1. eeo ep pe ei ene LJ d DDUHDDHDHHUHHHUHDODDD DU gt GRAPKHTEG i ci gt USB I F terminal amp e E Power switch left side I Right side gt c D lt a gt midi LOGGER GL220 I SN Control panel keys AC adapter jack USB device terminal GND terminal T DC LINE INPUT OUTPUT G USB MEMORY a5 a5 amr a9 893 85 GR GR BGP ofa e 5V OUT LG X i X m ras Te Ix m a A Power output connector for humidity sensor Analog input terminal Humidity sensor is the option B 530 External input output terminals LOGIC PULSE e EXT TRIG SAMPLE e ALARM Logic alarm cable When using the B 513 option Label f D C Ime eo Vg yy V V Label Battery cover One battery pack can be installed Stands Battery pack is the option B517 Before using the stands read the precautions provided in Section 1 3 Operating Environment
2. 3 20 e The specifications etc in this manual are subject to change without notice GL220 UM 151 April 1 2010 1st edition 01 GRAPHTEC CORPORATION ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de GRAPHTEC CORPORATION 503 10 Shinano cho Totsuka ku Yokohama 244 8503 Japan Tel 81 045 825 6250 Fax 81 045 825 6396 Email info 9 graphteccorp com Web www graphteccorp com Printed in Japan ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de
3. Dual View Replaying 1 Free Running When in Free Running status you primarily set up the system to capture data You can check the current input signal as a waveform or digital values Operations available during Free Running Measuement parameters settings The MENU key is used to change various setting items in configuration menus SPAN TRACE POSITION The SPAN TRACE POSITION key is used to change settings Display mode The DISPLAY key is used to change the display mode File operations The FILE key is used to perform file related operations Data replay The REVIEW key is used to replay captured data The TIME DIV key is used to change the time axis ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp 17 CHAPTER 3 Settings and Measurement 2 Capturing Capture time Time of Capturing Note is displayed when the capture time is long kar faer Ala omc Re ey PN Fri Als c 2 oons SU H k LI Capture file name During data capture data is captured into the Internal memory or USB device You cannot use the MENU key to change the setting Operations available during capture SPAN TRACE POSITION The SPAN TRACE POSITION key is used to change settings Display mode The DISPLAY key is used to change the display mode Displaymode Dual View replay The REVIEW key is used to
4. CHAPTER 2 Checks and Preparation Wiring Cable tips are bare tips Perform wiring for the necessary functions Channel Number Logic Pulse output Wire Color Orange with red dotted line Orange with black dotted line Gray with red dotted line Gray with black dotted line White with red dotted line White with black dotted line Yellow with red dotted line Yellow with black dotted line Trigger input external sampling input Pink with red dotted line GND Pink with black dotted line Shielded Logic and pulse are switchable Alarm output Orange with red dotted line 1 Orange with black dotted line 2 Logic Pulee input Grey with red dotted line 08 Grey with black dotted line A White with red dotted line White with black dotted line 2 Alarm output Yellow with red dotted line id Yellow with black dotted line 4 Pink with red dotted line Trigger input sampling input Pink with black dotted line GND Shielded ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de 9 CHAPTER 2 Checks and Preparation 2 7 Attaching USB Memory Attaching USB memory to the GL220 allows you store measured data directly AN CAUTION Adequate precautions against static electricity must be taken when handling USB memory Inserting a USB Memory Attach the USB memory to the USB memory port USB Memory NCAUTION When you attac
5. CHAPTER 2 Checks and Preparation This chapter explains how to check the GL220 s external casing and accessories and how to prepare the GL220 for operation 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12 2 13 Checking the Outer Casing Checking the Accessories GL220 Nomenclature and Functions Connecting the Power Cable and Turning on the Power Connecting the Signal Input Cables Connecting the External I O Cable Attaching USB Memory Connecting to a PC Using the Battery Pack the B 517 Option Connecting the Humidity Sensor Option Precautions to Observe When Performing Measurement Noise Countermeasures Setting the Date and Time ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 2 Checks and Preparation 2 1 Checking the Outer Casing After unpacking check the GL220 s outer casing before use In particular please check for the following e Surface scratches e Other flaws such as stains or dirt 2 2 Checking the Accessories After unpacking check that the following standard accessories are included Standard Accessories CD ROM Optional Accessories Item Option number Remarks Shunt resistor 250 Q B 551 250 O Rated power of 1 W Maximum service voltage of 15 8 V Built to order 0 32 1 0 x 1 6 x 5000 mm 0 32 1 0 x 1 6 x 5000 mm TC200 TD1000 5 per set par
6. CHAPTER 3 Settings and Measurement Logic and Pulse settings Makes settings related to digital input lt For Pulse gt lt For Logic gt II TT a TAR 2240 2 6e TIUCEI en eee gi Dicplsy omlag Jets oer Li B males c PRO nbige E d 1L Fus 89 els E REIS T saln n SC ey om 1 6 Logic Pulse Selects the processing method for digital input 1 7 Input Sets the pulse measurement mode This setting is available only if Pulse is selected in 1 6 Selection item Pulse input measurement is disabled Revol Counts the number of pulses per second and captures the value multiplied by 60 as rpm value Counts Captures the cumulative number of pulses for each sampling interval from the start of measurement Captures the number of pulses for each sampling interval 1 8 Filter Sets the filter for input Selection item Disables hardware filter On Enables hardware filter It is effective in a noisy environment The filter is approximately 30 Hz 3 dB 1 9 Pulse Slope Sets the slope direction to count the number of pulses This setting is available only if Pulse is selected in 1 6 Selection item Description Counts the rising edges of pulses m PEE Counts the falling edges of pulses ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d CHAPTER 3 Settings and Measurement
7. Never use a damaged power cord e Use of a damaged cord may result in a fire hazard due to electrical shock e f the cord becomes damaged order a new one to replace it Unplug the power cord from the socket ALTHEN LTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de Safety Precautions Safety Precautions m N CAUTION Do not use or store the GL220 in a location exposed to direct sunlight or the direct draft of an air conditioner or heater e Such location may impair the GL220 s performance Storage Use prohibited Do not use the GL220 in a location subject to excessive mechanical vibration or electrical noise e Such location may impair the GL220 s performance Use prohibited If fluid or foreign matters enters inside the GL220 turn off the Power switch and disconnect the power cord from the electrical socket e Use in such status may cause a fire hazard due to electrical shock or current leakage e Contact your sales representative or nearest Graphtec vendor to request repair e Unplug the power cord from the socket Do not attempt to lubricate the GL220 s mechanisms e Such action may cause the GL220 to break down No lubrication Do not place coffee cups or other receptacles containing fluid on the GL220 e Fluid spilling inside the GL220 may cause a fire hazard due to electrical shock or current leakage QA Avoi
8. esl E Hc isasel Spe Uab Nu Beis ed Cer ssh ess br gt TE i a h reen y alan al ua Lu Liz pasil l sm opu zu Setting Cursor Position Move to Position Time Selected Posi Position Position 0 to end Foston Time data tion For example if the sampling interval is 100 ms capture desti nation is the internal memory and the number of data points is 10000 settings up to 99 9 s are available Date from the start to end of the data Time Time from the start to end of the data Off On Data search CH1 to 10 Logic Pulse Alarm Logic and Pulse are displayed only if the Logic Pulse func tion is On in the AMP settings Both TH 4L Level me ue e Set numeric value i numeric value Statistical calculation Execute gt Press right key to execute between cursors 9 1 Move to First Data Executing this option moves the currently selected cursor A or B to the start of the data 9 2 Move to Last Data Executing this option moves the currently selected cursor A or B to the end of the data 9 3 Move to Center Executing this option moves the currently selected cursor A or B to the center of the data HEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 9 4 Move to Selected Position Sets a position relative position in time or time an
9. x 3 Scaling 1 000000 1000 x1 x1000 x1000000 Sets the scaling factor for a calculation result lt Example gt Result 0 001 Result 1000 x 1 0 001 x 1 1000 x 1000 1 1000 1 x 1000000 1000 1000000 0 001 Ce die upper and lower limits of values of a span in which a waveform should be dis aye The setting value is in reference to a calculation result Sets the decimal point position for a span setting Selects a unit in which a calculation result should be displayed Current length area volume speed acceleration frequency weight work pressure flow rate temperature Selects a unit to be used after conversion A unit displayed in this field belongs to the clas sification selected in Select To set a unit not displayed in this field set arbitrary text in Arbitrary unit The setting selected in this field is displayed in Arbitrary unit 8 Arbitrary Unit Sets a unit to be used after conversion Arbitrary text consisting of alphabetical characters and numerical values can be set as a unit Refer to page 3 43 for details on the text input When Select or Choose is used the setting is reflected in this field e CHECKPOINT e Calculation results are displayed in volts The calculation result for 100 mV 100 mV is 0 2 Use Scaling to display this result as 200 mV S eRLTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de
10. Bele tee ven F l yen Tit er Te Lis GL we VER ioe OD 22 O0KkITIO JTEe GL IPFI Tt I 6 1 File Operation Operate files in the main memory and USB device For details on file operation see on page 3 41 6 2 Data Save Saves data being replayed to the internal memory or USB memory lt li ie ne method is Auto gt If the naming method is Arbitrary gt Description Folder Specify a folder to which you want to save data Refer to page 3 41 File box for details File Specify a file to which you want to save data Refer to page 3 41 File box for details 3 File Type Sets the file format used to save data GBD Creating a data file in Graphtec s proprietary binary format Data tampering can be prevented CSV Creating a data file in text format Replaying on the GL220 is not available 4 Name Type Set how a data file should be named Auto Automatically supplies the file name Example 20050101 123456 UG GBD Number part File creation date The file is created on January 1 2005 12 34 56 in this example UG User number of the user capturing data UG Guest U1 User 1 U2 User 2 GBD Data format GBD Binary data CSV Text format Arbitrary Data is captured to a file with an entered file name Sequential number A file is created with an arbitrary file name that has been entered followed by a sequential number 5 Save Range Sets the range of data to be saved All Data Saves
11. CHAPTER 3 Settings and Measurement This chapter describes the setting and measurement procedures for the GL220 3 1 3 2 3 3 3 4 Window names and functions Key Operation Operation Modes Setting Menus ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 3 1 Window names and functions 4 Internal memory access display 5 USB memory access display 3 Status mark 6 Remote display 1 Simplified message display 7 Key lock display 2 TIME DIV 8 Clock display 9 AC battery status display MONITOR 19 Data capture bar CH 1 18 Upper limit scale EE STENEN 10 Digital display ad bd bd bad ad ofin ofi oe mta fe mf 17 Waveform display COMPLE 10 m 11 Quick settings FIRTA 1 16 Lower limit scale KA ALARH 1 2 3 4 15 File name display 13 Pen display 12 Alarm display 14 Time stamp 1 Simplified message display Displays the operation status of the GL220 Free Rum rg Appears in the start up status or when data is not being captured Appears while waiting for trigger generation after measurement is started dn Appears when data is being captured in the internal memory melee Appears when data is being captured in the USB memory Jade Capture stop processing or other cases when data is being written to the built in internal memory or USB memory Fini shad
12. SHEH OU S RLTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 8 Text input Related to text input operations such as annotation EU scaling unit and captured data file name input FARE Ul mmip mn OTAR 26 8 22 I ere bsp Aunt LE 14 vh Zil BGOnC TS RIES POPS T eave EM Ne E EE mal TE rears P kJES eu TAN Te ei TE Operation Operation mode Operation method Text input Upper case alphabet mode When the cursor key is moved to a Lower case alphabet mode the uppermost part operation can O Numeric mde be selected using the left right key Symbol mode After selecting an operation use the down key to move the cursor to the Delete mode desired character When selecting Text used for each operation When you bring the cursor to a operation character and press ENTER the character is entered After you finish entering characters move the cur sor to OK and then press ENTER ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d 9 CHAPTER 3 Settings and Measurement 9 Data replay menu Data See menus are displayed gt pissing the MENU key during replay Tk Fel G IE Mi Dir mue Buzibi x Huc 2s Tren T Hi u Ver Se fr mac SC e sks nk t TE 1 bc WW
13. 1 10 EU Scaling settings Converts the measured signals to other units This setting is available only if Pulse is selected in 1 7 P a Setting 1 EU Setting Sets the scaling function to ON or OFF 2 Meas Value Sets a value to be converted 3 EU Output Value Sets an output value after conversion 4 Select Selects a specific engineering unit classification The fol lowing are available Current length area volume speed acceleration fre quency weight work pressure flow rate temperature 5 Choose Selects a unit to be used after conversion A unit displayed in this field belongs to the classification selected in Select To set a unit not displayed in this field set arbitrary text in Arbitrary unit The setting selected in this field is displayed in Arbitrary unit 6 Arbitrary Unit Sets a unit to be used after conversion Arbitrary text consisting of alphabetical characters and numerical values can be set as a unit Refer to page 3 43 for details on the text input When Select or Choose is used the setting is reflected in this field yJ CHECKPOINT If a message window opens follow the instruction in the message to change the setting value e The Scaling function performs calculation using a ratio of the Meas Value and EU Output Value settings The digital display shows when the converted value cannot be processed by the GL220 Setting example 1000 800 i eh
14. ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de gt CHAPTER 2 Checks and Preparation 2 4 Connecting the Power Cable and Turning on the Power This section describes how to connect the power cable and turn on the power The connection method will vary depending on the type of power supply used Connecting to an AC Power Supply Use the AC cable and AC adapter that are provided as accessories Z CAUTION Be sure to use the AC adapter that is supplied as a standard accessory 1 Plug the AC cable into the AC adapter a ANIJ AC adapter cable 3 Using the flat blade screwdriver press against the minus button above the GND terminal while connecting the grounding cable to the GL220 Connect the other end of the cable to ground 4 Plug the AC cable into the mains power outlet 5 Press the power switch on the GL220 to the ON side to turn on the power AN CAUTION Always connect the GND terminal and refer to the safety precautions The GL220 must be grounded even when connected to other devices and sharing a common ground level 2 4 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de CHAPTER 2 Checks and Preparation
