User Manual for KNOT-O-METER - smt

image

Contents

1. or reprocessed Important advice All information included in this manual was collected with great care and in the best of knowledge Mistakes however can not be completely excluded For this reason MT Mechatronic Technologies would like to let you know that no warranty apart from the agreed warranty claims any legal responsibility nor any liabilities for consequences which go back to incorrect data exist We are always grateful for any notification of malfunctions Page 5 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program Mechatronic Technologies 2 Operating the data recording program 2 1 Measuring with the data recording program 2 1 1 Starting the data recording program Connect the Knot O Meter to your laptop via the USB cable If the connection has been established successfully the Knot O Meter s LED display will light Start the program by selecting program SMT k bytes Knot O Meter Knot O Meter recording program 2 1 2 First start When the program is started for the first time following screen pops up Knot O Meter E E Sprache Language English Welcome ta the Knot O Meter Please insert the congress name and the congress location and press the start button If you wish to reset the average values etc select Start new measurement for congress YES and press the amp tart button Mame of congress
2. Pu Place of congress start new measurement for congress Welcome to the Knot O Meter Please enter your congress name and congress location and press start Should you want to reset your average levels please select Start measurements for new congress Yes and press start Page 6 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh VM JIV li a Mechatronic Technologies Running system If the program was already running before the following screen will pop up e g Knot O Meter E Sprache Language English Welcome to the Knot O Meter Please insert the congress name and the congress location and press the start button If you wish to reset the average values etc select Start new measurement for congress YES and press the Start button Mame of congress Surgery Place of congress Munich start new measurement for congress Quit C sat 7T Should the reference data from the evaluation average of the measurements so far and the standard deviations be used for the congress the program can be started by selecting no If the reference data needs resetting select yes You can end the program by selecting the Quit button Page 7 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de U
3. tec de User Manual analysis program dh amp Mechatronic Technologies The average value of all filtered measurements and the standard deviations of the whole measurement in relation to the average value of the complete measurement and not the single sensors The value of the current measure the average value and the standard deviations The percentage deviation of the current measurement from the value of the selection Prize list with the least standard deviation between single knots and selected filter criteria E q for the presenting in a diagram a Analysis Chart Challenge Knote Faszie Median of challenge Pressure in N neg standard deviation pos standard deviation Complete median ofthe measurement Diagrammbereich 1 2 3 4 5 6 7 8 9 10 i start 3 t B be 8 3 be v an window 2 knot 1 Analyse 2 en hd fra 14 00 Page 34 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual analysis program dh 2 Schnesweis SAVE ui Mechatronic Technologies 3 5 Exporting the participants data Has the analysis finished and the data should be imported into a general CSV File the button Export Data needs selecting For this the memory location fort he participants data from the analysis program and the name of the fil
4. Bi Hospital type all Surgically active lt all gt Attendance at a training ams 7 Professional experience lt all gt Bi Don t search for winner with Specialist zallz zi measurement values 10N or ON Participant s challenge Knote Faszie Number of participant s 10 Analysis se Show analysis Whole Minimal standard Percentage measurement deviation deviation Mean 1 28N D 26M 79 69 5 Standard D 8N 0 52M 35 0056 deviation Competition winner Median Std deviation Competition Surname Given_name Year of birth Challenge 1 440871 2 033605 Yes Mustermann Maria 1967 Knote Faszie Back to data management All records which were read out over the participants data can be filtered in the overview E g was the data only put in with the participant s challenge knot Faszie only this challenge can be selected Usage of the buttons Show analysis The analysis of the selected filter criteria is started and the result shows up in the area analysis Show chart The result shows up in a separate window in a diagram Back to the data management Ends analysis and returns to the overview Displayed The challenge the participant had to knot with at the same time to the selection that was filtered number of particpants knotting in the same challenge Page 33 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt
