Home

Elidy-WALL

image

Contents

1. 15 Elidy WALL 16 to 21 Rigging sers 16 Connections 20 PSX9 power unit 22 to 31 Description 22 Menu tree structure 24 Test Menu 25 Mapping 26 DMX addressing 28 Art Net 2 4 30 Utilily a 31 Technical specifications 32 to 41 Warranties u a 42 to 43 022772020777 72 uj Safety rules and precautions for use Introduction N B For your safety and that of others it is essential you read this manually carefully and follow the instructions closely N B This equipment is reserved for professional use It is not intended for domestic use This product can cause serious indeed fatal injuries by fire electrocution and falling from height Only experienced and qualified users are allowed to install and use products CHROMLECH s Elidy ranges Do not allow inexperienced persons to handle the products Before using for the first time ensure the product has not suffered any damage during transit If so DO NOT USE the product and contact your CHROMLECH dealer In all cases always inspect the mechanical and electrical parts of Elidy equipment before fitting to check they are not damaged In particular check the lifting points locking pins
2. PX103 PX104 PX105 PX106 Accessory Kit de c blage Elidy S cable Kit de Elidy S PX201 SparePart Ch ssis Frame PX202 Accessory Kit de mise en Rack PO Accessory pxa0 Accessory 205 Spare Pan Px206 Spare Pan PX207 PX301 PX302 PX305 PX401 Accessory Flight case pour Flight case for Elidy BIG amp Elidy BIG amp WALL WALL PX402 Accessory Flight case pour Flight case for Elidy S Elidy S PX403 Accessory Rack 14U pour Rack 14U for PSX9 PSX9 PX404 Accessory Flight case pour Flight case for PSX9 amp C ble PSX9 amp Cable PX405 Accessory Flight case pour Flight case for Bumper Bumper 33 Technical specifications Products Elidy PSX9_Power unit PX104 200 mm 787in 86 mm 3 39 in 112 5 mm 443 Input 100 230V 50 60Hz 3 5A 800W Output 48V 16 800W 34 d oe e naque Technical specifications Products Elidy BIG PX102 40 5 mm 950 5 mm 900 mm 10 mm R 0 25 in 35 Technical specifications Products Elidy WALL PX103 Els o el 3 N o E Ele Els wo Kasa Only on PSX9 48VDC 16A 36 or Technical specifications Accessories PX1 05 Accessory for PX101 PX102 PX103 Dummy Description Tile without electronics to increase the surface area artificially or to act as cover support
3. muku an dd RUE OR xxx Dum um gu x gen un xxi noa Fugen ug m a x d qup men mad mik xx er x Tx x Pr mm x xxx s x x mm QUE fu x efxx x xu x dab eet EEE et EEE mu x Tx wk x Uu x am SS SS SS Se Tee ET Km m ee m kk sa m m Hum m mx m x qup mim kx tm x T u wm men noe Gen o 9 0 O PG 0T o 686 6 0 0 G6 0 6 0 6 o 0 0 6 6 6 6 To finish off wire up the Elidy WALLs secure them frame by 1 m and start work on the next row raise your supporting 19 Cromlech _ lid Elidy WALL Connections The Elidy WALL must only be powered from a PSX9 power unit You must use only CHROMLECH cables M cable S cable Input connector The Elidy WALL is fitted with 3 XLR 4 input connectors Pinouts 3 3 pme 4 Cable characteristics Power supply 2 x 2mm Data Screened twisted pair 2 x 0 35mm 1 ELIDY WALL z 1 PSX9 Connect the cable bundles from the frame to the PSX9 power unit Different co
4. User Manual pl GE CHROMLECH 19 avenue Gabriel Faur 35235 THORIGNE FOUILLARD FRANCE Tel 33 2 23 20 77 67 Fax 33 2 23 20 75 71 E mail contact chromlech com Web www chromlech com issue Change ats 121120 121122 Lightened base 121123 Base for translation 121125 English version rone _ Hello Thank you for using our equipment and for your confidence in us We endeavour to provide you with high quality equipment which is reliable and easy to use We hope we meet your expectations If however you find defects or malfunctions we will be very happy to resolve any problems for you as quickly as possible This user manual relates to all products in the Elidy range For your safety please read this manual carefully before using the equipment for the first time 77772 ELIDY S t Willi DMX or Artnet control PSX9 808 I 3 S Cable S Cable ELIDY BIG eli mane ELIDY WALL M C ble M C ble M Chble M Cable Lighting Control Table of contents Safety guidelines and precautions for use 8 to 11 Elidy S uuu een 12 to 13 FRIQQUING 12 Connections 13 Elidy BIG ss 14 to 15 Rigging 14 Connections