15. Dula ra Smet make 5 shat Es melc mrs ko Le calzo as tan 7 nin I1 E IEH hoy a Peels su fen 4 F xvcla USB memory SSR THEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 5 After checking that the USB memory access display turns green press the ENTER key Refer to page 3 3 for details on USB memory access V CHECKPOINT CHG and a number will be appended to the file name each time you exchange a USB memory device Example When data is captured to the file TEST GBD First USB memory device TEST GBD Second USB memory device TEST CHG1 GBD Third USB memory device TEST CHG2 GBD While ring capture is On the USB memory device cannot be exchanged NCAUTION The exchange procedure must be completed within five minutes Data will be lost after five minutes have elapsed 6 4 Specify Save Destination Screen Copy Saves data being replayed as an image file to the internal memory or USB memory If the naming method is Auto If the naming method is Arbitrary gt Setting 3 Name Type Set how a data file should be named Auto Automatically supplies the file name Example 20050101 123456_UG BMP Number part File creation date The file is created on January 1 2005 12 34 56 in this example UG User number of the user capturing data UG Guest U1 User 1 U2 Use
16. O WwW O lt TS lt 2000 C 0 1 of rdg 1 5 C Reference contact compensation accurac 0 5 C Thermocouple diameters T 0 32 others 0 65 9 Reference contact Internal External switching compensation accuracy A D converter Method A gt method Resolution 16 bit Effective resolution About 1 40 000 of the range Temperature coefficient Gain 0 01 of F S C Zero 0 02 of F S C Occurs when sampling speed is 10 20 or 50 ms Input resistance 1M OQ 5 Allowable signal source Within 300 Q resistance Maximum permissible input Between input terminals voltage Between input terminal input terminal Between input terminal GND Withstand voltage Between input terminal input terminal 1 minute at 350 Vp p Between input terminal GND 1 minute at 350 Vp p Between input terminal GND At least 50 MQ at 500 VDC At least 90 dB 50 60 Hz signal source 300 Q or less At least 48 dB with terminals shorted Filter Off 2 5 10 20 40 Filter operation is on a moving average basis The average value of the set sampling count is used If the sample interval exceeds 5 seconds the average value of data obtained in a sub sample 5 seconds is used 4 4 ALTHEN AL THEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 4 Specifications 4 2 Function Specifications Function Specifications Display sc
17. Set the password Press the lt gt and ENTER keys at the same time to display the password setting screen shown below Specify a 4 digit password Pieter MEL rner 1834 Use the lt gt V keys to select numbers Press the ENTER key to confirm the password Specifying 0000 will disable password operation In case you forgot your password please contact us to acquire the master password 2 Set the password Hold down the lt lt and PI keys together for at least two seconds 3 Cancel the key lock Hold down the lt lt and b gt keys together again for at least two seconds The password setting screen shown below will be displayed Set a password Entering an incorrect password will not cancel key lock Key lock state will be retained when power is turned off ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de CHAPTER 4 Specification This chapter describes the basic specifications forthe GL220 4 1 4 2 4 3 4 4 Standard Specifications Function Specifications Accessory Option Specifications External Dimensions ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 4 Specifications Standard Speci
18. www althen de CHAPTER 4 Specifications nput Unit Specifications Number of input channels 10 channels Input terminal type M3 screw type terminal Input method Photo MOS relay scanning system All channels isolated balanced input 10 ms 1 ch maximum Measurement ranges Voltage 20 50 100 200 500 mV 1 2 5 10 20 50 V 1 5 V F S Temperature e Thermocouples K J E T R S B N W WRe5 26 Humidity 0 to 100 voltage 0 V to 1 V scaling conversion with B 530 op tion Measurement accuracy Voltage 0 1 of F S 23 C 5 C when 30 minutes or more have Temperature elapsed after the power is Thermocouple Measurement E Measurement Accuracy Range turned on Filter ON 10 O lt TS 100 2 C e Sampling 1s 10CH 100 lt TS lt 300 0 C e GND connected R 300 lt TS lt 1600 C 0 059 of rdg SOC 8 300 lt TS lt 1760 C 0 05 of rdg 2 0 C 400 lt TS 600 3 5 C 600 lt TS lt 1820 C 0 05 of rdg 2 0 C 200 lt TS lt 100 0 05 of rdg o 100 lt TS lt 1370 C 0 0595 of rdg 1 0 C LN H S K E 200 TS lt 100 of rdg Toc T J N W Co C1 l I I t 0 100 lt TS lt 800 C 0 05 of rdg 1 0 C 200 TS lt 100 0 1 of rdg 1 Bo 100 TS lt 400 C 0 1 of rdg 0 5 C 200 TS lt 100 JC 100 lt TS 100 JC 100 TS lt 1100 C 0 05 of rdg 1 0 C O N 0 lt TS lt 1300 C 0 1 of rdg 1 0 C
19. 0 0 OO Oo geg oO gg oO OG o 8 Dimension precision Error 5 mm Unit mm ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de 9 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de Index A AC line filter unde 3 26 AC Line Frequency rrrnnnnnrnnnnnrevnnnrennnnnennnnnennnnnnen 3 35 AC Power Gupphy esee 2 4 AC battery display c cccccccccesseeeeeseeeeeeeeeeeeseeaees 3 4 ACCeSSOLIOS dee ege 2 2 4 7 A D resolution eese 2 6 4 4 ALARM CLEAR EE 3 11 Alarm display are 3 4 Alarm PO o Mee 3 29 Alarm level setting sssssss 3 29 3 30 Alarm NNN 2 7 AMP SENG v 3 16 Amplitude Setting 3 20 3 22 Analog Input circuit diagram 2 15 Analog settings is cccncnsincctiiasrastancwedscsiainneanuatameeneion 3 17 AnnotatiON ME 3 20 B Background CGolor 3 35 Backup Sell E 3 27 Base Procedures Used in Settings 3 12 Battery En le ne E 2 13 MONIN RP 2 12 Battery Pack Specifications 4 7 Bitmap file ormat 3 39 sImeUme V V 3 29 3 35 C Calculation between cursor 3 46 Captured data file na
20. 10 11 CURSOR ALARM CLEAR aaannnannnnannnnannnnannonnnnnnnnnonnnnnnrnonnnnsnnrrnnrrennrronnrnsnnrrnnrrrnnrrenrrennnrene 3 11 FEE 3 11 EN 3 13 Ce FUMING EE m 3 13 BA eet e Tm NT 3 14 TA VT FS AN e mtm 3 14 Ce A o EEE EEE A O A 3 15 T SMN cm E Emm 3 16 EMMA 4 1 4 1 Standard Ke Ee en TE 4 2 Standard SOSCHICAUONS Lasser sakene 4 2 internal memory ENE are Grense 4 3 Fn 4 3 Mo 4 3 HVIS 4 4 42 ME nee leet er e EE 4 5 Function SPECICATION 4 5 MFT ene 4 5 External Input Output Functions arrrrnnrrnnnnrrnnnrnnanernnnrnnnnnnnnnnnnnnnrnnnsennnnennanennnnennnnennnnnnnnsennnnennnnene 4 6 43 Accessory e e E ee Le CN 4 7 ENN 4 7 NNN 4 7 Battery Pack B 517 Option rannnnnnnrnnnnennnnennnnennnnennanennnnrnnanrrnansenansennarennnsennanennnnennnnennnnennanennnnssnnn 4 7 Humidity Sensor B B30O Optpont 4 7 17 PEN DIS Mr 4 9 MEL S 1 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de CHAPTER 1 General Description This chapter provides a general description of the GL220 and its features 1 1 1 2 1 3 1 4 1 5 1 6 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de Overview Features Operating Environment N
21. 13 Function Gpecitfcatons 4 5 G ec 3 32 H Humidity sensor 2 14 4 8 I Jager ed E 4 3 Information ranornnrrornnrrvnnnennnnevnnnennnnennanennnnennnnene 3 36 MI 3 17 3 21 lere M 4 4 Internal Memory access display oaren 3 3 device specifications eseseseesss 4 3 Inter CH Op setting 3 16 3 20 K ET Eoo C n 3 9 Key lock display aen 3 9 VEG E 3 7 L E 90 5 0 gt 1 4 3 35 LCD DIUSDIDBSO rore A ctae a RUE 3 34 Level operations cccceeccceeeeeseeeeseeeeeeeeeseeeeseeess 3 31 LISUOT ODIO EE 2 2 4 8 Load setting conditions sssesssse 3 40 E90 3 8 Logic and Pulse setting sess 3 21 PFIN e 3 16 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp Index Lower limit scale ccccecceececeeeceeeceseeceseseeeeeeeeees 3 5 Logic Alarm Cable rrrnnnnnrnnnnnronnnnrennnnnernnnnrennnnnennnn 2 7 Internal equivalent circuit of I O 2 8 M Ve ee 3 33 Maximum input voltage errereen 2 15 EE snina eeN 3 8 Monitor Specifications eeeeseeessseess 4 3 Move to Center 3 44 Move to First Data ENEE 3 44 Move t
22. 3 CHAPTER 3 Settings and Measurement 8 Clock display Displays the current date and time Refer to page 3 35 for details on setting the date and time 9 AC battery display Running on AC or DC power supply Running on the battery The remaining battery power is 100 to 91 Running on the battery The remaining battery power is 90 to 61 Running on the battery The remaining battery power is 60 to 3196 Running on the battery The remaining battery power is 30 to 1196 d Running on the battery The remaining battery power is 10 or below AN CAUTION Data capture automatically stops when the remaining battery power drops to 10 or below during data capture e The power is automatically turned off when the remaining battery power is 0 e fthe power has been turned off due to battery shortage inputting AC power will not turn on the power Turn off the power switch once and then turn it on again e Use the remaining battery power as a guideline because it is not accurate This indicator does not guarantee the operating time with battery 10 Digital display Displays the input value of each channel Use the SPAN TRACE POSITION keys to switch the display Use the VA key to select the channel you want to activate enlarged display The waveform of the active channel is displayed at the top Displays the input value int ELLs The span of the active channel can be changed using the lt gt keys Eun
23. CH 1 Scaling 1 gt 1 12 Misc lt For Logic gt lt For Pulse gt om MELL Poe V z MELL LES dez gr Ge Ee glaa dz TIL e ac Deen dez gr Ux Ee Ze Setting 1 Waveform Color 0 to 31 for each of red green blue RGB Setting 2 Amplitude Setting S CRLTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 2 DATA settings This menu is used to specify capture related items and calculations NAF NI GATA Te Ae 22 2 ae E TTT ER E Inta Are AE y Tills Herz 4 7 HS ZE ME OG wf ene i ae A S El Jl qu mg 1n IO Lis ke z f RUD ECHTEN krige Zeta E DT dere eed 5 3 Faldas L LHO tiet l a f culation EE EET _ MER Ca Drkeines 2 dn f Setting Selections available Sampling 10 20 50 100 125 200 250 500 ms 1 2 5 10 20 30s 1 2 5 10 20 30 min 1h Available sampling intervals vary depending on the input settings and the number of channels to be used Refer to 2 1 Sampling Interval for details Capture destination AC Line Filter Backup Off 1 2 6 12 24 hours Folder name Calc Settings 1 Off Average Max Min Peak RMS Calc Settings 2 Off Average Max Min Peak RMS Captured data file name Setting Selections available Folder File Capture destination MEM USB1 Folder Text input if the naming metho
24. Connecting to a DC Power Supply Use the optional DC drive cable B 514 N CAUTION Use a power supply within the 8 5 to 24 VDC range 26 4 VDC max 1 Configure the tip of the DC drive cable B 514 2m to enable it to be connected to the DC power supply 2 Connect the DC output side to the power supply connector on the GL220 Shielded lead side gt White side 3 Connect the DC input side to the DC power supply Z CAUTION Be sure to check the polarity of the wire tips when performing wiring 4 Press the power switch on the GL220 to the ON side to turn on the power 2 5 CHAPTER 2 Checks and Preparation 2 5 Connecting the Signal Input Cables This section describes how to connect the signal input cables Terminal Configuration and Signal Types BD I zOvLASOd mas sno Elle Le EO wie wa DBDBODDUDODDODDBSDOSOSU EN fei pee CH1 CH10 A LJ CT UJ UJ UJ UJ OO J UJ UJ UJ UJ UJ UJ UJ UJ OC ECT ww mm on meme leloek sv our M a geleeesesee d CEA Terminal configuration Voltage input Thermocouple input DC
25. Operating Environment EEE EEE sy 1 3 Ambient Operating Conditions nnneannnneannonrnneenrnrnesrrnresrrrrnsrrrrenrrnrennrnreosrnrrrstnrrrnnrensrnnrennnrennne 1 3 Warming up te 1 3 Contiguration When BI 1 3 1 4 Notes on Temperature Measurement nennen nennen nnne nnn nena nnne nre nnne enar 1 4 1 5 Notes on Using the Monitor nennen nennen nnne nnne nnne nnne nnn nnn nnne 1 4 1 6 Changing the Display Language 1 4 2 Checks and Preparation rarnnnrnanennnnnnrnanenannnnrnnnrnasennrnnnenannnnsnnnenunenusnnnene 2 1 2 1 Checking the Outer Casmg E 2 2 22 Checking the Accessories E 2 2 2 3 GL220 Nomenclature and Funchons 2 3 2 4 Connecting the Power Cable and Turning on the ower 2 4 Connecting to an AC Power Supply nennen nennen nennen nnne nena nnn nsn ann nsns 2 4 Connecting to a DC Power Gupphy 2 5 2 5 Connecting the Signal Input Cables essssssssssssssseeeeeeee nnne nnne nennen nennen nnn nnne nnns 2 6 Terminal Configuration and Signal Types nennen nnns 2 6 2 6 Logic Alarm Cable Connection and Funchons sees nnne nnns 2 7 Logie Alarmi Cape CONNEC HOM ere m T 2 7 Internal Equivalent Circuit of the Input Output Circuit rrrernnnrornnnnnonnnnnonnnnnennnnnnnnnnnnnnnnnnennnnnennnnee 2 8 MAING S 2 9 2 Attaching USB Memnon EN 2 10 Inserting a USB Memory ssssnnssssnnssrnnsrrenrrrrorrrrsrrrrrnrrsrnrrrrrrrsrrrrs
26. The position of the active channel can be changed using the lt gt keys a e The ON or OFF of the active channel display can be changed using the lt gt keys Refer to page 3 7 for details For a channel with a calculation mark as shown below calculation between channels is ON 19 TENE 0 5450 Calculation mark 11 Quick settings Displays items available for easy operation Use the VA keys to activate the Quick setting and the left right keys to change values The SAMPLE item cannot be changed during data capture 12 Alarm display Displays the alarm output terminal status The number with which an alarm has occurred is displayed in red The channel with the alarm cause has a red input value in the digital display area 13 Pen display Displays the position of each channel signal trigger and alarm range Trigger position Alarm range in Rising Falling Win ln Win Out Stop position Start position J ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 14 Time stamp Displays the time stamp of a currently displayed waveform as time PET sill Ri ET Bu Hr I This indicator shows that the measurement data was captured at 15 26 49 15 File name display 1 During data capture A capture file name is displayed during capture MEM DOE EE LEE 179622 UG BBI If the ring c
27. alarm output terminal for which an output destination number must be specified for each channel outputs an alarm Refer to page 3 30 for details on the condition setting for each channel 3 5 Alarm hold When On is selected here and once the conditions are met an alarm is not canceled even if the conditions are no longer met later Press the CURSOR key to cancel it 3 6 Send burnout alarm When On is selected here the generation of a burnout refer to page 3 35 causes the alarm output terminal to output an alarm ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp 9 CHAPTER 3 Settings and Measurement Trigger level settings Alarm level settings Specifies detailed conditions for each channel when the start and stop side source settings are Level The configuration of the level trigger is as shown in the figure below Trigger Alarm output n Combination Pulse and Logic are switchable Pulse and Logic are switchable Specify an alarm output destination for each channel and Pulse Logic Each of the alarms is ORed at the output destination Example If you specify 1 as the output destination of 1CH and 2CH and 2 as that of 3CH and 4CH Alarm Output 1 occurs when one of 1CH and 2CH meets the conditions and Alarm Output 2 occurs when one of 3Ch and 4CH meets the conditions lt Trigger level settings Alarm level setting
28. ay Measurement starts alarm generated Upper limit level 14 Lower limit level CH 1 Win Out Used to specify the upper and lower limits for each channel When the input signal level goes or is out of these limits a trigger alarm is generated Trigger alarm generation area gt Measurement starts alarm generated Upper limit level Lower limit level CH 1 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen d amp gt CHAPTER 3 Settings and Measurement Dead zones of trigger and alarm levels Trigger and alarm levels are provided with a dead zone in order to prevent false detection due to noise Since a dead zone exists as shown in the figure below the conditions are met at different points between rising and falling signals Therefore errors in relation to the setting levels are generated as shown in the figure below lt For Temperatures gt Dead zone Setting value 0 3 C Trigger alarm setting level Setting value 0 3 C Conditions met here in rising Conditions met here in falling de CHECKPOINT An alarm that has occurred is canceled at the following levels For rising setting Setting value 0 4 C For falling setting Setting value 0 4 C lt For Voltages gt Dead zone Setting value 0 5 of range For 1 V range 1 V 0 5 0 005 V Trigger alarm setting level Se
