Home

User Manual Fitvibexcel Pro Medical

image

Contents

1. Operating the Fitvibexcel Pro Medical using chip cards charged via the Fitvibexcel Pro Medical ITS Software The chip cards carry the data for self designed Fitvibexcel Pro Medical exercise or treatment programmes Use of the Fitvibexcel Pro Medical ITS software cards requires the easy Fitvibexcel Pro Medical ITS software to be installed on your computer and using the associated writer Please refer to the associated Fitvibexcel Pro Medical ITS Software user instructions for information on how to use the software Once the Fitvibexcel Pro Medical unit has read the Fitvibexcel Pro Medical amp ITS chip card you will be shown the Welcome page User manual Fitvibexcel Pro Medical 35 36 On the Welcome page you can choose whether to use the pre programmed training protocols on the chip card or to deduct time only in the free menu If your chip card has been charged with extra exercising time credits you will be taken straight to the main menu after having choosing Timecard Please refer to point 5 1 and 4 of this user manual for information on how to proceed from this point In addition to the other information the screen will also display the current exercise programme code the total number of exercise programmes stored on the Fitvibexcel Pro Medical ITS chip card and the name of the exercise programme It you select the pre programmed training protocols on the Welcome page you will be taken
2. 2 7 Connecting and switching on the Fitvibexcel Pro Medical Connect the hand held remote switch 22 to socket 21 The power input 18 is located on the right side of the electronic unit 30 You can now use the mains switch 19 to turn on the Fitvibexcel Pro Medical The unit can be used immediately after being switched on After switching on the device a screen mentioning the soft and hardware revision on the Fitvibexcel Pro Medical appears automatically followed by a settings menu From this menu one can modify the system settings consult the list of contra indications or continue to the main screen 14 User manual Fitvibexcel Pro Medical 2 8 2 8 1 2 8 2 System settings The Fitvibexcel Pro Medical vibration platform features a range of system settings that enable you to customize the unit s functions to meet your specific requirements We recommend using the Fitvibexcel Pro Medical default settings when using the unit for the first time and to customize settings afterwards The system settings menu can be accessed from the start menu The arrow buttons in the system settings menu are used to select from the various menu items The highlighted items show the activated settings Language selection This function is used to select your language You can set your specific language after selecting the language item from the system settings menu The following languages are available English Dutch German
3. Balance card 2 9 5 Upload data from Fitvibexcel Pro Medical ITS software 2 9 6 Reset default Settings 2 9 7 Statistics di Important information Si When not to use Contra indications Sie Indications ERES Important information before using the Fitvibexcel Pro Medical 3 4 Using the softmat 3 5 Your first Fitvibexcel Pro Medical Work Out 3 6 Stop exercising if you re A User manual Fitvibexcel Pro Medical ONNNO O 0 10 11 12 12 12 14 15 15 15 16 16 16 17 17 17 18 18 19 20 20 22 23 23 24 24 25 Application 4 1 4 2 4 5 4 4 General 26 Exercise on the Fitvibexcel Pro Medical 4 2 1 General operations 4 2 2 Start Stop button Using the hand and foot straps Vibration training parameters 4 4 1 Main Screen 4 4 2 Free parameters 4 4 3 Indications 4 4 4 Training per muscle group 4 4 5 Exercise list 4 4 6 Exercise 4 4 7 Active Time and Rest Time 4 4 8 Increasing your exercise load Operating dy m 5 2 59 3 Operating the Fitvibexcel Pro Medical using Chip Cards Operating the Fitvibexcel Pro Medical using Timecards Operating the Fitvibexcel Pro Medical using chip cards charged via the ITS Software Errors guarantee maintenance and cleaning decommissioning 6 1 Ou 6 3 6 4 65 6 6 Errors Guarantee 6 2 1 Terms of guarantee 6 2 2 Limitation of the manufacturer s liability Service Maintenance Cleaning Decommissi
4. Hand straps 1 pair Remote control e Soft mat Exercise poster Technical specifications e Weight 120 kg Dimensions 1050 x 990 x 1440 mm Maximal static load 250 kg dynamic proportions 20 Noise level max 71 dBa Standard colour grey white black 42 User manual Fitvibexcel Pro Medical e Supply voltage 230V 10 50 60Hz 115V 10 50 60Hz External fuses 10AT local electric installation Miniature fuses T2AL for 230V T4AH for 115V Power consumption max 420 VA Protective system e Type of protection Type B Degree of protection IP20 e Transport and storage conditions In the manufacturers package at following limits 20 C to 60 C 5 to 100 humidity including condensation 500 hPa to 1060 hPa atmospheric pressure e Operating condition 10 C to 40 C ambient temperature 5 90 air humidity non condensing This medical device complies with the applicable standards EN 60601 1 1 a IEC 60601 1 and EN 60601 1 2 IEC 60601 1 2 and with Medical Device Directive MDD 93 42 EEC Classification in accordance with MDD is lla User manual Fitvibexcel Pro Medical de o References to the electro magnetic comptability requirements EMC The Fitvibexcel Pro Medical conforms to all of the relevant EMC directive and standard EN 60601 1 2 IEC 60601 1 2 requirements when used in conjunction with the accessories recommended by the manufacturer Please read and o
