Contents

1. Configuration Under Options Systemsettings the parameters for the processing could be changed as follows Configuration of the automatic print outs 4 x Alarm Settings 7 Alarm Period 0 00 00 4 hh mm ss Cancel Delta T E 5 0 Delta H 20 0 H Pre scaling 04 00 00 hh mm ss Fig 5 Configuration of the automatic alarm print out Alarm Period You may enter here the minimum alarm period desired before the automatic printing process starts The alarm period could be set secondwise and could be between 00 hours 00 minutes 00 seconds and 23 hours 59 minutes 59 seconds The pre set values are 4 hours 0 minutes and 0 second 01 03 2005 Page 6 11 User Guide for New functions SmartControl 1 4 doc Delta T A Delta T may be pre set for temperature channels If the value is exceeded an alarm signal will be sent even if the alarm period is not exceeded The pre set value is 5 0 C Delta H A Delta H may be pre set for temperature channels If the value is exceeded an alarm signal will be sent even if the alarm period is not exceeded The pre set value is 20 0 rH Pre scaling If an automatic alarm print out is set a diagram with the graph of the corresponding channel will be printed out You may configure in this field at what time before the first alarm occurs should the diagram be scaled 01 03 2005 Page 7 11 User Guide for New functions SmartControl 1 4 doc 5 MKT Stabilit
2. You may configure here the report period For each report Start Evaluation Start Evaluation End Evaluation Jou sare z 01 01 2003 30 06 2005 End Evaluation 01 07 200 31 07 2005 31 12 2005 01 08 31 12 2005 Add gt gt Change Delete Row Delete Table lt Back Continue gt Cancel Fig 8 Define Report Period for the MKT Stability Report You may define here the report period of your MKT report The list on the right side contains the defined period To define a report period enter it on the left side then use the key Insert gt gt to put it in the list You may enter as many period as you wish also non continuous Using the key Delete Line the marked line on the list will be deleted Using the 01 03 2005 Page 9 11 User Guide for New functions SmartControl 1 4 doc key Empty Table the entire list will be deleted Using the key Change the selected entry on the list will be overwritten with the actual data from the entry field MKT Stability Report x Configuration of MKT stability reports Test configure Report parameter Please verify the parameter necessary and change if needed Constant Delta H Constant R 83 144 kJ mole 0 0083144 kJimole K JV Use partial start and end intervals Method of average calculation Daily interval average of all measuring values Daily interval average from the lowest and the highest measuring value USP Weekly interval average o
3. of Report VBF Lager Summary VBF Lager 3 16 0 PT 100 C VBF Lager 3 16 05 YBF Lager 3 15 0 PT 100 C YBF Lager 3 15 03 Configured report period 01 01 2003 00 00 00 gt 30 06 2005 00 00 00 01 07 2003 00 00 00 gt 31 07 2005 00 00 00 01 08 2003 00 00 00 gt 31 12 2005 00 00 00 Constant Delta H 83 144 Constant R 0 0083144 Use partial start and end interval Daily interval average of all measuring values v lt Back Execute Cancel Fig 9 Summary and Processing of Reports In this dialog the configured report parameters of the MKT are summarized You may save here your report with its configured parameters under a definite name This enables you to load the saved report parameters for other reports The key Execute is not active if all necessary parameters are incomplete If the key is active you may start the processing of your report For the calculation and display of the MKT report the software starts a second window and transfers the configuration This allows you to process your MKT report and to run your online measurement simultaneously 01 03 2005 Page 11 11
4. User Guide for New functions SmartControl 1 4 doc User Manual SmartControl 1 4 This document describes the Modifications and Functions which are newly introduced in the Software SmartControl 1 4 Content 1 Multi TCP IP On and Offline 2 Candisplay 3 Offline Alarm 4 Automatic Alarm Prints 5 MKT Stability Report 1 Multi TCP IP On and Offline The existing functionality of the TCP IP connection is extended in a way that configured IP addresses in the system table could be used in the online as well as in the offline mode The communication layer was extended so that for each system table a communication component could be assigned if configured for this purpose In case a system table has no configuration for the possible connection the chosen connection type under Set Serial Interface will be used For the configuration of the connection type the respective functionality in the SmartControl must be activated x System Name Close Devy_Com at Help Available Devices Y 204 Opus 200 ID 204 jae pA 2081 Opus 200 ID 208 Delete 983 0 200i ID 983 A 989 Aa 200i ID ns Insert Di Di 4 Y GANDispiay Con Dionayio 4200 ME Phone Number _ Swe Net Work Settings Connect via TCP IP _OPUS Protocol Host IP Addres Port Number com_dev Fig 1 System table with configured TCP IP connection A configured TCP IP connection is used preferably If the system table contains a phone numb
