1.    HTL level  TTL level    2 digital inputs   lt  2 4 V OFF   gt  10 V ON  max  30 VDC   lt  1 9 V OFF   gt  4 6 VON    Input resistance R   5 kO    0 4 20 mA   burden  lt  500Q  0 10 VDC   burden 2 10 KQ  16 Bit  24 VDC   10  galv  isolated  max  4 VA     Analog output    Power pack    EEPROM  2 100 years at 25  C    Memory    Data life    Ambient conditions  0   50  C   20   80  C    Working temperature  Storing temperature    Climatic density relative humidity 0 80  on years average without dew    Conformity to directive 2004 108 EG  Safety standard EN 61010  EN 60664 1    20       9  Safety advices    9  Safety advices    Please read the following safety advice and the assembly chapter 7 before installation and keep it for  future reference     Proper use  The M3 7G device is designed for the evaluation and display of sensor signals     Attention  Careless use or improper operation can result in  personal injury and or cause damage to the equipment     Control of the device    The panel meters are checked before dispatch and sent out in perfect condition  Should there be any  visible damage  we recommend close examination of the packaging  Please inform the supplier  immediately of any damage     Installation    The M3 7G device must be installed by a suitably qualified specialist  e g  with a qualification in  industrial electronics      Notes on installation    e There must be no magnetic or electric fields in the vicinity of the device  e g  due to transformers   mobil
2.   3  Click the fixing elements back into place and tighten the clamping screws by hand  Then use  a screwdriver to tighten them another half a turn     CAUTION  The torque should not exceed 0 1 Nm     The dimension symbols can be exchanged before installation via a channel on the side     3  Electrical connections    3  Electrical connections    Type M3 7GR5A 00X0 770BD supply of 24 VDC galv  isolated    OOOO       TTL  Namur       gt   E 3  z    J  E E   I    Digital input 1 Digital input 2    HTL  15 30 V       0 4 20 mA   0 10 VDC    Analog output    M3 devices with frequency input   pulse input    Control feeler     with external voltage source         feeler   feeler    Advice  Mind the selected input level INLE       Control lock for setpoint value       Key switch with external voltage source    Advice  Mind the selected input level  MLEV     3  Electrical connections    4  Function and operation description  4  Function and operation description    Operation  The operation is divided into three different levels     Menu level  delivery status    This level is for the standard settings of the device  Only menu items which are sufficent to set the  device into operation are displayed  To get into the professional level  run through the menu level  and parameterise    PROF under menu item RUN     Menu group level  complete function volume    Suited for complex applications as e g  linkage of alarms  setpoint treatment  totaliser function etc  In  this level function grou
3.  16    5  Setting up the device    5 4 5  Alarm parameters    Menu group level    AL l      P       Menu level  Parameterisation level    Threshold values   limit values  L      Default  2000    L di  i  P  0    p    p    g e p se              v  a  For both limit values  two different values can be parameterized  With this  the parameters for  each limit value are called up one after another     Hysteresis for limit values   9     Default  00000    P  m P  o P  io e  g e  ae    HY     iv  a  A hysteresis function exists for all limit values  it reacts according to the settings  threshold  exceedance   threshold undercut               Li       Function if display falls below   exceeds limit value  FU     Default  HIGH   Fu  P  HIGHS Louw   f     v   Al The limit value undercut can be selected with LOUU  LOW   lower limit value  and limit value  exceedance can be selected with HIGH  HIGH   upper limit value   If e g  limit value 1 is on a  switching threshold of 100 and occupied with function HIGH  the alarm will be activated when  reaching the threshold  If the limit value is allocated to LOU  an alarm will be activated by  undercut of the threshold    Switching on delay  TON I   Default  000  L l    CANT t  P  rm  P  r   lA   P   L L  v   For limit value 1 one can preset a delayed switching on of 0 100 seconds     17       6  Reset to default values    Menu level Parameterisation level    Switching off delay  TOF I   Default  000    o e ge e       For limit value 1 one can p
