU 15485 Comm Port VUN comio Comm Speed 9600 Lee 9600 Parity Bit None None Data Bit 8 Stop Bit 1 Timeout Retry Count D Delay Time Before 1 Flow Control D Delay Time After CU Modbus RTU Set up for Modbus RTU communication LS485 Set up for LS485 communication eo Y Comm Port Select Comm Port to be connected with the drive Only the communication ports installed in the system are displayed If you select None the relevant communication function will not work More than one communication port can not be used for each communication mode Comm Speed Select communication speed Parity Bit Select parity bit Data Bit Select data bit Stop Bit Select stop bit 90066 Time Out Type time to stop communication with the drive 10 Drive View 7 Retry Count Select retry count when failing in communication Delay Time Before Delay Time used when controlling RTS before sending Delay Time After Delay Time used when controlling RTS after sending Flow Control Select flow control OK The setup is applied and the dialog is closed IS Close The dialog is closed without saving setup 5 3 Add Drive Three communication modes Modbus TCP Modbus RTU and LS485 can be used to register the drive How to
42. esull 3 Neven tre frenar lt is possible to select one among drive online parameter groups user groups and offline parameter file s parameter group Menu Select File gt Report The report window will appear and the selected parameter group will be displayed File Function Configuration Code ara Value Default Unit III E EEN 2 Torque at 100 DD 00 J O 5S Vi Monitori Top Ip 6 V1 Polarity Unipolar a sec o vwo 4 VE voltx 7 IS Wi Percy P Ip Wiinverting cose Nivea 1 vi Guang a a 20 i MonitorfmA ip O 22 Jl Der UU 2300 Curr AO E NC 24 NN Percyt OO 27 U Curri Om 29 M Pereyi ___ OO HS O o o dl LS industrial Systems EN Drive View 7 5 8 2 Function 5 8 2 1 Export File Function to save report information in Excel or HTML file Report Menu Select File gt Export File The window to enter the file you want to save will appear Export Report File Save in O 55 Parameter File i57 _Project01_Report xls File name iS _ProjectO1_Report xls My Network Saveastype Excel File ls Select a name and a type of the selected file Excel File HTML File It will be saved in excel file or HTML file Output in excel form ES Microsoft Excel iS7_ProjectO01_Report xls de ey Py iy S B M11 y f ERSTEN User NarKi mun Bahn dodel NdiS S
43. extension Dor and click the Open button after selecting one Click the search button J to select and enter an iS7 parameter file 157 Save Parameter file Save in O Parameter Group gt Ki i S_Crane dmp bd v5_defualt dmp Recent Desktop My Documents My Computer gt a File name is 7_Convert_Project My Network Save as type iS Parameter file dmp v Type the name of the iS7 file It will be saved in dmp file The version of the iS7 file will be converted to Ver 1 00 the relevant data file needs to be in the data file folder Click the save button Convert Data File from 155 to iS7 i55 Parameter File C WProgram Files WLSIS WDrive View 7WParameter Group WiSS_2 12 par iS Parameter File CW Program Files WLSISWDrive View 7WProject File isS W 57_Convert_Project dmp Once the selected file name is entered click the convert button after checking Drive View 7 55 Path C Program Files 4 GI WOrive View 7 Parameter Group iss Parameter File i55_2 12 par is Path CO Program Files L515 Drive View 7 Parameter Group iss Parameter File wis _ drnop Convert Success Convert Success message will appear and it will be saved in the selected path LS industrial Systems 2 9 Drive View 7 Also it will be automatically added to the parameter file list and the list will be displayed Bel UND Project SOUrCE NDIN Temp RS 7
44. hich the screen is saved during the triggering Selection is possible only when triggering stops During the triggering you can not select since it is inactive 8 1 3 4 Other Once monitoring stops the marker becomes active and last data can be seen lf you move your mouse after clicking the marker the value will appear next to the marker But only one channel s value will be displayed next to the marker The color of the marker is equal to that of channel If you want to select other channel select a marker and select other channel in the label to change the marker color with the selected channel color and to show the selected channel value Drive View 7 8 2 Wizard Wizard a function to allow the user to setup main parameters step by step during the initial installation of the drive is described 8 2 1 Execute Menu Select Drive gt Wizard This menu becomes active only when the drive to apply is already selected Wizard screen for each model will be displayed according to the selected models as of iS7 187 Wizard 1 Motor amp Control 2 Speed amp Torque 3 Xcel Time 4 Start amp Stop 5 Digital Input 6 Multi Step Speed 7 Digital Output 8 V1 Analog Input 9 11 Analog Input 10 Analog Output 11 Install Li Motor amp cono 1 Motor amp Control control Mode MaE Parameter Motor Capacity 60 50 Hz Sel Pole Number Rated Slip Rated Curr Noload Curr Rated Vol
