Home
User Manual TFT-Configurator - WS
Contents
1. SCHAEFER GmbH Winterlinger Str 4 72488 Sigmaringen Germany Phone 49 7571 722 0 Fax 49 7571 722 99 info ws schaefer de www ws schaefer de Support If you have any questions regarding this product please contact Phone 49 7571 722 51 Fax 49 7571 722 99 Copyright Duplication copy print microfilm or any other form as well as electronic spreading of this document is only permitted after formal written consent of SCHAEFER GmbH SCHAEFER GmbH reserves the right to carry out alterations of technical details wit hout prior notice For all transactions our General Conditions of Sale and Delivery shall be applicable All rights reserved Ress 013722 Revision 2010 09 16 User Manual TFT Configurator Index 5 1 9 2 5 3 5 4 5 5 7 1 72 7 3 7 4 FIPSE SECS sereno torito 4 Starting the program unesennennnnnennnnnennn 5 Loading a project uneesnnsennnnnnennnnnnnennnnnn 6 Basie SELUMOS sisi tias 7 PArameler notas 7 FIOOTS ratio ren 7 GLOCK see see ee 8 Special displays csccecscsecessesesessesessesesssseeeeseees 9 FOOY SCH NOS see 10 Floor information aenssseseneeneennnnnnnnnennnnnennenen 11 Deleting the data on the display 12 Configuration procedure secesecseceseeeeeees 13 Contacting the display nennen 13 CNEEKS ee 13 CG TUN UOI seurarapenccare aletas 14 Configuration completed 14 Creating a new project cseseeessseees 15 1 First steps In order to
2. 14 46 Y pate nn Format Xx fo Ay f 3 Color style smani Format 07 09 2010 gt Colour Apply Search Week a y f0 4 WW 170 J H 35 Accept Style Picture F Pic IM MAELEKT oftwaret Browse Apply RIKIS Temperature x 20 Y 20 Color Style None Format Centigrade Apply starting point size of the image none small medium large Here the size can be defined format of time date colour of time date This loads the weekday images transfer the data to the display 5 3 Special displays and arrows 5 3 Special displays and arrows On the Special t Arrows tab the special displays and arrows can be defined Parameter Floor settings Floors Slide Foor info Arrow x 120 v 38 w 1160 H 1132 lt Style Animation 10 Interral 01s Runinput fiF B5 1 Pic ME LEKTRIKSoftwaretoolsi lw MAE LEKTRIKSoftwaretoolsi E _ r xb vb a Warning xls vfs Y wiees I Hf zo 4 Pic IMIELEKTRIKiSoftwaretoo si Style Normal WA option Normal BKL control always on y Arrow amp Warning Clock amp Temperature Browse Browse Browse Browse Apply Browse Apply X Y W H Style Time Travel Search starting point size of the image Normal The arrows are not animated Animation XX The arrows are animated The number of th
3. hand corner The actual position is specified with the X Y coordinates With the floor information the arrows and the special displays several displays are saved on a single background The first image is in the top left hand corner the second image to the right of it If a third image does not fit into this row the process continues with the next row The next background is used If no second image fits SCHAEFER SCHADFER OmbH Winterfisger Str 4 72408 Sipma Sigmaringen Germany The top left hand image is displayed if no special signal is present Up to four special signals and one logo can be positioned here 15 16 If a display is to be used vertically images that have been rotated by 270 must be loaded AEFER SCHAEFER Gendt Winterfinger Str 4 72488 Sigmaringen Germany LJ E cn gt L e With vertical displays no date time or tempera ture can be shown these settings must be confi gured with None e Not all displays are designed for all functions None must be configured here in the settings The project can be saved once all data has been generated A TFT Configurator 2 0 22 07 2010 Parameter Arrow amp Waring Clock amp Temperature English Floorsettings FioorsStide Foorinto x 308 Ivo Swlaoe Su oss Style Floor Language MIELEKTRIKSofwaretoolslElevake TFTY MIELEKTRIKISofwaretoolstElevake TFT MIELERTRIFiSof
