Home

User Manual MainsPowered THELIGHT June11

image

Contents

1. The total or partial reproduction of this guide is prohibited without the express written permission of THELIGHT THELIGHT technology is protected under Spanish license laws with international patents pending Information and specifications in this document are subject to change without notice 2011 Copyright THELIGHT All rights reserved SAFETY PRECAUTIONS Various symbols are used throughout this instruction manual and on the product to prevent physical harm to you or other people and damage to property The symbols and their meanings are explained below AN Warning Possible risk of injury or damage to equipment Danaer This symbol indicates the risk of electric shock or fire danger that could g result in injury or damage to equipment This equipment has been checked and meets the requirements of general safety for electronic devices These requirements are specified to provide a reasonable protection against electromagnetic interferences when the equipment is used in commercial environments This equipment generates uses and can emit waves of radio frequency and if not properly used following the instructions of this manual can produce interferences in radio communications The use of this equipment in residential areas can produce interference the user will be the only responsible of correcting them CAUTION Though the light generated by LED does not produce any heat for what his use turns out to be very comfortable for the
2. actors the lamp head acts as a heat sink through its back part Surface can reach a temperature between the 50 C and the 80 C Please use protective gloves if you touch the lamp head at the heat sink Do not attempt to open any of the device or component housings To reduce the risk of electric shock do not remove lamp head or Control Unit cover No user serviceable parts inside Maintenance and repair work to be carried out only by THELIGHT Service Centre Do not cover the aluminium lamp head heat sink while using it Proper ventilation must be provided Avoid exposing the lamp head to the heat radiation of other light fixtures The lamp head is equipped with high power LEDs Due to their high light output intensity dont stare directly into the light source In order to protect against risk of electric shock the installation should be properly grounded Defeating the purpose of the grounding type plug will expose you to the risk of electric shock Marking CE TABLE OF CONTENTS ms e 3 Sci oe nn PP ee eo eee ee ees 4 5 Mal TE QGUP ES ii a 6 Components ANA accessories 7 Names 9 epee nn eee en ce ee ree ee ee ene eee ee 9 A N 9 ALONG lap ea ada 9 VAC Gontrol Un Eonia T E uated EE 10 Placing into opera lcd 11 Quick link swivel ball head mountin iii 11 Removing the Quick link swivel ball head MOUNTING 11 Connecting the power cable to the VAC Control Unit ceccseeeseteteteeseeceeeeees 12 Connectin
3. head will remain at the chosen setting When the lamp head is positioned at standard flat setting the light beam angle is 35 The maximum light beam angle is given when the lamp head is bend at its more convex setting Barn doors installation Place the barn door axle into the external lamp fa head segment grooves Then insert one end of 9 the axle into the hole located at the lamp head exterior segment as shown in the picture 6 The right mounting position is achieved when the Y product name is visible facing outwards Insert the other barn door axle end into the opposite hole located at the lamp head exterior segment 9 wWo gt 14y01 94y3 MMM 000000 17 Quick link diffuser installation To assemble the diffuser insert the four magnets in their respective holes to set up a diffusion box as shown in the picture o Position the lamp head in its standard flat setting a Align the top diffuser box magnets with their respective screws located on the lamp head Do the same thing with the low magnets and their power will automatically fix the diffuser to the lamp head The diffuser softens and broadens the light beam yet retains general beam shape with minimal colour temperature shift Excellent for softening harsh edges The transmission lost is 2 3 of a stop _ The diffuser has been designed so that when installed allows the lamp head to bend and NOTE focus the beam angle 18 8 SPECIFICA
