Home
SNMP web card user manual-20130530
Contents
1. null 192 168 103 165 SNMPPO1 00000000000001 UPS information Line mode Disconnected Disconnected Input information 238 3V 50 0Hz Output information 229 8V 50 0Hz Battery information 41 0V 100 null 192 168 103 163 SNMPPO1 00000000000003 mull 192 168 103 162 SNMPPOO 00000000000004 null 192 168 103 161 SNMPPO03 00000000000005 eu Disconnected Disconnected Disconnected Chart 1 6 P Power Walker 2 SNMP web card GUI SNMP web card GUI includes function menu login section and main screen Refer to Chart 2 1 SNMP Web Server Windows Internet Explorer ERES Go http 192 168 107 109 sl Bild CSS as File Edit view Favorites Tools Help r Favorites snmp Web Server Ze lt EN 2 E v Pager Safety Tools e 3 o amm UPS information 3 x UPS mode UPS temp 39 6 C ECO Mode false Bypass when UPS is of Na Bypass not allowed false Fault type ON MM MN NN Input information Input voltage 213 7 V Input frequency 50 0 Hz Output information Output voltage 229 8 V Output frequency Load level Battery information Battery voltage Battery capacity 100 De Remaining backup time 999Min EMD information EMD temp 26 1 C Humidity 63 7 javascript e Kai Internet Chart 2 1 A SNMP web card GUI version B Function Menu It offers complete tool set for navigation an
2. SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems B Table of Contents RS 3 I T MOG CH OPE EE 3 IN ME cili Om 3 NAMES ee ERREUR 3 eee Ee EE C onnee e EE 4 INE roS EE 5 Ee ere 5 GN eer E E EE 7 SEE re UII 8 S O DENTIST mc 8 CNN D e E E E E 8 cM ASIC IN ei gank de EEN 8 ESPRIT HUI RE D Em 9 3 2 1 Parameters EENEG RTT 9 ME GG 11 Idla dedistis CONTO E 11 E MESURES E UE EUN T TT TO TL TT TELE 12 Dekla WEDUSE 12 SE Mii T 13 a I 14 3 4 4 Wake on LAN BEE 15 Ikas AON D 16 TOs EVENT Leg e EE 16 cr eui eee 18 3 4 8 System e lu 19 3 4 9 SNMP configuration nennen emen enne enn 19 De BIOS 20 3 5 1 EVeHL Le Le BEE 20 oS AP ue We EE 2I Oe po ERR TI 22 38 P PowerWalker 1 Overview 1 1 Introduction This SNMP Web card can provide web server to monitor and manage multiple UPSs in a networked environment including LAN and INTERNET It can detect temperature and humidity for the environment via connecting to EMD Environmental Monitoring Device Integrated with Shutdown Wizard it can not only prevent data loss from power outage and safely shutdown systems but also sto
3. E Chart 1 4 C User can modify IP setting online upgrade password management and static trap address setting in SNMP Web Manager interface It is necessary to enter password for any medications The default password is 12345678 Please check SNMP Web Manager User Manual for detailed configuration 1 6 Monitoring There are two ways to monitor a Double click the selected device from the device list refer to Chart 1 4 to open web page as Chart 1 5 O ML SNMP Web Server Windows Internet Explorer Sees Go iB bttp 192 168 107 109 sl 3 4 x Live Search e File Edit View Favorites Tools Help ie Favorites snmp Web Server n gt gt E C3 de Pager Safety Tools 3 i a Status Administrato UPS information ____Attoreboot tue Cometermode false Drees na dene false Faulttype MEN EBEN Input information Input voltage 213 7 V Input frequency B 0Hz Output information Output voltage 229 8 V Output frequency Load level Battery information Battery voltage Battery capacity 100 96 Remaining backup time 999 Min EMD information EMD temp 26 1 C O Humidty 63 7 javascript o Q internet Chart 1 5 b Installed ViewPower Pro software to monitor SNMP web card refer to Chart 1 6 Please check ViewPower Pro User Manual for detailed monitoring ak d Ge I a Graphic view j List view 192 168 103 166 SNMPPO1
