Home
User Manual SenzaNet & WMSPortal - Panasonic Industrial Devices
Contents
1. ul m Wullsoft Install System vz 30 Rescan Cancel Picture 3 Prompt for Hardware Picture 4 Hardware configuration E Senza Technologies GmbH 7 von 39 vs 8 LY J LA Leveraging Power of Wireless User Manual SenzaWMS If there is more than one possible SenzaCoordinaor you can select the Com port where the Gate is connected and you can also select the language for the WMSPortal then press configure If the detected Port is empty press rescan unplug and plug in again the Coordinator and try it again 1 3 Starting WMSPortal Software The WMSPortal Software starts automatically after the installer has finished You can also start it from the Start menu m SenzaMonitoring Configuration Search j SenzaMonitoring Help and Support 6 Handbuch Bin uk Uninstall senzaMonitaring v 1 3 m C LS gem ae un e Ej i Shut Down iE start ee By mW g D Inbox Micr fm 2 Windows A Ser You can also Start the Application by entering the URL http localhost 8080 WMSPortal app in your browser E Senza Technologies GmbH 8 von 39 Leveraging Power of Wireless User Manual SenzaWMS 2 USER MANUAL 2 1 How to Setup the Network 1 Install the WMSPortal 2 Power each individual SenzaBlock 3 Place your blocks at the desired location 4 All blocks will b
2. E Senza Technologies GmbH 22 von 39 0 Leveraging Power of Wireless User Manual SenzaWMS Number of Input Output Channels at a time 1 Analog 4 20 mA a 0 20 mA 1 RF Frequency 2 4 Ghz RF Sensitivity 98dBm RF Data Transfer Rate 250 Kbps RF Max Ee upute Power 12 Battery 1 min E ____ sampling rate 3 24 months Operating temperature 10 C to 85 C Notel The power consumption for Impulse or 1 configuration will be higher compared to analog or internal temperature sensor E Senza Technologies GmbH 23 von 39 Leveraging Power of Wireless User Manual SenzaWMS 2 5 11 1 Comparison Graph for multiple SenzaBlocks Black Darstellung Mehrfache Darstellung Diagramm fiir Block s DMSB104 DMSB105 260 MT 18200 JEOU 2T 0U 22D 230 PDU Q100 JUD UOU 09000 10 00 DMSB104 DHMSDB05 Picture 15 Compare diagrams With the function Show Diagram you can choose the chart of values from a specific time interval The user can select simultaneous charts from more then one Block if they are all of the same sensor type In this case different values can be compared simultaneously with each other 2 5 11 2 Live Stats The Live Stats is a live diagram of the last 10 or more values from one or more Blocks of your choice amp 1 Netzwerk Status
3. Pin9 gives out a current limited VCC voltage level signal This will loop through your device and back to SenzaBlock If you have a meter with an electronically switch like a MOSFET transistor you have to connect Pin9 D IO supply to the positive input of your meter If you have a relay or other kind of switch you can connect Pin9 at any pin from your switch The output of your meter or the other side of your switch has to be connected to Pin8 impulse input 1 8 9 DIO supply Impin The other possibility is if you have a meter or another device which is external power it and read the impulse out E Senza Technologies GmbH 33 von 39 Leveraging Power of Wireless User Manual SenzaWMS 1 8 14 In that case you have to connect the device output to Pin8 Impln from SenzaBlock Additionally you have to connect the ground from your device with ground of SenzaBlock Pin14 The signal should have its current limited to max 50mA 2 8 Default network parameters By default SenzaBlocks are configured as temperature sensors You do not need to add them to the software If you want to connect a different sensor you must can simply change the sensor type of a SenzaBlock and then configure it with new settings 2 8 1 LogFile You can find the log file of the WMSPortal in C Program Files SenzaApplications SenzaMonitoring log You will find the log file of Apache Tomcat in C Program Files SenzaApplications To
4. 1 Daten anzeigen Live Diagramm Celsius A AONO O 13 32 13 33 13 34 13 35 temp2 temp1 temp3 Picture 16 Live diagram from 3 blocks E Senza Technologies GmbH 24 von 39 Leveraging Power of Wireless User Manual SenzaWMS 2 5 11 3 Alarmlist 3 30 07 7 07 00 PM BLOCK CFG FAILED Configuration failed after 5 retries 3 30 07 5 42 05 PM block 3 BLOCK CFG FAILED Configuration failed after 5 retries 3 30 07 5 40 58 PM blocks BLOCK CFG FAILED Configuration failed after 5 retries 3 30 07 5 38 07 PM Block 4 BLOCK CFG FAILED Configuration failed after 5 retries 3 30 07 5 23 49 PM Block 7 BLOCK CFG FAILED Configuration failed after 5 retries 3 30 07 4 46 29 PM Block 2 IO Action Kontakt ist geschlossen 3 30 07 4 46 11 PM Block 2 IO Action Kontakt ist geschlossen 3 30 07 4 30 36 PM Block 2 IO Action Kontakt ist geschlossen 3 30 07 4 30 35 PM Block 2 IO Action Kontakt ist geschlossen 3 30 07 4 27 29 PM Block 2 BLOCK CFG FAILED Configuration failed after 5 retries 3 30 07 4 27 05 PM Block 2 IO Action Kontakt ist geschlossen Picture 17 Alarm table In the event list table you can trace all events with the corresponding timestamp Listed events are Event on the 1 sensor or if a configuration package send by user is not reaching its destination 2 5 12 Time planner Certain tasks can be defined i