5. ITS Software User manual Fitvibexcel Pro Medical 29 4 4 4 Training per muscle group When choosing the program training a muscle group in the first screen one has to scroll until the wished muscle group is reached By clicking NEXT the following screen will be displayed A user can Make a choice of level with the left side buttons Make a choice of week with the right side buttons Information about the number of exercises exercise time and total time is shown at the bottom of the display When clicking the button NEXT the training protocol will be displayed as shown below in the chosen configuration An overview shows how many exercises will have to be performed in the given training menu 30 User manual Fitvibexcel Pro Medical 4 4 5 4 4 6 Exercise list In this menu a user can scroll until the wished exercise is reached When the button is clicked the exercise will be loaded In this menu all training parameters can be modified To start the exercise click on the Start Stop button Click on the button to go L back to the exercise list Exercise By clicking on the Start Stop button in the exercise list a full colour high resolution 3 D image that is visually self explanatory show users clearly how to assume the correct training postures on the Fitvibexcel Pro Medical additional explanations can also be viewed Once your training starts the ani
6. Spanish French Italian Norwegian Polish Russian Swedish Turkish and Portuguese Key beep tone This function is used to turn the beep tone that is sounded when a button is pressed on and off User manual Fitvibexcel Pro Medical 15 2 8 3 Volume This is where you can adjust the volume of the key beep tone 2 8 4 Rest Time end beep This is where you can turn the acoustic signal marking the end of the Rest Time on and off 2 8 5 Colours display Via the field colours display one can switch the background colour of the software as being displayed on screen 16 User manual Fitvibexcel Pro Medical 2 9 2 9 1 a Device settings Accessing the device settings menu The device settings menu can be accessed by inserting the configuration card in the card slot of the Fitvibexcel Pro Medical Via the button Next all time parameters are highlighted one after each other These parameters can be modified with the up and down arrows at the right side Furthermore one can modify the time notification towards US or European standards and allowing an automatic Summer time setting Start Screen With this function a user can modify the sequence of the screens depending the way the device is being used in his centre This function is active from software version 3 01 only User manual Fitvibexcel Pro Medical 247 3 2 9 3 Fine tuning frequency In order to avoid resonance in buildings
7. Timecards A timecard limits the time that the Fitvibexcel Pro Medical vibrates in accordance with the time credits minutes available on the chip card Example If a Fitvibexcel Pro Medical chip card has a credit of 30 minutes of vibration training time you can exercise on the unit for a total of 30 minutes of vibration training time e any Rest Times are not charged to the card The exercise time credits on the card can also be used on different days When the time credits minutes on 34 User manual Fitvibexcel Pro Medical 5 3 the Fitvibexcel Pro Medical chip card have been used up the card s credits can be topped up by using the card top up unit The Fitvibexcel Pro Medical can still be operated even if the time credits available on the chip card are insufficient for a particular series of exercises Should this be the case the unit will continue to operate and vibrate until the available time credits have been used up The Fitvibexcel Pro Medical chip card can be charged with a maximum of 999 minutes of exercise time credits Please refer to the card top up unit s user instructions for more information on how to operate the device Once the Timecard has been read by the Fitvibexcel Pro Medical unit it will open the Main screen page From this point onwards Fitvibexcel Pro Medical s that have their card readers enabled are operated in the same way as Fitvibexcel Pro Medical whose card readers are disabled see point 4
8. land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m 48 User manual Fitvibexcel Pro Medical Recommended separation distances between portable and mobile RF communications equipment and the Fitvibexcel Pro Medical The Fitvibexcel Pro Medical is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Fitvibexcel Pro Medical can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the Fitvibexcel Pro Medical as recommended below according to the maximum output power of the communications equipment Separation distance according to frequency of transmitter m Rated maximum 150 kHz to 80 80 MHz to 800 MHz 800 MHz to 2 5 output power of MHz d 429vVP GHz transmitter W d 1 2VP d 2 3vP 0 01 0 12 0 12 0 23 0 1 0 38 0 73 1 1 2 dod 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equat
