PM 211 – MIP Benutzerhandbuch User Manual Manual de
Contents
1. En el caso de un fallo en el suministro de energ a PM 211 MIP toma en cuenta el ltimo estado de los conmutadores de las conexiones y tan pronto se restablezca el suministro de corriente encender los interruptores que correspondan En cada conector esclavo se pueden conectar dispositivos con un consumo de energ a de hasta 5 ampe rios VA La propia l nea de conectores consume menos de 1 5 vatios to control your world 23 Manual de usuario PM 211 MIP Copyright Infratec AG Bensheim es el propietario de todos los derechos sobre este manual de usuario La reproducci n o reimpresi n de este ma nual tanto sea total como parcial s lo se permitir con una referen cia completa de la fuente de la informaci n Responsabilidad Infratec AG Bensheim ofrece una garant a de 24 meses sobre todos los componentes mec nicos y el ctricos Disponibilidad Infratec AG ha solicitado un n mero EAR Elektro Altger te Register German foundation for Waste Electrical Appliances Register que ser emitido en breve 22 Technische Daten Breite H he Lange Gewicht Leistungsaufnahme Spannung Netzwerkanschluss Anschlussart Masterausgang Slaveausgang je Paar Maximaler Gesamtstrom Schalttart Schaltfunktionen Zulassung Benutzerhandbuch PM 211 MIP 55 mm 55 mm 600 mm 1 5 kg 1 5 VA 85 250 V AC 10 Mbit RJ 45 Je nach Ausf hrung inkl 1 5 m Anschlussleitung max 16 Ampere max 8 Ampere 16 Amp
2. NC el conector mantiene Im Men Network k nnen Sie nun die von Lae su estado vigente con On se enciende y con Off se apaga Ihnen gew nschte IP Nummer einstellen Zum ee bernehmen der Daten m ssen Sie die Steck IP Address iNota Para poder utilizar esta funci n se tendr que confirmar que la l nea dosenleiste rebooten de conectores tiene un n mero IP oficial o que a su enrutador DSL se le ha asignado un nombre claro mediante el servicio de nombres Nach dem Sie die IP Nummer eingestellt ha din mico DNS y que las peticiones sobre el puerto 80 se puede ben k nnen Sie Ihren Rechner wieder auf die ajustar libremente se env an hacia su conector urspr nglichen Einstellungen zur cksetzen zZ 28 INFRATECX to control your world 5 Benutzerhandbuch PM 211 MIP Mozilla Firefox Datei Bearbeiten Ansicht Gehe Lesezeichen Extras Hilfe z E gt gt E amp A http 1217 113 176 157 PM T fus u u L3 Kostenlose Hotmail E Links anpassen windows Media 3 Windows CEEI Power Outlets Network User Update Logout PM211 MIP User Settings Allowed Outlet t Benutzerverwaltung In der Benutzerverwaltung k nnen zwei unterschiedliche Benutzer angelegt werden In den Werkseinstellungen sind bereits drei vor definierte Benutzer angelegt admin user1 und user2 Die Passw rter in den Werkseinstellungen sind mit den Benutzer namen identisch F r jeden Benutzer kann ein Name un
3. The switching point can be adjusted via the rotary control 3 The switching point should be selected so that the consumer at the master socket always oversteps this safely To set proceed as follows Switch the master on and now slowly turn the controller until it reaches the switching point and the master indicator 7 is extin guished Now turn slightly in the opposite direction so that the mas ter indicator 7 lights up again Now please test the function several times If the master indicator lights up whenever the consumer on the master socket is switched the setting has been completed successfully INFRATEC User Manual PM 211 MIP Operation via the command line The socket strip can also be operated via a command line program The following commands are available for this httpget exe is available on the Internet as an option Command usage Or user passwd func s 0 to control your world http ip sw u user amp p passwd amp o n amp f func http ip sw s 0 ipaddress username password outletnumber to switch on off pulse toggle read status 19 User Manual PM 211 MIP User Manual PM 211 MIP Restore factory settings To reset all settings reset has to be pressed until displays 8 8 and 9 light up simultaneously and are then extinguished again The factory settings of the socket strip IP number 192 168 000 211 Gateway 192 168 000 254 Netmask 25