4. name Receive FF Apply Delete SS j j Control Password E eceive R tro After apply you can click Test button to send a 4 Apply Delete System configuration noe test message To internet ESCHER Chart 3 8 3 4 4 Wake on LAN It s to remotely wake on specific PCs in LAN when these PCs are supported to Wake on LAN WOL via a magic packet Select System Configuration gt gt Wake on LAN Refer to Chart 3 9 7 SNMP Web Server Windows Internet Explorer IE 6 eA Je EEGEN sl Rs ox t Live Search ei Fie Edit view Favorites Tools Help we Favorites snmp Web Server th E Pager Safety Tools e 3 Wake on LAN MAC address 1 C8 0A A9 5B 31 BS MAC address 2 00 00 00 00 00 00 MAC address 4 00 00 00 00 00 00 MAC address format 01 1F C6 C7 E0 08 o Internet ax 100 7 Chart 3 9 After MAC addresses of remote PCs are entered into address column it will allow to remote control the PCs However it s also required to have Q Power Walker hardware support for remote PCs to implement this function 3 4 5 Shutdown It is to remotely shut down specific PCs with Shutdown Wizard This function is only available to integrate with Shutdown Wizard Please also check user manual of Shutdown Wizard for the details Select System Configuration gt gt Shutdown Refer to Chart 3 10
5. 16 MAL a 3 6 Help 3 6 1 Serial Port Debug It s to test communication condition between SNMP card and device Select Help gt gt Serial Port Debug Refer to Chart 3 17 7 SNMP Web Server Windows Internet Explorer IE Go btn 192 168 107 109 SR x B Live Search IF File Edit View Favorites Tools Help EN Favorites Sau web UM t E E Page gt Safety Tools e 3 AIAAG kb AA Information Send OCS contend acs Grieg 212 0 49 9 229 6 49 9 000 2 004 376 4 377 2 041 0 040 0 100000000001 window Control Real tro aan Pu System configuration j gt Lg internet p Om s Chart 3 17
6. alarm mail by SMTP server To use this function the e mail service must be correctly configured All values in this function page are default empty This action can t be executed without the SMTP information e mail account and password Besides the sender account should be allowed for SMTP POP3 forwarding Select System Configuration gt gt E mail Refer to Chart 3 7 AM ML e SNMP Web Server Windows Internet Explorer E htt 192 168 107 109 File Edit View Favorites Tools Help y Favorites E SNMP Web Server Ire ERAI LU PA A ende er Is M Eq CNMP V Jah Saruer n J SINKIP Wep Server 20 SMTP test com Receive 1 Apply Ja Receive 2 Delete Send from name gtest com Receive 3 ply Receive 4 LApply User name name l Forgot Need Auth Pateren Apply Password After apply you can click Test button to send a test message Note Recipient s Email Address for Daily Report Account 1 Account 2 Send Email for Daily Report hh mm at 00 00 Send Email when Event Log overflows 100 records Send Email when Data Log overflows 500 records C E amp Internet Chart 3 7 1 Enter SMTP server SMTP port sender s E mail address user name and password Click checkbox of Need Auth for password verify 2 Enter correct e mail accounts in R
7. NMP configuration Parameters setting Real time control mp EMD alarming humidity upper limit 96 Apply Event log Data log Data record interval DU Sec Apply o internet Chart 3 11 Shutdown the PC while battery mode When selected integrated with Shutdown Wizard local PC will shut down while UPS works on battery mode e Time needed for shutting down the PC Enter the delay time to shut down the operating system e The PC should 1 Shutdown When clicking the checkbox the selected system will shut down The default setting is clicked 2 Sleep mode When clicking the checkbox selected system will Suspend the system instead of a normal shutdown But this function is only supported by Windows 2000 or higher on supported hardware Also power off the UPS after shutting down the PC When click the checkbox monitored UPS will turn off after local system shuts down The UPS shutdown time will be later than system complete shutdown time Users can choose to shut down the system without shutting down the UPS e Shutdown UPS output after xx sec It will cut off UPS output after monitored UPS works on battery mode for xx sec e Shutdown the PC while low battery When clicking this checkbox local PC will shut down when monitored UPS battery is running low Wake on LAN while AC recovery When clicking this checkbox the local PC will be wake on LAN while AC recovery e Send E mail while any UPS event