9. straight to the diagram showing the first exercise You can now start the vibration plate by pressing the START STOP button You can skip exercises by using the NEXT 14 button and you can go back to those exercises using the BACK 8 button It is not possible to return to a skipped exercise once you have started on the next one Example the exercise programme you have selected contains 6 individual exercises You completed the first of those 6 exercises skipped the second and third and are now starting on the fourth this means that you cannot now return to the second and third exercise If you accidentally skipped the last of a series of exercises you will be shown the End of Exercise Programme page User manual Fitvibexcel Pro Medical Once you have removed the chip card from the card reader you will always be taken back to the Welcome page When re inserting the chip card you can continue your training programme by either starting on the next exercise programme or the next exercise of an exercise programme that you haven t yet finished Following completion of all exercises it is not possible to continue using the chip card without re programming it unless the card was issued without any time limits in which case it can be used for an infinite number of times User manual Fitvibexcel Pro Medical a 6 1 6 2 6 2 1 a Errors guarantee maintenance and cleaning decommissioni
10. to IEC 60601 2 36 this doesn t comply during the generation and release of shockwaves The Fitvibexcel Pro Medical is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes User manual Fitvibexcel Pro Medical 45 46 Guidance and manufacturer s declaration electromagnetic immunity The model Fitvibexcel Pro Medical is intended to use in the electromagnetic environment specified below The customer or the user of the Fitvibexcel Pro Medical should assure that it is used in such an environment Immunity test Electrostatic discharge ESD IEC 61000 4 2 Electrical fast transient Bursts IEC 61000 4 4 IEC 60601 test level 6kV contact 8kV air 2kV for power supply lines 1kV for input output lines Compliance level 6kV contact 8kV air 2kV for power supply lines 1kV for input output lines Electromagnetic environment guidance Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 1 1 1kV lin
11. Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 IEC 60601 test level 3Vrms 150 kHz to 80 MHz 3 V m 80 MHz to 2 5 GHz Cmpliance level 3 Vrms 150 kHz to 80 MHz 3 V m 80 MHz to 2 5 GHz Electromagnetic environment guidance Portable and mobile RF equipment should be used no closer to any part of the Fitvibexcel Pro Medical including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance d 1 2 P d 1 2 P 80 MHz to 800 MHz d 2 31P 800 MHz to 2 5 GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol User manual Fitvibexcel Pro Medical E by e NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and
12. Fitvibexcel Pro Medical has the possibility in an up or downwards shift of 3Hz 2 9 4 Balance card By enabling the balance card Fitvibexcel Pro Medical will only be accessible when inserting a valid Fitvibexcel Pro Medical card in the card slot see also the user manual of Fitvibexcel Pro Medical ITS software 18 User manual Fitvibexcel Pro Medical 2 9 5 Upload data from Fitvibexcel Pro Medical ITS software Via an USB connection it is possible transferring data from Fitvibexcel Pro Medical ITS to the device software Via this menu it is possible to integrate new exercises in the Fitvibexcel Pro Medical database to change the trainer or to manage the indications menu in the device software Select the data to be modified exercises trainer or indications Unsert a by Fitvibexcel Pro Medical ITS software programmed USB stick in the right USB slot looking from the backside e Select Set e Wait until a message appears indicating that the USB stick may be removed Restart the Fitvibexcel Pro Medical Please notice that uploading data from Fitvibexcel Pro Medical E ITS software is only possible with a modified version of Fitvibexcel Pro Medical Software This function is active from software version 3 01 only User manual Fitvibexcel Pro Medical 19 2 9 6 Reset default Settings This function is active from Fitvibexcel Pro Medical software version 2 16 only With the optiona
13. Screen The operating system is clear and self explanatory In the main screen a user can make a choice out of four options Free parameters Start training immediately and enter your own parameters Indications Select the indication and enter your level 3D exercise dynamic pictures will guide you through the training protocol Training per muscle group Select the zone of your body you want to strengthen up 3D exercise dynamic pictures will guide you through the protocol Exercise list Choose an exercise from a list and start your training All options are made via the up and down buttons followed by START STOP 28 User manual Fitvibexcel Pro Medical 4 4 2 4 4 3 Free parameters A user can Change the amplitude between low and high also during training or treatment Modify the frequency between 20 and 60 Hz in steps of 5 Hz Change the running time between O and 180 seconds Indications A user can Make a choice of indication with the left side buttons Make a choice of level with the right side buttons Information about the number of exercises exercise time and total time is shown at the bottom of the display When clicking the button NEXT the protocol will be displayed as shown in the below chosen configuration The items listed in this screen are manageable via the optional Fitvibexcel Pro Medical ITS Software See also Upload data from the Fitvibexcel Pro Medical amp