29. use the GL220 in other position than described in the above the measurement accuracy may not meet the specifications To prevent possible toppling use both of the stands of the GL220 when you place it inclined Use the GL220 with both of the two stands open as shown in the figure above ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de wwW lthen de CHAPTER 1 General Description 1 4 Notes on Temperature Measurement Please observe the following precautions when performing temperature measurement Do not block the air vents Always provide a space of at least 30 cm on all sides of the GL220 For stabilized temperature measurement allow the GL220 to warm up for at least 30 minute safter turning it on Exposure of the input terminals to direct drafts direct sunlight or abrupt changes in temperature may impair the equilibrium of the input parts and result in measurement errors To measure temperature in such an environment take appropriate countermeasures such as changing the installation site of the GL220 e f measured values fluctuate due to external noise try the countermeasures described on page 2 16 1 5 Notes on Using the Monitor The monitor is an LCD display unit and so the display will vary depending on the operating environment 7 CHECKPOINT If the screen saver function is used it will operate and clear the screen i
30. voltage LEES st RENNES E Cl SE EN A ET LER Compensation wire is used if it is required Resistance temperature detector Current input not available x DC current 1 T Ne Ej Shunt resister Ex The current is converted to the voltage in the shunt register For 4 to 20mA current input installing 250 ohms 0 1 resister for converting 1 to 5V 250 ohms shunt register is the option B551 SE High voltage terminal terminal for high voltage input signals e Low voltage terminal terminal for low voltage input signals Description Isolated input scanning 20 50 100 200 500 mV F S 1 2 5 10 20 50 V F S 1 5V K J E T R S B N W WRe 5 26 16 bit Effective resolution About 1 40 000 of the range Filter Off 2 5 10 20 40 Filter operation is on a moving average basis The average value of the set sampling count is used If the sample interval exceeds 5 seconds the average value of data ob tained in a sub sample 5 seconds is used 2 6 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 2 Checks and Preparation 2 6 Logic Alarm Cable Connection and Functions Logic Alarm Cable Connection The logic alarm cable B 513 Option enables logic pulse input external trigger input external sampling input and alarm signal output Connect the logic alarm cable B 513 Option to the external input outpu
31. 0 50 k 500 k 5 M 50 M 500 M C F S Inst mode e Function Counts the number of pulses for each sampling interval Resets the count value after each sampling interval e Spans 50 500 5000 50 k 500 k 5 M 50 M 500 M C F S Maximum number of pulse inputs Maximum input frequency 5OkHz Maximum number of count 50kC sampling 16 bit counter 4 6 aLTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 4 Specifications 4 3 Accessory Option Specifications Control Software Description Compatible operating system Windows XP Vista Windows 7 Main unit control realtime data capture data conversion data replay Main unit settings AMP settings Data Capture settings Trigger Alarm settings Report settings Other settings Captured data Realtime data CSV Binary Internal memory CSV Binary USB memory CSV Binary Display Analog waveforms logic waveforms pulse waveforms digital values Display modes Y T View Digital View Report View X Y View between Cursors only during replay The maximum minimum and current values are displayed during measurement Accessories CD ROM Battery Pack B 517 Option Capacity 7 4V 2200mAh 17Wh Running time When using the LCD display approx 5 hours When using the screensaver approx 6 hours Note When capturing to internal memory at 1 s sampling using new battery pac
32. 1 CHAPTER 3 Settings and Measurement Setting 1 Inter CH Op Settings Sets what to do in calculation between channels Four arithmetic operations x can be set as calculation between channels Refer to the next page for details Sets the upper and lower limits of values of a span in which a waveform should be dis played 3 Annotation string Sets an annotation comment to be displayed for a channel The maximum nee of Ge is 31 Alphanumeric characters kana and symbols can be input Refer to page 3 43 for details on the text input 4 Waveform Color Setting 0 to 31 for each of red green blue RGB 5 Amplitude Setting 1 to 8 dots 6 Auto Zero ADJ Performs calculation using the current input voltage as the zero position voltage value The range of voltages that can be automatically adjusted is 10 of the setting range lt Example gt For 1 range the input voltage can be adjusted between 0 1 V and 1 0 V For temperature input this function is not available 7 Reset Auto Zero ADJ Cancels the zero position voltage value and displays the input voltage 8 Zero position voltage Displays the zero position voltage value Display only Se Inter CH Op Settings 1 gt Setting 1 Inter CH Op Settings Off On If this SS is ON the channel has a calculation mark in the digital display etc 2 Operation E X Function CH Y rn X CH1 to CH10 Function Four arithmetic operation functions x
33. Appears when the GL220 waits for you to press the Start Stop key to stop it after data capture Menor Route Appears while the data in the internal memory is being replayed ieee sae Appears while the data in the USB memory is being replayed Appears when backup fails e g when the USB memory specified as the backup destination has been removed Deno Wave Mc Appears when a demo waveform is being displayed not measurement data Refer to page 3 28 for details on the data capture such as a trigger and repeat Refer to page 3 24 for details on the memory used for capture CAUTION Do not turn off the power while the simplified message is Memory Recording Recording USB mem or Writing Disk those with an asterisk above Data will become corrupt and will not be captured Operate the GL220 after checking that the status mark is STOP 9 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de CHAPTER 3 Settings and Measurement 2 Time DIV display Displays the current time scale 3 Status mark Appears when neither capture nor replay is in progress Appears when data is being captured in the internal memory or USB memory Appears when waiting for a trigger during capturing and the stop key after capturing Appears when data in the internal memory or USB memory is being replayed N CAUTION Do not turn off the
34. ES e Format disk Format the disk Details of allowed operation will depend on the operation target Moves between folders lt Move up one folder gt Move down one folder ENTER Finalize the operation QUIT Close the file box lt Setting example gt The following shows an operation example where a folder named TEST is created for captured data and automatically saved EE ear ORTA ree usem on a ER In the Data save Destination choose Select folder and bae Zell pace press the ENTER key Dano ETRE Jra et H HH ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d CHAPTER 3 Settings and Measurement ELLEN Pi ii ee Use the gt key to move to the target folder z m E naar dL ll MR F ha E HELLE E PR NE NEM ON Use the PI key to select Create new folder PCI Press the ENTER key When the input box for a new folder name opens enter TEST and click OK ds le ue A DD LTA RH Ee ee DI 8 Lin A mE tk B docu So eH RR bev Tril Ia THUS RAP CATA TES USM ot MET ER Use the lt K key to choose Select file folder Q Sehl pap be le E Sp Use the VA key to move the cursor to the created TEST EH 1881 d folder and press the ENTER key td DN Dm er DATA mee mee zem CUP gt gt EU Select OK to close the screen 4540 ell pus Se ee Ure Sl e Here Lo Uno okt inge te ee
35. HEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de 9 CHAPTER 4 Specifications External Input Output Functions Input output types e Trigger input 1 ch or External sampling input 1 ch Logic input 4 ch or Pulse input 4 ch e Alarm output 4 ch Switch between Logic and Pulse Switch between Trigger and External sampling The logic alarm cable B 513 option is required to use the external I O func tion Input specifications Input voltage range 0 to 24V single ended ground input Input signal No voltage contact a contact b contact NO NC Open collector Voltage input Input threshold voltage Approx 2 5 V Hysteresis Approx 0 5 V 42 5 to 3 V Refer to page 2 8 for details on the input circuit Alarm output specifications Output format Open collector output 5 V pull up resistance 10 KQ Maximum ratings of output transistor Collector GND voltage 30 V Collector current 0 5 A e Collector dissipation 0 2 W Refer to page 2 8 for details on the output circuit Pulse input Revolutions mode engines etc e Function Counts the number of pulses per second enables them to be con verted to rpms e Spans 50 500 5000 50 k 500 k 5 M 50 M 500 M PRM F S Counts mode electric meters etc e Function Displays a count of the number of pulses for each sampling interval from the start of measurement e Spans 50 500 500
36. Input signal measurement is disabled No waveform or digital value is displayed Used for measuring direct current voltage Used for measuring temperature Humidity Used for measuring humidity with the humidity sensor B 530 In this case the voltage range will become 1 V and the EU settings will not be available 1 2 Range Selects the range of measurement Voltage 20 50 100 200 500 mV 1 2 5 10 20 50 1 5 V TC K TC J TC T TC R TC E TC B TC S TC N TC W Humidity No selection available Available SPAN Settings Voltage Ranges SPAN Resolution 5 500 to 5 500V 0 050V 0 001V ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp CHAPTER 3 Settings and Measurement Temperature Ranges Range Maximum SPAN Minimum SPAN dir Minimum Resolution Range 270 to 2000 C 200 to 1370 C 270 to 2000 C 200 to 1100 C 270 to 2000 C 200 to 400 C 0 1 C W Humidity Range Range Maximum SPAN Minimum SPAN Minimum p p Hesolution p Oto 11096 1 3 Filter Filter processing Filter processing performed on the GL220 is the moving average shown in the following figure n 5 If the filter setting is 5 D n 4 n 3 n 1 n 5 yJ CHECKPOINT If the sample interval exceeds 5 seconds the average value of data obtained in a sub sa
37. L220 is not available 5 Ring Capture Sets the ring capture function to On or Off 6 Number of Ring Specifies the number of data points in one file when the ring capture function is On Capture Points See the following figure for details 7 Ring Capture Displays the possible measurement time with one file when the ring capture func Time tion is On Jf HEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement Ring Capture Function Ring captur has been operating in this instrument is as follows Hit Start capturing data Captured data is saved into the File 1 When the specified number of datas are saved into the File 1 the captured data is saved into the File 2 The number of data is specified in the Ring Capture Points menu When the specified number of datas are saved into the File 2 the captured data is saved into the File 3 The File1 is deleted at this point When the specified number of datas are saved into the File 3 the captured data is saved into the File 4 The File2 is deleted at this point When the specified number of datas are saved into the File 4 the captured data is saved into the File 5 The File3 is deleted at this point Repeat this action Stop capturing data File1 File2 File3 File4 File5 JG N 1 1 l n I I N s When capturing is stopped at t
38. MB and the amount of memory remaining is about 160 MB As time elapses during data capture the amount of used memory increases and the amount of remaining memory decreases The remaining time for data capture shows a length of time during which data capture is available with the amount of remaining memory If the amount of remaining memory is more than 2 GB however this part shows remaining time during which data capture is available with one 2 GB file Remaining time more than 99999 hours is displayed as ri 2 During data replay Displays the display position cursor position and trigger position graphically Cursor A position Cursor B position Name of file being replayed Capture data size m Range for which a waveform is currently displayed S CnaLTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 3 2 Key Operation This section describes key operation 2 TIME DIV 1 SPAN TRACE POSITION 4 QUIT 3 MENU 5 Direction Keys 6 ENTER 7 FAST FORWARD key KEY LOCK 11 CURSOR ALARM CLEAR 8 START STOP USB DRIVE 12 FILE 10 DISPLAY 9 REVIEW 1 SPAN TRACE POSION Switches the display in the digital display Used to change the settings related to waveform display during Free Running when stopped data capture and data replay Pressing this key
39. PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER 5220 USER S MANUAL MANUAL NO GL220 UM 151 GRAPHTEC ALTHEN RENE o MESS UND SENSORTECHNIK SINCE 1978 Introduction Introduction Thank you for purchasing the GL220 midi LOGGER Please read this manual thoroughly before attempting to use your new product to ensure that you use it correctly and to its full potential Notes on Use Be sure to read all of the following notes before attempting to use the GL220 midi LOGGER 1 Note on the CE Marking The GL220A complies with the EN61326 Class A standard based on the EMC directive 89 336 EEC It also conforms to the EN61010 1 standard based on the LV directive 72 23 EEC Although the GL220 complies with the above mentioned standards be sure to use it correctly in accordance with the instructions and notes provided in its User s Manual Moreover use of the GL220 by incorrect procedures may result in damage to the GL220 or may invalidate its safeguards Please confirm all of its notes regarding use and other related information to ensure correct use Warning This is a Class A product according to the EMC directive In a domestic environment this product may cause radio interference or may be affected by radio interference to the extent that proper measurement cannot be performed Notes for Safe Operation 1 Be sure to use the Graphtec s
40. RMS Number of operations maximum of 2 can be set simultaneously Calculation method Realtime calculation and calculation between cursors during replay Realtime calculation results are displayed in the Digital Calculation Display Screen Search functions Function Search the captured data for the required number of points Search type Channel Pulse Logic Level Alarm search Annotation input function Function A comment can be input for each channel Inputtable characters Alphanumerics Number of characters 31 Displayed up to 18 characters in the Waveform Digital screen or 14 characters in the Digital Calculation Display screen Trigger Functions tem Repeat Trigger Off On Trigger types Start Data capture starts when a trigger is generated Stop Data capture stops when a trigger is generated Trigger conditions Start Off Level Alarm External Time Date Weekly Stop Off Level Alarm External Time Date Weekly Level trigger judgment modes Combination Level OR Level AND Edge OH Edge AND Analog channel judgment mode H 1 L 4 Window In Window Out Logic channel judgment mode H 1 L J Pulse channel judgment mode H 1 L 4 Window In Window Out Alarm judgment modes Detection method Level Edg Analog channel judgment mode H T L 4 Logic channel judgment mode H T LW Pulse channel judgment mode H T L V e Window In Window Out Window In Window Out ALT