5. User Manual F SAV w Mechatronic Technologies User Manual for KNOT O METER For operating the Knot O Meter For the Knot O Meter s data recording program For the Knot O Meter s analysis program Version 2 3 01 2011 Page 1 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual Directory Contents 1 General operating instructions for the Knot O Meter ccccceeccseeeceeeeceeeeeeeeseeeeseeeseeeeseeeaes 3 1 1 maie cM u 3 1 1 1 For using the Knot O Meter software 3 1 1 2 For using a second display or 3 1 1 3 For using the analysis program sess 3 1 2 Connecting the Knot O Meter to 3 1 3 Usage of the Knot O Meter seessseesssssssseeneeeennnen nennen menn nnne nnne nnns nnns 4 14 General operating instructions 2 ia nennen utu eU xix 5 1 5 nee Unter Ufide E Enter ef nennen 5 1 6 Imprint5 2 Operating the data recording PrOoQraim ccccssecccsseccceececeucecceeeeceucecsueeeseusessaeeeseusessueessueeessaees 6 2 1 Measuring with the data recording program ccceccecsececeeeeeeeeceeeeseeeeeeeseeeeseeesaueeseeeeaes 6 2 1 1 Starting the data recording pro
6. analysis program Select the analysis program for the Knot O Meter over Program SMT k bytes Knot o meter Knot o meter analysis program The main map Data Administration analysis starting opens Es Analysis Data management Analysis program for the Knot O Meaeter Mainmenu import measured data from folder Import files Analysis Export data to a CSV file Import data from a CSV file Export data to a CSV Tfile CSV file import Soracheinstellungen Language settings Sprache Language Version 2 0 Exit program Program ends by selecting the button Exit Program Page 29 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual analysis program dh E B Schneeweis SAVE amp Mechatronic Technologies 3 1 Importing the participants data By selecting the button mport the participant s data are loaded into the analysis program For this select the folder in which the participant s data were saved Wahlen Sie den Ordner mit den zu importierenden Probandendaten 4 Corel User Files fy Downloads E Eigene Bilder HA Eigene Musik FS Eigene Scans E 1 Eigene videos E Knot O Meter The memory location for the participants data from the Knot O Meter s analysis program is C Dokumente und Einstellungen lt USER gt Eigene Dateien Knot O Meter Participants Select file and accept wit OK When files where successfully i
7. e 0 offset Sensors Sensor Senszorh live max live max live mas TUN Display sensor values in separate window Reset Start Select the item O offset calibration in the menu item Calibration Following window will appear which will point out that the sensors are not to be under pressure If this applies press Yes to confirm If no is chosen the O offset calibration will not be carried out offset calibration x with this Function you are performing an offset adjustment to all calibration values Please take care that all sensors a are nok influenced by strands or weights Do vou wank to do the 0 offset calibration now No Page 12 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh JIV E A Mechatronic Technologies If the O offset calibration has been carried out successfully the following window will pop up which is to be confirmed with OK and you will return to the window real time sensor data 0 offset calibration X 1 0 offset calibration successfully Finished 2 1 5 Input of the participants data and starting the measurements Participant data The surname given name and age boxes are not active until Attendance to the competition is Participant ID 000000 Surgery selected Attendance to the c
