Home
User's Manual - microSYST Systemelectronic GmbH
Contents
1. microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas serse 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface Digital Outputs 6 pole Plug Connector ST12 The outputs supply 24 VDC maximum current load is 200 mA per output Pin Labeling Assignment 1 GND 2 A1 Output 1 3 GND 4 A2 Output 2 5 GND 6 A3 Output 3 Digital Inputs 7 pole Plug Connector ST13 Inputs are set via Vout with 24 VDC The common GND pin is used for the connection of initiators Pin Labeling Assignment 1 Vout 2 E1 Input 1 3 Vout 4 E2 Input 2 5 Vout 6 E3 Input 3 7 OV SD Slot ST9 Slot for commercial SD cards with up to 2 GB memory Optional interface for Profibus or Profinet interfaces of microSYST ST1 and ST3 Page 11 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de mitas ser32 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 3 2 Switches RS422 485 Bus Termination Mode DIP S5 At the first and the last device connected to a RS422 485 bus line the bus termination must be set microSYST Bus Termin
2. none 2 8 4 E even 1 7 5 E even 1 8 6 E even 2 7 7 E even 2 8 8 O odd 1 7 9 O odd 1 8 A O odd 2 7 B O odd 2 8 C z not allowed F ADR 10 Coding Switch S4 The switch sets the decade of the address ADR 1 Coding Switch S3 The switch sets the unit position of the address 3 3 Status LEDs The status LEDs of the front have the following meaning LED POWER 24VDC lights static green if the supply power 24 VDC is connected POWER 5VDC _ lights static green if the supply power 5 VDC is internally created microSYST DATA lights yellow at every received frame lights red at a faulty interface configuration FAULT for example wrong baud rate wrong parity etc microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de Page 13 microSYST mitas setse 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 4 Mounting Options 4 1 Panel Mounting Page 14 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST e00 mitas ss732 T Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 4 2 Housing 375 375 Page 15 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone
3. 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas ser32 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 4 3 Pedestal 250 210 250 210 Page 16 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas ser32 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 5 Appendix 5 1 Maintenance and Care Observe the following instructions Display quality is impaired by direct illumination with bright light sources and or direct sunlight The device must be switched off before cleaning Protect the device from excessive humidity extreme vibration direct sunlight and extreme temperatures Non observance may lead to malfunctioning or destruction of the device Under certain circum stances electrical shock fire and explosion may occur as well In formation concerning allowable ambient conditions including rec ommended temperature ranges can be found in the chapter enti tled Technical Information The control panel may not be placed into service if the device and or the power cable are known to be damaged Do not attempt to repair the device yourself The guarantee is ren dered null and void if the device is tampered with by unauthorized persons microSYST Systemelectron
4. RAL 7016 anthracite housing with pole powder coated sheet steel colour RAL 7016 anthracite see chapter Mounting Options O to 50 25 to 60 Page 4 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas ser32 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 2 1 Serial Communication All required interface parameters can be adjusted with the help of switches see chapter Connector Pin Assignments After a control frame from the Master for controlling the LEDs or text call at the LCD the control panel replies with a response frame that represents the states of the buttons 3 digital inputs and 3 digital outputs can be controlled 2 1 1 LED Button Assignment 33 34 hy POWER 24 VDC hs DATA by POWER 5 VDC bs FAULT microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de Page 5 microSYST mitas ser32 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 2 1 2 LCD Display e 2 lines with 24 characters each e white backlight e 2 buttons and for scrolling multiline messages 2 1 3 SD Card Type commercial cards up to 2 GB Formatting FAT 1024 messages storable A message can have up t
5. be considered used and that it has been purchased as is No guarantee claims may be made in such cases The General Terms and Conditions of microSYST Systemelectronic GmbH in current version apply as well Page 18 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas sers2 1 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 5 3 Versions Overview Remark Description 21 04 10 Document created 25 08 10 Additional information 21 08 12 Nickl RS485 connection assignment added DIP switch settings for RS422 485 bus termination corrected 19 03 13 Company address warranty changed 12 06 13 Description of DIP switch for mode setting 22 10 13 Logo Certified per DIN EN ISO 9001 Page 19 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de