5. alternative to the host address This should however be known by the system a respective entry in the file Y windir System32 Drivers Etc hosts must exist To test the host connection you may use the key beside the entry line All kinds of measuring data recording online or offline is based on system table If devices are available but not assigned to a system table they will not be used in the recording process This makes it possible to take out devices temporarily from the measuring process if necessary The channels and the measuring data of these devices still exist unless completely deleted These excluded channels will not be shown while selecting channels for display or for deleting memory A hint appears if you close the measurement setup with deactivated devices 01 03 2005 Page 2 11 User Guide for New functions SmartControl 1 4 doc 2 Candisplay For the newly developed device Candisplay the software is extended to identifying recording and writing of the E and to manual and automatic configuration A Candisplay contains no measuring channel e g SS Be ce Select OPUS CAN Display Can Display ID 42001 zH J General Can Display Configuration Active Displays Display Brightness Alarm Signal Alarm Frequency fi g 3000 a vv v Alarm Pause Missing Values until marked line 20 tin jo a I Audible Alarm Y 4 gt Display 1 Display 2 Display 3 Display 4 Channel to
6. ation to start 01 03 2005 Page 8 11 User Guide for New functions SmartControl 1 4 doc MKT Stability Report Configuration of MKT stability reports Channel Selection 23 H3 aan Channel Sensor Dim Description VBF Lager 3 16 0 PT 100 3G VBF Lager 3 16 05 a VBF Lager 3 15 0 PT 100 KS VBF Lager 3 15 03 O Giftraum 3 14 08 PT 100 2C Giftraum 3 14 08 mi BTM Lager 3 13 0 PT 100 E BTM Lager 3 13 02 O w rmeraum 2 PT 100 sO Warmeraum 2 Warmeraum 1 PT 100 G Warmeraum 1 C Bereitstellung PT 100 SG Bereitstellung Container 3 13 01 oO K hlbox 2 3 14 0 PT 100 SG K hlbox 2 3 14 03 O K hlbox 3 3 14 0 PT 100 a K hlbox 3 3 14 04 O K hlbox 1 3 14 0 PT 100 M K hlbox 1 3 14 02 C Bereitstellung A PT 100 kie Bereitstellung Ausgang F llgut C Warmeraum4 PT 100 C Warmeraum 4 OG 4 17 01 CO Gefriertruhe ohn PT 100 bg Gefriertruhe ohne Nummer 3 14 fe RICE Reraich 2 11 TEF Tarn frol hurm or MCF Rersich 211 NA Fa lt Back Continue gt Cancel Fig 7 Channel selection for the MKT Stability Report The list shown contains all available temperature channels of the loaded file Check mark the channels which should be considered in the MKT report and then click the key Continue By clicking the column title Channel Sensor etc you may change the sorting of the list MKT Stability Report Configuration of MKT stability reports Edit Report Period
7. be displayed Information can ID 35 Channel 1 Strom 1 Sensor Type Current Unit MA Label Digits after dec Pt 0 strom 1 Upper Alarm Value Lower Alarm Value Alarm Hysteresis 0 00 Display Alarm Modus 1 Mean Value Alarm Suppression 1 Min Value thax Value Fig 2 Configuration Candisplay Configuration Next to the general parameter register is the register Candisplay Configuration where specific parameters of the Candisplay may be set Active Display Channel The Candisplay can display between 0 to 4 measuring values Here you may chose the number of measuring values to be displayed The number of measuring values set to be displayed corresponds to the number of displays activated e g Display 1 until Display 4 Display Brightness You may set here the display brightness ranging from level 1 dark to level 4 bright Alarm Signal Candisplay alarms in 5 different alarm frequencies 1 5 You may chose here which alarm frequency is to be used 01 03 2005 Page 3 11 User Guide for New functions SmartControl 1 4 doc Alarm frequency You may set the alarm frequency between 500 and 3000 Hertz This choosen frequency will be shown in the field alarm signal Alarm pause After acknowledging the alarm you may set here the alarm pause using the key of the candisplay You may set values minutewise between 1 min and 20 minutes Measuring value gap until line Upon finishing your online
