Home

user manual - Grote Software Systems

image

Contents

1. kk e 17 4 3 4 Measurement Catenary wear OUt LLL keke kk keke kek KK K KEK KAK K KAK KAKA 18 4 4 BEE EE EN g rrer h rer 0 J 20 4 5 BEG EDOT EE ane ne EE ee ae ere ree ene re rr rrr 22 4 6 Mo reze 0 O 25 4 7 PD 25 4 8 SE EE EE NE manta 26 4 9 FAE NNN 30 5 Troubleshooting Hotline rrrrsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnenn 30 6 ML 31 Version 3 0 12 1 03 31 2013 Ge Grote Software Systems 1 Introduction Thank you for purchasing the software FMcapture With this product you can achieve a significant improvement in the range of use and operating with the catenary measuring instruments from the company Feinmess Dresden GmbH e With the software FMcapture you can describe the height of catenary the location to the track axis sine or zigzag and the catenary wear digital recording with up to three attributes name can be chosen These attributes can be powered with external data series The data transfer is done via a Bluetooth radio link e Optionally the triggering of a measurement via a soft key from within the software is possible a blurring is no longer possible and a more accurate measurement can be performed e The software FMcapture can be used by multiple users projects separately Furthermore a password protection is also available e You can use a desktop PC a notebook or a tablet PC as hardware e You get
2. in 28200in se in l Tendon left Single No 1 57 087 in RiSi20 mi Mark On No 1 57 087 in RiS120 vi Mark On tj COM4 On DISTO TM 8 512345678 ey Grote Software Systems tj g COM4 On DISTO TM 8 512345678 i Grote Software Systems With the softkey Wear out you start the measurement of the catenary wear out First the left tendon edge is measured You can make the laser pointer visual via the softkey Marker On Off to find the exact position of the tendon on the left edge In the remote mode just one measurement is triggered in the multi mode it is measured as long as the softkey Measurement is activated again Without the option of the remote operation you have to make the actual measurement and data transmission at the catenary measuring system With the softkey Tendon left you save this value into the data buffer of the software mi FMcapture 3 0 Data Recording EM mi FMcapture 3 00 Data Recording EM mi FMcapture 3 0 Remote control On manual 31 02 00000282 v Fire ea Back C FMcapture Data Data_manual FM0406A18 fmd street Main Street v devision Poles v line Line 1 v Save X Cancel Measurement mode Wear out Tendon right mark and measure position Catenary hight 17 596 ft A Height from left from right sinus inclination Ri Catenary position 1 908 ft 2 849 ft 5 65 in 1 52 Position gt Distance to PLE 12 164 ft A PLE O Muti Tendon left Tendon right Catenary wear
3. 5 Troubleshooting Hotline If you receive an error message while starting FMcapture or the program does not run properly it indicates that the installation files are deleted accidentally or they are defective In that case run a repair from the setup of FMcapture as described in 3 2 Repair If the error still occurs please contact the hotline including the following information information about the operating system license number serial number any error code error description your contact details AN Please send your request only via e mail to grote software systems ewetel net Upon receipt of your email you will receive an answer immediately or we will call you 30 Version 3 0 12 1 03 31 2013 6 Ge Grote Software Systems Imprint Each version of FMcapture is a single user version It is not allowed to copy distribute or sell it in any other form to third parties without the consent of the company Grote Software System All rights to the software FMcapture logos icon or other publications on software FMcapture are protected by copyright for the company Grote Software System 28832 Achim Germany Reproductions in any form are not allowed to be done without the explicitly written permission of Grote Software System cg Grote Software Systems Am K sterhof 10 28832 Achim Germany e mail grote software systems ewetel net internet www grote software systems de Copyright 2013 Grote Softwa
4. N Grote Software Systems FMcapture user manual Ge Grote Software Systems Content manual FMcapture for FMcapture 3 0 Windows XP Windows Vista Windows 7 and Windows 8 version 3 0 12 1 03 31 2013 Version 3 0 12 1 03 31 2013 Ge Grote Software Systems Content 1 Moda Vrccrtrw rrww lt cc ec rc ww r w ww wWaaarrr r o ox 4 1 1 Copyrights and TrademarkKSs keke eee ke keke keke KK keke KEK KK KEK KAKE KK A KK 4 2 System Requirements L keke keke kake kk kek KK KEK KEK KK KK KEK AKA K KAKA KAK KK K KK KK KK KK KA 5 2 1 Desktop PC Notebook and Tablet PC rarrrrnnnnrrrnnnnnrnnnnnnnrnnnnnnrrnnnnnernnnnnernnrnnnnnnnnnnevnnnnnesennnnssseennn 5 3 Installation Setup OPtiON wvicsisicrsisiinisncesissacacsscssnccssvensssneedancestnansnoniiaaecsnenenssesinbeseskseanaankeanssannnetes 6 3 1 SVS CAN ODM EE EE EE e202 6 3 1 1 First Segment License Request Lunnan 6 3 1 2 Second Segment Program Installation Eke ke 8 3 2 LET TT EEE EEE RE 9 3 3 VASER ea 10 4 PINNE ccc ee cise el l r e y rypr lt e gt ewJ_ r zz 12 4 1 Program start SH HHHH HHHH HHHH HEE EE DIN 12 4 2 NE 12 4 3 DAR 13 4 3 1 Measurement Catenary height kk ey k ke Kek KK KA 15 4 3 2 Measurement Catanery position L Ek kk kek kek kek kK KK KK RA 16 4 3 3 Measurement Distance to PLE PoleLeadingEdge
5. ZigZag and select a track gauge You can enter an own track gauge Attention All values of catenary and rail are in mm Note This data is used during data recording for all calculations All this values cannot be changed there Version 3 0 12 1 03 31 2013 29 Ge Grote Software Systems e Tab Device FMcapture 3 00 Settings Ee FMcapture 3 0 a Back Data Recording Data Data Export Attributes Com port User Catenary Rail Device Offset adjustment Offset for height y axis Offset for position x axis Sin 4in Unit of measurement metric measures m cm mm imperial measures yd ft in Degrees Celsius C Degrees Fahrenheit F Remote control V Remote control with software Beep J Beep when receiving data Inclination correction Height meassurment MVK meassument cg Grote Software Systems Under the tab Device all basic values for the measurement are set You can specify the offset for height measurement Y axis and position measurement x axis Please pay attention to the details for the relevant catenary measuring system You can choose the unit systems you can activate deactivate the remote control and choose a tone when receiving data You can also choose a height correction 4 9 Finishing You can close FMcapture in two different ways Once with Exit in the Start Menu and the other with the Windows close button