8. SNMP Web Server Windows Internet Explorer EIE Go l http 192 168 107 109 F R l s a BP Live Searc p File Edit View Favorites Tools Help r Favorites sP Web Server gt A Sl e Page Safety Toos 3 IP address 1 192 168 107 11 IP address 2 0 0 0 0 IP address 3 0 0 0 0 IP address 4 0 0 0 0 IP address format 192 168 102 101 A internet fg 100 Chart 3 10 3 4 6 Event action This function is only available to integrate with Shutdown Wizard Please also check user manual of Shutdown Wizard for the details Select System Configuration gt gt Event action Refer to Chart 3 11 2 SNMP Web Server Windows Internet Explorer EIE e BEE O J gt http 192 168 107 122 i Hir File Edit view Favorites Tools Help r Favorites amp SNMP Web Server qum IMP Web Server 20 RL C Shutdown the PC while battery mode Apply Time needed for shutting down the PC 420 1j Sec The PC should 9 Shutdown Go to sleep Also power off the UPS after shutting down the PC Shutdown UPS output after 1800 Sec CI Shutdown the PC while low battery APPly C Wake on LAN while AC recovery Apply erri CI Send E mail while any UPS s event occurs Apply Event action C Send SMS while any UPS s event occurs Apply Scheduled E System time EMD alarming temperature upper limit S
9. attery deep discharge protection If enabled the monitored UPS shuts down in accordance with the condition of battery and load on battery mode to protect battery Vice versa gt Site fault detection If enabled the monitored UPS will beep when the input neutral and hot wires are reversed Vice versa gt Pi Programmable outlet control battery mode If enabled when UPS is running at battery mode it will cut off P1 outlets after backup setting time arrives If disabled UPS will provide continuous power to P1 outlets until the battery is running out gt Outlet setting Users can set limited backup time for P1 outlets when UPS is on battery mode gt Battery numbers setting Set battery numbers in parallel Voltage and frequency range for bypass mode Set acceptable voltage and frequency range in bypass mode Maximum and minimum voltage When UPS is on bypass mode and input voltage is out of setting range UPS will enter battery mode Maximum and minimum frequency When UPS is on bypass mode and input frequency is out of setting range UPS will enter battery mode Voltage range for ECO mode Set acceptable voltage range for ECO mode 3 3 Control 3 3 1 Real time control Select Control gt gt Real time control Refer to Chart 3 5 MALLEM Tn SNMP Web Server Windows Internet Explorer SEE Go e http 192 168 107 109 JAIE M Live Sea H File Edit View Favorites Tools Help 3 Favo
10. b Server Windows Internet Explorer ERES T j DS x 1 al Go http 192 168 107 109 4 BA 9 gt lt LT Search e File Edit View Favorites Tools Help F Favorites snmp Web Server fp gt E Cl de o Page Safety Tos 3 Basic information UPS type Input phase Output phase Iput eg UPS serial number 12345678901234 UPS FW version 00443 00 SNMP FW version 9 00 720 3 OH Real time control A iei ise ri Battery information emm Batey group number 3 UPS rated information Rated VA 1000 0 VA Rated output voltage 230 0 V Rated output frequency 50 0 Hz Rated battery voltage Internet 4g Im e E ai Chart 3 2 3 2 UPS setting 3 2 1 Parameters setting Some UPS functions can be set and changed via software Parameter setting includes backup time setting for programmable outlet P1 battery number setting voltage and frequency range setting for bypass mode and voltage range setting for ECO mode Select UPS setting gt gt Parameters setting Refer to Chart 3 4 Powe Walker 2 SNMP Web Server Windows Internet Explorer E Qc eesnsamamam FBl e roe e Jer File Edit view Favorites Tools Help F Favorites SNMP Web Server fp SY geh Page gt Safety Tools e 3 SNMP Web Server 20 MEME Advanced ECO mode nc ANO AES bes ut Adr e iL cS Renn fite e v NA Ce Enable X Disable Basic information Alar