45. itten Close The editor window is closed Status Display Window Parameter Type Read Only Read Only during running Read Write Result Write Parameter Failure etc and other status are displayed 47 Drive View 7 6 7 User Group How to inquire and change User Group values is described 6 7 1 Inquire and Change Parameter Value 1 Retrieve the entire parameters of a group 0 Double click the name of a user group to inquire Rita Station No 6 SY 187 VI 02 User NewCustom_11 Pie Ome Configuration Heb HD WW A e B RR BS amp E B New Open Report Commuricaton Upload Download Compare Trend DRIVE EXPLORER Y DRIVE VIEW 7 Group Name Code Parameter Name A Connection OUT Fs 9 AO Ba i L t OUT E E ALLES DI GSA OUT Es AL 6 38 OUT Fy 3 UY Application out E AnalogOut drw OUT Es Break dew OUT Es Diameter drw OUT E MainSpeed drw OUT E OutFreq drw OUT E PID Control dew OUT Es 2A E Es F Es Es Py E E Es Fy Es 10 AD Fier 11 AD2 Comat Y PID Source drw OUT E Parameter Group OUT a OR 17 Opt Parameter 18 Opt Parameter 19 OtParameter10 20 OptParameter11 21 OAPrrameter12 eee EF Tre E Result Event Decured Tine Description E 20090427 16 24 58 ASS 4 hop Control Ek 2009 04 27 16 24 57 251 Reverse Control A Even tre result The system will retrieve the parameters of the relevant user group from the drive and display the parameter list 2 Inquire and Chang
46. ity is displayed Trip Information Detail information on the trip is displayed Status Information Main parameter values when the trip occurred are displayed 7 3 Result The result values of functions such as Compare are displayed 7 3 1 Inquire Result Click a result you want to inquire in the navigation window or click the result tap in the result information window to display the result Information window He Drive View 7 File Drive Configuration Help BA a e E Bs New Open Save 7 zed Report Communication DRIYE EXPLORER Fo BR E RM LZ Compare Trend Help 34 DRIVE VIEW 7 Connection a dl LS485 GA LJ ez 4L5465_01_iG54 GA 6197 EE Parameter File e E DA2008_Project Source binT EE Event Group Name Code Parameter Name DRV i 1 Cmd Frequency DRV Ey 2 Cmd Torque DRV 3 Acc Time DRV 3 4 Dec Time DRV E Cmd Source DRV 7 Freq Ref Src DRV 8 Trq Ref Src DRV 9 Control Mode DRV 10 Torque Control DRV 11 JOG Frequency DRV a 12 JOG Acc Time DRV 4 13 JOG Dec Time DRV 4 14 Motor Capacity DRV 3 15 Torque Boost DRV y 16 Fwd Boost Result Group Name Code Parameter 12 Rated Slip 14 Noload Curr 15 Rated Volt 21 Rs 22 Lsigma 23 Ls 24 Tr 25 55 Step Freg 6 40 00 56 Step Freg 7 30 00 12 ASR P Gain 1 100 0 13 ASR Gain 1 200 23 ASR SLP Gain2 50 0 63 FWD Speed Lmt 100 00 65 Speed Lmt Gain 1000 52 12 Filter 10 gt Event Trif Result A Value 0 00 0 0 20 0 30 0 F
47. l Event Trip Result The system will retrieve the parameters of the relevant group from the drive and display the parameter list 2 Inquire and Change individual parameter value E Double click the name of a parameter to inquire in the parameter list The system will retrieve the parameter values from the drive and apply them to the list and the parameter editor will be displayed Parameter Editor CON 15 ASR P Gain 2 ue Up Max 500 0 Default Value 50 0 Min 1 0 mm 4 6 LS industrial Systems Drive View 7 eo Make a change in the editor and click the Write button The changed parameters will apply to the drive and the result will appear in the status display window of the editor m j f Parameter Editor CON 15 ASR P Gain 2 60 0 rite Parameter Success 3 Description on Editor Parameter Editor Message is displayed in the combo and the window to type numbers is displayed for normal input Type a value to change within the range from the minimum value to the maximum value Up Move to the previous parameter from the currently displayed parameter in the parameter list Down Move to the next parameter from the currently displayed parameter in the parameter list Max Min Default Value The maximum minimum and default value the value set in the factory are displayed Read A parameter of the drive is retrieved and displayed Write A parameter value of the drive is wr