6. System Also a note to all used trademarks is displayed With close you leave the info area mi FMcapture 3 00 Info oe mi FMcapture 3 0 manual aa Close FMcapture 3 0 f r Windows XP Vista 7 und 8 Build 3 0 12 1 copynght Feinmess Dresden GmbH licensed for name of Your company institution Your zip code Your City license number P4PJK 5DQC4 URSWS 93PM6 N45Q6 This product is a single user version It is not allowed to copy it or to give it in any other from to third parties without the agreement of the company Grote Software Systems All rights to the software FMcapture are owned by the Company Grote Software System with its seat in 28832 Achim Germany Copyright 2013 n Grote Software Systems cg Grote Software Systems 4 7 Help To assist the software FMcapture this user manual is available as PDF file You can start this manual under Help You can also find the manual in the installation folder from FMcapture under FMcapture gt Manual named FMcapture 3 Manual 002 pdf ex Grote Software Systems FMcapture user manual Note The current version of the user guide can be found at the following website http www grote software systems de under Download gt FMcapture gt Manual 25 Version 3 0 12 1 03 31 2013 Ge Grote Software Systems 4 8 Settings In Settings you can set various preferences These settings will be taken when leaving the me
7. remote operation you have to make the actual measurement and data transmission at the catenary measuring system The measurement of the inclination shows the banked track axis camber x E EE g With the softkey Save you stop the measurement of the catenary position and insert the data into the data buffer of the software You can now perform the measurements in the other measurement modes You can take a new measurement of the catenary height at any time before you save the record Now you can even if no further measurement mode has been used save the record finally yet and jump automatically to the next record This process cannot be cancelled 16 ee Version 3 0 12 1 03 31 2013 Ge Grote Software Systems 4 3 3 Measurement Distance to PLE PoleLeadingEdge x mi FMcapture 3 0 Remote control On With the softkey PLE you start the measurement of the distance of the catenary track axle to the fattening front edge of the catenary pole In this case depending on the option selected in Settings the distance from the catenary position or the track center to the front edge of the catenary pole is measured in the target direction of the laser For the opposite catenary the catenary measuring system has to be rotated by 180 In the remote mode just one measurement is triggered in the multi mode it is measured as long as the softkey Measurement is activated again Without the option of the remote operation y
8. the software FMcapture on CD DVD here you can find the setup with the following options Install Repair and Remove The user manual is also included on the disc Please always run the setup options from this original disk and always store all updates as a backup e You will be informed about potential changes per e mail newsletter or you search for current information and updates for the software FMcapture under www grote software systems de e You can assign all measurements to individual projects The name and location of the data files can be chosen freely or use the default parameters You can see all recorded data at a later date change attributes print data in different formats delete individual data or you can export measurement data Many choices locations or information requests are user adjustable Here you can also rely on their own data files and templates Furthermore you can create and manage user profiles and different other things All settings and attributes for the user are saved here e The company Grote Software Systems is not liable for performance issues failures or data loss of any kind e Please store your manual carefully The hereby marked passages are important instructions in the manual 1 1 Copyrights and Trademarks The following brands are subject to copyright protection and are protected by national international rights e FMcapture is a trademark from the company Grote Software Systems e
9. the start happens directly from the desktop linkage via double click As a further option you can also find FMcapture 3 0 under programs and you can start it here via double click too In Windows 8 a tile is placed on the home screen for disposal For Windows Vista Windows 7 Windows 8 you have to permit the application of FMcapture30 exe explicitly User Account Control Don t run the program unless you know where it s from or you ve used it before MFcapture30 exe m e 3 Unidentified Publisher Program name FMcapture30 exe gt Cancel Publisher Unknow I don t know where this program is from or what it s for File origin Hard drive on this computer gt Allow I trust this program I know where it s from or I ve used it before V Show details Yes N v Details Change when these notifications appear User Account Control helps stop unauthorized changes to your computer Windows Vista Windows 7 Windows 8 After starting for about 3 seconds an info window will appear Splash then you will go for the user control Here the last user project or FMcapture as factory setting default at the first start are displayed For continuation of the program a password entry is required The factory setting default at the first start is the password 11111 otherwise the respective password for the user project input If a user project is created without a password in this step no password entry is re