4.  4 4  Analog output parameters       Menu group level       fra     Oue     P         Menu level Parameterisation level    Selection analog output  OUT RA   Default  0 10    me m  Al  LI co   P    Two output signals are available  0 10 VDC and 0 20 mA  they can be selected with  A   Y   and confirmed with  P   A limitation of the output range can be done via OUT EN and QUT OF to e g   4 20 mA     Setting up the final output value  QUT EN   Default  10 000    gP g Pp   ge gee       The final output value is adjusted from the smallest to the highest digit with  A   Y  and  confirmed digit per digit with  P   After the last digit the display changes back into menu level     Depending on the adjusted output signal OUT RA the value corresponds to a voltage of 0   10 V  or a current of 0   20 mA and is reached  when the final setpoint END is reached as setpoint     Setting up the initial analog output value  OUT OF   Default  00 000    g P g Pg P gP gee    The initial analog output value is adjusted from the smallest to the highest digit with  A   Y   and confirmed digit per digit with  P   After the last digit the display changes back into menu  level  Depending on the adjusted output signal QUT RA the value corresponds to a voltage of  0   10 V or a current of 0   20 mA and is reached  when the initial setpoint OFFS is reached as  setpoint        Back to menu group level  RET     With  P  the selection is confirmed and the device changes into menu group level      OUT            
5.  5 4 4  Analog output parameter    OUT     Analog output functions  5 4 5  Alarm parameter   AL1   ALY  Activator and dependencies of the alarms  Reset to factory settings  Reset of the parameter to the factory default settings  Alarms   Relays  Function principle of the switching outputs  Technical data  Safety advices    Error elimination       on oO ON O    O N       _     _    11  11    14    14    16    17    18    19    20    21  22    1  Brief description  1  Brief description  Setpoint function    A setpoint generator enables the user to adjust operating parameters of a machine  like e g  an  oven temperature  rotational speed or filling weight  in the most easiest way and relays it via the  integrated outputs to a superior control  Thereby the production engineer can determine the  adjustment range and thus guarantee a safe operation  This makes the setpoint generator an  ideal device for simple control with a few parameters or for a more complex regulation  where a  simple relation between setpoint value and the machine behavior that needs to be controlled is  not possible  e g  the filling weight of an ampoule filling system     For the setpoint generator the display value is changed manually by the user  depending on the  adjustment TYPE via the front keys or via the digital inputs  The possible adjustment range is  definable via the parameters END and OFFS  An output quantity OUT RA with the output range OUT EN  to OUT OF is allocated to them  By changing the set
6.  Back to menu group level  RET     With  P  the selection is confirmed and the device changes into menu group level      FLT          User code U CODE   Default  0000    gegeasee    Via this code reduced sets of parameters can be released  A change of the U CODE can only be  done via the correct input of the A CODE  master code      Master code  A CODE   Default  1234       By entering A CODE the device will be unlocked and all parameters are released     14    5  Setting up the device    Menu level Parameterisation level    Release lock analog output parameters  QUT LE   Default  ALL    no   En 0 Use    Analog output parameters can be locked or released for the user      At EN OF the initial or final value can be changed in operation mode      At OUT EO the output signal can be changed from e g  0 20 mA to 4 20 mA or 0 10 VDC     At ALL all analog output parameters are released      At NG all analog output parameters are locked    Release lock alarm parameters  AL LEU    Default  ALL        ALL rw E    This parameter describes the user release user lock of the alarm      LIMIT  here only the range of value of the threshold values 1 4 can be changed     ALRA L  here the range of value and the alarm trigger can be changed      ALL  all alarm parameters are released      NO  all alarm parameters are locked     Back to menu group level  RET     With  P  the selection is confirmed and the device changes into menu group level      COD            15    5  Setting up the device    5
7.  Menu group  Menu level  B  i ay  P  S w or   P   P     Parameter  a  v    Menu level  level                       Input interruption   gt 10s    Input interruption   gt 10s    v      P     Parameter  aw    wen  DHO    Explanation     P  Take over         v  Breakoff by simultaneously pushing of the navigation keys       Value selection       v  Value selection        4 1 Parameterisation software PM TOOL     Part of the PM TOOL are the software on CD and an USB cable with device adapter  The connection is  done via a 4 pole micromatch plug on the back side of the device  to the PC side the connection happens  via an USB plug     System requirements  PC incl  USB interface  Software  Windows XP  Windows VISTA    With this tool the device configuration can be generated  omitted and safed on the PC  The parameters can  be changed via the easy to handle program surface  whereat the operating mode and the possible selection  options can be preset by the program     5  Setting up the device  5  Setting up the device    5 1  Switching on    Once the installation is complete  you can start the device by applying the voltage supply  Before  check once  again that all electrical connections are correct     Starting sequence    For 1 second during the switching on process  the segment test  8 8 8 8 8  is displayed followed by an indication  of the software type and  after that  also for 1 second the software version  After the starting sequence  the  device switches to operation displa