8. er meaning in the standard configuration Set Serial Interface a modem connection was chosen and a TCP IP address a connection for this system table via TCP IP will be established In case a system table does not contain a phone number for the modem connection and no IP address a phone number will be asked before connecting Configured connection type here has to be a modem 01 03 2005 Page 1 11 User Guide for New functions SmartControl 1 4 doc If the communication type under Set Serial interface is set to modem and all system tables are set to connect via TCP IP the modem connection will not open The communication will be established via TCP IP The following connection types are possible 1 serial several TCP IP connections 1 Modem several TCP IP connections Several TCP IP connections Several modem and TCP IP connections several modem connections offline only Several modem connections offline only Unnecessary connections will not be opened by the software To activate the TCP IP connection of the system table you must enter in the field host a valid object address The entry contains IP address and port number of the desired host and has the format XXX XXX XXX XXX YYYY whereby XXX is the IP address und YYYY is the port number of the host Both parts of the address are separated by a comma If the port number is omitted the port number 8000 will be used as standard A symbolic name could as well be used as
9. f all measuring values C Weekly interval average from the lowest and the highest measuring value USP Calculate MKT in the dimension of the selected channels Calculate MKT in Kelvin i Continue gt Cancel Fig 9 Additional Report Parameter In this dialog you may chose which MKT calculation is prefered and which report structure is desired Constant Delta H Constant Delta H is the activating energy in kJ mole The value is 83 144 kJ mole Constant R R is the universal gas constant in kJ mole K and has the value 0 0083144 Method of Mean Calculation The method of mean calculation shows ways of computing the necessary mean temperature value You may chose between daily or weekly mean value Daily or weekly mean values however are calculated from all measuring values of an intervall Daily or Weekly intervall mean value of all measuring values or from the lowest and the highest measuring values of an intervall Daily or Weekly intervall mean value from the lowest and the highest measuring values You may likewise chose here if the MKT should be calculated using the channel unit or the unit Kelvin 01 03 2005 Page 10 11 User Guide for New functions SmartControl 1 4 doc MKT Stability Report Configuration of MKT stability reports Save and Execute If desired you may save report on this site IF all parameters are correctly configured report will be process Name
10. measurement you may now configure at which time your measuring values will be indicated as a line based on the memory rate of the channels to be displayed The values to be set may range between 0 and 255 saving rate For example If the memory rate of a channel to be displayed is 1 min and the measuring process was stopped the last measured value will be indicated for 255 minutes Audible Alarm Via check box Audible Alarm you may switch the audible alarm of the candisplay ON or OFF If the audible alarm was switched OFF and an alarm exist the deactivated audible alarm will not send a signal However other alarm possibilities of the candisplay remain active blinking and will signal alarm Display 1 until Display 4 In the Channels to be displayed all active channels of a system table are listed If you chose a channel the parameters of the display with the corrresponding parameters of the channel will be configured In the Label you may enter and edit the first 16 characters of your channel description In Display by you may configure which value Mean Min Max or Sum of the channels should be displayed The selection is however limited depending on the channel configuration If the choosen channel measured only the mean value this selection will be the only one active Automatic Configuration If changes in the configuration of Opus devices result in changes of candisplay configuration these modifications will be aut