5. Day 51atun Jal SenzaWMS Please also notice that depending on the battery capacity the battery status can vary a lot Noticel If you think battery should be full and it is giving a red battery status then please check chapter 2 6 for correct settings of the jumpers If the jumper is not set correctly for the corresponding battery voltage then the Battery Status can be wrong Notice2 When you are using common 9V batteries it happens often that the voltage monitoring drops too fast It also means that the battery sign becomes red too fast even though there is enough power to run for longer time 2 5 1 2 Delete Blocks To delete SenzaBlocks from the network have to select the Blocks and confirm the cancellation 2 5 1 3 Change Block configuration Pi With this dialog you change the configurations of the Block 2 5 2 Show Data Block Name Description Last Value Value Type Last Data Message E SB104 StarterKit Block I Celsius 1 16 07 4 10 04 PM CET Starterkit Block II 1x l1 1 16 07 4 10 09 PM CET SB106 Starterkit Block III Celsius 1 16 07 4 10 14 PM CET Picture 8 Show data The data display is very similar to the network status with the difference that here the health cycle of the network is not monitored but the last sent values of a single Block If no value is displayed there is no Block value identified E Senza Technologies GmbH 15 von 39 User Manual SenzaWMS 2 5 3 Ass
6. Setup Welcome to the WMSPortal Setup Wizard This wizard will quide vau through the installation of wMMSPartal It is recommended that vau close all other applications before starting Setup This will make it possible to update relevant system Files without having to reboot your computer Click MexE bo continue Picture 1 Autorun Setup The installer will check your system for the required software and install the following components if there is no other version already installed on your PC E Senza Technologies GmbH 5 von 39 Leveraging Power of Wireless User Manual SenzaWMS P wMsSPortal Setup JL Bl xl System Check poda System requirements O E S enza Technologies Java Runtime Enviroment 1 6 PostgreSQL 8 2 Windows Version an Ok Microsoft Windows XP found Apache Tomcat 6 0 v Browser IE 7 Ok Internet Explorer 7 Found 4 Administrator rights Ok Current User is an Administrator WMSPortal including Handbook and tools Acrobat Reader 8 11 optional Nullsoft Install System vz 30 lt Back Cancel Picture 2 Systemcheck During the installation of the Enterprise version you will be ask for a software key please enter here the delivered key If you enter a different key you will not be able to add a new network to the WMSPortal It is very important that you leave the Port 8080 as predefined As later on you will start the WMSPortal from your browser
7. and not if it is continuously crossed Setpoint Low This parameter allows you to set the lower limit of a setpoint on the defined sensor A message will appear in the alarm table if this setpoint has been reached Message will be thrown only once whenever the limit is crossed and not if it is continuously crossed Initial value A start value is important to use it as an offset for a specific value Also this initial value is important when counting the impulses to start with a predefined value If the value is set to zero and the Block is started up again then the whole process starts with zero Otherwise it is also possible to start with another value e g if the meter is connected with an already existing value You can also change that later in the menu Update Block Multipl Factor Multiplication Factor is a number to which the sampled sensor value can be multiplied to Default value is 1 If the value is different than 1 the multiplication factor will have priority towards the initial value Units This is the desired unit denomination which will appear in the table This value has no influence on the value Directly after the confirmation saving the parameters through the user the changes are active E Senza Technologies GmbH 20 von 39 Leveraging Power of Wireless User Manual SenzaWMS The Block receives automatically the configuration parameters from the gate when switched on The Block will also receive the confi
8. with the address http localhost 8080 WMSPortal app If you change this port then you will have to start the WMSPortal with http localhost YOURPORT WMSPortal app Please note down the user and password which you enter for the Tomcat Webserver if you install it manually You can select Install tomcat as service on the advanced installation With this selection Tomcat will be started automatically with each restart of your PC 1 1 1 Manual Software Installation If you have already installed Tomcat PostgreSQL or J ava on your machine and you do not wish to reinstall these applications you still can use the Installer It will automatically detect the installed components if the version is same If you want to use another version of Tomcat or PostgreSQL to work together with the WMSPortal you have to follow up the following steps 1 1 1 1 Existing PostgreSQL Installation In case you already have installed ProgreSQL 8 2 enter a ProgreSQL user and password in the installer assigning the corresponding rights to create DB insert select and update tables If you want to use any E Senza Technologies GmbH 6 von 39 Fra 5 a Leveraging Power of Wireless User Manual SenzaWMS other version of postgreSQL you can import the StarterKit sgl from the CD to your Installation You have also to modify the login data in the WMSPortal xml located on your hard disk at following location PROGRAM FILES Apache Software Foundati
9. 4 20mA and the ground line from analog sensor 14 If the sensor needs an external power supply and you want to power SenzaBlock and sensor together you have to be careful about the maximum supply voltage of 16V for SenzaBlock 2 7 3 PT100 Sensor There is a possibility to connect an external PT100 sensor to the SenzaBlock The measurement temperature range is 50 C to 4200 C The connection diagram is as shown below 1 14 Gnd The Readings might vary in between 2 for a given temperature input 2 7 4 Temperature Sensor on board There is as default sensor an on board with a 10bit temperature resolution E Senza Technologies GmbH 32 von 39 Leveraging Power of Wireless User Manual SenzaWMS Note The sensor is mounted on the motherboard in enclosure and will measure the temperature inside the enclosure If you wish to measure outside temperature you can drill a hole on the side of the enclosure This sensor is maintained mainly for demonstration purpose 2 7 5 Impulse The impulse interface has an optic isolated input to detect pulses with rising edges from meters switches or other sensors There are different possibilities how to generate an impulse For that there are also different connections to SenzaBlock Pulses can easily generate through a switch or a meter with a kind of a switch internal MOSFET transistor For that external power is needed which also will be provided from this module