5. an array fitted with a swivelling yoke The yoke can be removed It is fitted to the frame using the 4 screws provided A suitable safety sling must be used between the array and the rigging component Yoke mounting The yoke allows the Elidy BIG to be attached to any type of framework using standard hooks so that it can be panned and tilted easily N B yoke of the Elidy BIG has been designed to support a frame and its 9 ACTIVE TILES DO NOT HOOK OTHER FRAMES UNDERNEATH UNDER CIRCUMSTANCES MAY THE YOKE REPLACE A SPREADER BAR BUMPER 14 _ Elidy BIG Connections Fit the PSX9 power unit onto the frame using the support plate provided Connect the 3 outputs XLR 4 of the PSX 9 to the 3 inputs XLR 4 on the frame Connect the PSX 9 power unit to the mains 100 230V 50 60Hz 3 5 800W Connect the DMX or Ethernet cable You can if you want install the PSX9 remotely using an M Cable 15 Elidy WALL Rigging Elidy WALL Rigging The Elidy WALLs have been designed to be assembled VERTICALLY very quickly You assemble up to 11 Elidy WALLs one underneath the other 10 meters All the parts necessary for fitting are integrated in the frame of the Elidy WALL However it is essential to use the Elidy BUMPER spreader bar provided to start assembling each column 1 COLUMN 1 ELIDY BUMPER 1 Fitting the Elidy BUMPER Rigging must be carried o
6. and connectors If there is any doubt that one of these parts may be damaged or faulty DO NOT USE THE PARTS CONCERNED and contact your dealer The manufacturer cannot be held liable for damages caused by non compliance with safety installation and fitting instructions contained in this manual or by any modifications made to products in the Elidy range Non compliance with safety installation and fitting instructions or any modifi cations made to products in the Elidy range will nullify the warranty Products in CHROMLECH s Elidy range comply with EC standard Electrical safety N B RISK OF ELECTRIC SHOCKS ALWAYS DISCONNECT EQUIPMENT BEFORE HANDLING OR CARRYING OUT MAINTENANCE Check that your electrical installation complies with current standards Always connect the product to electrical ground The PSX 9 power unit must be connected directly to the mains 100 240 VAC 50 60 Hz DO NOT CONNECT TO AN ELECTRONIC OUTPUT dimmer solid state relay etc Do not connect any device other than the PSX9 power unit to the power supply repeater socket Ensure the repeater power supply is not overloaded MAX 16 A To ensure the PSX9 power unit operates satisfactorily be careful not to obstruct the ventilation grilles The Elidy S WALL and BIG products need a hybrid power cable designed by CHROMLECH to operate This cable is not supplied with the product and is available as an optional extra in a wide variety of lengths
7. down as when installing it Pack it away carefully after use 10 or Further information The protection rating for products in the Elidy range is IP 32 PRODUCTS IN THE ELIDY RANGE MUST NOT BE USED OUTSIDE WITHOUT PROTECTION FROM THE WEATHER Risk to the eyes Products in the Elidy range use high power LED Light Emit ting Diode light sources As such you are strongly advised not to look directly at the light source Prolonged exposure can cause ocular lesions Devices must not come into contact with a flammable surface In all cases comply with a distance of at least 200 mm between the devices and nearby flammable surfaces All information provided in this manual is liable to change without notice It is your responsibility to check for updates to this manual CHROMLECH reserves the right to modify and improve any aspect of the products in its range over time without being obliged to incorporate these modifications into products sold previously It is strictly prohibited to put products in the Elidy range a washing machine and even less in a microwave oven 11 Elidy S Rigging system The Elidy S is an array fitted with a swivelling double yoke The Elidy S yoke has 4 main functions 1 Attach the Elidy S by means of a standard proprietary hook Diameter of through hole for hook 13 mm see drawing The hook must be able to support the weight of the Elidy S namely 3 1 Kg A safety sling must be used
8. CHROMLECH declines any liability if other cables are used to operate products in the Elidy range Installation Products must be installed according to best practice by qualified and certi fied personnel Installation personnel should wear statutory safety equipment while putting up and taking down the system Ensure that the public and personnel are prevented from passing underneath the system while it is being rigged The rigging area must be cordoned off and inaccessible to the public Never leave the rigging system unattended during installation Do not allow anybody whether stage hands artistes or members of the public to climb jump or hang from products in the Elidy range Do not place any object however small on the equipment during rigging It may fall while the equipment is being suspended and cause personal injury NEVER attach any equipment other than CHROMLECH accessories to Elidy products CHROMLECH is not liable for rigging accessories that are not manufactured by CHROMLECH The safety cable not supplied must have a suitable SWL for the weight of the device you wish to secure The safety cable which must be attached correctly to the device and the support frame must be installed so that ifthe main support system fails the fall of the device will be limited as much as possible If a safety cable comes into play following a fall IT IS ESSENTIAL to replace it Take the same care when taking the system
