SLP-P55 Smart Loader Package User's Manual
Contents
1. E Checking and changing the project properties To check the data that was input in the New Project window select Project gt Property from the menu bar Selections for PV input Auxiliary output and Communications can be changed here 12 Chapter 3 SETTING UP 3 3 Communications with the DCP551 552 Mark Il This section contains procedures for the following operations e Writing parameters and programs to the DCP e Importing parameters and programs from the DCP to projects e Displaying programs that are on the DCP e Deleting programs from the DCP L Handling Precautions e Before beginning communication with the DCP551 552 Mark Il change the setup data 4 communication port setting to 1 When set to 1 the communication port on the rear panel terminal base is disabled E Writing all parameters and programs to the DCP 1 Click the Ly icon on the toolbar gt gt The Write All SLP to DCP dialog box appears Write All SLP to DCP All parameters All programs The more segments the more time required For processing Backup options Back up DCP data before writing 2 Check both All parameters and All programs and click OK button gt gt The dialog box with progress bar will appear Writing to the DCP55 2 Writing Source SLP PID parameters Destination OCP PID parameters Remaining time 8 sec PTT IITLitt le 33 Cancel gt gt When the operation is complete
2. program setup operation methods maintenance and inspection troubleshooting and specifications DCP552 Marklil DIGITRONIK Digital Control Programmer User s Manual Manual No CP SP 1033E This manual is provided with the DCP552 double loop model It is required reading for those in charge of designing producing and maintaining control systems incorporating the DCP552 and for those using the DCP552 in other applications Its contents include mounting in a control panel wiring parameter setup program setup operation methods maintenance and inspection troubleshooting and specifications SLP P55 Smart Loader Package for DCP551 552 Markll Digital Control Programmer Manual No CP UM 5510E PDF file This manual A PDF version of this manual is supplied on the CD ROM of the SLP P55 system disk With the SLP P55 parameter setting and program setup for the DCP551 552 can be done on a PC running Windows 2000 XP Vista This manual tells how to operate the program Introduction to the SLP P55 Smart Loader Package for the DCP551 552 Mark II Digital Control Programmer Manual No CP UM 5509E This manual is supplied with the Smart Loader Package SLP P55 This manual tells how to install the SLP P55 on a Windows 2000 XP Vista PC ll Contents Conventions Used in This Manual Unpacking The Role of This Manual Chapter1 INTRODUCTION Chapter 2 STARTING QUITTING THE SLP M Starting up the SLP ccc ccc cece cec
3. Click the Delete From The Project in the pop up menu gt gt A dialog box asks whether to delete 4 Click OK button e Programs are deleted from the project by this operation but the program files are not deleted They remain in the folder of the open project To restore deleted program files to the project select the Project Import Existing Program command and then select the desired files 27 Chapter 3 SETTING UP E Switching segment RAMP types The RAMP type can be changed from the pop up program editing menu Display the pop up program editing menu for any cell of the desired segment and then select a type from among RAMP X RAMP T and RAMP E Note e The selected RAMP type for each segment is shown in the segment number cell in the program editing window Cell numbers with T E and with the number only are respectively RAMP T RAMP E and RAMP X No 03 PROGO3 Segment o osim oe SP 890 0 590 0 100 0 Segments 04 05 and 06 in the figure above are RAMP X RAMP T and RAMP H respectively E Turning off PV events Display the pop up program editing menu for the desired cell and select Event Off Pressing Ctrl T keys has the same effect E Inserting empty segments To insert a segment click any cell of the segment on the right of the desired loca tion to make it active in the program editing window Click the ar icon on the toolbar or Insert Segment in the
4. as well as multiple program patterns E File configuration of a project One project contains the following files KKK stands for the project name Project management file This file stores project information RK p55pri including DCP model information Each project has one file of this type Control data file for constants This file stores the settings of the Constant value k _parameter_const s55 control tab in the parameter setting window Each project has one file of this type Event configuration data file This file stores the settings of the Event xKKK_parameter_event s55 configuration data tab in the parameter setting window Each project has one file of this type PID parameter file This file stores the settings of the PID data tab _parameter_pid s55 in the parameter setting window Each project has one file of this type Setup data file This file stores the settings of the Setup data K _parameter_setup s55 tab in the parameter setting window Each project has one file of this type Variable parameter file This file stores the settings of the Variable k _parameter_variable s55 parameter tab in the parameter setting window Each project has one file of this type Program file This file stores the settings of the program xKKK_program x55 setting window A file of this type is created for stands for the double each program digit program number Chapter 3 SETTING UP o Handl
5. sessseeseressseereeeereeereeee 28 ie Turning ff PV GUI Ge se aoe oes Se re eee eee ee ee ee eee 28 E Inserting empty Segments cece eee ee eee reece eee cece eenees 28 E Copying and pasting segments ce ecceecen cence eeeeeeeeaees 29 Deleting SEGMENTS cece cece cece cere weer cece rece eres neces eeeeees 29 E Copying and pasting segment time data alone ee 29 E Copying and pasting patterns cece cece eee cece cence cence 30 E Saving programs and parameters from the DCP to PC files 30 E Importing programs and parameters from files saved by the SLP P55 UpDownloader for DCP551 552 sample loader software 31 3 6 Options and Confirmation cc cceecccecc cece cece esccescceseceseesces 32 E Specifying backup folders for DCP data eeeeeee scence 32 E Checking the DCP model number and status eee 33 ial Checking the SLP versio wi6o6 bose yew etn eeeeeo rs ob to55 bee essaweeecasas 33 Chapter 1 INTRODUCTION e Before starting the SLP P55 simply called the SLP from here on log in to Windows as a user with administrator privileges and quit all other applications If any other application is running during startup the SLP may malfunction Make sure that the setting for decimal symbol is a period If it has been set to some other character the loader cannot function correctly To change the dec ima
6. window Display Repeat Count Switches the display of the Repeat count C on off in the program editing window Display PV Start Switches the display of the PV start C Direction on off in the program editing window Display Cycle Number Switches the display of the Program cycle C on off in the program editing window Display Linked Parttern Switches the display of the Pattern link C Number on off in the program editing window Ie Pattern Preview Enlarges the pattern image and event graph of the program oy Refresh DCP Updates the information displayed for oe Information the DCP Project Import Parameter Imports parameter settings from other projects Create New Program a Adds a new program to a project op Import Existing Imports programs from other projects Program Imports files saved with the SLP P55 UpDownloader for DCP551 552 sample software Import Upload File Displays information about the open project such as model number and storage location Communications Copy Program Writes and reads programs to and from kS SLP lt gt DCP the DCP by drag and drop action fr Read Reads parameters or programs from F DCP to SLP the DCP Write Writes parameters or programs to the G w SLP to DCP DCP Read All Reads all parameters or all programs DCP to SLP or both from the DCP Write All Writes all parameters or all programs SLP to DCP or both to the DCP Delete All Deletes all prog