10. Battery Status SB110 Here is the link table between battery used and pin selection By Default J umper is set to 9V Battery Input Note Inaccuracy of Sensor values when battery goes low When the battery power is going low the sensor values can become inaccurate because of power supply fluctuations Note Power Optimization options on the SenzaBlock Different ADC and DAC on the motherboard optoisolation of the input require extra power Standard SenzaBlocks are universal modules which offer multiple connection possibilities The high number of connection options is in direct relation to the high number of components and extra components require extra power E Senza Technologies GmbH 28 von 39 Leveraging Power of Wireless User Manual SenzaWMS Therefore there is up to 6096 power optimization possible on the SenzaBlock if a customer decides for a fix hardware configuration Note Effects when restarting SenzaBlock If you remove SenzaBlock from current you have to assume that the data which was lastly saved by the Block can be lost This applies particularly to longer store intervals and to meter impulse measurements 2 7 Connection Interfaces pong E it Fu m P E B T m 1 E i 3 i 2 E Picture 24 SenzaBlock connectors E Senza Technologies GmbH 29 von 39 0 Leveraging Power of Wireless User Manual SenzaWM
11. Picture 12 Add Sensor 1Y 06 uec doeet sea toties une E a pau E orsus Uds 17 FV WS BOCK m e HM 18 Picture 14 SenzaBlock Ca e M 18 Picture 16 Live diagram from blocks seseeesssssesseeeseeeee nennen nennen nennen nnns nnne nnns sina nnn nnn 24 Picture 15 Compare 24 Picur 17 Aladim gis 9 oan T 3 25 Picture 18 Preconfigured task 25 miei NE Add NG WB ASK MC 26 Picture 20 Network Routing 27 Picture 21 Star network table 27 Picture 22 Motherboard for SB110 with the Battery Status 28 Picture 23 Jumper Settings for Battery Status 5 110 28 Picture 24 SenzaBlock connectors s sseeeseseeeeeceeeeeeceeeaaaaeusesseeeeeeeeeeeeeeeeeeeesaauaasueeeeeeeeeeeeeeeesssaaaaaaaageseeeeees 29 E Senza Technologies GmbH 4 von 39 Leveraging Power of Wireless User Manual SenzaWMS 1 INSTALLATION GUIDE 1 1 Automatic Software Installation The Setup will start automatically If your configuration is not set for autorun activate autostart for your CD drive or execute the file NSIS WMSPortal 2 5 6 exe from your CD drive B wMSPortal
12. S Connector Details ow 2V 0 2V Analog sensor signal input ADO 20mA 0 20mA Analog sensor signal input 4 20mA 4 20mA Analog sensor signal input NC No External Connection Do Not Connect to any external Sensor Input Ll IO baa Current limited 30mA VCC output for contact supply gt nk DC supply Connect 9V Battery Fijos fro n E Senza Technologies GmbH 30 von 39 Leveraging Power of Wireless User Manual SenzaWMS 2 7 1 Power Supply for SB110 SenzaBlock can be powered with a positive DC supply from 4V up to 16V Voltages beyond the range connected to DC Pin13 will destroy the module Please also be careful with correct polarization As power supply you can use battery DC adapter or solar panel The only requirement additional to DC value is the minimum current force of 150mA Pin14 GND Pin13 DC 13 14 Batter GND 2 7 2 AD Converter SenzaBlock has an external Analog to digital converter with single ended connection interface The resolution of this ADC is 12bit and has an internal independent reference voltage of 2 048V SenzaBlock provides two Analog interfaces where you can connect an analog sensor with 0 2V sensor signal to Pin 2 or a 0 20mA Signal to Pin 3 or a 4 20mA analog Signal to Pin 4 E Senza Technologies GmbH 31 von 39 Leveraging Power of Wireless User Manual SenzaWMS AC oder DC You have to connect your sensor signal output to Pin2 ADO 2V or Pin6 AD
13. SB130 Lars Regal 8 10 07 3 58 58 PM i DODBDHE EE Picture 7 Network status The network status shows you the individual Blocks within the network Status is a column with red or green elements Cyclically the SenzaBlocks have to send a health message A red element means that the health message of a block has not reached More relevant to realize since when a Block has not send any message is the Last Health Time column A green button shows the continuous activity status LQ or Link Quality is a column which gives values between 1 to 256 The values show how good the RF quality from respective Block to his parent node is 1 means no values had been able to be issued 19 is quite a bad connection and 256 is a very good connection when the Block is mostly very close to his father node In this view you can also delete and edit Blocks from the network 2 5 1 1 Battery Status Blocks which are battery powered have a Battery Status column If power supply goes low the image will turn from green to red If the battery status is not known a question mark will appear there Please note that there is only the status low battery high battery and unknown when no battery information could be provided If the Health Status and Battery Status are both red that means most of the times that because of low battery the node is now off E Senza Technologies GmbH 14 von 39 Leveraging Power of Wireless
