1. Please refer to maintenance and section if there are still failures during warranty you can return to your retailer 4 please replace another new alarm if the unit is out of warranty The battery is under low battery status please replace the smoke alarm device Clean smoke alarm device Please refer to the maintenance and cleaning section Purchase and change another smoke alarm device if the problem still exist 1 Press test button to pause alarm 2 Clean Please refer to the maintenance smoke alarm device and cleaning section 3 Move smoke alarm device to new location and press test button 1 Clean smoke alarm device Please refer to the maintenance and cleaning section 2 1f there are still failures during warranty you can return to your retailer 3 if the unit is out of warranty please replace another new alarm Practice Fire Safety If the alarm sounds and you have not pushed the test button it is warning of a dangerous situation your immediate response is necessary To prepare for such occurrences develop family escape plans discuss them with all household members and practice them regularly 1 Expose everyone to the sound of a smoke alarm device Version C and explain what the sound means Determine two exits from each room and an escape route to the outside from each exit Teach all household members to touch the door and use an alte
2. chirp approx every 40 seconds and the red LED flash once at the same time for a minimum of thirty days when the battery gets low If there is a defective battery or other failures you can refer to Trouble shooting for solution if there are still failures during warranty you can return to your retailer WARNING The battery is sealed in cover and not replaceable Please replace another new alarm if the low battery chirp occurs IMPORTANT Do not attempt to remove the cover to clean inside This will affect warranty Repair Caution Do not attempt to repair the alarm It will affect your warranty If the alarm is not operating properly and is still under warranty return it to the original place you buy Pack it in a well padded carton and ship to the original place you buy If the alarm is no longer under warranty have a licensed electrician replace it immediately with a comparable alarm Trouble shooting Pee ee Smoke alarm device does not sound when tested The alarm chirp with red LED flashes once every 40 seconds Smoke alarm device chirp occurs every 40 seconds alarm goes into fault mode Smoke alarm device sounds unwanted alarms intermittently or residents when are cooking taking showers etc The different from it is used alarm sounds to It starts and stops Must activate alarm before installation smoke alarm device the cleaning Clean
3. e plastic plugs e b I Insert fixing plug Diagram 6 Manufacturer NINGBO SITERWELL ELECTRONICS CO LTD ADDRESS No 76 Haichuan Road Chuangye Zone B Jiangbei Ningbo China TEL 0086 574 83076656 FAX 0086 574 83076652 E MAIL Sales china ster com Distributor m e GmbH modern electronics An den Kolonaten 37 D 26160 Bad Zwischenahn DoP No 508CPR2014 10 21 Version C
4. will also help Version C remove these combustible particles from the kitchen The alarm silence test button is extremely useful in a kitchen area or other areas prone to nuisance alarms The silence feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm The smoke alarm device is desensitised by push the alarm silence silence mode on the smoke alarm device cover the alarm will silence to indicate that the alarm is in a temporarily desensitised condition The smoke alarm device will automatically reset after approximately 10 minutes if after this period particles of combustion are still present the alarm will sound again The alarm silencer silence mode can be repeatedly until the air has been cleared of the condition causing the alarm CAUTION Before using the alarm silence silence identify the source of the smoke and be certain a safe condition exists DANGER If the alarm sounds and it is not being tested it means the unit is sensing smoke THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION Maintenance and Cleaning In addition to weekly testing the alarm requires periodic cleaning to remove dust dirt and debris Clean the alarm at least once a month to remove dust dirt or debris Use a vacuum cleaner with the soft brush vacuum all sides and covers of smoke alarm device This alarm has a low battery monitor which will cause the alarm to
5. Smoke Alarm Device User Manual Model number GS508 Ref ST508 Thank you for purchasing our smoke alarm device Please take a few minutes to read the user s manual thoroughly and familiarize yourself and your family with its operation And save it for future reference fe 8 G214063 CP EN14604 2005 AC 2008 0786 CPR 21388 Diagram 1 Product Specifications POWER built in DC3V CRI23A Lithium battery battery not replaceable OPERATION CURRENT lt 8uA standby alarm ALARM VOLUME gt 85dB A at 3 meters ALARM SENSITIVITY 0 1 0 17dB m SILENCE TIME approx 10 minutes SMOKE ALARM DEVICE SOUND PATTERN BI 0 5s pause 0 5s BI 0 5s pause 0 5s BI 0 5s pause 1 5s with the red LED flash repeat this alarm lt 50mA pattern COMPLY WITH EN14604 2005 AC 2008 Description The unit is a photoelectric smoke alarm device With the photoelectric technology it is more sensitive to detecting slow smolder fires which general thick black smoke a little heat and may smolder for hours before bursting into flames The smoke alarm device does not contain the radioactive material which is harmless to the environment The smoke alarm device should be installed in every room except the bathroom and kitchen and every other area of the home making sure the people in the home will be able to hear and respond to the alarm sound For minimum protection you should fit an alarm respectively fo