4. En c 39 08197 Sant Cugat Validorew BARCELONA 93 589 3569 M n 608 691 65 ES www leproce corr una _EMC_ENB100048 NOTE Ths report ts an invisible document Pag 1 52 23 5 telproce Laboratorio de Ensayos marcado CE Test Laboratory CE mark S 55955 055000500500 4 See8eee8 e ere see reeeee ee o OOO OES cs SSS EE 2 Ma Mark Modelo 4LONG high power LED luminary VAC Control Unit Model SLIGHT high power LED luminary VAC Control Unit Description Seguridad ENSAYOS Y MEDIDAS EN 61 000 6 1 2005 TESTS AND MESUREMENTS EN 61 000 6 3 2005 Norma EN 61000 3 2 2001 42 2006 EN 61000 3 3 1997 42 2006 Sello de la compa a y firma Company seal and signature F J Garc a Ing T Telecom BARCELONA TEL 93 4802562 VOB oot 651 Av Ca N Enric 39 08197 Sant Cugat Validoreix BARCELONA SPAIN 93589 3569 Mov 608 691 651 O www telproce com O wow ermarcadoce com 24 WARRANTY THELIGHT high power LED light equipments are guaranteed to be free from defects in workmanship and parts in a warranty period of one 1 year from the date of purchase Defects that occur within this warranty period under normal use and care will be repaired or replaced at THELIGHT discretion solely at our option with no charge for parts or labour In the event of the equipment malfunction contact the dealer from which you purchased the product Please note that you wi
5. Mains powered LED fixtures AXUOKNYS GQUDGOHT QUOOOMD 6 DOSUVGMWI THELIGHT Lum and IV Si L INTRODUCTION This guide provides information about how to use the product functions to illuminate with this equipment as well as warnings on his use The 4LONG 4LIGHT and 6LIGHT are products of professional use for interior locations or studio and must be operated only by qualified technical personnel To obtain the maximum features please read the following operating instructions very carefully before using this fixture for the first time Please keep these operating instructions for you and subsequent users to reference in the future Safety Precautions Exemption from Liability Warranty www thelight com es THELIGHT Luminary for cine and TV S L For your own safety please read and follow all safety instructions and warnings THELIGHT Luminary for cinema and TV S L does not assume any responsibility for lighting failures caused by malfunction of this product The manufacturer disclaims liability for any damage to persons or property caused by inappropriate operation damage of this kind lies in the responsibility of the operator This product is manufactured to local specifications and the warranty is valid within the country of purchase Should the product fail or malfunction while you are abroad the manufacturer assumes no responsibility for servicing the product locally or bearing the expenditure incurred thereof
6. TIONS COLOUR TEMPERATURE LIGHT INTENSITY GREEN MAGENTA BIAS CRI DIMENSIONS WEIGHT POWER DRAW BEAM ANGLE LED RATED LIFE THELIGHT LED TECHNOLOGY RIGGING OPTIONS ACCESSORIES COLOUR TEMPERATURE LIGHT INTENSITY GREEN MAGENTA BIAS CRI DIMENSIONS WEIGHT POWER DRAW BEAM ANGLE LED RATED LIFE THELIGHT LED TECHNOLOGY RIGGING OPTIONS ACCESSORIES 4LONG adjustable from 2800K a 8500K with 100K increments dimmable with no colour deviation increments of 1 2 stop adjustable 1 4 y 1 8 steps 90 from 2900K a 6500K 622 x 207 x71 mm 4 4 kg 185W SOV maximum 220W variable from 30 to 65 standard 355 more than 90 000 hours UME Minimum Emitting Unit made up of 3 high power LED with a selected BIN Warm white White Green fresnel lens CPU control with THELIGTH software quick link swivel ball head adjustable yoke adjustable yoke to mount up to four units quick link diffuser box hexagonal 9 8 16mm baby spud removable barn doors 4LIGHT adjustable from 2800K a 8500K with 100K increments dimmable with no colour deviation increments of 1 2 stop adjustable 1 4 y 1 8 steps 90 from 2900K a 6500K 339 x20 x71 mm 2 4 kg 99W SOV maximum 120W variable from 30 to 65 standard 355 more than 50 000 hours UME Minimum Emitting Unit made up of 3 high power LED with a selected BIN Warm white White Green fresnel lens CPU control with THELIGTH s
7. alue 3 3 to 3300K and so on Push the button to increase colour temperature or push the button to decrease it lf you keep pushed any of the buttons the you will get a continuous variation _ Every push on the buttons will increase or decrease the colour temperature in calibrated NOTE increments of 100 Kelvin TURBO By activating the TURBO button a blue LED lights up on the screen of the Control Unit maximum light output is achieved in the colour temperature selected and the value 9 will appear on the dimmer display 14 DIMMER Light intensity variation The dimmer of the VAC Control Unit is totally digital and guarantees the regulation of light intensity without producing changes in the selected colour temperature Light intensity can be easily increased or reduced through the buttons located at the VAC Control Unit front panel Above them a digital display indicates the selected dimmer value from a minimum of 1 to a maximum of 9 Push the button to increase light intensity or push the button to decrease it If you keep pushed any of the buttons the you will get a continuous variation Every push on the buttons will increase or decrease the light intensity in calibrated LL increments of 2 stop GREEN Green magenta bias control Green magenta bias switch located at the VAC Control Unit front panel lets you easily alter the colour of the light emitting at any colour temperature towards green or magenta in increments