41. all data regardless of the cursors Data between Cursors Saves only a range of data between cursors A and B ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d gt CHAPTER 3 Settings and Measurement 6 3 Remove Exchange USB Memory The GL220 allows you to exchange the USB memory while data is captured to it Exchange the USB memory in accordance with the following procedure 1 Press the FILE key to open the FILE menu i abel Feo 2 0 22 3 en PAL TUR AI 1 ku E Deen EN po rn pt Em ed FL 2 Up LTH staili c Uwe EE D gu H MM Ly Lat d rb H in H OI H HU ZE Fanar E do lala WC d A os LU 4 Liesute D LIE Bl Hatlem reak kbolnast ns E M MTM abil Feo 2 0 22 3 en PAL 19 jl 1 rur Det Dee py pt peike Ven Boe UE co EE FL E Tp LTH staili c Uwe EE D gu H ui DEI H ab LI E syte gt H Ir amp Eur drndkscuE pf LLE ratl 52d 7an anebt kbolnast ni mE 1O l K 3 You can remove the USB memory device when the message is displayed Bin t rake shat Fs melc oc Le calzo as tan 7 nin I1 E IEH hoy c a Peels su fen 4 F xvcla USB memory NCAUTION Do not remove the USB memory device before the message is displayed Data may become corrupt and inaccessible 4 Insert a new USB memory device IE ger ep sta Lz rori zcl gcd
42. ampling speed of 10 ms 1ch by setting fewer channels for measurement sampling speed is 100 ms and above for temperature measurements e The new ring memory capture function maintains latest data even after capturing for a long term You need to set how long you want to keep data Data Control amp Processing e The application software provided lets you set conditions and monitor data on on a computer using the USB interface e The application software allows you to control multiple GL220 units from a single computer to easily perform multi channel measurements e The USB drive mode function enables the GL220 s internal memory to be recognized as an external drive by your PC Connect the GL220 to your PC and turn on the power supply to the GL220 while holding down the START key Captured data can be read from the application software to files and displayed for processing e Data can be transferred off line to a computer using USB memory ALTHEN ATHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de CHAPTER 1 General Description 1 3 Operating Environment This section explains the operating environment for the GL220 Ambient Operating Conditions 1 Ambient temperature and humidity the GL220 must be operated within the following ranges Temperature range 0 to 45 C 0 to 40 C when battery pack is mounted Humidity range 5 to 85 RH 2 Environm
43. apture setting is ON a file name displayed during capture ends with RINGx x represents a number but the actual file name does not include RINGx In the above figure if the ring capture is set to ON the file name during capture will be displayed for example as lt MEM gt 091225 091225 130620_UG_RING4 GBD but the actually created file will be lt MEM gt 091225 091225 130620_UG GBD Refer to page 3 25 for details on the ring capture setting 2 During data replay Information on the time axis of the cursor is displayed during replay Time difference between Cursors A and B Time to which the cursor points Selected cursor 16 Lower limit scale Displays the lower limit scale of the currently active channel 17 Waveform display Displays the waveform of the input signal 18 Upper limit scale Displays the upper limit scale of the currently active channel ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen d P S CHAPTER 3 Settings and Measurement 19 Data capture bar 1 During data capture Displays the elapsed time and the memory usage status Elapsed time Remaining time for data capture Amount of memory used Amount of memory remaining Total amount of memory If for example 256 MB USB memory is inserted and about 96 MB is used before data capture the total amount of memory is 256 MB the amount of memory used is about 96
44. ated power supply range for the adapter is 100 to 240 VAC and the rated frequency is 50 60 Hz Do not use any other voltages e Maximum input voltage If a voltage exceeding the specified value is input the semiconductor relay in the input section will be damaged Never input a voltage exceeding the specified value even for a moment Between terminals A gt e Maximum input voltage 60Vp p ere O aaa Between input terminal input terminal B gt e Maximum input voltage 60Vp p e Withstand voltage 350 Vp p at 1 minute lt Between input terminal GND C gt e Maximum input voltage 60Vp p e Withstand voltage 350 Vp p at 1 minute LU GRAPHTEG E i EEID cM 1 L WSU Le Geen J 509 ve i 50 nup uei Channel Switching Relay NCAUTION Capacitors have been incorporated into the input circuit to increase the noise elimination capability After voltage measurement when the inputs have been disconnected there will still be some electric charge remaining Before starting another measurement operation short circuit the and terminals to enable self discharge The GL220 has a scan system While in the status open in which signals are not input to the input terminal measured results may be influenced by signals from other channels In such a case turn OFF the input setting or sh
45. available 2 6 Statistical calculation setting Two types of operation can be performed on all channels This section explains setting what to do in statistical calculation Setting Calculation is not performed Average Displays the simple average value of the data during Max Displays the maximum value of the data during data capture i Displays the minimum value of the data during data capture Displays the RMS value of the data during data cap ture The calculation formula is as follows R M S J XD n D data n number of data y CHECKPOINT e Calculation results are displayed in the Digital Statistical Calculation Display screen Use the dd bb keys to set All Mode Refer to page 3 9 for details on All Mode At power on calculation is started The result is cleared when you press the QUIT key or the Start key to start measurement ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d CHAPTER 3 Settings and Measurement 3 TRIG settings This menu is used to specify trigger conditions and alarms Fs Amni mr nun ri HEH HTHH cae oe a LI IT uM ee Loe eee WW ite m E le eee A gt Dest s oc 188998 veo tld ACHT sseeemesd ofl aD DER 7 me Hx M cg REM UW X d Iz Ion ex Start Side Source Setting Level Analog Off TH 4L Window In Window Out Logic Off TH VL Pulse Off TH 4L Window In Window Out L
46. cted in this field is displayed in Arbitrary unit 7 Arbitrary Unit Sets a unit to be used after conversion Arbitrary text consisting of alphabetical characters and numerical values can be set as a unit Refer to page 3 46 for de tails on the text input When Select or Choose is used the setting is reflected in this field 8 Reads the current Substitutes the current measurement value into 2 Measurement value and 3 temperature measurement EU output value value The value is not substituted when burnout occurs or the scale is exceeded I lI La or W CHECKPOINT If a message window opens follow the instruction in the message to change the setting value e The Scaling function performs calculation using a ratio of the Meas Value and EU Output Value settings The digital display shows when the converted value cannot be processed by the GL220 e The span may be changed depending on the Scaling settings Fortemperature input the offset setting for an input value is used Setting example For voltage input Upper limit 5 000 20 00 Lower limit 5 000 20 00 Setting example For temperature input EU Output Value 22 0 C 25 0 C 3 C is always added to the measurement value XX XX rpm 20 00 rpm rs ch CH 1 Scaling 1 gt A ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp
47. d is Auto File Text input if the naming method is Arbitrary or Sequential number Name Type Auto Arbitrary Sequential number File Type Binary GBD Text CSV 2 1 Sampling interval Sets the sampling interval for data capture The table below shows the number of measuring channels and sampling interval values that can be set If data fluctuate due to noise set the sampling interval to a value which enables the digital filter function Number of Measuring Channels 1 Allowed Sampling Interval Sampling Interval which enables Digital Filter 10 ms or slower 2 20 ms or slower 2 125 ms or slower 3 CH to 5 CH 50 ms or slower 2 250 ms or slower 6 CH to 10 CH 100 ms or slower 500 ms or slower 1 Number of Measuring Channels is the number of channels in which input settings are NOT set to OFF 2 The temperature setting is not available for sampling intervals of 10 20 and 50 ms 7 CHECKPOINT To use the digital filter function you must set the AC power supply frequency accurately Follow the instructions on page 3 35 to ensure that the settings are accurate ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp lt 2 CHAPTER 3 Settings and Measurement 2 2 Captured data file name Select the name of a file or folder to which you want to save capture data If the naming method is Auto If the naming method is Arbitrary gt
48. d moves the currently selected cursor A or B to this position or time f the Method is Position f the Method is Time m ERIT Hess co ze ozto Pci ha lara T t Wan Hat E 114 A Hs en Cd ra r el TI ENEE brul list ee ee e UE Bare l Setting Selections available 1 Fi 1 Method Sets the method for specifying the position to move the cursor to Select Position or Time 2 Position Sets the position to move the cursor to Specify how far down you want to move the cursor from the capture start position assumed as 0 Only positions down to the end of the data can be set Check the setting range in the A part 3 Time Sets the position to move the cursor to using a date and time Only positions from the start to the end of the data can be set Check the setting range in the B part 9 5 Cursor Sync l en lst ds R Sets up the function that moves two cursors in synchronization Selection item Cursors are not synchronized Only the specified one cursor moves Two cursors move in synchronization Cursor A is always the fulcrum Cursor Synch is turned Off when you move a cursor using Move to Selected Position or perform Data Search 9 6 Date Search Sets the search conditions to be used in the next sections 9 7 Find Next and 9 8 Find Previous The operation is Edge operation Selection item Sets the channel to be used for search CH1 10 The spec
49. d water Watch out electrical shock q 3 ER To insert or disconnect the power cord or signal input cable grasp the power cord s plug or the signal input cable s connector e Pulling the cord cable itself damages the cord cable resulting in a fire hazard or electrical shock Q No pulling Do not input voltage that exceeds the permissible input voltage range that is specified on the GL220 s label e Exceeding the specified voltage input range may cause electrical shock or a fire hazard Use prohibited Never clean the GL220 using a volatile solvent such as thinner or benzine e Such action may impair the GL220 s performance e Clean off any soiled areas using a soft dry cloth No volatile solvents ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www dIthen de CONTENTS CONTENTS BUT ORTON c H E NOE ON USE q About Registered Me ET 1 To Ensure Safe and Correct Use reren renen i Conventions Used in This Manual nennen nennen nnn nennen nnns nna nnn nsn nnn nnn i Description of Safety Symbols cccccccseesccccseeeeeeceeeeeeeeseeeeeeceeeeeeeessaueeeeseaeeeessaaeeeessaueeeesaaneeesssaaeeees i ere US e e a NENNT ne E E E I TT i 1 General Descriptio sarrien araa tias boe a tt FERES V CES duca E 1 1 ES WE EEE EE NE EN 1 2 FOT ee 1 2 1 3
50. e name Sequential number A file is created with an arbitrary file name that has been entered followed by a sequential number 6 7 Load Loads and reflects the GL220 setting conditions from a file real pg 1g Eee EH TE Sam Ter es ud Setting 1 File Specify a file to which you want to save data Refer to page 3 41 File box for details SAR THEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 7 File box The file box used to set captured data files using the DATA menu or for disk operations accessed using the FILE menu is operated as follows lt File box by disk operations gt b ck Jpcratic GU DY hee Sota caer ts E mW P eoe miy ETES aae props os AKTE ub in Change the operation of the file box Show properties Display details of a file or folder Select file folder Select files or folders to write data Create new folder Create a new folder Create new file Create a new file Hename Change the file or folder name Copy file folder Copy files or folders Select file to copy delete Select the file to copy or delete Select copy destination and copy Select the copy destination and copy Delete file folder Delete files or folders Change file sort order Change the order in which files are displayed View setting Change displaying information for files L3
51. ed acceleration frequency weight work pressure flow rate temperature Choose The selections vary depending on the unit selected in the above Arbitrary unit Text input Misc Waveform color O to 31 for each of red green blue RGB setting Amplitude Setting 1 to 8 dots ST run ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de Q O 5 CHAPTER 3 Settings and Measurement Switching displays Analog and logic pulse can be switched as shown below T ULT TERRE NR AA ZEN s in E Je LHP OTT TRA TARE III e VC Be E Je Lat zu Lee ulze 34s f Ulap su Pu vez Lela 7 e Lane d RE eai T Pack ut Lu i no Tey N p H 2 AT Eu E ari re E Ji EW i D A en E a a ee ree eel E ana apen p pU Display Logic Pulse Data i 4 Display Analog Data Analog settings Specify the conditions for analog signals de CHECKPOINT When you use CH ALL to set an input range and filter all channels are set to the same values if the input is the same Range is set only for the same input channels However the range of a channel is not changed if its EU scaling is set to On Span All Settings is set only for the same range channels If CH1 has an input that is set to Off the input of CH ALL is set to Off 1 1 Input Selects input condition Selection item Description
52. eeded eDo not permit small children to touch the GL220 e The following describes important points for safe operation Please be sure to observe them strictly Conventions Used in This Manual To promote safe and accurate use of the GL220 as well as to prevent human injury and property damage safety precautions provided in this manual are ranked into the five categories described below Be sure you understand the difference between each of the categories This category provides information that if ignored is highly likely to cause fatal or serious injury to the operator This category provides information that if ignored is likely to cause fatal or serious injury to the operator This category provides information that if ignored could cause physical damage to the GL220 pny g amp This category provides information that if ignored is likely AN HIGH to cause burns or other injury to the operator due to contact TEMPERATURE Jury H with high temperature ELECTRICAL This category provides information that if ignored is likely to SHOCK expose the operator to electrical shock Description of Safety Symbols The A symbol indicates information that requires careful attention which includes warnings The point requiring attention is described by an illustration or text within or next to the A symbol The symbol indicates action that is prohibited Such prohibited action is described by an illustration or text with
53. efon 49 0 6195 70060 e info althen de www althen de CHAPTER 2 Checks and Preparation 2 13 Setting the Date and Time If you are using the GL220 for the first time charge the internal rechargeable battery and then make thedate and time settings CAUTION If the GL220 is not used for a period of approximately six months the internal rechargeable battery may be discharged and the date and time may revert to the initial settings If this happens recharge the battery before using the GL220 How to Recharge the Rechargeable Battery Using the AC adapter provided connect the GL220 to a mains power outlet turn on the power switch and then leave the GL220 connected for at least 24 hours How to Set the Date and Time Press the MENU key display the OTHR screen and then set the date and time at the Date Time Settings sub menu For details see Date Time on page 3 35 AAF DATA TRIG UBER THA HE LYD krinstressi Screen Lavard P ausr om Earum Lu ect fwe ina I E LL E sta Tims aLL 22 G2 107008 ET TL WTETE Era ist LS BE dagar cera th ban local raat Lk scent oar E imo MES alae mm rar Eug ae Er 1 DH H s T TET RET Dec forme ALTHEN LTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de