9. DR ENTER Give a value between 1 and 287 using the keys and Confirm by pressing ENTER Then press EXIT twice to exit from the menu Tip Pressing simultaneously on and resets the value to 1 28 Comm lid Control Network menu The PSX9 power units can be controlled directly via an Artnet signal from a proprietary lighting console or media server To do this you have to configure the IP address of the power unit as well as the universe number 0 to 15 and the Subnet number 0 to 15 You can choose between 256 different DMX universes Universe 1 Universe 0 Subnet 0 Universe 16 Universe 15 Subnet 15 N B The ARTNET standard defines 2 different IP address types 2 X X X or 10 30 d minh sceme Utility menu Screen settings are found in this menu The settings are as follows Backlighting from 0 to 100 Contrast from 0 to 100 You can change the speed of the fan Cromlech _ lid Technical Specifications Make up of the Elidy product range KITS Elidy S Elidy WALL Elidy BIG 1 9 mme me pq T j 32 _ Technical specifications Ref amp Standards Part numbers and names of products accessories and spare parts Partnumber Famiy Nom Name English Product EldyS Px102 Product EidyBiG
10. PX106 Cable kit for Elidy S Description Minimum kit to supply 9 Elidy Ss with one PSX9 power unit PX202 Rack mounting kit Allows 2 PSX9 2Us to be racked PX203 Barndoors for Elidy S not available BIG Barndoor m Barndoors for Elidy BIG 37 vometh _ lider Technical specifications Accessories PX207 Bumper Ti B Description Column rigging system for 11 Elidy WALLS max fixed to the frame by 50 mm diameter collar PX301 Accessory for PX101 PX102 PX103 M Cable Not available PX302 een Juwm Accessory for PX101 PX102 PX103 S Cable Description Hybrid power cable 48V and data available in 2 6 and 12 m lengths PX305 for 103 Splitter 3 for Elidy S 38 _ Technical specifications Accessories Flight case for 6 Elidy WALLS or 3 Elidy BlGs PX402 Accessory for PX101 Flight case for 9 Elidy Ss 1 PSX9 Cables PX104 PX403 Accessory for Rack 14U for 12 PSX9s PX404 PX104 Flight case for 8 PSX9s and Cables PX405 Accessory for Flight case for 9 bumpers E elde Technical specifications Spare parts 100 mas p ds 205 room 1 u PX206 BIG Yoke emo ENT 4 WARRANTY Scope of the warranty Equipment is guaranteed against faulty materials and manufacturing faults for 1 one year from the date
11. between the array and the rigging component 2 Attach to another Elidy S in order to create a ladder of up to three Elidy Ss suspended one underneath the other Assembly is by means of two M10 nuts bolts inserted into the external drilled holes of the yoke see drawing A safety sling must be used between arrays and the rigging component 3 Install the Elidy S on the ground Through its double yoke the Elidy S may be placed on the ground and very simply swivelled into any position Ux En 4 Install the Elidy S on a standard proprietary mount 12 Elidy S Connections The Elidy S most only be powered from a PSX9 power unit You must use only CHROMLECH cables M cable S cable Input connector The Elidy S is fitted with one XLR 4 input connector Pinouts Power Gnd DMX 9 Power 48V 2 3 DMX Es Cable characteristics Power supply 2 x 2mm Data Screened twisted pair 2 x 0 35mm It is possible to connect 3 Elidy Ss onto each of the 3 PSX9 power outputs i e 9 Elidy Ss maximum per PSX9 To this end use the SPIDER BOX tapoff boxes provided for this purpose Never connect more than 3 Elidy Ss PSX9 output Do not exceed a total length of 25 m between the 5 9 and the Elidy S Do not chain more than 2 SPIDER BOXes Functional diagram t 5 8 s lt 5 x lt 13 Elidy BIG Rigging The Elidy BIG is