7. Be sure that the user receives this manual before the product is used Copying or duplicating this users manual in part or in whole is forbid den The information and specifications in this manual are subject to change without notice Considerable effort has been made to ensure that this manual is free from inaccuracies and omissions If you should find an error or omis sion please contact Yamatake Corporation In no event is Yamatake Corporation liable to anyone for any indirect special or consequential damages as a result of using this product 2008 Yamatake Corporation ALL RIGHTS RESERVED The DIGITRONIK is a trademark of Yamatake Corporation in Japan Conventions Used in This Manual The following conventions are used in this manual C Handling Precautions Handling Precautions indicate items that the user should pay attention to when handling the SLP P55 Note Notes indicate information that might benefit the user F This indicates the item or page that the user is requested to refer to 1 2 3 Numbers within parentheses indicate steps in a sequence or parts of an explanation OK button Indicates a selectable button on a personal computer screen File Indicates messages and menus displayed on the personal computer gt gt Indicates the result of an operation details displayed on the personal computer or other devices or the state of the device after operation Ctrl key Indicates keys on
8. E iA Process 03 rev 1 fal Parameters E Variable parameters a Variable parameters Item Display Setting z Event configuration d RCT SEAS TEPEE Key lock PA01 0 Keyloci abled Project VIEW a PID parameters ae Setup data Memory protect P4002 0 Disabled 2 Constant value contre Disp baono cottioo ae Q itono c ako di be Sole cto alae Gy Programs eye 2 No 01 PROGO1 sz G Local disk i i Editing area tag L No 01 PROGOL No 02 PROGO2 No 02 PROGOZ BY pcpss2 MARK2 600 0 1 10 E Pattern 5 1 Pattern image area 7 15 7 35 Evol Evo2 EVv03 Message bar Total segments 7 Program editing windows multiple Chapter 3 SETTING UP E Menu configuration list File E Create New Creates a new project Ctrl N in Project B Open Project a Opens a saved project _ Ctrl O Close Closes the top foreground window in the editing area Close al All Closes all windows in the editing area pen em the data from the top aaaea A window in the editing area by overwriting the older version Save All Saves all projects by overwriting the Shift Ctrl S older versions Save Project As Saves the open project with a new filename CSV Out Outputs all projects to files in CSV format p exit Quitsthe LPL the SLP Edit fat prms the data in the active cell of program editing window Event Off
9. Remaining time sec gt gt When the operation is complete the button in the box changes from Cancel to Close 3 Click Close to close the box Note e To stop reading before the process is finished click Cancel in the dialog box The cancel command might not work depending on when it is given 15 Chapter 3 SETTING UP E Reading only parameters or only specified programs from the DCP 1 To read only parameters display the parameter editing window in the fore ground of the editing area To read only specified programs display the program editing window in the foreground of the editing area To display the desired window in the foreground of the editing area refer to the following pages gt 3 4 Setting parameters W Basic operations page 20 3 5 Setting programs W Basic operations page 23 To copy a desired program into a project if there is not already a program with that number first create a new program file and assign the number to it 2 Click the Lb icon on the toolbar gt gt A dialog box appears to confirm reading 3 Click OK button gt gt A dialog box with progress bar appears 4 When the process is complete click Close button to close the box E Displaying programs that are on the DCP Programs read from the DCP can be displayed in the editing area just like pro grams that are being edited Pattern images and event graphs can also be shown here Displayed programs from t
10. gt The SLP starts and the menu window and handling precautions notice are displayed ox SLP P55 File Edit Yiew Project Communications Options Window Help CELOU T to Sid eerBimnael paRiao nae Handling Precautions 1 When creating a new project set the model number of the connected DCP A new project can be created by either of the following methods 1 Click Create new project on the start page 2 On the menu bar click File gt Create new project A mismatch of model numbers between the SLP and the connected DCP may make it impossible to write settings to the DCP 2 Before setting parameters set the PV range type Resetting a range type of PV may cause initialization of setting values partially 3 Before connecting to the DCP check its communications port setting Use the DCP console to display setup parameter C97 communications port and make sure that the setting is 1 If the setting is something other than 1 the DCP and loader cannot communicate C Do not show this dialog box again GPBefore connecting to the DCP check Its Communications port setting Use the DCP console to display setup parameter C97 communications port and make sure that the setting is 1 If the setting is something other than 1 the DCP and loader cannot communicate 2 Read the handling precautions and click OK button If you do not need to see this dialog box again put a check next to Do not show this dialog box again an
11. icon in the project window once and then right click it gt gt A pop up menu appears w Muy a gt B Local disk W No 01 PROGOI W No 02 PROGOZ BB DCP552 MARK2 L No 01 TEST1 Ww No 02 TEST2 synchronous 2 channel o Program auto load Unused Unused CH1 auto tuning CH1 auto tuning MV lowe 4 3 6 7 8 9 Get The Latest Program B Open Program X Delete Program From The DCP 4 Click the Delete Program From The DCP menu gt gt A dialog box appears for confirmation of deletion SLP P55 Confirm Y Do you want to delete Program No 03 TEST3 5 Click Yes button gt gt The program is deleted from the DCP and also from the project window Lg Programs gj Local disk W No 01 PROGOL W No 02 PROGOZ DCP552 MARK2 M No 01 TEST1 W No 02 TEST2 of L Handling Precautions 4 Synchronous 2 che 5 Program auto load 6 Unused 7 Unused 8 CH1 auto tuning 9 CH1 auto tuning M Variahla nar amatarc i Pus e Only programs on the DCP will be deleted Programs in the project will not be deleted e In step 3 if the Delete Program from the DCP menu is displayed in grey and cannot be selected close the program window in the editing area to enable the menu selection 18 Chapter 3 SETTING UP E Reading writing programs by drag and drop The window displays a list of SLP programs and a list of DCP programs Reading writing programs can be done by d
12. not possible to copy and paste data between different channels CH1 to CH2 or CH2 to CH1 but copy and paste is available within the same channel If the procedure used is not correct an error message appears E Saving programs and parameters from the DCP to PC files Note 30 Parameters and programs can be saved as PC files using the DCP console 1 Create a new DCP project 2 To read all parameters and programs from the DCP select Read All on the menu bar gt Reading all parameters and programs from the DCP page 15 3 To save a complete project click the i icon on the toolbar e This operation does not affect either the parameters or programs on the DCP e Parameters and programs saved to a file can be handled in the same way as para meters created by the SLP e To restore the DCP to its previous state according to the data saved on the PC open the project on the DCP and do the Delete All Programs operation Then choose Write All from the menu Without deleting all programs first the restored data may not be the same as the original because programs on the DCP before starting the Write All operation may not be deleted Chapter 3 SETTING UP E Importing programs and parameters from files saved by the SLP P55 UpDownloader for DCP551 552 sample loader software For the SLP to handle program and parameter files saved by the SLP P55 UpDownloader for DCP551 552 sample loader software it is necessary f