54. ent do not use in the following locations A Location such as being exposed to direct sunlight Locations exposed to salty air corrosive gases or organic solvents e Dusty locations e Locations subject to vibration or impact Locations subject to voltage surge or electromagnetic interference such as lightning or electric furnaces 3 Installation category overvoltage category e The GL220 belongs to Installation Category ll defined in IEC60664 1 Never use the GL220 for Installation Category III or IV 4 Measurement category e The GL220 belongs to Measurement Category defined in IEC61010 1 e The GL220 cannot be used for Measurement Category Il Ill or IV 7 CHECKPOINT If condensation occurs Condensation occurs in the form of water droplets on the device surfaces and interior when the GL220 is moved from a cold to a warm location Using the GL220 with condensation will cause malfunctioning Wait until the condensation has disappeared before turning on the power Warming up Before Use The GL220 should be allowed to warm up with the power turned on for approximately 30 minutes to ensure that it operates according to the specified performance Configuration When in Use It is recommended to use the GL220 while it is laid flat or inclined on the stands Usage Configuration Laid flat Inclined on the stands Opening the stands Z CAUTION To prevent possible malfunction do not block the air vents of the GL220 If you
55. enu configuration To return to the MONITOR window when the SPAN TRACE POSITION window is displayed To cancel remote status in which keys are disabled through interface control To close the menu screen To quit data replay This key is primarily used for the following operations To move a menu or setting item during menu configuration To move the cursor during replay To move the active channel in the Waveform Digital and Digital Calculation Display screens VA keys To change the setting of SPAN TRACE POSITION lt gt keys e To change the Quick setting lt keys e To change the channel to be displayed in the Digital Calculation Display screen lt keys This key is primarily used for the following operations To finalize setting items during menu configuration or open submenus ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de CHAPTER 3 Settings and Measurement 7 FAST FORWARD key KEY LOCK This key is primarily used for the following operations To move the cursor at high speed during replay To change the operation mode in the file box To set key lock Hold down the left right FAST FORWARD key for at least two seconds press again to unlock A password for canceling the key lock can be specified See page 3 47 for details To change the display mode in the Digital Calculation Dis
56. eric value EU output Upper limit Set numeric value value Lower limit Set numeric value Dec pt EU output upper limit x 1 x 10 x 100 x 1000 Select Current length area volume speed acceleration frequency weight rK D j ure The selections vary depending on the unit selected in the above Text input Choose Arbitrary unit Inter CH Function Op Settings Operation Scaling O Qed SICH A gt j o o o x lt c gt D F 22 x m D T 3 D m 1000000 1000 x1 x1000 x1000000 Upper Lower limit Set numeric value Dec pt x1 x10 x100 x1000 x 10000 Select Current length area volume speed acceleration frequency weight work pressure flow rate temperature Choose The selections vary depending on the unit selected in the above Arbitrary unit Text input Upper limit Set numeric value tings Lower limit Set numeric value Annotation string Text input Max 31 characters Waveform color setting 0 to 31 for each of red green blue RGB Amplitude Setting 1 to 8 dots Perform Auto Zero ADJ gt Press right key to execute Reset Auto Zero ADJ gt Press right key to execute Logic Pulse Off Logic Pulse Logic Filter Misc Waveform color O to 31 for each of red green blue RGB setting Pulse Input ff Revolution counts Counts Inst Filter ff On Slope H VL EU Function ff On Meas Value Set numeric value EU output value Set numeric value Select Current length area volume spe
57. evel OR Level AND Edge OR Edge AND Level Set numeric value Alarm Alarm port 1 0203 4 number Date From 2005 1 1 to 2035 12 31 From 0 0 0 to 23 59 59 Weekly Off or On setting for each of Sunday through Saturda From 0 0 0 to 23 59 59 From 0 0 01023 59 59 0 0 O From 0 0 1 to 9999 59 59 Stop Side Source Setting Off Level Alarm External Input Time Day Duration Analog Off TH JL Window In Window Out Logic Off TH VL Pulse Off TH VL Window In Window Out Level OR Level AND Edge OR Edge AND Set numeric value Alarm Alarm port 1 0203 4 number Date From 2005 1 1 to 2035 12 31 From 0 0 0 to 23 59 59 Weekly Off or On setting for each of Sunday through Saturda From 0 0 0 to 23 59 59 Alarm Level Analog Off TH 4L Window In Window Out Settings Logic Off i ve Pulse off 1 L Window In Window Out 3 1 Start side source setting Specifies trigger conditions to start data capture Selection item Description Starts capturing data unconditionally when you press the Start Stop key Level Starts capturing data when a specified level is reached When Level is selected the condition for each channel must be set Refer to page 3 31 for details Starts capturing data when an alarm is generated in the specified alarm port External Input Starts capturing data when an input signal is received from an external trigger terminal A trigger is established at a transition from 5 V open to 0 V sh
58. f no operations are performed during the preset time If the screen saver operates press any key to restore the display Z CAUTION e Condensation may form on the LCD screen if the GL220 is moved from a cold to a warm location If this occurs wait until the LCD screen warms up to room temperature e The LCD screen is manufactured to extremely high precision Black dots may appear or red blue and green dots may not disappear Likewise streaks may appear when viewed from certain angles These phenomena are due to the LCD screen construction and are not signs of a fault 1 6 Changing the Display Language You can choose either English Japanese French German Chinese or Korean as the language displayed on the screen The default display language is set to English when the GL220 is shipped overseas To change the display language see the instructions in OTHR Language ARP TDATATTRIG USER OTHR H E Goreer CW Power on Gerti G T EST Lo ur NE LEB LL T HP Caste Time M qo NETTE umm Ler t Li OI Disk e E ak Pa es FAE Ee Eru isti LS E agar ccs th Raa Vri rat A doe ee Met Dama uzvz em ae cree lelpr OLCK EA AE wel ALTHEN ACTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de
59. fications Standard Specifications Description Number of analog channel 10 channels External input output Trigger input or external sampling pulse logic input 4 channels or pulse input 4 channels alarm output 4 channels PC interface USB Full speed standard Internal memory device Approx 2 GB internal memory USB memory slot Full speed supported standard Data backup functions Setup conditions EEPROM Clock Lithium battery Clock accuracy 0 002 approx 50 seconds per month ambient temperature 23 C Operating environment 0 to 45 C 5 to 85 RH 0 to 40 C when operated in batteries 15 to 35 C when battery is charging Withstand voltage Between each input channel and GND 1 minute at 350 Vp p Between each input channels 1 minute at 350 Vp p Power supply AC adapter 100 to 240 VAC 50 60 Hz DC input 8 5 to 24 VDC max 26 4 V Battery pack option 7 4 VDC 2200 mAh Power consumption AC power consumption when the supplied AC adapter is used No Condition Normal During recharging consumption batter 1 When the LCD is ON 12VA 29VA When the screensaver is operating 11VA 28VA DC power consumption DC Condition Normal During recharging voltage consumption batter When the LCD is ON 0 18A 0 6VA When the screensaver is 0 15A 0 57VA operating 12V When the LCD is ON 0 31A Recharging battery Is not possible 12V When the screensaver is 0 26A Recharging operating battery Is not possible 5 8 5V When
60. g made directly from the DC power supply instead of the AC adapter the DC voltage must be at least 16V The operating temperature range during charge is from 15 to 35 C ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d 19 CHAPTER 2 Checks and Preparation 2 10 Connecting the Humidity Sensor Option Connect the and lead wires of the humidity sensor the B 530 option to the desired terminals and theninsert the round connector into the 5V OUT connector on the GL220 Brown Connected to the terminal a C White Connected to the terminal Humidity sensor the B 530 Option Connected to the 5V OUT terminal NCAUTION Do not use the sensor in a strong electrolyte envronment Measured results may not satisfy to the stated 2 lATHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 06195 70060 info althen de www althen de CHAPTER 2 Checks and Preparation 2 11 Precautions to Observe When Performing Measurement Please be sure to read the following carefully in order to prevent electric shocks or shorts DANGER Do not apply voltage of 60Vp p or above between the analog input section and main unit or between analog input channels e Do not apply high voltage high frequency signals 50 kHz and above Be sure to use only the AC adapter provided as a standard accessory The r
61. g replay e Drun I PRS or ure RI 0 el ee bt Ws d TTE d MELET WEI AELIAN m WEI SI EI TH SI AN T DR EE n WI m pe ki SL Ps WM Lh L L E m RF TH H H n n r H LEI 1 r n YLHIILTI LL 1 YLHIILTI LL LL 4 HE LUE THE Temi LI Ira HILHEI Wikre LI lra LL TN E UTE MILL Ae et Wat man MUU UE WO VH A oy S E FHEFIIT 1E LK T sr de o a EE E E FALLE 1E LK T sr s A i cursor B cursor A i cursor A cursor B The selected cursor turns white and the other one turns gray e When the alarm setting is Hold generated Alarm the maintained alarm is cleared Free Feral 7 0 Cer e Lar de Eee li Xu ITE a e 2 rs E fe Eat mic na Ve ag 73 EE EE EE SE ENEE EE ER 2 24 HEEN EET SEE AE I las le nc TET M Alarm generated channels Et ai et Br s l1 J LJ L WEIZ 1 Fr og og Fr og I L Alarm output terminal status Black Alarm is not issued Red Alarm is issued 12 FILE Performs file related operations This key is use for operations related to the Internal memory and USB device copy and delete Copies the window e Saves all data or data between cursor A and cursor B during replay can be set during replay only e Saves or reads the currently set condition into the USB device can be set during Free Running only e Exchanges USB memory during data capture can be set only while data is captured to USB memory ALTHEN ALTHEN GmbH Fra
62. h the USB memory to GL220A be careful during handling so as not to bump or drop the unit Supported USB Memory Specifications Power supply 5 V e Power consumption 250 mA or below e Capacity no limit each file must be smaller than 2 GB USB memory with security functions such as fingerprint authentication or having a connector without a shell metallic part cannot be used Use the B 550 option as USB memory 2 1QiTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de CHAPTER 2 Checks and Preparation 2 8 Connecting to a PC Use the USB cable to connect the GL220 to a PC Connection Using a USB Cable Use the USB cable to connect the GL220 to a PC USB cable 7 CHECKPOINT If the USB cable is used the USB driver must be installed in your PC Please refer to USB Driver Installation Manual in the accessory CD ROM for the installation procedure Use the A B USB cable to connect the GL220 to a PC A connector B connector l CO ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen d CHAPTER 2 Checks and Preparation 2 9 Using the Battery Pack the B 517 Option e The B 517 battery is the only battery type that can be used with the GL220 e Refer to the specifications P 4 7 for information on the battery run time e The ope
63. he STOP poinf in the above the File4 and the File 5 are remained These files are consolidated into one file and it is saved Then the ring catpuer is completed File4 Filed Filexx Saved ef de CHECKPOINT Twice as many files as the Number of Ring Capture Points will be created at the maximum CAUTION When you save files create a folder and then save the files in the folder Regardless of the remaining capacity if you try to save files in the root directory you may not be able to save files due to file system restrictions de CHECKPOINT Changing the sampling interval capture destination number of measuring channels number of channels for which the input is not Off etc will change the Free Space and Capture Time on the screen If you find that the measurement time exceeds the Capture Time take one of the following measures e Change the sampling interval Copy the files on the internal memory to your PC and delete them e Change the capture destination to USB memory with larger free space DIE 1 IN LI r 4 Free Space Displays the amount of memory space available for capture at the capture destination Capture Time Displays time available for capture The Capture Time is calculated for 2 GB at the maximum The Capture Time more than 366 days is displayed as More Than 366 days ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de w
64. ified analog channel is used for search Logic1 4 The specified logic channel is used for search Pulse1 4 The specified pulse channel is used for search Alarm1 4 The specified alarm output is used for search Sets the search mode Both Detects an edge at which alarm output changes from genera tion to cancellation or vice versa when Alarm is selected TH Detects a rising edge of an analog signal or an edge at which alarm output changes from cancellation to generation VL Detects a falling edge of an analog signal or an edge at which alarm output changes from generation to cancellation Level Sets a voltage level to be searched for when the search channel is an analog or pulse channel 9 7 Find Next Executing this option moves the cursor to a next position where the search conditions are met down from the current cursor position Specify the search conditions as described in 9 6 Data Search 9 8 Find Previous Executing this option moves the cursor to a previous position where the search conditions are met up from the current cursor position Specify the search conditions as described in 9 6 Data Search ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp 9 CHAPTER 3 Settings and Measurement 9 9 Execute Calculation Executes calculation between cursors Executing this option opens a window to display calculatio
65. igger is not assumed to be generated even if the trigger conditions are met when the START key is pressed A trigger is assumed to be generated when the trigger conditions after not being met are met again A trigger is still assumed to be generated even if the trigger conditions are met once in the Edge operation and then are no longer met Example Rising Example Rising Edge And for 1CH and 2CH If the START key i dh ee If the START key is pressed here S ey IS pressed here Cer 1CH a trigger is assumed to gger g od be generated here too An edge exceeding the setting levelis pH lll lll Werft O required is generated here Measrement is started here Measurement is P Measurement is immediately started from here in started in the the Edge operation Level operation Trigger and Alarm operations Rising Atrigger alarm is generated when the input signal is higher than the specified level Trigger alarm generation area ager d Measurement starts alarm generated Setting level CH 1 Falling A trigger alarm is generated when the input signal is lower than the specified level Trigger alarm generation area gger d gt Measurement starts alarm generated Setting level Win In Used to specify the upper and lower limits for each channel When the input signal level comes or is between these limits a trigger alarm is generated Trigger alarm generation area
66. in or next to the Q symbol O The symbol indicates action that must be performed Such imperative action is described by an illustration or text within or next to the symbol ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www Althen de Safety Precautions Safety Precautions N WARNING Be sure to securely connect the GL220 s power cord e After checking that the Power switch is turned off connect the power cord s female plug to the GL220 and then connect its male plug into the electrical socket Use of the GL220 without the power cord securely plugged into the electrical socket may result in electrical shock due to current leakage Before running the GL220 using a DC power supply be sure to ground the protective ground terminal to avoid electrical shock and fire hazards For grounding use a ground wire with a diameter of at least 0 75 mm2 When using the GL220 in an environment where grounding is not possible ensure that the voltage to be measured is no greater than 50 V DC or rms Securely connect the power cord Make sure that the socket has a good protective ground Before turning on the GL220 ensure that the electric socket s supply voltage conforms to the GL220 s power rating e Use of a different supply voltage mav cause damaae to the GL220 or a fire hazard due to electrical shock or current leakage Use of a differentsup
