Home

Spiromatic Face Mask and breathing valve User manual

image

Contents

1. Spiromatic Face Mask and breathing valve User manual Contents Safety 4 Mask and breathing valve 5 Checking before use Leakage test Putting ON the cenkawerseeens 7 Testing of positive pressure Affer USE 8 Removing the mask Mask and breathing valve 9 Dismantling Cleaning and disinfection Assembly after cleaning Function test after cleaning Visual inspection RecommendaAfionS 12 13 Service and testing 13 The Interspiro QS S Face mask has been tested in accordance with EN 136 and EN 137 for types of use specified EC type examination Directive 89 686 EEC by SGS United Kingdom Ltd Weston super Mare BS22 6WA UK Notified Body No 0120 Safety notice The product must only be used with An approved Interspiro breathing apparatus SpiroGuide QS system or 90 U The product must only be used together with an approved Interspiro breathing ap paratus or airline system The product must only be used by personnel in good health and trained in the use of respiratory protective equipment Individuals with beards or large sideburns may not obtain an adequa
2. MAIL infouk interspiro com SCANDINAVIA ASIA PACIFIC amp MIDDLE EAST SWEDEN NORDIC amp EXPORT SALES DIVISION www interspiro com Box 2853 S 187 28 TABY SWEDEN TEL 46 8 636 51 00 FAX 46 8 636 51 99 E MAIL info interspiro com MALAYSIA INTERSPIRO Sdn Bhd www interspiro com NO 14 A Jalan Tiara 3 Tiara Square Taman Perindustrian Sime UEP 47600 Subang Jaya Selangor MALAYSIA TEL 603 802 482 21 FAX 603 808 182 21 E MAIL asiapacific interspiro com 96784B01
3. apparatus has been exposed to extreme conditions such as A extreme heat or cold harsh liquids or chemicals heavy duty dust particles or extreme shock or vibration the apparatus must undergo a test and in spection by a holder of an INTERSPIRO Service Certificate REMOVING THE MASK 1 Close the positive pressure by turning the lever against the valve house 2 Open the head harness buckles and loosen the straps 3 Remove the mask MASK AND BREATHING VALVE DISMANTLING 1 Disconnect the breathing hose 2 Remove the cover the speech cone or radio interface by loosening the two screws 3 Turn the breathing valve clockwise so that it comes away from the bayonet fitting and pull the valve outwards 4 Dismantle the breathing valve as follows a Unscrew the locking ring and remove the positive pressure unit from the valve housing b Seal off the connection nipple and the inlet channel with rubber plugs c Carefully remove the diaphragm assembly from the cover by squeezing the thread of the cover d Remove the positive pressure spring and the guide disc from the cover e Remove the sealing disc from the dia phragm assembly Note Do not dismantle the diaphragm assembly any fur ther Further dismantling of the breathing valve should if necessary only be carried out by a specialist If sand or dirt has entered the valve seat the valve must for reasons of safety be dis mantled and cleane
4. d Before use it must be checked with a suitable test device 10 CLEANING AND DISINFECTION Attention Observe that the equipment may become contaminated by infected body fluids Always follow the policy prescribed by your organisation Interspiro recommends that the face mask is cleaned and disinfected by following the pro A cedure described below If the face mask is shared between different individuals it is advisable to follow this procedure after each use Solvents hot water and detergents containing perborate must not be used because the rubber and plastic materials can be damaged 1 Wash the face mask and the dismantled breathing valve in lukewarm water with a mild cleaning agent or soap In the event of heavy contamination a brush can be used 2 Rinse in clean water 3 If necessary disinfect the mask and the breathing valve Use a disinfectant solution Thor oughly rinse all the disinfected parts in clean water Recommendations For cleaning solvents Interspiro recommends Spiroclean for cleaning and Spirodec plus for disinfection 4 Let the parts dry Temperatures higher than 50 C must not be used for drying 5 Remove the rubber plugs from the valve housing and check that no water has entered the inlet side of the breathing valve If water has entered connect the valve to an apparatus and switch on the positive pressure in order to blow out any remaining water ASSEMBLY AFTER CLEANING All the parts should be
5. dry before reassembling 1 Place the guide disc with the sealing spring in the cover Do not straighten the spring The slight bend is intended 2 Assemble the sealing disc and the diaphragm assembly Check that the sealing edge of the diaphragm and the edge of the sealing disc is even and clean 3 If necessary lubricate the sealing edge and the sealing area of the sealing disc with lubricant If needed the O rings should be lubricated Lubricant can also be applied to the groove for O ring in order to keep the O ring in place 4 Place the diaphragm assembly on top of the spring and push it down into the cover Do not twist as the spring tension could be altered 11 5 Check that the unit is working correctly by pressing down lightly on the guide pin a few times The diaphragm assembly should move freely 6 Place the locking ring on the valve housing and screw on the positive pressure attach ment 7 Check that the guide pin of the positive pressure attachment is correctly placed in the slot of the lever fork 8 Mount the breathing valve onto the face mask and replace the cover speech cone or radio interface FUNCTION TEST AFTER CLEANING 1 Connect the SPIROMATIC Mask to the regulator unit and air cylinder and turn the lever to the off position against the valve housing Open the cylinder valve No flow of air should be heard A flow would indicate a leakage 2 Put on the face mask and check that the positive pres