13. pop up program edit ing menu An empty segment will be inserted next to the active cell L Handling Precautions e f the maximum number of segments has already been reached in the program editing window a new segment is not allowed 28 Chapter 3 SETTING UP E Copying and pasting segments E Deleting segments To copy and paste segment data follow the steps below 1 Click any cell of the desired segment to make it active in the program editing window 2 Click the fe icon on the toolbar or Copy Segment in the pop up program editing menu 3 Click any cell of the target segment 4 Click the le icon on the toolbar or Paste Segment in the pop up program editing menu To paste a copied segment into a new segment insert an empty one before step 3 To delete a segment follow the procedure below 1 Click any cell of the desired segment to make it active in the program editing window 2 Click the s icon on the toolbar or Cut Segment in the pop up program editing menu E Copying and pasting segment time data alone In projects for the DCP552 it is possible to copy the time data set of one channel and paste it into the other channel The procedure is as follows 1 Display any program editing window in the foreground of the screen 2 Display the destination channel in front with the source channel behind it 3 Click Copy Segment Time Between Channels in the cell menu Lo Handlin
14. the button in the box changes from Cancel to Close 3 Click Close to close the box J Handling Precautions e To stop writing before the process is finished click Cancel button in the dialog box However data processed before canceling will be changed on the DCP For that reason make sure that both the parameter and pro gram settings are correct before starting the Write All operation e fthere is a program not associated with a project on the DCP it will not be possible to delete that program after the Write All operation To make the DCP contents match the project delete all programs on the DCP before starting the Write All operation Refer to CFH Deleting all programs in the DCP page 17 e Ona DCP552 Mark II with a ROM revision of R10 or earlier the setup data C64 event number division setting cannot be saved Configure this setting from the DCP552 keyboard 13 Chapter 3 SETTING UP e On a DCP552 Mark II with a ROM revision of R15 or earlier the setup data 45 auxiliary output 1 type and 48 auxiliary output 2 type set tings cannot be saved Configure these settings from the DCP552 key board The ROM revision can be checked by viewing setup data 3 ROM revision Note e To back up parameters and programs that are on the DCP before writing go to step 2 Check the Back up DCP data before writing box and then click OK button After confirmation that programs should be overwritten DCP par
15. the keyboard Ctrl a key Indicates the operation of pressing the a key on the keyboard while the Ctrl key is pressed Unpacking Check the following items when removing the SLP P55 from its package 1 Check the model No to make sure that you have received the product that you ordered 2 Check the SLP P55 for any apparent physical damage 3 Check the contents of the package against the Package List to make sure that all accessories are included in the package After unpacking handle the SLP P55 and its accessories taking care to prevent damage or loss of parts If an inconsistency is found or the package contents are not in order immediately contact your dealer System disk SLP P55J60 CD ROM A PDF version of gt the present manual No CP UM 5510E is also included 7 ia The Role of This Manual A total of four different manuals are available for the DCP551 552 Mark II Read them as necessary for your spe cific requirements If a manual you require is not available contact Yamatake Corporation or its dealer DCP551 Mark II DIGITRONIK Digital Control Programmer User s Manual Manual No CP SP 1032E This manual is provided with the DCP551 single loop model It is required reading for those in charge of designing producing and maintaining control systems incorporating the DCP551 and for those using the DCP551 in other applications Its contents include mounting in a control panel wiring parameter setup
16. 1 have only a CH1 tab in the lower left of the window One vertical row represents one segment Data cannot be input into grey colored cells RAMP X is the default first segment for a RAMP type setting If the title bar says Read only the window is a program window from the DCP While it is not possible to change settings segment data can be copied The number of event rows displayed depends on the event configuration data set tings and Setup data C64 event number division To display a simplified listing of event rows click the icon in the top row It is possible not to display linked pattern number rows individually from PID group numbers Even if they are not displayed their settings are retained When programs are written to the DCP the settings that are not visible go along with them In the image area in the menu window the program pattern in the foreground and the event graph are displayed In a DCP552 project when one channel tab in the program editing window is switched to the other the channel in the pattern image area is also switched auto matically As soon as the program settings are changed the pattern images and the event graph are updated automatically SLP P55 DCP552 202 File Edit view Project Communications AD bw oo Bl rora 3 i Process 03 rev 1 B Parameters Variable parameters Z Event configuration date 3 PID parameters Setup data 2 Constant value control d B E Programs 5 Lo
17. DCP 14 E Reading all parameters and programs from the DCP 15 E Reading only parameters or only specified programs from the DCP 15 E Displaying programs that are on the DCP eee ween ee eees 16 E Deleting all programs in the DCP cccce cece cece eee e ee eeceeneees 17 E Deleting specified programs from the DCP eeee eee e wees 18 E Reading writing programs by drag and drop seeeeeeeeeeee 19 3 4 Setting Parameters as ceed cceceieeydiiencesd dees eacaateens sdeeeweieene lanes 20 E Overview of the parameter editing WINdOW seeeeeeeeeeeee 20 ME Basic Operations 6 cece ccc reece reese reese reese csenesssssssssceeees 20 E Importing parameter settings from other projects 21 35 Prograin SeuinGS se lt as lt sectscscscasensesdeetenseceueaseasewesancedseeeees 22 E Overview of the program editing WINdOW seeeeeeeeeeeeeee 22 E Basic Operations cc cece ccc cece cece screens nec eeesnscssesesceees 23 E Creating a new program sss cs ccsee cn disceccntascdcesenctadaaeerecwrens 26 ili E Importing programs from other projects eeeee sees cece cece 26 M Changing tag NAMES cece cece eee cece cece r cece e eee eeeeeeeees 26 E Changing program HUMD Sooo oo oe 5 ee a oe ee eee oe eae OOS 27 M Deleting programS ssesesessssssossossoseeeseeseceeeeeeeeeeeeeeee 27 E Switching segment RAMP typeS s
18. LP P55 Confirm DY Do you want to delete all programs in the DCP 2 Click Yes button gt gt The dialog box with progress bar appears 3 When the operation is completed click Close to close the dialog box gt gt All programs are now deleted from the DCP and from the project window o Handling Precautions e This operation will delete programs from the DCP only not those in the project 17 Chapter 3 SETTING UP E Deleting specified programs from the DCP 1 Click the DCP icon in the project window once to select it EP oF YB a ies Process 03 rev 1 a Parameters Variable parameters 5 Event configuration di a PID parameters Setup data 3 Constant value contre B Programs 5 Local disk s No 01 PROGOI b No 02 PROGOZ DCP552 MARK2 A rege MAAS E Variable parameters Key lock Memory protect Display channel setting Synchronous 2 channe Program auto load CH1 auto tuning Variable parameters AEvent 2 Click the an icon on the toolbar gt gt Below the icon programs on the DCP are displayed in a tree view g YULI VIUS LUTILTL a Programs gj Local disk W No 01 PROGOI W No 02 PROGOZ DCP552 MARK2 No 01 TESTI L No 02 TEST2 L No 03 TEST3 sg Apiay UI niet DSL n Synchronous 2 chann Program auto load Unused Unused CH1 auto tuning variable parameters Event jwin jc 3 Click a program