48. lter 10 msec 23 11 Curr x1 4 00 m 24 II Perc y1 0 00 5 8 2 2 Set up Header Function to edit texts to be displayed in the report header Report Menu Select Configuration gt Header Setting The report header edit window will appear Report Header Company LSIs Department CP Date 2009 04 27 15 24 38 User Name KilDong Hong Model Name iS Model Version 1 02 Node Name 485_6 Operation Mode Online Company name department name and user name are editable and other items are automatically entered If you click OK button the Setup is saved and the changed contents are reflected to the report LS industrial Systems 3 3 Drive View 7 5 8 2 3 Refresh Function to update the report information Report Menu Select Function gt Refresh The updated information will be displayed in a form of report 5 8 2 4 Print Function to print the report with a printer Report Menu Select File gt Print Print Setup Printer Name HF Laserjet 5200 PCL 6 w i Status Ready Type HP LaserJet 5100 PCL E Where IP_165 244 749 17 Comment Orientation Faper Size A4 Kg Portrait Source Landscape Click the OK button to print the report 3 4 LS industrial Systems Drive View 7 6 Monitor and Control Drive 6 1 Monitor Drive Screen to allow the user to monitor those drives connected with Drive View 7 in a form of lis
49. lue of Y axis will be automatically adjusted as the channel value changes If not checked the user needs to type the maximum and minimum value and the maximum and minimum value of Y axis are fixed with those values If the channel value is less than the minimum value or more than the maximum value Y axis will not change Show Grid Select to show the grid in the graph Show Label Select a Label that shows the channel name 59 Drive View 7 WT 8 Background and Text 6 0 Select a color of graph and text 8 1 3 3 Trigger Setting Trigger Ch T i E Record File Path Rte ss 100 00 l d W 2008_project source bin scope csv Edge Trigger Rising EN Captured Trigger Screen File Patn A d 2008_project source hin snapshot bmp 1 Channel Setting Display Setting Trigger Setting OT Trigger Channel To use the triggering function trigger setup shall be saved at the box 1 Only one channel is allowed for triggering 2 Trigger Level Decide the baseline value of triggering 3 Edge Trigger Select whether to save the screen either when the channel value rises higher than the triggering value Rising or when it falls lower than the triggering value Falling 4 Record File Path When recording select a file to record Selecting can be done only when recording stops During the recording you can not select since it is inactive 5 Captured Trigger Screen File Path Select a file to w
50. o 4 SY IGSA Y2 20 Detailed Node Information TA Fie Drive Configuration Help BS d AAAA w um New Open E E Communication Upload Download Compare Trend Help Reverse Reset Stop Forward DRIVE EXPLORER E F DRIVE VIEW 7 oro Connection r 3 Drive Information Run Information wig LS485 be 4_L5485_01_iG5A Comm State Normal Error o Model up o 3 pplication Parameter Group Version 22 Run Status Stop Ey DAV a Acc Time 15 4 sec Node 485_4 Dec Time 25 9 sec Drive LS485_01 i User Group Gly 6 157 W Select Application Capacity 75 pplication SR ff Parameter Group Voltage 2004 3 phase fan cooling Application Not Use iv Ey DAV Ey DAG Ey ADV KR TC Ey M2 4 User Group Parameter File CE Event ET Trip FS Result Output Frequency Not Use Event Occurred Time Description E 2009 04 27 16 01 49 485 A Stop Control EE 2009 04 27 16 01 47 485_4 Forward Control be 2009 04 27 16 01 44 485 4 Stop Control BE 2009 04 27 16 01 35 485_4 Reverse Control N event Trip Result 6 4 2 Displayed Detail Information Items 1 Drive Information Information on the connected drive is displayed Drive Information Model SVAS7 Version 1 02 Node E Capacity mu Voltage 2004 3 phase fan cooling e Model Ihe model name ot the drive model is displayed O Version The version of the drive model is displayed e Node The name of the node that consists of communic
51. o sY er eee III drel RK ey E D Y mural Upad Dopod Lempira Tre Oui Frea Hz D Arda gi dee a Dread dew arrester dew Hiei Speed dere Deere Top Z esp LS industrial Systems 4 1 Drive View 7 4 Main Screen e Click an application from the tree to display the entire diagram organization chart This chart is displayed only when there is a diagram named Main for the relevant application DRIVE EXPLORER Jj DAVE VIEW 7 Connecton w cg LS s A 4 940601 565A D A 6387 amp Aeplication bat ine Pm diw Main Speed Command 1 Dtameter Calculador 0 gt Out Speed Calculation ind qd d PID Zorte dew Parametar Gro WP User Group E Parameter Fle Event WEB PID Controller Web PID Source Select l 07 es Event Tee esp 5 Link button e Click the link button to move to the relevant diagram Main Speed Command will move to Main Speed Command diagram PIESA Seion Amh aviar is a drel DAVE EXPLORER E Qj DRIVE VIEW 7 S yl Connection Ho AL 1654 a PET a yy Applicaton Analog Qui drw are Diamatar dra MainSpaad drw Dufreg dra FIG Corto drw PID oures drw 4 RG Parameter Group Gy User Group Prametes Fla EE Event W Evez Tr het 42 ES naud Drive View 7 6 5 2 Inquire and Change Parameter Value 1 Read the entire parameter values of a diagram Double click the name of a diagr