12. il of buttons and menu Rear panel Connectors from the mains supply of the PSX9 power unit Powercon True One connectors 1 Input 1 Output option to cascade PSX9 power units up to 16 A max Input protection fuses mains supply to the PSX9 power unit Serial number of the PSX9 power unit 30 240VAC sosar Input Link 164 max Output hes XLR 4 connectors on Neutrik socket 8 base to provide the Elidy tiles with O o 9 electrical and data power Data Fi F2 F3 i T Protection fuses for outputs 48V power supply and DMX for Elidy tiles The indicator LED lights up red if the fuse is out of action LED DATA copy of LED DATA on the front panel see table on previous page N B The number of the outputs is for information only you can reverse them without affecting the operation of the Elidy arrays 1 Output 3 ACTIVE TILES Max 23 Menu detail didy Pus rond Test Menu This function lets you directly control without DMX or ARTNET signal the brightness of your Elidy arrays This way you can easily check if your PSX9 power unit is correctly connected to your Elidy arrays Once you are in the menu press ENTER Use the keys to adjust the output level from 0 to 100 Press ENTER to leave the menu 25 ses Introduction 5 9 can operate up to 9 active tiles The
13. nfigurations are possible 1 PSX9 on the frame 2 5 9 installed remotely on a bridge above the screen 25m max 3 PSX9 installed remotely on the ground in a rack provided for this purpose 25m max 20 mane Functional diagrams M Cable Cable M Lighting Control 21 Yomlerh alid iage seine Power unit Detail of buttons and menu Front panel RJ45 network connectors On Neutrik socket base ARTNET control splitter Se nn type link for easy chain N chaining u Power supply configura e ON tion link to web browser e a _ eo N exit Enter Ome 7 N un DMX type XLR5 connectors On Neutrik socket base DMX input and output o Information Slow flashing LED Network 1 Network present x x x link on LED Network 2 Network present x x x link Data LED DATA 5 9 energised No DATA DATA OK Fault DMX or Artnet 4 Key functions Screen Setting function interface e 4 e Enter e Tor Depending on the context these keys also have an alternative function Shortcut to configuration view Shortcut to output status view amp Return to the Return to the Press simultane screen Min value ously lid Power unit Deta
14. of delivery subject to written notification that a fault has occurred being sent to CHROMLECH within 15 fifteen days If the equipment is repaired the repairs will be carried out by CHROMLECH or one of its subcontractors Only CHROMLECH has the authority to appoint the repairer If CHROMLECH carries out repairs and or replaces part or the equipment during the guarantee period the original guarantee period is not extended CHROMLECH has sole authority for deciding what action should be taken under the terms of this guarantee in particular whether the equipment should be repaired on the customer s site or whether the equipment should be returned by the customer to CHROMLECH so that it can be repaired Under the terms of the warranty the customer is liable for any risks and transport costs and may not claim for any losses due to the equipment being unavailable while under guarantee 42 rone _ Exclusions This warranty does not apply to visible faults The warranty is not valid in the following circumstances failure to comply with the recommendations for using and maintaining the equipment abnormal use of the equipment errors in operating the equipment failure to maintain the equipment repairs carried out by a third party without authorisation from CHROMLECH This warranty also excludes components with a life time in normal use that is less than the warranty period replacement of con
15. s are allocated the number 1 the LEDs of each tile will display no 1 and the menu will display Place the cursor in position 1 and press the ENTER key The tile in question flashes once and the menu displays Identify the desired allocation number e g 9 if the tile in question is located at the bottom right of an Elidy WALL Then increment the number between 1 and 9 and confirm using the ENTER key Place the cursor in position 2 and repeat the operation until you have allocated a number to all the tiles connected 27 elidu Introduction This menu lets you determine the DMX N address of your Power unit An active has 25 LEDs which are factory addressed as follows I dr 0000 V B This order cannot be changed Factory allocation of an active tile QO OO C On an Elidy WALL or an Elidy BIG there 9 active tiles i e 225 LEDs in total The address of each active tile will therefore be the following N DMX address of the PSX9 power unit DMX address of the PSX9 power unit N N 287 mxx ppeptperept Tiles Mapping menu 1 N 26 N 51 126 N 151 N 176 201 each Elidy S You can address 2 Elidy WALLs or BIGs 2x225 circuits in one DMX universe The first Power unit will be addressed as 1 and the next as 226 N B N Max 287 To change the allocation of the PSX9 power unit CONTROL ENTER AD