19. No CP UM 5510E SLP P55 Smart Loader Package for DCP551 552 Mark II Digital Control Programmer User s Manual Thank you for purchasing the SLP P55 for the DCP551 552 Mark Il This manual contains information for ensuring correct use of the SLP P55 It also provides necessary information for maintenance and troubleshooting This manual should be read by those who design and maintain devices that use the SLP P55 Be sure to keep this manual nearby for handy reference Yamatake Corporation RESTRICTIONS ON USE This product has been designed developed and manufactured for general purpose application in machinery and equipment Accordingly when used in applications outlined below special care should be taken to implement a fail safe and or redundant design concept as well as a periodic maintenance program e Safety devices for plant worker protection e Start stop control devices for transportation and material handling machines e Aeronautical aerospace machines e Control devices for nuclear reactors Never use this product in applications where human safety may be put at risk IMPORTANT Do not apply a strong force while connecting a loader plug Doing so might damage the instrument L Handling Precautions Application of excessive force to the loader plug might cause communication failure If such failure happens reconnect the loader plug correctly NOTICE
20. P status Memory protect Operating status CH1 CH2 Number of remaining segments Number of remaining sub Functions 3 Click Close button gt gt The window closes Note READY READY Disabled 2000 Provided 4000 Close e It is not necessary to open a project in order to execute the Read The DCP Information command E Checking the SLP version 1 Select Help About SLP 55 gt gt The Version information window appears In the figure below the SLP version number is circled in red Version information SLP P55J60 Version 3 0 0 c 2008 Yamatake Corporation All Rights Reserved http iwi yamatake com azbil 33 Revision History date CP UM 5510E es e Nov 2008 Sub menu and description of View changed Precautions for communications added Precautions on ROM revision added to the Handling Precautions Precautions on ROM revision added to the Handling Precautions Menu name in step 1 changed Program editing window changed Setting of PID group number added Showing hiding event rows window changed Hiding displaying settings rows other than event rows window changed Program editing window changed azbil Yam at ake Corporation Specifications are subject to change without notice 08 Advanced Automation Company 1 12 2 Kawana Fujisawa Kanagawa 251 8522 Japan URL http www azbil com 1st Edition Issued in May 2008 W 2nd Ed
21. Project page 9 Note e This operation does not affect either the source program or project E Changing tag names Tag names can be changed on the toolbar Communications Options Windo Ke amp p Program Tag PROG0O1 A No 01 PROGO1 meters Segment Jration date 100 0 1 To change the tag name of the desired program open and display its program editing window in the foreground 2 Enter the new name in the Tag input box on the toolbar 26 Chapter 3 SETTING UP E Changing program numbers Program numbers are changed on the toolbar W No 01 KUG01 Segment 01 100 0 1 To change the number of the desired program open and display its program B Proso o X d Progi meters Jration date are editing window in the foreground 2 Select a number in the Program input box on the toolbar J Handling Precautions E Deleting programs Note e tis possible to change only to an unused number If the selected number is already in use an error message appears Programs are deleted in the project window Follow the steps below 1 Close the program editing window of the program you wish to delete if it is open 2 In the project window click and then right click the program name gt gt A pop up menu appears 3 Programs S E Local disk W No 01 PROGOL E DCP552 MAR E Edit X Delete From The Project A Comment 3
22. Turns off PV events in the program Ctrl T editing window Inserts a new segment to the left of the Ctrl Ins selected segment in the program editing window m Cut Segment Copies and deletes the selected segment Ctrl X data in the program editing window fs Copy Segment Copies the selected segment data in the Ctrl C program editing window Paste Segment Pastes segment data copied by the Cut Ctrl V D Segment or Copy Segment command onto the selected segment data Copy Pattern Copies all segment data in the program Shift Ctrl C editing window Paste Pattern Pastes segment data copied by the Copy Pattern command onto the program editing window View Display Segment Display PID Group Number Switches the display of the PID group number on off in the program editing window Display Output Limiter Switches the display of the Output limiter Group Number group on off in the program editing window Display G SOAK Type Switches the display of the G SOAK type on off in the program editing window Display G SORK Widthj Switches the display of the G SOAK width on off in the program editing window Insert New Segment Shift Ctrl V Display PV Shift Value Switches the display of the PV shift on off in the program editing window Chapter 3 SETTING UP View Display Segment Display Repeat Start Switches the display of the Repeat C segment on off in the program editing
23. ameter and program back up begins A window appears to show the progress of the back up and of the writing e Backup files will be stored in the folder specified under Options gt Preferences by the system environmental settings Refer to gt ll Specifying backup folders for DCP data page 32 e Refer to the approximate time required for reading writing below All parameters reading writing takes 6 s Programs reading writing 10 segments X one pattern about 6 s 20 segments X 10 patterns about 2 min 20 segments X 99 patterns about 19 min When automatic backup has been set up the parameters and programs on the device must be read before writing and there fore the actual time required is the total of reading time and writing time E Writing only parameters or only specified programs to the DCP 1 To write only parameters display the parameter editing window in the fore ground of the editing area To write only specified programs display the program editing window in the foreground of the editing area To display the desired window in the foreground of the editing area refer to the following pages gt 3 4 Setting parameters W Basic operations page 20 73 5 Setting programs W Basic operations page 23 2 Click the JL icon on the toolbar gt gt The Confirm writing of program dialog box appears When writing programs the program numbers in the destination can be changed in this dialog box Conf
24. cal disk No 01 PROGOL bA No 02 PROGOZ BB DCP552 MARK2 Options Window Help PROGOL 1 B 3 D PE um amp a amp k i a im uw Tag ox No 01 PROGO1 Segment TIME TODO d TOON a5ed yeas iy EVO1 Time event Off Time EVO2 PV upper limit EVO3 PV lower limit PID group number Output limiter group G SOAK type G SOA amp K width P shift Repeat segment Repeat count PV start Program cycle Pattern link gm gt CH1 ACH2 lO Range 0 00 to 500 00 hour min 0 0 to 3000 0 s Total segments 21 Chapter 3 SETTING UP E Basic operations Opening the program editing window Double click a project name in the project window Displaying the program editing window in the foreground of the menu window Use one of the following three methods e Double click a program name in the project window e Click the editing window of the program you wish to display in the editing area e Click the program name you wish to display among the tabs on the right edge of the editing area Editing a different channel To switch channels click the CH1 or CH2 tab on the bottom left of the program editing window inputting and changing settings Single click a cell to make it active Enter the desired setting from the keyboard Press Enter to finalize the input If the n
