Home

R&S ZN-Z152 Calibration Unit User Manual

image

Contents

1. R amp S ZN Z2152 Calibration Unit User Manual 6090 02 0 Test amp Measurement User Manual This User Manual describes the following R amp S ZN Z152 models e R amp S ZN Z2152 6 Port 1319 6003 36 2014 Rohde amp Schwarz GmbH amp Co KG Muhldorfstr 15 81671 Munchen Germany Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 E mail info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R amp S is a registered trademark of Rohde amp Schwarz GmbH amp Co KG Trade names are trademarks of the owners R amp S ZN Z152 is abbreviated as R amp S ZN Z152 Quality management and environmental management Sehr geehrter Kunde Sie haben sich fur den Kauf eines Rohde amp Schwarz Produk tes entschieden Sie erhalten damit ein nach modernsten Fer tigungsmethoden hergestelltes Produkt Es wurde nach den Regeln unserer Qualitats und Umweltmanagementsysteme entwickelt gefertigt und gepruft Rohde amp Schwarz ist unter ande rem nach den Managementsys temen ISO 9001 und ISO 14001 zertifiziert Der Umwelt verpflichtet 1 Energie effiziente RoHS konforme Produkte 1 Kontinuierliche Weiterentwicklung nachhaltiger Umweltkonzepte 1 ISO 14001 zertifiziertes Umweltmanagementsystem Dear customer You have decided to buy a Rohde amp Schwarz product This product has been manufactured using the most advanced meth ods It was
2. developed manufac tured and tested in compliance with our quality management and environmental manage ment systems Rohde amp Schwarz has been certified for exam ple according to the ISO 9001 and ISO 14001 management systems Environmental commitment 1 Energy efficient products 1 Continuous improvement in environmental sustainability 1 ISO 14001 certified environmental management system Certified Quality System ISO 9001 Certified Environmental System ISO 14001 Cher client Vous avez choisi d acheter un produit Rohde amp Schwarz Vous disposez donc d un produit fabriqu d apr s les m thodes les plus avanc es Le d velop pement la fabrication et les tests de ce produit ont t effec tu s selon nos syst mes de management de qualit et de management environnemental La soci t Rohde amp Schwarz a t homologu e entre autres conform ment aux syst mes de management ISO 9001 et ISO 14001 Engagement cologique 1 Produits a efficience nerg tique Am lioration continue de la durabilit environnementale Syst me de management environnemental certifi selon ISO 14001 1171 0200 11 V 05 01 1171020011 Customer Support Technical support where and when you need it For quick expert help with any Rohde amp Schwarz equipment contact one of our Customer Support Centers A team of highly qualified engineers provides telephone support and will work with yo
3. e automatic calibration for the selected number of ports using the Measurement Wizard or the Start Calibration menu R amp S ZVA B T analyzers or the Calibration Unit wizard R amp S ZNB C analyzers For details refer to your analyzer s help system 3 Remove the test cables from the unit connect your DUT instead and perform calibrated measurements 5 Accuracy Considerations To ensure an accurate calibration please observe the following items e No adaptors must be inserted between the calibration unit and the test ports e After connecting the unit to the USB port allow for a sufficient warm up time see data sheet before starting the calibration e To ensure best accuracy the analyzer automatically reduces the source power to 10 dBm If the test setup contains a large attenuation deactivate Auto matic Power Reduction for Calibration Unit in the Calibration tab of the Sys tem Configuration dialog and ensure an input power of 10 dBm at the ports of the calibration unit please also refer to the data sheet The calibration type depends on the number of ports and of the analyzer type If a single port is calibrated the analyzer uses a reflection calibration type e g Full One Port Refl OSM For 2 and more ports you can choose among several cali bration types User Manual 1319 6090 02 01 R amp S ZN Z152 User Characterization Automatic Calibration 6 User Characterization The calibration Unit off
4. ees 8 1 Safety Instructions This calibration unit has been designed and tested in accordance with the EC Certificate of Conformity and has left the manufacturer s plant in a condition fully complying with safety standards General safety considerations To maintain this condition and to secure safe operation you must observe all instructions and warnings given in this manual and in the user manual of the R amp S network analyzer IEN User Manual 1319 6090 02 01 3 R amp S ZN Z152 Safety Instructions USB Connection to the Analyzer 1 1 USB Connection to the Analyzer e The calibration unit is intended for direct connection to a network analyzer of the R amp S ZVA B T or R amp S ZNB C families following the procedure described on the following pages and in the analyzer s help systems e The length of the connecting USB cable should not exceed 3 m It is recom mended to use the cable delivered with the calibration unit e You can connect several calibration units to the different USB ports of the analyzer You can also connect cal units and other devices mouse USB memory stick etc simultaneously e An unused calibration unit may remain connected to the USB port while the network analyzer is performing measurements It must be disconnected dur ing a firmware update e tis safe to connect or disconnect the calibration unit while the network ana lyzer is operating Never connect or disconnect the unit while data is b