11. d setting the GUI C Main Screen It will display information and or control alternatives according to function menu selected D Login section It shows user type for current login user The default password for administrator is 12345678 O ML 3 Function Menu 3 1 Information 3 1 1 Status Select Information Status Refer to Chart 3 1 It s shown real time monitored UPS data including input output UPS battery information and environmental information in table format SNMP Web Server Windows Internet Explorer BRE Go le http 192 168 107 109 ger gt LT Search Jiel Fie Edit View Favorites Tools Help Si Favorites sume Web Server i fp OE Cl d Page Safety Toos 3 UPS information OO Amorebtie O Comener mode fase Bypass not alowed ber Fame V Input information Input voltage 213 7 V Input frequency 50 0 Hz Output information Output voltage 229 8 V Output frequency Load level Battery information Battery voltage Battery capacity 100 Remaining backuptime 999Min 0 anal ce LP CD Serial Port Debug SO LAR EMD information EMD temp 26 1 C Humidity 637 o internet 4g Qio v Chart 3 1 3 1 2 Basic information Select Information Basic information It includes UPS basic information battery information and UPS rated information Refer to Chart 3 2 QO PowerWalker SNMP We
12. eceive list Then click Apply to add into receivers list Click Delete button to delete e mail account 3 Click Apply to save the changes The Test button can be used to send a test e mail to all receivers to confirm correct operation When the test e mails are successfully sent to specific recipients it will pop up a successful message on operated PC Otherwise it will pop up a failure dialog to indicate there is an error for parameter setting 4 You may decide who will receive daily report e mail at specific duration Please enter recipient s Email Address and timer into columns Then click Apply button to set up this action You also can configure who will receive alarm e mail when event log exceeds 100 or data log exceeds 50 records Please click checkbox of selections 3 4 3 SMS This function is required to have service software available such as ViewPower Pro In the event of an alarm condition occurring a message about UPS status will be sent to the specified users via mobile phone Refer to Chart 3 8 AM ML SNMP Web Server Windows Internet Explorer L If Go l http 192 168 107 109 E E 4s oc E Live Search e File Edit View Favorites Tools Help Ue Favorites sne Web Server e x Ca dh Pager Safety Tools e 3 SMS Information SMS server 192 168 107 11 i Port 41222 cet Urs sein Account EE AAT ae Mm Ap e PRS m 7 lt 7 Parameters setting
13. light saving time No v System Time mm dd yyyy hh mm ss 05 23 2013 10 16 07 Apply Auto Restart System for Every 0 Disable lo Minute s Apply Manual Restart System After 30 Seconds Apply o internet o 100 Chart 3 13 e Automatic time correction interval e Time server The SNTP server IP address or domain name e Time Zone Relative to GMT e Applying daylight saving time e System Time mm dd yyyy hh mm ss It is to set up SNMP web local host time Auto Restart system for Every 0 Disable XX Minute s e Manual Restart system after 30 Seconds When click Apply button SNMP will restart after 30 seconds 3 4 9 SNMP configuration Setting SNMP web card basic information such as set IP address password trap IP address SNMP UDP port and Restore the factory settings Note Some operations will cause SNMP to reboot It s normal operation Select System Configuration gt gt SNMP configuration Refer to Chart 3 14 AM MLL SNMP Web Server Windows Internet Explorer EIE E htto 192 168 107 109 ve Search EE WE File Edit View Favorites Tools Help r Favorites sue Web Server ma S mde Page Safety Tools e 3 i P C EAE dA Me DN 2 Wah Cariar n S NI VF Wep Sel Ver 20 System will reboot when this item has been Applied IP address e G Automatically obtain IP address s ES Ouse a static IP address aramete