25. cuments My Computer q j J My Network Files of type SLP P55 Parameter file s55 v 2 Specify the other project folder and select the desired parameter files L Handling Precautions e Itis not possible to import any program from a project for a different DCP model If such a file is selected for import the following error message appears The model number of the DCP does not match the model num ber associated with the project Refer to gt 3 2 Creating and Saving a Project page 9 Note e To see the relationship between file names and parameters refer to CFH File configuration of a project page 4 e Importing parameter data does not affect either the source parameter data or the source project 21 Chapter 3 SETTING UP 3 5 Program Settings E Overview of the program editing window 22 W No 01 PROGO1 Segment 400 0 1 30 1 2 00 2 20 900 0 0 45 0 00 0 45 905 0 895 0 900 0 1 00 0 55 1 00 400 0 0 15 TIME 0 20 a5 EVO1 Time event Off Time EVO2 PV upper limit EVO3 PV lower limit PID group number Output limiter group G SOAK type G SOAK width PY shift Repeat segment Repeat count PV start Program cycle Pattern link zm CH1 One program editing window is assigned to each program Multiple windows can be open in the editing area at the same time Projects for the DCP55
26. d then click OK button gt gt The basic screen appears SLP P55 DER File Edit View Project Communications Options Window Help AM BOBS Bi rom iol jox mec Poa spac onal aed es Recently used projects g Process 03 rev 1 p55prj GA Process 03 p55prj 29 Process 02 p55prj EA Process 01 p55prj Create new project amp Create new project Open project B Open project Operating instructions Starting a project 4 project is a group of files used to create parameters and program patterns for the DCP550 4 project has a p55prj project file for saving project settings a s55 parameter file and a x55 program file Before connecting to the DCP check its communications port setting Use the DCP console to display setup parameter C97 communications port and make sure that the setting is 1 If the setting is something other than 1 the DCP and loader cannot communicate Note e Two or more instances of the SLP cannot be running at the same time o Handling Precautions e Projects can be created or modified on the start page Settings for com munications with the DCP can be changed from the menu bar e To have the handling precautions dialog box displayed again select Help Handling Precautions command on the menu bar Chapter 2 STARTING QUITTING THE SLP E Setting the communications port E Quitting the SLP 1 Select Option Preferences on the menu bar gt gt The Prefer
27. d to the disk overwriting the previous version After saving the project remains op en for other operations like editing E Saving only parameters specified programs 1 To save only the parameters display the parameter editing window in the fore ground of the editing area To save only specified programs display the program editing window in the foreground of the editing area To display the desired window in the foreground of the editing area refer to the following pages gt 3 4 Setting parameters W Basic operations page 20 gt 3 5 Setting programs W Basic operations page 23 2 Click the kH icon on the toolbar gt gt All parameter files are saved overwriting the previous versions After saving the project remains op en for operations like editing 11 Chapter 3 SETTING UP E Saving projects with another name To save a project with another name select File Save Project As from the menu bar E Saving project data to a CSV format file To save project data to a file in CSV format select File gt CSV Out from the menu bar All programs and parameters will be exported to a CSV file Note e A CSV format file is a text file delimited by commas and can be used in Microsoft Excel or other off the shelf spreadsheet applications e When opening a CSV file using Microsoft Excel the format in which numerical values time etc are displayed is converted to the standard Microsoft Excel for mat
28. e eee e eee n ne eeeeessennneeeeeeees 2 E Setting the communications port seeccee cece eeneeeeeeeees 3 E Quitting the SLP egct te ceen ccs tecce seen nsscsedoucususiiwessteswenetesest 3 Chapter 3 SETTING UP 3 1 Setup FUNCTIONS cece ccc ccc c ccc n ese c ene e nec eee nesses nesssssneseeees 4 E SLP IUMO eerren he 6 oo 566856 oe ATEENA REETA 4 E File configuration of a project essessesssossesssossossecssoeses 4 E SLP screen configuration s ssesssssesossossossssocsosssseceoes 5 M Menu configuration list s sessssssssesesscossscsosscossecesseceeees 5 3 2 Creating and Saving a Project cece cece cece e cece ener e eee eeeeeeees 9 E Creating a NEW DIOlGCts lt csenew cessor sacsedesssasuenianneeneeceeonsaes oon 9 M Opening existing projects cece cece cece cece eee eneeeeeeeeees 11 E Saving ProjectS 0 ccc cece wesc cece ewes sce c eens esseeeresssessseees 11 E Saving only parameters specified programs eeeeeee eee eeee 11 E Saving projects with another name sssssssesssssssesessosesees 12 E Saving project data to a CSV format file cece eee eee ee eee 12 E Checking and changing the project properties eee 12 3 3 Communications with the DCP551 552 Mark Il eee eee eee 13 E Writing all parameters and programs to the DCP 13 E Writing only parameters or only specified programs to the
29. e types of destination 1 The project folder used for writing 2 Any user specified folder The default is 1 1 Select Options Preferences gt gt The Preferences window appears Preferences Communications Write Options for writing to the DCP C Put backup files in a separate location from project folders Directory e 2 Switch to the Write tab 3 Check Put backup files in a separate location from project folders This step enables the selection of a user specified folder 4 Enter the desired folder name with the keyboard in the Directory input box or click the icon and select a folder from the folder selection window If the check mark is removed Use the project folder used for writing is select ed automatically Note e These settings are saved even after the SLP is turned off so they do not need to be reset after startup 32 Chapter 3 SETTING UP E Checking the DCP model number and status 1 Select Option Read The DCP Information gt gt The DCP information window appears Model information and DCP status displays will be blank 2 Click Read button gt gt Information retrieved from the DCP is displayed in the window DCP information Model information Model DCPS52 Mark2 dual loop control model Model number pcpss2 202 PY input Auxiliary output 2 channels 2 channels Communications DC
30. ead Only pL Feo ee ey eee ame 1m3 PA a D wm Ff nem een ee eee J e amp A Process 03 rev 1 B Parameters 3 Variable parameters Ng Bn Fm 0 02 PROGO Read onl OX a Event configuration d d y Max a PID parameters Setup data a Constant value contre 9 Programs B Local disk b No 01 PROGOI 3 _HEvo1 Time event Off od No 02 PROGOZ _ HEvO2 Pv upper limit S E DCP552 MARK2 H EvO3 pv lower limit No 01 TEST1 2 E 02 TEST2 PID group number L No 03 TEST3 B Variable parameters a Elle E E Output limiter group E G SOAK type G SOAK width PY shift lt im CHI o Handling Precautions e In step 3 if the selected program has already been read the process will be canceled and the previously read data will be displayed e Programs that are on the DCP cannot be saved as part of a project but they can be retained as long as the project is open e Programs read and displayed from the DCP cannot be written to the DCP To write a program from the DCP with a different program number first import the program to a project and then write it to the DCP gt H Reading only parameters or only specified programs from the DCP page 16 gt Writing only parameters or only specified programs to the DCP page 14 E Deleting all programs in the DCP 1 On the menu bar select Communications Delete All Programs gt gt A dialog box appears to confirm deletion of all programs S
31. ences screen appears USB loader cable is automatically selected 2 Click Communications tab 3 Click USB loader cable is automatically selected gt gt A communications port is automatically selected and displayed in the port box However automatic selection might be impossible for some types of communications port connector If so click the button on the right of the port display box to select another port 4 Click OK button Select File Exit on the menu bar or click the icon at the upper right of the window If the displayed project has been modified a dialog box will appear asking whether the user wants to save the project to a file Chapter 3 SETTING UP 3 17 Setup functions E SLP functions The SLP provides the following functions for configuring DCP operation Functions Sets the model No of the DCP Saves created program patterns and parameters to a file on the hard disk Reads saved files for editing Project management Writes created program patterns and parameters to the DCP Reads program patterns and parameters from the DCP Data communications Parameter editing Inputs and edits parameters Creates and edits programs Displays program patterns as images Displays events in graph form Program pattern editing Note e Project refers to data for one DCP Each project contains all project informa tion and parameters