14. accessories Fitvibexcel Pro Medical Software Fitvibexcel Pro 337612 Medical ball Fitvibexcel Pro integrated training system software F Medical push up bars 337634 Fitvibexcel Pro 337656 Medical comfort cushion Fitvibexcel Pro Medical back 337645 cushion Fitvibexcel Pro 337623 ja Medical straps User manual Fitvibexcel Pro Medical 2 3 Description of the control buttons and accessories The numerals used in the list below correspond to those used in the diagram 1 a 3 4 5 6 7 8 B Vibrating platform Foot strap Foot switch start stop Handlebar Hand strap Control panel display Start Stop button Button Button 10 Button 11 Display 12 Button 19 Button 14 Button 15 Card slot 16 Cushion Optional 17 Mat 18 Mains cable 19 Mains switch 20 Attachment point for arm or foot strap 21 Connection socket for hand held remote switch 22 Hand held remote switch with Start Stop button User manual Fitvibexcel Pro Medical zx 2 4 2 5 2 6 S402 Inspection Please check the Fitvibexcel Pro Medical and accessories upon delivery for any potential damage sustained during transport and whether all of the accessories have been supplied See section 2 1 Please notify you supplier immediately in the event of transport damage or missing items Do not use the Fitvibexcel Pro Medical if damaged In Case of condensation wait for set in operation up to the unit is ada
15. ad from an intermediate towards an advanced program as followed 1 Taking out the balance of the basic exercises 2 Changing the planes of motion of basic exercises into new movements 32 User manual Fitvibexcel Pro Medical User manual Fitvibexcel Pro Medical 299s 5 1 5 2 Operating Operating the Fitvibexcel Pro Medical using Chip Cards See device settings point 2 9 4 balance card must be ON The chip card reader 15 is located right below the control unit 11 Insert the chip card into the reader 1 5 until it clicks into place The chip should be located on the top of the Fitvibexcel Pro Medical chip card The chip card reader accepts different types of chip cards e the chip card which is used in conjunction with the Fitvibexcel Pro Medical ITS software and stores all the data relevant to a user e The Timecard which is only used to limit the Active Vibration Time of the Fitvibexcel Pro Medical in accordance with the credit minutes available on the card The chip card reader recognizes the different types of cards and selects the corresponding operating software automatically The Insert Card screen can display different types of error messages e Chip card inserted incorrectly insert card correctly see above Card validity expired change card validity in the Fitvibexcel Pro Medical ITS software No training on card Operating the Fitvibexcel Pro Medical using
16. bserve the information relating to the EMC in the user instructions and in this and any other accompanying documents before installing and using the Fitvibexcel Pro Medical You have acquired a device that was developed and produced in accordance with the latest technological advances in conformity with the above EMC directive Fitvibexcel Pro Medical is protected against interference and does not interfere with other electrical devices in accordance with the standards it complies with Type of protection against electric shocks class 1 Degree of protection against electric shocks lt lt gt 44 User manual Fitvibexcel Pro Medical EMC guidance and manufacturer s declaration Guidance and manufacturer s declaration electromagnetic emissions The model Fitvibexcel Pro Medical is intended to use in the electromagnetic environment specified below The customer or the user of the Fitvibexcel Pro Medical should assure that it is used in such an environment Emissions test RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000 3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 Compliance Group 1 Class B Class A Complies Electromagnetic environment guidance The Fitvibexcel Pro Medical uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment According
17. cal 4 2 2 4 3 Start Stop button The Fitvibexcel Pro Medical is equipped with 3 start stop buttons that can be used to start and stop the vibration mechanism at any time e An orange coloured start stop button 15 located in the centre on the control panel beneath the display e A foot operated start stop switch 3 located on the handlebar at the same level as the vibrating platform e A hand held remote switch 18 which is connected to the control panel by a cable You can use any of these buttons to start and stop the vibration mechanism from any posture and position Using the hand and foot straps The straps are used to transfer the vibration to specific parts of the body such as the hamstrings as shown in the illustration When using straps the vibrations are transmitted to the relevant parts of the body via the non elastic strap material Depending on the particular exercise the straps can be fastened to any of the fixation point 20 on the vibration platform The straps have differently coloured reference lines enabling a correct adjustment and an easier match of their lengths User manual Fitvibexcel Pro Medical 27 4 4 4 4 1 Vibration training parameters e Vibration frequency 20 60 Hz e Intensity Amplitude high low e Active Time 0 180 sec Rest Time 0 180 sec e Exercise type static dynamic Dynamic exercises are shown dynamically or indicated with an arrow Main