14. User Manual SenzaNet amp VWiMSPortal WMSPortal Version 2 6 9 E Senza Technologies Pi O 0 Leveraging Power of Wireless User Manual SenzaWMS TABLE OF CONTENTS 1 INSTALLATION GUIDE 1 1 1 1 1 1 2 1 3 AUTOMATIC SOFTWARE INSTALLATION MANUAL SOFTWARE INSTALLATION CONFIGURE THE WMSPORTAL SOFTWARE AND HARDWARE STARTING WMSPORTAL SOFTWARE 2 USER MANUAL 2 1 2 2 2 3 2 4 2 5 2 5 1 2 5 2 2 5 3 2 5 4 2 5 5 2 5 6 2 5 7 2 5 8 29 9 2 5 10 2 5 11 2 5 12 2 5 13 2 6 2 1 2 7 2 2 7 9 2 7 4 2 7 5 2 8 2 8 1 2 9 How TO SETUP THE NETWORK WMSPORTAL THE UPPER BUTTEN BAR THE ACCORDION MENU ON THE LEFT NETWORK NETWORK STATUS SHOW DATA ASSIGNING NEW EXPORT DATA SENSOR TYPES ADD NEW SENSOR TYPE ADD A NEW BLOCK BASIC PARAMETERS SENSOR 1 3 PARAMETERS SLEEP MODE AND MESH BLOCK TYPES TIME PLANNER ROUTING BATTERY amp POWER INFORMATION CONNECTION INTERFACES POWER SUPPLY FOR SB110 AD CONVERTER PT100 SENSOR TEMPERATURE SENSOR ON BOARD IMPULSE DEFAULT NETWORK PARAMETERS LOG FILE ACTIVATION IN SK801 E Senza Technologies GmbH 2 von 39 0O N UI 10 10 13 14 14 15 16 16 16 17 17 19 19 21 22 25 26 27 29 31 31 32 32 33 34 34 34 User Manual SenzaWMS 3 TROUBLESHOOTING 3 1 3 2 3 3 3 4 3 5 3 6 3 7 0 Leveraging Power of Wireless IN CASE THE BLOCKS DO NOT ANS
15. WER ON PING MESSAGES IF THE BLOCKS SEND THE DATA TOO SLOW ERROR MESSAGES COULD NOT FIND FILE PARAMETERS STARTERKIT PROPERTIES PROBABLY APPLICATION WAS NOT YET DEPLOYED THE APPLICATION CREATES PROBLEMS AFTER REINSTALLING A NEW JRE JAVA RUNTIME ENVIRONMENT IF THERE IS NO COM PORT INDICATED FOR THE GATE CONNECTION THE APPLICATION IS NOT DISPLAYED IN YOUR BROWSER DO THE FRAMES OF THE DIALOG WINDOWS LOOK THICK AND BLACK 4 APPENDIX 4 1 4 2 4 3 4 4 1 YEAR WARRANTY CE CONFORMANCE WEEE AND RoHS COMPLIANCE CONTACT E SENZA TECHNOLOGIES E Senza Technologies GmbH 3 von 39 35 35 35 36 36 37 37 37 38 38 38 39 39 Leveraging Power of Wireless User Manual SenzaWMS Tables of Figures Pic re T AUtorun 5 y SUC UNAS NECK EE TE 6 GS o RIONI Tt OLOR 7 Picture 4 Hardware configuration 7 PEUS WMO mio Mz T T m T 10 Picture 6 Timesync dialog R 11 Petrer ING WOU Sia E TTE A M cho cU RU On HU UU UN e 14 FUSS E OW Me Mz OE OO OESTE 15 SUIS 9 NS SIGMA NOW PC m 16 FC OS 10 F X ON Ce EE Om T S 16 Picture 11 Sensor type list lsssssssssesissssseeeseeee enne nnn nnn nnns nnnna nnn nnns sss sss sa saris rris asas anna 17
16. ad cycle is 2 it will release the stored buffer every 20 seconds Upload cycle should be always higher or same than store cycle so that at least one value can be sampled from the sensor The reason to use a store and upload cycle is to reduce radio communication You can give the Block a description of your choice You can give the Block a location of your choice 2 5 9 Sensor 1 3 Parameters E Senza Technologies GmbH 19 von 39 Leveraging Power of Wireless User Manual SenzaWMS Depending on the SenzaBlock model in use this gives permission to read one or up to 3 sensors or even send an output signal If you have a SenzaBlock model which allows you to read 3 sensors but you which to just one or two please set the third or second one as Disabled Sensor Type For the standard temperature sensor onboard please select Thermo C For connecting to your own sensor you have multiple choices AD analog impulse digital contact input analog or digital output PT100 which is dependent mainly on the SenzaBlock model which you purchased Have a look on the complete list of choices in chapter 2 5 11 Please note that if you change the sensor type all the history data of that sensor will be deleted Setpoint High This parameter allows you to set the upper limit of a setpoint on the defined sensor A message will appear in the alarm table if this setpoint has been reached Message will be thrown only once whenever the limit is crossed
17. age Close this browser window and try it again after restarting tomcat Tomcat didn t restart after useing Configtool or Configtool wasn t started before it means you have not started your SenzaCoordinator That has to be plugged into the USB port first so that it can be queried by the software Then you have to configure the COM Ports of your SenzaCoordinator with the Configuration Utility 3 7 Dothe frames of the dialog Windows look thick and black Then you have to switch to Internet Explorer 7 0 because there the frames are transparent E Senza Technologies GmbH 37 von 39 Leveraging Power of Wireless User Manual SenzaWMS 4 APPENDIX 4 1 1 Year Warranty SenzaBlock and SenzaCoordinator Modules from E Senza are warranted against defects in materials and workmanship under normal use for a period of 1 from the date of purchase In the event of a product failure due to materials or workmanship E Senza will repair or replace the defective product For warranty service return the defective product to E Senza shipping pre paid for prompt repair or replacement Repair or replacement at E Senza s option is the exclusive remedy This warranty is given in place of all other warranties express or implied 4 2 CE Conformance The Panasonic PAN4555 and the SenzaBlock modules complie with European EMC safety standards EN301 489 1 EN 301 489 17 EN 300328 EN50371 EN 60950 A declaration of conformity has also be
18. at Therefore a special care has to be taken while setting the sleep mode flag to the nodes Important Notice Avoid situations when child node is set a heartbeat which he can t synchronize to that of his parent For example If the parent has a heartbeat of 1 minute and the child a heartbeat of 10 seconds this means that the child will miss 5 from 6 heartbeat messages This can also lead to the dynamic switch to a different parent Also when setting a whole network in sleep first put in sleep the nodes at lowest level then the next lowest level and so on up to the SenzaCoordinator Same when taking a network out of sleep please start first with the nodes directly connected to SenzaCoordinator then their children afterwards their children and so on up to the lowest level Also take care that if nodes are in sleep their reaction time will be lower than usual and directly proportional to the heartbeat and the number of parents it has If you set the heartbeat of a SenzaBlock which is directly connected to SenzaCoordinator to 10 minutes and you would like to change the configuration parameters sometimes you will have to wait a maximum of 10 minutes for SenzaBlock to be in receive mode and confirm your message 2 5 11 Block Types A Table with Different Configuration of SB110 can be seen below Standard Mesh Operating Voltage 4 to 16V Battery 0 Power Stand E d Consumption 200 EE LL 0 0 mA ee