11. omatically be set and programmed in the candisplay The candisplay will likewise be reconfigured if the channels to be displayed are inactivated or if Opus is taken out of the respective system table During joining of files the candisplay configuration will be scanned of necessary changes The programming of candisplay could as well be left undone if the user desires it so 01 03 2005 Page 4 11 User Guide for New functions SmartControl 1 4 doc 3 Offline Alarm In the Version 1 4 the SmartControl is extended so that alarms could be tracked down by reading memory and that alarms could be listed down and displayed Alarm settings of the channels alarm suppression etc will be taken into consideration during tracking down of alarms i Events determined during memory reading Ioj x I Acknowledgement w ooo S No Type Time Channel Value Limit Min Limit Max Fig 3 List of alarms from memory reading The shown list in Fig 3 contains alarms which are determined by memory reading Other unacknowledge alarms will not be shown in this list Hint If you read the memory of the same period several times the determined alarms will be listed down several times as well Please remember this when reading memory Should data reading be done several times it is suggested to switch OFF alarm determination Start saving 13 03 2005 23 37 30 ons Cancel JV Use the time for the saving query JV Determine e
12. vents during memory reading Fig 4 Dialog time entries by maual memory reading In reading memory manually you may switch ON or OFF the function determination of events by using the check box determine event by reading memory You may likewise tick the check box ON or OFF in the dialog Options System Settings in the menu Events 01 03 2005 Page 5 11 User Guide for New functions SmartControl 1 4 doc 4 Automatic Alarm Printout The automatic alarm printout will be done on reaching default user defined values and includes a Single Channel Y t Diagram and the corresponding Single Event Printout of that event The processing of the printouts is independent of the alerting on the screen and on the central actor as well as the acknowledgments of the alarms If an automatic processing should be done can be switched on and off with the checkbox Automatic alarm print out in the dialog Options Systemsettings If the whole eventprocessing is deactivated then no alarm print outs will be generated The rules for the processing are defined as The automatic alar Printout should be done if a limiting value violation has occured and the measuring value is again within the limits and the duration of the violation was longer than Alarm Period 4h or the temperatur deviation was larger than Delta T 5 C since start of the violation or the humidity deviation was larger than Delta H 10 rel since start of the violation
13. y Report The SmartControl is extended to calculating indicating and printing out the Mean Kinetic Temperature The purpose of the MKT Mean Kinetic Temperature calculation is to assess the relevance of a short time temperature deviation for the product quality throughout the storage period To generate the MKT stability report activate under Evaluation the menu item MKT Stability Report The following dialog will guide you through report configuration MKT Stability Report x Configuration of MKT stability reports Information You may configure or modify here the parameters for the MKT stability report and then create the MKT stability report using the configured settings For each choosen channel an MKT stability report will be created within the configured period Report Selection Please select if you want to create a new report or load and use a saved report Create a new Report Load a saved Report and configure VBF Lager Delete Configure Cancel Fig 6 Information und start MKT Stability Report configuration Hint To activate this dialog a file must be loaded You may as well activate the dialog during online measurement You may exit the configuration of the MKT stability report anytime using the Cancel key Aside from general information about MKT report you have the possibility to load a saved report definition or generate a new definition Select the key Configur

Download Pdf Manuals

image

Related Search

Related Contents

H.264 Mega-Pixel Dome IP Camera ICA  T500 User Manual - HomeBrew Centre Grimsby  Smeg LSTA146S washer dryer  Alternative à la chirurgie esthétique La technologie médicale chez  Calendar Browser Administrator Manual  Catalogue Métal - Plafond et Mur  JA-154J mando a distancia bidireccional de cuatro botones  Icy Dock MB882SP-1S-2B storage enclosure  Blaupunkt IVMR-7001 Car Video System User Manual  Extratto  