10. 2 1 03 31 2013 Grote Software Systems With Apply the chosen setting for the measurement items is accepted x Ge gt LL LL ETE ee HET n MK MK e w n n e T D In the next step you need to set the export format This selection can be changed at any time before the actual export After setting the export format the name for the export file is displayed It is always the name of the open FMcapture data file The extension corresponds to the selected export format You can specify your own file name You can simply overwrite the suggested file name At the same time the file path is displayed By default the location of the file path is always the Export folder in the installation path of FMcapture The user export folder is created at the first time exporting data If you want to choose a different location you can make your own selection with Save As x T gt Computer gt GSS E v Search GSS E mi FMcapture 3 0 Organize v New folder Z v i Name Date modified Type G Libraries A Project_FMcapture 3 27 2013 3 55 PM File folder Co PEST a Music l Pictures Ei Videos mo erime anrbutes Ge post pos sne inc naton wearout wearou tendon tendons LE ETI n VE FIT EEK CSVile esv o oy amp Homegroup HE gt v Save as type text file txt txt v Hide Folders For the export format text file you can als
11. DISTO is a trademark of Leica Geosystems GmbH e Bluetooth is a worldwide registered trademark of Bluetooth SIG Inc e Microsoft Windows XP Microsoft Windows Vista Microsoft Windows 7 and Microsoft Windows 8 are a worldwide registered trademark of the Microsoft Corporation e Microsoft Excel is a worldwide registered trademark of the Microsoft Corporation Version 3 0 12 1 03 31 2013 2 System Requirements Ge Grote Software Systems 2 1 Desktop PC Notebook and Tablet PC Processor Main memory HDD memory Drive Graphic card Operating system Add ons Software D Not included 800Mhz or better 128MB or better 20GB or better CD DVD drive 256MB or better Microsoft Windows XP Microsoft Windows Vista Microsoft Windows 7 Microsoft Windows 8 except Windows 8 RT Bluetooth adapter vy Microsoft Net Framework 3 5 installed and or activates Microsoft Excel Version 2005 2010 Microsoft Office 2005 2010 with installed Excel Version 3 0 12 1 03 31 2013 UT Ge Grote Software Systems 3 Installation Setup Options 3 1 Installation The installation of FMcapture is generally issued in two separate operation steps The installation process is divided into two sections the first manages the license request and the second installs the actual program This requires that you run the setup for two times The license request is made through a license
12. Tab Com port x 0 are default values for Leica DISTO TM 8 Under the tab Com port you can configure the COM port All settings for the catenary measuring system DISTO series have been configured by the setup only the COM port still has to be selected For this purpose all available COM port not only physical ports are displayed in this selection field Select the appropriate COM port for your connection to the catenary measuring system Tog 1 Version 3 0 12 1 03 31 2013 e Tab User Ge Grote Software Systems mi FMcapture 3 0 Kn Back Data Recording Data Data Export Attributes Com port user save settings name users type FMcapture 3 00 Settings load settings name for user to choose Clear Preferences name for user to choose Catenary Rail Device E gt Default ke Load cg Grote Software Systems Under the tab User you have the option to assign your current settings to a corresponding user profile or to load an already existing user profile or to delete one of these To save your settings enter a user name in the appropriate field and save it If the username is already used you will be alerted and can choose whether you want to overwrite it or choose a different username You can choose a password or you can create a user without a password When you choose a user with a password you must write the password in both fields
13. To load a user profile select from existing users of the entry and with Store this user profile is applied A security query prevents accidental overwriting of the current user profile If the user is loaded the user name will be adjusted accordingly If the user is created with a password you have to write the password in the field To delete a user select the user name and enter the password after a safety query now you can delete the user AN Attention This process cannot be undone AN Note If the user is created without password protection eliminates the input of the password when a user is loaded or deleted e Tab Catenary Rail mi FMcapture 3 0 Back FMcapture 3 0 Settings Data Recording Data Data Export Attributes Com port User Catenary Rail Device Catenary choose Note Dimensions in mm AC120 CuAg0 1 RiS120 4 0 13 2 v Catenary sinus setting choose sinus left sinus right sinus left sinus right O x Track gauge choose Note Dimensions in mm 1450 v Input of track gauge manually Note Dimensions in mm Distance measurement for PLE PoleLeadingEdge from catenary position from track axis cg Grote Software Systems Under the tab Catenary Rail all basic values for the calculations on the catenary and rail are determined You can choose the catenary type the sign of the catenary determine sine
14. With the soft key Height you start the measurement of the height of the catenary In the remote mode just one measurement is triggered in the multi mode it is measured as long as the softkey Measurement is activated again Without the option of the remote operation you have to make the actual measurement and data transmission at the catenary measuring system The measurement of the inclination shows the banked track axis camber AN Note If the option tilt correction under Settings is selected an angle icon appears next to the measured value The measured value is corrected in relation to the slope of the transverse axis and is saved With the softkey Save you stop the measurement of the catenary height and insert the data into the data buffer of the software You can now perform the measurements in the other measurement modes You can take a new measurement of the catenary height at any time before you save the record Now you can even if no further measurement mode has been used save the record finally yet and jump automatically to the next record This process cannot be cancelled 115 tt gt Version 3 0 12 1 03 31 2013 Grote Software Systems 4 3 2 Measurement Catenary position With the softkey Position you start the measurement of the catenary position In the remote mode just one measurement is triggered in the multi mode it is measured as long as the softkey Measurement is activated again Without the option of the