19. best in matters of data reliability Blocks have enough time to send all the desired data out When you set Ultra Low Power blocks have extremely little time to read out the sensors and also to communicate all their data out E Senza Technologies GmbH 11 von 39 0 Leveraging Power of Wireless User Manual SenzaWMS Power Saving Mode Ultra Low Power Standard High Battery Life Good Battery Life Less Battery Life Expectation Expectation Expectation Less Data Reliability Good Data Reliability High Data Reliability Example Example Example Heartbeat 30 Sec 5 Minutes 10 15 Minutes Very less Battery Life Normal Battery Life High Battery Life Expectation Expectation Expectation around 2 to be used only for setting Dense data Sampling years up the network Slow response from the very slow response fast response from the network from the network network With the changes in heartbeat just the Health message is affected This health message comes every heartbeat and is displayed in the Network Status Table This gives a positive status about each block Block Data which is visible in the Show Data Table comes in direct relation with the heartbeat In the Edit Block Dialog you can set the data cycle in relation the heartbeat 5 Senda ping data package to a specific SenzaBlock This function allows the user to check the status of each individual Block To access this f
20. e displayed under Assigning new 2 5 3 Allow to add the blocks to the system 5 When all blocks are added and shown as green in the network change the heartbeat to 15 or 10 minutes see Chapter 2 3 Note SenzaCoordinator has to be on for the lifetime of the wireless network If SenzaCoordinator is not in reach or not powered up SenzaBlocks will be disturbed and consume lot of battery in continuous search for SenzaCoordinator E Senza Technologies GmbH 9 von 39 Leveraging Power of Wireless User Manual SenzaWMS 2 2 WMSPortal E Senza Technologies SN stack X 2 Windows Internet Explorer EH Pa _ Cy 2 http localhost 88 wMSPortal app o z File Edit Favorites Tools Links Customize Links w abe E Senza Technologies SN stack 2 M 7 Page ga Tools SenzaNet A gt E Senza Technologies Networks x B 7 ff fl QO Network Status igni Show Data 1 Assigning New 1 Network Status Assigning New Monitoring Portal Add a New Block ne EI Export Data Sensortypes Add new sensortype Diagrams Activation Task Manager Reports Routing gt Done OE kim 7 Picture 5 WMS Portal The application has an upper task bar and a menu bar on the left side 2 3 The upper butten bar 1 2 3 4 5 6 7 Pic
21. en issued by E Senza Technologies In order to operate under E Senza s CE Certification OEMs integrators must comply with the following regulations OEM Labeling Requirements 1 The Original Equipment Manufacturer OEM must ensure that CE labeling requirements are met This includes a clearly visible label on the outside of the final product enclosure that displays the CE sign 2 OEMs must test final product to comply with unintentional radiators EMV before declaring compliance of their final product to the EMV Rules The module is designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions it may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Re orient or relocate the receiving antenna E Senza Technologies GmbH 38 von 39 Leveraging Power of Wireless User Manual SenzaWMS 2 Increase the separation between the equipment and receiver Connect equipment and receiver to outlets on different circuits or Co
22. ers have to be defined in the registration window E Senza Technologies E Senza Technologies GmbH Model SB 120 Sr C ID F FF FF FF Operating Frequency 2 45GHz Operating Voltage 5V To 16V DC Made in Germany Picture 14 SenzaBlock Label Almost all parameters defined in this dialog except MAC and BlockID can be updated later in the Menu Update Block E Senza Technologies GmbH 18 von 39 Leveraging Power of Wireless User Manual SenzaWMS 2 5 8 Basic Parameters Block type Block name Block ID Upload cycles Description Location When you add a SenzaBlock you have to choose the Block Type Block type is mentioned as Model on the label of your purchased block For more information on the different type of SenzaBlock models you can see the chapter 2 5 11 If by mistake you enter a wrong block type the block itself will correct that with the first message coming from the block with the respective MAC MAC ID is a hexadecimal number mentioned on the label of your Block and is a unique number worldwide You can give the Block a name of your choice Block ID is a hexadecimal number of maximum 4 digits that can be chosen freely by the user and which must be unique in the network The upload cycle defines in which cycle SenzaBlock should transmit the stored buffer or the single sampled data value It is defined in n heartbeat which means that if the heartbeat is 10 seconds and the uplo
23. f the Blocks as they form a chain If this chain is interrupted the radio communication is down If the Block is displayed as red that means that the Block cannot be reached anymore For more information of the mesh communication please check chapter 2 5 10 E Senza Technologies GmbH 26 von 39 Leveraging Power of Wireless User Manual SenzaWMS SenzaGate block id 2 Black 5 block 3 Picture 20 Network Routing Graph 2 5 13 2 Routing table In this table each individual route is shown and displayed with the last send timestamp 06 03 07 15 33 06 06 03 07 15 33 01 Picture 21 Star network table 2 6 Battery amp Power Information The SB110 can be powered with 9V batteries The block is also available on request with 3V input In order to have the correct Battery Status the user needs to choose the correct voltage selector for the battery used For this there is the possibility to change the jumper position on the motherboard E Senza Technologies GmbH 27 von 39 Leveraging Power of Wireless User Manual SenzaWMS Fa E TT LI x 3 EMMEOCODOD OOOO DOr Oooo Ws AE f F PE te iL i n ue LES M NN F P _ no IT Picture 22 Motherboard for SB110 with the Battery Status Pins JP18 9V 2 1 Batt V V SIt V SIC NE 12V 6 5 Voltage Selector Picture 23 Jumper Settings for