5. eing transferred between the analyzer and the unit Never connect the unit during a firmware update 1 2 ESD Protective Measures To protect the calibration unit against Electrostatic Discharge ESD damage use the wrist strap and grounding cord supplied with the network analyzer and con nect yourself to the GND connector at the front panel For details refer to the Quick Start Guide or Getting Started guide of your analyzer 1 3 RF Connection The maximum RF input power of the calibration unit is beyond the RF output power range of the analyzer so there is no risk of damage if the device is directly connected to the test ports If you use an external power amplifier make sure that the maximum RF input power of the calibration unit quoted in the data sheet is never exceeded IECH User Manual 1319 6090 02 01 4 R amp S ZN Z152 USB Connection to the Network Analyzer eS ee Automatic Calibration 1 4 Automatic Calibration A calibration unit is an integrated solution for automatic calibration of several net work analyzer ports The unit contains calibration standards that are electronically switched when a calibration is performed The calibration kit data for the internal standards is stored in the calibration unit so that the analyzer can calculate the error terms and apply the calibration without any further input Automatic calibration is generally faster and more secure than manual calibration e There is n
6. ers the possibility to store one or more user characteriza tion data on the internal flash memory or on the microSD card This can be done by using the function characterize cal unit For details refer to your analyzer s help system 7 microSD Card On the rear of the calibration unit there is a microSD card slot The microSD card can be used to store user characterization data The factory data is always stored on the internal memory It is recommended to use only the microSD card that is shipped with the calibration unit Before removing or inserting the card disconnect the USB connection of the calibration unit D Mounting the Calibration Unit To mount the calibration unit e g on a waver prober remove the elastic buffers on the bottom of the housing There are four threads for use of M2 5 screws IEN User Manual 1319 6090 02 01 8
7. o need to connect several standards manually The number of standards to be connected quickly increases with the number of ports e Invalid calibrations due to operator errors e g wrong standards or improper connections are almost excluded e No need to handle calibration kit data e The internal standards do not wear out because they are switched electroni Cally Scope of this document This User Manual gives a brief introduction to the unit s connection and use For detailed information refer to the help system of your network analyzer The R amp S ZN Z152 calibration units differ in the number of calibration ports and the connector types For an overview refer to the data sheet 2 USB Connection to the Network Ana lyzer The calibration unit provides the following connectors e A USB Type B connector at the rear used to power supply and control the unit A USB cable for connection to the network analyzer is provided with the calibration unit EE User Manual 1319 6090 02 01 5 R amp S ZN Z152 Function of the Status LED Automatic Calibration e Six RF connectors numbered 1 to 6 to be connected to the test ports of the analyzer The connector type is equal for all ports of type SMA f To connect the unit 1 Switch on and start up your network analyzer 2 Wear a grounded wrist strap see chapter 1 2 ESD Protective Measures on page 4 3 Connect the USB type A connector of the USB cable to any of the USB ty
8. pe A connectors on the front or rear panel of the analyzer You can also connect the unit before switching on the analyzer 4 Wait until the operating system has recognized and initialized the new hard ware After the initialization is completed the Status LED will switch to green 5 The unit is ready to be used as outlined below 3 Function of the Status LED The LED on top of the Calibration Unit informs about the actual status of the device The different states have the following meaning OFF The calibration unit is not connected or defective Red The micro controller is running but there is no USB communication with the network analyzer With an actual network analyzer firmware this status should only appear for a short time after connecting the calibration unit Green The calibration Unit is ready use Blinking orange Data transfer between the calibration unit and the network analyzer Do not disconnect the USB cable Blinking blue Calibration in progress IEN User Manual 1319 6090 02 01 6 R amp S ZN Z152 Performing an Automatic Calibration eR Automatic Calibration 4 Performing an Automatic Calibration After connection and initialization you can use the calibration unit as follows 1 Connect n analyzer ports n 1 to 6 depending on your analyzer and calibra tion unit model and the number of ports to be calibrated to n arbitrary ports of the calibration unit 2 Perform th
9. u to find a solution to your query on any aspect of the operation programming or applications of Rohde amp Schwarz equipment Up to date information and upgrades To keep your instrument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care that you will get the right information Europe Africa Middle East Phone 49 89 4129 12345 customersupport rohde schwarz com North America Phone 1 888 TEST RSA 1 888 837 8772 customer support rsa rohde schwarz com Latin America Phone 1 410 910 7988 customersupport la rohde schwarz com Asia Pacific Phone 6565 13 04 88 customersupport asia rohde schwarz com China Phone 86 800 810 8228 86 400 650 5896 customersupport china rohde schwarz com ROHDE amp SCHWARZ 1171 0200 22 06 00 R amp S ZN Z2152 Contents Contents 1 Safety INS NL iieecadesnrsienncivsncewesncnieneandeuusdvaieotbhinniensiwene 3 2 USB Connection to the Network AnalyZet ccccs 5 3 Function of the Status LED 0 cccceccecee eee eeeeeeeeeeeeeeeeeeeeees 6 4 Performing an Automatic Calbratton ee EEN 7 5 Accuracy Considerations ccccccccssseessseeeeeeeeeeseaeseeneeeees 7 6 User Characterization c ssesseesseeeeeeeeeeeeeeeeeeeeeeeeseeeeees 8 T le ERR G afdeed 8 8 Mounting the Calibration Uniit cccceeeeeeeseeeseeeeeeeeee

Download Pdf Manuals

image

Related Search

Related Contents

Samsung 940NW Užívateľská príručka  Delkin Devices PC585 User's Manual  3 - KellySolutions.com  Samsung E1120 Uživatelská přiručka  Philips GoGear Flash audio player  StarTech.com DisplayPort 1.2 cable with latches – certified, 10 ft  IPv6 Home Router Guideline (Translated Version)  Projektierungshandbuch FLX Series  SERVICE MANUAL  ATSメタルLSDサイレントタイプ:取扱説明書(PDF)  