52. played Compare Parameter Target1 Fie O Drive ic Program Files WLSIS Drive View 7Parameter Group WivS_Crane dr EJ Target2 File ODrive O Default value When selecting Drive you may select a drive associated with the communication mode Compare Parameter Targeti File O Drive ic Program Files W i St WDrive View 7WParameter Group iS Care dr ke Target2 OFile Drive O Default value ep y C y 2 2 LS industrial Systems Drive View 7 When comparing with default value select Default Click the compare button The progress bar of the main screen shows the comparison progress The result display window will show the result after completion Be D A2008 Project source NDN lemp Old Formats 7 New l dmp Fie Drive Configuration Help D RW A e B RK F EF E Z New Open Save dek Jo Report Communication Uploe o Compare Trend Help DRIVE EXPLORER 0 DRIVE VIEW 7 Group Name Code Parameter Name Value Connection DRV 3 1 Cmd Frequency 0 00 Sasi LS485 DRV 2 2 Cmd Torque 0 0 2 1 1V5 DRV 3 Acc Time 20 0 2 4 L8485_01_iG54 DRV y A Dec Time 30 0 A 6_iS DRV d E Cmd Source FieldBus E Parameter File DRV YY 7 Freq Ref Src FieldBus E D 2008_ProjectSourcetb DRV Y 8 Tra Ref Src Keypad 1 FE Event DRV 9 Control Mode V F ET Trip DRV 2 10 Torque Control No FS Result DRV Y 11 JOG Frequency 10 00 DRV Y 12 JOG Acc Time 20 0 DRV 4 13 JOG Dec Time 30 0 DRV 14 Motor Capacity 0 75kW
53. r User files have extension cus Select User File He S485 Station No 1 S i 5 Y2 50 Wser D2006 Project source Din lempi vyo Cusl cus Fie Drive Configuration Help Ea A a e B Bs F BS E RM LZ New Open Save ndo Redo Report Communication Upload Download Compare Trend Help DRIVE EXPLORER a EH DRIVE VIEW 7 Group Name Code Parameter Name Connection DIO Y 3 P3define E a LS485 DIO Ey 4 P4 define Sei 1145 DIO Ey 6 P6 define Yi Application DIO Ey 7 P7 define O Parameter Group DIO Ey 41 AX1 Define Ey DIO DIO Ey 48 ZSD Band Ey PAR DIO Ey 49 SDlevel Ey FUN DIO Ey 50 SD Band Ey CON 3 7 2ndDecSSt Ey EXT 8 2nd Dec S Ed Ey Alo 9 2nd Acc time Ey USA y 10 2nd Dec time Ey 2nd Ey E L Ey SYN WEB User Group i 5_Cus0l fy 4L5485_01_iG5A Bgl 6157 E Parameter File CE Event ET Trip ES Result Y 11 2nd Cool Mtd 2 12 2nd Enc Y 13 2nd Enc Dir 3j 14 2nd Enc Chk YY 15 2nd Enc LPF 16 2nd BaseFreq EY 11 AccDecWeb SE 2009 04 27 14 02 06 Event Trip Result lf the model is not under the same drive to which the model is intended to add the model name will appear in the message box and it will fail in opening file Drive View 7 Node Model P54 User File Model iS Lox The user file information will add under User Group and the user can refer to the parameter files registered in the user file 1 8 LS industrial Systems Dri
54. register Drive for each communication mode is described 5 3 1 Add Modbus TCP Drive Menu Select Drive gt Add gt Modbus TCP The dialog to add Modbus TCP Drive will be displayed Madone TEP emon EN Station Name TCP_001 2 Station IP EN 2 IP Range 165 nr 1 Station Name Type the drive name you want to register and control in Drive View 7 2 Station IP If you click the IP radio button when registering one drive it will activate Type IP Address assigned to the drive 3 IP Range If you click the IP Range Radio button when searching and automatically registering multiple IPs they will activate a IP address may be designated with range 5 Add The drive will be added before closing The range is automatically registered 6 Close The work to register Modbus TCP Station will end If you click the Add button after typing information the Modbus TCP Drive you type and search will be added to Drive View 7 lf you click the Close button the work to add Modbus TCP Station will end Drive View 7 TS 5 3 2 Add Modbus RTU Drive Menu Select Drive gt Add gt Modbus RTU The dialog to add Modbus RTU Drive will be displayed Modbus RT Station Station Name EN RTU O1 Station No Go Station Range O All 1 Station Name Type the drive name you want to register and control in Drive View 7 2 Station No If you click the IP Radio button when registering on