6. indicates that it is activated and goes into work status Version C CAUTION MUST activate alarm first or else there is no function for this unit e Turn the alarm body counterclockwise and take off the bracket e Press the bracket on the installation position mark installation hole of the bracket with pencil e Bore two installation holes on the sign with electric drill Make diameter of holes is 5mm Strike the two plastic plugs into holes with hammer e Remove fixing plug from the bracket with screwdriver if necessary Refer to Diagram 4 e Attach the bracket to the plastic plugs and fix tightly the screws into the plastic plugs Refer to Diagram 5 e Fit the alarm on the bracket and turn the alarm body clockwise until matching well on the bracket Insert fixing plug to the gap between bracket and bottom cover for fixing alarm if you want Refer to Diagram 6 e Press the button for test the unit The alarm sounds 3 beeps 1 5 seconds pause repeat it until release the button if no sound it indicates a defective alarm you can refer to Trouble shooting for solution or return to your retailer during warranty If you have any questions on installation you can contact your retailer WARNING To prevent injury this unit must be securely attached to the wall or ceiling in accordance with the installation instructions Remove the fixing plug with screwdriver Diagram 4 holes of ceiling or wall 31 8
7. low O C or rise above 40 C or in humidity higher than 93 These conditions will reduce battery life or cause a fault alarm In extremely dusty dirty or insect infested areas influence particles interfere with smoke alarm device operation Operation Testing Test the unit to ensure proper operation by pressing the test button this will sound the alarm if the electronic circuitry horn and battery are working If no alarm sounds there is a defective battery or other failure you can refer to Trouble shooting section for solution DO NOT use an open flame to test your alarm you could damage the alarm or ignite combustible materials and start a fire CAUTION Due to the loudness 85 decibels of the alarm Always stand an arms length away from the unit when testing Test the alarm weekly to ensure proper operation Erratic or low sound coming from your alarm may indicate a defective alarm you can refer to Trouble shooting section for solution NOTE WEEKLY TESTING IS REQUIERED LED indicators Red LED Flashing once every 40 seconds indicates that the smoke alarm device is operating properly Red LED Flashing when the test button is pressed or when the smoke alarm device sense particles of combustion and goes into alarm constant pulsating sound the red LED will flash once per second The flashing LED and pulsating alarm will continue until the air is cleared or release test button Red LED Alar
8. m silencer Hush mode indication The red LED will flash once every 8 seconds indicating the smoke alarm device is in the alarm silence Hush mode Low battery indication An intermittent chirp with red LED flashes once every 40 seconds indicates that the smoke alarm device is low battery you may press the test button for pause alarm for 10 hours but it will reset automatically after 10 hours Fault indication The alarm chirp occurs every 40 seconds NOTE When the units chirp once every 40 seconds you can press the test button temporarily for pausing this warning tone for 10 hours it can still normally detect smoke during this period it only removes nuisance warning tone You can refer to Trouble shooting for solution if there are still failures you MUST replace it with a new alarm at once or contact you retailer during warranty Alarm silence silence mode During the unit is alarming you push the test button it will be paused the unit alarming for approx 10 minutes The red LED will flash once every 8 seconds it indicates the smoke alarm device is running into the silence mode Smoke alarm devices are designed to minimize nuisance alarms Combustion particles from cooking may set off the alarm if the alarm is located close to the cooking area Large quantities of combustible particles are generated from spills or when grilling frying Using the fan on a range hood that vents to outside non recirculating type
9. ound their alarms when they detect smoke or detect combustion particles in the air They do not sense heat flame or gas This smoke alarm device is designed to give audible warning of a developing fire However many fires are fast burning explosive or intentional and others are caused by carelessness or safety hazards In this circs Smoke may not remake the unit alarm QUICKLY ENOUGH to ensure safe escape Smoke alarm devices have limitations This smoke alarm device is not foolproof and is not warranted to protect lives or property from fire Smoke alarm devices are not a substitute for insurance Homeowners and renters should insure their lives and property In addition it is possible for the smoke alarm device to fail at any time For this reason you must test the smoke alarm device weekly and replace unit every 10 years Do Not Install Smoke alarm devices in the Following Places 1 Near appliances or areas where normal combustion Regularly occurs kitchens near furnaces hot water heaters Use specialized smoke alarm device with unwanted alarm control for this areas In areas with high humidity like bathrooms or areas near dishwashers or washing machines Install al least 10feet away from these areas Near air returns or heating and cooling supply vents Install at least 3 feet away from these areas The air could blow smoke away from the detector interrupting its alarm In rooms where temperatures may fall be
