Home
User Manual Draco (Cross) Repeater
Contents
1. 26 7 1 2 Fiber SFP Type LC Interconnect 26 7 2 Interconnect CGable AAA 27 Zi OR EE 27 EC dene 28 7 9 Connector il Le EE 29 1 4 Power NOI eebe 30 7 5 Environmental Conditions 30 o Plz een 31 7 7 Shipping Weght nennen nennen nenne 32 TFOUDIESHOONNG sissi 33 8 1 General Failures nennen nnnnne nennen 33 Technical Support an 34 9 1 Support CheCKIISt iii 34 9 2 Shipping Checklist 34 CCT ERI CACC S iii 35 10 1 CE Declaration Of Conformity 35 10 2 North American Regulatory Compliance 36 108 Product Sally 36 IO VE EEE ee ee ee 37 110 5 ele Le 37 Een N E E EE E E E A A 38 2014 04 15 About This Manual 1 1 1 About This Manual Scope This manual describes how to install your Cross Repeater how to operate it and how to perform trouble shooting Validity This manual is valid for all devices listed on the front page The product code is printed on the base of the devices Cautions and Notes The following symbols are used in this manual This symbol indicates an important operating instruction that should be followed to avoid any potential damage to hardware or property loss of data or personal injury This symbol indicates important information to help you make the best use of this product This symbol indicates best practice information to show recommended and optimal ways to use this product
2. 3 6 7 21 fold Vario Chassis 474 BODY21R CPU and CON Unit O O EB O 1 Rear View 1 Slots for modules 1 21 da EE 8 Be _ DI w T 1 2 3 4 Front View 1 Connect to power supply 2 Locking for power supply 2 redundancy Locking for power supply 1 standard KR O N Connect to power supply 1 2014 04 15 17 Draco Cross Repeater 3 6 8 3 6 9 3 6 10 18 Model 485 BC Module Rear View 1 Service port 2 Connect to interconnect cable 1 3 Connect to interconnect cable 2 Model 485 BS Module 0 W 0 1 2 3 Rear View 1 Service port 2 Connect to interconnect cable 1 3 Connect to interconnect cable 2 Model 485 BX Module LEL 1 2 3 Rear View 1 Service port 2 Connect to interconnect cable 1 3 Connect to interconnect cable 2 2014 04 15 3 6 11 Model 485 BCC Module Rear View 1 Service port repeater 1 2 Connecttointerconnect cable 1 repeater 1 3 Connect to interconnect cable 2 repeater 1 Service port repeater 2 Connect to interconnect cable 1 repeater 2 6 Connect to interconnect cable 2 repeater 2 3 6 12 Model 485 BSS Module Rear View 1 Service port repeater 1 2 Connect to interconnect cable 1 repeater 1 3 Connect to interconnect cable 2 repeater 1 Service port repeater 2 Connect to interconnect cable 1 repeater 2 6 Connect to
3. CPU Unit CON Unit 442 x 250 x 41 mm 17 4 x 9 8 x 1 7 Shipping Box 550 x 372 x 155 mm 21 7 x 14 6 x 6 1 Devices in the 21 fold Vario Chassis CPU Unit CON Unit 482 x 462 x 176 mm 19 0 x 18 2 x 6 9 Shipping Box 645 x 574 x 368 mm 25 4 x 22 6 x 14 5 2014 04 15 31 Draco Cross Repeater 7 7 Shipping Weight Devices in the 2 fold Vario Chassis 1 CPU Unit CON Unit 0 4 kg 0 9 Ib Shipping Box 2 2 kg 4 9 Ib Devices in the 2 fold Vario Chassis 2 CPU Unit CON Unit 0 8 kg 1 8 Ib Shipping Box 2 6 kg 5 7 Ib Devices in the 4 fold Vario Chassis CPU Unit CON Unit 0 9 kg 2 0 Ib Shipping Box 3 4 kg 7 5 Ib Devices in the 6 fold Vario Chassis 6R CPU Unit CON Unit 1 4 kg 3 1 Ib Shipping Box 4 6 kg 10 1 Ib Devices in the 6 fold Vario Chassis 6BP 6BPF CPU Unit CON Unit 2 5 kg 5 5 Ib Shipping Box 3 5 kg 7 7 Ib Devices in the 21 fold Vario Chassis CPU Unit CON Unit 10 0 kg 22 1 Ib Shipping Box 14 5 kg 32 0 Ib 32 2014 04 15 Troubleshooting 8 Troubleshooting 8 1 General Failures Module ma IR 234 5 1 23 45 12 3 45 Rear View LED 3 off Power supply gt Check power supply units and the connection to the power network LED 2 off or Connection between Check interconnect cables and LED 5 off Cross Repeater and connections KVM extender unit or KVM matrix 2014 04 15 33 Draco C