8. be set to DMX address 001 and it will automatically use the following four channels m If you wish to control several THELIGHT fixtures at the same values you will have to set them to the same address m If you wish to control several THELIGHT fixtures independently you will have to offset their address by 3 channels Example fixture1 address 001 fixture2 address 004 fixture3 address 008 DMX Channels When you connect your console to the VAC Control Unit you will be able to control THELIGHT fixtures through 3 channels Channel 1 start address 2 COLOUR TEMPERATURE From 2 8 to 8 5 from 2800kKelvin to 8500Kelvin Fader at O 2 3 means 2800Kelvin Fader at 100 9 9 means 8500Kelvin m Channel 2 start address 3 DIMMER Channel 3 start address 4 GREEN MAGENTA BIAS correction fader at 0 1 4 Green fader at 29 1 8 Green fader at 90 standard position green magenta at O fader at 70 1 8 Green fader at 100 1 4 Green THELIGHT luminaries DMX working personality can be configured to be recognised by Avolites consoles NOTE for Avolites Download the personality files to install into Avolites consoles from consoles users www avolitesdownload com PersonalityLibrary mainPage Main aspGID 3516 16 7 MECHANICAL ADJUSTMENTS Beam angle variation Hold the lamp head from the outer segments and bend it in or out to the wanted concave or convex shape Choose the light beam angle you need and the lamp
9. e connectors before inserting them Rotate the locking ring until it clicks into the lock position Connect the same way the other end of the extension cable in the input receptacle coming out from the lamp head Disconnecting the extension cable Grab the connector firmly turn the ring to unlock it and pull to extract tt NOTE The extension cable is provided with two equal connectors in every end both can be connected either in the VAC Control Unit or in the lamp head THELIGHT VAC Control Unit has been designed to supply power to the 4LONG the ALIGHT or the GLIGHT lamp heads With either of these connected the light emitted will always be correct 12 4 Placing the VAC Control Unit in the stand mast You can place the VAC Control Unit in the stand mast for a handy use close to the lamp head To do so you will need to use a regular Manfrotto or Avenger Super Clamp not included in the kit and insert the Hexagonal 9 8 16mm baby spud Once installed the hexagonal spud just slide the holder located at the VAC Control Unit bottom over the spud plate until properly seated as shown in the picture 9 Security cables The lamp head is provided with several holes specially design to insert one o more Smm snaps and their safety cable When the lamp head and any other component is mounted in a Warning hanging position it must be secured with a safety cable rated at a minimum of ten times the we
10. ead plate to the four rivets located at the back of the lamp head as shown in the picture On mounting the lamp head on any type of support tripod or ceiling Warning grid make sure the swivel ball head handle is facing down towards the ground Slide the swivel ball head plate until the four shoulder rivets drop into the receptacle The locking pin will snap into place when the plate Is properly seated proceeding to use the light fixture AN Warning Make sure the locking pin has totally entered in his housing before The standard swivel ball head comes with a 3 8 pin to be clamped into a grip head and allows the lamp head to be oriented and locked in a broad range of angles Removing the quick link swivel ball head Pull up on the locking pin and slide the swivel ball head plate until the four rivets get free Extract the swivel ball head by pulling it upwards 11 2 Connecting the power cable to the VAC Control Unit Connect the power cable to the plug located in the rear side of the VDC Control Unit Connect the power plug with a mains power outlet To avoid electric shocks and or damages in the equipment the Danger power switch located at the VAC Control Unit front panel must be off before connecting or disconnecting cables 3 Connecting VAC Control Unit and lamp head through the extension cable Connect the connector in the circular receptacle at the VAC Control Unit front panel Verify the correct alignment of th