32. erent channel even if that channel is put into the foreground C When the check is removed from a row on the menu bar the contents of the row disappear from the program editing window but the input values in the row are saved D In the project window or in the editing area this command updates information associated with the selected icon or window This command imports files saved with the SLP P55 UpDownloader for DCOP551 552 and modi fies them so that they can be used by the SLP x When a parameter window is in the foreground of the editing area this command reads a set of para meters from the DCP When a program window is in the foreground of the area the command reads the program from the DCP G When a parameter window is in the foreground of the editing area this command writes all parame ters to the DCP When a program window is in the foreground of the area the command writes that program alone to the DCP Chapter 3 SETTING UP 3 2 Creating and Saving a Project To set parameters and create programs create a project first Also when reading input parameters and programs from the DCP in order to save them to a PC create a project before reading E Creating a new project 1 Click Create new project on the start page SLP P55 File Edit View Project Communications Options Window Help FAS Ow B ot Bl Proven w aX te n Recently used projects A Process 03 rev 1 p55prj A P
33. ess 03 E Process 03 rev 1 E Machine II C PLANT C amp F PANTA ai 6 Select a folder in which to save the project and click the OK button gt gt The New Project window is again displayed Directly below the selected folder the SLP automatically creates a folder bearing the same name as the project in which to save the project files 7 If needed write notes concerning the project in the Comment space Notes can also be written and changed during program editing 8 Click OK button gt gt The New Project window closes and the project can be edited SLP P55 DCP552 202 elk File Edit View Project Communications Options Window Help CECOT CZ w Je xani fhinaa asaf snmnap E i Process 03 rev 2 r G E Parameters E Variable parameters SEE wn Display Setting Variable parameters POL 70 Keylock disabled e D Event configuration d E PID parameters Setup data Memory protect PA amp 02 0 Disabled Constant value contre Display channel setting PA03 0 2 items are displayed for the selecte a Programs Synchronous 2 channel operation PAO4 1 Synchronous ae Program auto load PAOS 0 OFF Unused PAO6 Unused PAO CH1 auto tuning PADS 0 AT not performed m 5437 3 Weed abed ye z o w o a s w a T o 3 a g 2 uw m gt 3 fal g a a CH1 Range Oto 3 Total segment
34. ew setting is not allowable it will revert to the previous value Clearing settings To clear settings with the keyboard press the Ctrl D keys To clear settings with the mouse select Clear from the pop up program editing menu for the desired cell gt H Displaying the pop up program editing menu page 25 o Handling Precautions e Pressing the Del key will not clear data in cells Setting of PID group number The setting range is 1 to 10 Settings 1 to 9 indicate PID group numbers 1 indi cates ON OFF control and 10 indicates automatic selection of PID group numbers A1 to A7 depending on the SP zone 23 Chapter 3 SETTING UP Showing hiding event rows When there are many event rows clicking the licon in the top row hides the other rows The icon then changes from to l l The icon indicates that there are hidden rows es or EB rrogram 4 ggi lag poem Eed de 4 es or gt Program 1 yy lag Bieta 4 FB No 01 PROGO1 W No 01 PROGO eters Segment ation date S Segment TIME TIME e control d EVO1 Time event Off Time PID group number EVO2 PY upper limit Output limiter group 0 G01 sane EVOS PV lower limit G SOAK type D 2 PID group number 0 2 G SOAK width Output limiter group D RoN G SOAK type 0 Repeat segment 0 G SOAK width Repeat count Clicking the l icon displays the hidden rows The icon then c
35. g Precautions e Time data is shown in the Time row of the program editing window e tis not possible to copy a segment with no time data e It is not possible to paste copied data onto other programs This opera tion can be done between channels for the same program e Time data alone can be copied SP values cannot However if the desti nation has no SP values the data will be set automatically as follows SP lower limit gt 0 SP lower limit SP upper limit lt 0 SP upper limit SP lower limit lt O lt SP upper limit O e f the time settings include RAMP T and RAMP E types the time data will not be synchronized with the actual time 29 Chapter 3 SETTING UP E Copying and pasting patterns Pattern settings can be copied from one program to another Follow the steps below 1 Display the program editing window of the copy source in the foreground 2 If the project is for DCP552 switch to the channel you desire to copy 3 Click Pattern Copy in the pop up program editing menu 4 Create a new program or display the editing window of an existing program in the foreground 5 If the project is for DCP552 switch to the channel from which the copy source was taken 6 Click Paste Pattern in the pop up program editing menu B Handling Precautions e When the Paste Pattern operation is done in an existing program all segments of the destination channel are overwritten elf the project is for DCP552 it is
36. hanges from to Hiding displaying settings rows other than event rows r ST e E Frogram 1 ej lag jrmwsaue g a Us FB No 01 PROGO1 B KrOgramy 1 gajagi nvo Display PID Group Number Display Output Limiter Group Number No 01 PROGO1 Segment Display G SOAK Type TIME Display G SOAK Width EVOL Time event On Time PID group number Display PY Shift Value Display Repeat Start Segment 24 Output limiter group Display Repeat Count G SOAK type Display PY Start Direction G SOAK width Display Cycle Number PV shift Repeat segment D Repeat count Display Linked Pattern Number PY start Program cycle 0 Pattern link 0 To hide any row from PID group number to Linked pattern number go to View Display Segment on the menu bar and remove the check marks for the rows you wish to hide To restore hidden rows check the desired row names Chapter 3 SETTING UP Displaying the pop up program editing menu Input cells in the program editing window have a pop up program editing menu To display the pop up program editing menu for a cell right click the cell am carta m A eS a A A SE L A E No 01 PROGO1 SEE eters Segment 01i 03 04 05 06 ation di 5P 100 0 99MM annn annn annn 10 i TIME 0 20 0 P Clear 1 s contrc SH EVO1 Time event On Time 0 15 m ENP EVO1 Time event Off Time 0 4 Insert New Segment
37. he DCP cannot be edited but copied segment data can be pasted onto them To display program data from the DCP in the editing area follow the steps below 1 Click the DCP icon in the project window once to select it Se ow M EA Process 03 rev 1 B Parameters 5 Variable parameters 5 Event configuration d w Boe E Variable parameters a PID parameters Setup data a Constant value contre B Programs B Local disk s No 01 PROGOI No 02 PROGOZ E BDCPSS2 MARK2 A Memory protect Display channel setting Synchronous 2 channe Program auto load CH1 auto tuning Variable parameters A Event 2 Click the An icon on the toolbar gt gt Below the icon programs on the DCP are displayed in a tree view E Sna yaiue LUIL a Programs B Local disk No 01 PROGOI Ww No 02 PROGOZ a BDCPSS2 MARK2Z No 01 TEST1 L No 02 TEST2 L No 03 TEST3 16 Lapay Ui nS PLN 1 Synchronous 2 chann Program auto load Unused Unused CH1 auto tuning Wariable parameters i Event Ops aon jt Chapter 3 SETTING UP SSS er 3 Double click the desired program icon gt gt A dialog box appears to confirm reading the program 4 Click OK button gt gt A dialog box with a progress bar appears When the operation is complete a window opens in the editing area and displays the program data on the DCP The title bar says R