4. configuration of a monitor driver by the operating system Dual Access A system to operate a source computer CPU from two consoles Dual Link A DVI D interface for resolutions up to 2560x2048 by signal transmission of up to 330 MPixel s 24 bit Dual Head A system with two video connections 2014 04 15 Glossary erm DVI Digital video standard introduced by the Digital Display Working Group http www ddwg org Single Link and Dual Link standard are distinguished The signals have TMDS level A combined signal digital and analog that allows running a VGA monitor at a DVI I port in contrast to DVI D see DVI The Enhanced Graphics Adapter EGA is an old analog graphic standard introduced by IBM in 1984 A D Sub 9 connector is used for connection Single mode or multi mode fiber cables An interface for an all digital transmission of audio and video data It is differentiated between the HDMI standards 1 0 to 1 4a The signals have TMDS level Keyboard video and mouse Mini XLR Industrial standard for electrical plug connections 3 pole for the transmission of digital audio and control signals Multi mode 62 54 multi mode fiber cable or 50u multi mode fiber cable OSD The On Screen Display is used to display information or to operate a device Quad Head A system with four video connections RCA Cinch A non standard plug connection for transmission of electrical audio and video signals especial
5. is basically used in order to double the maximum cabling distance between a KVM extender CON or CPU Unitoreven a KVM matrix In addition to that the device can also be used for media conversion from Cat X to fiber or vice versa The device is available as a pure Cat X or fiber version repeater and as a hybrid version of Cat X and fiber cross repeater for an additional electrical optical signal conversion 2014 04 15 7 Draco Cross Repeater 3 2 System Overview The Cross Repeater consists of at least one module depending on the application The device is connected between a KVM extender CON and CPU Unit via the interconnect cable or can be alternatively connected between a KVM extender unit and a KVM matrix The Cross Repeater communicates with both the KVM extenders and a KVM Matrix via the interconnect cables 1 2 3 4 5 6 7 System Overview 1 2 3 4 5 6 T Source computer CPU KVM Extender CPU Unit Interconnect cable Cat X or fiber Cross Repeater Interconnect cable Cat X or fiber KVM Extender CON Unit Console monitor keyboard mouse See Chapter 4 3 Page 23 for installation examples 2014 04 15 3 3 Product Range 3 3 1 Chassis Model Description 474 BODY2 Empty chassis for up to 2 boards 1x external power supply unit 474 BODY2R Empty chassis for up to 2 boards 1x external power supply unit preparation for redundancy for a second power
6. supply unit external 474 BODY2N Empty chassis for up to 2 boards 1x internal power supply unit preparation for redundancy for a second power supply unit external 474 BODY4 Empty chassis for up to 4 boards 1x external power supply unit 474 BODY4R Empty chassis for up to 4 boards 1x external power supply unit preparation for redundancy for a second power supply unit external 474 BODY6R Empty chassis for up to 6 boards 1x internal power supply unit preparation for redundancy for a second power supply unit external 474 Empty chassis for up to 6 boards active backplane 2x BODY6BP internal power supply unit redundancy 474 Empty chassis for up to 6 boards active backplane 2x BODY6BPF internal power supply unit redundancy with connectors on rear side 474 Empty chassis for up to 21 boards 1x internal power BODY21 4U supply unit preparation for redundancy for a second power supply unit internal 2014 04 15 9 Draco Cross Repeater 3 3 2 3 4 10 Cross Repeater Modules Model Description 485 BC Repeater module Cat X for range extension up to 280 m 485 BS Repeater module fiber Single Mode for range extension up to 20 000 m 485 BX Repeater module Cat X fiber Single Mode for an electrical optical media conversion maximum extension 10 140 m 485 BCC Dual repeater module Cat X for range extension up to 280 m 485 BSS Dual repeater module fiber Single Mode for range extens