18. e relevant EMC directive and standard EN 60601 1 2 IEC 60601 1 2 requirements when used in conjunction with the accessories recommended by the manufacturer This device User manual Fitvibexcel Pro Medical xm complies with the applicable standard EN 60601 1 IEC 60601 1 Furthermore the notified body TUV Rheinland LGA Products GmbH also Carries out checks regularly This ensures that you are working with equipment that meets all the requirements and provides you and your clients the best possible level of safety Please refer to section 6 ERRORS WARRANTY MANTENANCE AND CLEANING for information on the manufacturers liability 8 User manual Fitvibexcel Pro Medical 1 7 Description of used marks and symbols Applied part type B 01 97 CE mark with registration number of the C C notified body SN Serial Number Article Number REF Main Fuse Year of manufacturing 2009 pan Manufacturer Do not dispose this electrical equipment with general house hold waste N General warning sign ISO 7010 W001 User manual Fitvibexcel Pro Medical 9 2 1 2 2 s Components and Assembly Components and standard accessories e Vibrating platform with power cable 300240 e Soft mat o Hand held remote switch Pair of foot straps 1 pair of hand straps Pair of hand straps P e 300235 e Assembly tools y User manual 1 soft mat 327712 FEFE T 1 poster 300234 ATEN with exercises te ER E Optional
19. e s to line s 2kV line s to earth E99 LJ gt 95 dip in for 0 5 cycle 40 U 6096 T in U for 5 cycles 70 96 U 30 dip in U for 25 cycles 1kV line s to line s 2kV line s to earth lt 5 U gt 95 96 dip in U for 0 5 cycle 40 96 U 60 96 dip in U for 5 cycles 70 96 U 30 96 dip in U for 25 cycles Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of the Fitvibexcel Pro Medical requires continued operation during power mains interruptions it is recommended that the Fitvibexcel 5 751 lt 5 96 U Pro Medical be 95 96 dip in gt 95 96 dip in U powered from an U for5s for5s uninterruptible power supply or a battery Power frequency 3 A m 3 A m 50 60 Hz magnetic field IEC 61000 4 8 The power frequency magnetic field should be that of a typical commercial or hospital environment NOTE U is the a c mains voltage prior to application of the test level User manual Fitvibexcel Pro Medical Guidance and manufacturer s declaration electromagnetic immunity The model Fitvibexcel Pro Medical is intended to use in the electromagnetic environment specified below The customer or the user of the Fitvibexcel Pro Medical should assure that it is used in such an environment Immunity test
20. fitvibe User Manual Fitvibexcel Pro Medical Art nr 328 882 Copyright Uniphy Elektromedizin GmbH amp CO KG 2008 Fitvibexcel Pro Medical is a registered trademark of Uniphy Elektromedizin GmbH amp Co KG 2008 Unauthorised reproduction either in whole or part of the software provided with this product is strictly prohibited and is subject to prosecution All rights reserved uud Elektromedizin GmbH amp Co KG Neuendorfstrasse 19b D 16761 Hennigsdorf Germany www Fitvibe com Item code 54005311 Gebrauchsanleitung Fitvibexcel Pro Medical 11 05 2011 User manual Fitvibexcel Pro Medical V1 1 08 2013 C C 01 O7 Table of Content 1 Safety ted Electrical safety 12 Explosion protection 1 3 Product safety 1 4 Environmental conditions for transport and storage 1 5 Using the Fitvibexcel Pro Medical 1 6 Conformity 1 7 Description of used marks and symbols 2 Components amp assembly 2 1 Components and standard accessories 2 2 Optional accessories 23 Description of the control buttons and accessories 2 4 Inspection 2 5 Mains voltage 2 0 Removing the transportation lock and fitting the handlebar 2 Connecting and switching on the Fitvibexcel Pro Medical 2 8 System settings 2 8 1 Language selection 2 8 2 Key beep tone 2 8 3 Volume 2 8 4 Rest Time end beep 2 8 5 Colours display 2 9 Device settings 2 9 1 Accessing the device settings menu 2 9 2 Start Screen 2 9 3 Fine tuning frequency 2 9 4
21. ing so the following areas need particular attention Check all screws and mechanical clamp joints Visually check all cables and their connectors Check the functioning of the hand held remote and foot switch Check the rubber springs for signs of mechanical damage Check the rubber O ring inside the motors Cleaning The vibrating platform control unit and all accessories can be cleaned using a damp cloth Only use mild non abrasive cleaning agents The handlebar can be cleaned using a standard surface disinfectant Decommissioning and disposal When you wish to dispose your Fitvibexcel Pro Medical unit you can follow two ways You can bring the unit and its accessories to a disposal company that specialises in electronic products or that has means of forwarding the unit to such a company If you live in a country where suppliers are legally obliged to dispose of their products you can return the unit to your local supplier Due to the type of plastic and electronic components they contain most countries prohibit disposal of these kinds of units as ordinary household waste For the event that you chose to dispose of the unit yourself or are accepting responsibility for its disposal we would like to provide you with the following environmental information 40 User manual Fitvibexcel Pro Medical The components of the Fitvibexcel Pro Medical vibration platform can be divided into three categories The vibration platform contr
22. ion applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people User manual Fitvibexcel Pro Medical 49 50 User manual Fitvibexcel Pro Medical User manual Fitvibexcel Pro Medical 51 Fitvibexcel Pro Medical Pasweg 6a e 3740 Bilzen e Belgium Fitvibexcel Pro Medical is a division of GymnaUniphy NV
