Home
Entry Line Ethernet VDSL Extender User's Manual
Contents
1. Specifications Applicable Standards IEEE802 3 10Base T IEEE802 3u 100Base TX Ethernet over VDSL Fixed Ports 1 x 10 100Mbps Ethernet port with RJ 45 connector 1 x Ethernet over VDSL port with RJ 11 and Terminal Block connectors Speed 10Base T 10 20Mbps for half full duplex 100Base TX 100 200Mbps for half full duplex Ethernet over VDSL 1 3 5 10 15 20 25 30 40 50Mbps Switching Method Store and Forward Forwarding rate 14 880 148 810pps for 10 100Mbps Cable 10Base T 100Base TX Ethernet over VDSL 2 pair UTP STP Cat 3 4 5 up to 100m 2 pair UTP STP Cat 5 up to 100m Cross over telephone wires LED Indicators Per Unit 3 LEDs Power1 Power2 Power3 Per Port RJ 45 2 LEDs Link ACT FDX RJ 11 Terminal Block 9 LEDs Remote Local Error Link 1 2 3 4 5 Dimensions 50mm W x 110mm D x 136mm H 1 97 W x 4 33 D x 5 35 H Weight 0 8Kg 1 76lbs Terminal Block 12 30VDC Power DC Jack 12VDC External AC DC required Operating Voltage amp Max Current Consumption 0 225A 12VDC 0 113A 24VDC Power Consumption 2 7W Max Operating Temperature 34 74 C 29 F 165 F Storage Temperature 40 85 C 40 F 185 F Humidity 10 95 non condensing Safety UL60950 EN60950 IEC60950 Emissions FCC Part 15 Class A CE EN61000 6 2 EN61000 6 3 MICROSENS GmbH am
2. 16 D 59067 Hamm Germany Tel 49 0 94 52 0 Fax 49 0 94 52 100 MICROSENS Hardened VDSL Ethernet Extender User s Manual Page 8 Connecting to Power Redundant DC Terminal Block Power Inputs or 12VDC DC Jack 12VDC DC Jack Step 1 Connect the supplied AC to DC power adapter to the receptacle on the topside of the Hardened VDSL Ethernet Extender Step 2 Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage Redundant DC Terminal Block Power Inputs There are two pairs of power inputs can be used to power up this device You only need to have one power input connected to run the Hardened VDSL Ethernet Extender Step 1 Connect the DC power cord to the plug able terminal block on the Hardened VDSL Ethernet Extender and then plug it into a standard DC outlet Step 2 Disconnect the power cord if you want to shut down the Hardened VDSL Ethernet Extender Power Input Assignment Power 1 12VDC DC Jack 12 30VDC Power2 Power Ground 12 30VDC Terminal Power3 Block Power Ground Earth Ground DIP Switch Assignment Loc The device operates in local mode Rmt The device operates in remote mode MICROSENS GmbH amp Co KG Kueferstr 16 D 59067 Hamm Germany Tel 49 0 94 52 0 Fax 49 0 94 52 100 MICROSENS Hardened VDSL Ethernet Extender User s Manual Page 9
3. 9 0 94 52 100 MICROSENS Hardened VDSL Ethernet Extender User s Manual Page 7 Installation This chapter gives step by step installation instructions for the Hardened VDSL Ethernet Extender Selecting a Site for the Equipment As with any electric device you should place the equipment where it will not be subjected to extreme temperatures humidity or electromagnetic interference Specifically the site you select should meet the following requirements The ambient temperature should be between 34 to 74 degrees Celsius The relative humidity should be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards Make sure that the equipment receives adequate ventilation Do not block the ventilation holes of the equipment e The power outlet should be within 1 8 meters of the product DIN Rail Mounting Fix the DIN rail attachment plate to the back panel of the Hardened VDSL Ethernet Extender Installation Place the Hardened VDSL Ethernet Extender on the DIN rail from above using the slot Push the front of the Hardened VDSL Ethernet Extender toward the mounting surface until it audibly snaps into place Removal Pull out the lower edge and then remove the Hardened VDSL Ethernet Extender from the DIN rail o o L w o VJ MICROSENS GmbH amp Co KG Kueferstr
4. MICROSENS Entry Line Ethernet VDSL Extender User s Manual 11 Mies MUI a 8s 5 G 40Mb gt b SOMbps Ethernet VDSL Extender MICROSENS Hardened VDSL Ethernet Extender User s Manual Page2 Preface This manual describes how to install and use the Hardened VDSL Ethernet Extender The Hardened VDSL Ethernet Extender introduced here provides one channel for Ethernet over VDSL The Hardened VDSL Ethernet Extender fully complies with IEEE802 3 10Base T and IEEE802 3u 100Base TX FX standards In this manual you will find Product overview Features on the Hardened VDSL Ethernet Extender Illustrative LED functions Installation instructions Specifications MICROSENS GmbH amp KG Kueferstr 16 D 59067 Hamm Germany Tel 49 0 94 52 0 Fax 49 0 94 52 100 MICROSENS Hardened VDSL Ethernet Extender User s Manual Page 3 Table of Contents Preface 1 Table of Contents 3 Introduction Product Overview Product Features Packing List One Channel Hardened VDSL Ethernet Extender Ports VDSL Mode Settings DIP switch Front Panel amp LEDs Installation Selecting a Site for the Equipment DIN Rail Mounting Connecting to Power O ONN N n 5 A Specifications MICROSENS GmbH amp Co KG Kueferstr 16 D 59067 Hamm Germany Tel 49 0 94 52 0 Fax 49 0 94 52 100 MICROSENS Hardened VDSL Ethernet Extender User s Manual Page4 Introductio