8. e are selected in this window Geben Sie den Namen der Datei an Speichern in E DatenExport_ o i Fir Arbeitsplatz eng Dateityp csv csv zi Abort 2 burg E g Test_Export csv To save the file select Save When files where successfully exported following message will be showed KNOT O METER Analysis ox J Export completed Select OK to return to the main menu Page 35 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual analysis program JIVR Mechatronic Technologies All values from all measurements of one participant are in the exported CSV file in a row with 32 columns containing following values 5 8 eo lo a Jr 25 04 2009 00 07 1900 1 26 04 2009 07 29 2 Maria Mustermann 1967 Max Value Max Value Max Value Max Value Max Value End Value End Value End Wert End Value End Value P arm 2 pens 3 ua 4 am 5 P 1 BE 2 u 3 mE 4 zu 5 44772 1772 004905 04905 44772 1772 7 510781 5 529273 8 688857 4 745919 9 442125 2 905269 AAA aes 4 299088 o rem s wil x y Average of Standard Attendance the End Deviation of Congress Place to Gender Suture Surgeon P Values the End Competition material active Values Professional a C Participant s type of Attendance at a experience Specialist Qualification Subdiscipline eine tra
9. e basic idea of the Knot O Meter is to achieve most consistent knots on the Knot O Meter and it s possible to arrange a competition with the included data recording software There is no study which force is the best for each tissue layer Accuracy 0 5 N Only use in internal locations Operating temperature Ambient temperature 15 25 C Storage temperature Ambient temperature 10 35 C Don t expose to high temperature fluctuations e g take care of solar beams Operating during adverse ambient conditions is not allowed E g e Wet and too high air humidity e Dust and flammable gases fumes or solvents Do not twist or put high pressure onto the silicon measuring pads otherwise the measuring sensors might get damaged BEWARE OF FORCES ON THE SILICONPADS DURING TRANSPORTATION 1 5 Maintenance If the silicone pads show any kind of wear and tear send back the Knot O Meter to the manufacturer for replacing it The Knot O Meter should be calibrated every 2 years For calibrating the sensors please get in contact with the manufacturer 1 6 Imprint Operating instructions MT Knot O Meter Issue 1 0 E Issuing date January 2010 MT Mechatronic Technologies Sonnenwiechser Str 23 D 83052 Bruckmuehl Germany All rights reserved No duplicates in any form photocopy print microfilm or through any other process without an explicit written permission from MT Mechatronic Technologies are allowed to be produced
10. e table By selecting No the already existing calibration table will be used If the import of the table with the calibration values was successful all sensors without pressure show ON Page 21 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program Schneeweis Mechatronic Technologies Realtime sensordata Page 22 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh JIV E A Mechatronic Technologies 2 2 2 Importing the selection file for the participants data If a new changed XML File selection list for participants was already created on another PC the file can be used by importing the recording program so the measuring station offers the same selection The calling screen for the import is the online display window real time sensor data Realtime sensordata File Calibration Info Sensorl Sensor Sensors Sensor Sensors max live max live max live max live max live oo os cM p EN Eu lt C MENSES iF v Display sensor values in separate window By selecting Settings Import the following selection window search for files is activated Page 23 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt
11. ediatric surgery others n a not applicable No training Skill training Knot training Fixatin valve Knotting fascia Knotting liver Knotting enteroanastomosis Knotting with 1 N Knotting with 5 N Knotting with 9 N The participant s information can be edited in the file ProbandSelections xml located in the folder c Dokumente und Einstellungen lt USER gt Eigene Dateien Knot O Meter en Important Don t change the participant challenge Fixatin valve Knotting fascia Knotting liver Knotting enteroanastomosis Knotting with 1 N Knotting with 5 N Knotting with 9 N If you change this it is not possible to get the correct statistic data Page 14 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh VM DAV li a Mechatronic Technologies 2 1 5 2 Example for adding the suture material Prolene 2 0 Close the recording program Open file ProbandSelections xml with an editor not with double click and go to lt SeamMaterial gt P ProbandSelections xml Editor Ioj x Datei Bearbeiten Format Ansicht 7 lt otdDeviation O lt StdDeviation gt gt lt NumberOMeasurements 0 lt NumberOttleasurements gt lTask gt lt 5 gt lt gt lt string U 1 year lt string gt lt string 1 5 years lt string gt lt string 5 10 years lt string gt lt string gt 10 S0 years lt s