14. m at bypass mode Enable Disable Apply Green power function Enable Disable Apply UPS setting aim Alarm at battery mode Enable Disable Apply Cold start Enable Disable Apply Alarm control Enable Disable Apply d Auto reboot Enable Disable Apply Yes necs O Enable 9 Disable Control Battery deep discharge jen Bypass when UPS is off O Enable Disable Apply protection Enable Disable tem configuration Converter mode O Enable Disable Apply Site fault detection O Enable Disable PPly Web ECO mode O Enable Disable Apply P1 programmable outlet Enable Cipissbls Real time control E mail control SMS Wake on LAN Outlet settin Shutdown J Battery numbers setting Event action est iso Min Apply Numbers in parallel 3 a Apply Scheduled System time SNMP configuration Voltage and frequency range for bypass mode Voltage range for ECO mode Maximum voltage 264 jV Apply Maximum voltage 242 y Apply Eyan og Mini Itage 170 ly Apply e Data log imum voltage 170 _ V Lappy Minimum voltage 218 ly Apply aE Maximum frequency 53 Hz Apply Serial Port Debug Minimum frequency 47 Hz Apply A Internet fg Eu Chart 3 4 Note Different UPSs may access different parameter setting 1 Select the functions by clicking Enable or Disable button Change the numbers by clicking up down arrows or modify the numbers directly in the
15. number column 2 Click Apply button to save the settings Each function setting is saved by clicking Apply button in each section 3 Click Default button to recover the default setting Note Any functions which are not supported by UPS will not be able to access gt Alarm Control If enabled UPS alarm will be activated Vice versa gt Alarm at bypass mode If enabled UPS alarms when it s working at bypass mode Vice versa gt Alarm at battery mode If disabled UPS will not alarm when it s working at battery mode Vice versa gt Auto reboot If enabled UPS will auto recover when AC is recovering Vice versa gt Bypass when UPS is off If enabled AC will directly provide power to connected devices when UPS is off Vice versa gt Converter mode If enabled the UPS will operate in converter mode Vice versa gt ECO mode If enabled the UPS will operate in ECO mode when input voltage is within acceptable range Vice versa gt Battery open status check If enabled the monitored UPS will check if the battery connection is ok or not when UPS is turned on 38 P PowerWalker gt Cold start If disabled the UPS can be turned on only when AC is normally connected to UPS Vice versa gt Bypass not allowed If enabled the UPS will not transfer to bypass mode under any conditions If disabled the UPS will be allowed to transfer to bypass mode according to UPS internal setting gt B
16. occurs When clicking this checkbox it will send alarm E mail when any event occurs on the local UPS e Send SMS while any UPS event occurs When clicking this checkbox in P PowerWalker the event of an alarm condition occurring a message about UPS status will be sent to the specified users via mobile phone e EMD alarming temperature upper limit Set up alarm for high temperature point If detected temperature is beyond setting value it will send alarm message e EMD alarming humidity upper limit Set up alarm for high humidity point If detected humidity is beyond setting value it will send alarm message e Data record interval xx sec Data log record the data per xx sec 3 4 7 Scheduled Select System Configuration Scheduled Refer to Chart 3 12 SNMP Web Server Windows Internet Explorer Belt G http 192 168 107 109 all MP tive search HERE Ww Favorites snmp Web Server Ea EM 3 E Page Safety Tools v e Ki SNMP Web Server 20 EE l Logat Administrator AUI l I E Information l Status Basic information Frequency O Once UPS setting C Dai Parameters setting Weekly O Monthly UPS on weekday Wednesday v Battery test scheduled Start time hh mm 1540 Method 10 second self test 9 Selftest 1 Min Shutdown cet atin O Deep discharge test Scheduled System time SNMP configuration 1 UPS On Off schedule Event l