7. the manufacturer SFP modules can be damaged by electrostatic discharge ESD gt Please consider ESD handling specifications 2014 04 15 Specifications 7 2 7 2 1 A A Interconnect Cable Cat X A point to point connection is required Operation with several patch fields is possible Routing over an active network component such as an Ethernet Hub Router or Matrix is not allowed gt Avoid routing Cat X cables along power cables gt If the site has 3 phase AC power try to ensure that CPU Unit and CON Unit are on the same phase To maintain regulatory EMC compliance correctly installed shielded Cat X cable must be used throughout the interconnection link To maintain regulatory EMC compliance all Cat X cables need to carry ferrites on both cable ends close to the device Type of Interconnect Cable The Cross Repeater requires interconnect cabling specified for Gigabit Ethernet 1000BASE T The use of solid core AWG24 shielded Cat 5e or better is recommended Cat X Solid Core Cable S UTP Cat 5e cable according to EIA TIA AWG24 568 B Four pairs of wires AWG24 Connection according to EIA TIA 568 B 1000BASE T Cat X Patch Cable S UTP Cat 5e cable according to EIA TIA AWG26 8 568 B Four pairs of wires AWG26 8 Connection according to EIA TIA 568 B 1000BASE T The use of flexible cables patch cables type AWG26 8 is possible however the maximum possible extension d
8. 1 3 Cautions and Notes nennen nennen 5 Safety Instructions iind 6 DESCHID ON EE 7 3 1 APPIICATON ur 7 3 2 System Overvi W nennen 8 3 3 Product Range RE 9 3 3 1 MER 9 3 3 2 Cross Repeater Modules nnn0nnn0nnnennnannnennn 10 3 4 Accessories Uooradeks Rennen nennen 10 3 9 ACCESSOS easain EAER 11 3 6 Device VIEWS ii 11 3 6 1 2 fold Vario Chassis 474 BODY2 2R 11 3 6 2 2 fold Vario Chassis 474 BODYZ2N 12 3 6 3 4 fold Vario Chassis 474 BODY4 4R 13 3 6 4 6 fold Vario Chassis 474 BODYGR 14 3 6 5 6 fold Vario Chassis 474 BODYG6BP 15 3 6 6 6 fold Vario Chassis 474 BODY6BPF 16 3 6 7 21 fold Vario Chassis 474 BODY21R 17 3 6 8 Model A9pPBC een 18 3 6 9 Model 485 BS i 18 3 6 10 Model 485 BX nn 18 3 6 11 Model 485 BCC 19 3 6 12 Model 485 BSS nenn 19 3 6 13 Model 485 BXX ii 20 GER RE 21 3 7 1 Status Cross Repeater Module 21 2014 04 15 Draco Cross Repeater 4 10 11 Installa io M se iena 22 4 1 Package Contents i 22 4 2 System anschlelien 22 4 2 1 Cross Repeater Setup ccceccceseeeeeeeeeeeeeeees 22 4 3 Example Applications 23 Configuratio ME 25 Operational 25 SS DEES 26 7 1 NIS Ace ee ee Eee 26 7 1 1 RJ45 Interconnect
9. 15
10. 4 IEC connection cable for power supply lockable PSULOCK Device Views 2 fold Vario Chassis 474 BODY2 2R CPU and CON Unit 3 4 1 2 Rear View 1 Slot for modules 1 2 Connect to 5VDC power supply standard 3 Slot for modules 2 4 Connect to 5VDC power supply redundancy optional 2014 04 15 11 Draco Cross Repeater 3 6 2 2 fold Vario Chassis 474 BODY2N CPU and CON Unit 3 4 mi Rear View 1 2 3 4 Slot for modules 1 Connect to power supply standard Slot for modules 2 Connect to 5VDC power supply redundancy The 2 fold vario chassis with an internal power supply is not equipped with a fuse on its primary side Therefore the protection against excessive currents has to be provided by the electrical installation of the building 12 2014 04 15 3 6 3 4 fold Vario Chassis 474 BODY4 4R CPU and CON Unit 4 5 6 I 1 2 3 Rear View Slot for modules 3 Slot for modules 1 Connect to 5VDC power supply standard Slot for modules 4 Slot for modules 2 Ooo Aa W N gt Connect to 5VDC power supply redundancy optional For operation with three KVM Extender CON modules and a USB 2 0 CON module in a 4 fold vario chassis two power supplies are necessary In this case redundancy is inapplicable 2014 04 15 13 Draco Cross Repeater 3 6 4 6 fold Vario Chassis 474 BO
11. DY6R CPU and CON Unit 6 8 m 4 2 3 4 5 Rear View Slot for modules 5 Slot for modules 3 Slot for modules 1 Connect to power supply standard Connect to 5VDC power supply standard Slot for modules 6 Slot for modules 4 CON O Oo A W N gt Slot for modules 2 For operation with KVM Extender modules in a 6 fold vario chassis two power supplies are necessary In this case redundancy is inapplicable The 6 fold vario chassis is not equipped with a fuse on its primary side Therefore the protection against excessive currents has to be provided by the electrical installation of the building 14 2014 04 15 3 6 5 6 fold Vario Chassis 474 BODY6BP CPU and CON Unit 1 2 3 Front View 1 Connect to power supply 1 2 Connect to power supply 2 redundancy 3 Grounding 4 1 Rear View 1 Slot for modules 5 2 Slot for modules 3 3 Slot for modules 1 A Slot for modules 6 5 Slot for modules 4 6 Slot for modules 2 2014 04 15 15 Draco Cross Repeater 3 6 6 6 fold Vario Chassis 474 BODY6BPF 16 CPU and CON Unit 6 7 8 1 2 3 Rear View Slot for modules 5 Slot for modules 3 Slot for modules 1 Connect to power supply 1 Connect to power supply 2 redundancy Slot for modules 2 Slot for modules 4 Slot for modules 6 COON OO A Go N gt 2014 04 15