23. l Fitvibexcel Pro Medical amp software it is possible to modify the indications or insert new training programs With resetting all modifications data will be reset to the default device settings 2 9 7 Statistics In the statistics Fitvibexcel Pro Medical software menu a Fitvibexcel Pro Medical owner can consult the counter working hours of the Fitvibexcel Pro Medical the total time Fitvibexcel Pro Medical has vibrated divided in the different operation modes This function is active from software version 3 01 only 20 Usermanual Fitvibexcel Pro Medical User manual Fitvibexcel Pro Medical 21 3 1 Do Important information When not to use Contra indications It iS important to make sure that users of the Fitvibexcel Pro Medical vibration platforms do not and are not likely to be suffering from any of the contra indications listed below before allowing them to commence training Any person suffering or likely to suffer from any of the contra indications listed below must not use the vibration platform Always consult a medical expert your GP a consultant or the Fitvibexcel Pro Medical amp instructor in case of doubt The list of contra indications is accessible from the first screen Contra initio d piia E A PO Wu O ONE SG pa AA SOR Sr a osi og E ES ri ee RT Ps d a A a ram a ar RE Series G 700 ib ren th dac amc m gt et Absolute contra indications Relative con
24. le for possible follow up damages injuries at therapists instructors users or the equipment used which are caused by wrong diagnosis improper use of device and or accessories misinterpretation or non compliance with this user manual poor maintenance of the unit or when the unit was maintained by persons that were not authorized by the manufacturer for that purpose Service e All repairs modifications and upgrades must be performed implemented by authorised personnel only e The electrical wiring of the space in which the unit is set up must comply with the relevant legal regulations e The unit must only be used for its intended purpose e The unit must be serviced regularly and in accordance with the relevant instructions e The legal regulations regarding the use of the unit must be observed at all times Uniphy Elektromedizin GmbH amp Co KG and its representatives shall not be held responsible for damage injuries faults or malfunctions caused as a result of improper use or failure to observe maintenance instructions Servicing and warranties are provided by your supplier The warranty becormes void if the unit is not used in accordance with the above instructions Should you have any further questions or require additional information please feel frre to contact your dealer User manual Fitvibexcel Pro Medical 39 6 4 6 5 Maintenance It is recommended that a specialist services the unit annually When do
25. mated 3 D images display the precise sequence of positions for maximum gain At the bottom screen a muscle man shows the trained muscle group Start the exercise by clicking the Start Stop button again Click on the button to go back to the exercise list At the bottom frame one can consult the training parameters for the given exercise When working with the pre programmed protocols these data are not changeable User manual Fitvibexcel Pro Medical ea o 4 4 7 4 4 8 Active Time and Rest Time When using the default training protocols while the vibration is on the active time is shown on the display and being counted down automatically to O sec Once the active time is finished the vibration mechanism stops the next exercise is displayed and the rest time is being counted down Once the Rest Time has elapsed the vibration can be started again using the START STOP button The Rest Time can be skipped by pushing the START STOP button Once the last exercise has been completed a picture shows end of exercise Increasing your exercise load Increasing the load of your training program can be done with vibration training in the following steps Creating overload within a basic program exercises towards an intermediate program as followed 1 Increasing the duration of the exercises Time 2 Increasing the frequency of the exercises Hz 3 Increasing the amplitude of the exercises Low High Creating overlo
26. ng Errors e THE UNIT CANNOT BE SWITCHED ON Check whether the mains power is on the mains switch is turned On and whether the power cable and the fuses are OK You can replace any faulty fuses yourself Please only use fuses of the type stated on the unit s rating plate Replacement fuses can be ordered from your supplier THE DISPLAY SHOWS MESSAGES IN A FOREIGN LANGUAGE Go to the system settings menu and select the required language Please get in touch with your supplier should this error continue to occur NONE OF THE CONTROL ELEMENTS WORK Turn off the unit and turn it on again Please get in touch with your supplier should this error continue to occur Guarantee Terms of guarantee Guarantee period of the Fitvibexcel Pro Medical is 24 months and begins at the date of purchase the proof is the date on the invoice This guarantee includes all defects of materials and production quality The guarantee applies only for using the unit according to the intended purpose and observing the instructions for use The guarantee does not apply for cases of poor maintenance wrong implementation of an error and when maintenance and or repair work was performed by persons who were not authorized by the GymnaUniphy Company and of course for accidents and damages caused by the above mentioned cases 38 User manual Fitvibexcel Pro Medical 6 2 2 6 3 Limitation of the manufacturer s liability The manufacturer is not liab