4. MIP Mozilla Firefox Datei Bearbeiten Ansicht Gehe Lesezeichen Extras Hilfe a E O AY os nepirz17 113 176 157 Pw2T up Kostenlose Hotmail Links anpassen Windows Media Windows Outlets Network Update Logout PM211 MIP Update Current software version Y1 00 File to upload MOS Durchsuchen Press Meta llor Te Mia l a Actualizaci n de software Para transferir el software del nuevo sistema operativo primero se tiene que descargar en su ordenador desde el sitio Web de Infra tec AG en Internet el archivo necesario para la actualizaci n Despu s se inicia la sesi n en su conector con su navegador de Internet del modo en que lo realiza normalmente y en el men se selecciona el rea Update actualizaci n Cuando ya se haya localizado el archivo de actualizaci n se inicia el proceso de actualizaci n con el bot n Press pulsar 30 INFRATECX Benutzerhandbuch PM 211 MIP Die Steckdosenleiste im berblick Remote Power f r das Home Office Infratec PM 211 MIP Steckdosenleiste zum Schalten kleiner Rechnerumgebungen Die PM211 MIP verf gt ber eine Ethernet Schnittstelle und kann deshalb mit jedem normalen Switch oder DSL Router verbunden wer den Gesteuert wird sie ber einen integrierten Webserver der die intuitive Konfiguration aller Schaltfunktionen erlaubt und auch eine Verwaltung mehrerer Benutzer mit unterschiedlichen Zugriffsrechten gestattet Die IP Adress
5. esclavos 26 INFRATEC Benutzerhandbuch PM 211 MIP Outlets Network Logout PM 211 MIP Outlets Master Slavei O Slave 2 So Master Bedienung uber das World Wide Web In der Maske fur die Bedienung kann jeder Slave ein und aus geschaltet werden Zusatzlich kann mit dem Button Pulse fur eine einstellbare Zeit die jeweilige Slavesteckdose ein bzw ausgeschaltet werden Die Schaltzustande werden in der Webseite genau wie bei der Steck dosenleiste ber die Leuchtdioden angezeigt to control your world 7 Benutzerhandbuch PM 211 MIP Hinweis Bedienung ber WAP mit dem Handy Rufen Sie ber Ihr Handy die IP Adresse Ihres Handys mit dem folgenden Zusatz auf http Ip Nummer wap Sie k nnen sich jetzt wie gewohnt auf Ihrem Handy anmelden und jede Steckdose schalten Mit NC verbleibt die Steckdose im aktu ellen Zustand Mit On wird sie ein und mit Off ausgeschaltet Um diese Funktion nutzen zu k nnen m ssen Sie daf r sorgen dass Ihre Steckdosenleiste eine offizielle IP Nummer erh lt oder dass Ihr DSL Router mittels Dynamic Name Service einen eindeutigen Namen hat und Anfragen auf dem Port 80 frei einstellbar an Ihre Steck dose weitergeleitet werden INFRATEC Manual de usuario PM 211 MIP Restablecer la configuracion de fabrica Para reasignar toda la configuraci n a sus valores de f brica se tiene que pulsar el bot n Reset hasta que se visualice que los indica
6. usuario PM 211 MIP Visualizador de estado operativo Bot n Reset reinicio Funci n maestra control giratorio Power Masterlevel Master Slave 1 INFRATEC Conexion de red ae seme maan me Indicador de conexi n de red Indicador de tr fico de red Indicador Master maestro Indicador Slave 1 esclavo 1 Indicador Slave 2 esclavo 2 Conector Master maestro Conector Slave esclavo par 1 ee ee e 8 ee ae 8 a 8 Conector Slave esclavo par 2 Funcion Master Slave maestro esclavo La funci n maestro esclavo permite la conmutaci n simult nea de todos los dispositivos consumidores conectados a la l nea de conectores mediante la conmutaci n del consumidor conectado al conector maestro Por ejemplo