55. ring Menu Select Configuration gt Show Label Function to show or hide Label that indicates the channel name 8 1 2 11 Open Scope File Function to retrieve one of the saved scope files Graph Monitoring Menu Select File gt Open Scope File Select a file you want to open after clicking The extension of files is sco Open Scope File Look in Scope File 15 iGSA_ScopeO1 sco 5 iPSA_ScopeD1 sco S iP5A_Scope02 sco sl 57_ScopeDl sco em L lz Scopett scn Y sl 57_Scope03 sco sl W5_Scope0l sco E iv5_Scope02 sco Recent Desktop My Documents Ja My Computer a File name 57_ScopeDl sco y DD My Network Files of type Scope File sco v gt This function will be active only when monitoring stops 8 1 2 12 Save Scope File Function to save the graph currently monitored All of the setup Information of the graph will be saved Graph Monitoring Menu Select File gt Save Scope File The extension of the saved files is sco 56 Drive View 7 Save Scope File Save in O Scope File sl G54_ScopeDl sco 5 iP5A_Scope01 sco 5 iP5A_Scope02 sco S iS7_Scope01 sco sl 57_ScopeD2 sco 3 ss 57_Scope03 sco 15 iVvS_Scope01 sco Desktop 5 iv5_ScopeD2 sco My Documents 29 My Computer gt File name lis 7_Scope_01_flow v My Network Save as type Scope File sco v
56. roup Name Code Parameter Name Connection DRV 4 0 Cmd freg 0 00 Hz Sasi LS485 DRV a 61 ACC d 5 0 sec ATI IN DRV Ey 2 DEC 10 0 sec mz 2 4LS485_01_ G5A DRV 3 3 DRV Terminal 1 i 6_iS DRV Y 4 FRO Keypad 1 SE DRV Ey 5ST1 10 00 Hz e E DEFEAT DRV a 66 ST2 20 00 20 00 Hz DRV a 67 ST3 30 00 30 00 Hz DRV Ey 8 CUR 0 0 0 0 DRV y 9 RPM 0 0 DRV ai 10 DCL 0 0 0 0 DRV 5 11 USR 0 00 0 00 DRV a 12 FLT No No DRV Y 13 DRC Forward Forward DRV a 14 DRV2 Terminal 1 Temrminal 1 DRV 15 FRQ2 Keypad 1 Keypad 1 DRV Y 16 PID Ref 0 00 0 00 DRV 17 PID FBK 0 00 0 00 EU y 1 Run Prohibit None None FU 3 2 ACC Pattem Linear Linear EU y 3 DEC Pattem Linear Linear FU o 4 Stop Method Decel Stop Decel Stop iia am ewe ann ranan an Event Occurred Time Description N Event Trip s 5 7 4 2 Open Parameter File Open one of existent parameter files Menu Select File gt Parameter gt Open Parameter File When the window to select File opens select a parameter file you want to open and click the open button The extension of parameter files is dmp Look in Parameter Group sl OO Ce Pi O v5_Crane dmp v5_defualt dmp Recent Desktop My Documents My Computer File name M deu dng Y My Network Files of type iS Parameter File dmp Y The selected parameter file will be added to the tree information window 2 4 LS industrial Systems Drive View 7
57. set default value Click Install Button 485 6 Download parameters ADY RegenAvd Level Write Fail APP App Mode Write Fail Drive 485_6 Download Parameter completed Success 539 Fail 2 The parameter that fails in writing will appear The completion message will appear 6 8 LS industrial Systems Leader in Electrics amp Automation LS Industrial Systems M HEAD OFFICE LS tower Hogye dong Dongan gu Anyang si Gyeonggi do 1026 6 Korea http eng lsis biz Tel 82 2 2034 4689 4888 Fax 82 2 2034 4648 E LS Industrial Systems Tokyo Office gt gt Japan Address 16F Higashi Kan Akasaka Twin Towers 17 22 2 chome Akasaka Minato ku Tokyo 107 8470 Japan Tel 81 3 3582 9128 Fax 81 3 3582 2667 e mail jschuna Isis biz E LS Industrial Systems Dubai Rep Office gt gt UAE Address P O BOX 114216 API World Tower 303B Sheikh Zayed road Dubai UAE e mail hwyimOlsis biz Tel 971 4 3328289 Fax 971 4 3329444 E LS VINA Industrial Systems Co Ltd gt gt Vietnam Address LSIS VINA Congty che tao may dien Viet Hung Dong Anh Hanoi Vietnam e mail srjioOhn vnn vn Tel 84 4 882 0222 Fax 84 4 882 0220 E LS Industrial Systems Hanoi Office gt gt Vietnam Address Room C21 5th Floor Horison Hotel 40 Cat Linh Hanoi Vietnam Tel 84 4 736 6270 1 Fax 84 4 736 6269 E Dalian LS Industrial Systems co Ltd gt gt China Address No 15 Liaohexi 3 Road economic and technical development
58. t The monitoring status will appear regularly communicating with those drives and retrieving those monitored parameters 1 Display ltems Protocol One of three communication modes Modbus TCP Modbus RTU LS485 Communication Mode is displayed Station Address IP In case of TCP IP and in case of RTU or LS485 station No is displayed Drive Name The Drive Name designated by the user is displayed Drive Model Its drive model is displayed Capacity lts capacity is displayed Voltage Its voltage is displayed Run Status The current run status is displayed Trip Information The current trip status is displayed 2 Monitor the entire nodes To monitor the entire drives connected with Drive View 7 regardless of their communication mode click Connection at the top of the tree information window He Drive View 7 Connection File Drive Configuration Help D fA q Aa PE RR BP RA EB az New Open aport Communication Compare Trend Help DRIVE EXPLORER a 58 DRIVE VIEW 7 Protocol Station Address IP Drive Name Drive Model Capacity Voltage Run Status a Connection oi LS485 4 LS485_01 G5A 75W 200V 3ph Stop E ag LSA ig LS485 6 iS 800 W 200V 3 ph Trip So 415485_01_1G54 Application BS Parameter Group Ey DAV Ey FUI Ey FU2 Ey 1 0 ig User Group dd 6_iS Application BS Parameter Group y BAS ma oO lt Event Occurred Time Description E 2009 04 27 16 01 4