27. nsport and storage While packaged the Fitvibexcel Pro Medical can be transported and stored for a maximum of 15 weeks under the following conditions Temperature range 20 C to 60 C Relative humidity 10 100 including condensation please allow device adjust to local temperature before switsching it on Atmospheric pressure 500 hPa 1060 hPa Using the Fitvibexcel Pro Medical The unit must only be operated by authorised personnel Before you start using the Fitvibexcel Pro Medical for the first time please make sure you have read and understood all information provided in this User Manual Familiarity with the information and instructions contained in this manual is an essential requirement to ensure efficient and optimal use of the system to avoid dangers to persons and to the equipment and to obtain good results The Fitvibexcel Pro Medical vibration platform is designed solely for vibration training and or treatment The Fitvibexcel Pro Medical can be operated at ambient temperatures of 10 C to 40 C Conformity The Fitvibexcel Pro Medical has been developed and is produced tested and sold according to the international quality management standards EN ISO 9001 and EN ISO 13485 Furthermore the Fitvibexcel Pro Medical meets the strict requirements of European Medical Device Directive 93 42 EWD as indicated by the presence of a CE mark CEO197 on the apparatus The Fitvibexcel Pro Medical conforms to all of th
28. o BPPV Venous insufficiency with ulcus cruris Morbus Sudeck Stadium II CRPS Lymphatic edema 3 2 Indications Postnatal training e Osteoporoses Proprioception Lower back pain Blood circulation e Cellulite e Weight loss 3 3 Important information before using the Fitvibexcel Pro Medical e Always make sure that you users do not suffer or are likely to suffer from any of the contra indications listed under 3 1 before commencing training e Always wear sport shoes with flexible rubber soles e The first training session must be supervised by an instructor See section 3 4 Your first Fitvibexcel Pro Medical workout e Closely follow the instructions on the postures to assume on the unit on how to carry out the exercises and follow the recommended Rest Times This will ensure that you get the most out of your training session and will protect you from injuring yourself User manual Fitvibexcel Pro Medical 3 4 3 5 CDA Drink an isotonic sports drink or some water approx 1 2 1 hour before your training session The Fitvibexcel Pro Medical vibration platform has been pre programmed with a training programme specifically designed to gradually get used to exercising on the unit You may change your exercise programmes following consultation with your Fitvibexcel Pro Medical instructor Using the softmat When doing exercises which involve resting on the platform wi
29. ol panel cables straps and soft cover mat are classed as electronic or non hazardous chemical waste Amongst other things these components contain lead tin copper iron and various other metals and types of plastic In most countries this type of waste is classed as non hazardous chemical waste and must be disposed of in accordance with the relevant local regulations Packaging materials and manuals are recyclable and can be disposed of at recycling centres of as household waste depending on local waste disposal regulations The information supplied above also applies to the unit s accessories The device complies with the essential requirements of the Waste Electrical and Electronic Equipment WEEE directive 2003 1 08 EC of the European parliament and of the oncil as most recently changed User manual Fitvibexcel Pro Medical zu 7 Technical Data Vibration plate e Vertical vibration amplitude 1 5 amp 3 mm Ergonomic handle e Start stop on plate Extra large exercise surface Frequency 20 eoHz adjustable per 5Hz 5 Fixation points for straps Handle Integrated card reader Electronics insulated from vibration e Start stop on display Start stop by remote control Software e Quick start Dynamic 3 D pictures e Colour screen Integrated training software Indication amp contra indication list e Training amp Time card feature Standard accessories Foot straps 1 pair
30. oning and disposal Technical data References to the electromagnetic comptability requirements EMC User manual Fitvibexcel Pro Medical 26 26 27 27 28 28 29 29 31 32 32 33 33 34 34 35 38 38 38 39 39 40 40 40 42 44 1 Safety CAUTION Before you start using the Fitvibexcel Pro Medical for the first time please make sure you have read and understood all information provided in this operating manual 1 1 Electrical safety The Fitvibexcel Pro Medical must only be used in spaces and facilities that comply with the relevant legal regulations The unit must be fitted with a safety plug 1 2 Explosion protection The unit is not suitable for use in spaces that contain flammable gasses or vapours 1 3 Product safety e Persons suffering or likely to be suffering from one or more of the contra indications listed under the section Do not use if in the start menu may only use the Fitvibexcel Pro Medical following consultation with a medical specialist Section 3 1 of this User Manual contains a comprehensive list of all contra indications Every person using the Fitvibexcel Pro Medical must check whether any of the listed contra indications apply of could apply to them see 3 1 e The unit is not suitable for use in damp spaces e Please keep this User Manual in close proximity to the unit 6 User manual Fitvibexcel Pro Medical 1 4 1 5 1 6 Environmental conditions for tra