todo un sistema de ordenadores con perif ricos se puede conmutar mediante la simple activaci n del interruptor del monitor El punto de conmutaci n se puede ajustar mediante el control giratorio 3 El punto de conmutaci n deber a seleccionarse de manera que el dispositivo consumidor del conector maestro siempre se pase de la raya de un modo seguro Precauci n Para configurarlo seguir estas indicaciones Antes de realizar Encienda el master y despu s lentamente gire el controlador hasta la configuraci n que llega al punto de conmutaci n y el indicador maestro 7 se quite o apague extingue Ahora gire lentamente en la direcci n opuesta de manera todos los disposi que el indicador ma
7. 1 MIP Benutzerhandbuch PM 211 MIP Werkseinstellungen wiederherstellen Zum R cksetzen aller Einstellungen muss der Reset solange bet tigt werden bis die Anzeigen 7 8 und 9 gemeinsam aufleuchten und wieder erl schen Die Werkseinstellungen der Steckdosenleiste IPNummer 192 168 000 211 Gateway l 192 168 000 254 Netzmaske 255 255 255 000 Klasse C Netzwerk Login admin Passwort admin Netzwerkanschluss Der Netzwerkanschluss erfolgt ber ein handels bliches Patchkabel der Verbindungsstatus wird ber die Leuchtdiode 5 angezeigt Der Netzwerkverkehr wird ber die Leuchtdiode 6 angezeigt Zum Einstellen der Netzwerkparameter gehen Sie wie folgt vor Verbinden Sie die Steckdosenleiste mittels eines Patchkabels mit Ihrem Netzwerk Stellen Sie auf Ihrem PC eine IP Nummer ein wel che im gleichen Netzwerkbereich wie die der Steckdosenleiste liegt siehe Werkseinstellungen u a Zum Beispiel 192 168 0 1 PM211 MIP V1 00 Login Operaci n mediante WAP con un tel fono m vil Aktivieren Sie auf Ihrem PC den Internet browser und gehen auf folgende Webseite SO ea Desde su tel fono m vil llame a la direcci n IP de su tel fono m vil http 192 168 0 211 con el siguiente agregado http Ip Nummer lwap Melden Sie sich als Benutzer admin mit dem Ahora se puede registrar normalmente con su tel fono m vil y con Passwort admin an PM211 MIP Network Settings mutar cada uno de los conectores Con
8. 5 255 255 000 class C network Login admin Password admin Network connection The network connection is established via a commercially available patch cable the connection status is indicated via the LED Net work traffic is indicated via LED 6 To set the network parameters proceed as follows Use a patch cable to connect the socket strip to your network Set an IP number on your PC that is in the same network range as the socket strip see factory settings For example 192 168 0 1 Activate the Internet browser on your PC and go to the following web site PM211 MIP V1 00 Login Operation via WAP with the mobile phone http 192 168 0 211 Logon on as user admin with the password Username INN From your mobile phone call the IP address of your mobile phone admin with the following addition http Ip Nummer wap In the Network menu you can now set the You can now register with your mobile phone in the normal way and IP number you require To adopt the data you PM211 MIP Network Settings switch each socket With NC the socket retains its current status have to reboot the socket strip Lae and it is switched on and off with On and Off respectively Dee When you have set the IP number you can re IP Address Note To be able to use this function you have to ensure that the socket store your PC to the original settings FERN strip has on official IP number or that your DSL router has been g