24. guration packet as it is stored in the database the moment it is switched On 2 5 10 Sleep Mode and Mesh Sleep mode and mesh are very special features which deserve an extra chapter The reason why a sleep mode is needed by a SenzaBlock is that if SenzaBlock is in sleep mode the power consumption is between 10 200UA depending on the model If SenzaBlock is not in sleep mode it is either in receive or transmission mode where it requires 40 50mA which is a factor of 250 5000 times This difference has a dramatic influence on the battery life Mesh network means that SenzaBlock can connect not only directly to the SenzaCoordinator but also to other nodes SenzaBlock will have a first preference for SenzaCoordinator since it is defined that SenzaCoordinator is main powered and able to process requests from SenazBlock at any time In case SenzaCoordinator is not available or the link quality is too bad SenzaBlock will try to connect to another SenzaBlock and send all requests to SenzaCoordinator through it SenzaNet is a dynamic mesh network The characteristic of such a network is that the SenzaBlocks are able to find a new route to SenzaCoordinator if their parent route fails As the whole network is acknowledgement based any message which doesn t reach its destination gets no confirmation When even after several retries such messages don t go through SenzaBlock will go into a phase to search for another SenzaBlock to carry his messages to t
25. he SenzaCoordinator In order not to increase network traffic whithout end SenzaNet is designed only for a three level communication No node at the third level will allow other nodes to connect to it The role of SenzaBlock is therefore not only to process his data but also to serve nodes which are in neighbourhood serving requests coming from parent and child nodes If child nodes need to send due data or alarm messages or if parent node send user requests to the SenzaBlock this should be able to answer independent from his sleep mode when he is not even in receive mode The most important question is how does a SenzaBlock manage to sleep while it is a mesh node and still perform network communication serving children and parent nodes For an ultra low power consumption a special TDMA time division multiple access mechanism is in place the network is synchronized up to milliseconds This gives chance to the network to wake up to the highest common factor from the heartbeat within a tree branch This also means that the heartbeat of a child should always be smaller than and a factor of the parent node E Senza Technologies GmbH 21 von 39 Leveraging Power of Wireless User Manual SenzaWMS If the network is perfectly synchronized and all the heartbeat is common the nodes will all wake up at the same time communicate and go back in sleep SenzaNet is yet even more flexible since it allows any node to have its own heartbe
26. igning new When you turn on a block for the first a Network Status 1 Assigning New Leveraging Power of Wireless time it will first try to get assigned into the network and it will be listed in this Panel this block for your network The following blocks waiting for assingment You have the choice to all f mac Temporary Address status Date OU have e choice tO allow or 4711 1 2 70 11 17 36 AM If you allow this block the normal Add Picture 9 Assigning new Block dialog will popup with the settings default If you deny then the block is not allowed to communicate with anybody in the network 2 5 4 Export Data Eingabeformular f r den Datenexport Block ID September I 2005 gt In den Zeitr umen 11 12 13 14 15 16 18 19 20 21 22 23 25 26 B 28 29 September IJ 2006 gt 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 B 28 29 Abbrechen Picture 10 Export data With this dialog intervals can be selected out of the database to process a data export of a single Block An efficient data analysis can be performed exporting the Block data to a Microsoft Excel format We recommend to save first the exported file on your PC and then to open the file The file will be exported into a csv format which can be opened easily with Microsoft Excel Please careful because sometimes the data is not opened properly with Micros
27. mcat apache tomcat 5 5 17 logs or in C Program Files Apache Software Foundation Tomcat 6 0 logs 2 9 Activation in SK801 When you have acquired the EvalKit SK801 this will be provided with a 3 months full WMSPortal server license After 3 months the product will be reduced just to a basic functionality network visualization and network configuration We would be very much pleased if you enjoyed our full version product and would like to purchase the full license For that please contact sales e senza de give your purchase order number and we would be happy to make an offer on how to use the complete server version E Senza Technologies GmbH 34 von 39 Leveraging Power of Wireless User Manual SenzaWMS 3 Troubleshooting 3 1 In case the blocks do not answer on ping messages 10 11 12 13 While the application is running the configuration utility has to be closed Resend the configuration parameters at change Blocks reconfiguration If you receive messages of the Blocks in the log file it is possible that they are not synchronized You should do a time synchronisation s 2 3 Remove the Blocks from the User Interface restart them detach attach the power connector and add them again to the application Check if the SenzaGate is connected to the USB port and that you receive a ping respond a Stop the Tomcat server b Check the COM port starting the configuration utility and sending ping