38. ing Precautions e Do not use Windows file management software such as My Computer or Explorer to change file names Doing so will prevent the SLP from han dling the files properly e When copying projects to recording media like floppy disks save all files of a project as a group If any file is missing the SLP may not handle the project properly E SLP screen configuration Basic SLP screen e No projects are open Menu bar Start page SLP P55 File Edit View Project Communications Options Window Help Toolbar Lee Bw Bf Bl Poem ito lo Xm Gi Recently used projects E Process 03 rev 1 p55prj iA Process 03 p55prj GA Process 02 p55prj GA Process 01 p55prj Create new project amp Create new project Open project B Open project Operating instructions Starting a project 4 project is a group of files used to create parameters and program patterns for the DCPSSO 4 project has a p55prj project file for saving project settings a s55 parameter file and a x55 program file E Before connecting to the DCP check its communications port setting Use the DCP console to display setup parameter C97 communications port and make sure that the setting is 1 If the setting is something other than 1 the DCP and loader cannot communicate e The project is being edited Parameter editing window only one Editing area SLP P55 DCP552 202 File Edit View Project Communications Options Window Help
39. irm writing of program i The program will be written to the DCP552 Do you want to proceed The more segments the more time required for processing Programno 1 to Program no Backup options Back up DCP data before writing 14 Chapter 3 SETTING UP 3 Click OK button gt gt A dialog box with progress bar appears 4 When the process is complete click Close button to close the box Note e To back up parameters and programs that are on the DCP before writing go to step 2 Check the Back up DCP data before writing box and then click OK button After confirmation that programs should be overwritten DCP parameter and program back up begins A window appears to show the progress of the back up and of the writing e Backup files will be stored in the folder specified under Options gt Preferences by the system environmental settings Refer to gt H Specifying backup folders for DCP data page 32 E Reading all parameters and programs from the DCP 1 Click the 4b icon on the toolbar gt gt The Read All DCP to SLP dialog box appears Read All DCP to SLP All parameters All programs The more segments the more time required For processing 2 Check both All parameters and All programs and click OK button gt gt The dialog box with progress bar will appear Reading from the DCP55 Reading Source OCP PID parameters Destination 5LP PID parameters
40. irst to execute the Import Uploaded File command 1 Select Project Import uploaded file on the menu bar gt gt A file selection window appears Import uploaded file Destination folder for uploaded files CHAAA Factory PLANT Bi Machine IiProcess03 Backup e File name Name i Date 24012008_001 PID Parameters 1 25 2008 4 34 ee variable para 1 25 2008 4 34 ce ao D0 Event configu 1 25 2008 4 34 Setup data 1 25 2008 4 34 01 PROGO1 1 25 2008 4 34 03 PROGO3 1 25 2008 4 35 06 PROGOE 1 25 2008 4 35 4 08 PROGOS 1 25 2008 ar i 2 Check the desired file s and click Import button gt gt The file s will be imported into the open project o Handling Precautions e Importing is not possible unless the model numbers of the open project and the files to be uploaded match If they do not match create a new project matching the model number of the files you wish to upload and then import to the project 31 Chapter 3 SETTING UP 3 6 Options and confirmation This section treats the following e Specifying backup folders e Checking the status of the DCP e Checking the SLP version E Specifying backup folders for DCP data A backup for parameters and programs on the DCP can be made at the same time that parameters and programs are written from to the DCP from the SLP The backup files are stored in the folder specified in the Preferences window There are two possibl
41. ition Issued in Nov 2008 W
42. l symbol setting follow the procedure below e For Windows Vista Go to Control Panel Clock Language and Region Regional and Language Options Custmize this format button gt Decimal symbol Select and click OK button e For Windows XP Go to Control Panel Date Time Language and Regional Options Regional and Language Options tab gt Regional Options tab gt Custmize button Decimal symbol Select and click OK button e For Windows 2000 Go to Control Panel Regional Settings Number Decimal Symbol Select and click OK button On the DCP set Setup data C97 communications port to 1 For the setting procedures refer to gt CP SP 1032E for the CP551 Mark II gt CP SP 1033E for the DCP552 Mark II Without this setting the SLP and DCP cannot communicate Although you can set the SLP communications port at any time we recommend setting it when the SLP starts for the first time after installation CFH Setting the communications port page 3 For details on the operating system and the mouse you are using refer to the User s Manual provided with Windows Chapter 2 STARTING QUITTING THE SLP The following screens with descriptions are shown on the example of a personal computer OS XP E Starting up the SLP 1 Click Start button at the lower portion of the screen and select Programs SLP SLP P55 gt
43. le click any parameter name in the project window e Click the parameter editing window in the editing area e Click the Parameter tab on the right of the editing area Editing a different parameter To switch to a different parameter for editing follow the steps below e Click any parameter name in the project window e Double click the parameter name tab on the bottom of the parameter editing win dow Changing settings by selecting an option To change settings follow the steps below e To display the options single click and then right click the selected cell A menu appears with a selection of options e Click the selected cell once and enter the settings from the keyboard e Press the Enter key to finalize the data input e If the new setting is not allowable it will revert to the previous value Changing settings by entering numerical values Click the setting cell once and enter the desired setting Press the Enter key to finalize the data input If the new setting is not allowable it will revert to the previous value 20 Chapter 3 SETTING UP E Importing parameter settings from other projects 1 Select the Project Import parameters command gt gt The Open parameter window appears Open parameter Look in Process 03 rev 1 My Recent Process 03 rev 1_parameter_pid s55 Documents Process 03 rev 1_parameter_setup s55 B Process 03 rev 1_parameter_variable s55 Desktop se f My Do
44. on _ Hevo2 Pv upper limit 903 3 Cut Segment ae EVO3 PV lower limit gt 89 Copy Segment C G03 PID group number 0 T Paste Segment 2 Jutput fer gri 0 Copy Segment Time Between Channels G SQK type Copy Pattern G SOAK width Paste Pattern PY shift Repeat segment 0 RAMP X Repeat count RAMP T PY start 0 RAMP E Proanram cele n Clears the data of the active cell a Event Off Turns off event output of the active cell if only the cell has PV event The cell shows OFF Insert New Segment Inserts a new segment on the left of the selected segment Cut Segment Puts a copy of the current cell segment contents into memory and deletes the cell contents Copy Segment Puts a copy of the current cell segment contents into memory Paste Segment Pastes data copied by the Cut Segment or B Copy Segment command into the active cell Copy Segment Time Copies segment time data from the hidden channel and Between Channels _ pastes it onto the channel displayed in the foreground 1 Copy Pattern Copies all segment data 2 Paste Pattern Pastes all segment data copied by the Copy Pattern command 2 RAMP X Changes the type of the selected segment to RAMP X RAMP X segments show the segment number only RAMP T Changes the type of the selected segment to RAMP T RAMP T segments are displayed with a T next to the segment number Changes the type of the selected segment to RAMP E RAMP E segments are displayed