8.  be selected  by  A   Y  and confirmed with  P   With L SAVE the last effective setting is taken over as  setpoint during switching on  At L STAR the defined initial value START is loaded     Setting the active input level   N LEV   Default  HIGH    Fada 2 H IGH a E    The active input level can be adjusted to LOW or HIGH with  A   Y   With  P  the selection is  confirmed and the display changes back into menu level  This is a very important setting  as it  is used for all operation types TYPE     Setting the code for the adjustment lock  5 CODE   Default  0000    pe gageEg aa    The code for the adjustment lock is adjusted from the smallest to the highest digit with  A   Y   and confirmed digit per digit with  P   After the last digit the display changes back into menu  level  If the S CODE is set on a value unequal 0000  the code lock is activated for TYPE  F TAST and  FINPU  This means at each adjustment attempt the releasing code S CODE is recalled  For TYPE   settings E TAST the enable code S CODE has no meaning        Back to menu group level  RET        With  P  the selection is confirmed and the device changes into menu group level     INP       13    5  Setting up the device    5 4 2  General device parameters    Menu group level    Menu level Parameterisation level    Display flashing  FLASH   Default  NO    A display flashing can be added as additional alarm function either to single or to a combination  of off limit condition  With NO  no flashing is allocated    
9.  key lock LOC  or the  menu group level PROF with the navigation keys  A   Y   Confirm the selection with  P   After  this  the display confirms the settings with      and automatically switches to operating  mode  If LOC was selected  the keyboard is locked  To get back into the menu level  press  P   for 3 seconds in operating mode  Now enter the CODE  works setting 1234  that appears using   A   Y  plus  P  to unlock the keyboard  FAIL appears if the input is wrong     To parameterise further functions  PROF needs to be set  The device confirms this setting with       and changes automatically into operation mode  By pressing  P  for approx  3 seconds  in operation mode  the first menu group INP is shown in the display and thus confirms the  change into the extended parameterisation  It stays as long activated as ULOC is entered in  menu group RUN  thus the display is set back in standard parameterisation again        5 4  Extended parameterisation  professional operation level     5 4 1  Signal input parameters    Menu group level     in P  o P           Menu level  Parameterisation level    Selection of the adjustment type for the setpoint   default value  TYPE   Default  F TAST          a   w P    With F TAST the setpoint is adjusted by  A   Y   furthermore the adjustment can be locked via  the external input 1  At F INPU there is a direct selective input of the setpoint via  P   A   Y   For  the adjustment  A  or  V  needs to be pressed first  Via input 1 the adjustmen
10.  the smallest to the oo digit with  A   Y  and confirm each  digit with  P   A minus sign can only be parameterized on the leftmost digit  After the last digit  the display switches back to the menu level  The value that is set here  can later on not be  undercut while adjusting the setpoint     Setting up the adjustment initial value  START   Default  0    pP p Ege gE ger       The initial value  which is loaded by start or pushing  A   V  at the same time  is adjusted from  the smallest to the highest digit with  A   Y  and confirmed digit per digit with  P   A minus sign  can only be para meterized on the leftmost digit  After the last digit the display changes back  into menu level        5  Setting up the device       Menu level Parameterisation level    Setting up the increments  STEP   Default  7    joglighighlgae    The increments for the adjustment types F TAST and E TAST are adjusted from the smallest to the  highest digit with  A   Y  and confirmed digit per digit with  P   After the last digit the display  changes back into menu level  Per keystroke the setpoint is changed by the increment  which  can be selected from 1   99999        Maximum possible change acceleration  SPEED   Default  PACE      PACE      PACE    PACEJ   PACEY    EP     Via SPEED the maximum possible change accleration of the setpoint in permanent activation of  up or down can be set  At PRCE 1 no multiplication of the increment takes place  For each other  pace step the maximum speed multiplie