12. essage will be showed KNOT O METER Analysis E xl 1 1 Files where succesfully imported Return to the main map with OK If a participant already exists in one or more databases from which the data is to be imported indicates this by showing the data name in a pop up which must be accepted by selecting OK KNOT O METER Analysis 1 The data of following Files exists inside the database already 255 10 24 1 2010 21 53 32 csv Page 31 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual analysis program dh Po amp Mechatronic Technologies 3 3 Select language With the button Sprache Language the language German English can be chosen Es Sprache Language p Sprache w hlen Choose language English Okay Abbruch Cancel Chose language in the list and accept with Okay Page 32 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual analysis program CA E Mechatronic Technologies 3 4 Analysing the participants data By selecting the button Show analysis the import of the analysis data is started Analysis ex d Filter criteria for the analysis Name of congress Chirurgie 7 Date all gt Gender lt all gt Qualification lt all gt Bi Suture material zallz Subdiscipline lt all gt Bi Decor all
13. g gt Trauma surgery lt string gt P ProbandSelections xml Editor Ioj x Datei Bearbeiten Format Ansicht 7 lt gt a lt string U 1 year lt string gt lt string 1 5 years lt string gt lt string 5 10 years lt string gt zstringz 10 30 years lt string gt zstringz3l and more years lt string gt Experlence gt Sseamllaterial gt lt string gt Prolene 2 0 lt string gt lt string Monocryl 4U lt string gt lt string gt Prolene 4 U lt string gt lt string gt icryl lt string gt lt string gt Ethibond lt string gt lt Seambvlaterial gt evellfEducatian gt lt strindg gt amt String gt lt string gt Senlor physiclans string gt lt string Chief surgeon string gt lt string gt others lt string gt lt LevelltEducation gt When the name is changed save the file You can see the new information after a new start of the program Page 16 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh m JIV li Mechatronic Technologies 2 1 5 3 Start measurement By pressing Start measurements the measuring of the participants begins The window Measurement running will pop up and the participant can start knotting Measurement running Measurement progress e The measuring results can not be seen online during the knotting process to avoid influences on
14. gether with the Knot O Meter The calling screen for importing is the online display window real time sensor data Realtime sensordata Calibratic Info Sensorl Sensor Sensors Sensor Sensors max live max live mas live max live max live 10 File oN Display sensor values in separate window Reset Quit Start Page 20 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh E B Schneeweis SAVE amp Mechatronic Technologies Through settings Import following screen will appear search file je 2 Neuer Ordner 91 425 Platine 4 Protokolle na ID ScreenShots Software Se E um Doku 81 425 Ordner Test ProbandenDaten 425 SW Check Abbrechen A Select files in which the calibration data have been saved e g data export_AT Accept with OK If the data has successfully been imported following message will pop up LS 5 1 Files were exported successfully Press OK to return to the online display window real time data If a calibration table already exists the message will ask if the existing table should be overwritten overwrite i x j The flecti Dokumente und EinstellungenimarkusiEigene Dateien Knot O Meter Settings 1 calibalready exists Do you want Eo overwrite Yes No Select Yes to use th
15. gram seesssessssesssseeeneeen nennen enne 6 NEM aliu NE E EE E E E E 6 2 123 VY PEN 8 2 1 4 Calibrating the O offest on the sensor 222u002240022000 nenn onennnnnnnenenne nenn enennennnn 12 2 1 5 Input of the participants data and starting the measurements 13 2 16 Measurement SSUES po YEN DEOPREGEDEO EOE ee 18 2 2 Importing Exporting calibration data and settings for the participants data to another PC20 2 2 1 Importing the calibration data cccccccscccsscccececeeccceeeceueeseeeecseeceueesseesseeessueeseeesaaes 20 2 2 2 Importing the selection file for the participants data 23 2 2 3 Exporting the calibration files and the XML File for the participants information SSIS CHONG een ee 25 23 Trouble RN Rt 27 3 Operating the analysis PFOQKAM ccccccccsecccseeccececuecceeeceuceseeeceeeceueeseeessueesseeesueesseeesseesseeens 29 3 1 importing Mme ez UR RETRO eee 30 3 2 Importing the participants data from a CSV File 31 33 CLO CL A cie 32 3 4 Analysing the participants data 33 3 5 EXDOMING the par ciparits en 35 Page 2 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt
16. ining Basic and regular u Knot 0 1 years yes Assistant Hand surgery medical care no training Enteroanastomosis Basic and regular 0 1 years no Assistant Andere medical care No training Knot Fascia Important If in one table element is displayed nu not used this particular setting were not used by the participant Participant s challenge Page 36 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de
17. knots made on the sensors the real time display could look like the following example Realtime sensordata TH File Calibration Settings Info Sensor Sensor Sensors Senzord Sensors mak live max live mas live max live max le LS COLL 1014 EM cd MES DE _ IN m Display sensor values in separate window Reset LE uil Stark Page 10 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh 4 u Schneeweis Display in a separate window Realtime sensordata Sensor Sensor Sensors sensor Sensor max lve le live Ive lve ma 10 Page 11 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh M JIV li a Mechatronic Technologies 2 1 4 Calibrating the O offest on the sensor Under the menu item calibration calibrate O offset of all sensors can be set back to zero This is need when the ambient temperature of the device defers to the original temperature during calibration This could be necessary during the operation of the device in a day Important If this function is carried out it must be made sure that all sensors have no pressure on them Realtime sensordata File Calibration Info Settings edit Calibrat
18. led correctly The program will exit Corrective action End program connect Knot O Meter restart program e Online Display window real time Sensor Data shows no values although the calibration of the device was done Realtime sensordata _ File Calibration Settings Info Sensor Sensor Sensors Senzord Sensors mak live max live mas live max live max live 104 oh LUN FM 23 Fi Display sensor values in separate window Reset E uil Stark Corrective action check settings of the Redlab Cards Page 27 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh y Schneeweis SAVE amp Mechatronic Technologies Start Redlab Program InstaCal and double click on Board 0 USB 1208LS serial 210 Instat al File Install Calibrate Test Help WE rc Board List E tub Universal Serial Bus In the window Board Configuration in the pick box No Of Channels 8 Single Ended has to be selected Board Configuration i L LISB 1208L5 Factory Serial 1400087 Custom Seral Ma 21 0 of Channels Flash LED Firmware Version 1 00 Page 28 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual analysis program dh JIV li Mechatronic Technologies 3 Operating the
19. mported following message will be showed KNOT D METER Analysis x 1 1 Files where succesfully imported Return to the main map with OK If a participant already exists in one or more databases from which the data is to be imported indicates this by showing the data name in a pop up which must be accepted by selecting OK KNOT O METER Analysis X The data of Following Files exists inside the database already 255 10 24 1 2010 21 53 32 csv Page 30 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual analysis program ch E Y Schneeweis SAV Mechatronic Technologies 3 2 Importing the participants data from a CSV File By selecting the button CSV file import the participant s data are loaded into the analysis programme Select the folder in which the participant s data were saved ffnen 0 4 Suchen in G Test Esport it p m Zuletzt verwendete D Desktop Eigene Dateien gr Arbeitsplatz ig Dateiname est Export cey Lx Metzwerkumge Dateityp csv csv csv Abort burg Schreibgeschiitzt ffnen 2 The memory location for the participants data from the Knot O Meter s analysis programme is C Dokumente und Einstellungen c USER Eigene DateienKnot O Meter Participants Select file and accept wit OK When files where successfully imported following m
20. ompetition Yes Given name 5 urnarne fear of Birth ustermarin 2003 EL ual f cation 5 ubdiscipline ype of Clinic Attendance at training Participant s challenge Do challenge without participant s data cane gt vol Item 1 Measurement without participant data can be chosen with the checkbox Do challenge without participant s data In the participant s data now will be saved nu not used Item 2 Participant data can be selected and or deactivated in any needed constellation When checking out one of the data nu not used will be saved Page 13 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program chneeweis Mechatronic Technologies 2 1 5 1 Following options can be selected in the list for participant s information 1 ot es qu ae 10 11 Gender Suture material Doctor Surgeon Professional experience Medical specialist Qualification Sub discipline Participant s clinic type Attendance at training Participant s challenge Male Female Monocryl 2 0 Prolene 4 0 Vicryl 1 Ethibond Yes No Yes No 0 1 years 1 5 years 5 10 years 10 30 years 30 and more years Yes No Assistant Senior physician Chief surgeon others Trauma surgery Hand surgery Visceral surgery Cardiac and vascular surgery Pa