12. da INSE Draco User Manual Edition 2014 04 15 Draco Cross Repeater Model 485 Series 7 Vo Draco vario 4 gt IHSE GmbH Maybachstrasse 11 88094 Oberteuringen Germany info ihse de www ihse de Tel 49 7546 9248 0 Fax 49 7546 9248 48 Draco Cross Repeater Copyright 2014 All rights reserved This information may not be reproduced in any manner without the prior written consent of the manufacturer Information in this document is subject to change without notice Trademarks All trademark and trade names mentioned in this document are acknowledged to be the property of their respective owners Disclaimer While every precaution has been taken during preparation of this manual the manufacturer assumes no liability for errors or omissions The manufacturer assumes no liability for damages resulting from the use of the information contained herein The manufacturer reserves the right to change specifications functions or circuitry of the product without notice The manufacturer cannot accept liability for damage due to misuse of the product or due to any other circumstances outside the manufacturer s control whether environmental or installation related The manufacturer shall not be liable for any loss damage or injury arising directly indirectly incidentally or consequently from the use of this product 2014 04 15 Contents 1 ADOUC Elsass rer 5 1 1 EE 5 t2 al e E 5
13. he provisions of the following European Directives 2004 108 EG Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility CE CE Marking 2009 Product list 485 Series The products comply with the following harmonized standards for Information Technology Equipment e EN 55022 2010 A1 2007 Class A s EN 55024 2010 A1 2001 A2 2003 This declaration certifies the conformity to the specified directives but contains no assurance of properties The safety instructions and installation guidelines noted in this manual shall be considered in detail Compliance with the specifications for cable lengths and types is mandatory Manufacturer Oberteuringen 26 January 2010 IHSE GmbH The Management Maybachstrasse 11 ga 88094 Oberteuringen au O Ze OR Deutschland Use in a Domestic Environment This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 2014 04 15 35 Draco Cross Repeater 10 2 10 3 36 North American Regulatory Compliance This equipment has been found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre
14. his application scenario will be primarily recommended if connections through KVM matrix must be bypassed in case of major matrix problems Therefore KVM extenders with Cat X and with fiber connector can be directly connected to each other 2014 04 15 23 Draco Cross Repeater 1 2 3 4 5 6 7 8 9 Dual Media Conversion Source computer CPU KVM Extender CPU Unit Interconnect cable Cat X Cross Repeater 1 Interconnect cable fiber Cross Repeater 2 Interconnect cable Cat X KVM Extender CON Unit Console monitor keyboard mouse oO ON OO P W NBS gt 24 2014 04 15 Configuration 5 Configuration The Cross Repeater does not require any configuration and is ready for use per default 6 Operation The Cross Repeater does not have any adjustable operating modes and is ready for use per default 2014 04 15 25 Draco Cross Repeater 7 7 1 7 1 1 7 1 2 26 Specifications Interfaces RJ45 Interconnect Communication between Cat X devices requires a 1000BASE T connection Connector wiring must comply with EIA TIA 568 B 1000BASE T with RJ45 connectors at both ends All four cable wire pairs are used Fiber SFP Type LC Interconnect Communication of fiber devices is performed via Gigabit SFPs that are connected to suitable fibers fitted with connectors type LC see Chapter 7 2 2 Page 28 The correct function of the device can only be guaranteed with SFPs provided by