9. PM 211 MIP Benutzerhandbuch User Manual Manual de usuario EN IN INFRATEC Infratec AG Werner von Siemens Stra e 7 D 64625 Bensheim Germany 49 0 6251 8405 0 49 0 6251 8405 99 info infratecag de www infratec ag de INFRATEC 1613_788_13916_82_7993986927 Benutzerhandbuch PM 211 MIP Urheberrecht Alle Rechte an diesem Benutzerhandbuch liegen bei der Infratec AG Bensheim Wiedergabe und Nachdruck auch von Teilen dieses Hand buches sind nur mit Quellenangabe gestattet Haftung Die Infratec AG Bensheim bietet auf alle mechanischen und elek trischen Komponenten eine Garantie von 24 Monaten Entsorgung Die Infratec AG hat eine EAR Nummer Elektro Altger te Register beantragt diese wird in K rze nachgereicht INFRATECX Datos tecnicos Ancho Altura Longitud Peso Energia de entrada Voltaje Conexi n a red Tipo de conexi n Salida principal Salida esclava por par Corriente total m xima Modo de interrupci n Funciones de interrupci n Aprobaci n Manual de usuario PM 211 MIP 55 mm 55 mm 600 mm 1 5 kg 1 5 VA 85 250 V AC 10 Mbit RJ 45 dependiendo de la versi n enchufe con contacto a tierra 1 5 m max 16 amperios max 8 amperios 16 amperios un polo WEB WAP ce 1 Tipo de conexi n difiere segun la version PM 211 MIP tana rnnTt rn WPT yo mrirn to control your world PM 2 TEMIR PM 211 MIP 2 31 Manual de usuario PM 211
10. as Hilfe a gt m E E A gt http 217 113 176 157 PM T up o _ Kostenlose Hotmail _ Links anpassen Windows Media Lj Windows Outlets Network Update Logout PM211 MIP Update Current software version Y1 00 File to upload MOS Durchsuchen Press Moteles Mia lol Software update To transfer new operating system software you first have to down load the necessary update file from the Internet site of Infratec AG onto your computer Then log onto your socket strip with your Internet browser in the usual manner and select the Update area from the menu When you have localized the update file on your hard disk start the actual update process with the Press button 20 INFRATEC User Manual PM 211 MIP The socket strip at a glance Remote power for the home office Infratec PM 211 MIP socket strip for switching small computer environments The PM211 MIP has an Ethernet interface and can thus be connected to any normal switch or DSL router It is controlled via an integrated web server that enables the intuitive configuration of all switching functions as well as the administration of several users with dif ferent access rights The IP address for the socket strip can have a fixed configuration or it can be used dynamically via a DHCP server In addition to a master output the PM 211 MIP also has two slave connections each with two sockets Thanks to this configuration it is possible to swit
11. ch the computer on and off via the Internet and it also facilitates switching when actually in the office If for example the monitor is switched on the socket strip recognises the consum ers that are switched on and automatically supplies the devices con nected to the slave connections with power In the event of a power failure the PM 211 MIP notes the last switching status of the connections and switches the consumers on accordingly as soon as the power supply is up and running again For each slave it is possible to connect consumers with a power consumption of up to 5 amps The socket strip itself consumes less than 1 5 Watts to control your world 13 User Manual PM 211 MIP Reset button Master indicator Slave 1 indicator Slave 2 indicator Master socket Slave socket pair 1 000000900065 a 8 Slave socket pair 2 Caution Before setting remove or switch off all consumers on the slave sockets 14 Rotary control master function Network connection indicator Network traffic indicator Display for operational readiness Power Masterlevel Master Slave 1 INFRATEC Network connection seme maan me The master slave function The master slave function enables the simultaneous switching of all consumers connected to the socket strip by switching the consumer connected to the master socket For example an entire PC system with peripherals can be switched by activating the monitor switch alone