4. make oneself familiar with the TFI Confi gurator a sample project should first be loaded and a display configured with it see 2 Starting the program see 3 Loading a project see 4 Basic settings and 5 Parameters see 6 Deleting the data in the display see 7 Configuration procedure 2 Starting the program The following screen appears after starting the TFI Configurator parameter settings preview TFT Configurator v2 0 22 07 2010 E lei Parameter Y Layout language settings A Care SS ETT Floorsettings Fioorsstiae Foor into alo y 240 w 240 SH 160 Style None z input 80 81 y Protocot 7 segment onset o Filter none no Path port check basic settings 3 Del selected Apply Projectsave Projectload This allows the transfer q Total prog of individual areas of configuration data to the display if for exa mple only these areas were updated save project load project clear display transfer of all configura tion data to the display with one button a 3 Loading a project TIFT Configurator 2 0 22 07 2010 2 5 xi L Parameter Layout anguage arrow amp Warning Clock amp Temperature Preview Layout TT Floorsettings Floors suse Foor into Control x fo y 240 3 w 240 3H 150 3 Port Name Style None com input 80 81 Protocol 7 Segment Baud Rat
5. 68 arrows 69 weekdays 70 79 floor settings 80 120 floor info amp temperature If the entire memory of the display shall be deleted O to 120 must be set 7 1 Contacting of the display 7 2 Check 7 Configuration procedure 7 1 Contacting of the display The USB connection to the PC must be established first Then the keys MOD and DAT must be pressed and held At the same time the display must be con nected to the power supply The keys can be released after approx 2 sec The display is now in the configu ration mode 7 2 Check Port The appropriate COM port must be Control selected here Port Name COM1 Baud rate Here the highest value can be set normally Baud Rate 321600 Open The port must be opened prior to configuration Close The port must be closed after configuration C Open H Close Port scan Handshake If the number of the COM port is not known Option 1 Set COM1 and then click on Open the connection has been established when the square turns green Otherwise a Port error message is displayed All numbers can be tested this way Option 2 Connect a display via USB click Port scan and the asso ciated COM port will be shown in the list 13 7 3 Configuration 7 4 Configuration completed 7 3 Configuration 7 4 Configuration completed The port must be opened before configuration clo sed port is indicated by a red square an open por
6. e fazisoo gt Sex eo Fiter None C Open o Core No Path Basic setup Model _ ts 2j Del selected omg 2 Del ail Apply Using the button Load project a pre defined project gzip can be loaded of mm eg TE Send Total progress The data has now been loaded No images need to be loaded these are included in the project SITET Configurator 2 0 22 07 2010 Br 15 x Parameter r Lapout gt Language a Clock amp Temperature EPT Foorsetinos Floor Side Foor into x fo v 170 w sss H 74 By clicking the uploaded Here E Broka y clicking the uploade os Pit No ram ooo 1 MIELEETRIE SotwaretoolsElewake TFT 2 MIELEETRIE SottwareioolsElewake TETU 3 MIELEKTRAIKNSoftwaretoolstElewake TFT 4 MIELERTRIESottwaretoolsiElevake TET images you can view them in the preview area gt 5 1 Floors 4 Basic settings Type Display ID Accept 5 Parameters 5 1 Floors Brightness display type TFT 480 TFT 640 TFT 800 The brightness of the display can be ad justed here This can also be done directly on the display without PC LO dark to L9 bright not used transfer the data to the display Using the tab Floors Full images the background image the storeys and the full images for the special displays are defined Param
7. e arrow images must correspond to XX The display duration of the individual images is set here animation speed The travel pin can be defined here This loads the images X2 Y2 The starting point of the second arrow must be entered here if the up arrow and the down arrow are to be located at different positions Style Position Standby Accept Normal The four special displays are shown normally B10 B11 Two special displays are shown as full image B8 B11 All four displays are shown as full image This should always say separate from arrow Here you can select whether the display is always on or whether it Is switched on depending on a terminal transfer the data to the display 5 4 Floor settings 5 4 Floor settings Floor settings can be defined on the Floor set tab Parameter Arrow amp Warning Clock amp Temperature Fioor settings Floors Slide Foor into x fo el Y 240 w 240 H 160 Input 60 84 Protocol Binary Offset o y Fiter None y M a Del selected a Del all Apply Style Input Start Control Filter Accept starting point not relevant here size of the image not relevant here This should always read None The terminals for floors can be defined here normally BO B4 This is the image at the lowest floor The display control is set here De bouncing of the input