15. in an efficient way 2014 04 15 5 Draco Cross Repeater 2 Safety Instructions To ensure reliable and safe long term operation of your Cross Repeater please note the following guidelines Installation gt gt dh gt gt Only use in dry indoor environments The Cross Repeater and the power supply units can get warm Do not install components in an enclosed space without any airflow Do not place the power supply directly on top of the device Do not obscure ventilation holes Only use power supplies originally supplied with the product or manufacturer approved replacements Do not use a power supply if it appears to be defective or has a damaged chassis Connect all power supplies to grounded outlets In each case ensure that the ground connection is maintained from the outlet socket through to the power supply s AC power input Do not connect the link interface to any other equipment particularly network or telecommunications equipment Take any required ESD precautions In order to disconnect the device completely from the electric circuit all power cables have to be removed Repair gt Do not attempt to open or repair a power supply unit gt Do not attempt to open or repair the Cross Repeater There are no user serviceable parts inside gt Please contact your dealer or manufacturer if there is a fault 2014 04 15 3 Description 3 1 Application The Cross Repeater
16. interconnect cable 2 repeater 2 2014 04 15 19 Draco Cross Repeater 3 6 13 Model 485 BXX 20 Module TRL AIA 1 2 3 4 5 6 Rear View 1 Service port repeater 1 2 Connect to interconnect cable 1 repeater 1 3 Connect to interconnect cable 2 repeater 1 Service port repeater 2 Connect to interconnect cable 1 repeater 2 6 Connect to interconnect cable 2 repeater 2 2014 04 15 3 7 3 7 1 Status LEDs Status Cross Repeater Module The Cross Repeater module is fitted with a multi color LED for overall status indication and with two further LEDs for indication of the connection status Module RR du 1 234 5 1 23 45 t 12 3 45 Rear View Rear View LED 1 2 and 4 5 Connection Status Pos LED Statue pescripion Failure LED Off Connection available green On or Connection failure flashing for about Flashing 20 s following a connection failure 2 5 Status LED Flashing No connection via interconnect cable green Connection available LED 3 Device Status Pi Olm Link 1 left connector available Link 2 right Blue connector not Deal Green Link 2 right connector available Link 1 left connector not detected Light Blue Link 1 left connector and Link 2 right connector available 2014 04 15 21 Draco Cross Repeater 4 4 1 4 2 1 22 Installation Package Contents You
17. ion up to 20 000 m 485 BXX Repeater module Cat X fiber Single Mode for an electrical optical media conversion maximum extension 10 140m Accessories Upgrade Kits Model Description O 474 2RMK_ 19 1U rack mount kit for 2 fold chassis 474 19 1U rack mount kit for 2 fold chassis with internal PSU 2NRMK 474 4RMK_ 19 1U rack mount kit for 4 fold chassis 474 6RMK_ 19 1U rack mount kit for 6 fold chassis 474 Fastening strips for screw or snap on for 2 4 and 6 fold VPLATE chassis 474 Retrofitting for redundant power supply option without OPTRED power supply for 2 and 4 fold chassis 474 PSU2 Power supply for 2 fold chassis spare or redundancy 474 PSU4 Power supply for 4 fold chassis spare or redundancy 474 PSU6 Power supply for 6 fold chassis spare or redundancy 474 PSU21 Power supply for 6 fold chassis spare or redundancy 474 BLND1 Blind plate 3U 4HP for 2 4 and 6 fold chassis 474 BLND2 Blind plate 3U 8HP for 2 4 and 6 fold chassis 2014 04 15 d 3 9 3 6 3 6 1 Cross Repeaters and the power supply units can get warm and must not be installed in closed rooms with no air circulation For rack mount installations at least 0 5 U height unit is required above the Cross Repeater for ventilation Accessories Model Description S 260 5G International power supply unit 100 240 VAC 5 VDC 3A 260 5U International power supply unit 100 240 VAC 5 VDC 4 A 47