11. g VDC Control Unit and lamp head through the extension cable 12 Disconnecting the extension cable cceccssssssssssssseecessssseeesseesssssesssssessenssseeenssssees 12 Placing the VDC Control Unit in the Stand MASt cccsssesecsssesesseseeseesesestsessnseessetens 13 SECUN CADES sron eE N 13 Digital Adjustment S audi lata 14 Turning the power ao 14 COLOR TEMPERATURE 14 O eee ee eee 14 DIMME N N A 15 RORE E Paa OI UP A eee ee eee ae ee ee eee 15 DMX 912 GONT Ol aiii a 16 Mechanical Adjustments 00 ccc cscescecssecsseseseessseesescessesecesensesensesensesenensasensanes 17 Beaniangle Varas 6 17 Bar doors dto 17 Quick link diffuser INSTANATION 18 v 9 16 tamil aldea 19 A eee ees E rene Sree ee eer ese eer eee eee eee 19 A nn E EEE EEA ET 19 SA E AE eee eee 20 Contro aa a E EEE E A EEEE 20 GAromaticiy coordinates diaria nai 21 PROCON ENIC OOO e 22 l 8 6 2 1c 6 ene ene eM tN 23 A cre tree ree ee ee ter eee eee ee eee 20 1 MAIN FEATURES ALONG 4LIGHT GLIGHT are LED panels housing a total of 192 high power LED 4LONG 96 high power LED GLIGHT 144 high power LED 6LIGHT They have been specially designed and their colorimetry calibrated for professional photography cinematography and television industry use THELIGHT luminaries main innovative features are e Variable Colour Temperature e Stable colour dimming e Green magenta bias control e Very high light output e Low power d
12. hey are compared with the reference illuminants These reference illuminants are the Planckian locus radiator set below SOOOK and the CIE daylight reference is set over 5000K The Planckian locus radiator references the chromaticity for several tungsten lamps colour temperatures while the daylight locus typify daylight type D illuminants The diagram evidence the light emanated by THELIGHT luminary at every colour temperature entirely matches with the described locus reference so that the colour of the light produced is essentially the same as incandescent and daylight It is also remarkable the minimum green magenta deviation over the locus reference along the range of colour temperatures means minimal difference between THELIGHT chromaticity coordinates and the ideal reference line CALIBRATION The Instrument Systems scanning spectrometer model Spectro 320 serial number 30932004 with its accessory TOP 100 has been calibrated according to the United States National Institute of Standards NIST and the german Physikalisch Technische Bundesanstalt PTB standard references ACCURACY The Instrument Systems scanning spectrometer model Spectro 320 serial number 30932004 with its accessory TOP 100 has an imprecision over the spectral radiometric results delivered lower than 1 specifications subject to change without notice THELIGHT technology is protected under Spanish license laws with international patents pending THELIGHT luminary for cine a
13. ight of the light fixture including its accessories 13 9 DIGITAL ADJUSTMENTS The VAC Control Unit doubles as power supply and digital remote controller of the following light parameters through Its programmed CPU e Calibrated Colour Temperature variation e Stable colour dimming e Green magenta bias control Turning the Power On Off Turn on the equipment by switching on the power button The light settings always remain stored when the VAC Control Unit is powered off Both the lamp head and the VAC Control Unit are electrically protected against power failures but to avoid possible electric shocks and or equipment damages make sure the power switch will be off before connecting or disconnecting cables In case of extreme over tension replace the 5mm 2 5Ah fuses from inside the fuseholder located at VAC Control Unit back See picture on page 9 If a power failure would happen or the cables would be accidentally disconnected the VAC Control Unit would entry on Error mode and the number 8 would show in the digital display To reset the equipment and resume the light values turn the switch power off connect the cables and switch on the power button COLOR TEMPERATURE Variation Colour temperature can be easily increased or reduced through the buttons located at the VAC Control Unit front panel Above them a digital display indicates at all times the selected colour temperature The value 3 2 corresponds to 3200K and the v
14. ll be not be reimbursed for the cost of bringing the equipment to the THELIGHT Repair Centre THELIGHT reserves the right to replace the product or relevant part with the same or equivalent product or part rather than repair it Where a replacement is provided the products or part replaced becomes the property of THELIGHT THELIGHT may replace parts with refurbished parts Replacement of the product or a part does not extend or restart the Warranty period Returns or exchanges from the customers will be accepted within 15 days of delivery and will not include the actual shipping costs Item s must be in original packaging and condition must not be assembled and must include its original user manual This warranty does not cover any damage resulting from Failure to follow the instructions in the instruction manual Repair modification or overhaul not conducted by any authorized THELIGHT personnel Hire natural disaster act of God lightning abnormal voltage etc Submergence in water flooding exposure to alcohol or other beverages infiltration of sand or mud physical shock or dropping of the equipment and other unnatural causes This warranty only applies to the lamp head and the Control Unit and not to the accessories such as the diffuser or barn doors nor does it apply to the fuses and other consumables provided Any consequential damages arising from failure of the equipment such as expenses incurred in taking pictures