5. er 3 Ethernet Steady A valid Ethernet connection established Flashi Transmitting or receiving Ethernet data Link A ng stands for ACTIVITY Neither valid Ethernet connection Off established transmitting receiving Ethernet data Steady Ethernet Connection in full duplex mode FDX FDX stands for FULL DUPLEX Off Ethernet Connection in half duplex mode Ethernet over VDSL The VDSL port transmitting receiving at 1Mbps up to 1900M The VDSL port transmitting receiving at 3Mbps up to 1800M The VDSL port transmitting receiving at 5Mbps up to 1600M The VDSL port transmitting receiving at 10Mbps up to 1400M The VDSL port transmitting receiving at 15Mbps up to 1200M The VDSL port transmitting receiving at 20Mbps up to 1000M The VDSL port transmitting receiving at 25Mbps up to 800M The VDSL port transmitting receiving at 30Mbps up to 700M G The VDSL port transmitting receiving at rgen 40Mbps up to 600M The VDSL port transmitting receiving at 50Mbps up to 300M Green Amber Green Amber Green Amber Green Amber Amber Remot Steady The device operates in remote mode Local Steady The device operates in local mode Error Steady Error occurred Link Steady A valid VDSL connection established MICROSENS GmbH amp Co KG Kueferstr 16 D 59067 Hamm Germany Tel 49 0 94 52 0 Fax 4
6. ing items immediately to our authorized reseller The Hardened VDSL Ethernet Extender UsER s MANUAL AC to DC Power Adaptor and Power Cable optional MICROSENS GmbH amp Co KG Kueferstr 16 D 59067 Hamm Germany Tel 49 0 94 52 0 Fax 49 0 94 52 100 MICROSENS Hardened VDSL Ethernet Extender User s Manual Page 5 One Channel Hardened VDSL Ethernet Extender Ports The Hardened VDSL Ethernet Extender provides one TX port and one VDSL port For the TX port it uses RJ 45 connector and auto senses the speed of 10 100Mbps For the VDSL port it uses RJ 11 and Terminal Block connectors and auto senses the speed of 1 3 5 10 15 20 25 30 40 50Mbps VDSL Mode Settings VDSL mode settings are made very simple by means of a DIP Dual Inline Package switch on the top panel of the Hardened VDSL Ethernet Extender DIP switch There is one pin on the DIP switch for VDSL mode settings Refer to the table below for more details Loc Rmt The device operates in The device operates local mode remote mode MICROSENS GmbH amp Co KG Kueferstr 16 D 59067 Hamm Germany Tel 49 0 94 52 0 Fax 49 0 94 52 100 MICROSENS Hardened VDSL Ethernet Extender User s Manual Page 6 Front Panel amp LEDs LED Indicators The LED indicators give you instant feedback on status of the Hardened VDSL Ethernet Extender LEDs State Indication Power Steady Power 1 Power 2 Off Power off Pow
7. n The Hardened VDSL Ethernet Extender provides one channel for Ethernet over VDSL This Hardened VDSL Ethernet Extender solution is perfectly fitted in the industrial applications or rugged environment Product Overview Product Features Meets NEMA TS1 TS2 Environmental requirements such as temperature shock and vibration for traffic control equipment Meets IEC61000 6 2 EMC Generic Standard Immunity for industrial environment Operates transparent to higher layer protocols such as TCP IP Ethernet Port Supports IEEE802 3 802 3u 802 3x Auto negotiation 10 100Mbps full half duplex Auto MDI MDIX VDSL port Symmetrical on the VDSL high speed full duplex 50Mbps communications link over existing copper telephone line OneDIP switch for configuring Local Loc and Remote Rmt Ten speeds with speed indicator LEDs on front panel of unit up to 50Mbps about 300meters 984ft down to 1Mbps about 1 900meters 6 233ft Operating voltage and Max current consumption 0 225A 12VDC 0 113A 24VDC Power consumption 2 7W Power Supply Redundant 12 30VDC Terminal Block power inputs 12VDC DC JACK with 100 240VAC external power supply Operating temperature ranges from 34 to 74 Supports Din Rail Panel or Rack Mounting installation Packing List When you unpack this product package you will find the items listed below Please inspect the contents and report any apparent damage or miss
8. p Co KG Kueferstr 16 D 59067 Hamm Germany Tel 49 0 94 52 0 Fax 49 0 94 52 100 MICROSENS Hardened VDSL Ethernet Extender User s Manual Page 10 Standards ESD Standard EN61000 4 2 Radiated FRI Standards EN61000 4 3 Burst Standards EN61000 4 4 Surge Standards EN61000 4 5 Induced RFI Standards EN61000 4 6 Magnetic Field Standards EN61000 4 8 Voltage Dips Standards EN61000 4 11 Environmental Test Compliance Vibration Resistance IEC60068 2 6 Shock IEC60068 2 27 Free Fall IEC60068 2 32 NEMA TS1 2 Environmental requirements for traffic control equipment MICROSENS reserves the right to make any changes without further notice to any product to improve reliability function or design MICROSENS does not assume ary liability arising out of the application or use of any product FR 1708 MICROSENS GmbH amp KG Kueferstr 16 D 59067 Hamm Germany Tel 49 0 94 52 0 Fax 49 0 94 52 100