11. User manual M3    Setpoint generator 0   10 V  0   20 mA       Device performance     e red display of  19999   99999 digits  optional  green  orange  blue    e minimal installation depth  90 mm without plug in terminal   e definable adjustment for the setpoint   e configurable output area between 0   10 V or 0   20 mA   e adjustable increments per keystroke   e display flashing at limit exceedance   limit undercut   e digital inputs for key switch or external adjusting keys     navigation keys for a fast query of a default value   e configurable code as adjustment protection for the setpoint   e different operation options for the adjustment of the setpoint   e optional starting performance with last adjustment value or default value    optional speed levels for the adjustment of the setpoint   e quick reaction during adjustment of the setpoint value  Ramp function     programming lock via access code     protection class IP65 at the front     plug in srew terminal      accessories  PC based configuration kit PM TOOL with CD  amp  USB adapter for devices  without keypad and for a simple adjustment of standard device    M3_7GGB pdf update  04 02 2014 48x24       Identification    STANDARD TYPES ORDER NUMBER    Setpoint generator  Housing size  48x24 mm M3 7GR5A 00X0 770BD    iM 3  7 G R 5 A  0 0  x 0   7 7 0  B D    Basic type M line Dimension   D  physical unit  Installation depth    109 mm  with plug in terminal Version     Ble    Switchpoints   0  no switchpoints       Hou
12. ck is activated for TYPE  F TAST and F INPU   This means at each adjustment attempt the enable code S CQDE is recalled  For TYPE settings  ETAST the enable code 5 C0DE has no meaning        5  Setting up the device    Menu level Parameterisation level    Selection of analog output  QUT RA   Default  0 10    mi  Hubr A    Two output signals are available  0 10 VDC and 0 20 mA  They can be selected with  A   Y   and are confirmed digit by digit with  P   The output area can be limited via OUT EN and OUT OF to  e g  4 20 mA     Setting up the output final value  OUT EN   Default  10 000    gP aP gP gegee    The output final value is adjusted from the smallest digit to the highest digit with  A   Y  and  digit by digit confirmed with  P   After the last digit the display changes back into menu level   Depending on the output signal OUT RA  the value relates to a voltage between 0   10 V ora  current between 0   20 mA and is reached  if the adjustment final value END is reached as  setpoint        Setting up the initial value of the analog output  QUT OF   Default  00 000    gP a Pg Pg Pger       The output initial value is adjusted from the smallest digit to the highest digit with  A   Y  and  confirmed digit by digit with  P   After the last digit the device changes back into menu level   Depending on the output signal OUT RA  the value relates to a voltage between 0   10 V ora  current between 0   20 mA and is reached  if the adjustment initial value OFFS is reached as  setpoin
13. e ae eet eta eae  8    5 Vv A   F 18  Off z Display  Hysterisis  kt  Aarme Quiescent current  By quiescent current the alarm S1 S4 is on  below the threshold and switched off on reaching  Threshold the threshold   Orit  e aan setae ose re eres ce    r L  3 A Vi  Ss   3  Ss    Off   Display  Hysterisis  SF  input Switching on delay  The switching on delay is activated via an alarm  10 and e g  switched 10 seconds after reaching the  Switching threshold   switching threshold  a short term exceedance of  0 the switching value does not cause an alarm   5 Time s  respectively does not cause a switching  operation of the relay  The switching off delay  On Alarm switching on delay 10 s    operates in the same way  keeps the alarm   the  relay switched longer for the parametrised time     Time s        19    8  Technical data    8  Technical data    48x24x90 mm  BxHxD    48x24x109 mm  BxHxD  incl  plug in terminal  Panel cut out 45 0   6 x 22 2703 mm  Wall thickness up to 5 mm   screw elements   PC polycarbonate  black  UL94V 0  EPDM  65 Shore  black    standard IP65  front   IPOO  back side     Fixing   Material  Sealing material  Protection class  Weight approx  200 g    Connection    plug in terminal  wire cross section up to 2 5 mm     Display   Digit height 10mm  Segment colour red  optional green  yellow or blue   Range of display  19999 to 99999  Setpoints one LED per setpoint  Overflow    Underflow    horizontal bars at the top    horizontal bars at the bottom    Transmitter 
14. e phones or electrostatic discharge     e The fuse rating of the supply voltage should not exceed a value of 6A N B  fuse     e Do not install inductive consumers  relays  solenoid valves etc   near the device and suppress  any interference with the aid of RC spark extinguishing combinations or free wheeling diodes     e Keep input  output and supply lines separate from one another and do not lay them parallel with  each other  Position    go    and    return lines    next to one another  Where possible use twisted pair   This way  best measuring results can be received     e Screen off and twist sensor lines  Do not lay current carrying lines in the vicinity  Connect the  screening on one side on a suitable potential equaliser  normally signal ground      e The device is not suitable for installation in areas with a risk of explosion     e Any electrical connection deviating from the connection diagram can endanger human life and or  can destroy the equipment     e The terminal area of the device is part of the service  Here  electrostatic discharge needs to be  avoided  Attention  High voltages can cause dangerous body currents     e Galvanic isolated potentials within one complex need to be placed on an appropriate point  normally  earth or machines ground   So  a lower disturbance sensibility against impacted energy can be  reached and dangerous potentials  that can occur on long lines or due to faulty wiring  can be  avoided     24    10  Error elimination    10  Error e