15. a manual Organize v New folder Er Downloads Name Date modified Type S Recent places SkyDrive Libraries Documents 2 Music Pictures E Videos amp Homegroup jE Computer Gia Mahan di s RR i 0 sent gt File name FM0406A17 fmd vi FMcapture Datei for catenary n vi First you need to select a data file To do this click Open Now you can select a folder from your project and mark a data file Double click the file or open the file with Open The data file is loaded the file path and file name are displayed The total number of datasets and the current number of measurement data are displayed in the right pane With using the buttons and J you can navigate between your datasets Depending on the configuration under Settings gt Data now you can edit all attributes For this purpose the same selections and input options are available which are described under 4 3 Data Recording KE 1 3 Note If the option tilt correction under Settings is selected an angle icon appears next to the measured value The measured value is corrected in relation to the slope of the transverse axis and is saved Similarly you can delete individual data sets For this purpose this function must be released under Settings gt Data If this is the case the Delete button is available You will be asked explicitly if you really want to delete the dataset Caution Deleted data records are los
16. at the info bar in the middle of the window In the top of the status bar you can see the data connection status with the catenary measuring instrument The Softkey measurement is displayed The Remote Control On is then displayed in red A visual description shows you the fundamental function of the chosen mode as a help x mi FMcapture 30 Remote control On T gt Computer gt GSS E gt v Search GSS E Organize v New folder Ev SkyDrive Name Date modified Type SANE Project FMcapture 3 27 2013 3 55PM File folder brar es B Documents d Music Pictures E Videos ed Homegroup 18 Computer Ga Netanel gt File name New Data File Name v Save as type FMcapture Datei for catenary measurement fmc v You can use the predefined file path and file names or you change these settings with Save As in compliance with your wishes 113 L k_ Version 3 0 12 1 03 31 2013 Ge Grote Software Systems The predefined measurement file has got the following structure FM 0131 A 19 fmd file extension fmd FMcaptureData hours 1 to 24 index for number of measurement files per hour A to Z day month index for measurement mode FM catenary measurement Now you can describe your measuring object For this purpose there are up to three attribute fields available You can set these on your own under Settings gt Attributes or you adopt the standard setting with object location and
17. d external lists e Tab Data m FMcapture 3 00 Settings oR mi FMcapture 3 0 Back Data Recording Data Data Export Attributes Com port user Catenary Rail Device Delete v Individual data delete Edit v Edit data Prir t Printout list lt Printout Datasheet 4 Printout the current data Printout all of the data file cg Grote Software Systems 26 Version 3 0 12 1 03 31 2013 Ge Grote Software Systems On the tab Data you can configure the following options Delete If this item is selected you can delete individual datasets Edit Here you can edit the attribute fields Print You can choose the printing options here The following options are available printout a list printout a datasheet printout of the current dataset printout all datasets e Tab Data Export x On the tab Data Export you have the possibility to view a list of all saved export settings At the same time you can delete individual export settings which have been created by users Note Attention All export settings will be deleted also of the not accounted user e Tab Attribute m FMcapture 3 00 Settings sl FMcapture 3 00 Settings ES mi FMcapture 3 0 Jj Project FMcapture gt Testdateien gt v Search Testdateien Organize v New folder Ev IH d SkyDrive Name Date modified Type Expo
18. der the user account control please always implement the file Setup exe as administrator and allow the program to start explicitly If you are not the administrator and you do not possess the appropriate authority these requirements have to be ensured before the setup The setup program is started After short information you are requested to load the license file TRE mi Setup for FMcapture 3 0 g mi Setup for FMcapture 3 0 g n Version 3 0 12 1 03 31 2013 A 3 2 Ge Grote Software Systems Please implement the setup step by step now and end the setup after the installation First you have to load the license file which you got via email and continue the installation with Next As a next step confirm the installation with Next Now you can choose the archive location for your installation recommendation directly under the drive e g c Please choose the display size according to the used PC system This setting can be changed after the installation as well Furthermore you can choose if an icon should be shown on the desktop for a quicker start of the program lt 2 er mi Setup for FMcapture 3 0 g pr m Setup for FMcapture 3 0 g n Default large ab 1024 x 768 pixel v The installation is started with Next The setup can be completed with Exit after a successful installation of FMcapture You can always interrupt the setup in the second segment with Cancel You always get back to the previous s
19. e Setup exe as administrator and allow the program to start explicitly If you are not the administrator and you do not possess the appropriate authority these requirements have to be ensured before the setup The setup program is started After short information you are conducted to the choice of setup options Choose Remove and start uninstall with Next Setup for FMcapture 3 0 mi Setup for FMcapture 3 0 my Setup checks the installation of FMcapture now and implements uninstall While doing that you are asked again if you really want to remove FMcapture from your system 10 S Q d Version 3 0 12 1 03 31 2013 Grote Software Systems Setup for FMcapture 3 00 mi Setup for FMcapture 3 0 amp g Do you want to secure your data ES Le Furthermore you have the possibility to save your measured data before uninstall After these two queries uninstall is implemented This process can last a moment Please do not implement any operations at your system during that time You can close the setup with Exit after successful implementation FMcapture is removed from your system with all components and settings now 1 1 tt k_ Version 3 0 12 1 03 31 2013 Ge Grote Software Systems 4 4 1 4 2 12 Program handling Program start The software FMcapture 3 0 can be started from the installation file on FMcapture30 exe via double click For the used option for desktop symbol