6. ds the valve housing 2 Open the cylinder valve and check the pressure on the pressure gauge 3 Open the positive pressure by turning the black lever away from the housing A strong flow of air should be heard 4 Turn off the positive pressure and read off the pressure gauge Close the cylinder valve The pressure should not fall more than 10 bar during one minute Any leakage in excess should be repaired by a Interspiro Service Certificate holder PUTTING ON THE MASK 1 Put the neck strap around the neck When the mask is not used turn the mask as shown in the picture to avoid dirt entering the breathing valve 2 Check that the positive pressure is turned off and open the cylinder valve Check the pressure 3 Pull the straps over the mask and put the mask to the face Be careful that no hair is caught between the mask and the face 4 Pull the straps over the head 5 Tighten the straps If they are too lose the mask will not seal properly 6 Take a breath to turn on the positive pres sure TESTING OF THE POSITIVE PRESSURE 1 Hold your breath and listen for any leak ages If there is a fitting leakage check that hair has not come between the mask and the face and adjust if necessary the head harness 2 Check the positive pressure function by holding the breath and inserting two fingers between the sealing edge and the face a strong air flow should be heard After use Warning If the
7. elow 0 C it is essential that the apparatus is dried thoroughly before storage The breathing valve should be stored with the black lever turned away from the valve hous ing Service and testing schedule Service and testing shall be performed according to Service and testing schedule 97307 Visit www interspiro com for latest revision 13 INTERSP IRO CENTRAL EUROPE NORTH amp SOUTH AMERICA www interspiro com may AUSTRIA INTERSPIRO GesmbH www interspiro de Feldbacher Str 3 A 8200 GLEISDORF AUSTRIA TEL 43 0 311 236 133 FAX 43 0 311 236 133 22 E MAIL info interspiro at GERMANY INTERSPIRO GmbH www interspiro de Postfach 1220 D 76691 FORST BADEN GERMANY TEL 49 0 7251 8030 FAX 49 0 7251 2298 E MAIL info interspiro de SWITZERLAND INTERSPIRO AG www interspiro de GiiterstraBe 47 CH 4133 PRATTELN SWITZERLAND TEL 41 61 827 99 77 FAX 41 61 827 99 70 E MAIL info interspiro ch THE NETHERLANDS amp BELGIUM INTERSPIRO BY www interspiro nl Operetteweg 35 NL 1323 VK ALMERE NETHERLANDS TEL 31 0 36 5363103 FAX 31 0 36 5384809 E MAIL infobv interspiro com INTERSPIRO Inc www interspiro com 10225 82nd Avenue PLEASANT PRAIRIE WI 53158 5801 USA TEL 1 262 947 9901 FAX 1 262 947 9902 E MAIL sales interspiro com UNITED KINGDOM amp IRELAND INTERSPIRO Ltd www interspiro com 7 Hawksworth Road Central Park TELFORD Shropshire TF2 9TU UNITED KINGDOM TEL 44 0 1952 200 190 FAX 44 0 1952 299 805 E
8. sure is switched on automatically by the first inhalation A strong flow of air should be obtained Ifnot the valve has been wrongly assembled and should be adjusted and the test repeated 3 Turn off the positive pressure the black lever against the valve housing and take off the mask before exhaling Wipe the edge of the face mask with disinfectant For a more comprehensive function test an INTERSPIRO test unit should be employed VISUAL INSPECTION Inspect the rubber parts the plastic parts the non return valves in the inner mask and the head harness at regular intervals If any part is defect or damaged the apparatus must be repaired and checked by INTERSPIRO or a holder of an INTERSPIRO service certificate before it can be used again Recommendations A breathing apparatus for work in contaminated atmosphere shall undergo a complete func tion test at least once a year even if it has not been used Such tests are carried out on an INTERSPIRO test equipment For more detailed service and repair work regular courses are held where participants are trained to become authorized servicemen and will receive a Service Certificate Storage The apparatus should be stored in a cool dust free and dry place Rubber parts must be protected against direct UV radiation grease and oil The breathing valve should be stored with the black lever turned away from the valve hous ing A Warning If the apparatus is to be stored at temperatures b
9. te seal The face mask must be maintained serviced and tested as described in this user manual Interspiro service manuals and Interspiro test instructions INTERSPIRO IS NOT RESPONSIBLE FOR MAINTENANCE AND REPAIRS DONE BY PERSONS WHO DO NOT POSSESS A SERVICE CERTIFICATE ISSUED BY A INTERSPIRO COMBINATIONS OF PRODUCTS UNLESS THE COMBINATION IS PART OF THE TEST CERTIFICATE CHANGES OR ADAPTATIONS MADE TO THE PRODUCT BY A THIRD PARTY Changes to this document necessitated by typographical errors inaccuracies of cur rent information or improvements and changes of equipment may be made at any time without prior notice Always refer to www interspiro com for product updates docu ment updates and service bulletins Exposure to extreme conditions such as asbestos may require other actions than described in this manual The guarantees and warranties specified in the conditions of sale are not extended by this Safety Notice MASK AND BREATHING VALVE 1 Connect the breathing valve to the mask by pushing the valve into the connection piece and by turning it anti clockwise so that it grips in the bayonet coupling 2 Mount the cover speech cone or radio interface Savox in the face mask Tighten the screws by hand 3 Connect the SPIROMATIC mask to the breathing hose and tighten the union nut by hand CHECKING BEFORE USE Leakage test 1 Close the positive pressure by turning the black lever of the breathing valve towar

Download Pdf Manuals

image

Related Search

Related Contents

  Dell Latitude C840 Quick Setup Guide  instructions manual_te806  2013-07 - Recinto del Pensamiento  und Aufstellanleitung  Manual - English  KDL-40SL150 - Webcollage Content Publisher  655 - Gemü soluções em válvulas de diafragma industriais..  Heaven sent - Phone house  Retriever™ 6250 SR 1800 - Caliber Equipment Inc.  