15. luminaries could be used together with other light sources THELIGHT has accurately calibrated both the CCT and the chromatic coordinates to match them with traditional light sources following tungsten and daylight standards The digital Control Unit allows a further and precise green magenta correction along the whole scale of colour temperatures 2 COMPONENTS AND ACCESSORIES Each THELIGHT kit is composed by 1 x 4LONG 4UGHT GUGHT lamp head 1 x VAC Control Unit waste 1 x Quick link swivekball head with 3 8 pin 2 x Removable barn doors 1 x 2 0 meters power cable Ke 1 x Hexagonal 5 8 16mm baby spud 1 x Quick link diffusser 3 NAMES AND PARTS LIGHT lamp head Rear view rivets for swivel ball head mount input cable and connector 4LONG lamp head Rear view rivets for swivel ball head mount input cable and connector VAC Control Unit Front view Rear view OONA WN gt 1 2 3 4 Power switch Colour temperature digital display Intensity level digital display Turbo status blue LED Green magenta offset status green LED Power output Colour temperature adjustment buttons Intensity adjustment buttons On off turbo button Green magenta knob XLR DMX input Mains power input XLR DMX out Fuse receptacle 2 x 2 04 10 4 PLACING INTO OPERATION 1 Quick link swivel ball head mounting Align the swivel ball h
16. nd tv S L www thelight com es 21 PHOTOMETRICS Lux 10000 1600 Lux 9500 740 Lux 9000 1100 9600K F Stop 22 8 2 9600K F Stop 16 5 6 9600K F Stop 16 7 5 6 7 Fc 930 149 Fc 910 69 Fc 836 102 24 fps 500 ASA 4LONG meters 4LIGHT meters 6LIGHT meters Fc 650 102 Fc 418 96 Fc 632 78 3200K F Stop 16 4 5 6 7 3200K F Stop 11 7 3200K F Stop 16 3 5 6 3 www cd6 upc edu Lux 7000 1100 Lux 4500 600 Lux 6800 840 Readings made with scanning spectrometer at stable temperature Control Unit set at maximum light intensity Turbo On and dimmer at 9 setting lamp head at standard flat setting and measurement instrument positioned perpendicular over the luminary surface center CALIBRATION The Instrument Systems scanning spectrometer model Spectro 320 serial number 30932004 with its accessory TOP 100 has been calibrated according to the United States National Institute of Standards NIST and the German Physikalisch Technische Bundesanstalt PTB standard references ACCURACY The Instrument Systems scanning spectrometer model Spectro 320 serial number 30932004 with its accessory TOP 100 has an imprecision over the spectral radiometric results delivered lower than 1 Specifications subject to change without notice THELIGHT technology is protected under Spanish lice
17. nse laws with international patents pending THELIGHT luminary for cine and tv S L www thelight com es 22 REGULATIONS This equipment is designed to meet the following regulations and safety standards for battery powered technology equipment ENVINRONMENTAL THELIGHT devices are certified and intended for indoor use lamp head IP21 VDC Control Unit IP41 LAMP HEAD OPERATI N TEMPERATURE from 20 to 30 C CONTROL UNIT OPERATION TEMPERATURE from 20 to 502 C OPERATING HUMIDITY from 30 to 90 RH non condensing FUSE 2x2 0A Testn 2010 790 Date 27 9 2010 Mark THELIGHT 2 Models Serial n s n REPORT ELECTROMAGNETIC COMPATIBILITY Test Laboratory CE mark Aia AN me E AA TESTS AND MEASURES REQUESTED DIRECTIVE 2004 108 CE Electromagnetic Compatibility E M C STANDARD IEC EN 61000 6 1 2005 Electromagnetic compatibility Generic immunity standard Residential and light industry EC EN 61000 6 3 2005 Electromagnetic compatibility Generic EMI standard Residential and light industry EN 301489 1 v1 8 1 2008 02 Radio Electric Spectrum Protection 1 6 GHz Band EC EN 61000 3 2 2001 A2 2006 Harm onic current emissions a c Mains EC EN 61000 3 3 1997 42 2006 Voltage fluctuations and Flicker a c Mains UNE EN 5015 2007 A1 2008 42 2008 EMI of electrical lighting and similar equipment CISPR 15 2005 AY rif mo A F 4 Garqin ao Eng yor T Av Ca N