12. d Passwort festgelegt wer den Zus tzlich kann der Zugriff auf die Slavedosen eingeschr nkt werden 6 INFRATEC Manual de usuario PM 211 MIP Outlets Network Logout PM 211 MIP Outlets Master Slavei O Slave 2 So Master Operacion mediante la World Wide Web En la m scara de operaci n cada esclavo se puede activar o desactivar Adem s el bot n Pulse se puede usar para conmutar el conector esclavo respectivo una cantidad espec fica de tiempo Los estados de conmutaci n se visualizan en el sitio Web me diante los LED exactamente de la misma forma que en la linea de conectores to control your world 27 Manual de usuario PM 211 MIP Mozilla Firefox Datei Bearbeiten Ansicht Gehe Lesezeichen Extras Hilfe z E gt gt E amp A http 1217 113 176 157 PM T fus u u L3 Kostenlose Hotmail E Links anpassen windows Media 3 Windows SHEE RAP Power Outlets Network User Update Logout PM211 MIP User Settings Allowed Outlet t Administraci n de usuario En la administraci n de usuario se pueden configurar dos clases de usuarios De f brica vienen predefinidos tres usuarios admin user1 y user2 El los valores de configuraci n de f brica las con trase as de estos usuarios coinciden con el propio nombre de cada usuario Para cada usuario se puede establecer un nombre y una contrase a Adem s se puede limitar el acceso a los conectores
13. dores 7 y O se encienden simult neamente y despu s se apagan otra vez La configuraci n de f brica de la l nea de conectores es la siguiente N mero de IP 192 168 000 211 Gateway 192 168 000 254 M scara 255 255 255 000 red clase C Login admin Password admin Conexi n de red La conexi n de red se establece mediante un cable patch disponible en los comercios el estado de la conexi n se indica mediante el LED 5 El tr fico de la red se indica mediante el LED 6 Para configurar los par metros de red se deben seguir estos pasos Utilizar un cable patch para conectar la l nea de conectores a su red Configurar un n mero IP en su ordenador que sea del mismo rango de red como la l nea de conectores v anse los valores de configura ci n de f brica Por ejemplo 192 168 0 1 Activar el navegador de Internet de su ordena dor y dir jase al siguiente sitio web http 192 168 0 211 Inicie la sesi n con el usuario admin y con la contrase a admin En el men Network red ahora podr esta blecer el n mero IP que requiera Para utilizar estos datos tendr que reiniciar la l nea de conectores PM211 MIP V1 00 Login Username O 217 113 176 157 IP A Cuando se ha establecido el numero IP puede restablecer su ordenador a la configuracion original reboot to control your world PM211 MIP Network Settings Pad211 MIP Device Name a Us JE F 25 Manual de
14. e f r die Steckdosenleiste l sst sich fest kon figurieren oder dynamisch ber einen DHCP Server vergeben Neben einem Masterausgang besitzt die PM 211 MIP zwei doppelt ausge f hrte Slave Anschl sse Diese Konfiguration erlaubt das Ein und Ausschalten des Computers ber das Internet sie erleichtert aber auch das Schalten wenn man zu Hause ist Wird beispielsweise der Monitor angeschaltet erkennt die Steckdosenleiste den eingeschal teten Verbraucher und schaltet automatisch die an den Slave Dosen angeschlossenen Ger te ein Im Fall eines Stromausfalls merkt sich die PM 211 MIP den letzten Schaltzustand der Anschl sse und schaltet die Verbraucher entspre chend ein sobald das Stromnetz wieder verf gbar ist Pro Anschluss lassen sich Verbraucher mit einer Leistungsaufnahme von bis zu 5 Ampere schalten die Steckdosenleiste selbst hat eine Leistungsauf nahme von weniger als 1 5 Watt to control your world 3 Benutzerhandbuch PM 211 MIP Manual de usuario PM 211 MIP Operaci n desde la linea de comandos D Anzeige f r Betriebsbereitschaft Reset Taster La linea de conectores se puede operar tambien mediante un pro Drehregler Masterfunktion grama desde la l nea de comandos Para esto se dispone de estos a gam Po INFRATEC i comandos Netzwerkanschluss ea httpget exe est disponible en Internet como una opci n 5 Anzeige Netzwerkverbindung Anzeige Netzwerkverkehr Anzeige Slave 1 uso http ip sw u user a