17. og Frequency 9 Once Data log O Daily O Weekly Serial Port Debug e CT Power off at 2013 05 08 yyyy mm dd 18 A4 hh mm Power on at 2013 05 08 yyyy mm dd 4548 hb mm Use battery test scheduled Apply Use UPS On Off schedule Apply e KA Internet Chart 3 12 e Scheduled battery self test Scheduled battery self test can be executed once daily weekly or monthly Users can select UPS and time parameters It is recommended to set only one action in the same time If multiple actions have been applied at the same time some of these actions may be ignored Any action will be ignored when the action is not supported by the UPS e Scheduled UPS on off Scheduled UPS on off can be executed once daily weekly Users can select UPS and time parameters It is recommended to set only one action in the same time If multiple actions have been applied at the same time some of these actions may be O ML ignored Any action will be ignored when the action is not supported by the UPS 3 4 8 System time Select System Configuration gt gt System time Refer to Chart 3 13 r SNMP Web Server Windows Internet Explorer ER GO gt E 192 168 107 122 Fie Edit View Favorites Tools Help dy Favorites SNMP Web Server Automatic time correction interval 12 Hours v D D Time server time nist gov Time Zone Relative to GMT GMT Applying day
18. om step 1 see chart 1 1 Chart 1 1 Refer to chart 1 2 for connecting the SNMP web card Step 3 Plug Ethernet cable to the Ethernet port RJ 45 on the SNMP web manager Step 4 Use one more Ethernet cable Connect one end to the sensor port on the SNMP web manager and the other end to the optional environmental monitoring device Connects to Environmental Monitoring Device Chart 1 2 O AZZ 1 5 Configuration a Please install SNMP web manager wizard in your PC After software is installed successfully the Installer will leave a shortcut icon on your desktop m d ot SHMP Web Chart 1 3 b Enter specific IP address to search all SNMP devices in LAN The SNMP web manager will automatically collect the IP address from sever by default via a DHCP server It will apply default IP address of 192 168 102 230 default subnet mask as 255 255 255 0 and default gateway as 0 0 0 0 without a DHCP server System Settings Language Help ress IP address H MAC add 182 158 107 78 00 00 5E 00 1 0 23 Basic Info IP settings Online upgrade System manager Static trap address IP address 1924 68 107 79 MAC address 00 00 5E 00 10 23 SNMP status 1 _ SNMP reset enable Use system time 08 17 2012 16 42 01 Apply Output window 182 158 107 15 42 00 192 168 107 79 Online successfully
19. orites Sr Web Server En i C geh Pager Safety Toos 3 Event log Information Time Event name 05 08 2013 15 44 01 Scheduled UPS power on off is going to start Battery self test completed Battery self test is going to start System configuration 1 Clear Save as E e Internet Chart 3 15 3 5 2 Data Log In the Data Log window it will list all history logs and can be save as csv file Refer to Chart 3 16 Select Log gt gt Data log 7 SNMP Web Server Windows Internet Explorer BEL Ge gt bttp 192 168 107 122 JR s ox BF Live search lei File Edit View Favorites Tools Help ye Favorites sw Web Server f D C3 d Page Safety Toos A Data log Information Time Input voltage V Output voltage V Output frequency Hz Load Battery voltage V Temp TC 5 23 2013 10 18 00 210 0 29 7 5 bo H UPS setting 0823200 107002003 2297 ns s mo M4 05 23 2013 10 15 002090 gme8 oo 2 on Di 05 23 2043 1013590096 9296 500 3 op D03 os232013 1012582086 2397 boo b mo wm 5 23 2013 10 11 58 209 9 00 5 ban m3 5 23 2013 10 10 5 98 41 403 5 23 2013 10 09 5 9 6 2 7 ce ce e elc eo co 5 23 2013 10 08 5 5 23 2013 10 07 5 29 5 23 2013 10 06 58 209 1 5 23 2013 10 05 5 5 23 2013 10 04 562090 2297 c oO cec Co co ce c v L Internet fm 100 7 Chart 3