18. istance is halved Maximum Acceptable Cable Length Cat X Installation Cable 140 m 400 ft AWG24 Cat X Patch Cable 70 m 200 ft AWG26 8 2014 04 15 27 Draco Cross Repeater 7 2 2 Fiber d 28 A point to point connection is necessary Operation with multiple patch panels is allowed Routing over active network components such as Ethernet Hubs Switches or Routers is not allowed Type of Interconnect Cable Cable notations according to VDE Type of cable Specifications Single mode 9um Two fibers 9um I V ZN H 2E9 in house patch cable I V ZN HH 2E9 in house breakout cable VAD ZN H 4E9 in house or outdoor breakout cable resistant A DQ ZN B2Y 4G9 outdoor cable with protection against rodents Multi mode 50um Two fibers 50um I V ZN H 2G50 in house patch cable IAD ZN H 4G50 in house or outdoor breakout cable resistant Multi mode 62 5um Two fibers 62 5um I V ZN HH 2G62 5 in house breakout cable A DQ ZN B2Y 4G62 5 outdoor cable with protection against rodents Maximum Acceptable Cable Length Type of cable Maximum Acceptable Cable Length Single mode 9um 10 000 m 32 800 ft J I Multi mode 50um OM3 1 000 m 3 280 ft Multi mode 50um 400 m 1 300 ft Multi mode 62 5um 200 m 650 ft If you use single mode SFPs with multi mode fibers you normally can double the maximum acceptable cable length Type of Connector 2014 04 15 Specifications 7 3 Connecto
19. ly with coaxial cables S PDIF A digital audio interconnect that is used in consumer audio equipment over relatively short distances SFP SFPs Small Form Factor Pluggable are pluggable interface modules for Gigabit connections SFP modules are available for Cat X and fiber interconnect cables Single Link A DVI D interface for resolutions up to 1920x1200 by signal transmission of up to 165 MPixel s 24 bit Alternative frequencies are Full HD 1080p 2K HD 2048x1080 and 2048x1152 Single Head A system with one video connection Single mode Qu single mode fiber cable 2014 04 15 39 Draco Cross Repeater S Video Y C S Video Y C is a video format transmitting luminance and chrominance signals separately Thereby it has a higher quality standard than CVBS TOSLINK Standardized fiber connection system for digital transmission of audio signals F05 plug connection Triple Head A system with three video connections USB HID USB HID devices Human Interface Device allow for data input There is no need for a special driver during installation New USB HID device found is reported Typical HID devices include keyboards mice graphics tablets and touch screens Storage video and audio devices are not HID VGA Video Graphics Array VGA is a computer graphics standard with a typical resolution of 640x480 pixels and up to 262 144 colors It can be seen as a follower of the graphics standards MDA CGA and EGA 40 2014 04
20. quency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances All power supplies are certified to the relevant major international safety standards Product Safety The product safety of the devices is proven by the compliance to the following standards e TEC 60950 1A1 2010 e EN 60950 1 A12 2011 e UL 60950 1 2007 e CAN CSA C22 2 60950 1 07 The compliance is verified and confirmed by T V S d Germany 2014 04 15 Certificates 10 4 WEEE The manufacturer complies with the EU Directive 2012 19 EU on the prevention of waste electrical and electronic equipment WEEE The device labels carry a respective marking 10 5 RoHS RoHS 2 This device complies with the Directive 2011 65 EU of the European Parliament and of the council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and elect
21. r Pinouts Connector Mini USB Type B Picture Pin sion Joe 1 veces Ra Fiber SFP Typ LC Picture Diode Signal SSS 1 Data OUT 2014 04 15 29 Draco Cross Repeater 7 4 7 9 30 Power Supply AC Power Supply Model max Current Max Voltage Frequency 474 BODY6BPF 800 mA max 100 240 V 50 60 Hz 474 BODY21 4U 4 000 mA max 2x 100 240 V 50 60 Hz DC Power Supply Model Max Current Max Voltage Power Requirement Power Requirement Cross Repeater per Unit e Max 300 mA Environmental Conditions Operating Temperature 41 to 113 F 5 to 45 C Storage Temperature 13 to 140 F 25 to 60 C Relative Humidity Max 80 non condensing 2014 04 15 Specifications 7 6 Size Devices in the 2 fold Vario Chassis 1 CPU Unit CON Unit 145 x 147 x 41 mm 5 7 x 5 8 x 1 7 Shipping Box 210 x 140 x 165 mm 8 3 x 5 5 x 6 5 Devices in the 2 fold Vario Chassis 2 CPU Unit CON Unit 221 x 147 x 41 mm 8 7 x 5 8 x 1 7 Shipping Box 550 x 365 x 115 mm 21 7 x 14 4 x 4 5 Devices in the 4 fold Vario Chassis CPU Unit CON Unit 293 x 147 x 41 mm 11 5 x 5 8 x 1 7 Shipping Box 550 x 365 x 115 mm 21 7 x 14 4 x 4 5 Devices in the 6 fold Vario Chassis 6R CPU Unit CON Unit 442 x 147 x 41 mm 17 4 x 5 8 x 1 7 Shipping Box 760 x 365 x 115 mm 29 9 x 14 4 x 4 5 Devices in the 6 fold Vario Chassis 6BP 6BPF