20. e of a contact person of Your company institution not transferable rentable or sellable The copying and archiving of the program for purposes of your own data is pemitted The popety and any copytight rather proprietay tt the software remain stl the company Grote Your street number Software System and its licensing partners Pe Your zip code Your City ie poaa a ssh axay nat be caed for abr rented modified translated adapted or published It is not allowed to disassemble to decompile or to convert the whole software or parts of it back into human readable form United States 3 Duration of the contract Vour mal salen 2 Restrictions and Prohibition Your e mail address This will be the li HT nT ted Fields with are mandatory fields Grote Software Systems Grote Software Systems Please read and accept the license agreement and the conditions of use set hooks for these and click Next Please insert the requested data in the next window and click Next too mi Setup for FMcapture 3 0 mi Setup for FMcapture 3 0 n Build 3 0 12 0 Build 3 0 12 0 License request file to create Aa The requiremer t for your license file has been created and save under Save As CAFMcaptureKey a C FMcaptureKey The request file please send with an e mail to grote software systems ewetel net Please quit and restart setup after receiving the license file EE Et ie Grote Software Systems Grote Soft
21. ear out tendon 1 tendon r v DISTO TM D8 status data v measurement status data v DISTO TM D8 status data v measurement status data Pa Delete v Apply x Delete 4 Undo textile be select export format FMO406A17 3 txt filename FMO406A17 a txt file name comma semicolon space semicolon C FMcapture Export Export_manual id Seve You can then save the selected export settings under its own label to load them again For this after entering a name click Save A Note You find a list of all export settings see Settings gt Data Export here you can also remove items from the list Look at 4 8 Settings for that x mi FMcapture 3 0 3 manual da Back C FMcapture Date Data_manual load export setting Close FMQ406A17 fmd date time attributes height pos r wear out wear out tendon 1 tendon r v DISTO TM D8 status data v measurement status data X Delete 4 Undo select export format FM0406A17 txt file name semicolon cg Grote Software Systems After export you can close the open data file with Close You can leave the Data Export with Back 24 mn Version 3 0 12 1 03 31 2013 Ge Grote Software Systems 4 6 Info Under Info you will be informed shortly about the version of the software as well as about the licensee license number and the serial number of your FMcapture installation At the same time you see the note to the rights of the company Grote Software
22. ectable Excel file 2005 2010 xIsx CSV file csv t J FMcapture gt Data Data manual v Search Data_manual 2 Organize v New folder Ev IH Favorites BE Desktop B Downloads S Recent places f SkyDrive Date modified Type Libraries Documents d Music l Pictures E Videos 8 Homegroup First you need to select a data file To do this click Open Now you can select a folder from your project and mark a data file Double click the file or open the file with Open From this loaded data file the file path and file name are displayed lt Cose vun nl date time DEE KE ESN EN J me EN EE n lan KON EE ETE EN EN __wesrost __ J wesrot tendon tendone PIE rm merete j wesrout tendon tendons PIE Em L a L a E E n E n n EE pese 9 Undo With Back you quit the function Data Export all selected export settings are not saved Next you can load an existing export setting a default setting FMcaptureExport is always available By clicking on the individual measurement buttons you can build your own export format With the Undo button you can always choose a step back An exception is however the button All this allows you to select all data of the measurement entries If your choice doesn t match your ideas you can set them back at any time by deleting it and then make a new selection You can also choose the various status data 22 I Version 3 0 1
23. eft Tendon right Tendon left Tendon right Catenary wear out BR BR in Wear out Catenary wear out B BR RR in Wear out No 1 57 087 in RiSi20 No 1 57 087 in RiS120 22 4 C COM4 On DISTO TM 8 512345678 cg Grote Software Systems 3 COM4 On DISTO TM 8 512345678 i Grote Software Systems After call of the function data recording the first data from the catenary measuring system are already read and shown track gauge catenary wire type and device temperature After the first start the measurement file is set up and the first dataset is opened You can use the correlated measurement modes now Note The measurement modes can be used total or separately for every dataset An order is not relevant here A navigation of the data collection for the current mode happens through the related softkeys The available functions for the datasets are shown via the softkeys under the picture area The resolution of the measurement via software happens through the softkey Measurement and the choice of options below Basically you can run every single measurement per dataset as often as you like only with softkey Save under the picture area the measured data is saved and matched to the definite dataset After saving a dataset the program goes to the next dataset automatically this is shown by a number counter Version 3 0 12 1 03 31 2013 Grote Software Systems 4 3 1 Measurement Catenary height