45. ragging and dropping the listed items It is possible to read write not only the same program number but also any number between the SLP and the DCP 1 Click the H icon on the toolbar gt gt The Copy program window appears The SLP list is on the left of the window and the DCP list is on the right Channel 1 and 2 programs are differentiated by EA and Ej icons e pew DYJE RUINS pua emae Uep ane ash rocess 03 rev 2 J Parameters 5 Variable parameters a Event configuration d 5 PID parameters 5 Setup data 3 Constant value contre PROGOZ 3KB 3 10 2008 PROGOZ J Programs 4 PROGOS 5 Local disk z PROGO4 L No 01 PROGOL a W No 02 PROGOZ 3 BB DCP552 MARK2 2 Drag the row of the desired program to read write and drop it on the target row gt gt A dialog box appears to confirm and execute reading writing o Handling Precautions e lf the target row for dropping displays a program name the program will be overwritten e t is not possible to copy from the DCP to the DCP or to copy within the SLP Note e Itis possible to arrange the lists at the top and bottom of the Copy program window 1 Click the icon on the toolbar gt gt The SLP list is at the top of the window and the DCP list is on the bottom sicvwy civysou VINES Vv evn racess O3 rev 2 ot J Parameters CS a x a Variable parameters LAR 3 Event configuration d E Ee a PID parameters Setup data 5 Constant value cont
46. rams from the DCP Programs No programs are deleted from the SLP Options Preferences Selects a communications port and Ctrl E options for writing to the DCP Read The DCP Reads and displays DCP model Ctrl l Information information and status Window Tile Vertical Arranges windows from left to right as vertical tiles in the editing area Tile Horizontal Arranges windows from top to bottom as horizontal tiles in the editing area Cascade Displays overlapping windows in the editing area Chapter 3 SETTING UP Window Horizontal Lists SLP and DCP programs separated Partitioning by a horizontal line Vertical Lists SLP and DCP programs separated ED TEE a vertical line Help Displays the user manual a PDF file Pe foe Handling Displays handling precautions identical Precautions S those displayed at SLP startup About SLP P55 Displays SLP version information Notes A When a command is given to close a window containing edited contents a dialog box appears asking whether to save the data to a file To save the window s contents to a file click Yes or Save All To close the window without saving the contents click No To cancel the close window command to keep the window open without saving click Cancel B In a DCP552 project only the channel in the foreground of the program editing window is available for copying or pasting It is not possible to paste onto a diff
47. re J Programs 3 Local disk W No 01 PROGOI W No 02 PROGOZ BB DCP552 MARK2 PROGOZ PROGOS PROGO4 2 To lay them out on the right and left again click the icon on the toolbar 19 Chapter 3 SETTING UP 3 4 Setting Parameters E Overview of the parameter editing window E Variable parameters O Display Setting Key lock PAOI 0 Keylock disabled Memory protect P402 0 Disabled Unused PAO3 __ Unused PAO4 Program auto load PoS 0 OFF Unused PAD Unused PAO CH1 auto tuning P408 0 AT not performed CH1 auto tuning MV lower limit P amp 09 CH1 auto tuning MV upperr limit PA10 CH1 SP bias PA11 0 0 CH1 P digital filter PA12 0 0 1 47 leari M bine mE aD Yariable parameters 4 Event configuration data 4 PID Parameters 4 Setup data 4 Constant value control 1 2 3 4 5 6 8 9 ele e oO pen M ae One parameter editing window is assigned to each project Enter the desired settings in the cells on the right hand side The message bar on the bottom of the menu window shows the setting range Data cannot be input into grey colored cells E Basic operations Opening a parameter editing window Double click any parameter name in the project window Displaying the parameter editing window in the foreground To display the parameter editing window in the foreground follow the steps below e Doub
48. rocess 03 p55prj ie Process 02 p55prj GA Process 01 p55prj Create new project re Create new project Open project 5i Open project Operating instructions gt gt The New project window appears New project Model selection BEE DCP551 DCPSS2 DCPSS2 Mark2 Mark2 Mark2 Carb Project uses the DCP551 Mark2 1 loop control model Configuration PY input Auxiliary output Communications 1 channel O Not provided Not provided 2 channels 1 channel Provided 2 channels Model number DCP551 202 Project Project name Process 03 rev 2 Directory C444 Factory PLANT B Machine I lad Revised by Nancy Mar 10 2008 Contents XXXXXXXXX XXXXXXX Comment Read the model number 2 Click the icon for the DCP model to which you wish to connect Select one of the three models e DCP551 Mark2 1 loop control model e DCP552 Mark2 Dual loop control model e DCP552 Mark2 Carbon potential model gt gt Settings that are not necessary for the selected DCP model cannot be set 3 In the Configuration section set the options for PV input Auxiliary output and Communications 4 After the above setup enter a project name in the Project Name input box 5 Click button Chapter 3 SETTING UP gt gt The folder selection dialog box appears New project Select a location to create a project oe 444 Factory E PLANT A PLANT B E Process 01 Process 02 mm Proc
49. s 0 at Note e In step 2 automatic type setup is possible If the communications port has already been set up under Options Preferences click Read the model number on the lower left of the New Project window The model number will be read from the DCP and then the correct DCP icon will be selected automatically o Handling Precautions e After creating a project the model and communications settings cannot be changed Changes in PV input and Auxiliary output are allowed e lt is not possible to import parameters or programs from a project for a different DCP model 10 Chapter 3 SETTING UP E Opening existing projects E Saving projects Up to five recently opened projects are displayed in the recently used projects win dow To open a project click the project name SLP P55 File Edit View Project Communications Options Window Help Sw a piron jo lo Xoo Program Recently used projects GN Process 03 rev 1 p55prj EA Process 03 p55prj GA Process 02 p55prj EA Process 01 p55prj Create new project To open a project that is not on the list click Open project Recently used projects A Process 03 rev 1 p55prj GA Process 03 p55prj EA Process 02 p55prj EA Process 01 p55prj Create new project Open project eB Open project Operating instructions 1 Click the fl icon on the toolbar gt gt The complete project is save
50. with an E next to the segment number 1 This menu is available for DCP552 projects only 2 Ina DCP552 project only the channel in the foreground is available for copying or pasting It is not possible to paste onto a different channel even if that channel is put into the foreground 25 Chapter 3 SETTING UP E Creating a new program To create a new program click the 4 icon on the toolbar Program numbers and tag names are assigned automatically based on the number of existing programs but they can be changed C H Changing program numbers page 27 gt Changing tag names below E Importing programs from other projects To import programs from other projects follow the steps below 1 Select Project Import Existing Program from the menu bar gt gt The Open Program window appears 2 Select the desired program and click Open button o Handling Precautions e f a program with the program number selected in step 2 is already used in the currently open project the imported program will overwrite the existing one When files to import are selected a dialog box is dis played asking whether to overwrite e Itis not possible to import any program from a project for a different DCP model If such a file is selected for import the following error message appears The model number of the DCP does not match the model num ber associated with the project Refer to gt 3 2 Creating and Saving a