18. of 1 8 and Ya When this switch ts not in the standard position a green LED light turns on in the VAC Control Unit to warn that the light emitted no longer guarantees the correct chromaticity THELIGHT guarantees the correct colorimetry for light emitting from their high power LED light fixtures calibrated in the laboratory according to current international standards of the CIE 13 3 1995 for the average CHI and the chromatic co ordinates x y CIE 1931 This certifies that our luminaries have no green magenta deviation 15 6 DMX 512 CONTROL THELIGHT lightning fixtures have been designed for a full DMX control from the 5 pin DMX port located at the back of the VAC Control Unit Connect the DMX cable coming from your console into the DMX IN male connector located at the back fo the VAC Control Unit Beside the DMX IN there is also a DMX OUT connector to daisy chain fixtures Adressing channels Push both and COLOR TEMPERATURE buttons at the same time and then switch on the power button Wait a few seconds for the three digital displays to blink Now you can define the start address To do so just push the or DIMMER buttons to increase or decrease the first fixture address Once you have chosen the desired address number push the TURBO button to save the selection Keep in mind the following points regarding DMX control THELIGHT DMX protocol uses 3 channels per fixture The first fixture to be controlled should
19. oftware quick link swivel ball head adjustable yoke quick link diffuser box hexagonal 9 08 16mm J baby spud removable barn doors 19 COLOUR TEMPERATURE LIGHT INTENSITY GREEN MAGENTA BIAS CRI DIMENSIONS WEIGHT POWER DRAW BEAM ANGLE LED RATED LIFE THELIGHT LED TECHNOLOGY RIGGING OPTIONS ACCESSORIES OLIGHT adjustable from 2800K a 8500K with 100K increments dimmable with no colour deviation increments of 1 2 stop adjustable 1 4 y 1 8 steps 90 from 2900K a 6500K 339 x 302 x 71 mm 3 0 Kg 140W SOV maximum 165W variable from 30 to 85 standard 355 more than 50 000 hours UME Minimum Emitting Unit made up of 3 high power LED with a selected BIN Warm white White Green fresnel lens CPU control with THELIGTH software quick link swivel ball head adjustable yoke quick link diffuser box hexagonal 9 8 16mm J baby spud removable barn doors VAC Control Unit DIMENSIONS WEIGHT POWER SUPPLY INPUT FREQUENCY OUTPUT FREQUENCY FUSE 334 x 173 x87 mm 2 kg Universal 90 264 VAC 90 60Hz 20KHz 2x 2 0A 20 CHROMATITY COORDINATES DIAGRAM x y CIE 1931 x vs y planckian locus Tc lt 5000K daylight Tc gt 5000K 0 8 535 e xvsy THELIGHT 0 2 0 1 0 0 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 0 8 X shown on the diagram are the THELIGHT lamp head chromaticity coordinates x y CIE 1931 feed and digitally controlled by its Control Unit and t
20. or recording images or loss of expected profit will not be reimbursed whether they occur during the warranty period or not Parts essential to the servicing of the light equipment that is components required to maintain the functions and quality of the fixture will be available for a period of five years after the product is discontinued THELIGHT Luminary for cine and tv S L www thelight com es The total or partial reproduction of this guide is prohibited without the express written permission of THELIGHT THELIGHT technology is protected under Spanish license laws with international patents pending Information and specifications in this document are subject to change without notice 2011 6 Copyright THELIGHT All rights reserved 20 OOOOO0OOOQ THELIGHT Luminary for cine and TV S L www thelight com es 2011 Copyright THELIGHT All rights reserved 26
21. raw e High CRI digitally calibrated light e Lightweight lamp head NOTE ABOUT MEASURING COLOUR TEMPERATURE CCT ALONG 4LIGHT BLIGHT incorporate the innovative THELIGHT technology based on high power LED triplets Warm White White Green fresnel lens CPU control software to obtain the wide range of calibrated colour temperatures combined with a high colour rendering index CCT We must remark that colour meters in use today are designed for a full spectrum source such as Incandescent lights and therefore cannot be used to accurately read the correlated colour temperature CCT of the light emitted by THELIGHT and other LED light fixtures The eventual diversions to green display as CC10M or CC15M in hand held colour meters are due to these unaccuracy on reading of the light emitted by LED and must not be considered THELIGHT guarantees pure white light and correct colorimetry of the light delivered by its high power LED luminaries which have been calibrated in laboratory according to CIE 13 3 1995 international standards for measurement of the CRI and chromatic coordinates x and CIE 19371 The reliability of this digital equipment is supported by the calibration THELIGHT has made in laboratory by spectrophotometer which precision is half yearly calibrated according to the National Institute of Standards NIST of the United States and of the Physikalisch Technische Bundesanstalt PTB of Germany In order that the advanced THELIGHT