67. ks at 25 C environment Note The running time depends on such as the operating environment the amount of charge left in the battery and connecting USB memory Battery type Lithium secondary battery Charging method Mount in the main unit or use a separate battery charger Time required for charging Main unit approx 4 hours Switchover in the case of a Because the battery is used together with the AC adapter the power supply power failure will be switched automatically to the battery in the event of a power failure Note The AC adapter is the primary power source Operation environment Running on battery 0 to 40 C Battery being charged 15 to 35 C Other functions When the battery is running low measured data is saved and the file is clised automatically during internal memory and USB memory capture The remaining battery power is displayed ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 4 Specifications Humidity Sensor B 530 Option Item Description Allowable temperature range 25 to 80 C Allowable humidity range 0 to 100 RH Relative humidity measurement 3 RH 5 to 98 RH at 25 C accuracy Method Capacitance method Relative humidity measurement Measurement environment Measurement accurac accuracy 0 10 C 5 RH EEN 10 20 C 4 RH 20 30 C 3 RH 30 40 C 4 RH 40 50 C 5 RH Sensor output Sensor po
68. me 3 23 3 24 OT og Vo E 3 14 3 15 Clock display area rrnnnrnnnnnrnrnnnvrnrnnnvnvnnnrnnnnnnennnnn 3 4 Gonnechngtoabt 2 11 Connection Diagramm 2 6 Control Software sees 4 7 CURSOR key eege Gegend gees 3 11 Cursor Position MEE 3 44 ET 3 45 D Data Capture bar 3 6 Data replay men 3 44 REG 3 37 DATA SN TEE 3 23 Data RT ei DEE 3 44 3 45 Data and NE 3 35 luae EE SEE 2 17 DC Power Supply ccccccsccccseeecseeceseeeeeeeseeeeeees 2 5 Dead zones of trigger and alarm levels 3 32 Demo Waveform Mode rrrnnnnnrnnnnnnnnnnnnennnnnennnnnnnn 3 36 Department name 3 33 Digital Display areg 3 4 Direction keys uk 3 8 DISPLAY ROY asset eti qp ME nemici 3 10 Dual View Replaying 3 13 3 14 E Safe Nae iom 3 31 ENTER KOY o m 3 8 EU 3 19 3 22 Execute Calculation ccccseseeeseeeeseeeeeeeeeeeens 3 46 External Dimensions eese eee 4 9 External Input Output Functions Specifications 4 6 External ul e ele E 3 26 F FAST FORWARD key esee 3 9 BS OK qe 3 41 SEE 3 11 miliaria a 3 37 File name display area sssssessessse 3 5 FIE OVET AON MEE 3 37 ml RR TE UU 2 6 3 18 3 21 FAN c a 3 45 Find Previous eeeeeeeee eere 3 45 FCS AUN Gl T 3
69. mple 5 seconds is used ST run ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de CHAPTER 3 Settings and Measurement 1 4 EU Scaling settings Converts the measured signals to other units lt For voltage input gt lt For temperature input gt esr alist d ye ne LG Gu are ALT r lined tho cette horor aare U ral E REPE Setting 1 EU Function Sets the scaling function to ON or OFF 2 Meas Value Upper Sets the upper and lower limits of values to be converted Lower For temperature input there is no distinction between upper and lower limits See the setting examples shown below for details 3 EU Output Value Up Sets the upper lower limit output values after conversion per Lower For temperature input there is no distinction between upper and lower limits See the setting examples shown below for details 4 Dec pt Sets the decimal point position for an EU output value 5b Select Selects a specific engineering unit classification The following are available Current length area volume speed acceleration frequency weight work pres sure flow rate temperature 6 Choose Selects a unit to be used after conversion A unit displayed in this field belongs to the classification selected in Select To set a unit not displayed in this field set arbitrary text in Arbitrary unit The setting sele
70. n results For description of the calculation results see the table below Pressing the FILE key opens a window for saving Statistical calculation results Specify a save destination and select OK to save statistical calculation results in text CSV format A save destination and a file name can be specified in the same way as for specifying a file for captured data Refer to 7 File Box page 3 41 Jal ulz 1 n alt Seg Ba oo n oli ME Tulk A i alls UM Bae aane EET E Says SEbTEITELIT sl ss ks El Es Ee wrt T oz art FIF f syr ted LH Fars an Displays the peak value of the data during data capture ax in RMS Displays the RMS value of the data during data capture The calcula tion formula is as follows R M S X 2D n D data n number of data SAR THEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 10 Quick settings 4 31 1 EECH GC ee ural n UK LUE E AE AE Ab 4 idk F kK L r r Lk ks rur onae cr oa Waveform Free Running ENN Replaying SERCH lt I gt key can be used to perform search lt Searches past side gt Searches future side 11 To cancel key lock by password A password can be set to GL220 to cancel the key lock No password is set at factory default lt Operation flow gt 1
71. ngs and Measurement 4 Replaying Ozu LEDET Displays the voltage at a point indicated by Cursor A or B or the selected cursor 4 1 H 1 H 10 TH IR 1 H roro ek I kue dest SH nius MY UHHH taste MP Nie Displays the measurement time at a point MEME indicated by Cursor A or B or the selected cursor Displays the captured data Operations available during replaying SPAN TRACE POSITION The SPAN TRACE POSITION key is used to change settings calculation d The lt or XIX gt gt keys are used to move the cursors File operations The FILE key is used to save either all data or the data between the cursors The TIME DIV key is used to change the time axis ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp gt CHAPTER 3 Settings and Measurement 3 4 Setting Menus When you press the MENU key during Free Running the following menu screens appear The menu screens are classified by the tab for each setting item rap fet om d me i usen je ome 1 1 AMP settings This menu is used to specify input signal related settings Analog settings Logic Pulse settings TT ip TEN o s MEL i Setting Input Voltage Temperature TC K TC J TC T TC R TC E TC B TC S TC N TC W Filter EU Function Scaling Meas Upper limit Set numeric value settings Value Lower limit Set num
72. nkfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp CHAPTER 3 Settings and Measurement Basic Procedures Used in Settings The following are basic operation procedures for settings 1 Press the MENU key to open each menu 2 Use the VA lt I gt key to move the cursor to the items you want to set 3 Press the ENTER key to display a list of setting values 4 Use the VA lt Ib key to select a setting value 5 Press the ENTER key to confirm the value The above explanation shows the basic procedure that may be used for each setting Please follow the procedure indicated by each menu S TALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 3 3 Operation Modes You can check the system operation status in the simplified message display simplified message display Start up status or data is not being captured Capturing Data is being captured in the main memory Memory Recording or USB memory USB Memory Recording Dual View Replaying The current waveform display and data on Memory Recording capturing is being replayed USB Memory Recording Replaying Captured data is being replayed Memory Review USB Memory Review Operation status transition START STOP key REVIEW key Capturing Replaying START STOP key QUIT key REVIEW key QUIT key
73. nresrrrrnnrrnsrrrrnnrrnreonnrrnnrennnnrnne 2 10 29 Connecingto E 2 11 Connection Using a UGbCGable eene nennen nnn nnne nnne nenas na sns nnns 2 11 2 9 Using the Battery Pack the B 517 Option 2 12 Mounting the Battery PFECKk RE IO T ET TET Om 2 12 Charging the B TEN m n 2 13 2 10 Connecting the Humidity Sensor Option seeessssesssssessssseseeese nennen nnne nnne nnn nnns 2 14 2 11 Precautions to Observe When Performing Measurement 2 15 2 12 Noise Countermeasures nenne enn enn nna nnns nane nnne n nise nni se nn rsen rris rines nnns nnns nnns 2 16 2 13 Setting the Date and TIME EE 2 17 How to Recharge the Rechargeable DBatten 2 17 How to Set the Date and Time rrrnnnnrnnnnnrvrvnnnvrnnnnrnnvnnsvnvannrnnnnnrnnnnnssnnnnnsnnnnnsnnnnsennnnnennnnnsnnnnssennnn 2 17 3 Settings and Measurement nennen nennen nnns 3 1 3 1 Window names and funchons nennen nennen nnne nnne nnne nn sna sn se irri sa nsns sina rna nns 3 2 FVN 3 7 AE PAINT RAC EP SON ease 3 7 2 TME RE 3 8 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de CONTENTS IT RW 3 8 CARRIERS ON c EN ee ee ee ee ee eee ee 3 8 EDEN 3 8 GENER erect 3 8 7 FAST FORWARD key KEY LOChK 3 9 8 START STOP USB Drive Mode 3 9 PEPE 3 10 10 DISPLAY M O 3
74. o Last Data a nnnennnennneenennenrenerer erneer enr rren 3 44 Move to Selected Position 3 45 N Noise Countermmeasures n 2 16 O Operating Environment 1 3 OTHR setting nnnaennnneennnnnennnnnennennennnesrrnresererennne 3 34 P PC Interface Specification 4 3 S ll 3 4 PIC TORI AT RR PNE 3 39 Power On Start eese nennen 3 34 Q Quick settings ooannnnneannnneannonennnnnennnesennnenn 3 4 3 47 GUIT KOY ceestis 3 8 R KANO cis haste mente 3 17 Remote display area enne 3 3 Repeated capturing ENEE 3 29 Heplaying eee 3 13 3 15 Resistance temperature detector 2 6 Return to default setting 3 36 REVIEW Ne 3 10 Ring capture Setting 3 25 Room Temp Compensation 3 35 S Sampling Internal 3 23 Save setting Conditions 3 40 Scaling settings seeeeeseeseessss 3 19 3 22 leiden M 3 39 Screen Gaver ea EE EE 3 34 Setting Menus essnrnnrnnnnnnnrnnnnnnnvnnnnnnnvvnnnnnnvnnnnne 3 16 Simplified message display area 3 2 TE ee eee 3 21 wr m 3 16 3 20 SPAN POSITION TRACE key eee 3 7 Specify Save Desimaton 3 39 Standard Gpechfcatons 4 2 Sta
75. one lire Title are MOS CAUT IL CBE x TETJE sestinab enb Erara reg Capacity 130 5 Males t Sarplaice Uri AC Linc Fi ter DRA ODE Shortest interval DLG Tevics Gack Tetting tance ns ala sel To qr ab TE OTT Dala lari de Setala TF Ax Uu s 2 MT The shortest interval is as shown in the following table Number of Measuring Shortest interval Channels 1 Digital filter OFF Digital filter ON 3 to 5 CH 6 to 10 CH 1 The Number of Measuring Channels is the number of channels for which the input setting is not OFF Jf HEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 2 5 Backup setting The GL220 has a function that periodically backs up captured data See the figure below This section explains how to set the data backup conditions as Fag Fa as Fa la LIT d GRAPHTEG d P E gt WS __ lt gt USB memory Measurement input E fem ii LOGGER GL220 B Internal memory iw Automatic backup to USB memory mud Setting Backup interval Sets the backup interval for captured data Off 1 2 6 12 24 hours Save folder Sets the folder for saving a backup file This must be a folder on USB memory or an FTP server Example GRAPHTEC 20091205 7 CHECKPOINT If ring capture is On the backup function is not
76. ort circuit If signals are input correctly measured results are not influenced by other channels ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d 9 CHAPTER 2 Checks and Preparation 2 12 Noise Countermeasures e Be sure to connect the chassis GND of the object to be measured Ensure that the chassis GND wire of the measurement object is connected to a good ground Measurement object Thermocouple e Connect the signal chassis GND and the measurement device chassis ground Use a short thick lead to connect the chassis GND of the measurement object to the GL220 schassis GND It will be even more effective if the ground potentials are the same Measurement device chassis GL220 3 x GND GND 7 CHECKPOINT Noise countermeasures If measured values fluctuate due to extraneous noise conduct the following countermeasures Results may differ according to noise type Ex 1 Connect the GL220 s GND to ground Ex 2 Connect GL220 s GND to measurement object s GND Ex 3 In the AMP settings menu set filter to any setting other than OFF Ex 4 Operate GL220 with batteries Option B 517 Ex 5 Set the sampling interval which enables GL220 s digital filter In the OTHR menu set the frequency of the AC line used Refer to page 3 35 for details 2 1 RUTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Tel
77. orted to the ground A falling edge operation occurs Starts capturing data when specified date and time arrives Weekly Starts capturing data at the specified time on days of week for which On is set Example On is set for Mon Tue Wed Thu and Fri Off is set for Sun and Sat and 9 00 is set as the time Starts capturing data at 9 00 on weekdays Does not start capturing data on Sat and Sun Starts capturing data when a specified length of time elapses S THEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 3 2 Stop side source setting Specifies trigger conditions to stop data capture Selection item Stops capturing data unconditionally when you press the Start Stop key Level Stops capturing data when a specified level is reached gt When Level is selected the condition for each channel must be set Refer to page 3 30 for details Stops capturing data when an alarm is generated in the specified alarm port External Input Stops capturing data when an input signal is received from an external trigger terminal A trigger is established at a transition from 5 V open to 0 V shorted to the ground A falling edge operation occurs Stops capturing data when specified date and time arrives Stops capturing data at the specified time on days of week for which On is set Example On is set fo
78. otes on Temperature Measurement Notes on Using the Monitor Changing the Display Language CHAPTER 1 General Description 1 1 Overview The GL220 with color monitor and internal memory are compact lightweight data loggers GL220 are equipped with an Internal memory to enable the direct capture of a large volume of data to USB memory Furthermore the data loggers can be connected to a PC via USB to enable on line settings measurement and data capture 1 2 Features Adoption of an M3 screw type terminal facilitates wiring e The GL220 enables settings to be made using dedicated keys and interactive menus using just one hand e With the GL220 s high resolution 4 3 inch wide TFT color liquid crystal display you can confirm the waveforms of measured data and each channel s settings at a glance Data Capture A large volume of measured data can be saved to a USB memory The high capacity internal memory enables measurement for a long term without the use of USB memory e The USB memory device can be removed and replaced without terminating data capture operations This allows any part of the data to be extracted during long capture operations Internal memory used for the built in memory maintains captured data even after the power is turned off The Internal memory can be used with disk images thus multiple data items can be maintained For voltage and humidity measurements data can be captured up to a s
79. play screen 4ch Mode 10ch Mode All Mode 8 START STOP USB Drive Mode This key performs the following two operations Starts stops capture e During Free Running starts capture e During capture stops capture USB Drive Mode Operation Procedure In USB Drive Mode the internal memory is recognized by the PC as an external storage media Since the internal memory is recognized as a removal disk this mode facilitates file manipulation such as transfer and deletion 1 Use a USB cable to connect the GL220 and a PC 2 While pressing the GL220 START STOP key turn the power ON 3 The external storage media is recognized by the PC and data exchange becomes possible In USB Drive Mode the display on the GL220 becomes as follows USB Drive Mode N CAUTION To exit USB Drive Mode turn off and on the power again e n USB Drive Mode no operation including data capture and data replay is available e To use USB Drive Mode a USB driver must be installed in your PC A USB driver and the USB driver installation manual are stored on the supplied CD ROM Install the USB driver according to this manual The drive letter D used in the manual location D USB Driver English GL USB UM152 PDF should be read as that of a drive on which the CD ROM is mounted The drive letter depends on your PC ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de