15. limination    1     The device shows  LOC  at the attempt     The adjustment lock for the setpoint is active   of change  please check if there is a key switch    LOC  e The active input signal iN LEV has to be adjusted  to HIGH instead of LOW or vice versa     By the code recall for the setpoint e At an unexpected code recall  S CODE needs to  appears FAIL or there is an unexpected be set on a value unequal 8000  Check the  code recall  parametrisation and set back the parameter     CODE    If FAIL appears after entering the code  check  FAIL the S CODE in the parameterisation     The word  HELP  lights up in the e The unit has found an error in the configuration   7 segment display  memory  Perform a reset on the default values  and re configure the unit according to your  application     4    The display does not change back to e Programming lock is activated  parametrisation after pressing  P   e Enter correct code    5     ERRT lights up in the 7 segment e Please contact the manufacturer if errors of this  display kind occur     The device does not react as    If you are not sure if the device has been   expected  parameterised before  then follow the steps as  written in chapter 6 and set it back to its  delivery status        M3_7GGB pdf 25 update  04 02 2014    
16. point in the display  the initial value is linear  and carried isochronous  The following values result from a adjustment range of the setpoint from  0   2000 and an accordingly selected output range from 4   20 mA     4mA 0  12 mA   1000  20 mA   2000    Additionally alarms can be used to warn the user about critical settings  To secure the favoured  setpoint against accidental adjustment  a releasing code S COBE can be activated or an electric  key switch can be provided  If an external key switch is used via digital input 1  then the device  shows a    L f    in the display by any attempt of adjustment via the keys  A   Y     By operating the setpoint via the front keys  a default value initial value START can be recalled via  the navigation keys  A   Y   It can be used for one system as emergency switch  too    This initial value is loaded in the basic setting during system start and displayed  If L STAR was  selected instead of L SAVE as reset behaviour RESET  the device loads up the last adjusted effective  setpoint  The latter is safed approx  1 minute after each change of the setpoint    The two excisting digital inputs react depending on the setting of IN LEV to a HIGH  or a LOU  signal     2  Assembly    2  Assembly    Please read the Safety advice on page 21 before installation and keep this user manual for future  reference        Gap for physical dimension    1  After removing the fixing elements  insert the device   Check the seal to make sure it fits securely  
17. ps which allow an extended parameterisation of the standard settings are  availabe  To leave the menu group level  run through this level and parameterise    ULOG  under menu  item RUN     Parameterisation level    Parameter deposited in the menu item can here be parameterised  Functions  that can be changed  or adjusted  are always signalised by a flashing of the display  Settings that are made in the  parameterisation level are confirmed with  P  and thus safed  All adjustments are safed  automatically by the device and it changes into operating mode  if no further key operation is done  within the next 10 seconds     Change to parameterisation level and deposited values   Menu level Keys for up and down navigation in the menu level   iv  Change into operation mode by pushing both navigation keys  at the same time     To confirm the changes made at the parameterization level     Parameterisation Adjustment of the value   the setting     Change into menu level or stop of the value input  by pushing   a   v  both navigation keys at the same time   Change to menu level  Menu group level Keys for up and down navigation in the menu group level      A   v  Change into operation mode or return into menu level  by  pushing both navigation keys at the same time        4  Function and operation description    Function chart     Standard parameterisation Extended parameterisation   Flat operation level   Professional operation level     3  P    X aly  i  run    pro     P              