59. t Efficiency Inertia Rate AC Input Volt 8 2 2 Step by step Setup Parameters are setup through 10 Wizard steps except installation step To move between steps click the relevant step button or click the previous or next button Value Unit 0 75kW 60Hz 4 40 rpm 3 6 A 16A DV 72 0 220 V Steps and parameter types of each step may have different items according to models LS industrial Systems 6 1 Drive View 7 na _ 8 2 2 1 Motor amp Control Setup main parameters that belong to Motor amp Control 1 Motor Control a Control Mode Sensorless i EN a Torque Control Ces No Parameter Default Max Min Value Unit Motor Capacity D ZK 590 0 kW 0 2 kW 075k W 60 50 Hz Sel 60Hz 50Hz DH 60Hz Pole Number 4 43 2 4 Rated Slip 40 3000 0 4 pm Rated Cum 3 6 200 0 10 36 A Noload Curr 1 6 200 0 0 5 1 64 Rated Vote Efficiency Ta 100 70 Y Inertia Rate 0 8 0 0 AC Input Volt 220 480 0 220 V Torque Control becomes inactive when the control mode is V F V F PG or Slip Click the setup value column in the list to edit each parameter The next step is changed to Torque or Speed depending on Yes or No from Setup Torque Control 8 2 2 2 Speed amp Torque 2 5peed amp Torque Speed Parameter Default Max Min Value Unit Cmd Frequency 0 00 600 00 0 00 0 00 Hz Freg Ref Sre Keypad 1 PLC Keypad 1 Keypad 1 Base Freg 60 00 400 00 30 00 60 00 Hz Start Freg 0 50 10 00 0 01 0 50 Hz Ma
60. t FOT Frequency 30 00 600 00 0 00 30 00 Hz FDT Band 10 00 600 00 0 00 10 00 Hz Set up a parameter that conforms to Digital Output 8 2 2 8 V1 Analog Input 8 V1 Analog Input Bipolar LOV 10V Input Parameter Default Max Min Value Unit VI Filter 10 10000 0 10 msec VI Volt x7 0 00 10 00 0 00 0 00 V VI Percy 0 00 100 00 0 00 0 00 V1 Volt x2 10 00 10 00 0 00 10 00 V V1 Pere y2 100 00 100 00 0 00 100 00 VI Inverting Ho Yes Ho Ho V1 Quantizing 0 04 10 00 0 04 0 04 Set up a parameter that conforms to V1 Analog Input 65 Drive View 7 66 8 2 2 9 D Analog Input Set up a parameter that conforms to 11 Analog Input 9 11 Analog Input Parameter 11 Filter 11 Cur x1 11 Pere wi 11 Cur x 1 Pere ye 11 Inverting Default Max Min 10000 0 20 00 0 00 100 00 0 00 20 00 0 00 100 00 0 00 Yes No 10 00 0 04 O 20mA Input Value 10 4 00 0 00 20 00 100 00 lt H 0 04 Unit msec m m D G de d to A 11 Quantizing IM 8 2 2 10 Analog Output 10 Analog Output AO1 Mode Parameter A01 Gain AQ Bias AQ Filter AO Const AQ Mode Parameter AQ Gain AQ Bias AQ Filter Max Min AO Const Frequency Frequency Default 100 0 0 0 0 0 Default 100 0 0 0 0 0 Max Min 1000 0 100 0 O 10V Value Unit 100 0 0 0 5 msec 0 0 1000 0
61. t to inquire the entire parameters double click Parameter Group Ef S485 Station No 6 S iS7 1 02 CON NA File Drive Configuration Help PS SS A AP SE SS S fF SS m amp ma New Open Save Undo Redo Report Communication Upload Download Compare Trend Help Reverse Reset Stop Forward DRIVE EXPLORER E dl DRIVE VIEW 7 Connection Y 4 Canier Freq Gai LS485 Ey 5 PWM Mode a 2 4_LS485_01_iG5A Ey 9 PreExTime Ge 6 157 Ey 10 Flux Force a Application Ey 11 Hold Time AnalogOut drw Ey 12 ASRP Gain 1 Break drw ERE Diameter drw Ey 15 ASR P Gain 2 MainSpeed drw Ey 16 ASR Gain 2 OutFreq drw Ey 18 Gain Sw Freq PID Control drw Ey 19 Gain Sw Delay PID Source dra Ey 20 SL2G View Sel Ey 21 ASR SLP Gain1 Ey 22 ASR SL Gain1 Ey 23 ASR SLP Gain2 Ey 24 ASR SL Gain2 Ey 26 Observer Gain1 Ey 27 Observer Gain2 Ey 28 Observer Gain3 Ey 29 S Est P Gain 1 Ey 30 S Est Gain 1 3 Ey 31 S Est P Gain 2 Es APO Ey 32 S Est Gain 2 Ey PRT Ey 34 SL2OVM Perc Ey M2 Ey 45 PG P Gain W User Group Ey 46 PG Gain Parameter File Ey 47 PG Slip Max CE Event Ey 51 ASR Ref LPF ET Trip Ey 52 Torque Out LPF E5 Result EJ 53 Torque Lmt Sre EY 54 FWD Trq Lmt Ey 55 FWD Trq Lmt Ey 56 REV Trq Lmt Ey 57 REV Trq Lmt E 58 Trg Bias Src E 59 Torque Bias E 60 Trg BiasFF Ey 62 Speed Lmt Src E 63 FWD Speed Lmt Event Occurred Time Description j EE 2009 04 27 16 24 58 485_4 Stop Control be 2009 04 27 16 24 57 485_4 Reverse Contro