80. ply voltageprohibited Avoid using the GL220 in extremely dusty or humid places e Such use may cause a fire hazard due to electrical shock or current leakage Q A Use prohibited Watch out for electrical shock Prevent dust or metallic matter from adhering to the power supply connector e Adhesion of foreign matter may cause a fire hazard due to electrical shock or current leakage Q A No foreign matter Watch out forelectrical shock If the GL220 generates smoke is too hot emits a strange odor or otherwise functions abnormally turn off its power and unplug its power cord from the electrical socket e Use of the GL220 in such status may result in a fire hazard or electrical shock After checking that smoke is no longer being generated contact your sales representative or nearest Graphtec vendor to request repair Never try to perform repair yourself Repair work by inexperienced personnel is extremely dangerous Q Amateur repairprohibited Never disassemble or remodel the GL220 Such action may cause a fire hazard due to electric shock or current leakage Contact with a high voltage component inside the GL220 may cause electric shock If repair is required contact your sales representative or nearest Graphtec vendor Q No disassembly Avoid using the GL220 in places where it may be exposed to water such as bathrooms locations exposed to wind and rain and so on Watch out electrical shock Avoid water
81. power or remove the USB memory while the status mark is other than STOP those with an asterisk in the above Data may become corrupt and inaccessible Operate the GL220 after checking that the display is STOP 4 Internal memory access display The internal memory is not accessed The internal memory is being accessed Z CAUTION Do not turn off the power of the GL220 while the internal memory is being accessed Data may become corrupt and inaccessible 5 USB memory access display E No USB memory is inserted E USB memory is inserted but is not accessed E USB memory is being accessed Do not remove the USB memory NCAUTION Do not remove the USB memory or turn off the power of the GL220 while the USB memory is being accessed Data may become corrupt and inaccessible 6 Remote display CH Indicates local mode Operations can be conducted on the GL220 CH Indicates remote mode With some exceptions operations must be conducted on a PC When you cancel the connection on the application GL220_820APS the GL220 is automatically sent back to local mode If local mode is not entered press the QUIT key 7 Key lock display Eon Not in key lock status Normal operations are enabled Key lock status All the keys are locked Refer to page 3 47 for details on the key lock ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d 3
82. r 2 BMP Data format BMP Bitmap file format PNG Ping format Arbitrary Data is captured to a file with an entered file name Sequential number A file is created with an arbitrary file name that has been entered followed by a sequential number 4 File Type Sets the file format used to save data BMP Saves data in bitmap file format PNG Saves data in ping format 6 5 Execute Screen Copy Executes screen copy and saves it to an image file Refer to page 6 4 Specify Save Destination for details on specifying the save destination ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp gt CHAPTER 3 Settings and Measurement 6 6 Save Saves the setting conditions of the GL220 If the naming method is Auto If the naming method is Arbitrary gt l Ile ders KE ES ES AR hen lup Lea CK I i page 3 41 File box for details Specify a file to which you want to save data Refer to page 3 41 File box for details 3 Name Type Set how a data file should be named Auto Automatically supplies the file name Example 20050101 123456 UG CND Number part File creation date The file is created on January 1 2005 12 34 56 in this example UG User number of the user capturing data UG Guest U1 User 1 U2 User 2 CND Data format GL220 setting file format Arbitrary Data is captured to a file with an entered fil
83. r Mon Tue Wed Thu and Fri Off is set for Sun and Sat and 17 00 is set as the time Starts capturing data at 17 00 on weekdays Stops capturing data when a specified length of time elapses 4 CHECKPOINT e When External Input is used as the trigger source no stop trigger is accepted for 50 ms after capture is started e When the start trigger is External Input data is captured at sampling intervals fixed to 5 seconds if they are more than 5 seconds and retained temporarily This retained data is refreshed at sampling intervals fixed to 5 seconds if they are more than 5 seconds Since the external trigger input operation conducts detection at 10 ms intervals asynchronously from sampling the retained data becomes the first point when an external trigger is detected Starting from this point data is captured at sampling intervals e If the stop trigger is also an external trigger detection is conducted at 10 ms intervals and data capture stops as soon as the stop trigger is detected 3 8 Repeated capturing Sets up the repeat function to conduct repeated capturing Selection item Of The repeat function is disabled The repeat function is enabled After one capture is ended the next capture is started If the start side source setting is not Off the GL220 waits for a trigger 3 4 Alarm level settings Sets alarm generation conditions output destination etc When the conditions specified here are met the
84. rating temperature range of the GL220 with a battery pack mounted is as follows Running on battery O to 40 C Battery being charged 15 to 35 C Mounting the Battery Pack 1 While lightly pushing the grip of the battery cover slid the cover in the direction indicated bythe arrow 3 Attach the battery cover 2 12i7HEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 06195 70060 info althen de www althen de CHAPTER 2 Checks and Preparation Charging the Battery Expected time required for charging Approx 4 hours The battery pack is charged by mounting it in the GL220 attaching AC adapter to the GL220 1 Mount the battery pack in the GL220 see the previous section for the mounting procedure 2 Turn on the power to the GL220 Please see Section 2 4 Connecting the Power Cable and Turning on the Power 3 The CHARGE LED lights CHARGE LED 7 CHECKPOINT e The GL220 is equipped with a temperature monitor function which starts automatic charging as soon as it is cooled down Therefore depending on the internal temperature charging may not be performed immediately When charging is attempted while the power is ON charging may not be performed immediately even if the temperature environment conforms to the specification In such a case set the Screen Saver settings to ON or perform charging while the power is OFF e f input is bein
85. reen Waveform Digital screen All Waveform screen Digital Calculation Display screen Expanded digital screen Can be switched using the dedicated key toggle operation For the Expanded Digital screen the number of channels and the display channel must be specified Sampling interval 10 20 50 100 125 200 250 500 ms 1 2 5 10 20 30 s 1 2 5 10 20 30 min 1 h External 50 ms and below can be selected according to input settings and number of measured channels Waveform expansion Time axis 1 2 5 10 20 30 sec Div contraction 1 2 5 10 20 30 min Div 1 2 5 10 12 24 h Div Voltage axis variable span Scaling function 4 points can be set for each channel e The temperature range scaling function is available Functions during capture e Double screen display Exchange of USB memory e Saving of data between cursors Data save functions Capture to internal memory Capture to USB memory The setup data can be saved Main or USB memory Copy of data screen can be saved Main or USB memor Ring capture Function ON OFF Number of recording points 1000 to 2000000 When ring capture is ON the memory space that can be used for capture is one third of the free space or less Calculation between Channels Calculation type Addition subtraction multiplication and division Input target Analog channels 1 through Statistical calculation Types of operation Average value peak value maximum value minimum value
86. replay captured data in two windows at the same time save data to a device Setingcheck Time axis change o o o Setting check The MENU key is used to change the settings Time axis change The TIME DIV key is used to change the time axis 3 Dual View Replaying Bom FT Displays the voltage at a point indicated by Cursor A or B or the selected cursor a EE C AM li a Lu t ien Po Pa ALI ue H Displays the measurement time at a point indicated by Cursor A or B or the selected cursor You can replay data during capture Waveform on the right side is the current captured data and the left side is previously captureddata You can use the Direction keys lt gt to move the cursor to captured data to check digital values Operations available during dual view replaying Moving cursor The CURSOR key is used to switch between cursors A and B The lt I gt or lt lt gt gt keys are used to move the cursors Save to device The FILE menu is used to save data to a device During capture data up to the present or data between cursors can be saved to a separate file While capture to the internal memory is in progress use this feature to save data to USB memory without stopping Screen copy The FILE menu is used to copy the screen S TATHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Setti
87. ro file T e E LE ZI LRSL ast eere JC eet AR M PENH PEFR Gi AHA 224 fe d l dr ee MER Fo Liz Hers IF s Panel Ge D zeut Fre KA SER 9E ar ee le Sat H WRC d 4 Vi Macro description example file name xxx GMA ll GLF ODD CR bes ll si Te Les feet Tee bh PF SSSR Fj IP BLAA Pig Fee eee nannan F mam em rag Lal RG UTT ELD L Las lisa ETATE AE DRG CRp PC gas TESE ite DD br Phar PRS Te E r Cuil im ham my un Berrin I HHL IST Led cH LI ip A9 Apu Ee Vri dod 1AMEITHL pt Tree iF D MENSA SZ isp te fect Ire L hira Tier AS d f ling hee NCAUTION Hefer to the Interface Command Table for details on commands supported by GL220 on a separatesheet The Interface Command Table is included in the CD Library folder GL220 820 IF Command PDF Supported commands are limited to those relative to GL220 settings Read in commands cannot be used ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp gt gt CHAPTER 3 Settings and Measurement 5 OTHR settings Other miscellaneous settings are made here Up d ET SEP Se ce Le bh ro See smali re Xs ir MI aun ub Cin hg ZI vd H Gei TERI DS 1 linc gru ko so sit cotki P IF ZFETTIMESP G Lara pue ora TM uw DIER l Tempera ture setting Burn Out Date Time Date Time From 2005 1 1 to 2035 12 31 F
88. rom 0 0 0 to 23 59 59 Language Japanese English US English UK French German Chinese Korean Return to default settings gt Press right key to execute V Down button to display information Demo Waveform Mode Off On 5 1 LCD brightness Sets the brightness of the LCD backlight 5 2 Screen Saver Automatically turns off the display if the GL220 is not operated within a specified interval Turns off the display if not operated for some time to extend the service life of the LCD screen If the GL220 runs on a battery pack B 517 option the use of this function prolongs the drive time 5 3 Power On Start Sets the feature which initiates measurement as soon as the GL220 isturned on Selection item Disables the Power On Start function Enables the Power On Start function S SATHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 5 4 Background Color Sets the background colors of the waveform display area and the digital display area 5 5 AC Line Frequency Select the frequency of the AC line used Selection item For an area with a power supply frequency of 50 Hz For an area with a power supply frequency of 60Hz AN CAUTION In this setting select a frequency for noise removal using the digital filter Note that no noise in the power supply can be removed if this setting is w
89. rong The digital filter is enabled at sampling intervals of 500 ms and above 5 6 USB ID Sets the USB ID number of the GL220 Specify a number from O to 9 To control more than one GL220 unit with one PC assign a unique USB ID to each of them 5 7 Temperature setting CLP Din Den cnp Trees HE Ih a 1 Burn r Dn LE PE Selection item 1 Room Temp Compensation This parameter enables room temperature compensation settings when thermo couples are used Internal The GL220 s room temperature compensation settings are used usu ally you use this parameter External Select this parameter when measuring compensation other than that of the GL220 2 Temp Unit Toggles the temperature unit between C Centigrade and F Fahrenheit for temperature settings When F Fahrenheit is selected calculation is performed using the following formula F Fahrenheit C Centigrade x 1 8 32 Calculate the accuracy as Centigrade accuracy x 1 8 3 Burn Out This parameter enables or disables a function that conducts burnout check on a thermocouple On Periodical burnout check is conducted Off Burnout check is disabled Z CAUTION During a burnout check voltage is applied to the GL220 Therefore set Burn Out to Off when the GL220 is connected in parallel with other devices to avoid any effect from these voltages 5 8 Date Time Makes settings related to the GL220 clock 5 9 Language This parame
90. rt side source Setting 3 28 START STOP Key Leste peu inne 3 9 Statistical calculation setting 3 27 S ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de Status mark area nennen 3 3 Stop side source Setting 3 29 T TEMP VI m 3 35 Temperature seitmg reee 3 35 E Nep Pm 3 43 TIME DIV display are 3 3 TIME DIV K l undere 3 8 Thermocouple rrannnnnnennnonnnnnnnnnnnnnnnnnnnnnennnennnennnnnnn 2 6 TRIG SEWING De 3 28 Trigger and Alarm operations 3 31 Trigger Functions Gpecifcatons seeeeseeeeeena 4 5 Trigger level settings ssneesnseneneenreneree rrenen 3 30 TIME Stamp WE 3 5 To cancel key lock by password 3 47 U Upper limit scale n0annnannnannannnnnnoannnennnnnnnnnnnnnnnnnn 3 5 USB Connechon 2 11 USB Drive Mode kA 3 9 JSB ID M 3 35 USB Memory e ln e mr 2 10 access display area eene 3 3 Hemoveitvchange 3 38 EE E 3 32 USER settings 3 32 W Warming UP sesse aa E 1 3 Waveform color setting 3 20 3 22 Waveform display area rrnnnrvvnnnnrrvernnnvrrerrnnnnrennnn 3 5 Window names and functions 3 2 Z Zero Adjustment E 3 20 Zero position voltage value
91. rts stops capturing data when all of the specified trigger conditions are met Each condition is Edge operation Detection Level Each condition is Level operation method MSN For Alarm Edge Each condition is Edge operation 2 Mode Sets a trigger comparison mode for each channel Off Disables triggers for the setting channel TH rising A trigger is generated when the input signal exceeds the specified level VL falling A trigger is generated when the input signal falls below the specified level Win In Used to specify the upper and lower limits for each channel When the input signal level is or comes between these limits a trigger is generated This setting is not available for Logic CH Win Out Used to specify the upper and lower limits for each channel When the input signal level is or goes out of these limits a trigger is generated 3 This setting is not available for Logic CH 3 Level Sets a trigger comparison level If the mode is TH rising or JL falling set one comparison level If the mode is Win In or Win Out set two comparison levels Zanen ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www alen de CHAPTER 3 Settings and Measurement Level and Edge operations In the Level operation a trigger is assumed to be generated if the trigger conditions are met when the START key is pressed In the Edge operation a tr