15. ere einpolig WEB WAP ce 1 Die Anschlussart unterscheidet sich je nach Ausf hrung PM 211 MIP tana rnnTt rn WT mrir to control your world PM 211 MIP 1 PM 211 MIP 2 11 User Manual PM 211 MIP 12 Copyright Infratec AG Bensheim owns all rights to this user manual Reproduc tion and reprinting of this manual either in full or in part shall only be permitted with full reference to the source Liability Infratec AG Bensheim offers a 24 month guarantee on all mechani cal and electrical components Disposal Infratec AG has applied for an EAR Elektro Altger te Register Ger man foundation for Waste Electrical Appliances Register number which will be issued soon INFRATEC Technical data Width Height Length Weight Power input Voltage Network connection Type of connection Master output Slave output per pair Maximum total current Switching mode Switching functions Approval PM 211 MIP tana rnnTt rn WT mrir to control your world User Manual PM 211 MIP 55 mm 55 mm 600 mm 1 5 kg 1 5 VA 85 250 V AC 10 Mbit RJ 45 version dependent see below connector cable with powerplug 1 5 m included max 16 amps max 8 amps 16 amps single pole WEB WAP CE 1 Type of connection differs according to version PM 2 TEMIR PM 211 MIP 2 21 User Manual PM 211 MIP Mozilla Firefox Datei Bearbeiten Ansicht Gehe Lesezeichen Extr
16. estro 7 se enciende nuevamente tivos consumido Ahora haga el favor que comprobar varias veces el funcionamiento res conectados Si el indicador maestro se enciende cada vez que se conecta el dis a los conectores positivo consumidor del conector maestro entonces la configuraci n esclavos se puede considerar totalmente satisfactoria 24 INFRATEC Benutzerhandbuch PM 211 MIP Bedienung ber die Kommandozeile Die Steckdosenleiste kann auch ber ein Kommandozeilenprogramm gesteuert werden Hierzu sind folgende Befehle vorhanden httpget exe ist optional im Internet erh ltlich usage http ip sw u user amp p passwd amp o n amp f func or http ip sw s 0 ip ipaddress user username passwd password n outletnumber to switch func on off pulse toggle 25 0 read status to control your world 9 Benutzerhandbuch PM 211 MIP Mozilla Firefox Datei Bearbeiten Ansicht Gehe Lesezeichen Extras Hilfe a gt E ES A X http 217 113 176 157 PM T up Kostenlose Hotmail Links anpassen Windows Media Windows Power Outlets Network User Update Logout PM211 MIP Update Current software version Y1 00 File to upload MOS Durchsuchen Press RM MO 6 ef 0 Mia l a Softwareupdate Zum Aufspielen einer neuen Betriebssystem Software mussen Sie zu erst die notwendige Update Datei von der Internetseite der Infratec AG auf Ihren Computer herunterladen Melden Sie sich danach wie gewohn
17. iven so a clear name by the Dynamic Name Service and that enquiries on port 80 freely adjustable are forwarded to your socket reboot 18 INFRATECX to control your world 15 User Manual PM 211 MIP Mozilla Firefox Datei Bearbeiten Ansicht Gehe Lesezeichen Extras Hilfe da gt B CO gt http 217 113 176 157 PMT us L3 Kostenlose Hotmail E Links anpassen windows Media 3 Windows PAPEL Power gt _ AM Qutlets Network User Update Logout PM211 MIP User Settings MESA admin usere Password ea Allowed Outlets t User administration Two different users can be set up in the user administration Three pre defined users are already set up in the factory settings admin userl and user2 The passwords in the factory settings are iden tical to the user names A name and password can be set up for each user In addition access to the slave sockets can be restricted 16 INFRATEC User Manual PM 211 MIP PM 211 MIP Outlets Master Slavei O Slave 2 So Master Yo Slave 1 Pulse Operation via the World Wide Web In the operating mask each slave can be switched on and off In addition the Pulse button can be used to switch the respective Slave socket on or off for a specific amount of time The switching statuses are displayed on the web site via the LEDs in exactly the same way as on the socket strip 17 to control your world