62. t value is shown This value is the original value without conducting Offset and Val Div lf there is any problem in the communication a message of communication error will appear Offset Offset applies to the current Offset value The graph shows the value to which set applies Val Div Val Div applies to the current value The graph shows the value to which Val Div applies 8 1 3 2 Display Setting Show Grid 4 M Graph 1 l Individual A Y axis Auto Scaling Show Label raph Coun bh Graph 1 ai Y axis Min Background Text a gt bh Graph 2 Y axis Max Channel Setting Display Setting Trigger Setting 1 Individual Graph Count Function to show channels with individual graphs After checking Individual Graph Count and type the number of graphs 1 4 click the change button to show the selected number of monitoring graphs Basically graph 1 is assigned to all channels If Individual Graph Count is not checked only one graph will be shown and all channels are positioned in that graph Select Graph After checking Individual Graph Count you may select a location of each channel The default value is designated to the location of Graph 1 Line Color Select line color of the channel Thickness Select line thickness of the channel Y axis Auto Scaling If Y axis Auto Scaling is checked the maximum and minimum va
63. tart amp Stop When selecting DC Start in the Start Mode Dc Start Time will appear When selecting DC Brake in the Stop Mode Dc Block Time Dc Brake Time and Dc Brake Freq Parameter will appear 63 Drive View 7 QQ 8 2 2 5 Digital Input 5 Digital Input P1 Define Forward Run P2 Define Reverse Run P3 Define Emergency Stop P4 Define Reset PS Define JO D Define 5peed L P Define Speed M PS Define Speed H Out Freq _ Setup a parameter that conforms to Digital Input 8 2 2 6 Multi Step Speed 6 Multi Step Speed 40 0 UU AA Parameter Default Max Min Value Unit Step Freg 1 10 00 600 00 0 00 10 00 Hz Step Freq A 20 00 600 00 0 00 20 00 Hz Step Freg 3 30 00 600 00 0 00 30 00 Hz Step Freq 4 40 00 600 00 0 00 40 00 Hz Step Freq 5 50 00 600 00 0 00 50 00 Hz Step Freg 6 60 00 600 00 0 00 60 00 Hz Step Freg 60 00 600 00 0 00 60 00 Hz Step Freq 8 55 00 600 00 0 00 55 00 Hz Step Freg 9 50 00 600 00 0 00 50 00 Hz Step Freg 10 45 00 600 00 0 00 45 00 Hz Step Freg 11 40 00 600 00 0 00 40 00 Hz Step Freg 12 35 00 600 00 0 00 35 00 Hz Step Freg 13 25 00 600 00 0 00 25 00 Hz Step Feq 14 15 00 600 00 0 00 15 00 Hz Step Freg 15 5 00 600 00 0 00 5 00 Hz Setup a parameter that conforms to Multi Step Speed 64 Drive View 7 8 2 2 7 Digital Output 7 Digital Output Relay 1 Trip Relay 2 Run Q1 Define FDT 1 Parameter Default Max Min Value Uni
64. up Ey DIO Ey PAR Ey FUN Ey CON Ey EXT Ey Alo Ey USA Ey 2nd Ey E L Ey SYN g User Group Y NewCustom_t ZS ETE Ab IS E Parameter File Trip FE Event SH Occurred Time Drive Name fe 2009 04 27 14 02 06 Event Trip A Result L Help Drive Model Capacity Voltage iV5 5 5 KW 200V 3 ph Stop G5A 75W 200V 3 ph Stop iS7 800 W 200V 3 ph Trip Protocol Station No IP Model Capacity 485 6 iS7 800 W Anew group is added under User Group a submenu of the selected drive Trip Option Trip 1 LS industrial Systems 1 5 Drive View 7 1 Add Parameter Select a parameter to add to User Group Drag and drop the selected parameter to the user file ES S485 Station No 1 SY 1Y45 Y2 50 DIO Fie Drive Configuration Help H A A e B BS ER ER New Open Save Undo Redo Report Communication Upload Download Compare Tr DRIVE EXPLORER a 38 DRIVE VIEW 7 Connection Sy LS485 2 P2 define Not Used SA 1145 Se 3 P3defne Nt sed o Application 4 P4define TE E 17 S 5848 Parameter Group 5 P5de ne E E S O E Ey DIO fe 6 PGdefine E E Ey PAR Sl 7 P7 define Es FUN Terminal LPF E CON AX1 Define Ey EXT 42 AX2 Define Not Used A A E Ey alo 43 OC1 Define Not Used CA nee msec Ey USA 46 Relay mode b011 Ey 2nd 47 ZSD level wh gt E o 3 oo of On o ME oof of s 3 Ey Eat ZSD Band Ey SYN SD level Ey WEB Ee
65. ve View 7 5 6 3 Save User File Menu Select File gt User gt Save User File Drive View 7 iia peice lf there is any change in the current user file the screen to ask the user whether to save the change Click the cancel button not to save the change Click the OK button to display the screen to type the file name Save User Group File Save in User Group Ej Project_01 cus KE Project_02 cus E Project_03 cus KE Project_04 cus KE Test_O1 cus File name Us D Y D My Network Dave as type User Group File cus v Select a path and type a file name Then click the save button The user group file will be saved in the selected path 5 6 4 Close User File Select a user file you want to close Menu Select File gt User gt Close User File 1 In case of new user group or changed one The screen to ask you whether to save the file or not Drive View 7 New User File CoM Program Files L515 Drive View Z WW ler Group Wier DI os Do you want to save the File If you select OK the screen to ask you about a path and a file name will appear as in the saving process The file will be saved in the same way as in saving a user group and the user group will close after saving Select Cancel to close the user group without saving 2 In case of user group without any change lt will close without asking whether to save it or not LS in