24. es must be observed however according to the manufacturer description You can use the catenary measuring systems from the track level It is also possible to use the catenary measuring systems mounted on a service vehicle tower wagons manlift A Note The accuracy of the catenary measuring system has to be adjusted here at 0 0 inch m FMcapture 3 0 Data Recording a FMcapture 3 00 Data Recording 5 mi FMcapture 3 0 Remote control On mi FMcapture 3 0 Remote control On T manual manual 31 02 00001418 v ire 31 02 00000282 v Fire Fin evan C FMcapture Data Data_manual C FMcapture Data Data_manual FM0406A18 fmd FM0406A18 fmd street street Main Street v Main Street v devision devision Poles v Poles v line Ene Line 1 v zi Save X Cancel Line 1 v zi Save X Cancel Measurement mode Wear out Tendon left mark and measure position Measurement mode Wear out Tendon left mark and measure position or save Catenary hight 17 596 t A Height Catenary hight 17 596 ft AA Height from left fromrght sinus inclination from left fromrght sinus inclination Catenary position 1 908 ft 2 849 ft 5 65 in 1 524 Position gt K Catenary position 1 308 ft 2 849 ft 5 65 in 1 52 Position gt K Distance to PLE 12 164 ft A PLE O Muti Distance to PLE 12 164 ft PLE O Muti Tendon left Tendon right Tendon left Tendon right Catenary wear out _ _ ana in Tendon left Single Catenary wear out _ _
25. low I trust this program I know where it s from or I ve used it before V Show details Yes vV Details Change when these notifications appear User Account Control helps stop unauthorized changes to your computer Windows Vista Windows 7 Windows 8 Setup FMcapture 3 0 This product is a single user version It is not allowed to copy it or to give it in any other from to third parties without the agreement of the company Grote Software Systems All rights to the software FMcapture are owned by the Company Grote Software System with its seat in 28832 Achim Germany Copyright 2012 2013 for ey Grote Software Systems The setup program is started After some short information you are requested for a range of language settings first Note The standard language setting at the first time is English All available languages are offered at choice Further languages can be ordered as option and can be added but in return additional costs arise Version 3 0 12 1 03 31 2013 Grote Software Systems mi Setup for FMcapture 3 0 Build 3 0 11 0 Please select the language Engish You have to install FMcapture 3 0 selected in English Grote Software Systems Build 3 0 12 0 License Agreement and Terms of Use Please read carefully Please fill out this form 1 License name of Your company institution 0A uyer w oceve tgp ip rear ohne Zer Or an a mobie parle The right is nam
26. note Look at 4 8 Settings for that Note Minimum one attribute has to be contracted for continuing with the data recording You can choose list entries or make entries directly with a dropdown menu in all attribute fields The source and dwelling time of list entries are freely configurable for every attribute field Look at 4 8 Settings gt Data Recording and Attributes for that Start the data recoding with Start after the input of one attribute You can close the measurement file with Cancel at this point with Previous you leave the data recording without creating a measurement file mh FMcapture 3 0 Data Recording EF mh FMcapture 3 00 Data Recording og mi FMcapture 07 Remote control On mi FMcapture 60 Remote control On manual manual ea Back aa Back C FMcapture WDatalData manual C FMcapture Data Data_manual FM0406A18 fmd FM0406B 18 fmd bi Save As street street Main Street v A Main Street v A devision A devision A Poles v Poles v Ene line Line 1 v v Start X Cancel Line 1 v Save X Cancel Attributes Enter Select Next with gt Start lt Measurement mode select or Cancel Catenary hight me ft A Height Catenary hight ms ft A Height from left from right sinus incination from left from night sinus inclination Catenary position BB BB Position Catenary position __ BB it Position Distance to PLE ft A PLE Distance to PLE ft Pat PLE Tendon l
27. nu Settings with the button Back AN Note After installing the program FMcapture some settings must be configured You can save all settings the list of entries attributes and the export settings on the user control of FMcapture In the delivery condition the user FMcapture is set up as a user the same user is also set up in return to the factory setting e Tab Data Recording m FMcapture 3 00 Settings EE e mi FMcapture 3 0 manual Data Recording Data Data Export Attributes Com port user Catenary Rail Device object Content from extemal file Program content at the end delete vV Add new content place Content from extemal file _ Program content at the end delete vV Add new content comment Content from extemal file Program content at the end delete vV Add new content i Grote Software Systems In the register Data Recording the following options for the 3 attribute fields are available Content from external file read If this option is selected the list for the attribute field from an external file is copied which you can load under the Attributes tab AN Note This option is only enabled when the files are loaded Content at the end of program delete This option is only available for attributes which have lists from internal FMcapture files Add new content If this option is chosen new attributes are added both in internal an
28. o change the name of the file extensions here also just overwrite the existing entry At the same time you have the ability to change the separator 1 23 t t o Version 3 0 12 1 03 31 2013 Grote Software Systems x r x manual mg CAFMcapture Data ata manual i C FMcapture Data Data_manual zz F Close FM0406A17 fmd F Close FM0406A17 fmd s I DOS r sin no date time attributes date time attributes height pos inclination wear out tendon wear out wear out tendon tendon r al v DISTO TM D8 status data v measurement status data v DISTO TM D8 status data v measurement status data v Apply X Delete 4 Undo v Apply X Delete Undo Excelile 2005 2008 xix sss select export format CSV4ile csv v select export format FMO406A17 xisx file name FM0406A17 csv file name SaveAs CAF Mcapture Export Export_manual Bi Start For the export format Excel file 2005 2010 left and for the export format CSV right you can only change the file name If you have chosen your export settings the data file is exported with Start j x x Mi FMcapture 3 0 mi FMcapture 3 0 manual gt manual Back D CNFMcapture Data Data manual load export setting C A FMcapture Data Data_manual Cose FM0406A174md Cose FMDAOGATZ md date time attributes date time attributes pos wear out wear out tendon wear out w