6. 6 Line8 2 1 5 Starting Procedure The display shows a starting message with the version number and the inter face parameters Page 6 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de D1 D2 D3 D4 DS D6 microSYST mitas serse 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 2 1 6 Control Frame Frame Structure ADR D1 D2 D3 D4 D5 D6 CHK Address of the Data bytes according to the following Checksum BBT32 table XOR combination of all 7 bytes ADR XOR D1 XOR D2 XOR D3 XOR D4 XOR D5 XOR D6 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 LED 8 LED 7 LED 6 LED 5 LED 4 LED 3 LED 2 LED 1 LED 16 LED 15 LED 14 LED 13 LED 12 LED 11 LED 10 LED 9 LED 24 LED 23 LED 22 LED 21 LED 20 LED 19 LED 18 LED 17 LED 32 LED 31 LED 30 LED 29 LED 28 LED 27 LED 26 LED 25 ees bere Display ON Output 3 Output 2 Output 1 LED 34 LED 33 Message Message Message Message Message Message Message Message Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 LED A LED lights if it s corresponding bit is set Message A message is called with a number 10 bits Display ON The display is switched on if the bit is set Output An output is set with its corresponding bit Page 7 microSYST Systemelectronic G
7. ation DIP1 DIP2 DIP3 DIP4 RS422 485 set OFF OFF ON ON not set OFF OFF OFF OFF Modus DIP5 BBT32 T ON Standard setting recommended BBT32 OFF Controlling like previous version mitas RS BBT32 X M22 CB325E 001 Limitations Display and upper two buttons without function different control frame Interface DIP7 DIP8 RS422 OFF OFF RS485 ON ON Baud Rate Test Coding Switch BAUD S1 Position Function 0 1 not allowed 2 3 Baud rate 1200 Baud 4 Baud rate 3600 Baud 5 Baud rate 4800 Baud 6 Baud rate 7200 Baud 7 Baud rate 9600 Baud 8 Baud rate 19200 Baud 9 Baud rate 38400 Baud A Baud rate 57600 Baud B Baud rate 115200 Baud LED Single test C All LEDs are successively switched on and afterwards swit ched off again D Button test If a button is pressed it s corresponding LED lights up E LCD test Segment test of the LCD display F HEX switch test Position of HEX switches is shown in the display microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de Page 12 mitas ser32 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface Data Format Coding Switch SCOM S2 Position Parity Stop Bits Data Bits 0 N none 1 7 1 N none 1 8 2 N none 2 7 3 N
8. c GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas sers2 1 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 2 2 Examples All examples are valid for device address 1 Switch on LED 10 01 00 02 00 00 00 00 03 Incoming response frame 01 00 00 00 OO OO OO 01 If button 4 is pressed during the controlling you receive following response 01 08 00 00 00 00 00 09 Switch display on and show message 20 all LEDs are out 01 00 00 00 00 20 14 35 Set output 1 01 00 00 00 00 04 00 05 If input 3 is set at the same time you receive the following response 01 00 00 00 00 10 OO 11 Page 9 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas serse 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 3 Connector Pin Assignments Settings BAUD ADR 10 ADR 01 scon s2 S4 ao bal bat n a GND 24U PE PE TxD TxO RxD RxD 3 1 Connectors Power Supply Interface 8 pole Plug Connectors ST5 ST6 All pins of ST5 are connected with those of ST6 Pin Assignment Description 1 GND 5 24 VDO Power Supply 4 PE 5 Tx 6 TX Interface 7 Rx or RS422 Rx Tx or 8 Rx or RS485 Rx Tx Page 10
9. ic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de Page 17 microSYST mitas serse 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 5 2 Warranty Liability For the product liability is assumed for defects which existed at the de livery date according to our General Terms and Conditions Technically changes as well as errors are excepted A claim for delivery of a new product does not exist The buyer has to check the received product immediately and indicate evident defects at the latest 24 hours after detection Non observance of notification requirements is equated with acceptance of the defect Not immediately visible defects have to be indicated immediately after their perception too Generally defects and their symptoms must be described as accurately as possible in order to allow for reproducibility and elimination The buyer must provide for access to the relevant device and all required and or useful information at no charge and must make all of the required data and machine time available free of charge The guarantee does not cover defects which result from non observance of the prescribed conditions of use or from improper han dling If the device has been placed at the disposal of the buyer for test pur poses and has been purchased subsequent to such testing both parties agree that the product is to
10. mbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas setse 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 2 1 7 Response Frame After every control frame the BBT32 replies with a response frame Frame Structure ADR Al A2 A3 A4 A5 A6 CHK Address of the Response bytes according to the Checksum BBT32 following table XOR combination of all 7 bytes ADR XOR D1 XOR D2 XOR D3 XOR D4 XOR D5 XOR D6 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 A1 Button 8 Button 7 Button 6 Button 5 Button 4 Button 3 Button 2 Button 1 A2 Button 16 Button 15 Button 14 Button 13 Button 12 Button 11 Button 10 Button 9 A3 Button 24 Button 23 Button 22 Button 21 Button 20 Button 19 Button 18 Button 17 A4 Button 32 Button 31 Button 30 Button 29 Button 28 Button 27 Button 26 Button 25 A5 u S Display ON Input 3 Input 2 Input 1 Button 34 Button 33 A6 Message Message Message Message Message Message Message Message Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Button If a button is pressed its bit is set Message Number of current displayed message 10 bits Display ON The display is currently ON if this bit is set Input A set bit means the input is set Page 8 microSYST Systemelectroni
11. microSYST mitas pers2 1 Control Panel with 34 Buttons 34 LEDs LCD Display and serial Interface User s Manual microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas serse 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface Table of Contents 1 GENERAL 3 2 TECHNICAL INFORMATION 4 2 1 Serial Communication 5 2 1 1 LED Button Assignment 5 2 1 2 LCD Display 6 2 1 3 SD Card 6 2 1 4 CSV File 6 2 1 5 Starting Procedure 6 2 1 6 Control Frame 7 2 1 7 Response Frame 8 2 2 Examples 9 3 CONNECTOR PIN ASSIGNMENTS SETTINGS 10 3 1 Connectors 10 3 2 Switches 12 3 3 Status LEDs 13 4 MOUNTING OPTIONS 14 4 1 Panel Mounting 14 4 2 Housing 15 4 3 Pedestal 16 5 APPENDIX 17 5 1 Maintenance and Care 17 5 2 Warranty Liability 18 5 3 Versions Overview 19 Page 2 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas sers2 1 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 1 General The mitas BBT32 T control panel reduces previous wiring and installation efforts to a minimum 34 buttons with LED indication form the concept of the basic unit This unit is operated via a serial interface RS422 or RS485 Fault or inf
12. o 8 lines with 24 characters each 2 1 4 CSV File Messages can be created in an Excel table The file name must be Texte csv The first column contains the message number 0 to 1023 The second column contains the first line of the message 24 characters max The third column contains the second line of the message 24 characters max The ninth column contains the eighth line of the message 24 characters max Lines without message number in the first column are not evaluated So even headlines are possible The message number must be ascending Example Alert Line 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line 7 Line 8 0 Text1 Line1 Text1 Line2 Text1 Line3 Text1 Line4 Text1 Line5 Text1 Line6 Text1 Line7 Text1 Line8 i Text2 Line1 Text2 Line2 Text2 Line3 Text2 Line4 Text2 Line5 Text2 Line6 Text2 Line7 Text2 Line8 2 Text3 Line1 Text3 Line2 Text3 Line3 Text3 Line4 Text3 Line5 Text3 Line6 Text3 Line7 Text3 Line8 3 Text4 Line1 Text4 Line2 Text4 Line3 Text4 Line4 Text4 Line5 Text4 Line6 Text4 Line7 Text4 Line8 Error Line 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line 7 Line 8 4 Text5 Line1 Text5 Line2 Text5 Line3 Text5 Line4 Text5 Line5 Text5 Line6 Text5 Line7 Text5 Line8 5 Text6 Line1 Text6 Line2 Text6 Line3 Text6 Line4 Text6 Line5 Text6 Line6 Text6 Line7 Text
13. ormation messages can be displayed on the integrated LC dis play The messages are stored in a CSV file on a SD card Additionally 3 digital inputs and 3 digital outputs are available e g to con nect a key switch Page 3 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Germany Phone 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mitas BB732 7 Control Panel with 34 Buttons 34 LEDs LC Display and serial Interface 2 Technical Information General Specifications Interface Baud rate Addresses Keys LEDs Display Digital inputs Digital outputs Text memory Labelling Operating voltage Power consumption Mounting Protection Housing Housing dimensions Operating temperature Storage temperature RS485 RS422 2 4 to 115 2 kBaud adjustable 0 to 99 8x4 2 2 Taster 8 x 4 2 2 LEDs 4 LEDs for status display 2x POWER FAULT und DATA LCD two lines with 24 characters each white LED backlight quantity 3 24 VDC with additional common OV connection quantity 3 24 VDC max 200 mA per output 1024 messages on a SD card max 2 GB 1 message can extend up to 8 lines labelling strips 24 VDC 20 protected against polarity reversal approx 150 mA at 24 VDC operating voltage plus current for digital outputs load dependent panel mounting front panel IP65 without option housing powder coated sheet steel colour