28. n the time planner Delete or Change 2 5 12 1 Task list Preconfigured are the following tasks 1 Netzwerk Status 1 Daten anzeigen Auftragsliste Beschreibung N chster Termin Wiederholung EN m Export all Export all Blacks every day 07 03 07 10 06 50 w chentlich Daily TimeSync of all Gates 06 03 07 15 17 20 taglich CleanUp Removes all datas alder than 1 week DataCleanup 06 03 07 15 17 20 taglich Picture 18 Preconfigured task list E Senza Technologies GmbH 25 von 39 Leveraging Power of Wireless User Manual SenzaWMS 1 Export All With this task all Block data is daily exported in a defined directory on the server Of course you can modify the location 2 Time synchronization With this task your system will be time synchronized once a day with the SenzaGate 3 CleanUp in this task old data is erased out of the database 2 5 12 2 New Task With this menu you can define choose or configure tasks out of a list Neuer Auftrag x March XX 2 M T We T 1 N chste 5 NI 7 8 9 Ausf hrung 11 12 13 14 15 16 i8 19 20 21 22 23 eo 260 2 28 29 30 0 00 v Picture 19 Add new Task 2 5 13 Routing 2 5 13 1 Routing Graph This graph shows the network routes Your network configurates itself dynamically when you start each Block It will search for the father node with the best signal strength After that configuration we do not recommend to you to change the position o
29. nsult the dealer or an experienced radio TV technician for help 2 The SenzaBlock RF Module may only be used with antennas that have been tested and approved for use with this module 4 3 WEEE and RoHS Compliance All products from E Senza are WEEE and RoHS conform 4 4 Contact E Senza Technologies Free technical support is included with every products sold E Senza Technologies GmbH B cklestr 82b D 78467 Konstanz Tel 49 0 7531 36599 10 Fax 49 0 7531 36599 29 Technical Support support e senza de WWW e senza de E Senza Technologies GmbH 39 von 39
30. oft Excel and the values are displayed wrong To check if the data is correct please open the file in another text editor 2 5 5 Sensor Types The function sensor types shows you a list of every sensor that can be connected to a SenzaBlock You can add change or delete every sensor type you wish to connect to E Senza Technologies GmbH 16 von 39 User Manual SenzaWMS Leveraging Power of Wireless Initial Value Multipl Factor Thermometer F Temperatur CIE A wee e f s 3 v WB a Picture 11 Sensor type list 2 5 6 Add New Sensor Type New SensorSet airs 37 Picture 12 Add new Sensor type 2 5 7 Add a New Block E Senza Technologies GmbH In this dialog you can define the sensor types With Initial Value you can add the initial values and determine the scalable factor It is also possible to insert units directly Disabled means there will be no sensor read 17 von 39 Leveraging Power of Wireless User Manual SenzaWMS Add New Block Edit Block Basic a Basic Sensor 1 Blocktype SB120 A Sensor Type Block Name Block Setpoint High MAC 001EAA0000001103 Setpoint Low Initial Value Multipl Factor Store Cycle n Heartbeat Units Celsius yore ius n Heartbeat Description Location Picture 13 Add Blocks This function allows you to add Blocks to the network All Block paramet
31. on Tomcat 6 0 conf Catalina localhost Enter here your database user password and database name Save the file and restart Tomcat 1 1 1 2 Existing Apache Tomcat Installation In case you have already installed Tomcat5 please import the WAR file from the CD manual installation Tomcat over the Tomcat Manager If the standard Tomcat service is running you can achieve this by opening the browser at port 8080 http localhost 8080 Go to Tomcat Manager and load the WMSPortal war file from the CD If you have already installed Tomcat6 the installer will find it and deploy the corresponding files Note Third Party Software Version It is important that the version ID of your existing installations correspond to the one mentioned on the CD Installer If the Installer is supposed to install Tomcat 6 0 and you have Tomcat 5 0 on your PC the installer will install the new version 1 2 Configure the WMSPortal Software and Hardware The Software installer will ask you to Plug on the Coordinator If you do this the first time the Windows Hardware Wizard will start You can simply click on next in the WMSPortal installer and the hardware driver will be installed automatically D wrsportal setur E Hardware Setup Configurator Connect the Gate to USB and press Next M E Sen Za Basic WMS setup O E Sen Za Not on Hardware Wizard Technologies Technologies MNNNEENEEENN Cc Language
32. ort indicated for the gate connection This problem may happen in these two cases There is no USB driver installed You will find the driver on the CD If you connect the SenzaGate with your PC via USB Windows has to search for it automatically and sends a notification In this case you have to specify the driver path on the CD 2 The COM libraries of J ava are not installed It can be that you have your own J ava version installed or it is stored in another directory You can change the data manually in the javax comm properties and in win32com dll copying the data from the CD to the lib directory of your J ava installation 3 6 The application is not displayed in your browser 1 Please use the Internet Explorer 2 Make sure that if you do not use port 80 addresses you have to start with http e g http localhost 8080 WMSPortal app 3 Make sure that the proxy does not block local addresses if there is a proxy in use In Internet Explorer under Extras internet options gt connections gt Lan connections gt bypass proxy server for local addresses 4 Maybe you closed the ConfigurationUtility too fast and it had no time to restart the server Please start again the ConfigurationUtility and ping the Gate Wait till the message Parameters successfully saved comes Do not close the ConfigurationUtility before 5 Inthe Configuration Utility try to stop Tomcat server and to restart it 6 If you get following mess