16. s off centre to create different orientation angles To do this you must only use one of the two bolts and space out the ends of each Elidy BUMPER Now you have created your Elidy BUMPER row you can assemble the Elidy WALLs underneath 17 Elidy WALL Rigging Elidy WALL consists of 9 Active panels and 1 Frame Its works with 1 PSX9 1 M cable or 3 S cables 1 Bumper for each Elidy WALL column 2 people are required to correctly assemble the Elidy WALLs on the Elidy BUMPERs Stand either side of the array to move and lock it You can grip the Elidy WALL anywhere All components can support the weight of the array Ensure your Elidy WALL is orientated correctly The female clevises of the load bearing components must be facing upwards and the connectors down wards N B the Elidy WALLs assembled vertically using the 2 load bearing com ponents provided The 3 transverse bars are only used for fixing the active tiles THE TRANSVERSE BARS ARE NOT A LOAD BEARING FRAME le To insert or unhook the detent pins you must press the red pushbutton fully down p to unlock the safety device lt 18 roll pd Start by assembling the central Elidy WALL Insert the female clevises of the Elidy WALL on the male clevises of the Elidy BUMPER up to the stops provided Lock the assembly using the 4 detent pins 2 on the Elidy BUMPER 2 on the Elidy WALL EM
17. se active tiles cannot be addressed directly on the array You must do this via the PSX9 power unit For the Elidy WALL and Elidy BIG addressing is factory configured as follows Tip To define the direction of the frame Female clevis facing upwards XLR connector facing downwards You will therefore only need to access this menu if you need to replace a defective active tile On the other hand if you have received Elidy Ss these are all addressed as 1 by default You will therefore need to differentiate them to make them operate correctly To define the direction of the frame XLR connector facing upwards Access the SETUP MAPPING menu press ENTER Doing this starts the procedure for detecting active tiles connected to the 5 9 DO DISCONNECT THE POWER SUPPLY AT THIS POINT DO NOT DISCONNECT THE ACTIVE TILES This operation may take a few seconds Once all the active tiles have been detected the corresponding number 1 to 9 is displayed directly on the tiles At the same time a new window opens on the power unit 26 Changing the allocation of Elidy tiles from the PSX9 power unit The mapping menu appears as follows The top row is fixed this a representation of the 9 tiles which The second row is where the cursor moves it displays the The cursor is moved along the row by means ofthe and keys The current allocation number is displayed on each tile If for example all the tile
18. sumables wear parts in particular lamps filters gobos flight case faults and their consequences resulting from external causes 43 CHROMLECH 19 avenue Gabriel Faur 35235 THORIGNE FOUILLARD FRANCE Tel 33 2 23 20 77 67 Fax 33 2 23 20 75 71 E mail contact chromlech com Web www chromlech com db MATE SCENE
19. ut by qualified personnel for more information refer to chapter Safety rules and precautions for use Ensure that the support on which the Elidy WALL is to be rigged can support the load is in a good state of repair stable and made safe In all cases YOU ARE FULLY LIABLE FOR THE SUPPORTING FRAME ON WHICH THE ELIDY WALLS ARE MOUNTED The Elidy BUMPERs must be fixed to the supporting frame using 2 double collars diameter 50 mm not supplied These double collars must have an SWL suited to the height and weight of your column 1 ELIDY WALL 30 Kgs including power supply and cabling 11 ELIDY WALL 330 Kgs We recommend you begin assembling your wall with the central Elidy BUMPER This will ensure your rig is centred correctly Then place the Elidy BUMPERs either side of your reference point to form your first row 16 Elidy WALL Rigging The ideal collar location on the Elidy BUMPER is as follows However it may not be possible to produce this configuration In this case you can move the collars on the Elidy BUMPER However you must ensure the collars are installed within the male clevises Check the Elidy BUMPER is orientated correctly The clevis stops and quick release pins must be pointing downwards To fit the Elidy BUMPERs to each other you must use the bolts provided For assembly in a row lock the 2 bolts as indicated below You can also place the Elidy BUMPER

Download Pdf Manuals

image

Related Search

Elidy WALL elida wall tile elida wallack elity w polsce elida wall tile 869355 elida wallack photography elity w margonem

Related Contents

Massive Table lamp 43208/30/10  Peg Perego Fiat 500 User's Manual  Black & Decker D905 Use & Care Manual  グランドライト 80 1 各部名称 2 取付方法    Installation Instructions and User Guide 15mm  Powermate PC0525302.02 Parts list  Philips Presenter SNP3000U  MS-246.4 U MS-246.4 UE MS-246.4 C MS-246.4 CE MS  

Copyright © All rights reserved.
Failed to retrieve file