31. pted to the room temperature Mains voltage The Fitvibexcel Pro Medical is suitable for use with a mains voltage of either 230V 50 60Hz or 115V 50 60Hz Check whether the mains voltage in your area matches the unit s voltage as stated on the label on the rear of the control panel any voltage higher than that stated can cause irreversible damage to the machine Removing the transportation lock and fitting the handlebar The transportation lock inside the electronic unit 30 must be removed before starting up the Fitvibexcel Pro Medical To do so remove the screws 34 on the base plate 33 of the electronic unit 30 and pull the metal transportation lock 31 out of the unit figure 2 31 32 User manual Fitvibexcel Pro Medical The handlebar can only be fitted to the base of the vibration platform once the metal transportation lock has been removed see figure 3 The electronic unit 30 is fitted onto the base plate of the vibrating unit 1 by using the open end wrench 48 hexagon head screws 44 spring washers 43 and washers 42 The electronic unit and the vibrating platform are connected to one another using the plug 40 and socket 41 Insert the plug into the socket and secure the connection using the coupling ring of the plug The two covers 47 and 49 are now fitted over the openings on the electronic unit 30 using the screws 46 and washers 45 figure 3 User manual Fitvibexcel Pro Medical 13
32. th parts of your body e g your hands feet or bottom you need to place the softmat supplied with the Fitvibexcel Pro Medical on top of the vibrating platform Your first Fitvibexcel Pro Medical Work Out Before using the Fitvibexcel Pro Medical actively a first introduction must have taken place to adapt to and get used to the vibrations One way to create this adaption is by following next steps B 2 3 In the Main screen select Free parameter Set the following intensity 40Hz Low Amplitude 30 sec Put one foot on the platform wearing sport shoes with no mat on the platform or no sport shoes with a mat on the platform Lift your heel from the platform putting the tension on your calves always make sure that the muscle you want to train is under pretension Press the start button Repeat this procedure with the other foot User manual Fitvibexcel Pro Medical 3 6 With any position standing on the vibration platform make sure about the following points before pressing the start button Make sure the tension leaning is on the front of you feet not on your heels No locked or overstretched body parts joints amp ligaments Muscles must be pretensioned Pretension is necessary to have the muscles absorb the vibrations e That the position of the head is levelled These steps will make sure that the training or treatment will be comfortable Stop exercising if you re Feeling diz
33. tra indications use Fitvibexcel Pro Medical only after con sulting a medical doctor Acute inflammations infections and or fever Epilepsy Acute arthropathy and arthrosis Gallstones kidney stones bladder stones Acute rheumatoid arthritis Articular rheumatism and arthrosis Acute headache Postoperative wounds Heart failure insufficiency NYHA III IV Cardiac dysrhythmia Implants Endoprotheses Cardiac affections Metal or synthetic implants e g pacemaker artificial cardiac valves recent stents Metal or plastic implants piercing or gyne cologic implants Acute thromboses or increased thrombotic afflictions 6 months Chronic back pain 6 months after acute appearing Acute back problems Severe diabetic mellitus with arterial circu lation disorders User manual Fitvibexcel Pro Medical Absolute contra indications Relative contra indications Pregnancy Tumors in a period 5 years plus after appearing excluding metastases in the musculoskeletal system Severe osteoporosis with BMD 70mg ml Spondylolisthesis without gliding Spasticity M Parkinson Morbus Sudeck Stadium I CRPS I Chondromalasy of the joints of the lower extremities osteonecrosis and chondrosis Tumors with metastases in the musculoskel etal system Arterial circulation disorders Stadium Fontaine III9 Benign Paroxysmal Positional Vertig
34. zy Experiencing pain Feeling unwell tense or nauseous User manual Fitvibexcel Pro Medical J5 4 1 4 2 4 2 1 a Application General The Fitvibexcel Pro Medical vibration platform generates three dimensional mechanical vibrations with its main vector being vertical The Fitvibexcel Pro Medical is extremely easy to use and its Operation is based on clear and logical principles You can use the unit as soon as you have familiarized yourself with the various buttons and their functions The Fitvibexcel Pro Medical has been pre programmed with exercise routines both in an indication menu as in the menu training per muscle group You can however also specify your own exercise parameters using the Free parameters menu or the exercise list This chapter will guide you through all of the options available lf the Card reader in your Fitvibexcel Pro Medical has been enabled See above these menus will only be accessible when a valid by Fitvibexcel Pro Medical ITS software programmed card is inserted in the card lock Please see point 5 for more information on Fitvibexcel Pro Medical ITS software Exercise on the Fitvibexcel Pro Medical General operations The Fitvibexcel Pro Medical vibration platform is operated using the 6 selector buttons and START STOP button on the control panel The arrows on the display explain the function of the corresponding button 26 User manual Fitvibexcel Pro Medi