10. r the hallways living room bedrooms and child rooms each unit shall be placed in the middle of the ceiling of each room to protect Typical single storey dwelling with recommended Install a smoke alarm device on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm device at each end If there is a basement install a smoke alarm device on the basement ceiling at the bottom of the stairwell Typical multi storey dwelling with recommended protection Install a smoke alarm device on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm device at each end install a smoke alarm device at the top of a first to second floor stairwell Important Safety Information 1 The test button accurately tests smoke alarm device functions Do not use any other test method Test smoke alarm device weekly to ensure proper operation 2 If you re sure it isn t a really alarm open windows or fan the air around smoke alarm device for silence it 3 This smoke alarm device should be installed only by a licensed qualified electrician Observe and follow all local and national electrical and building codes for installation 4 This smoke alarm device is designed to be used inside a single family only In multifamily b
11. rnate exit when the door is hot instruct them not to open the door if the door is hot Teach household members to crawl along the floor to stay below dangerous smoke fumes and gases Determine a safe meeting place for all members outside the building What to Do in Case of Fire 1 Do not be panic stay calm Leave the building as quickly as possible Touch doors to feel if they were hot before opening them Use an alternate exit 1f necessary Crawl along the floor and do stop to collect anything Meet at a pre arranged meeting place outside the building Call the fire department form outside the building Do not go back inside a burning building Wait for the fire department to arrive Note These guidelines will assist you in the event of a fire however to reduce the chance that fires will start practice fire safety rules and prevent hazardous situations Warranty Information Company warrants to the original consumer Purchase each new smoke alarm device to be free from defects in material and workmanship under normal use and service for a period of 3 years from the date of purchase This watranty does not cover damage resulting from accident misuse or abuse or lack of reasonable care of the product In no case shall company be liable for any incidental or consequential damages for breach of this or any other warranty express or implied whatsoever The bad product can be mailed to the following address wi
12. th a detail explanation of problem Where is the best to be Installed e At first you need install an alarm in the bedroom and route way In the case of several bedrooms you shall install an alarm in every bedroom e Install it in the stairway and in every floor e Smoke heat and burning things will spread horizontally after rising to the ceiling so install the alarm on middle of the ceiling of ordinary structure house let the alarm induce every corner e If alarm couldn t be installed in the middle of the ceiling ode for some reasons the distance which the alarm away form the wall corner should be beyond 50cm e If installed the alarm on the wall it should be 10cm below the ceiling see the diagram 2 If the length of the room or the hall is beyond 30 foot you need install several alarms in the hall e When the wall or ceiling is slanting the alarm needs to be installed minimum 500mm away from the highest wall or ceiling point in the room see the diagram 3 I I ba I CEILING MINIMUM DEAD AIR SPACE 10 cm P 4 MINIMUM HERE pissy 30 5 cm 12 MAXIMUM ACCEPTABLE HERE SIDE WALL Diagram 2 500mm NOT IN THIS AREA we 1000mm K ANYWHERE IN THIS AREA DO NOT INSTALL PEAK CEILING Diagram3 Installation Activation Press test button and hold it for above 3 seconds until LED lights and release it within 2 seconds the unit will generate a beep
13. uildings each individual living unit should have its own smoke alarm devices Do not install in non residential buildings And this smoke alarm device is not a substitute for a complete alarm system 5 Install a smoke alarm device in every room and on every level of the home Smoke may not reach the smoke alarm device for many reasons For example if a fire starts in a remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm device in time to alert household members A smoke alarm device will not promptly detect a fire except in the area or room in which it is installed 6 Smoke alarm device may not alert every household member every time The alarm horn is loud in order to alert individuals to a potential danger However there may be some circumstances where a household member may not hear the alarm i e outdoor or indoor noise sound sleepers drug or alcohol usage the hard of hearing etc If you suspect that this smoke alarm device may not alert a household member install and maintain specialty smoke alarm devices Household member must hear the Version C alarm s warning sound and quickly respond to it to reduce the risk of damage injury or death that may result from fire If a household member is hard of hearing install special smoke alarm devices with lights or vibrating devices to alert occupants 7 Smoke alarm devices can only s