18. reset a delayed switching off of 0 100 seconds     Back to menu group level  RET     With  P  the selection is confirmed and the device changes into menu group level      ALI           The same applies to  ALZ  to  AL4      Programming interlock     Description see page 11  menu level RUN    Menu group level       6  Reset to factoty settings    To return the unit to a defined basic state  a reset can be carried out to the default values   The following procedure should be used    e Switch off the power supply   e Press button  P     e Switch on voltage supply and press  P  button until              is shown in the display     With reset  the default values of the program table are loaded and used for subsequent operation  This sets  the unit back to the state in which it was supplied     Caution  All application related data are lost     18    7  Alarms   Relais          7  Alarms   Relays    This device has 4 virtual alarms that can monitor one limit value in regard of an undercut or  exceedance     Function principle of alarms   relays    Alarm   Relay x Deactivated  instantaneous value  min max value  Hold value  totaliser  value    Switching threshold Threshold   limit value of the change over  Broadness of the window between the switching thresholds  Working principle Operating strom   Quiescent current       Alarms Operating current    By operating current the alarm S1 S4 is off below  the threshold and on on reaching the threshold                     Threshold  On iee
19. s tenfold to PACE Y with factor 1000  The change  acceleration is gradually increased at permanent active up or down     Setting the decimal point  DOT   Default  0    The decimal point on the display can be moved with  A   Y  and confirmed with  P   The  display then switches back to the menu level again  The adjusted decimal point has no  influence on the increment and is displayed without additional dependency     Setting up the switching on behaviour  RESET   Default  L STAR    LSAUE q LUSERr e P   With this parameter the setpoint behaviour after the switching on of the device can be selected  by  A   Y  and confirmed with  P   With L SA  E the last effective setting is taken over as    setpoint during switching on  the change is taken over after 30 seconds and is then available as  initial value  At L STAR the defined initial value START is loaded     Setting the active input level   N LEV   Default  LOUU    The active input level can be adjusted to LOW or HIGH with  A   Y   With  P  the selection is  confirmed and the display changes back into menu level  This is a very important setting  as it  is used for all operation types TYPE     Setting the code for the adjustment lock  5 CODE   Default  0000    gJighghg ae       The code for the adjustment lock is set from the smallest to the highest digit with  A   Y  and  confirmed digit per digit with  P   After the last digit the display changes back into menu level  If  the 5 CODE is set on a value unequal 0000  the code lo
20. sing dimensions  B48xH24xD90 mm    A     Display type  Setpoint generator     e     Protection class     1  without keypad  operation  Display colour via PM TOOL    Blue B   z  iPe5   pluggable terminal  Green   Red PR   Voltage supple   Yellow  7  24 voc gan  isolated  Number of digits Measuring input   5 digit Lo  without   Digit height Analog output   10 mm  x o 10 voc  0 4 20 ma  Digital input Sensor supply    2 digital inputs  Standard  without     e           Please state physical unit by order  e g       Contents    1  2  3   4    Brief description   Assembly   Electrical connection   Functions and operation description   4 1  Programming software PM TOOL   Setting up the device   5 1  Switching on   5 2  Standard parameterisation  flat operation level   Value assigment for the triggering of the signal output    5 3  Programming interlock RUN   Activation Deactivation of the programming interlock or change into the professional level  respectively back into the flat operation level    5 4  Extended parameterisation  professional operation level   5 4 1  Signal input parameter    INP     Value assigment for setpoint  triggering of the digital inputs and assignment of keys  as well as    the behaviour at device start    5 4 2  General device parameter   FLT     Adjustment of the optical alarm  display flashing     5 4 3  Safety parameter    OD       Assignment of user and master code for locking or access to certain  parameters like e g  analog output and alarms  etc    
21. t    User code  4 digit number combination free available   U CODE   Default  0000    g P g P g    g   e       With this code   gt 0000   all parameters are locked  if LOC was selected under menu item RUN  before  By pushing  P  for approx  3 seconds during operation mode  the message CODE  appears in the display  To get to the reduced parameters that were activated for the user  the  preset U CODE needs to be entered  This code has to be entered before each attempt of  parameterisation  until the A CODE  Master code  activates all parameters again     Master code  4 digit number combination free available   A CODE   Default  1234    gelgelgeg st    This code can activate all parameters  after LOC has been activated under menu item RUN  before  By pushing  P  for approx  3 seconds during operation mode  the message CODE  appears in the display and thus enables the user to reach all parameters by entering the A CODE   Under RUN the parameterisation can be activated permanently by selecting ULOC or PROF  thus at  an anew pushing of  P  in operation mode  the code needs not to be entered again        10    5  Setting up the device       Menu level Parameterisation level  5 3  Programming interlock    Activation   Deactivation of the programming interlock or completion of the standard  parameterisation with change into menu group level  complete function volume   RUN   Default  ULOC    Loc    PraF 2 E     Choose between the deactivated key lock ULOC  works setting   the activated