22. r extender package contains the following items Cross Repeater e Cross Repeater in the vario chassis e 1x redundancy 2x 5 VDC international power supply unit per KVM Extender unit depending on chassis e 1x redundancy 2x country specific power cord depending on chassis e Quick Setup If anything is missing contact your dealer System anschlie en First time users are recommended to setup the system in the same room as a test setup This will allow you to identify and solve any cabling problems and experiment with your system more conveniently gt Please verify that interconnect cables interfaces and handling of the devices comply with the requirements see Chapter 7 Page 26 Cross Repeater Setup 1 Switch off all devices 2 Connect the Cross Repeater with the interconnect cable s 3 Connect the chassis of the Cross Repeater to the power supply 4 Power up the system To power up the system the following sequence is recommended Monitor CON Unit Cross Repeater CPU Unit source 2014 04 15 Installation 4 3 Example Applications This section illustrates typical installations of Cross Repeaters 1 2 3 4 5 6 7 Single Media Conversion Source computer CPU KVM Extender CPU Unit Interconnect cable Cat X Cross Repeater Interconnect cable fiber KVM Extender CON Unit Console monitor keyboard mouse N DO dl SA W N gt The example shown in t
23. ronic equipment RoHS 2 RoHS II The device labels carry a respective marking 2014 04 15 37 Draco Cross Repeater 11 38 Glossary The following terms are commonly used in this guide or in video and KVM technology Term Explanation AES EBU Digital audio standard that is officially known as AES3 and that is used for carrying digital audio signals between devices Any Cat 5e Cat 6 Cat 7 cable CGA Color Graphics Adapter CGA is an old analog graphic standard with up to 16 displayable colors and a maximum resolution of 640x400 pixels Component Component Video YPbPr is a high quality video Video standard that consists of three independently and separately transmittable video signals the luminance signal and two color difference signals Composite Video Composite Video is also called CVBS and it is part of the PAL TV standard CON Unit Component of a KVM Extender or Media Extender to connect to the console monitor s keyboard and mouse optionally also with USB 2 0 devices Keyboard mouse and monitor CPU Unit Component of a KVM Extender or Media Extender to connect to a source computer CPU CVBS The analog color video baseband signal CVBS is also called Composite Video and it is part of the PAL TV standard DDC Display Data Channel DDC is a serial communication interface between monitor and source computer CPU It allows a data exchange via monitor cable and an automatic installation and
24. ross Repeater 9 Technical Support Prior to contacting support please ensure you have read this manual and then installed and set up your Cross Repeater as recommended 9 1 Support Checklist To efficiently handle your request it is necessary that you complete a support request checklist Download Please ensure that you have the following information available before you call Company name phone number and email Type and serial number of the device see bottom of device Date and number of sales receipt name of dealer if necessary Issue date of the existing manual Nature circumstances and duration of the problem Components included in the system such as graphic source CPU OS graphic card monitor USB HID USB 2 0 devices interconnect cable including manufacturer and model number Results from any testing you have done 9 2 Shipping Checklist 1 2 3 d 34 To return your device contact your dealer to obtain aRMA number Return Material Authorization Package your devices carefully preferably using the original box Add all pieces which you received originally Note your RMA number visibly on your shipment Devices that are sent in without aRMA number cannot be accepted The shipment will be sent back without being opened postage unpaid 2014 04 15 Certificates 10 10 1 Certificates CE Declaration Of Conformity The products listed below in the form as delivered comply with t