21. ser Manual recording program dh Mechatronic Technologies 2 1 3 Online display Realtime sensordata E File Calibration Settings Info Sensor Sensor Sensors Senzord Sensors mak live mas live mas live max live max le en EM EE L ea te C BRI IN m Display sensor values in separate window The window real time sensor data is the calling screen for all further measurements All measurements can be seen here If there is no knot pressure touching the sensors no value is displayed 0 N With the button Reset Max the max value flags for all sensors will be set back to zero Quit closes the program To start the measurement of a participant press the button Start The second display window is activated for all further inputs through the option Show sensor values in separate window Page 8 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh 4 u Schneeweis Separate window realtime sensordata display Realtime sensordata Sensor Sensor Sensors sensor Sensor max lve le live Ive lve ma 10 Page 9 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program E Y Schneeweis SAVE Mechatronic Technologies Are the
22. ta Realtime sensordata EE File Calibration Info Sensor Sensor Sensors Senzord Sensors mak live mas live mas live max live max le eR cs z EM MEME en S CO BRIT IN m Display sensor values in separate window By selecting Settings Export the follwing selection window search for files is activated Page 25 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh E B Schneeweis SAVE A Mechatronic Technologies fe 2 Neuer Ordner 81 425 Platine Protokolle E E3 Ordner Test be ID ProbandenDaten H SW Check a u NE Abort P Select the folder in which the XML file Selections xml will be saved E g DataExport AT Accept with OK If the data has successfully been exported this message will pop up Done FE 1 Files were exported successfully Press OK to return to the online display window real time sensor data Page 26 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program E u Schneeweis DAVE a Mechatronic Technologies 2 3 Trouble shooting e Recording program was started before the Knot O Meter was connected The application could not connect with the sensor board Please check if the redlab card is connected the the camputerand if Ehe drivers were instal
23. tec de User Manual recording program dh E B Schneeweis SAVE amp Mechatronic Technologies II Neuer Ordner 9 5 Platine E ID Protokolle m Ij ScreenShots A Software C DatenExport_AT Doku He Ordner Test je PrabandenDaten 3 H SW Check mon 2 Select the folder in which the XML file Selections xml was saved E g DataExport AT Accept with OK If the data has successfully been imported this message will pop up x 1 1 Import complete Press OK to return to the online display window real time sensor data If the file ProbandSelections xml already exists the message if the file should be overwritten will appear j The flecti Dokumente und EinstellungenimarkusiEigene Dateien kKnot O MeterideiProbandSelections xmlalready exists Do vau want bo overwrite Yes No Select Yes to use the file Select No and the already existing XML file will be used further on If importing the table was successful the selection list will show the participant s changed new values Page 24 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program eh M JIV amp Mechatronic Technologies 2 2 3 Exporting the calibration files and the XML File for the participants information selection lists The calling screen for doing the exporting is the online display window real time sensor da