20. re programming data and scheduled shut down the UPS All UPS warning and fault event records can be kept in SNMP web card Integrated with ViewPower Pro software it can monitor and remote access all distributed SNMP web card in a LAN or INTERNET For the detailed operations please check user manual of ViewPower Pro 2 Features 1 gt Open monitor via Web Browser gt Offer SNMP MIB to monitor UPS status Automatically detect and exchange 10M 100M Fast Ethernet Support wake on LAN function Supported protocol such as TCP IP UDP SNMP SMTP SNTP HTTP and so on Integrated with Shutdown Wizard it can prevent data loss from power outage and safely shut down systems gt Support to record and export event log including UPS warnings faults and EMD warnings gt Support to record and export data log Support daily reports for event log and data log gt Scheduled UPS on off and battery test v 1 3 Overlook Ethernet port 10 100Base T O Sensor port e Golden finger connects to UPS slot Ethernet port status LEDs SNMP I SNMP II Only for 3 phase online UPS 3388 P PowerWalker Ethernet port status LEDs Off Off 1 4 Installation and Connection Follow below steps to install and connect the SNMP web card Step 1 Remove the cover of intelligent slot on the back panel of UPS and retain the screws Step 2 Slide the card into the open slot and secure with the screws fr
21. rites suwP Web Server Til Ee lt E E D v Pager Safety Tools e A Alarm control UPS turn on off Battery self test 10 second self test Deep discharge test Minute self test 0 2 Min uma GALE Crit t e KA Internet Chart 3 5 You can real time control the UPS by executing following operation UPS turn On Off Click On to turn on the UPS and Off to turn off the UPS immediately gt Battery Self Test It offers three types of battery self test 10 second self test deep discharge test and self defined self test Simply clicking Start button from each type It will execute the self test immediately 3 4 System configuration 3 4 1 Web user It configures the authority to access SNMP web card Please enter access ID and password in each column There is no any limitation to access control in default setting Refer to Chart 3 6 Q Power Walker SNMP Web Server Windows Internet Explorer Sees sc D n X My Live Sear h IER Up Favorites snmp Web Server fp gt E Cl de Page Safety Tos 23 CNMP W e eC AC P N SINMr VVCL e Ver 20 Web Administrator information User Account User Name Password Permission Operation B No Access 2 Apply Delete i E Ert aa Serial Port Debua _ serial Port Debug e KA Internet Chart 3 6 3 4 2 E mail Its allowed to send
22. rs setting ion 168 107109 Control Subnet mask 255 255 255 Default gateway 192 168 16 DNS Apply Password eel Old password New password Confirm password Trap IP address Trap IP address 1 0 0 0 0 Trap IP address 2 0 0 0 0 Trap IP address 3 0 0 0 0 m fa 100 s Chart 3 14 IP address There are two methods to obtain IP address 1 Automatically obtain IP address DHCP default 2 Manually configure IP address The system will default automatically obtain IP addresses If there is no this kind of service provided in LAN the default IP will display as 192 168 102 230 Net mask as 255 255 255 0 and default gateway as 0 0 0 0 Password Modify the password The length of password is 8 15 digits Trap IP address The SNMP device could provide 4 static trap addresses SNMP UDP port You may change SNMP port and trap port Restore the factory settings Note The system will default automatically obtain IP addresses and default Password is 12345678 3 5 Log 3 5 1 Event log In the Event Log window it lists all history events and can be saved as csv file The event log includes UPS warnings fault info and EMD warnings Refer to Chart 3 15 Select Log gt gt Event log 7 SNMP Web Server Windows Internet Explorer Go e http 1 192 168 107 109 ined x My Live Search Uy Fav
Download Pdf Manuals
Related Search
Related Contents
前処理アクセサリー | Restek GCカラム&アクセサリーカタログ NOTICE PHOENIX STII-BXII - MRC Una Untitled Mode d`emploi du logiciel CxF3_to_CGATS Rev.2 Handbuch - Opel Schweiz 64 64 CUPROTAL ECO Cobre Quelatado DPY 8405 GXHB2 Dryer User Manual Сушилнята Ръководство за • No dejar los envases cerca de los alimentos ni bebidas Copyright © All rights reserved.