18. mp p passwd amp o n amp f func 9 Anzeige Slave 2 O http ip sw s 0 Mastersteckdose AD Slavesteckdosenpaar 1 l l ip direccion IP Slavesteckdosenpaar 2 user nombre de usuario passwd contrasena n n mero de salida que se conmuta func on Die Master Slave Funktion off Die Master Slave Funktion ermoglicht alle an der Steckdosenleiste pulse angeschlossenen Verbraucher gleichzeitig zu schalten indem der an toggle der Master Steckdose angeschlossene Verbraucher geschaltet wird Beispielsweise kann ein PC System mit Peripherie komplett ange schaltet werden indem nur der Schalter des Monitors betatigt wird 75 0 read status Der Schaltpunkt kann mittels des Drehreglers 3 eingestellt werden Der Schaltpunkt sollte so gewahlt werden dass der Verbraucher an der Master Steckdose diesen immer sicher berschreitet Zum Einstellen gehen Sie wie folgt vor Achtung Man schaltet den Master ein und verdreht nun den Regler langsam Alle Verbraucher bis man den Schaltpunkt erreicht bei dem die Master Anzeige an den Slave erlischt Nun wieder ein kleines St ck in die entgegengesetzte Rich Steckdosen vor tung damit die Master Anzeige 7 wieder aufleuchtet der Einstellung Die Funktion nun bitte mehrmals testen Leuchtet die Master Anzei entfernen oder ge nun immer wenn auch der Verbraucher an der Master Steckdose ausschalten schaltet so ist die Einstellung beendet 4 INFRATEC to control your world 29 Manual de usuario PM 21
19. t mit Ihrem Internetbrowser bel Ihrer Steckdosenleiste an und wahlen dann den Bereich Update aus dem Menu aus Nachdem Sie die Update Datei auf Ihrer Festplatte lokalisiert ha ben starten Sie den tatsachlichen Update Vorgang mit dem Knopf Press 10 INFRATEC Manual de usuario PM 211 MIP El conector de un vistazo Control remoto de energ a para su oficina en casa Linea de conectores Infratec PM 211 MIP para entorno de ordenadores personales conmutables PM 211 MIP tiene una interfaz Ethernet y por lo tanto se puede conectar a cualquier conmutador normal o enrutador DSL Est controlado mediante un servidor web integrado que permite la configuraci n intuitiva de todas las funciones de conmutaci n as como tambi n la administraci n de m ltiples usuarios con diferentes derechos de acceso La direcci n IP de la l nea de conectores puede tener una configuraci n fija o se puede ejecutar din micamente por medio de un servidor DHCP Adem s de la salida maestra PM 211 MIP tambi n posee dos conexiones esclavas cada una de ellas con dos conectores Gracias a esta configuraci n es posible encender y apagar el ordenador mediante Internet y tambi n facilita la conmu taci n cuando se est en la oficina Si por ejemplo encendemos el monitor la l nea de conectores reconoce los consumidores que est n conectados y suministra energ a autom ticamente a los dispositivos conectados a las conexiones esclavas
Download Pdf Manuals
Related Search
Related Contents
Digital Housing #6146.12 Instruction Manual MOTION CONTROL Antec Gain Réflexions sur l`avenir de la Wallonie Samsung 740NPLUS 用户手册 Electrolux GA3 User's Manual Philips 42PFL7432D 42" LCD integrated digital flat HDTV avalon-uk-17 avalon-au-17 avalon-ca-17 avalon-eu-45 Freedom Server V3.3 User Manual Copyright © All rights reserved.