29. ou have to make the actual measurement and data transmission at the catenary measuring system The measurement of the inclination shows the banked track axis camber AN Note If the option tilt correction under Settings is selected an angle icon appears next to the measured value The measured value is corrected in relation to the slope of the transverse axis and is saved x mi FMcapture 3 0 Remote control On With the softkey Save you stop the measurement of the distance PLE and insert the data into the data buffer of the software You can now perform the measurements in the other measurement modes You can take a new measurement of the catenary height at any time before you save the record Now you can even if no further measurement mode has been used save the record finally yet and jump automatically to the next record This process cannot be cancelled 117 lt kU Version 3 0 12 1 03 31 2013 Ge Grote Software Systems 4 3 4 Measurement Catenary wear out In the measurement of the catenary wear out the following procedure is carried out With the catenary measuring systems the distance between the left edge and the right edge of the tendon is measured at the bottom of the contact wire Out of this the wear out is computed as a measurement value and a percentage value is investigated according to the set catenary type The distance of the catenary measuring systems to the catenary is not directly relevant minimum distanc
30. out _ in 28 200 in in Wi Tendon right Single No 1 Mark On tj g COM4 On DISTO TM 8 512345678 ey Grote Software Systems mi FMcapture 3 0 Remote control On 31 02 00000285 v ME manual Back C FMcapture Data Data manual FM0406A18fmd street Main Street ka devision Poles v line Line 1 v mi Save X Cancel Measurement mode Wear out Tendon right mark and measure position or save Catenary hight 17 596 ft AX Height from left from nght sinus inclination Ri Catenary position 1 908 ft 2 849 ft 5 65 in 1 52 1 Position gt Distance to PLE 12 164 ft PLE Multi Tendon left Tendon right Catenary wear out _ in 28200 in 28 500 in zl Tendon right Single No 1 57 087 in RiSi20 vit Mark On J D comson DISTO TM 8 512345678 ey Grote Software Systems 18 Version 3 0 12 1 03 31 2013 Ge Grote Software Systems At second the right tendon edge is measured with the softkey Tendon right You can make the laser pointer visual via the softkey Marker On Off to find the exact position of the tendon on the left edge In the remote mode just one measurement is triggered in the multi mode it is measured as long as the softkey Measurement is activated again Without the option of the remote operation you have to make the actual measurement and data transmission at the catenary measuring system With the softkey Tendon right you save this value into the data buffer of the software N
31. ow the catenary wear out is calculated and the values are displayed accordingly x x mi FMcapture 3 0 Remote control On mi FMcapture 3 0 Remote control On 31 02 00000285 v Fire With the softkey Save you stop the measurement of the catenary wear out and insert the data into the data buffer of the software Now you can perform the measurements in the other measurement modes You can take a new measurement of the catenary height at any time before you save the record Now you can even if no further measurement mode has been used save the record finally yet and jump automatically to the next record This process cannot be cancelled After saving the record you can enter the attributes for the next record and to start the next measurement The steps 4 3 1 to 4 3 4 can now be repeated continuously With Close you close and save the current Data file The next data file can now be created With Back the current data file is saved and Data Record will be closed 119 DD gt Version 3 0 12 1 03 31 2013 Ge Grote Software Systems Data The menu Data allows you to select data from a data file to view change or delete data attributes At the same time you have the opportunity to output individual datasets or the entire data file to a printer Note Under Settings gt Data you have to make corresponding configurations for these functions Look at 4 8 Settings for that t He FMcapture Data Data_manual amp Search Dat
32. quired FMcapture 3 0 FMcapture 3 0 This product is a single user version It is not allowed User to copy it or to give it in any other from to third parties without the agreement of the company Grote FMcapture Software Systems Password All rights to the software FMcapture are owned by pen the Company Grote Software System with its seat in Cancel Ok Copyright 2012 2013 for eg Grote Software Systems cg Grote Software Systems After reviewing your information of the user control you will be redirected to the Start Menu Start Menu The start menu offers the choice of all functions of FMcapture Note Please configure your program under 4 8 Settings first Version 3 0 12 1 03 31 2013 Ge Grote Software Systems The following menu items are available Data Recording Data Data Export Info Help Settings Exit 4 3 Data Recording At Data Recording you can record measurements and annotate them with appropriate attributes The specific measurement modes catenary height catenary position distance to PLE PoleLeadingEdge and catenary wear out can be used optional or separately The connection to your catenary measuring instrument is shown in the status bar below you will be informed about the used com port the serial number the fitted Disto and about the connection type You will be informed about the options during the measurement through the plain text display
33. re Systems 31 Version 3 0 12 1 03 31 2013 Grote Software Systems a __ _ 0 L kLLE_j jUuoUUj U UUL J J JUUUUUUULkL j Version 3 0 12 1 03 31 2013
34. request file which you will receive during the setup This license request file must be sent by e mail to the following email address grote softwa re systems ewetel net A Note Please use your default e mail program You cannot send an e mail from this setup Within 24 hours of the request for a license you get via e mail to the specified email address your corresponding license file A Note The license request can only be processed on working days Short delays are possible After receiving your license file please save this into the folder FMcaptureKey or at the corresponding location which you choose 3 1 1 First Segment License Request For implementation of the first segment insert the original data medium in the CD DVD drive and start the file Setup exe in the folder Setup FMcapture For Windows Vista Windows 7 und Windows 8 you have to consider the user account control please always implement the file Setup exe as administrator and allow the program to start explicitly If you are not the administrator and you do not possess the appropriate authority these requirements have to be ensured before the setup User Account Control E r Don t run the program unless you know where it s from or you ve used it before z 1 Setup exe Unidentified Publisher Program name Setup exe gt Cancel Publisher Unknow I don t know where this program is from or what it s for File origin Hard drive on this computer gt Al