24. tec de www smt tec de User Manual operation JIV il Mechatronic Technologies 1 General operating instructions for the Knot O Meter 1 1 PC requirements 1 1 1 For using the Knot O Meter software e RAM memory gt 500 MB e CPU frequency gt 1 3 GHz e Operating system Windows XP min Service pack 2 Windows Vista e USB Interface e Free HDD capacity gt 500MB 1 1 2 For using a second display or beamer e Inferface for separate display e Graphic board capable for two displays 1 1 3 For using the analysis program e Microsoft Access 2007 1 2 Connecting the Knot O Meter to PC Connect the USB type B interface of the Knot o meter with included USB cable to your USB interface type A on your PC The Knot O Meter s LED display will light Page 3 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual operation 1 3 Usage of the Knot O Meter Important The knots have to be done within the red markings on the silicone pads FENOT O METER Hu Cut the string at the cut slots on each side of the silicone pads only Make sure the silicon pads do not get damaged while removing the strings Page 4 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl www smt tec de User Manual operation Mechatronic Technologies 1 4 General operating instructions Th
25. termined value of the current congress according to the challenge average value and standard deviation the value of the current measurement average value and standard deviation the percentage deviation of the current measurement of the statistically determined value of the congress Usage of the buttons Save new participant The measurement has successfully been carried out and needs saving return to online display real time sensor data Save new measurement The participant wants to start a measurement with a new challenge Return to input screen fort he participant s information to edit the input Repeat measurement The participant would like to repeat the measurement Return to the input screen without repeating the measurement Now it is possible to edit the data and start the measurement new Abort The participant and the measurement are not to be saved Return to online display real time sensor data Page 19 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh y Schneeweis DAViS Mechatronic Technologies 2 2 Importing Exporting calibration data and settings for the participants data to another PC 2 2 1 Importing the calibration data If the Knot O Meter will be used on another PC and the calibration data were not installed yet the necessary file can be imported All calibration data will be saved in the delivered CD to
26. the final knotting result As soon as the participant has finished the knots the measurement reading will end by pressing finish measurement The participant may require max 30 minutes for knotting The following appears during the participant s data input and measurement Participant data Inserting participant data Measurement running Test your Knotting Measurement in progress t Page 17 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program ch 4 B Schneeweis DAVE A Mechatronic Technologies 2 1 6 Measurement results Results of the measurement Sensori Sensors Sensors Gensor Sensoarb max live max we max live max live max we qu Challenge Knotting Fascia Number of participants 4 statistically C calculated TE Deviation value of this percent congress M m Save new ED nee gt gt In the window measurement results the final results bar as well as the max values marker of the knotting are shown Page 18 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program Mechatronic Technologies Display on the right the challenge the participant knotted with the number of participants who have knotted with this challenge the statistically de
27. tring gt lt string 30 and more years lt string gt z ExeermEca lt SeamlWaterial gt lt string Monocryl 4U lt string gt lt string gt Prolene 4 U lt string gt lt string gt icryl lt string gt lt string gt Ethiband lt string gt lt Seamaterial gt z lt string gt Assistant lt string gt lt string gt Senior physician lt string gt copy e g lt string gt Prolene 4 0 lt string gt and insert it on the first position Change the name to lt string gt Prolene 2 0 lt string gt Page 15 of 36 MT Mechatronic Technologies Sonnenwiechser Str 23 83052 Bruckm hl info smt tec de www smt tec de User Manual recording program dh S JIV li i Mechatronic Technologies F ProbandSelections xml Editor O xi Datei Bearbeiten Format Ansicht lt string 1 5 years lt string gt gt lt string 5 10 years lt string gt lt string 10 50 years lt string gt lt string 30 and more years lt string gt lt Experence gt goeambhaterial lt string gt Prolene 4 0 lt string gt lt string Monocryl 2U lt string gt lt string gt Prolene 4 U lt string gt lt string gt Vicryl lt string gt lt string gt Ethibond string gt seambaterial gt lt string Assistant lt string gt lt string gt Senior physicianz string lt string gt Chief surgeon lt string gt lt string gt others string gt lt LevellfEducation gt lt opecialAraa gt lt strin