66. x Freq 60 00 600 00 60 00 Hz Torque Boost Manual EA Manual Fwd Boost 20 15 0 0 0 2 0 Rev Boost 20 15 0 0 0 2 0 lt is possible to set up Fwd Boost and Rev Boost when Torque Boost is in manual 2 5peed amp Torque Torque Parameter Default Max Min Value Unit Cmd Torque 0 0 180 0 180 0 0 0 Trg Ref Sre Keypad 1 PLC Keypad 1 Keypad 1 Torque Lmt Sre Keypad 1 Binary Type Keypad 1 Keypad 1 Speed Lmt Sre Keypad 1 PLE Keypad 1 Keypad 1 FWD Speed Lmt 60 00 600 00 0 00 60 00 Hz REV Speed Lmt 60 00 600 00 0 00 60 00 Hz Speed Lmt Gain AM 5000 100 500 e Drive View 7 8 2 2 3 Time 3 Xcel Time Ramp T Mode Max Freg E Acc S Start 1 100 AccSEnd 1 100 DecSStart i 100 Der S End 1 100 40 e Freq Max Taget Time Acc Time Dec Time 6 po ls Acc Time 0 0 600 0sec Dec Time 0 0 500 0sec 20 0 30 0 Acc Pattern Dec Pattern save y save 19 Parameters related to time will appear along with a graph The graph will change according to the parameter values selected in the combo and the time range can be changed in the edit window 8 2 2 4 Start amp Stop 4 Start 4 Stop Parameter Default Max Min Value Unit Cmd Source Ru Pac 1 PLE Keypad Fe Rx Stat Mode Acc Dic Start Ace Acc Stop Mode Dec Power Braking Dec Dec Run Prevent None Reverse Prev None None Power on Run Ho Yes Ho Ho Dc Inj Level Di A00 D DI y Set up a parameter that conforms to S
67. x Rx 1 Keypad 1 Keypad 1 V F Se 10 00 20 0 30 0 0 75kW Manual 2 0 Default Unit 0 00 Hz 0 0 20 0 sec 30 0 sec Eu Rx 1 Keypad 1 Keypad 1 V F RUE AS 10 00 Hz 20 0 sec 30 0 sec 0 75kW Manual 20 a Default Val Unit LS industrial Systems 5 3 Drive View 7 a 8 Additional Functions 8 1 Graph Monitoring Trend The graph monitoring function which allows the user to monitor parameters in a form of graph is described Through this function the user can monitor up to four channels One graph may display four channels at the same time or each graph may display one channel respectively Up to four graphs are available at a time 8 1 1 Start Trend Drive View 7 Menu Select Drive gt Trend If there is any previous monitoring information start monitoring with that information Monitoring up to four channels is possible Fie Function Configuration E RH E lb SS E Eu S Analog Output 1 me PID Reference Analog Output 1 Hey Neg Torque Limit Set UE WIL UU 00 00 30 00 10 010 UU WU 00 10 0101 AAA AAA AU A e UL AA L AAA UL HN Recording Elapsed Time Record Counter X axis Time Monitoring Time Record Time Monitoring Channel Data Offset Value Division Es CHi 4856 La Analog Output 1 i i M CH2 2856 iw PID Reference Ed i CH3 485 4 Analog Output 1 P 0 wel la FP CHA 435 1 ow Rev Neg Torque Limit Set Display Setting Trigger Setting
68. yping information the LS485 Drive you type and search will be added to Drive View 7 If you click the Close button the work to add LS485 Station will end 5 4 Delete Drive Delete a drive among those registered in Drive View 7 Select a drive to delete click the drive from the associated information window or the search window Menu Select Drive gt Delete The dialog to confirm deleting the selected drive will appear Drive View TYPE L54855 j V No 6 Do vou want bo delete the station OK The selected drive will be deleted Cancel The work to delete will be cancelled When you select OK the selected drive will be deleted The deleted screen will appear Drive View 7 TTS 5 5 Other setup 5 5 1 Set up Language Drive View 7 basically supports English and Korean At the initial running after installation the dialog to select language will appear to allow the user to select language The user is allowed to change language anytime during the operation Menu Select Configuration gt Language The dialog to select language will appear English HR 1 Select Language The currently selected and operated language is displayed The combo list shows available languages Select a language you want to replace the current language with The combo language file list is displayed only if the system has any language file to support the list 2 OK The selected language will b