35. rt 3 27 20132 39PM File folder _ Ound1 3 10 2013 9 37 AM Text Document 24 Ound1 3 10 2013 9 37 AM Text Document 1 6 2013 12 09PM Text Document _ Attribut 2 1 6 2013 11 48AM Text Document Attribut 3 1 6 2013 11 49 AM Text Document wert111 3 10 2013 3 49 PM Text Document wert111_1 3 10 2013 3 49PM Text Document Libraries B Documents P Music Pictures E Videos Homegroup 18 Computer Network Attribut 1 txt files txt Via the tab Attributes you can load one file for an attribute field The file is the data source for the appropriate attribute field So it is necessary to represent all the contents of this file line by line and only as text format These files have to be available in the format of text files txt 1 27 kU Version 3 0 12 1 03 31 2013 Ge Grote Software Systems With Load you can search through the browser for your desired file and upload with a double click or open it with Open You can assign all three attributes to the files independently x E Project_FMcapture Testdateien Attnbut_1 bd Description by user attribute 1 street attribute 2 devision wees re Furthermore you have the option to give each of the three attributes a specific name in this tab For this purpose just tick description by user lf you do not use this option FMcapture uses the default name object location and comment e
36. t forever and cannot be restored By Save you can save the opened file manually with all current changes The file is not closed in this case 20 LL i lt 7 AM lt lt lt r ar lt lt Version 3 0 12 1 03 31 2013 Grote Software Systems EM dan HP03C834 HP Deskjet Fe Microsoft XPS Documen ah PDF Architect lt EEE gt Status Offline Pant to file ion 1P 192 168 178 27 Host HP03C834 Page Range oa Number of copies Depending on the configuration you have the option of spending data to a printer via the button Print For this purpose click the softkey Print choose printing options click as Settings or from settings of this choice and click softkey Print again You will see the printer menu and you can still make adjustments and or execute the print one FMcapture 3 00 Data m FMcapture 3 0 With Close the open data file is closed When you have not saved manually you are prompted for it now All current changes are saved only with the button Yes 124 ll Version 3 0 12 1 03 31 2013 Grote Software Systems 4 5 Data Export The Data Export function allows you to export data to a data file in different formats Here you can export the complete data file You can use a program specific format or you can determine the individual data entries and the order itself You can export with the following formats Text file txt separator here freely sel
37. tep by Back Previous Repairing If problems with the software FMcapture should occur or the program does not work as usual you can let the software installation be repaired through Setup For implementation of the second segment insert the original data medium in the CD DVD drive and start the file Setup exe in the folder Setup FMcapture For Windows Vista Windows 7 und Windows 8 you have to consider the user account control please always implement the file Setup exe as administrator and allow the program to start explicitly If you are not the administrator and you do not possess the appropriate authority these requirements have to be ensured before the setup The setup program is started After short information you are conducted to the choice of setup options Choose Repair and start the repairing with Next Version 3 0 12 1 03 31 2013 Grote Software Systems You can close the setup with Exit after successful reparation The program can be used as usual now If nevertheless problems should arise contact the support 3 3 Uninstall O nly use the setup of FMcapture for uninstall An uninstall of your system can only be assured in this way For implementation of the second segment insert the original data medium in the CD DVD drive and start the file Setup exe in the folder Setup FMcapture For Windows Vista Windows 7 und Windows 8 you have to consider the user account control please always implement the fil
38. ware Systems As a next step choose the archive location for the license request file and click Next The license request file is created and deposed in the previous chosen memory path Close now the first segment with Exit S y A LL Version 3 0 12 1 03 31 2013 Ge Grote Software Systems li This program might not have installed correctly If this program didn t install correctly try reinstalling using settings that are compatible with this version of Windows Program Setup exe Publisher Unknow Location Hard drive on this computer Reinstall using recommended settings This program installed correctly What settings are applied If you get this message after the finish of the setup please confirm by The program is not installed correctly You can always interrupt the setup in the first segment with cancel You always get back to the previous step by back previous Please send the license request file via email after the finish of the first segment to the following email address grote software systems ewetel net AN Advice Please use your standard email program for that You cannot send the email from the setup 3 1 2 Second Segment Program Installation For the implementation of the second segment insert the original data medium in the CD DVD drive and start the file Setup exe in the folder Setup FMcapture also see 3 1 1 For Windows Vista Windows 7 und Windows 8 you have to consi

Download Pdf Manuals

image

Related Search

Related Contents

  Samsung SyncMaster U70  Sennheiser 830 S Headphones User Manual  warning  

Copyright © All rights reserved.
Failed to retrieve file