8. eter Arrow amp Warning Clock amp Temperature Floor settings Floor Slide Foor into x fo Y 1170 Style Floor Pic MAIELEKTRIKiSoftwaretoolsiElevake TFT X Y starting point of the floor image W H size of the floor image w 395 3 H 174 4 Background MAELEKTRIKISOftwe 1 2 MIELEKTRIKiSoftwaretoolslElevake TF TW 3 MAELEKTRIK SottwaretoolsiElevake TFTU 4 MAELEKTRIKASoftwaretoolsiElevake TFT El e Del selected Browse y Del all Apply Background this is the background image Browse Style none floor slide show Floor is normally set here as default No Path The images for the floors and the full images for the special display are listed here If full images have been defined for the special display they will be located at the last two to four positions Deletion Using the Delete button the loaded images can be deleted again m gt selected images all gt all images Search This loads the images Accept transfer the floor data to the display 5 2 Clock 5 2 Clock Time date and weekdays as well as a temperature can be defined on the Clock amp Temp tab Note that not all displays support this function see Manual TFT Hoori Sii X Y Fioor settings Floors Slide Foor into Arrow amp Waming Clock amp Temperature lt W H Timer x hbe Sy coor tyle Style Small Format
9. s can be set here transfer the data to the display 5 5 Floor information 5 5 Floor information On the Floor info tab additional floor information or floor images can be added Parameter X Y starting point Arrow amp Warning Clock amp Temperature Floor settings Floors Slide Foor info W H size of the image X 398 v fo w 402 H 355 Style None storey slideshow The trigger for the image change can be set here Style F loor Deletion The selected images can be deleted again here m gt selected images all gt all images o Path MIELEKTRIKiSoftwaretoolsiElevake TFT 81 MIELEKTRIKiSoftwaretoolsiElevake TFT 82 MAIELEKTRIKiSoftwaretoolsiElevake TFT MAIELEKTRIKi SoftwaretoolsiElevake TFT Search This loads the images Accept transfer the data to the display Y Del selected Browse a Del all Apply 12 6 Deleting the data on the display TFT Configurator 2 0 22 07 2010 Parameter Arrow amp Warming Clock amp Temperature Floor settings Floor Slide Foor into x fo E Y 240 we 240 Sufi 160 None 80 81 Protocol 7 segment Filter None Language Prior to a reconfiguration the data on the display should be cleared to make sure that no unwanted data remains on the display The numbers hereby represent the following areas 0 background 1 63 floors 64 special display 65
10. t by The Close button must be clicked when the confi a green square guration is completed The power supply of the dis play must be disconnected The USB connection can then be terminated The display can be tested with the Simulation kit TFT Configurator 2 0 22 07 2010 E o x Parameter Language Arrow amp Warning Clock amp Temperature ET floorsettings Floors slide Foorinto PAR lo Ay fz H w 240 H H fiso Port Name Style None com Input 80 81 gt Protocol 7 segment nd s21600 Offset 0 Filter None e _ Del selected _ Del selected Del all All configuration data is transferred to the display via Individual areas can be configured to the display the button Accept all with the Accept buttons These buttons are located at e Basic setting x 1 e Floor Full images tab x 1 e ClockEtTemp tab x 4 e Special amp tArrows tab x 2 e Floor set tab x 1 e Floor info tab x 2 Thus either the complete data can be transferred or only updated areas 14 Creating a new project To create a new project an already existing project can be loaded and then modified A few points must be considered here e All backgrounds must correspond to the pixel di o mensions of the TFT display For example for the TFT 800 the image must have a size of 800 x 480 pixel e All images must be positioned in the top left
11. waretools1Elewake TF TI MIELEKTRIKiSoftwaretools1Elevake TFT Da Browse All images are saved with the project so they need not be saved separately 17 18 SCHAEFER IM SCHAEFER IM