22. t lock is  controlled  With E TAST the adjustment of the setpoint via the external inputs 1     and 2     is  done  There is no additional input lock  This has to be realised by an electrical connection ot the  keys if required  Confirm the selection with  P  and the display switches back to menu level           11    5  Setting up the device    Menu level Parameterisation level    Setting up the adjustment end value  END   Default  10000    Set the end value from the smallest to the highest digit with  A   Y  and confirm each digit with   P   A minus sign can only be parameterized on the leftmost digit  After the last digit  the display  switches back to the menu level  The value that is set here  can later on not be exceeded while  adjusting the setpoint     Setting up the adjustment start offset value  OFFS   Default  0    g P g P gP gegee    Enter the start offset value from the smallest to the highest digit with  A   Y  and confirm each  digit with  P   A minus sign can only be parameterized on the leftmost digit  After the last digit  the display switches back to the menu level  The value that is set here  can later on not be  undercut while adjusting the setpoint     Setting up the adjustment initial value  START   Default  0    gP gP gP g Pg le       The initial value  which is loaded by start or by pushing  A   Y  at the same time  is adjusted  from the smallest to the highest digit with  A   V  and confirmed digit per digit with  P   A  minus sign can only be parame
23. terized on the leftmost digit  After the last digit the display  changes back into menu level     Setting up the increments  STEP   Default  7    gP aP g Pg Ppe eR    The increments for the adjustment types F TAST and E TAST are adjusted from the smallest to the  highest digit with  A   V  and confirmed digit per digit with  P   After the last digit the display  changes back into menu level  Per keystroke the setpoint is changed by the increment  which  can be selected from 1   99999        Maximum possible change acceleration  SPEED   Default  PACE 4    PACE      PACE    PACES    PACEY    P     Via SPEED the maximum possible change accleration of the setpoint in permanent activation of  up or down can be set  At PACE  no multiplication of the increment takes place  For each other  Pace step the maximum speed muliplies tenfold to PACE Y with factor 1000  The change  acceleration is gradually increased at permanent active up or down        12    5  Setting up the device       Menu level Parameterisation level    Setting the decimal point  DOT   Default  0    aon  a   vy v     The decimal point on the display can be moved with  A   Y  and it is confirmed with  P   The  display then switches back to the menu level again  The adjusted decimal point has no  influence on the increment and is displayed without additional dependency     Setting up the switching on behaviour  RESET   Default  L STAR    With this parameter the setpoint behaviour after the switching on of the device can
24. y mode     5 2  Standard parameterisation   flat operation level     To parameterize the display  press the  P  key in operating mode for 1 second  The display then changes to the  menu level with the first menu item TYPE     Menu level Parameterisation level    Selection of the adjustment type for the setpoint   default value  TYPE   Default  F TAST    FEASE   F InPy SEEASE   FP     With F TAST the setpoint is adjusted by  A   Y   furthermore the adjusment can be locked via  the external input 1  At F INPU there is a direct selective input of the setpoint via  P   A   Y   For  the adjustment the key  A  or  V  needs to be pressed first  Via input 1 the adjustment lock is  controlled  With E TAST the adjustment of the setpoint via the external inputs 1     and 2     is  done  There is no additional input lock  This has to be realised by an electrical connection of the  keys if required  Confirm the selection with  P  and the display switches back to menu level     Setting up the adjustment end value  END   Default  10000    e  g Bge gegee    Set the end value from the smallest to the highest digit with  4   Y  and confirm each digit with   P   A minus sign can only be parameterized on the leftmost digit  After the last digit  the display  switches back to the menu level  The value that is set here  can later on not be exceeded while  adjusting the setpoint     Setting up the adjustment start offset value  OFFS   Default  0    pXgepegehesel    Enter the start offset value from
    