92. s Fa Pa T Lu MD 528 d is i Te TEEETTITEISUETTTCUEUDTTNEEREIEFENE T 1 3 riu Tali e penses spe Tali s CERO Uc L 2 2 Eus ALT a Cd oe RAS p Crete eus ALT ae LL EL I T dL l l l T and EE E LLA s LLA re Gaz varende elec Gaz cagugeng Lui Whe qi als En dr CM ACHEN 3E Whe p7 Sal be TE EE w Ji lowe w i zc Place the cursor here and Place the cursor here and press the ENTER key to press the ENTER key to open the following setting open the following setting screen screen ee THE E d a a Level crine la 21 29 a Fal Ue F KL AE ESTEE ELLE T 2 Ee pH kids Lisez dee Ch Hop Lzuc eve p Attack OD i TT TETTE T Wu Lode la Es m I e 8 ee KD C HEEEH 0 a BU nnt LAN VR I ser Uja r T d ve 18 59 n I i B ors a ors i Ap L cc LE E LL I L LE SPE pen dees Hr xum Ga te H p 4 XU mb db Ane Setting 1 Combination Sets a combination of trigger conditions set for each channel lt For Trigger gt Level OR Starts stops capturing data when at least one of the specified trigger conditions is met Each condition is Level operation Level AND Starts stops capturing data when all of the specified trigger conditions are met Each condition is Level operation Edge OR Starts stops capturing data when at least one of the specified trigger conditions is met Each condition is Edge operation Edge AND Sta
93. socer meth Lms Janw Tettinas older EE D Lle Some i DEES ED V Mone cq o Le hi un Eoee MI EMT LEE M rei St T35 Toe Mr saft S Ini ILE T cii Lance Setting 1 Folder Specify a folder to which you want to capture or save data Refer to page 3 41 File box for details File Specify a file to which you want to capture or save data Refer to page 3 41 File box for details 2 3 Name Type Set how a data file should be named Auto Automatically supplies the file name Example 20050101 123456 UG GBD Number part File creation date The file is created on January 1 2005 12 34 56 in this example UG User number of the user capturing data UG Guest U1 User 1 U2 User 2 GBD Data format GBD Binary data CSV Text format Arbitrary Data is captured to a file with an entered file name Sequential number A file is created with an arbitrary file name that has been en tered followed by a sequential number Example If the file name is TEST First time TEST SEH1 GBD Second time TEST SER2 GBD Third time TEST SER3 GBD If the same file name already exists _CP is added to the end of a file name to prevent overwriting The asterisk represents a number Example TEST CP1 GBD 4 File Type Sets the file format used to save data GBD Creating a data file in Graphtec s proprietary binary format Data tampering can be prevented CSV Creating a data file in text format Replaying on the G
94. t 1 m 5 per set Needle shape K type HIC 410 100 to 300 C Class 1 Cord length 1 1 m thermocouple Stationery surface K type RIC 420 30 to 400 C Class 2 Cord length 1 1 m thermocouple L type stationery surface K type RIC 430 30 to 600 C Class 2 Cord length 1 1 m thermocouple Mini connector for K type HIC 440 5 per set Connectable thermocouple Wire diameter of Mini connector for K type RIC 441 2 per set Connectable thermocouple Wire diameter of thermocouple 2 per set 0 65 mm End terminal M3Y terminal Mini connector for T type RIC 450 5 per set Connectable thermocouple Wire diameter of Mini connector for T type RIC 451 2 per set Connectable thermocouple Wire diameter of thermocouple 2 per set 0 65 mm End terminal M3Y terminal 1 Allowable temperature range 25 to 80 C 2 Sold only in Japan 2 2 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 2 Checks and Preparation 2 3 GL220 Nomenclature and Functions This section describes the names and function of parts of the GL220 Operation status LED POWER ON when the power is ON Monitor START ON during data capture CHARGE ON while the battery is charging ER cE
95. t terminal as shown below ll Logic alarm cable ee CK B 513 Option Logic Pulse Specifications Number of input channels Input voltage range 0 to 24V max single ended ground input Threshold level Approx 2 5V Approx 0 5 V 42 5 to 3 V Logic input and pulse input are switchable Trigger input external sampling input specifications Alarm output specifications Number of output channels Output format Open collector output 5V pull up resistance 10 KQ See the next page for details on alarm output ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 2 Checks and Preparation Internal Equivalent Circuit of the Input Output Circuit e Alarm Output 45V Maximum ratings of the transistor for alarm output VCEO Collector emitter voltage 30 V IC Collector current 0 5A PC Collector dissipation 0 2W The maximum ratings must not be exceeded GND 5 to 24V Example of external Required for an ER inductive load such ALARM as a relay Load L 2SC2411K l DC Logic Pulse Input 5V 5V 100K Comparator 68K LOGIC PULSE n X 220K GND I V V e Trigger Input 5V 5V 100KQ Comparator TRIGGER pone SAMPLE 220KQ MV V 2 8 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de
96. ter sets the GL220 s display language ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d amp gt gt CHAPTER 3 Settings and Measurement 5 10 Return to default settings Returns all the settings to the factory defaults 5 11 Information Displays system information 5 12 Demo Waveform Mode This parameter displays demo waveforms without analog signal input Selection item The demo waveform is not displayed The demo waveform is displayed 5 13 Game Several games are available The score is stored for each user S SR THEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 6 FILE menu Performs file related operations The items to be displayed vary depending on the operation mode Refer to page 3 13 for details on the operation modes lt Free Running Status gt pid or Double Screen Replay Status HH ll i OW Ces e DO RW ka AWA beet Ar rv 90 9 ha ai I Lid Lun O1 x ETT x SEHE ab Je ie A cl F IS Tus Ul d Pisa 7 We m V Pa po spares VED vors i E PEE NIRE tee ver l F l TEE Pat er c SE zer VED Yor A A AHA A AAA LG UR STOO gt L LE TE DAT OD PR Loft EA TET AU Dr sftEPAITE SSS LL Ma T T a Lawn Eerie DE dud y ge TE xk Nr LEN HH Loe Yong
97. the LCD is ON 0 45A Recharging battery is not possible 8 5V When the screensaver is 0 37A Recharging operating battery Is not possible Normal condition LCD brightness is set to MAX External dimensions 194x117x42 mm Weight 1 520g Vibration tested conditions Equivalent to automobile parts Type 1 Category A classification 1 Excluding the AC adapter and battery 4 2 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 4 Specifications Internal memory devices Memory capacity Internal memory Approx 2GB Flash Memory USB memory Unlimited However one file must be 2GB at the maximum Memory contents e Setup conditions Measured data e Screen copy PC Interface Interface types USB Full speed Functions Data transfer to the PC realtime memory e PC control of the GL220 USB functions USB drive mode Transfers and deletes file from internal memory Realtime data transfer speed 10 ms 1ch maximum Monitor Display 4 3 inch TFT color LCD WQVGA 480 x 272 dots Backlight life 20000 hr when brightness is down to 50 depends on operation environment Displayed languages English French Japanese German Chinese Korean Backlight Screen saver function provided 10 30 s 1 2 5 10 30 60 min ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de
98. tting value 0 5 of range For 1 V range 1 V 0 5 0 005 V Conditions met here in rising Conditions met here in falling 4 USER settings By switching between users using the USER Setting you can easily read out different setting conditions that have been stored Beebe Haa Macro file name File Specify a file name Name gt Press right key to execute S SRLTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 4 1 USER settings Setting Specify the user name You cannot specify it as Guest Department name Specify the department name You cannot specify it as Guest Setting conditions Switches between Guest User1 and User2 Since setting conditions are stored for each user they can be called up easily by simply switching the user switch Interface commands for GL220 can be described in a text file and read in GL220 will operate asdescribed in this file lt Macro operation flow gt Create a macro file using a text editor on your PC save the file with extension GMA Copy this file to a USB memory and then connect the USB memory to GL220 Select the macro file and run the file e Macro file name Execute Macro GL220 executes the commands EXE as described in the mac
99. upplied AC adapter In environments where there is a lot of noise or where the power supply is unstable we recommend that you ground the GL220 2 When a high voltage signal cable has been connected to the main unit s analog signal input terminal avoid touching the leads of the input terminal s signal cable to prevent electrical shock due to high voltage 3 Ensure that the GL220 s power source is positioned so that it can easily be disconnected Notes on Functions and Performance 1 Be sure to connect the main unit to an AC or DC power supply that conforms to the rated range Connection to a non rated power supply may cause the main unit to overheat and break down 2 Do not block the vent on the main unit Continued operation with the vent blocked may cause the main unit to overheat and break down 3 To avoid malfunctions and other damage avoid using the GL220 in the following locations e Places exposed to high temperature and or high humidity such as in direct sunlight or near heating equipment Allowable temperature range 0 to 45 C 0 to 40 C when a battery pack is mounted Allowable humidity range 5 to 85 R H Locations subject to excessive salt spray or heavy fumes from corrosive gas or solvents Excessively dusty locations Locations subject to strong vibrations or shock Locations subject to surge voltages and or electromagnetic interference 4 If the main unit becomes soiled wipe it off using a soft dr
100. wer Cable tengih List of Options of 15 8 V Built to order 0 32 1 0 x 1 6 x 5000 mm 0 32 1 0 x 1 6 x 5000 mm TC200 TD1000 5 per set part 1 m 5 per set couple couple L type stationery surface K type HIC 430 30 to 600 C Class 2 Cord length 1 1 m thermocouple Mini connector for K type thermo RIC 440 5 per set Connectable thermocouple Wire diameter of couple 5 per set 0 65 mm End terminal M3Y terminal Mini connector for K type thermo RIC 441 2 per set Connectable thermocouple Wire diameter of couple 2 per set 0 65 mm End terminal M3Y terminal Mini connector for T type thermo RIC 450 5 per set Connectable thermocouple Wire diameter of couple 5 per set 0 65 mm End terminal M3Y terminal Mini connector for T type thermo RIC 451 2 per set Connectable thermocouple Wire diameter of couple 2 per set 0 65 mm End terminal M3Y terminal 1 Allowable temperature range 25 to 80 C 2 Sold only in Japan 4 8 ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 4 Specifications External Dimensions POWER OSTART CHARGE GRAPHTEC CS o ae Re cursor DISPLAY EE D ml D midi LOGGER GL220 EE REVIEW Z 000000000000 000 0 OO 0 000000 0 000 DO 00 0 0 0000000000000000006 M4 L5 insert screw o 0 87 00000000000 0 O00 pomo o pom 0 6
101. will switch displays as shown below MONITOR POSITION PHT MR FEME D J HLL HEI KI D AIDS RA AE 8 TI m Aldra Hr i n g BEI ag rer Displays digital values Allows changing of the span value Allows changing of the position Allows turning ON OFF of the default status waveform amplitude waveform up down position waveform display Channel change VA keys Range can be changed in units of 1096 Channel change VA keys Amplitude change lt P gt keys Channel change VA keys Position change 2 keys Change available Voltage 8 steps Position change i keys Change available ON OFF Temperature 6 steps Change available 10 steps of range Data is captured even if OFF is set When ALL is set setting values for CH1 is reflected on other channels When CH1 is OFF ALL Cannot be set ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen d ec CHAPTER 3 Settings and Measurement 2 TIME DIV 4 QUIT LOCAL 6 ENTER 3 8 Press the left right key of the TIME DIV key to change the time axis display width Pig Buh Sy t i TT 99 Open the settings window to capture data For details on settings see 3 4 Setting Menus on page 3 16 Poe HP See ee 4E T FEE FE LU HES Vi pz TE fe v ry This key is primarily used for the following operations To cancel a setting during m
102. ww althen d 9 CHAPTER 3 Settings and Measurement 2 3 External sampling Enables or disables external sampling When the external sampling function is enabled data is captured at the shortest intervals and retained temporarily This retained data is updated at the shortest intervals When an external sampling pulse is received the retained data is written to the memory See the following figure Therefore the maximum error in time between the actually captured data and the external sampling pulse is the same as the shortest interval Refer to the next section 2 4 AC line filter for details on the shortest interval Input signal Sampling interval Shortest interval External Sampling pulse Data for this Data for this Memory capture data 7 CHECKPOINT e If the external sampling function is ON the external input cannot be selected for the trigger setting If the external input has already been set the trigger will be set to Off e When you measure signals with high noise levels set the AC line filter described in the next section to ON 2 4 AC line filter Enables or disables the AC line filter while external sampling is enabled Enable this setting to enable the digital filter When you use external sampling and measure signals with high noise levels set the AC line filter to ON The shortest interval is displayed under the settings A DATA TnTG USON org eee AA Fe o d Sebtnd
103. www althen d 3 9 CHAPTER 3 Settings and Measurement 9 REVIEW This key is used to replay captured data e During Free Running replays captured data The screen used to specify the data replay source file appears specify the file you want to replay While capturing data recently captured data is replayed in two windows LE i i ary 10 DISPLAY This key is used to switch the window mode You can switch the window mode during Free Running when capturing is stopped and Capturing Pressing this key switches the window display as follows lt Waveform Digital Screen gt Displays the waveform and the digital values The setting can be changed using the SPAN TRACE POSITION keys lt Expanded Waveform screen gt Displays only the waveform expanded in full screen mode lt Digital Calculation Display screen gt Displays digital values and two calculation results in large letters The calculation settings can be made using the Data menu Refer to page 3 27 for details Use the lt lt gt gt FAST FORWARD keys to change the display mode The calculation results are displayed only in All Mode Refer to page 3 9 for details on All Mode S TRLTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www althen de CHAPTER 3 Settings and Measurement 11 CURSOR ALARM CLEAR This key is used to toggle between cursors A and B durin
104. y cloth Use of organic solvents such as thinner or benzene causes deterioration and discoloration of the outer casing b Do not use the GL220 in the vicinity of other devices which are susceptible to electromagnetic interference 6 Measured results may not conform to the stated specifications if the GL220 is used in an environment which is subject to strong electromagnetic interference ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 e info althen de www lthen de Introduction 7 Insofar as possible position the GL220 input signal cables away from any other cables which are likely to be affected by electromagnetic interference 8 For stabilized measurement allow the GL220 to warm up for at least 30 minutes after turning it on About Registered Trademarks Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U S and elsewhere e Other company names and product names included in this manual are registered trademarks or trademarks of their respective companies ALTHEN ALTHEN GmbH Frankfurter Str 150 152 65779 Kelkheim Telefon 49 0 6195 70060 info althen de www althen de To Ensure Safe and Correct Use To Ensure Safe and Correct Use eTo ensure safe and correct use of the GL220 read this Manual thoroughly before use e After having read this Manual keep it in a handy location for quick reference as n

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - 三共電子  Samsung 2333T Korisničko uputstvo  K408取扱説明書を見る  SECTION I Bill of Materials    RT-ZZ80 User Manual  Operating instructions Mode d'emploi Instrucciones de  Gemini eReader D09  Model 8540 60V/30A/150W DC Electronic Load - HIK  GE A4021 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file