33. s to the according COM port Save the configuration of the utility which will restart the Tomcat server Check the power supply battery status Did you change something in the hardware jumper position position of the SenzaBlocks related to the mother board is the antenna cable connected Is there a problem with range If there are large disturbances in the area it is possible that there are problems with the reception To test if the range is a problem put the Blocks closer together and test them again If you have started the application recently it can take some time until the values are displayed Restart the Tomcat server without the configuration Utility using start run enter services msc Stop the Tomcat server and reconnect the SenzaGate again and follow the instruction from the start of application Please restart your PC 3 2 If the blocks send the data too slow 1 The block cannot receive the complete configuration data Please configure the Block using the menu change Block It is possible that the value changed E Senza Technologies GmbH 35 von 39 0 Leveraging Power of Wireless User Manual SenzaWMS 3 3 Error messages Could not find file Parameters StarterKit Properties Probably application was not yet deployed 1 This behavior happens if the installation was not complete and the user pressed already the button finish at the installation The easiest way to correct
34. this is deinstall the SenzaMonitoring and install it again When you install again please take care that you give the system enough time to install all the applications thoroughly Let the Acrobat Reader open the manual then you can press the Finish button 2 It can happen that Tomcat can t deploy properly the war file In this case you can stop Tomcat from the Configuration Utility Then go in the Tomcat folder of your installation C Program Files SenzaApplications Tomcat apache tomcat 5 5 17 webapps or in C Program Files Apache Software Foundation Tomcat 6 0 webapps Delete there please only the folder WMSPortal There should be one file called wmsportal war Now you can start the Tomcat again from the config utility 3 4 The application creates problems after reinstalling a new J RE J ava runtime environment We recommend after the complete installation of the application that you do not install further J ava Updates If that was the case it can happen that the application will not run smoothly and the configuration utility informs you that there is no COM port found 1 There are certain files in the old RE folder which are installed together with SenzaWMS They are not located any more in the new JRE bin and lib folder They are javax comm properties ii win32com dll E Senza Technologies GmbH 36 von 39 0 Leveraging Power of Wireless User Manual SenzaWMS 3 5 If there is no com p
35. ture 1 Upper task bar 1 Closes the active tab Close the active display 2 Refresh the tab Automatic refresh is inbuilt with a cycle of 10 sec Yet if you wish to refresh faster then please press this button E Senza Technologies GmbH 10 von 39 Leveraging Power of Wireless User Manual SenzaWMS 3 SenzaGate status This button turns bluegrey if you have a connection to the SenzaGate A red button means that the connection to the SenzaGate is interrupted or the cable is not connected Please press the button to ensure if it is red or bluegrey 4 Send a time synchronized message to all SenzaBlocks This function allows the user to change the heartbeat and the power saving mode This menu item should not be abused since it is a delicate function applied for the whole network It allows the whole network to save more battery life and send scare data or use more battery power and dense the data cycles Networksettings Heartbeat 30 sec min x Sleepmode Ultra low power Power Saving Mode Low power Standard Picture 6 Timesync dialog In order to understand this setting imagine that the whole network is mostly in sleep Within this time nodes can t either send or receive any data The network then wakes up based on the heartbeat set in the network settings All the Blocks are up that time for a small time defined through the Power Saving Mode Ultra Low Power Low Power or Standard Standard mode is
36. unction you have to select the Blocks over the network menu here you can see if they are checked or crossed out 6 Send a data request to a SenzaBlock This function allows the user to send a data request to a SenzaBlock which runs outside the configured cycles Normally each Block sends his data in a store and upload cycle 7 About WMSPortal Information about your Software version E Senza Technologies GmbH 12 von 39 Leveraging Power of Wireless User Manual SenzaWMS 2 4 The accordion menu on the left The menu bar on the left consists out of following menu Netzwerke Diagramme Berichte Fouten Fouten Graph Routen Tabelle Routen l schen v 1 Network Network Status Show Data Assigning new Add a new Block Export Data Sensor Types Add new Sensor Type 2 Diagrams Graphs Livestats 3 Reports Alarmlist 4 Time planner Task List Add Task 5 Routing Routing Graph Routing Table E Senza Technologies GmbH 13 von 39 m Leveraging Power of Wireless User Manual SenzaWMS 2 5 Network 2 5 1 Network Status Block Name Last Health Time LQ Block 1 SB110 Mear OSC 8 10 07 3 59 04 PM 2 Block2 SB110 Gunjan room 6 10 07 3 59 29 PM 3 Bok3 SB110 Lars table ra 8 10 07 3 59 25 PM Block 4 SB120 Keltoum 6 10 07 3 59 21 PM E Block 5 SB120 Lars room a 8 10 07 3 58 01 PM block 6 Keltoum Table d 8 10 07 3 58 26 PM Block 7